05000298/LER-1980-047-03, /03L-0:on 801117,RHR Loop a Suppression Pool Cooling Inboard Throttle Valve Found Inoperable.Caused by Key Failure Between Motor Pinion Gear & Shaft Due to Wrong Key Matl Installed.Motor,Pinion Gear & Key Replaced

From kanterella
(Redirected from ML20004D579)
Jump to navigation Jump to search
/03L-0:on 801117,RHR Loop a Suppression Pool Cooling Inboard Throttle Valve Found Inoperable.Caused by Key Failure Between Motor Pinion Gear & Shaft Due to Wrong Key Matl Installed.Motor,Pinion Gear & Key Replaced
ML20004D579
Person / Time
Site: Cooper 
Issue date: 12/16/1980
From: Doan P
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20004D558 List:
References
LER-80-047-03L, LER-80-47-3L, NUDOCS 8106090549
Download: ML20004D579 (1)


LER-1980-047, /03L-0:on 801117,RHR Loop a Suppression Pool Cooling Inboard Throttle Valve Found Inoperable.Caused by Key Failure Between Motor Pinion Gear & Shaft Due to Wrong Key Matl Installed.Motor,Pinion Gear & Key Replaced
Event date:
Report date:
2981980047R03 - NRC Website

text

__. _ _-._. - _ _ - - _ - - _ - _ _ _ _ _ _ -

l myP

/"

e U. S. NUCL E A" CEGULATORY COMMISSION j

LICENSEE EVENT REPORT l'

CONTROL 8L)CK: l l__l l

l 1 lh

,(PLEASE PRINT OR TYPE ALL REQUIRED INPORMATION) s 1

D l Nl El Cl Pl d lj@l d d -l 0l ol Cl 0l -l Ol d d@l 4 l ll il 1l 1l@l l

l@

s e LsCENSEE COOg to 15 LsCENSE NUMet A 25 2s LiC6NSE Tvrt 40 5 7 CA T 58

'T 3

% l @l 0 l 5 l 0 l 0 l 0l 21 91 8)@l 1 l 1 l 1 I 7 l 8 I o @l il 21 11 d d d@

8 60 89 00CEST NuMSE A 88 SS EVENT DATE 74 IS AEPORT DATE 40 EVENT OESCRIPnON AND PROSA8LE CONSEQUENCES h H lWhile in Cold shutdown, RHR-MO-34A, the RHR "A" Loop suppression pool cooling in-1 y lb:ctd throttle valve would not operate. This is a repetitive occurrence (ref. LER

{

D l76-14, 77-11 & 80-30). The"B"RNRk.oopwasoperableaswellasbothdieselcener-l D lators. The upstream valve was ooerable so that the "A" Looo could be used for LPci I

] 14n p,.c4nn pur,n.. nun un_p a n41.a 4,

4.

m e -,3_ i7 l s

,na pne

..nn e,4 nm.n e 4.ni,*4mn

.] lcloced position. There were no adverse affects to the public health and safety.

l gl (RTS 3.5.3)

I a

~

4 COE Su C E COMPONE NT CODE Sue OE SU E

D I cI Fl@ l_sj@ W@ l vl Al Ll VI ol Pl@ l Al@ W @

e e

to il 12 la 18 19 20 SEOuf NTI AL OCCuRRENCf REPORT REVIS80N l

LEmino EVENTvtAm R EPORT No.

COOG TYPE NQ,

@ 4,Eg I 81 01 l-J l 01 41 71 M

l of 31 L.tj 1--J W

21 22 23 24 26 3r iS 21 30 21 32

?A#" '?clic e"!ST

'Of7Bi%"

LAJ@Lxl@

Lz_l@

L7J@

l of of o@l of ^Us*"n',#3.. 'Tu"A50'

.A,t'IfCTu",TE.

Nouas L.d@

l l@

LLJ@

lti210l0l@

n as as v

ao

<a na a

u

<r CAUSI Od5CSIPTION AND CORRECTIVE ACTIONS 27 g [Op2rator is Limitorque SMB-4. Event due to key failure between motor pinion gear

[

] land shaf t. Motor,. pinion gear, and key were replaced. Analysis of key by Limitoroue I g l indicated they installed the wrong key material. Manufacturer to review operators l

] I cupplied to generate a list that required other than standard key. An updated LER l

] l will report sar.pling procedure and inspection results based on Limitorque's respons9

's'r AE oTNEnsTATus @"'sEoNa5 C'

] l_G,,,,J@ l 010 l 0 j@l NA l

IAl@l Operator Observation @

sPOwEn i

oiscovEnv of scniPTieN l

' ITiviTy Co'0 TENT

) 1 Z } h U@{ _

AMOUNTQF ACTIVITY @ l LOCATION OF RELEA$E @

A i

TELEAsE3 QF RELEASE i

NA 1

NA l

8 9 to 33 e4 e6 go PELSONNEL DPO$uRES I

NUMSE R TYPE C ESCRIPTION

-] I o f o f ol@LIJ@l u

I

,E:sO NEL,mu'4Es otsC,rioN@

nom E.

] l O I O I Ol@l NA l

i, t uss OF One OAMACE TO F ACIL8TY TYPE OE SCitIPflOas D LtJ@l NA I

0-9 to go 0 Luld*EMGletPTIO88 on. uE e

NA d l

l l l l l l l l l l j l l {'

g*10 6 0 9 0 $% '

o' "5

NAME OF PREPARER f

PHONE: