05000289/LER-1978-003-03, /03L-0:on 780112,emergency Diesel Generator 1B Failed to Start on Simulated Test Signal During Procedure SP1305-5.2.Caused by Drifting Oil Pressure Limit Switch. Setting Adjusted,New Limit Switch Ordered

From kanterella
(Redirected from ML19261F263)
Jump to navigation Jump to search
/03L-0:on 780112,emergency Diesel Generator 1B Failed to Start on Simulated Test Signal During Procedure SP1305-5.2.Caused by Drifting Oil Pressure Limit Switch. Setting Adjusted,New Limit Switch Ordered
ML19261F263
Person / Time
Site: Crane Constellation icon.png
Issue date: 02/03/1978
From: Herbein J
METROPOLITAN EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19261F262 List:
References
LER-78-003-03L, LER-78-3-3L, NUDOCS 7910250702
Download: ML19261F263 (2)


LER-1978-003, /03L-0:on 780112,emergency Diesel Generator 1B Failed to Start on Simulated Test Signal During Procedure SP1305-5.2.Caused by Drifting Oil Pressure Limit Switch. Setting Adjusted,New Limit Switch Ordered
Event date:
Report date:
2891978003R03 - NRC Website

text

NRC 8,ORM 066 U ^ NUCLEAR REGULATORY COMMISSION

.CENSEE EVENT REPORT CO,NTACL BLOCK: l l

l l

l l

l (PLEASE PRINT OR TYPE ALL REQUIREO INFORMATIONI i

s o li i v1 :I -l yl l il@lo lo l 10 lo lo lo lo I 10 lo l@l hl il il il il@l I

l@

7 8 9 LICENSEE COOE 14 15 LICENSE N6V8ER 25 26 64 CENSE TY PE JJ 57 OA T $4 CON'T

$c7RCE Il hl0 l 51010 l01213 lo @l0 l1 l112 l' l3 @l012 l0 l 317 l8 l@

0 8

60 61 QCCKgT NLV8ER 64 69 EVENT 0 ATE 74 75 REPORTDATE

$3 EVENT DESCRIPTION AND PROB ABLE CONSECUENCES o

2; l Energency Diesel Generater I3 faile

.c start en a si=ulated auto IS test signal dur-ing the first test of Actuation 3 Test Group i HFI/L?! Lcgic per SF1305-5 2 Sis g

3 event is reportable per Technical Specification 6.9 2.3(2).

Since redundant scurces of offsite power vere available and IG-?la was operable, no threat to the health and 3

safety of the public resulted. Se diesel was success uily started en a repeat of e

the IS test signal, and en all subsequent tests. Cther events of this nature: Th-13 a

7 g

o a l I

60 7

8 3 SYSTEM

CAUSE

CALSE COMP.

VA LV E CODE CCCE SL8COCE COMPCNENT CODE SUSCOCE SU8C00E IIl Elh I3 I

I I h h bl h I

i lhh O

9 7

8 9

10 11 12 13 18 19 20 S E CL E N TI AL OCOURRENCE REPCRT REV'S CN lea no EVENT YEA R RE' ORT NO.

COCE TYPE Ns.

@Nggg

'21718I 1-1 o l0 13 I

- 1 In l, I Ld 1-1 Ld a

22 23 24 26 27 28 23 30 31 32 ACTION sVTumE EPPECT SHUTOCWN ATTACHMENT N P R O-4 PRIVE COMP.

COMPCNENT TAKEN ACTION ON PLANT METHOO HOURS SL8MITTED PORMb68.

SUPPL;ER MANUPACTURER l E lgl34D lg

]35Z [g gg l1 0lol0 ol [jrJ g h l g W g l, lc lg b lg 33 36 3

40 41 42 43 44 47 CAUSE OESCRIPTION AND CCARECTIVE ACTICNS h l The oil pressure linit switch foPLSI cressr-- s.& M*+.a o

,7 i

e, ~ nn a +. --

i o

which cause:i the diesel to trin. Se settir e

<.,3

,~,.,..a to 3 esieto trovo+

e.-....

l occu.rrences of this type until a replacement CFLS is received. Sressure rance: 1 ei 25 psi; Pressure Diff.: 2 to lo psi; Senser type: 3elleys, gaterta- ?hesther 3ren:-J

Elect. Svitch
15A 1125 VAC 60 h:: and 0.5A 2125 VOC; Cat. :Ic. 21A13LO253-3.

I 7

3 3 80 P ACILITV ME*HCDCP ST UVS

% PCWER OTHER STATUS OtSCOVERY CISCOVERY OESCRIPTICN 1 0 I ^ l@ 1 1 1 0 l@l 27^

l 12 l@l:IA I

i s

7 8 9 to 12 13 44 45 46 80 ACTIVITY CONTENT RELEASED OPRELEASE AMOUNT QP ACTivlTV LOCATION CP RELEASE 1

6 l

l l

?IA l

we 7

8 9 to 11 44 45 30 PER$0NNEL EXPCSLRES NUM8ER TYPE O E SC RIPTION 1010101@l l@l n

.m.

07G I

i 7

{hD\\

(I J B0 7

8 9 11 12 13 PlascNNE L.N;LRi ts NUV9ER OESCRIPTICN I Cl Cl Cth M

i 1

3 7

8 9 11 12 30 LOSS CP CR O AM AGE TO PACILITY TV'E O E SC *l**1C N I

3 (

Ik 7

4 9 10 30 PV8L'CITV NRC USE CNLY

.SSUED DESCRtPTION 2

0 Y

'le *21*? " aW =alaa 39 l

ll ll llll ll l l lg 7

3 9 to 68 69 30,

NAME OF PREPARER

- I E*V"P3 PHCNE: -

'91oas 70R