US 115NW Nonwoven Geotextile US 115NW is a nonwoven needlepunched geotextile made of 100% polypropylene staple filaments. Primarily used in drainage applications, this product prevents soil fines from entering the system extending drain life and performance. US 115NW can also be used in lightweight separation applications. US 115NW meets the following M.A.R.V. values except where noted:
PROPERTY TEST METHOD ENGLISH METRIC Weight - Typical ASTM D-5261 4.0 oz/sy 136 g/sm Tensile Strength ASTM D-4632 115 lbs 512 N Elongation @ Break ASTM D-4632 50%
50%
Mullen Burst ASTM D-3786 210 psi 1,448 kPa Puncture Strength ASTM D-4833 65 lbs 289 N CBR Puncture ASTM D-6241 300 lbs 1,335 N Trapezoidal Tear ASTM D-4533 50 lbs 222 N Apparent Opening Size ASTM D-4751 70 US Sieve 0.212 mm Permittivity ASTM D-4491 2.00 Sec-1 2.00 Sec-1 Water Flow Rate ASTM D-4491 140 g/min/sf 5,689 l/min/sm UV Resistance @ 500 Hours ASTM D-4355 70%
70%
ROLL SIZE AREA WEIGHT 12.5' x 360' 500 sys 146 lbs 15' x 360' 600 sys 172 lbs The above information is to the best of our knowledge accurate, but it is not intended to be considered a guarantee. Any implied warranty for a particular use or purpose is excluded. If the product does not meet the above properties, and notice is given to US Fabrics, Inc., the product will be replaced or refunded (1/2012).
US Fabrics, Inc. l 3904 Virginia Avenue l Cincinnati, OH 45227 (USA) l Phone: 800-518-2290 l Fax: (513) 271-4420