EVALUATION OF LICENSEE' S CCMPLIANCE WITH THE NRC CRDER CATED MAY 16, 1979 TOLEDO EDISCN CCMPANY AND THE CLEVELAND ELECTRIC ILLUMINATING CCMPANY DAVIS-BESSE NUCLEAR DC%ER STATION, UNIT No. 1 OCCXET NO. 50-346 INTRCCUCTICN Sy Order dated May 16, 1979, (the Order) tne Toleco Ecison Comoany and tne Cleveland Electric Illuminating Company (TECO or the licensee) were dir2cted by tne NRC to take certain actions with respect to Davis-Sesse Nuclear Pcwer Station, Unit 1 (CB-1).

Prior to this Order and as a result of a preliminary review of the Three Mile Island, Unit No. 2 (TMI-2) accident, the NRC staff initially icentified several numan errors that contributed significantly to the severity of the event. All holders of coerating licenses were sucsequently instructed to take a numcer of immediate actions to avoid repetition of these errors, in accordance with bulletins issued by the Commission's Office of Insoection and Enforcement (IE).

Sucsequently, an additicoai tulletin was issued by IE wnich instructed holders of ocerating licenses for 3accccx &

Wilcox (3&W) designed reactors to take further actions, including immediate changes to decrease the reactor high pressure trip point and increase the pressuri:er power-ccerated relief valve (PORV) setting. '

'CIE Sulletins Nos. 79-05 (Acril 1,1979), 79-CEA (Acril 5,1979), and 79-058 (Acril 21,1979) acoiy to all E&W f acilities. ]

c.

n,

%i LJ.

/

7 908150

.-~

~ ~

The NRC staff identified certain other safety concerns that warranted addi-tional short-term design and procedural changes at operating facilities having S&W designed reactors.

Those were identified as items (a) tnrough (e) on page 1-7 of the " Office of Nuclear Reactor Regulation 5*atus Report to the Commission" dated April 25, 1979.

After a series of discussions between the NRC staff and the licensee concerning possible design nodifications and changes in ocerating procedures, the licensee agreed, i n letter 2 cated April 27, 1979 and May 4, 1979, to perform promotly certain actions.

The Commission found that operation of tne olant should not be resumed catil the actions described in Items (a) througn (g) of paragraph (1) of Saction IV of the Ceder are satisfactorily completed.

Our evaluation of the licensee's compliance with items (a) through (g) of paragraph (T) of Section IV of the Ceder is given below.

In performing this evaluation we have utili:ed additional information provided by the licensee in letters dated May 11, 18, 19, 22 (2), 23 (2), 25 (2), 29 and June 15 (2), 13, 21, 23 and 25, 1979 and numercus discussions with the licensee's staff Confirmation of design and procedural changes was nace by memcers of tne NRC staff _at the 08-1 site.

An audit of the training and performance of ne CB-1 reactor ocerators nas also performed by tre NRC staff to assure tnat the design and precedurai changes were understood and were being correctly imclemented 5y the operators.

f. :)'.U R., &; fi ut _, _

.w.

,m

=

4

3-EVALUATICN Item (a)

It was ordered that the licensee take the following action:

" Review all aspects of the safety grade auxiliary feedwater system to further upgrade components for added reliability and performance.

Present codifications will include the addition of dynamic braking on the auxiliary feedpumo turoine speed changer and provision of means for control room verification of the auxiliary feeewater flow to the staam generators.

This means of verification will be provided for one steam generator prior to startup from the present maintenance outage and for the other steam generator as soon as vendor-supplied equipment is available (estimated date is June 1, 1979).

In addition, the licensees will review and verify the adequacy of the auxiliary feedwater system cacacity.*

The auxiliary feccwater (AFW) systam at 08-1 consista of cwo safety grace AFW pucos capable of being actuated and contrailed by safety grade signals that ensure tne availability of feecwater to at least one steam generator, uncer the assumed conditions of a single failure.

In addition, the capability to manually actuate ard control AF4 is available in the control room.

The sourcas of water include two condensate storage tanks (C5T), the seriice natar system and the fire protection system.

The CSTs provide the normal succly (non-safety-grade) and the sereice water system is used as a backua safety grade suoply.

U d. i _ ' i

  • n.,

. A low level in either CST is alarmed to the operator and a continuous level is displayed inside the control room.

Low pressure switches on the AFW pump suction provide safety grace signals to automatically shift suction for the pump from the CSTs to the backup service water supply.

Additionally, the operator could also manually transfer the AFW suction to the fire water storage tank (FWST) in the fire protaction system.

Both steam-driven auxiliary feedwatar pump turbines at 08-1 are provided with a governor used for variable pump speed control.

The governor is equipped with a small DC motor which changes the speed setpoint on the turbine control valve, thereby controlling steam flow wnich regulates the turbine and pumo speed.

This DC motor receives " raise-and-lower" pulses from the safety grade steam generator level control system or the manual control switches (located in the control room), which change the turcine sceed as required.

Sulse length is automaticaliy increased the further steam generator level deviates frem its satpoint.

These changes in pump speed altar the AFW flow and thus control the natar level in the steam generators.

i A *2ynamic brake" feature has been added, which consists of a resistor and electrical contacts in parallel with the windings of the DC motor. When the control pulse is terminated, the braking resistor is placed in parallel with the motor windings, causing rapid dissipation of the energy associstad with the motor mcmentum (thus reducing the amount of motor coast).

This, in turn, reduces the amount of pump speed overshoot, therecy allowing fewer speed cnanges to match the AFW ficw rate to the steaming cata of the steam ;enerators.

udC :.c

  • e u..

5-The licensee has also added flow rate indication for both steam generator AFW inlet lines.

Each inlet line has a pipe-mounted ultrasonic flow transducer and signal conditioner.

These are 1ccated in the auxiliary building and are accessible during normal plant operations.

The signal conditioners provide outputs both locally and in the control room on the AFW pumo section of the nain control console.

Each device is designed to provida flow rate indication to each steam generator from 0 to 1000 gpm.

The systems are powered frem 120 VAC, 50 HZ buses wnich are fed by radundant non-Class IE station inverters.

Functional testing of the installed auxiliary feecwater flow rate indication is to be conducted in conjunction with the functional tasting of the dyrtmic braking modification of AFW pump turbine controls.

The staff concludes that the dynamic brake and AFW flow rate indication modifications are acceptable contingent upon successful testing prior to restart.

We have reviewed the piping and instrumentation diagrams and have determined that no active failure of a mechanical camconent, such as a pumo or valve, would preclude cotaining the required AFW flew rate.

The licensee has pre-vicusly performed tests of the manual and automatic level control system.

The test results showed that the control system func*ioned as designed to control steam generator level. Verification of acceptacle ficw cacacity for each of the t'no AFW pumps was based upon recorded steam generator level changes folicwing a previous reactor trip.

These data showed that each pump exceeded the design flew rate of 300 gpm at a steam generator pressure of 1050 psig.

(The 300 gpm is the flow rate delivered to tae steam generators and does not include tne acoroximately 250 gpm recirculation flow rata. )

.: v,-

<3 dk

%., '.)

m>-

-.e

. Additional information succitted by tne licensee (letter frem Lcwell E. Rce (TECO) to Mr. Robert W. Reid (NRC) dated May 23, 1979) shcws that a total minimum ficw, to one or both steam generators, of 550 gpm is required to supcort the accident analyses.

Based on these data and analyses, and the agreement by the licensee ta perform checxcut testing of the cynamic braking and ficw rate indication modifications prior to restart, ne conclude that adecuate assurance exists tnat the AFW system will deliver the required ficw rate ucen demand.

By letter (Lcwell E. Rce (TECC) to Mr. Racert W. Reid (NRC) dated _May 23, 1979), tne licensee provided results of a review of the cperating history of the AF4 system at CB-1.

The maximum number of failures cccurred during the initial ocerating and decugging pnase of the facility.

Fourteen (14) of the seventeen (17) reported failures occurred prior to January,1978.

Sucsequent to implementing system design changes as a result of several of these failures, the systems failure rate has been reduced and its reliaDility enhanced.

There have been 3 f ailures of AFW system cocconents frem January 1978 to cate.

(There were a total of 65 actuations of the AFW system in tais time pericc. )

Throe cifferent cccconents in tne AFW system were involved in tnese tnree failures:

(1) the speed centrol circuit for #1 AFW pume turcine, (2) a faulty limit switch on an AFW discharge valve, and (3) two sticky AFW puma turcine steam sucaly valves.

In each case, the licensee performed corrective actions andfailuresinthesecccccnentsha'[enotrecccurred.

The staff concluces, tnat the licensee has increasec tne reliacility of tne AFW systam by imole-menting accrecriata corrective actions and design tecifications.

tl L} tA.'.. ' 5.*.

.lf'

. P


w we

+ - *

. - - In addition, the licensee has revised the administrative procedure pertaining to valve alignment and control.

These revisions te A0 1839.02 (" Operation and Control of Locked Valves ) provide further assurance that mispositioning of d

AFW system valves would be detected.

Based on the above evaluation, the NRC staff concludes that the licensee has complied with the recuirement of Item (a) of the Order.

Item (b)

It was also ordered that the licensee:

" Revise operating procedures as necessary to eliminate the option of using the Integrated Control System as a backuo means for controlling auxiliary feedwater flow. "

As indicated in Item (a), One CB-1 AFW system has seen designed as a safety grace systam and, as such, is separate from the integrated control system (ICS); newever, the licensee has indicatad tnat tne AFW system is cacaole of being swi ched to the ICS mcde for a bacxup teans of control. As currently designed, t.9e AFW system has three coerational nodes of controlling flow:

ICS control", auto essential" and

  • manual.
  • We recuested that the licensee consider a more pcsitive means to assure the continued separacility of the ICS control position of the mede selector switches. The licensee agreed (letter f rom Lowell E. Ree (TECO) to Mr. Rcbert W. Reid (NRC) dated 'une 15,1979) to

'd N E.? ' G '

.-w.

. install a mechanical s+cp on these switches to further deter use of the ICS

contro,

,c...

sir.

The Ii site inspector has verified the installation of this mechanical stop.

The licensee has revised SP 1106.06 (" Auxiliary Feedwater System'), which describes procedures for AFW system operation.

This procedure specifically prohibits the use of the ICS control position on the mode selector switches.

Procedural steps for placing the AFW system in service for plant startup require the operator to place the AFW mode selector switches in the auto-essential position. We have reviewed the revised precedure for AFW switch operation and conclude there is sufficient guidance to prevent use of the AFW system in the ICS mode of control.

Other plant procedures that made reference to the ICS control mode of AFW have been revised by the licensee to no longer authorize that moce of control. The staff has reviewed those procedures and concludes that those revisions are acequata.

In addition, the NRC staff audit confirmed that the control roca operators are aware that ICS control of AFV is prohibitad.

Based on the above evaluation, we concluce that tne licensee has comolied with the requirements of Item (b) of the Order.

Item (c)

The Groer requires that the if censee:

'hiJb5.'iE>

.g.

"!mpleme t a hard wired control grade reactor trip that aculd be actuated on loss of main feedwater and/or turbine trip."

fhe C8-1 original design did not have a direct reactor trip frem a malfunction in the secondary system (loss of main feedwatar and/or turbine trip).

To obta'in an earlier reactor trip (rather than delaying the trip until an operator took action or until a primary system parameter exceeded its trip setcoint),

the licensee committed to install a hard-wired, centrol grade reactor trip on tne loss of all sain feedwater and/or on urbine t-ip (letter frem Lowell E. Roe (TECO) to H. Centon (NRC) dated April 27, 1979).

ITe purpose of this antici-patory trip is to minimize the potential for opening c' the pcwer-eperated relief valve (PORV) and/or tne safety valves on the pressuri:er.

This new circuitry meets this objective by providing a reactor trip during the incipient stage of the related transients (turbine trip and/or loss of main feedwater).

TECD has added control grade circuitry to 08-1 which is designed to provide an automatic reactor trip when either tne main turoine trips or tnere is a reverse differential pressure of 177 psid across both of the two nain feecwatar cneck valves (cne check valve is located in the main feecwatar discnarge piping associated witn each steam generator).

The main tureine trip is sensed by a normally deenergized auxiliary relay associated with the main turoine generator master trip bus.

The pewer for this tus is provided from a 21 voit :C scurce, which in turn is provided pcwer (througn rectifier circuitry) f Om a non-Class IE inverter supolied 120 voit AC distribution panel.

A contact frem the above

.:1

\\$ Lli!. ( * [,

_ auxiliary relay is arranged into a 120 volt AC circuit containing four normally deenergized relays.

Power for this 120 volt circuit is provided from a Class lE invertar supplied distribution panel.

The design for these four relays and appropriate associated circuitry conform to Class lE requirements, including physical independence and provisions for testing.

Each of these four relays provide one contact wnich is arranged in seriec with one of the four Class IE undervoltage coils -associated with one of the four AC reactor trip circuit breakers (one undervoltage coil associated with each AC reactor trip circuit breaker). When these relays are energized, power to the associatad Class IE undervoltage coils is interrupted so as to produce the desired reactor trip.

As indicated above, differential pressure switches across check valves, located in the main feedwater pump discharge piping, actuate upon sensing a reverse dif ferential pressure across these check valves.

Two contacts from these differential pressure switches are arranged into a 125 volt DC circuit, which is provided power frcm a Class IE 125 volt distribution panel.

This circuit contains two associated CC relays.

Two contacts (one contact per relay) associated with these relays are arranged in series.

This series contact arrangement is provided in parallel witn the contact associated witn the cain turbine generator mastar trip bus.

The remaining circuitry associated with this trip is identical and common (shared) to that described acove for the turoine trip (including pcwer supply identification).

Provisions have been included in the design to manually bypass and to reinstata the reactor trip feature asscciatad w'th the main turoine generator trip.

To UbE['Ik

. supplement this feature, the design includes an annunciator which actuatas whenever this reactor trip is bypassed and t's reactor power level is above 15 percent.

Access to this bypass switch will require a key which is under suitable adninistrative control. Cperator verification of the bypass removal is required by procedure during power escalation.

The NRC staf f has-reviewed these procedures and concludes that sufficient administrative control exists.

No bypass features are included in the design for the reactor trio feature associated with the loss of main feedwater circuitry.

During normal startup or shutdcwn, an electric auxiliary pump is used when the staam driven main feedwater pumps are not available.

The licensee has analy:ed this additional circuitry with respect to its independence from the existing reactor trip system and to assure that the design and operation of this additional circuitry will neither degrade the reliability of the existing reactor protection system nor create any new adverse safety system interactions.

Based on our review of the implementation of the added trip circuitry, with rescect to its incependence from the existing trip circuitry, we conclude that this additien will not cegrace the existing reactor protection system design.

In addition, the licensee nas satisf actorily completed testing of this trip circuitry.

The licensee has committad to perform a monthly ceriodic test of the acded circuitry to demcnstrate its ability to ocen the AC reactor trip circuit breakers (tripping of the AC reactor trip circuit breakers via the uncer-voltage trip circuit). We conclude that thers is reasonable assurance that the additional circuitry will perform its intanced function.

rg h,

fl, e---'E'

12 -

Based on the above evaluation, we conclude that the licensee has comolied with the requirements of Item (c) of the Orcer.

Item (a)

This Item in the Order requi es the licensee to:

"Ccmplete analyses for potential small breaks anc cevelen anc imclement operating instructions to define coerator action."

By letter, (Lowell E. Roe (TECO) to H. Denton (NRC) dated April 27, 1979), tne licensee agreed to provice the analyses and operating procecures of this requirement.

B&W, tne reactor vendor for the 08-1 plant, submitted generic analyses for B&W plants entitled, " Evaluation of Trarisient Senavior and Small Reactor Coolant Systems Breaks in tne 177 Fuel Assemoly Plant," and succlements to taese analyses (References 1 througn 5).

Accitional information specific to 08-1 was transmittaa in References 5 to 3.

The transmittal uncer Reference 5 contains Volume III for the B&W generic stucy covering raisec-icco plants.

Reference 7 provices additional analytical results specific to 08-1 nita acor:priata auxiliary faecwatar flow ratas.

Reference 3 previces accitional analytical results for the loss of all main faecwater flow accicent with loss of all AF4. This lattar analysis demenstratas tnat c..cability exists at CS-1.nicn the ocerator could use in the unlikely evelt of a loss of i.. 1.>7.

.:ory s>>--.

n.,__

omme

~-s-

. main feecwater and a loss of both safety grace AFW trains.

Inis cacacility consists of using the combined functions the makeuc pumps,' the electric startup auxiliary feedwater pumo and the PCRV to achieve depressuri:ation (only if necessary). We requested that the availacility of this option te incorporated in procedures at 08-1.

The NRC staff will review nese procecural cnanges prior to startup.

By letter, (Lcwell E. Roe (TEC3) to Mr. Racer W. Reic (NRC) cated ay 22, 1379), TEC3 referencac tne analyses as accrocriata for 08-1.

The staff evaluation of the S&W generic study has been completed and tne -esuits of :ne evaluation ill be issued os a NUREG recort in July 1979.

A principal finding of our review of tne 08-1 submittals and the generic study is a reconfirmation that loss-of-coolant accident (LCCA) analyses of breaks at tne lower end of 7

the small breaks spectrum (smaller than 0.04 ft.') demonstrate that a combination of heat removal by the steam generators, high pressure injection (HPI) system and through the break ensure adequate core cooling.

The AFW system used to remove heat through the steam generators nas oeen mccifiec to ennance its reliacility as ciscussac in Itam (a).

Uncovering of tne reactor core is not precictac for breaks at this and of tne small break spectrum witn these features available, therefore, cladcing temceratures do not rise significantly acove pre-reactor tric temceratures (less nan SCO*F), and remain.eli within the 10 CFR 50.46 limit of 2000 F.

The acility to remove neat via tne steam generators has always been recogni:ed to ce an imcortant consideration anen analyting very s,T..I breaks.

The

'At C6-1, tne makeup pumcs are separate from the HP! ;umes.

e x-s

?y $)O $AA'

. licensee demonstrated that permanent less of main feedwater and loss of AFW for the first 20 minutes of a small LCCA will not result in uncovering the reactor core. hcwever, when AFW is delayed beyond tnis time, a positive reliance en AFW actuation exists as a result of the relatively low (1600 psig)

HPI system snutoff head for CE-1.

Thus ermanent loss of botn main and auxiliary feecwater could result in uncovering the core and fuel damage for the facility cecause of tne unavailability of the hign pressure injection pumps.

Maxeup pump and startuo feecwater pumo actuation, a3 discussed in the analysis of Reference 3 fo.' the loss of feedwater accicent witn cermanent loss of AF4, are considered potentially capable of maintaining the vessel mixture acove the core for a small break, tot this scenario was nct confirmed in the smail break analyses.

The licensee's position is that such analyses are unwarranted in light of the safety-grace design of the AFW system.

Since the additional neat removal and coolant makeup cacaoility does exist at 08-1, ne requested that the procecures identify the availability of this cotion.

Imolementation of this procecural cnange will te verifiet_ by the staff prior to restart.

While the staff rec qni:es tnat the AFW system is safety grace, e also note inat tne licensee nas agreed to continue to review performance of the AFW system for assurance of reliacility anc performance.

Consistent witn tnis long-term agreement,.e will require tnat the licensee modi fy the plant to provice the greater degree of diversity offered by a 10C% cacacity motor-oceratad AFW cumo, or an alternative acceptable to the staff Another asnect of the analytical studies concucted.as an assessment of the effect of recent design enanges n the lift frecuency of Oressuri:er safety a J u.;. o'r)

. y ut e

and relief valves.

ihe c' sign changes included:

(1) a change in the setacint of the PORV from 2255 psig to 2400 psig, (2) a cnange in the hign pressure reactor trip set;oint from 2353 psig to 2300 psig, and (3) the installation of anticipatory reactor trips on turbine trip a'd/or loss of main feedwater.

In the past, during turoine trip and loss of feecwater transients, the PORV was l i f tac. With the new design, thesa transients do not result in lifting of this valve.

However, lifting of both PORV and safety valves mignt occ'er in the cases of rod withdrawal or inadvertant 5cron dilution transients, using the normally conservative assumptions presented in Chapter 15 of tne Final Safety Analysis Report (F5AR). The above design changes did not affect the lif t frequency of the valves for these Chapter 15 safety analyses.

Based on our review of the analyses presentec Oy S&W, tne staff has cetarmined that a loss of all main feecwater with (1) an isolated ?CRV (closed block valve), b : safety valves opening and closing as designed, or (2) a stucx ocen PCRV consequentially does not result in uncovering the reactor core, provided AFW oumos are initiated within 20 minutes.

It ir also conc;udeo, Onat in the event of a loss of all AFW for either casa, covering of the core would ce sustained to lorg-: arm cooling by ocerator actions cescribec in the analysis of Reference 3.

These actions consist of starting at least one of the two takaua pumps, starting the startuo feedwater pum:, and ocening the FORY (Only if needed).

5dsad on the Consecuences calculated for SmaIl break LCCAs and loss of all main feecwater events, and taking into account the ax ectad reliacility of the AFW anc HP: systems for 08-I, we conclade that the licensee has conclied with the analyses portion of Item (d) of the Order.

. #1-o

(;i)Jf.li3*J

-+

To support ing-term operation of the facility, requirements will be developed for additional and more detailed analyses of loss of feedwater and other ariticipated transients.

More detailed analyses of small break LOCA events are also needed for this purpose. Accordingly, the licensee will be required to provide the analyses discussed in Sections 3.4.1 and S.4.2 of the recent NRC

" Staff Report of the Generic.sessment of Feedwater Transients in Pressuri:ed Water Reactors Designed by the Sabcock and Wilcox Comcany" ('lUREG C560).

Further details on these analyses and their applicability to other P'4Rs and SWRs will be specified by the staff in the near fut:Jre.

In addition, to assist the staff in developing more detailed guidanca on design requirements of relief and safety valve reliability during anticipatec transients, as discussed in Section S.4.6 7f NUREG 0560, tne licensee will be required to provide analyses of the lift frequency and the mechanical reliacility of :ne pressurizer relief and safety valves of the CB-1 f acility.

The S&W analyses show that scoe operator actions, both immediata and followup, are recuired under certain circumstances for a smali creak accicent.

mmediata ocerator actions are defined as tnose actions, committad to memory by the ocerators, wnich tust Oe carried out as scen as the proolem is diagnosed.

Follcwup acti ns require ocerators to consult and follow stecs in neittaq and approved procedures. These procedures must always be readily available in the control recm for the ocerators' use.

Guidelines. era developed by 3&W to assist tne ocerating S&W facilities to deveico emergency procacures for the small break accident.

. y, -

,c

.C n) ?.-.L)*

. The " Operating Guidelines for Small Breaks" were issued by B&W cn May 5,1979 and reviewed by the NRC staff.

Revisions rec:mmended by the staff ere in-corporated in tne quicelines.* In addition, by letter, the licensee sucmitted succlemental guicelines (Lowell E. Rce (TECO) to Mr. Recert W.

Reid (NRC) cated May 22, 1979).

In response to.these guicelines, the licensee mace substantial revisiens to EP 1202.06 ("Less of Reactor C clant anc Reactor Coolant Pressure"), E? 1202.14 ("Less of Reacter C:clant ricw/RCP ' rip"), anc EP 1202.26 (" Lass of 5 team' Generater Feed").

7hese emergency prececures define the required operator action in response to a scectrum of ac:icents including a LCCA in coni nction eith varicus equicment availacility and u

failures.

The crocecure cealing with loss of reactor :colant (EP 1202.06) is diviced into tnree sections.

7he first section cea.s witn small reactor c olant system leaks within the capacity of the makeup pumes and assumes the reactor dces not autcmatically tcip.

The seconc section assumes a small brea< itnin

he cacacity of tne HPI system and a situaticn wnere tne SFAS"" and reacter trics may or may not automatically Occur.

This section incorporates tne 3&W smail break guicance and provices for cperator actions in the event otner

"[Let:ar trem J. Taylor (B&W) to Z. Rosttac:y (NRC) dated May 16. 1979]

    • [The safety features actuation system (SFAS) monitors var anles to detect loss i

of reactor c001 ant system boundary integrity.

Ucon ce.ection of 'Out-of-limit" canditions of nese variacles, tne system initiates varicu: actions, decending ucco the iccation and severity of tne 'Out-of-limit" : enc 1 fons measurec.

These actions can include:

initiation of emergency core c cling (ECC), nica c:nsists of hign pressure injection (HPI) anc Icw pressure, af ection ('_?!);

containment vessel cooling and isolation; containment lessei spray systaas; and starting of the amergency diesel geneaators.]

(;iSS ~ b E systems (such as reactor coolant pumps) do not operata as extected.

The third section of this precedure deals with a pipe rupture well in excess of the capability of the makeup and/or HPI pumps (a large break,in wnich the system depressurizes tn the point of low pressure infection). Autcmatic reactor trip and SFAS actuation are assumed.

In all cases dealing with a small break, tne operator actions are aimed at achieving a safe cold shutdcwn in accordance with the normai C00ldown procedure.

As indicated above, precedures provide guidance to the cperators for cealing with small breaks in the event of a degraded condition (sach as loss of reactor coolant pumps).

If the reactor c0clant pumps are inoperable, the Operat0r is directed to establish and verify natural circulation.

Procedural steps to restore reactor coolant pumo operation, once a pump becomes available, are creviced.

In the event natural circulation cannot be establisned and a reactor coolant pump cannot be restarted and plant pressure reaches 2300 psig, the cperator is provided procedural steps to relieve tne heat energy via the PCRV.

(Additional relief capacity is proviced via the code safety valves if the PCRV is inocerable).

In the event that normal feedwater is lost to the steam generators, auxiliary feedwater is autcmatically initiated via the safety grade AFW system.

EP 1202.25 provides Operator guidance in this event. With SFAS actuation, steam generator level is autcmatically maintained at 96 incnes on the startuo range to assure adequata neat remeval during the small break event.

n h%.

k+

%b

. For all cases in which HPI is manually or automatically initiated, the operators are speci fically instructed to maintain maximum HPI flew unless one of the two following criteria is met:

(1) L0w pressure injection has been cperating for greatar than 20 ninutas with flew rates in excess of 1000 gallons er minute per train, or (2) All hot and cold leg tamceratures are at least 50 degrees teicw the saturation temperature for the existing reactor coolant system pressure.

If tne 50 degrees succooling cannot be maintained aftar high pressure injection cutof f, the high pressure injection shall be reactuated.

This requirement to determine and maintain 50*F succccling has been incorporated into EP 1202.06 (" Loss of Reactor Ccolant and Reactor Ccolant Pressure") and E? 1202.24 (" Steam Supply System Rupture").

The procecures also provide instructions to the operators to eneck alternata instrumentation chancels to confirm r.ey parameter readings, such as the degree of succooling.

Accordingly, One use of core exit thermccouples as alternate tamcerature indicators is addressed in the procedures.

Under degraded c0 cling c.;diti:ns (sucn as a LOCA), tne cressure-temperature limits cor.sidered in the Technical Specifica*

tions are not acolicable to the ensuing cepressurization and c0cidewn because these limits were developed for normal and ucset ocerating c:ccitions only.

Censity differencas between the ccwncemer and reaccor core will cause recirculacion ficw between the C0re axit and downcemer via tne venc valves.

L 4

. Mixing of the hot core exit water with the cold HPI water (or makeup water) will provide sufficiently warm vessel temperatures to preclude any significant thermal shock effects to the vessel.

Subsequent restoration of AFW would depressurize ~he reactor coolant system to belcw 600 psig where pressure vessel integrity is assured for any reasonable thermal transients that mignt subsequently occur.

S&W has agreed to provide a detailed thermal-mcchanical generic report on the tenavio. of vessel materials for those extreme conditions.

The "Less of Reactor Coolant and Reactor Ccclant Pressure" procedure was reviewed by the NRC staff to determine its conformance with the S&W guidelines.

Comments generated as a result of this review were incorporated in a further revision to the procedure. A member of the NRC staff walked through this emergency procedure in the Davis-Sesse centrol recm.

The procedure was judged to provide adequate guidance to the operators to cope with a small break LCCA.

The instrumentation necessary to diagnose the break, the indications and controls required by the action statements, and the administrative controis wnicn prevent unacceptacle limits frem being exceeced are readily avaliaole to the ccerators. We conclude that the operators shculd be acle to use tnis procedure to bring the plant to a safe shutdcwn condition in the event of a small break accident.

An audit of 9 of the 25 if censed reactor ocerators and senice reactor operators was conducted by the NRC staff to determine tne operators' understanding of the small break accident, including hcw they are required to diagncse and respond to it.

The 08-1 staff has conducted special training sessions for the

~. O ~

'r) uo-r; J cperators on tne concept of and use of Emergency Precedure 1202.06.

The operators were found to have sufficient knowledge Of the small break pheno-mencn and the general requirements of the emergency procedure, although some deficiences were identified which were primarily due to tne coerators' lack of familiarity with the recently revised procedure.

All ccerators will receive additional training on E? 1202.06 and a facility acministered audit Orior to assuming licensec duties during pcwer aceraticn.

The audit of the caerators also included cuestioning accut tne TMI-2 accident and tne resulting design cnanges mace at 08-1.

The discussions covered the initiating events of the incident, the respense of tne plant to tne simul-taneous loss of feedwater and small break LOCA (PCRV stuck ccen), and operator actions tna: nere taken during the course of the incident.

n addition, similarities and differences between the TMI-2 accicent and the 06-1 incident of Septemcer 24, 1977 were discussed. We found tneir level of understanding sufficient to be acle to respond to a similar situation if it happened at 08-1.

We also conclude that they have acequate '<newledge of succ: cling and saturatec concitions and are acle to recogni:e eacn concition in :ne primary c clant system oy several tetaccs.

The AFW system nas also discussed curing the audit to determine the ccerators' acility to assure precer starting and operation of the system during normal conditions, as well as curing acverse conditions sucn as loss of offsita pcwer :r loss of main feecwater.

The long-term Oceration of tne systam nas examined to evaluate the cceratcrs' ability to use availacle tacual controls anc water succlies.

The level of understancing was found to be sufficient to assure crecer sacet-and long-term AFW ficw to the steam generators.

,,...,3 u (J,

tj

.w

<- = -.+

. The licensed reactor Operators and senior reactor operators have received training concerning the THI-2 accident, small break LOCA recognition, design modifications, and precedure changes.

The training included formali:ed class-rocm sessions and on-shift review of training material and emergency prececure cnanges.

To determir.e the effectiveness of this training program, a rf tten exam nas acninistrated to all licensed personnel ty the licensee. The exam nas reviewed and fwund acceatacle cy a memcer of the NRC staff Incividuais scoring liess than 90 cercent on the exam will receive accitional training and aill not assume licensed cuties until a score of at least 90 percent is attained on an equivalent, but differ =rt exam.

The NRC staff conductec audits to evaluate tne effectiveness of tne training program; The results were judged satisf actory with scme deficiencies noted to the CB-1 staf'.

The 09-1 staff will use the results of these sudits as well as any generic weaknesses discovered on the aritten exams in their development of future training and requalification programs. The NRC staff will review all results and records as part of the normal inscection function of the C8-1 requalification pecgram.

We conclude that there is acequata assurance that the operators at 08-1 nave, and will continue to receive, a sufficient level of training concerning the TMI-2 accicent.

Based en the above evaluation, we conclude that the licensee has c cclied with the requirements of Item (d) of the Order.

< > ~ ' rs

,ti a).' '... b,

23 -

Item (e)

The Order requires that:

" All licensed reactor operators and senior reactor ccerators will have comoleted the Three Mile Island Unit No. 2 simulater training at CIW."

T'e licensee nas c:nfirmed that all reactor ccerators and senior reactor Oce-ators have ccmcletad the TMI-2 simulator training at S&W as required :y the Orcer.

This training consisted of a class discussion of tne E4!-2 event and a cemenstration of tne event on ne simulator and new it snculd have teen controllec. The class discussion was accut one hour long and the remainder of the four hour session was conducted on tne simulator.

The TMI-2 event, inclucing operational errors, was demonstrated to each ccerator.

The event was again initiated and tne operators were given "hancs-en" ex;erience in successfully regaining control of the piant cy several metteds. Other transienta, wnica resulted in cecressuri:ation and saturatien conditions, =ere presented to the ccerators, in.nica they maneuvered tne plant to a stacie, succocied condition.

The licensee has sutmittad cepf es of precedures tnat were revised as a result of this Order and actions the licensee has taken to preclude the occurrence of an incicent similar to inat.nica cccurred at TMI-2."

The crecacures reviewed ty One staff include:

'[As notec on cage 16 cf this Safety Evaluation, acditional anc more cetailec analyses of icss-of-feecwater transients and atner anticipa ec transients will te dcne, wnica coulc affect Onese prececures in the.cng-tarm. ]

~

v o,

N t.

,e-

  • -e..

we-.

. E? 1202.01 Lead Rejection E? 1202.02 Station Blackout E? 1202.03 RCS Overpressure Anticipatory. Manual Trip E? 1202.04 Reactor-Turcine Trip E? 1202.06 Loss of Reac:ce Ccolant and Reactor Ccciant Pressure EP 1202.14 Loss of RC Flow /RCP Tets E? 1202.22 Hign Concenser Pressure E? 1202.24 Steam Sucaly Systa.m Ruoture E? 1202.25 Loss of Staa.m Generator Feed A8 1203.04 Depressurization of the RCS with Safety Grade E uipment AB 1203.02 Loss of All AC Pcwer AP 2003.41.14 Hign Pressure Injection Hign Flcw Alarm AP 3003.29.50 Lcw Pressure Injection Hign Flcw Alarm AP 3003.51.54 Hign Pressure Injection Low Flow Alarm AP 3C03.59.50 Lew Prnssure Injection Low Flow Alarm SP 1105.16 Staam anc Feecwater Ruoture Control System Operating Precacure SP 11C6.06 Auxiliary Feecwater System IT 5071.01 Auxiliary Feecwater Systam Mentaly Test Special Order No. 20 Additional Guidance for Checking Critical Parameters for Emergency Procacures The licensee's revised procecures provide acditional guidance for tne acerators wnen coping with emergency pl. int conditions. Where aperceriata, operators are s, o; f es uuu.- u,

. directed to recheck certain critical plant parameters.

Operators are also directed to check alternate instrument channels to confirm readings and recuce the cossibility of reliance on f aulty or misleading indications.

NRC staff comments on the licensee's procedures nave been incorocrateo into the revised documents.

These revisions have been reviewed by the staff and determined to be acceotacle.

The staff walked tnrcugh tne following procedures with the control room operators:

E? 1202.06 (" Loss of Reactor Coolant and Reactor Coolant Pressure"), E? 1202.14 (" Loss of RC Flow / RCP Trip"), E? 1202.25

(" Loss of Steam Generator Feed"), and $P 1106.06 (" Auxiliary Feecwater System ').

Based on this walk through and interviews with the operators, (see the discussion of the NRC staff audit of operators under Item (d)), we conclude that the procedures are functionally adequate and the operator training on tneir use is sati s f actory.

Based on the above evaluation, we concluce that the licensee is in comoliance

.ita Item (e) of tne Order.

item (f)

The Order requires that the licensee:

Sucmit a reevaluation of the TECO analysis of One need for automatic or acministrative control of steam generator level setcoints during auxillary feecwater system operation, oreviously submitted by TECO letter of Cecemcer 22, 1978, in 11gnt of the Three Mile Islanc No. 2 incident."

.o td b),s', 'J

-=

. By lettar, (Lowell E. Rce (TEf.0) to Mr. Recert W. Reid (NRC) dated May 19, 1979), the licensee provided additional discussion of the steam generator dual level setpoint. The need for this feature is to reduce the potential for loss of pressurf:er level indication as a result of overcooling of the primary system for non-LOCA events.

The results of a natural circulation test concuctec at CB-1 and B&W analyses cemenstrate tnat CB-1 can *:e cceratad at a low staam generator level (35 incnes on the startuo range instrumentatien).

The nigh level setpoint (96 inches indicated on the startup rarge instrumentation) is required since previous small break analyses assumec that auxiliary feecwater was controlled to a steam generator level of 96 inches.

Pending incor oration of permanent design modifications to provide the automatic dual setooint steam generator level control, emergency precedures instruct the cperator to manually control the steam generator level at 35 inches for all events requiring AFW unless an SFAS level 2" signal occurs. When the SFAS level 2 signal occurs, the operator is instructed to control the steam generator level at 96 inches by placing the AFW mode selector switch in the auto essential position.

This manual provision required no previous change to the cesign of :ne AFW control system. The future circuitry modification, to automatically control to 35 incnes, will e reviewed by the staff during tne long term.

TECO has cited Reference 9 to demonstrne tnat no unreviewed safety issues or detrimental accident consequences *culd result if tne opernor failed to manually contro!

the staam generator level at 35 inches.

The staff reviewed the information c:ntained in this reference and c:ncluded that accitional information was recuired to verify that the effects of manually c:ntrailing the steam generator level at 35 inches is adecuate for the CB-1 F5AR Chactar 15 transient and T5FA5 levei 2 - An SFAS level 2 signal is develcoad wnen reactor c olant system pressure creos to 1600 psig or containment vessel pressure increases to 4 psig.]

U m.' ;- ; -

..: r y

+, - -

J 27 -

accicent analyses, and the more recent 3&W small creak analyses (Reference 1).

By letter, (Lowell E. Rce (TECO) to Mr. Rccert W.

Reid (NRC) dated June 15, 1979), the licensee stated that the control of the steam generator level at 35 incnes has no adverse effect on the 08-1 FSAR analyses, since tne peak reactor temoerature and pressure folicwing the most severe transients (loss of feecwater, feecwater line breaks, loss of offsite power) Occur crice to initiation of the A F4.

The results of natural circulatien testing conductec at 08-1 sue:crt tne ef fectiveness of the 35 inen steam generator control level to maintain natural circulation and remcve cecay heat for:

(1) transients that result in loss of forced cir culation (loss of offsite power) and (2) for small breaxs (less nan 0.01 ft.") tnat depressurize slow enougn that it is possicle to manually centrol the steam generator level prior to actuation of the SFAS level 2 signal.

For small breaks larger than 0.01 f t.2 recuction of the reactor coolant system pressure to SFAS level 2 cccurs prior to the steam generator level decreasing to 96 inches. With the steam generator level controlled at 35 inches, the effectiveness of natural circulation is sucn that there is no small break si::e that will result in repressuri:ation of the primary system

.itncut an SFAS level 2 actuation.

The staff has reviewed tne information crovided :y TECO in tne referenced cecaments anc c:ncluces tnat dual levei set:oints, with manual control of tne steam generator level at 35 incnes, are acceptacle. Also, tne NRC staff has serified that this manual control

acacility has :een previcusly demonstritec.

The licensee has sucmitted revised procacures, wnien the staff nas reviewed, tnat provide requirements for staam generator level control.

These procedures

.a e

==e---

+-w e

28 -

include:

E? 1202.06 (" Loss of Reactor Ccolant and Reactor Ccolant Pressure"),

EP 1202.14 (" Loss of RC Flow /RCP Trip") and E? 1202.25 ("Less of Steam Generator Feed").

The NRC staff has verified that these procedures instruct the operator to confirm that the AFW mcde selector switches are in tha auto-essential position and maintaining steam generator level at 96 inches en the startuo range indication in the event SFAS level 2 c0ndition is present.

If a SFAS level 2 condition is.not present and an AFW system demand ever.*,

cccurs, steam generator levcis will autcmatically control at 96 inches (since the AFW mode selector switches are in the auto-essential pcsition).

The operator is directed to take manual cor. trol of steam generator level and maintain level at 35 inenes en th.e startup range incication.

If an SFAS Level 2 condition Lubsequently deveicos, the coerator must return the AFW mode selector switches to the auto essential position to alicw automatic level control at 96 inches.

Therefore, the emergency procedures are written to permit manual control of steam generator level af ter an automatic initiation of AFW cnly if an SFAS level 2 condition is not present.

If a SFAS level 2 concition is present (or develces), the ccerator is cirected to leave (or return) the AFW mcde selector switenes in the auto-essential position.

In addition, a warning plate has been installed adjacent to the acce selector switch for each AFW train, remincing the ccerator of the recuirement to maintain the switch in the auto-estantial position mcde if an SFA'i level 2 condition is present.

The NRC staff nas verified the installation of this warning plate.

Also, during the audit the NRC staff conf f-med that J..'. '-

.e-.

--we.,e+

Ww,-

-%,-.---w

.w%

. the control rocm ooerstors are aware of the requirements outlined in the revised procedures and understand the purpose of the warning plate.

Based on the above evaluation, we conclude that the licensee has complied with the requirements of Item (f) of the Order.

Item (c)

The Order requires that the ifcensee:

"Sucmit a review of the previous TECO evaluation of the Septemcer 24, 1977 event involving equipment preelems and depressuri:stion of the primary system at Davis-Besse 1 in light of the Three Mile Island Unit No. 2 incident."

By lettar (Lowell E. Rce (TECO) to Mr. Rcbert 'd.

Reid (NRC) dated May 18, 1979), the licensee sutmitted additional discussion of the Sectember Za,1977 event.

This event was similar in several important areas to the TMI-2 accident.

The initiating malfunction was a icss of.nain feecwater (the same as TMI-2);

hcwever, the ensuing trainsient was much less severe than TMI-2 for several significart reascns.

The foi!cwing discussion comcares The 08-1 event to the accident at TMI-2.

The bases for this coccarison are the six human, design and techanical failures described in IE Bulletin 79-05A (April 3,1979) anicn resultad in core damage and radiation releases at the TMI-2 nuclear plant.

b h) E.._.J :

~-

, 1.

At the time of the initiating event, loss of feedwater. (it TMI-2) both of the auxiliary feedwater trains were valved out of service.

The 08-1 loss of feedwater (LOFW', event initiated both trains of AFW.

However, oniy one train fed i:s associated steam generator (SG) due to a mal functie' of a turbine governor wnich kept one of tne two AFW curp turcines at a sceed insuf ficient to pumo water into its 9:ioci ated SG.

As a M, ult of the 08-1 event, the modifications that nave been made include:

(1) the AFW pump turbine governors were modified to prevent

~

binding malfunctions; (2) springs were installed in the AFW governor to prevent closure of the governor valve due to vibration; (3) the AF4 governor control circuitry relays were replaced (see additional AFW discussions in Item (a)).

2.

The cressuri:er cower-ocerated relief valve (PCRV), which ocened during tne initial cressure surge (at TMI-2), failed to close when cressurt decreased cet ow tne 1ctuation level.

During the 08 ' LCFW, the PCRV also failod to close, causing loss of coolant and s:ce voiding in the reactor coolant system (RC3).

However, the acerators recognized the ocen ?CRV about 20 sinutes into the event (coccared with 21/2 hours at TMI-2) and resconced by closing the PCRV block vaive and reinitiating high pressus e infection (HP!) flow.

c$

L LJs

31 -

The 08-1 unit has been modified to provide the operator with a better status of the position of the PORV.

The emergency precedures were also revised and new require the operator to verify that no leak exists at the top of the pressurizer by monitoring the saturatien curve and quench tank pressure and level.

3.

Followino racid decressurization of the cressuri:er (at IMI-2), the cressuri:er level indication may have led to erroneous inferences of hign level in the RCS.

This erronecus hich level indication accarentiv led the ccerators to crematurely terminate HPI. even throuch voids existad in the RCS.

For the 08-1 LOFW event, the operator also initially terminated HPI cue

  • o a hign pressurizer 'evei indi:ation; hcwever, the c;erator recognized the open PORV at 20 minutes and reinitiated HPI at 49 minutes (after failing to control pressurizer level with a second makeuo pump).

03-1 procedurec have oeen revised and new require that for all cases in wnich HP1 is initiated, maximum HPI ficw i? to be maintained unless one of two criteria is set.

These criteria are addressed in Item (d).

4.

Because the containment jgf;

,; i. slate en 'P! ini tiation ( at TMI-2). the hichiv radicactive w;*

- t e relief valve di scharce was cumced out of containment bv the auton

~ an of a transfer cumo.

This watea entered the radicactive was*e tree,tnent system in the auxili ary building O~

' cr L Lf-

.e+

.ei

. where son.e of it overflowed to the floor.

Outcassinc from this water and discharce throuch the auxiliary buildina ventilation system and 'ilters was the crincioal source of the offsite release of radioactive nob 7e cases.

Containment isolation at 08-1 occurs at either 1600 psig RCS pressure (HPI initiation-) or 4 psig containment vessel pressure.

Curing the CB-l event, containment isolation signals occurrsd and the sumo was not pumced outside containment as at TMI-2.

5.

Suosecuentiv. the Ho! system was intermittantiv ccerated (at TMI-2'.

attemotine to control RCS inventory losses throuch the PCRV, accarent_z based on cressurizer level indication.

Due to the cresence Of steam and/or noncondensibie voids elsewhere in the RCS, this led to a further reduction in crimarv coolant inventarv.

Curing the CB-1 event, the coerator initially tried to control the pressur-1:er level decrease with a second make up pumo aftar closing the PCRV block valve.

Mcwever, aftar tne pressuri:ar level decreased furtner he restartad a HPI pump. when ne pressurizer level was recovered, he terminated the HPI ficw.

At this time piant parametars,ere under control and the plant was brought to a stabili:ed conditicn.

As indicatad in Part 3 above, C8-1 procedures have been revised to require tnat for all cases in which HPI is initiatac, maximum HPI flow is to :e raintained unless one of two critaria is met.

These critaria are accressed in Itam (d).

_ <> ~.n N O A..

.l l '

+,e--

.--w---

.~ -

a

--+-

. 6.

Tricoing of reactor coolant cumos durinc the course of the transient (at TMI-2), to crotect acainst cumo damace due to como vibration, led to fuel damage since voids in the RCS crevented natural circulation.

During the CB-1 incident, two RCP's were tripped to recuce system heat input into the RCS.

One RCP per loop was maintained in operation througnout the incident.

The 08-1 emergency operating peccedures now require keeping at. least one RCP per loco running in the event of a smali LOCA.

To summari:e Item (g) of the Order, the staff views the Septamcer 24, 1977 event at CS-1 to have been similar to the TMI-2 event in several important aspects. However, significant differences in plant status and operator response contributed to produce a much iess severe transient.

The staff concludes that satisfactory improvements in both design and emergency pro-cedures have been made since the 08-1 event and, that, the licensee has comolied witn tne requirement of Item (g) of tne Crcer.

CCNCL'JSICN We conclude that the actions described aoove fulfill the requirements of our Crder of May 15, 1979 in regard to Paragrapn (1) of Section IV.

The licensee having cet the requirements of Paragraph (1) may restart CS-1 as provided by Paragrapn (2).

Paragrach (3) of Section IV of the Orcer remains in force 3

y,s.,

u t,. _..

,=we,

. ~

until the long term ::todifications set forth in Section II of the Order are ccepleted and approved by the NRC.

( D [ **

  • O L 0 s',

. REFERENCES 1.

Letter from J. H. Taylor (B&W) to R. J. Mattson (NRC) transmitting report entitled, " Evaluation of Transient Behavior and Small Reactor Cocaint System Breaks in the 177 Fuel Assembly Plant,"

dated May 7, 1979.

2.

Lettar from J. H. Taylor (3&W) to R. J. Mattson (NRC) transmitting revised Acpendix 1. " Natural Circulation in S&W Operating Plants (Revision 1),"

dated May 3, 1979.

3.

Le tar from J. H. Taylor (S&W) to R. J. Mattson (NRC) transmitting addi-tienal information regarding Appendix 2, " Steam Generator Tube Thermal Stress Evaluation," to recort identified in Itc.n 2 acove, dated May 10, 19~9.

4 Letter from J. H. Taylor (3&W) to R. J. Mattson (NRC), providing an analysis for "Small Break in the Pressurizer (PORV) with no Auxiliary Feecwater and Single Failure of the ECCS," identified as Supplements 1 and 2 to Section 6.0 of report in Itam 2, dated May 12, 1979.

5.

Lettar from J. H. Taylor (S&W) to R. J. Mattson (NRC), providing Sucplement 3 to Section 5 of report in Itam 2, dated May 24, 1979.

5.

Letter from Lowell E. Roe (TECO) to Mr. Robert W. Reid (NRC) dated May 22, 1979, providing Volume III to Reference 1 for the raised loop plant.

' x',

in c, Na

..-.w..

.s 7.

Letter frcm Lowell E. Roe (TECO) to Mr. Robert W. Reid (NRC) dated May 23, 1979.

S.

Letter from Lowell E. Roe (TECO-Serial No. 517) to Harold R. Centon (CNRR) cated June 15, 1979.

9.

Letter from Lowell E. Roe (TECO) to Mr. Rccert W. Reid (NRC) dated Decemoer 22, 1978.

U d(u.':. : -

i m----

om