UNC New Haven Decommissioning - Effluent Air Sample Results Detector:

4/6/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3561 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 60 60 Isotope 10CFR20 Occupational Effluent U-234 1.00E-14 9/1/11 10:00 9/1/11 14:45 09/07/11 288 15.0 14 0

1.00 1

1.46E-14 1.46 4.67E-16 9/22/11 7:25 9/22/11 15:02 09/27/11 2882 15.0 15 0.3 1.00 0

1.21E-16 0.01 3.87E-16 9/22/11 7:25 9/22/11 15:02 09/27/11 2882 15.0 25 0.3 1.00 1

1.17E-15 0.12 3.87E-16 9/14/11 8:44 9/16/11 15:30 10/03/11 860 15.0 17 0.1 1.00 1

4.34E-15 0.43 8.14E-16 9/14/11 8:44 9/16/11 15:30 09/27/11 860 15.0 18 0.3 1.00 0

1.46E-15 0.15 1.30E-15 9/23/11 7:40 9/26/11 14:10 10/03/11 774 15.0 6

0.1 1.00 0

5.39E-16 0.05 9.05E-16 9/23/11 7:40 9/26/11 14:10 10/03/11 774 15.0 11 0.1 1.00 0

2.49E-15 0.25 9.05E-16 9/27/11 8:40 9/27/11 15:20 10/03/11 400 15.0 6

0.1 1.00 0

1.04E-15 0.10 1.75E-15 9/27/11 8:40 9/27/11 15:20 10/03/11 400 15.0 7

0.1 1.00 0

1.80E-15 0.18 1.75E-15 9/28/11 7:50 9/30/11 15:00 10/04/11 1136 15.0 13 0.1 1.00 1

2.22E-15 0.22 6.16E-16 9/28/11 7:50 9/30/11 15:00 10/04/11 1136 15.0 8

0.1 1.00 0

8.98E-16 0.09 6.16E-16 10/3/11 9:53 10/7/11 16:04 10/11/11 2106 15.0 13 0.2 1.00 0

5.39E-16 0.05 4.44E-16 10/3/11 9:53 10/7/11 16:04 10/11/11 2106 15.0 13 0.2 1.00 0

5.39E-16 0.05 4.44E-16 10/10/11 7:40 10/12/10 14:15 10/20/11 1288 15.0 14 0.2 1.00 0

1.12E-15 0.11 7.25E-16 10/10/11 7:40 10/12/10 14:15 10/20/11 1288 15.0 9

0.2 1.00 0

-5.40E-17

-0.01 7.25E-16 10/17/11 7:40 10/18/11 15:30 11/09/11 860 15.0 8

0 1.00 0

2.80E-15 0.28 1.56E-16 10/24/11 7:20 10/28/11 15:04 11/09/11 1768 15.0 18 0

1.00 1

3.07E-15 0.31 7.61E-17 11/7/11 8:00 11/11/11 15:00 11/22/11 1696 15.0 14 0.4 1.00 0

-7.93E-16

-0.08 7.46E-16 11/7/11 8:00 11/11/11 15:00 11/22/11 1696 15.0 16 0.4 1.00 0

-4.37E-16

-0.04 7.46E-16 11/14/11 10:00 11/18/11 15:00 11/30/11 1376 15.0 24 0.2 1.00 1

3.23E-15 0.32 6.79E-16 11/14/11 10:00 11/18/11 15:00 11/29/11 1376 15.0 23 0.3 1.00 1

2.00E-15 0.20 8.10E-16 11/21/11 7:45 11/23/11 16:00 11/29/11 1396 15.0 22 0.3 1.00 0

1.76E-15 0.18 7.98E-16 11/21/11 7:45 11/23/11 16:00 11/29/11 1396 15.0 31 0.3 1.00 1

3.70E-15 0.37 7.98E-16 12/16/11 7:30 12/16/11 14:30 01/05/12 721 15.0 81 0.2 1.00 4

3.00E-14 3.00 1.30E-15 12/16/11 7:30 12/16/11 14:30 01/05/12 721 15.0 63 0.2 1.00 3

2.25E-14 2.25 1.30E-15 1/5/12 8:51 1/5/12 14:04 01/11/12 295 15.0 44 0.1 1.00 2

4.02E-14 4.02 2.37E-15 2/13/12 0800 2/16/12 1500 02/21/12 1525 15.0 9

0.5 1.00

-1

-2.78E-15

-0.28 9.18E-16 2/6/12 0830 2/10/12 1410 02/21/12 910 15.0 10 0.5 1.00

-1

-4.33E-15

-0.43 1.54E-15 2/27/12 0930 3/2/12 1310 03/05/12 645 15.0 2

0.2 1.00 0

-3.38E-15

-0.34 1.45E-15 2/27/12 0930 3/2/12 1310 03/05/12 645 15.0 1

0.2 1.00

-1

-3.84E-15

-0.38 1.45E-15 2/22/12 0815 2/24/12 1140 03/05/12 665 15.0 10 0.2 1.00 0

3.49E-16 0.03 1.41E-15 2/22/12 0815 2/24/12 1140 03/05/12 665 15.0 10 0.2 1.00 0

3.49E-16 0.03 1.41E-15 3/8/12 0740 3/8/12 1515 03/16/12 455 15.0 0

0.2 1.00

-1

-6.11E-15

-0.61 2.05E-15 3/8/12 0740 3/8/12 1515 03/16/12 455 15.0 4

0.2 1.00 0

-3.46E-15

-0.35 2.05E-15 3/23/12 0930 3/23/12 1405 03/28/12 275 15.0 9

0.1 1.00 0

4.80E-15 0.48 2.55E-15 3/26/12 0800 3/26/12 1300 04/03/12 300 15.0 3

0.4 1.00

-1

-1.55E-14

-1.55 4.22E-15 3/26/12 0800 3/26/12 1300 04/03/12 300 15.0 3

0.4 1.00

-1

-1.55E-14

-1.55 4.22E-15 4.67 Hi-Volume Filter Area Factor (Adjusts for Portion of Filter that is Counted Only)

HV-16833-X-Ray Read HV-16833-DeconRm-O/s HV-16833-DeconRm-O/s HV-16833-DeconRm-O/s HV-16832-E-Laydown HV-16833-W-Laydown HV-16832-X-Ray Read HV-16833-X-Ray Read HV-16832-X-Ray Read Hi-Vol 16829 Hi-Vol 16829 Hi-Vol16833 Hi-Vol 16829 Hi-Vol 16832 Xray HiVol Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 16829 Hi-Vol 16833 Hi-Vol 16833 Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Hi-Vol 18204 Trench West Hi-Vol 16827 Trench East Fraction of Environ.

Effluent Limit Alpha Alpha MDA (uCi/cc)

Downwind Perimeter - Sewer Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (CFM)

Sample Gross Alpha (Counts)

Limiting Alpha Isotope of Concern Counting Instrument:

3030E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Page 1 of 8

UNC New Haven Decommissioning - Effluent Air Sample Results Detector:

6/7/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3434 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occupational Effluent U-234 1.00E-14 8/23/11 9:58 8/24/11 15:00 08/30/11 711 80.0 2

0.10 1.00 0

3.69E-15 0.37 5.23E-15 8/25/11 8:13 8/29/11 15:00 08/30/11 1192 80.0 8

0.10 1.00 3

1.29E-14 1.29 3.12E-15 9/1/11 7:30 9/2/11 14:35 09/06/11 835 77.5 6

0.00 1.00 2

1.58E-14 1.58 8.83E-16 9/6/11 7:31 9/7/11 15:10 09/08/11 913 82.5 11 0.10 1.00 4

2.32E-14 2.32 3.95E-15 9/14/11 7:31 9/15/11 15:12 09/21/11 922 82.5 2

0.00 1.00 1

4.48E-15 0.45 7.51E-16 9/16/11 7:35 9/19/11 15:15 09/21/11 916 75.0 5

0.00 1.00 2

1.24E-14 1.24 8.32E-16 9/20/11 8:15 9/26/11 15:15 09/29/11 818 80.0 2

0.00 1.00 1

5.21E-15 0.52 8.73E-16 11/4/11 10:15 11/4/11 15:10 11/09/11 295 80.0 9

0.00 1.00 3

6.50E-14 6.50 2.42E-15 11/9/11 8:00 11/10/11 15:15 11/15/11 900 80.0 10 0.00 1.00 4

2.37E-14 2.37 7.94E-16 11/15/11 7:30 11/15/11 14:04 11/22/11 394 75.0 1

0.10 1.00 0

1.33E-15 0.13 1.01E-14 11/16/11 7:30 11/16/11 15:16 11/22/11 466 80.0 1

0.10 1.00 0

1.06E-15 0.11 7.98E-15 11/17/11 7:30 11/18/11 15:16 11/22/11 929 80.0 6

0.10 1.00 2

1.20E-14 1.20 4.00E-15 11/21/11 7:30 11/22/11 15:16 11/29/11 855 80.0 4

0.00 1.00 2

9.97E-15 1.00 8.35E-16 11/23/11 7:30 11/28/11 15:10 11/29/11 790 75.0 0

0.00 1.00 0

0.00E+00 0.00 9.64E-16 11/29/11 7:30 11/30/11 15:10 12/05/11 765 75.0 0

0.20 1.00

-1

-4.57E-15

-0.46 6.92E-15 12/6/11 7:30 12/8/11 15:10 12/14/11 710 75.0 2

0.30 1.00 0

-9.85E-16

-0.10 8.89E-15 12/9/11 7:30 12/12/11 15:30 12/14/11 831 75.0 9

0.30 1.00 3

1.83E-14 1.83 7.59E-15 12/13/11 7:30 12/14/11 15:30 12/22/11 831 75.0 2

0.60 1.00

-1

-7.16E-15

-0.72 1.04E-14 12/15/11 7:30 12/16/11 15:30 12/22/11 831 75.0 0

0.60 1.00

-2

-1.26E-14

-1.26 1.04E-14 12/19/11 7:30 12/20/11 15:30 12/22/11 831 75.0 2

0.60 1.00

-1

-7.16E-15

-0.72 1.04E-14 12/23/12 7:30 12/23/11 15:05 01/05/12 365 75.0 0

0.30 1.00

-1

-1.44E-14

-1.44 1.73E-14 1/3/12 7:30 1/4/12 15:05 01/09/12 730 75.0 4

0.20 1.00 1

7.67E-15 0.77 7.25E-15 1/5/12 7:30 1/6/12 15:05 01/09/12 730 75.0 3

0.20 1.00 1

4.55E-15 0.46 7.25E-15 1/9/12 7:30 1/10/12 15:05 01/12/12 730 75.0 4

0.10 1.00 1

1.01E-14 1.01 5.43E-15 1/11/12 0730 1/12/12 1505 01/16/12 730 75.0 2

0.20 1.00 0

1.44E-15 0.14 7.25E-15 1/13/12 0730 1/13/12 1505 01/16/12 365 75.0 0

0.20 1.00

-1

-9.58E-15

-0.96 1.45E-14 1/16/12 0730 1/17/12 1505 01/23/12 730 75.0 3

0.30 1.00 0

2.16E-15 0.22 8.64E-15 1/18/12 0730 1/19/12 1505 01/23/12 730 75.0 4

0.30 1.00 1

5.27E-15 0.53 8.64E-15 1/20/12 0730 1/20/12 1505 01/23/12 365 75.0 1

0.30 1.00 0

-8.15E-15

-0.81 1.73E-14 1/23/12 0730 1/24/12 1505 01/27/12 730 75.0 2

0.20 1.00 0

1.44E-15 0.14 7.25E-15 1/25/12 0730 1/26/12 1505 01/30/12 730 75.0 1

0.30 1.00 0

-4.07E-15

-0.41 8.64E-15 1/27/12 0730 1/27/12 1505 01/30/12 365 75.0 2

0.30 1.00 0

-1.92E-15

-0.19 1.73E-14 1/30/12 0730 1/31/12 1505 02/06/12 730 75.0 2

0.40 1.00 0

-3.35E-15

-0.34 9.82E-15 2/1/12 0730 2/2/12 1505 02/06/12 730 75.0 2

0.40 1.00 0

-3.35E-15

-0.34 9.82E-15 2/3/12 0730 2/3/12 1505 02/06/12 365 75.0 3

0.40 1.00 0

-4.79E-16

-0.05 1.96E-14 2/6/12 0730 2/7/12 1505 02/10/12 730 75.0 0

0.10 1.00 0

-2.40E-15

-0.24 5.43E-15 2/8/12 0730 2/9/12 1505 02/13/12 730 75.0 1

0.10 1.00 0

7.19E-16 0.07 5.43E-15 2/10/12 0730 2/10/12 1505 02/13/12 365 75.0 3

0.10 1.00 1

1.39E-14 1.39 1.09E-14 2/13/12 0730 2/14/12 1505 02/20/12 730 75.0 3

0.30 1.00 0

2.16E-15 0.22 8.64E-15 2/15/12 0730 2/16/12 1505 02/20/12 730 75.0 1

0.30 1.00 0

-4.07E-15

-0.41 8.64E-15 2/17/12 0730 2/17/12 1505 02/20/12 365 75.0 1

0.30 1.00 0

-8.15E-15

-0.81 1.73E-14 2/20/12 0730 2/21/12 1505 02/24/12 730 75.0 1

0.20 1.00 0

-1.68E-15

-0.17 7.25E-15 2/22/12 0730 2/23/12 1505 02/27/12 730 75.0 1

0.40 1.00

-1

-6.47E-15

-0.65 9.82E-15 2/24/12 0730 2/24/12 1505 02/27/12 365 75.0 0

0.40 1.00

-1

-1.92E-14

-1.92 1.96E-14 2/27/12 0730 2/28/12 1505 03/02/12 730 75.0 3

0.10 1.00 1

6.95E-15 0.69 5.43E-15 2/29/12 0730 3/1/12 1505 03/05/12 730 75.0 4

0.10 1.00 1

1.01E-14 1.01 5.43E-15 3/2/12 0730 3/2/12 1505 03/05/12 365 75.0 2

0.10 1.00 0

7.67E-15 0.77 1.09E-14 3/5/12 0730 3/6/12 1505 03/13/12 730 75.0 1

0.10 1.00 0

7.19E-16 0.07 5.43E-15 3/7/12 0730 3/8/12 1505 03/13/12 730 75.0 1

0.10 1.00 0

7.19E-16 0.07 5.43E-15 3/9/12 0730 3/9/12 1505 03/13/12 365 75.0 2

0.10 1.00 0

7.67E-15 0.77 1.09E-14 3/12/12 0730 3/13/12 1505 03/16/12 730 75.0 1

0.30 1.00 0

-4.07E-15

-0.41 8.64E-15 3/19/12 0730 3/20/12 1505 03/26/12 730 75.0 0

0.20 1.00

-1

-4.79E-15

-0.48 7.25E-15 3/21/12 0730 3/22/12 1505 03/26/12 730 75.0 0

0.20 1.00

-1

-4.79E-15

-0.48 7.25E-15 3/23/12 0730 3/23/12 1505 03/26/12 365 75.0 3

0.20 1.00 1

9.10E-15 0.91 1.45E-14 3/26/12 0730 3/27/12 1505 04/03/12 730 75.0 0

0.10 1.00 0

-2.40E-15

-0.24 5.43E-15 3/28/12 0730 3/29/12 1505 04/03/12 730 75.0 3

0.10 1.00 1

6.95E-15 0.69 5.43E-15 4/2/12 0730 4/3/12 1505 04/09/12 730 75.0 3

0.20 1.00 1

4.55E-15 0.46 7.25E-15 4/4/12 0730 4/5/12 1505 04/09/12 730 75.0 3

0.20 1.00 1

4.55E-15 0.46 7.25E-15 4/9/12 0730 4/10/12 1505 04/16/12 730 75.0 4

0.40 1.00 0

2.88E-15 0.29 9.82E-15 4/11/12 0730 4/12/12 1505 04/16/12 730 75.0 2

0.40 1.00 0

-3.35E-15

-0.34 9.82E-15 4/13/12 0730 4/13/12 1505 04/16/12 365 75.0 2

0.40 1.00 0

-6.71E-15

-0.67 1.96E-14 4/16/12 0730 4/17/12 1505 04/23/12 730 75.0 3

0.20 1.00 1

4.55E-15 0.46 7.25E-15 4/18/12 7:30 4/19/12 1505 04/23/12 730 75.0 3

0.20 1.00 1

4.55E-15 0.46 7.25E-15 4/19/12 7:30 4/20/12 1506 04/23/12 730 75.0 5

0.20 1.00 1

1.08E-14 1.08 7.25E-15 4/23/12 7:45 4/24/12 1309 04/25/12 897 75.0 8

0.30 1.00 2

1.44E-14 1.44 7.04E-15 4/25/12 7:30 4/26/12 15:00 04/27/12 675 75.0 7

0.10 1.00 2

2.10E-14 2.10 5.87E-15 4/27/12 7:20 4/30/12 15:11 05/02/12 926 75.0 0

0.30 1.00

-1

-5.67E-15

-0.57 6.82E-15 5/1/12 7:30 5/2/12 15:00 05/03/12 815 75.0 4

0.10 1.00 1

9.01E-15 0.90 4.87E-15 5/3/12 7:30 5/4/12 15:00 05/09/12 740 75.0 1

0.40 1.00

-1

-6.38E-15

-0.64 9.69E-15 Counting Instrument:

2360 43-10-1 Cal. Date:

Serial #:

193635 PR202583 Cal. Due Date OK?

Limiting Alpha Isotope of Concern Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Fraction Environ.

Effluent Limit Alpha Alpha MDA (uCi/cc)

Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos LV-1 LV-1 3401 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 Asbestos Work Area LV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 AsbestosWorkAreaLV-1 Page 2 of 8

UNC New Haven Decommissioning - Effluent Air Sample Results Detector:

4/6/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3561 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occupational DAC /Effluent U-234 1.00E-14 8/30/11 7:30 8/31/11 15:00 09/06/11 910 80.0 5

0.10 1.00 2

9.56E-15 0.96 4.09E-15 9/8/11 7:35 9/8/11 15:15 09/13/11 910 72.5 3

0.20 1.00 1

3.64E-15 0.36 6.02E-15 9/13/11 7:30 9/14/11 15:15 09/15/11 930 72.5 4

0.00 1.00 1

9.76E-15 0.98 8.47E-16 10/28/11 7:38 11/1/11 15:10 11/02/11 905 80.0 2

0.30 1.00 0

-6.99E-16

-0.07 6.54E-15 11/2/11 8:00 11/3/11 15:15 11/7/711 879 80.0 7

0.10 1.00 2

1.46E-14 1.46 4.23E-15 11/7/11 7:46 11/8/11 15:15 11/14/11 920 80.0 4

0.20 1.00 1

5.50E-15 0.55 5.39E-15 11/11/11 7:30 11/14/11 15:10 11/18/11 920 75.0 2

0.10 1.00 0

2.93E-15 0.29 4.31E-15 12/1/11 7:30 12/2/11 15:10 12/06/11 901 75.0 4

0.30 1.00 1

4.12E-15 0.41 7.00E-15 Alpha Effluent exposure periods are based on the sum of each day's monitoring period Total Air Monitoring Hours 1568.73 Total Hours per Calendar Year (CY) 8760

%CY associated with UNC New Haven Effluent Emissions 17.91%

7.10E-15 1.00E-14 70.96%

17.91%

1.271 YES Weighted Average Air Concentration (uCi/cc)

DEL equivalent to 10 mrem/y

%DEL Estimated Exposure Duration as a % of full year Estimated Annual Dose (millirem) from Effluents Generated During Remediation Less than NESHAP Standard?

Asbestos Work Area 3401 Asbestos Work Area 2590A NOTES: 1) The Action Level concentrations are set to 20% of the values published in Columns I & II of Table 2 of 10CFR 20 Appendix B. The raw Appendix B values are equivalent to the radionuclide concentrations which if inhaled or ingested continuously over the course of a year, would produce a total effective dose equivalent (TEDE) of 50 millirem (mrem) per year. The reduction to 20% of these values allows consistency with the U.S Environmental Protection Agencys (USEPA) 10 mrem/yr standard for effluent releases published in 40 CFR Part 61, Sections 92 & 102 (NESHAP).

2) The effluent air filter samples on several days during remediation activities exceeded the environmental effluent limit of 10% of the applicable Derived Effluent Limit (DEL) (1.00E-14 microcuries per cubic centimeter [uCi/cc]). Run times and count times for filters were often not adequate to achieve the MDAs less than 10% of the applicable DEL. Therefore, an assessment was performed to compare the weighted average concentration to the DEL. As a conservative approach the weighted average air concentration uses the higher of the reported result or MDA for each sample.

Asbestos Work Area Clean Asbestos Work Area Clean Asbestos Work Area Clean Asbestos Work Area 2590A Asbestos Work Area 2590A Asbestos Work Area 2590A Counting Instrument:

3030E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Limiting Alpha Isotope of Concern Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Fraction Environ.

Effluent Limit Alpha Alpha MDA (uCi/cc)

Page 3 of 8

UNC New Haven Decommissioning - Work Area Air Sample Results Detector:

4/6/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3561 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 60 60 Isotope 10CFR20 Occupational DAC U-234 2.00E-11 3/23/12 0930 3/23/12 1405 03/28/12 275 15.0 3009 0.1 1.00 183 3.29E-12 0.16 2.55E-15 3/26/12 0800 3/26/12 1300 04/03/12 300 15.0 273 0.4 1.00 15 2.56E-13 0.01 4.22E-15 Detector:

6/7/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3434 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 60 60 Isotope 10CFR20 Occupational DAC U-234 2.00E-11 9/22/11 7:25 9/22/11 15:02 09/28/11 2882 15.0 15 0.1 1.00 1

1.13E-15 0.00 2.43E-16 10/17/11 7:40 10/18/11 15:30 11/09/11 860 15.0 14 0

1.00 1

5.09E-15 0.00 1.56E-16 10/24/11 7:20 10/28/11 15:04 11/09/11 1768 15.0 11 0

1.00 1

1.94E-15 0.00 7.61E-17 4/10/12 0950 4/10/12 1315 04/16/12 205 15.0 4

0.4 1.00

-1

-2.20E-14 0.00 6.17E-15 4/11/12 1000 4/11/12 1445 04/18/12 285 15.0 9

0.3 1.00 0

-5.31E-15 0.00 3.91E-15 4/12/12 0825 4/12/12 1400 04/18/12 335 15.0 6

0.3 1.00 0

-7.32E-15 0.00 3.33E-15 4/17/12 9:00 4/17/12 14:00 05/01/12 300 15.0 10 0.2 1.00 0

8.01E-16 0.00 3.11E-15 Detector:

6/7/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3434 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occupational DAC U-234 2.00E-11 8/23/11 9:57 8/24/11 15:00 08/30/11 712 72.5 7

0.10 1.00 2

2.06E-14 0.00 5.76E-15 8/25/11 8:13 8/29/11 15:00 08/30/11 1192 72.5 14 0.10 1.00 5

2.61E-14 0.00 3.44E-15 9/1/11 7:30 9/2/11 14:35 09/06/11 835 75.0 7

0.00 1.00 3

1.91E-14 0.00 9.12E-16 9/6/11 7:30 9/7/11 15:10 09/08/11 912 70.0 5

0.10 1.00 2

1.13E-14 0.00 4.66E-15 9/14/11 7:30 9/15/11 15:12 09/21/11 922 77.5 5

0.00 1.00 2

1.19E-14 0.00 8.00E-16 9/16/11 7:35 9/19/11 15:15 09/21/11 916 80.0 15 0.00 1.00 6

3.49E-14 0.00 7.80E-16 9/20/11 8:15 9/26/11 15:15 09/29/11 818 75.0 3

0.00 1.00 1

8.34E-15 0.00 9.31E-16 11/9/11 7:30 11/10/11 15:15 11/15/11 900 75.0 4

0.00 1.00 2

1.01E-14 0.00 8.46E-16 11/21/11 7:30 11/22/11 15:16 11/29/11 855 80.0 0

0.00 1.00 0

0.00E+00 0.00 8.35E-16 11/29/11 7:30 11/30/11 15:10 12/05/11 765 75.0 3

0.20 1.00 1

4.34E-15 0.00 6.92E-15 Counting Instrument:

2360 43-10-1 Cal. Date:

Serial #:

193635 PR202583 Cal. Due Date OK?

Limiting Alpha Isotope of Concern 4.67 Hi-Volume Filter Area Factor (Adjusts for Portion of Filter that is Counted Only)

Hi-Volume Filter Area Factor (Adjusts for Portion of Filter that is Counted Only)

Counting Instrument:

2360 43-10-1 Cal. Date:

Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (CFM)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Serial #:

193635 PR202583 Cal. Due Date OK?

Fraction of DAC Limit Alpha Alpha MDA (uCi/cc)

Hi-Vol 16827 Trench East Limiting Alpha Isotope of Concern Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

So Trench Soil Sampling Hi-Vol 1521 Trench West Hi-Vol 1521 Trench West SouthTrench DownHole#12 SoTrenchSoilSmple So TrenchSawCutting Flow Rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Fraction of DAC Limit Alpha Alpha MDA (uCi/cc)

Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 3401 Asbestos Work Area 2590A HV-16832-DeconRm-I/S HV-16832-DeconRm-I/S Fraction of DAC Limit Alpha Alpha MDA (uCi/cc)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (CFM)

Sample Gross Alpha (Counts)

Limiting Alpha Isotope of Concern 4.67 Counting Instrument:

3030E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Page 4 of 8

UNC New Haven Decommissioning - Work Area Air Sample Results Detector:

4/6/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3561 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occupational DAC U-234 2.00E-11 8/30/11 7:30 8/31/11 15:00 09/06/11 910 70.0 0

0.10 1.00 0

-1.99E-15 0.00 4.67E-15 9/8/11 7:36 9/8/11 15:16 09/13/11 910 80.0 2

0.20 1.00 0

1.04E-15 0.00 5.45E-15 9/13/11 7:30 9/14/11 15:15 09/15/11 930 80.0 10 0.00 1.00 4

2.21E-14 0.00 7.68E-16 10/28/11 7:40 11/1/11 11:55 11/02/11 705 75.0 1

0.30 1.00 0

-4.07E-15 0.00 8.95E-15 10/28/11 7:38 11/1/11 15:10 11/02/11 905 80.0 2

0.30 1.00 0

-6.99E-16 0.00 6.54E-15 11/2/11 8:02 11/3/11 15:15 11/07/11 883 75.0 3

0.10 1.00 1

5.54E-15 0.00 4.49E-15 11/2/11 8:00 11/3/11 15:15 11/7/711 879 80.0 7

0.10 1.00 2

1.46E-14 0.00 4.23E-15 11/7/11 7:45 11/8/11 15:15 11/14/11 918 75.0 5

0.20 1.00 1

8.27E-15 0.00 5.77E-15 11/7/11 7:46 11/8/11 15:15 11/14/11 920 80.0 4

0.20 1.00 1

5.50E-15 0.00 5.39E-15 11/11/11 7:30 11/14/11 15:10 11/18/11 920 75.0 2

0.10 1.00 0

2.93E-15 0.00 4.31E-15 11/11/11 7:30 11/14/11 15:10 11/18/11 920 82.5 7

0.10 1.00 2

1.35E-14 0.00 3.92E-15 12/1/11 7:30 12/2/11 15:10 12/06/11 901 75.0 1

0.30 1.00 0

-3.18E-15 0.00 7.00E-15 12/1/11 7:30 12/2/11 15:10 12/06/11 901 75.0 4

0.30 1.00 1

4.12E-15 0.00 7.00E-15 Detector:

4/30/2012 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3560 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occupational DAC /Effluent U-234 2.00E-11 5/28/12 7:00 6/1/12 15:00 06/06/12 2400 80.0 0

0.00 1.00 0

0.00E+00 0.00 2.98E-16 6/4/12 7:00 6/8/12 15:00 06/13/12 2400 80.0 3

0.30 1.00 0

5.93E-16 0.00 2.47E-15 6/11/12 7:00 6/15/12 15:00 06/20/12 2400 80.0 1

0.30 1.00 0

-1.12E-15 0.00 2.47E-15 6/18/12 7:00 6/22/12 15:00 06/27/12 2400 80.0 4

0.10 1.00 1

2.77E-15 0.00 1.55E-15 6/25/12 7:00 6/29/12 15:00 07/05/12 2400 80.0 4

0.10 1.00 1

2.77E-15 0.00 1.55E-15 7/2/12 7:00 7/6/12 15:00 07/11/12 2400 80.0 2

0.10 1.00 0

1.05E-15 0.00 1.55E-15 7/9/12 7:00 7/13/12 15:00 07/18/12 2400 80.0 6

0.20 1.00 2

3.82E-15 0.00 2.07E-15 7/16/12 7:00 7/20/12 15:00 07/25/12 2400 80.0 3

0.30 1.00 0

5.93E-16 0.00 2.47E-15 7/23/12 7:00 7/27/12 15:00 08/01/12 2400 80.0 1

0.20 1.00 0

-4.61E-16 0.00 2.07E-15 Counting Instrument:

3030E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Limiting Alpha Isotope of Concern Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Fraction of DAC Limit Alpha Alpha MDA (uCi/cc)

Asbestos Work Area Dirty Asbestos Work Area Dirty Asbestos Work Area Dirty Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Asbestos Work Area 3401 Asbestos Work Area 2590A Counting Instrument:

3030 E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Limiting Alpha Isotope of Concern Type Air Sample Start Date/Time Air Sample End Date/Time Count Date Run Time (min)

Flow Rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Fraction Environ.

Effluent Limit Alpha Alpha MDA (uCi/cc)

ACM containment ACM containment ACM containment ACM containment ACM containment ACM containment ACM containment ACM containment ACM containment Page 5 of 8

UNC New Haven Decommissioning - Breathing Zone Air Sample Results Detector:

6/7/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3434 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occup. DAC U-234 2.00E-11 8/29/11 7:29 8/31/11 15:09 09/06/11 349 4.0 10 0

1.00 3

9.40E-13 0.3 2.55E-13 8/31/11 8:00 8/31/11 15:00 09/06/11 349 4.0 4

0 1.00 1

3.76E-13 0.1 2.55E-13 9/22/11 7:32 9/22/11 15:12 09/27/11 414 4.0 0

0.1 1.00 0

-7.92E-14 0.0 5.83E-13 9/20/11 8:40 9/20/11 15:20 09/27/11 400 4.0 2

0.1 1.00 0

8.20E-14 0.0 6.04E-13 9/21/11 7:40 9/20/11 15:00 09/27/11 440 4.0 0

0.1 1.00 0

-7.45E-14 0.0 5.49E-13 9/23/11 7:40 9/23/11 14:06 09/27/11 386 4.0 0

0.1 1.00 0

-8.50E-14 0.0 6.26E-13 9/26/11 7:40 9/26/11 15:09 09/27/11 419 4.0 2

0.1 1.00 0

7.83E-14 0.0 5.76E-13 9/26/11 7:30 9/26/11 15:10 09/27/11 450 4.0 8

0.1 1.00 2

5.10E-13 0.2 5.37E-13 9/29/11 8:00 9/29/11 14:36 09/30/11 396 4.0 0

0.20 1.00

-1

-1.66E-13

-0.1 7.69E-13 9/30/11 9:40 9/30/11 15:00 09/30/11 326 4.0 0

0.20 1.00

-1

-2.01E-13

-0.1 9.35E-13 10/4/11 7:40 10/4/11 15:30 10/07/11 470 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.48E-13 10/5/11 7:40 10/5/11 15:45 10/07/11 485 4.0 1

0.20 1.00 0

-6.76E-14 0.0 6.28E-13 10/6/11 7:26 10/6/11 9:18 10/13/11 112 4.0 4

0.30 1.00 0

2.93E-13 0.0 3.15E-12 10/10/11 7:45 10/10/11 15:40 10/13/11 435 4.0 3

0.30 1.00 0

0.00E+00 0.0 8.12E-13 10/11/11 8:10 10/11/11 15:00 10/13/11 410 4.0 3

0.30 1.00 0

0.00E+00 0.0 8.61E-13 10/17/11 7:40 10/17/11 16:10 10/18/11 450 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.37E-13 10/24/11 7:20 10/24/11 14:50 10/27/11 450 4.0 1

0.00 1.00 0

7.29E-14 0.0 1.97E-13 10/24/11 7:20 10/24/11 14:50 10/27/11 450 4.0 2

0.00 1.00 1

1.46E-13 0.1 1.97E-13 11/2/11 7:40 11/2/11 15:00 11/07/11 442 4.0 0

0.10 1.00 0

-7.42E-14 0.0 5.46E-13 11/2/11 7:35 11/2/11 15:10 11/07/11 343 4.0 8

0.30 1.00 1

4.78E-13 0.1 1.03E-12 11/7/11 7:30 11/7/11 15:10 11/09/11 341 4.0 6

0.00 1.00 2

5.77E-13 0.2 2.61E-13 11/8/11 7:20 11/8/11 14:38 11/10/11 393 4.0 1

0.00 1.00 0

8.34E-14 0.0 2.26E-13 11/14/11 7:30 11/14/11 15:08 11/22/11 437 4.0 2

0.10 1.00 0

7.50E-14 0.0 5.53E-13 11/15/11 7:30 11/15/11 14:04 11/22/11 373 4.0 1

0.10 1.00 0

0.00E+00 0.0 6.47E-13 11/17/11 7:30 11/17/11 15:10 11/22/11 478 4.0 0

0.10 1.00 0

-6.86E-14 0.0 5.05E-13 11/16/11 7:30 11/16/11 15:10 11/22/11 445 4.0 0

0.10 1.00 0

-7.37E-14 0.0 5.43E-13 11/14/11 7:20 11/14/11 14:38 11/22/11 470 4.0 0

0.10 1.00 0

-6.98E-14 0.0 5.14E-13 11/21/11 7:45 11/21/11 15:26 11/29/11 448 4.0 2

0.00 1.00 1

1.46E-13 0.1 1.98E-13 11/21/11 7:30 11/16/11 15:10 11/29/11 460 4.0 1

0.00 1.00 0

7.13E-14 0.0 1.93E-13 11/22/11 7:40 11/22/11 15:14 11/29/11 466 4.0 5

0.00 1.00 1

3.52E-13 0.1 1.91E-13 11/23/11 7:30 11/23/11 13:20 11/29/11 314 4.0 3

0.00 1.00 1

3.13E-13 0.1 2.83E-13 11/28/11 7:45 11/28/11 15:10 11/29/11 332 4.0 9

0.00 1.00 3

8.89E-13 0.2 2.68E-13 11/29/11 7:30 11/29/11 15:08 11/30/11 220 4.0 4

0.20 1.00 1

2.98E-13 0.1 1.38E-12 11/29/11 7:30 11/29/11 15:08 12/05/11 458 4.0 0

0.20 1.00

-1

-1.43E-13

-0.1 6.65E-13 11/30/11 7:30 11/30/11 15:06 12/05/11 456 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.68E-13 12/2/11 7:30 12/2/11 14:54 12/05/11 444 4.0 0

0.20 1.00

-1

-1.48E-13

-0.1 6.86E-13 12/6/11 7:35 12/6/11 11:53 12/14/11 258 4.0 3

0.30 1.00 0

0.00E+00 0.0 1.37E-12 12/8/11 7:35 12/8/11 15:07 12/14/11 452 4.0 0

0.30 1.00

-1

-2.18E-13

-0.1 7.81E-13 12/9/11 7:30 12/9/11 13:35 12/14/11 365 4.0 2

0.30 1.00 0

-8.98E-14 0.0 9.68E-13 12/12/11 7:30 12/12/11 15:06 12/14/11 456 4.0 2

0.30 1.00 0

-7.19E-14 0.0 7.74E-13 12/13/11 7:30 12/13/11 15:06 12/22/11 456 4.0 1

0.60 1.00

-1

-3.60E-13

-0.1 1.01E-12 12/14/11 7:30 12/14/11 15:06 12/22/11 456 4.0 1

0.60 1.00

-1

-3.60E-13

-0.1 1.01E-12 12/15/11 7:30 12/15/11 15:06 12/22/11 456 4.0 4

0.60 1.00

-1

-1.44E-13

-0.1 1.01E-12 12/16/11 7:30 12/16/11 15:06 12/22/11 456 4.0 1

0.60 1.00

-1

-3.60E-13

-0.1 1.01E-12 12/19/11 7:30 12/19/11 15:06 12/22/11 456 4.0 3

0.60 1.00

-1

-2.16E-13

-0.1 1.01E-12 12/21/11 7:30 12/21/11 15:06 12/22/11 456 4.0 9

0.60 1.00 1

2.16E-13 0.1 1.01E-12 12/23/11 7:30 12/23/11 15:05 01/05/12 455 4.0 2

0.30 1.00 0

-7.21E-14 0.0 7.76E-13 12/22/11 7:30 12/22/11 15:05 01/05/12 455 4.0 4

0.30 1.00 0

7.21E-14 0.0 7.76E-13 12/23/11 7:30 12/23/11 15:05 01/05/12 455 4.0 3

0.30 1.00 0

0.00E+00 0.0 7.76E-13 12/23/11 7:30 12/23/11 15:05 01/05/12 455 4.0 7

0.30 1.00 1

2.88E-13 0.1 7.76E-13 1/3/12 7:30 1/3/12 15:05 01/06/12 455 4.0 0

0.10 1.00 0

-7.21E-14 0.0 5.31E-13 1/4/12 7:30 1/4/12 12:04 01/06/12 274 4.0 0

0.10 1.00 0

-1.20E-13 0.0 8.81E-13 1/5/12 7:30 1/5/12 15:05 01/09/12 450 4.0 0

0.20 1.00

-1

-1.46E-13

-0.1 6.77E-13 1/5/12 8:50 1/5/12 14:05 01/09/12 315 4.0 0

0.20 1.00

-1

-2.08E-13

-0.1 9.67E-13 1/6/12 8:30 1/6/12 15:00 01/09/12 390 4.0 4

0.20 1.00 1

1.68E-13 0.1 7.81E-13 1/9/12 9:30 1/9/12 13:56 01/12/12 266 4.0 6

0.10 1.00 1

6.16E-13 0.1 9.08E-13 1/9/12 7:40 1/9/12 15:10 01/12/12 450 4.0 5

0.10 1.00 1

2.91E-13 0.1 5.37E-13 1/12/12 8:00 1/12/12 1500 01/16/12 420 4.0 2

0.20 1.00 0

0.00E+00 0.0 7.25E-13 1/13/12 0730 1/13/12 1500 01/16/12 450 4.0 1

0.20 1.00 0

-7.29E-14 0.0 6.77E-13 1/11/12 0800 1/11/12 1445 01/16/12 405 4.0 2

0.20 1.00 0

0.00E+00 0.0 7.52E-13 1/12/12 0800 1/12/12 1440 01/16/12 400 4.0 2

0.20 1.00 0

0.00E+00 0.0 7.62E-13 1/13/12 0906 1/13/12 1450 01/16/12 344 4.0 2

0.20 1.00 0

0.00E+00 0.0 8.86E-13 1/10/12 0740 1/10/12 1505 01/16/12 445 4.0 0

0.20 1.00

-1

-1.47E-13

-0.1 6.85E-13 1/11/12 0740 1/11/12 1500 01/16/12 440 4.0 0

0.20 1.00

-1

-1.49E-13

-0.1 6.92E-13 1/16/12 0730 1/16/12 1500 01/23/12 450 4.0 1

0.30 1.00

-1

-1.46E-13

-0.1 7.85E-13 1/17/12 0730 1/17/12 1500 01/23/12 450 4.0 1

0.30 1.00

-1

-1.46E-13

-0.1 7.85E-13 1/18/12 0730 1/18/12 1500 01/23/12 450 4.0 3

0.30 1.00 0

0.00E+00 0.0 7.85E-13 1/19/12 0740 1/19/12 1500 01/23/12 440 4.0 0

0.30 1.00

-1

-2.24E-13

-0.1 8.03E-13 1/20/12 0730 1/20/12 1500 01/23/12 450 4.0 0

0.30 1.00

-1

-2.19E-13

-0.1 7.85E-13 1/17/12 0800 1/17/12 1500 01/23/12 420 4.0 2

0.30 1.00 0

-7.81E-14 0.0 8.41E-13 1/23/12 0800 1/23/12 1420 01/27/12 380 4.0 2

0.20 1.00 0

0.00E+00 0.0 8.02E-13 1/24/12 0740 1/24/12 1500 01/27/12 440 4.0 1

0.20 1.00 0

-7.45E-14 0.0 6.92E-13 S.Gutierrez-Asb.Work J.Castellion-Asb.Work F.Peredes-Asb. Work S.Guiterrez-Asb.Work D.Alvario-Asb.Work Castellon-Asb.Work asb. Work.

S.Devlin A Boginski-Asb. Work Decon Pad Demo-Devlin Decon Pad Demo-Devlin Decon Pad Demo-Devlin A Boginski-Asb. Work E Leon-Asb. Work Leon - South Trench, Asbestos SteveDevlin - South Trench, SteveDevlin - South Trench, Decon Pad J. Cote Alvario-Asb. Work E Leon-Asb. Work asb. Work.

Concrete cutting BZ #612172 Geoprobe sampling #666772 Geoprobe sampling BZ in BZ Devlin BZ Devlin Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work Juan Castellon -asb. work BZ #

Juan Castellon -asb. work BZ #

Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work J Cote - trench excavation Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work Andy Boginski - asb. Work J Cote - trench excavation J Cote - trench excavation A. Craig - trench excavation A. Craig - trench excavation J Cote - trench excavation J. Castillon - asb. work Andy Boginski - asb. Work J Cote - trench excavation J Cote - trench excavation J Cote - trench excavation A Craig - trench excavation J Cote - trench excavation A. Craig - trench excavation J Cote - trench excavation A Craig - trench excavation J Cote - trench excavation J Cote - trench excavation Andy Boginski - asb. Work J Cote - trench excavation J Cote - trench excavation Alpha MDA (uCi/cc)

Andy Boginski - asb. Work Andy Boginski - asb. Work J Cote - trench excavation J Cote - trench excavation Sample Alpha Activity (dpm)

Alpha Count Concen.

(uCi/cc)

Alpha DAC-hours Flow rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction) hank sheet Limiting Alpha Isotope of Concern Person Monitored Air Sample Start Time Period Date/Time Air Sample End Time Period Date/Time Count Date Total BZ Run Time (min)

Counting Instrument:

2360 43-10-1 Cal. Date:

Serial #:

193635 PR202583 Cal. Due Date OK?

Page 6 of 8

UNC New Haven Decommissioning - Breathing Zone Air Sample Results Detector:

6/7/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3434 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occup. DAC U-234 2.00E-11 1/25/12 0730 1/25/12 1500 01/27/12 450 4.0 3

0.20 1.00 0

7.29E-14 0.0 6.77E-13 1/26/12 0730 1/26/12 1500 01/27/12 450 4.0 1

0.20 1.00 0

-7.29E-14 0.0 6.77E-13 1/27/12 0730 1/27/12 1500 01/30/12 450 4.0 1

0.30 1.00

-1

-1.46E-13

-0.1 7.85E-13 1/30/12 0740 1/30/12 1500 02/02/12 440 4.0 0

0.30 1.00

-1

-2.24E-13

-0.1 8.03E-13 1/31/12 0740 1/31/12 1500 02/02/12 440 4.0 2

0.30 1.00 0

-7.45E-14 0.0 8.03E-13 2/1/12 0740 2/1/12 1450 02/02/12 430 4.0 0

0.30 1.00

-1

-2.29E-13

-0.1 8.21E-13 1/30/12 0810 1/30/12 1500 02/02/12 400 4.0 3

0.30 1.00 0

0.00E+00 0.0 8.83E-13 1/31/12 0920 1/31/12 1440 02/02/12 310 4.0 4

0.30 1.00 0

1.06E-13 0.0 1.14E-12 2/3/12 0730 2/3/12 1500 02/06/12 450 4.0 2

0.40 1.00

-1

-1.46E-13

-0.1 8.76E-13 2/6/12 0740 2/7/12 1500 02/07/12 440 4.0 0

0.10 1.00 0

-7.45E-14 0.0 5.49E-13 2/7/12 0740 2/7/12 1505 02/10/12 445 4.0 0

0.10 1.00 0

-7.37E-14 0.0 5.43E-13 2/9/12 0740 2/9/12 1440 02/10/12 420 4.0 2

0.10 1.00 0

7.81E-14 0.0 5.75E-13 2/10/12 0730 2/10/12 1500 02/13/12 450 4.0 3

0.10 1.00 1

1.46E-13 0.1 5.37E-13 2/13/12 0730 2/13/12 1500 02/20/12 450 4.0 1

0.30 1.00

-1

-1.46E-13

-0.1 7.85E-13 2/14/12 0725 2/14/12 1500 02/20/12 455 4.0 2

0.30 1.00 0

-7.21E-14 0.0 7.76E-13 2/15/12 0730 2/15/12 1450 02/20/12 440 4.0 4

0.30 1.00 0

7.45E-14 0.0 8.03E-13 2/16/12 0730 2/16/12 1500 02/20/12 450 4.0 0

0.30 1.00

-1

-2.19E-13

-0.1 7.85E-13 2/17/12 0730 2/17/12 1400 02/20/12 390 4.0 0

0.30 1.00

-1

-2.52E-13

-0.1 9.06E-13 2/8/12 0730 2/8/12 1500 02/20/12 450 4.0 0

0.30 1.00

-1

-2.19E-13

-0.1 7.85E-13 2/14/12 0730 2/14/12 1500 02/20/12 450 4.0 3

0.30 1.00 0

0.00E+00 0.0 7.85E-13 2/20/12 0740 2/20/12 1440 02/24/12 420 4.0 2

0.20 1.00 0

0.00E+00 0.0 7.25E-13 2/21/12 0740 2/21/12 1500 02/24/12 440 4.0 0

0.20 1.00

-1

-1.49E-13

-0.1 6.92E-13 2/22/12 0730 2/22/12 1450 02/24/12 440 4.0 3

0.20 1.00 0

7.45E-14 0.0 6.92E-13 2/23/12 0725 2/23/12 1505 02/24/12 460 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.62E-13 2/24/12 1000 2/24/12 1500 02/27/12 300 4.0 1

0.40 1.00

-1

-3.28E-13

-0.1 1.31E-12 2/27/12 0730 2/27/12 1455 03/02/12 445 4.0 3

0.10 1.00 1

1.47E-13 0.1 5.43E-13 2/28/12 0735 2/28/12 1450 03/02/12 435 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.55E-13 2/29/12 0735 2/29/12 1310 03/02/12 335 4.0 4

0.10 1.00 1

2.94E-13 0.1 7.21E-13 2/28/12 1107 2/28/12 1530 03/02/12 196 4.0 1

0.10 1.00 0

0.00E+00 0.0 1.23E-12 3/1/12 0730 3/1/12 1500 03/05/12 450 4.0 2

0.10 1.00 0

7.29E-14 0.0 5.37E-13 3/2/12 0735 3/2/12 1500 03/05/12 445 4.0 3

0.10 1.00 1

1.47E-13 0.1 5.43E-13 3/5/12 0725 3/5/12 1500 03/13/12 455 4.0 2

0.10 1.00 0

7.21E-14 0.0 5.31E-13 3/6/12 0730 3/6/12 1500 03/13/12 450 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.37E-13 3/7/12 0730 3/7/12 1500 03/13/12 450 4.0 0

0.10 1.00 0

-7.29E-14 0.0 5.37E-13 3/8/12 0730 3/8/12 1500 03/13/12 450 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.37E-13 3/9/12 0725 3/9/12 1340 03/09/12 375 4.0 2

0.10 1.00 0

8.74E-14 0.0 6.44E-13 3/12/12 0730 3/12/12 1450 03/16/12 440 4.0 2

0.30 1.00 0

-7.45E-14 0.0 8.03E-13 3/13/12 0730 3/13/12 1400 03/16/12 390 4.0 3

0.30 1.00 0

0.00E+00 0.0 9.06E-13 3/19/12 0730 3/19/12 1130 03/23/12 240 4.0 2

0.10 1.00 0

1.37E-13 0.0 1.01E-12 3/20/12 0730 3/20/12 1150 03/23/12 260 4.0 3

0.10 1.00 1

2.52E-13 0.1 9.29E-13 3/21/12 0730 3/21/12 1055 03/26/12 205 4.0 1

0.20 1.00 0

-1.60E-13 0.0 1.49E-12 3/22/12 0730 3/22/12 1500 03/26/12 450 4.0 0

0.20 1.00

-1

-1.46E-13

-0.1 6.77E-13 3/23/12 0735 3/23/12 1500 03/26/12 445 4.0 1

0.20 1.00 0

-7.37E-14 0.0 6.85E-13 3/26/12 0730 3/26/12 1450 04/03/12 440 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.49E-13 3/27/12 0730 3/27/12 1446 04/03/12 436 4.0 0

0.10 1.00 0

-7.52E-14 0.0 5.54E-13 3/28/12 0725 3/28/12 1500 04/03/12 455 4.0 2

0.10 1.00 0

7.21E-14 0.0 5.31E-13 3/29/12 0730 3/29/12 1455 04/03/12 445 4.0 1

0.10 1.00 0

0.00E+00 0.0 5.43E-13 4/2/12 0730 4/2/12 1445 04/09/12 435 4.0 2

0.20 1.00 0

0.00E+00 0.0 7.00E-13 4/3/12 0725 4/3/12 1450 04/09/12 440 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.92E-13 4/4/12 0735 4/4/12 1450 04/09/12 445 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.85E-13 4/5/12 0730 4/5/12 1500 04/09/12 450 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.77E-13 4/9/12 0725 4/9/12 1455 04/16/12 450 4.0 0

0.40 1.00

-1

-2.91E-13

-0.1 8.76E-13 4/10/12 0720 4/10/12 1500 04/16/12 460 4.0 1

0.40 1.00

-1

-2.14E-13

-0.1 8.57E-13 4/11/12 0725 4/11/12 1500 04/16/12 455 4.0 0

0.40 1.00

-1

-2.88E-13

-0.1 8.66E-13 4/12/12 0730 4/12/12 1455 04/16/12 445 4.0 5

0.40 1.00 0

7.37E-14 0.0 8.85E-13 4/13/12 0730 4/13/12 1455 04/16/12 445 4.0 4

0.40 1.00 0

0.00E+00 0.0 8.85E-13 4/10/12 0958 4/10/12 1312 04/18/12 194 4.0 3

0.30 1.00 0

0.00E+00 0.0 1.82E-12 4/11/12 10:03 4/11/12 14:40 04/18/12 277 4.0 6

0.3 1.00 1

3.55E-13 0.1 1.27E-12 4/12/12 8:25 4/12/12 13:55 04/18/12 273 4.0 5

0.3 1.00 1

2.40E-13 0.1 1.29E-12 4/16/12 7:25 4/16/12 14:55 04/23/12 450 4.0 0

0.2 1.00

-1

-1.46E-13

-0.1 6.77E-13 4/17/12 7:25 4/17/12 15:00 04/23/12 455 4.0 5

0.2 1.00 1

2.16E-13 0.1 6.70E-13 4/18/12 7:30 4/18/12 15:00 04/23/12 450 4.0 4

0.2 1.00 1

1.46E-13 0.1 6.77E-13 4/19/12 7:30 4/19/12 16:31 04/23/12 541 4.0 3

0.2 1.00 0

6.06E-14 0.0 5.63E-13 4/20/12 7:30 4/20/12 15:45 04/23/12 555 4.0 1

0.2 1.00 0

-5.91E-14 0.0 5.49E-13 4/23/12 7:54 4/23/12 15:02 04/24/12 428 4.0 2

0.2 1.00 0

0.00E+00 0.0 7.12E-13 4/24/12 7:21 4/24/12 15:12 04/25/12 471 4.0 8

0.30 1.00 1

3.48E-13 0.1 7.50E-13 4/25/12 7:15 4/25/12 15:15 04/26/12 480 4.0 4

0.00 1.00 1

2.73E-13 0.1 1.85E-13 4/26/12 7:18 4/26/12 15:01 04/27/12 463 4.0 4

0.10 1.00 1

2.12E-13 0.1 5.21E-13 4/27/12 7:20 4/27/12 15:00 4/302012 460 4.0 0

0.20 1.00

-1

-1.43E-13

-0.1 6.62E-13 4/30/12 7:15 4/30/12 15:11 05/01/12 476 4.0 4

0.20 1.00 1

1.38E-13 0.1 6.40E-13 4/17/12 9:19 4/17/12 13:44 05/01/12 265 4.0 5

0.20 1.00 1

3.71E-13 0.1 1.15E-12 5/1/12 7:30 5/1/12 14:37 05/02/12 427 4.0 1

0.30 1.00

-1

-1.54E-13

-0.1 8.27E-13 5/2/12 7:20 5/2/12 14:25 05/03/12 425 4.0 5

0.10 1.00 1

3.09E-13 0.1 5.68E-13 5/3/12 7:35 5/3/12 14:53 05/04/12 438 4.0 3

0.20 1.00 0

7.49E-14 0.0 6.96E-13 5/4/12 7:32 5/4/12 13:47 05/07/12 375 4.0 2

0.10 1.00 0

8.74E-14 0.0 6.44E-13 Counting Instrument:

2360 43-10-1 Cal. Date:

Serial #:

193635 PR202583 Cal. Due Date OK?

hank sheet Limiting Alpha Isotope of Concern Person Monitored Air Sample Start Time Period Date/Time Air Sample End Time Period Date/Time Count Date Total BZ Run Time (min)

Flow rate (lpm)

Sample Gross Alpha (Counts)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity (dpm)

Castellon -Asb work Castellon -Asb work Castellon -Asb work Andy Baginski-Abs Work Andy Baginski-Abs Work Castellon -Asb work AIG Castellon -Asb work Andy Baginski-Abs Work Andy Baginski-Abs Work Andy Baginski-Abs Work Castellon -Asb work J Cote - asb. Work Steve Devlin-south trench soil Castellon -Asb work Castellon -Asb work Boyinsv. S - Asb work AIG Alvario-Asb. Work Corte-AsbWork Corte-AsbWork Castellon-Asb.Work JCoteSoTrench DwnHole Alpha Count Concen.

(uCi/cc)

Alvario-Asb. Work Cote-AsbWork Boginski-Asb.Work Alvario-Asb. Work Poredes-AsbWork Boginski-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Boginski-Asb.Work Castellon-Asb.Work Boginski-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Boginski-Asb.Work Boginski-Asb.Work Castellon-Asb.Work Boginski-Asb.Work Castellon-Asb.Work Devlin Decon RM Boginski-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Boginski-Asb.Work Boginski-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Castellon-Asb.Work Leon-Asb. Work Boginski-Asb.Work Leon-Asb. Work Devlin-Laydown Area Castellon-Asb.Work Castellon-Asb.Work Alvario-Asb. Work Leon-Asb. Work Alvario-Asb. Work Alvario-Asb. Work Leon-Asb. Work Leon-Asb. Work J.Castellion-Asb.Work J.Castellion-Asb.Work J.Cote Xray RM J.Cote Laydwn J.Castellon-Asb.Work Alvario-Asb. Work J.Castellion-Asb.Work S.Gutierrez-Asb.Work J.Castellion-Asb.Work J.Castellion-Asb.Work Alpha DAC-hours Alpha MDA (uCi/cc)

Page 7 of 8

UNC New Haven Decommissioning - Breathing Zone Air Sample Results Detector:

4/6/2011 Serial #:

OK Radiation Type Counting Efficiency (fraction)

Source Nuclide Source Number Original Source Activity (DPM)

Source Creation Date T1/2 (yr)

Source Decayed Activity Sample Count time (min)

Background

Count time (min)

Alpha 0.3561 Th-230 7102-10 17,400 6/16/2010 7.70E+04 17400 10 10 Isotope 10CFR20 Occup. DAC U-234 2.00E-11 9/1/11 10:00 9/1/11 14:45 09/06/11 285 4.0 1

0.1 1.00 0

0.00E+00 0.0 8.47E-13 8/23/11 9:57 8/26/11 15:00 09/06/11 1500 4.0 2

0.1 1.00 0

2.11E-14 0.0 1.61E-13 9/6/11 7:31 9/6/11 15:10 09/12/11 348 4.0 2

0 1.00 1

1.82E-13 0.1 2.55E-13 9/7/11 7:35 9/9/11 15:15 09/12/11 1027 4.0 4

0 1.00 1

1.23E-13 0.1 8.65E-14 9/12/11 7:30 9/12/11 15:16 09/13/11 352 4.0 6

0.20 1.00 1

3.59E-13 0.1 8.65E-13 9/13/11 8:35 9/13/11 15:15 09/15/11 254 4.0 4

0 1.00 1

4.98E-13 0.1 3.50E-13 9/14/11 8:35 9/14/11 15:15 09/15/11 358 4.0 11 0

1.00 3

9.72E-13 0.3 2.48E-13 9/14/11 9:38 9/14/11 15:15 09/15/11 295 4.0 1

0 1.00 0

1.07E-13 0.0 3.01E-13 9/15/11 7:35 9/15/11 15:12 09/21/11 457 4.0 3

0.1 1.00 1

1.38E-13 0.1 5.28E-13 9/16/11 7:34 9/16/11 15:06 09/21/11 452 4.0 1

0.1 1.00 0

0.00E+00 0.0 5.34E-13 9/16/11 7:44 9/16/11 15:20 09/21/11 456 4.0 2

0.1 1.00 0

6.94E-14 0.0 5.29E-13 9/19/11 7:53 9/19/11 14:48 09/21/11 415 4.0 1

0.1 1.00 0

0.00E+00 0.0 5.82E-13 10/3/11 9:53 10/3/11 16:00 10/05/11 367 4.0 5

0.1 1.00 1

3.45E-13 0.1 6.58E-13 10/26/11 8:00 10/26/11 15:03 11/02/11 335 4.0 1

0.30 1.00

-1

-1.89E-13

-0.1 1.05E-12 10/27/11 7:45 10/27/11 15:10 11/02/11 330 4.0 0

0.30 1.00

-1

-2.87E-13

-0.1 1.07E-12 10/28/11 7:45 10/28/11 15:04 11/02/11 396 4.0 2

0.30 1.00 0

-7.99E-14 0.0 8.92E-13 10/28/11 7:40 10/28/11 15:05 11/02/11 332 4.0 1

0.30 1.00

-1

-1.91E-13

-0.1 1.06E-12 11/1/11 8:10 11/1/11 13:28 11/02/11 262 4.0 3

0.30 1.00 0

0.00E+00 0.0 1.35E-12 11/1/11 7:30 11/1/11 15:10 11/02/11 345 4.0 7

0.30 1.00 1

3.67E-13 0.1 1.02E-12 11/2/11 7:40 11/2/11 15:15 11/07/11 346 4.0 14 0.10 1.00 4

1.19E-12 0.3 6.98E-13 11/3/11 7:40 11/3/11 15:10 11/07/11 334 4.0 5

0.10 1.00 1

3.79E-13 0.1 7.23E-13 11/4/11 10:25 11/4/11 11:51 11/07/11 86 4.0 1

0.10 1.00 0

0.00E+00 0.0 2.81E-12 11/4/11 10:15 11/4/11 15:05 11/07/11 217 4.0 4

0.10 1.00 1

4.37E-13 0.1 1.11E-12 11/4/11 10:16 11/4/11 15:10 11/07/11 226 4.0 5

0.10 1.00 1

5.60E-13 0.1 1.07E-12 11/8/11 7:20 11/8/11 15:10 11/10/11 355 4.0 6

0.10 1.00 1

4.45E-13 0.1 6.80E-13 11/9/11 7:30 11/9/11 15:10 11/14/11 436 4.0 2

0.20 1.00 0

0.00E+00 0.0 6.99E-13 11/9/11 0:00 11/9/11 0:00 11/14/11 375 4.0 1

0.20 1.00 0

-8.43E-14 0.0 8.12E-13 11/10/11 7:30 11/10/11 15:10 11/15/11 438 4.0 8

0.20 1.00 2

4.33E-13 0.2 6.96E-13 11/11/11 7:30 11/11/11 15:10 11/15/11 343 4.0 2

0.20 1.00 0

0.00E+00 0.0 8.88E-13 12/1/11 7:30 12/1/11 15:06 12/05/11 314 4.0 3

0.30 1.00 0

0.00E+00 0.0 1.12E-12 12/5/11 7:30 12/5/11 15:06 12/06/11 314 4.0 3

0.30 1.00 0

0.00E+00 0.0 1.12E-12 Andy Boginski - asb. Work J. Castillon - asb. work A. Boginski - asb. Work J Cote - trench excavation A. Boginski - asb. Work A. Boginski - asb. Work Andy Boginski - asb. Work J. Castillon - asb. work A. Boginski - asb. Work J. Castillon - asb. work J Cote - trench excavation J. Castillon - asb. work A. Boginski - asb. Work J Cote - trench excavation A. Craig - trench excavation J. Castillon - asb. work J Cote - trench excavation J. Castillon - asb. work J Cote - trench excavation A. Boginski - asb. work J Cote - trench excavation J. Castillon - asb. work A. Boginski - asb. Work J Cote - trench excavation J. Castillon - asb. work Excavation - Argyle St Sewer Miller Galindo - asb. work Juan Castellon - asb. work A. Boginzki - asb. Work Juan Castellon - asb. work Juan Castellon - asb. work Alpha Count Concen.

Alpha DAC-hours Alpha MDA (uCi/cc)

Alpha Bkg (cpm)

Filter Efficiency (fraction)

Sample Alpha Activity hank sheet Limiting Alpha Isotope of Concern Person Monitored Air Sample Start Time Period Air Sample End Time Period Count Date Total BZ Run Time (min)

Flow rate (lpm)

Sample Gross Alpha Counting Instrument:

3030E 43-10-1 Cal. Date:

Serial #:

217611 PR232046 Cal. Due Date OK?

Page 8 of 8