ML20010F988

From kanterella
Jump to navigation Jump to search
LER 81-019/03L-0:on 810728,during Surveillance to Prove Operability of Diesel Generator 1,fuel Supply Hose Developed Leak.Caused by Excessive Localized Flexure & Vibration. Hose Replaced
ML20010F988
Person / Time
Site: Cooper Entergy icon.png
Issue date: 08/25/1981
From: Freborg S
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20010F973 List:
References
LER-81-019-03L, LER-81-19-3L, NUDOCS 8109150192
Download: ML20010F988 (1)


Text

s 5 O R '.9 366 U S PSUCL E AR R[ GUL AT ORV COMMi%IO*3 LICENSEE EVENT REPORT cont w eLoc< l l I I 1  !  ;@ (Pd ASE PRINT OR TM An REQUIRED INFORMATIOM lo ! 18 9l l N !LICENSEE 7

E l CCOCE l P l R l l l@l le IS 010 l -l O l 0 l 0 l 010 l - l 0 l250 l@l L8CE N$E NUUeE H 2b 4 LIC5 l 111  ! Il 1l@l?? LATl Setl@

%E 1 vPE JO CON i klM 4 s[RN 60l L hl 61Ol 5 l Ol 010 l 219 l 8MI O l 7EVENT l 2 DlATF 318 l 1 @l o l RE 8 PORT l 215l 8 l 80l l@

7 DOCK E T NUVB E R 68 69 74 75 D ATE EVENT DESCRIPTION AND PROBABLE CONSEQUECES h

[U R l Durimg nerformnce of Sitveillance Proceitre 6.3.12.1 to prove operability of #1 DG I

[ol3l l prior to making "B" loop of containment cooling subsystem inoperable for maintenance,l l o 14 I I a fuel supply hose developed a leak. #1 DG was shut down and declared inoperable. j l o I s l [Survc.illance procedures per RTS 4.5.F.1 were commenced. This event is not repetitive.l 10 !6 I l There were no cdverse ef fects c- theyublic health and safetv. I lo I7l l l lolo i l l SYSTEV C A US E CAUSE COMP VALVE CODE CODE SU8COCE COVPONENT CODE SU8CCOE SueCCDE lo191 i El Elh Wh l Blh lE lN lG lI lN lE lh lZ lh j h 7 8 9 10 11 12 13 TM 19 20

,_ SE QUE NTI AL OCCUR N E NCE REPORT REVISION LE R EVENTvEAR REPORT NO CODE TYPE NO.

O g. AO a; 1811l

_ 21 22

[-l 23 l0l1l9l 24 26 l/l 27 l 0l 31 28 2')

l Ll 30

[--J 31 W

32 TAKEN A T ON ON PL ANT T HOURS S B IT D FOR UW St PPLI MAN FACTU5ER l33A l@l34F l@ lZl@

3b l2l@

36 l0l0l0l0l 31 40

(_' j @

41 l

4]

l@ lAl@

43 l44C l 6 l 3 l 441 l@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h li10ll Fuel supply hose (Part #2-01H-003-042) developeu a leak due to excessive localized I i i [ flexure and vibration. Fuel supply hose was replaced restoring #1 DC tO normal oper- I g1 ;,;l ability. Fuel hose will be rerouted during outage to alleviate excessive flexure. l FTRI I li I A Il 1 a 9 80

$ s " POWER OTHE R ST A TUS I CO RY DISCOV E RY DESCRIPTION l1 15l W h l0l9l0lhl NA l (,B j h C Surveillance Testing

_ l OC TIVI T Y CONTENT RE LE ASE D OF.RE L E ASE AVOUNT OF ACTIVITY LOCATION OF ret E ASE l1 l f> I d h [,1,,j@l NA l 1 NA _

l 7 8 9 10 11 44 45 80 F' '4 SONNE L F x POSv A ES NUYRE R TYPE DESCRIPT:ON l' i 171 1 01 O l' Ol@[z_J@l NA  !

PE RsONNE L ,NJu'AS Nov.,A DESCR,PTiONh D !, I l ol ol ol@l H *a n I 11 12 80 1 (M f)f ()H Dan.* 4 UE Tf1 F ACit I T V TVP! I;f $L HIP f DON l'I9Il.ljhl NA l Pon , u , , , 81091501'2 810825

,. o, oni.,PwaQ') PDR ADOCK 05000299 NH(. UM OM V ,

! > I "I Lsf,61 n S PDH l llllllltl[ tl l}

p 3 in tH 69 8 0 . ".

N A'.'E OF PR E P A R E Fi SCort S.

Freborr. psoye 402-825-3811 E, t