/03L-0:on 790912,root Valves Not Verified in Proper Position.Caused by Temporary Change in Procedures to Verify Proper Position in Accordance W/Plant Administrative Controls.Double Verification Program Initiated
ML19209C614
Person / Time
Site: FitzPatrick 
Issue date: 10/12/1979
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19209C609 List:
References
LER-79-072-03L, LER-79-72-3L, NUDOCS 7910160485
Download: ML19209C614 (2)


LER-1979-072, /03L-0:on 790912,root Valves Not Verified in Proper Position.Caused by Temporary Change in Procedures to Verify Proper Position in Accordance W/Plant Administrative Controls.Double Verification Program Initiated
Event date:
Report date:
3331979072R03 - NRC Website

text

(7 77) v. a..ucLc.,*n H ebuL A I UH Y COMMISSION LICENSER; EVENT REPORT CONTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

l Nl Yl Jl A Fj i jgl 0 l 0 l - l 0 0l0l0)-l0[0l0 4l1l1l1l1 gj l

l o

i 7

8 9 L.CENSEE COGE 14 15 LICENSE NUMBER 43 26 LICENSE TYPE Jo 67 CAT 58 CON'T R

o i

i l

i l

i l

3O R 7

8 60 61 DOCKE T NUMBER 6d 63 EV EN1 (./ k /i 14 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBAELE CONSEQUENCES h g

Please See Attachment L

i o

3 o

a l I

o s I l

o 6

l J

O 7

[

o a i l

7 8 9 80 SYSTEV

CAUSE

CAUSE COVP.

VALVE CODE CODE SUBCODE MP NEN CO SU SUB DE l'IBl@ I^l@ lxlg lZ;

[

l Z,g,BCp,Eg, g, g o

9 7

8 9

10 11 12 13 Id 19 20 SEQUE NTI A L OCCU R R E NCE REFORT R E VISION EVENT YEAR REPOR T NO.

CODE TYP e O.

O,"LE R a0uTN'

_I 719 l-1 L I 71 'l l'l l

13I l' EI l----I I

I 21 22 23 24

~6 27 28 29 30 31 32 T E A TC ON PL ANT lxlgl4 xjg gg gg l O l }R l l gg l ;g l

[g l A{L

. "! [g H

S8 O

FOR B.

S PP IE AC 33 J

35 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h i

o l Plesse See Attachment I

i i

I g

i 2

g t i l 31 l I

i 4

i l

7 8 9 80 ST S

3 l gg [0,(3/Enl4lgl OTHER STATUS IS O RY OtSCpV ER iPTION NA l

l D lg, l&E Inspect son 3ES l,

l ACTivlTY CON TENT RELEASED OF RE LE ASE AMOUNT OF ACTIVITY LOCATION CF RELE ASE Qj @ l Z [gl NA l

l NA i

6 l

PE RSONNE t, f XPOS ES NUVBE R TYPE

DESCRIPTION

l 0 l 0 l 0 l@lZ l@l NW i

7 l

PERSONNE L INJUR c5 otSCRiPTiONh NUveER li la l l 0l 0 l 0l@[

NA l

7 8 9 11 12 LOSS OF OR DAVAGE TO FACILITY 80 TYPE O E SC RIP TIO N h

4 l i l 9 l l Zl@l NA a7 l

U 7

8 9 iO g/p3 80 ISSUE @oESCRiPTiON @ 7910160 7 9

/

NRC USE ONLY lN l l

NA 2 o l

lllllllll ll l-7 8

'J 10 m

68 69 80 &

W. Verne Childs O

315-342-3840 o

NAVE OF PAEPARER PHON E-

POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRICK NLCLEAR POWER PLANT DOCKET NO. 50-333 ATTACHMENT TO LER 79-072/03L-0 Page 1

of I

During normal operation and during the course of ISE Inspection 79-14, it was noted that certain instrument root valves had not been verified in the proper position prior to the plant startup initiated on September 3,1979 Investigation revealed that the procedures intended to provide the verifi-cation of proper instrument root valve positions had been changed in accordance with the plant's approved administrative controls prior to the initiation of the reactor startup. As a result of the temporary change to these procedures a number of valves were deleted because the individuals making the changes to the procedure erroneous 1y understood that verification of the valve position was accomplished by a seperate valve lineup conducted by another department.

These actions re-sulted in a breakdown of the administrative controls required by Technical Specifi-cations Appendix A, Paragraph 6.8.

Double verification of proper instrument root valve position was immediately initiated and the plant was maintained in a steady state operating condition until this double verification could be completed.

In addition, the valve lineup proce-dures fo r i ns t rumen t root, valves of both the Operations and Instrumentation and Control Departments were compared and checked against each other as well as various plant drawings to provide assurance of a complete and accurate verification. The completion of these checks indicated that, with one exception, the instrument root valves were properly posi tioned. A non-safety related Quality Assurance Category 11 valve associated with a pressure switch which monitors pressure between two motor operated valves in Core Spray System "A" was the only va!ve found out of its normal position. The instruments purpose is to alert the operator (via an annunciator) of a high pressure condition which may indicate valve leakage.

Since the double verification of proper valve position was completed and no signi ficant deviations were found, the event did not represent any signi ficant hazard to the public health and safety.