Sample ID Parameter Method Lab Result 1.96 s Error of Sample Duplicate Lab Result 1.96 s Error of Sample Z-Score Fail if Z-score >
2.57 UNC-FSS-LDA-013 Uranium-238 Alpha Spec.
0.51 0.34 0.44 0.32 0.29 Pass UNC-FSS-SR-003 Uranium-233/234 Alpha Spec.
0.41 0.33 0.47 0.42 0.24 Pass UNC-FSS-SR-003 Uranium-235/236 Alpha Spec.
-0.05 0.14 0.08 0.17 1.19 Pass UNC-FSS-SR-035B Americium-241 Gamma Spec.
-0.03 0.08
-0.03 0.15 0.05 Pass UNC-FSS-SR-035B Antimony-124 Gamma Spec.
0.00 0.06
-0.01 0.12 0.08 Pass UNC-FSS-SR-035B Antimony-125 Gamma Spec.
0.01 0.03 0.01 0.07 0.17 Pass UNC-FSS-SR-035B Barium-133 Gamma Spec.
0.02 0.02
-0.01 0.04 1.51 Pass UNC-FSS-SR-035B Barium-140 Gamma Spec.
-2.92 4.49 3.12 8.31 1.25 Pass UNC-FSS-SR-035B Beryllium-7 Gamma Spec.
0.05 0.30
-0.40 0.58 1.32 Pass UNC-FSS-SR-035B Bismuth-212 Gamma Spec.
0.00 0.34 0.00 0.58 0.00 Pass UNC-FSS-SR-035B Bismuth-214 Gamma Spec.
0.51 0.08 0.58 0.14 0.85 Pass UNC-FSS-SR-035B Cerium-139 Gamma Spec.
0.00 0.02 0.01 0.03 0.26 Pass UNC-FSS-SR-035B Cerium-141 Gamma Spec.
0.09 0.11
-0.04 0.21 1.05 Pass UNC-FSS-SR-035B Cerium-144 Gamma Spec.
-0.04 0.10
-0.24 0.18 1.94 Pass UNC-FSS-SR-035B Cesium-134 Gamma Spec.
0.00 0.03 0.03 0.04 1.15 Pass UNC-FSS-SR-035B Cesium-136 Gamma Spec.
1.12 1.57 2.88 2.83 1.07 Pass UNC-FSS-SR-035B Cesium-137 Gamma Spec.
0.00 0.01
-0.01 0.03 0.59 Pass UNC-FSS-SR-035B Chromium-51 Gamma Spec.
0.34 0.81 0.33 1.63 0.01 Pass UNC-FSS-SR-035B Cobalt-56 Gamma Spec.
-0.02 0.03 0.06 0.06 2.11 Pass UNC-FSS-SR-035B Cobalt-57 Gamma Spec.
0.00 0.01
-0.01 0.02 1.00 Pass UNC-FSS-SR-035B Cobalt-58 Gamma Spec.
-0.05 0.03
-0.02 0.06 0.90 Pass UNC-FSS-SR-035B Cobalt-60 Gamma Spec.
0.01 0.02
-0.02 0.03 1.87 Pass UNC-FSS-SR-035B Europium-152 Gamma Spec.
0.00 0.05 0.02 0.08 0.46 Pass UNC-FSS-SR-035B Europium-154 Gamma Spec.
0.00 0.04
-0.04 0.08 0.75 Pass UNC-FSS-SR-035B Europium-155 Gamma Spec.
0.04 0.04 0.08 0.08 0.91 Pass UNC-FSS-SR-035B Iridium-192 Gamma Spec.
-0.01 0.03
-0.02 0.05 0.36 Pass UNC-FSS-SR-035B Iron-59 Gamma Spec.
-0.03 0.09
-0.03 0.16 0.06 Pass UNC-FSS-SR-035B Lead-210 Gamma Spec.
-0.07 2.20
-1.19 5.18 0.39 Pass UNC-FSS-SR-035B Lead-212 Gamma Spec.
1.18 0.13 1.11 0.15 0.70 Pass UNC-FSS-SR-035B Lead-214 Gamma Spec.
0.69 0.10 0.73 0.16 0.36 Pass UNC-FSS-SR-035B Manganese-54 Gamma Spec.
0.02 0.02 0.02 0.03 0.37 Pass UNC-FSS-SR-035B Mercury-203 Gamma Spec.
0.06 0.05 0.05 0.09 0.22 Pass UNC-FSS-SR-035B Neodymium-147 Gamma Spec.
14.30 17.20
-26.50 32.20 2.19 Pass UNC-FSS-SR-035B Neptunium-239 Gamma Spec.
-0.22 0.16 0.34 0.31 3.16 Fail UNC-FSS-SR-035B Niobium-94 Gamma Spec.
0.02 0.01 0.01 0.03 0.85 Pass UNC-FSS-SR-035B Niobium-95 Gamma Spec.
0.03 0.03 0.05 0.06 0.47 Pass UNC-FSS-SR-035B Potassium-40 Gamma Spec.
9.00 1.03 8.32 1.13 0.87 Pass
Sample ID Parameter Method Lab Result 1.96 s Error of Sample Duplicate Lab Result 1.96 s Error of Sample Z-Score Fail if Z-score >
2.57 UNC-FSS-SR-035B Promethium-144 Gamma Spec.
0.00 0.02
-0.01 0.03 0.64 Pass UNC-FSS-SR-035B Promethium-146 Gamma Spec.
0.00 0.02 0.02 0.03 0.97 Pass UNC-FSS-SR-035B Radium-226 Gamma Spec.
0.51 0.08 0.58 0.14 0.85 Pass UNC-FSS-SR-035B Radium-228 Gamma Spec.
0.99 0.18 1.06 0.26 0.44 Pass UNC-FSS-SR-035B Ruthenium-106 Gamma Spec.
0.03 0.13
-0.08 0.23 0.78 Pass UNC-FSS-SR-035B Silver-110m Gamma Spec.
0.00 0.01 0.00 0.03 0.32 Pass UNC-FSS-SR-035B Sodium-22 Gamma Spec.
0.00 0.02
-0.01 0.03 0.71 Pass UNC-FSS-SR-035B Thallium-208 Gamma Spec.
0.33 0.05 0.29 0.07 0.82 Pass UNC-FSS-SR-035B Thorium-234 Gamma Spec.
0.48 1.07
-0.09 1.29 0.67 Pass UNC-FSS-SR-035B Tin-113 Gamma Spec.
0.00 0.02
-0.02 0.05 0.80 Pass UNC-FSS-SR-035B Uranium-235 Gamma Spec.
-0.06 0.09 0.12 0.16 2.01 Pass UNC-FSS-SR-035B Uranium-238 Gamma Spec.
0.48 1.07
-0.09 1.29 0.67 Pass UNC-FSS-SR-035B Yttrium-88 Gamma Spec.
0.00 0.02 0.03 0.04 1.27 Pass UNC-FSS-SR-035B Zinc-65 Gamma Spec.
0.03 0.04
-0.01 0.08 0.82 Pass UNC-FSS-SR-035B Zirconium-95 Gamma Spec.
0.11 0.06 0.07 0.11 0.54 Pass UNC-FSS-XY-013 Actinium-228 Gamma Spec.
1.09 0.27 1.06 0.21 0.17 Pass UNC-FSS-XY-013 Antimony-124 Gamma Spec.
0.03 0.04
-0.01 0.07 0.96 Pass UNC-FSS-XY-013 Beryllium-7 Gamma Spec.
-0.14 0.33 0.02 0.28 0.71 Pass UNC-FSS-XY-013 Bismuth-212 Gamma Spec.
0.00 0.55 0.00 0.57 0.00 Pass UNC-FSS-XY-013 Bismuth-214 Gamma Spec.
0.60 0.11 0.62 0.11 0.25 Pass UNC-FSS-XY-013 Cerium-139 Gamma Spec.
0.01 0.02 0.02 0.02 0.58 Pass UNC-FSS-XY-013 Cerium-141 Gamma Spec.
0.02 0.13 0.00 0.12 0.27 Pass UNC-FSS-XY-013 Cerium-144 Gamma Spec.
0.01 0.14 0.04 0.15 0.32 Pass UNC-FSS-XY-013 Cesium-134 Gamma Spec.
0.04 0.02 0.04 0.03 0.11 Pass UNC-FSS-XY-013 Cesium-136 Gamma Spec.
-0.62 1.32
-0.25 0.38 0.52 Pass UNC-FSS-XY-013 Cesium-137 Gamma Spec.
0.00 0.02
-0.03 0.02 1.54 Pass UNC-FSS-XY-013 Chromium-51 Gamma Spec.
-0.15 0.84
-0.09 0.51 0.11 Pass UNC-FSS-XY-013 Cobalt-56 Gamma Spec.
-0.01 0.03 0.02 0.03 1.43 Pass UNC-FSS-XY-013 Cobalt-57 Gamma Spec.
-0.01 0.02
-0.01 0.02 0.33 Pass UNC-FSS-XY-013 Cobalt-58 Gamma Spec.
0.00 0.03
-0.02 0.03 0.76 Pass UNC-FSS-XY-013 Cobalt-60 Gamma Spec.
0.02 0.02 0.02 0.02 0.52 Pass UNC-FSS-XY-013 Europium-152 Gamma Spec.
-0.01 0.06 0.04 0.06 1.33 Pass UNC-FSS-XY-013 Europium-154 Gamma Spec.
-0.05 0.06
-0.03 0.06 0.43 Pass UNC-FSS-XY-013 Europium-155 Gamma Spec.
0.08 0.06 0.06 0.08 0.28 Pass UNC-FSS-XY-013 Iridium-192 Gamma Spec.
0.01 0.03 0.00 0.03 0.52 Pass UNC-FSS-XY-013 Iron-59 Gamma Spec.
-0.09 0.11 0.02 0.08 1.53 Pass UNC-FSS-XY-013 Lead-210 Gamma Spec.
1.66 2.76 0.63 3.50 0.45 Pass
Sample ID Parameter Method Lab Result 1.96 s Error of Sample Duplicate Lab Result 1.96 s Error of Sample Z-Score Fail if Z-score >
2.57 UNC-FSS-XY-013 Lead-212 Gamma Spec.
0.95 0.12 1.05 0.13 1.15 Pass UNC-FSS-XY-013 Lead-214 Gamma Spec.
0.69 0.12 0.75 0.12 0.63 Pass UNC-FSS-XY-013 Manganese-54 Gamma Spec.
0.02 0.02 0.00 0.02 1.35 Pass UNC-FSS-XY-013 Mercury-203 Gamma Spec.
0.00 0.05 0.02 0.04 0.80 Pass UNC-FSS-XY-013 Neodymium-147 Gamma Spec.
3.74 12.90
-0.57 2.68 0.64 Pass UNC-FSS-XY-013 Neptunium-239 Gamma Spec.
0.04 0.21 0.12 0.28 0.43 Pass UNC-FSS-XY-013 Niobium-94 Gamma Spec.
0.00 0.02 0.00 0.02 0.09 Pass UNC-FSS-XY-013 Niobium-95 Gamma Spec.
0.06 0.04 0.06 0.04 0.13 Pass UNC-FSS-XY-013 Potassium-40 Gamma Spec.
8.37 1.09 10.30 1.29 2.24 Pass UNC-FSS-XY-013 Promethium-144 Gamma Spec.
0.00 0.02 0.00 0.02 0.08 Pass UNC-FSS-XY-013 Promethium-146 Gamma Spec.
-0.01 0.02 0.01 0.02 1.22 Pass UNC-FSS-XY-013 Radium-226 Gamma Spec.
0.60 0.11 0.62 0.11 0.25 Pass UNC-FSS-XY-013 Radium-228 Gamma Spec.
0.99 0.18 1.06 0.21 0.51 Pass UNC-FSS-XY-013 Ruthenium-106 Gamma Spec.
-0.04 0.17 0.07 0.19 0.80 Pass UNC-FSS-XY-013 Silver-110m Gamma Spec.
0.01 0.03 0.01 0.03 0.06 Pass UNC-FSS-XY-013 Sodium-22 Gamma Spec.
-0.02 0.02
-0.01 0.02 0.58 Pass UNC-FSS-XY-013 Thallium-208 Gamma Spec.
0.25 0.04 0.28 0.05 1.13 Pass UNC-FSS-XY-013 Thorium-234 Gamma Spec.
0.27 0.88 0.37 2.01 0.08 Pass UNC-FSS-XY-013 Tin-113 Gamma Spec.
0.00 0.03 0.02 0.03 0.97 Pass UNC-FSS-XY-013 Uranium-235 Gamma Spec.
1.25 0.39 1.47 0.38 0.80 Pass UNC-FSS-XY-013 Uranium-238 Gamma Spec.
1.05 1.40 0.37 2.01 0.55 Pass UNC-FSS-XY-013 Yttrium-88 Gamma Spec.
0.01 0.02 0.00 0.02 0.67 Pass