20190415_UNC New Haven Racr, Appendix a Fssr Attachment 7 Structure Survey Unit Removable Measurement Data
ML19163A370
Person / Time
Site: 07000371
Issue date: 11/30/2018
From:
Cabrera Services
To:
NRC Region 1
Shared Package
ML051740240, ML19095A008 List: ... further results
References
Download: ML19163A370 (58)


Text

Survey # of Unit Msmts 1-F 22 11 6

10 3

0

-38 42 55 10 28 987 964 497 179 1-W1 22 6

12 4

16 0

0 25 51 7

23 991 970 725 214 1-W2 22 3

-17 2

-23

-1

-64 13 47 4

33 994 957 1,168 152 2-F 23 95 26 98 22 5

38 238 98 52 36 817 937 36 104 2-W 22 15 14 8

13 1

36 98 54 25 27 986 974 457 251 3-F 22 13

-1 14 3

0

-61 47 47 13 29 983 962 375 170 3-W1 22 8

9 3

19 0

-52 106 60 22 34 971 956 223 148 3-W2 22 2

12 0

14 0

-35 14 43 3

21 996 973 1,508 241 3-W3 20 1

-2 0

-1 0

-38 8

29 2

17 997 978 2,157 298 4-F1 22 0

6

-1 15

-1

-48 4

33 2

23 998 971 2,674 220 4-F2 17

-1

-11

-1

-15

-1

-41 1

33 1

21 998 973 4,074 240 4-W1 22 0

1 0

-3 0

-39 5

54 2

25 998 968 3,235 203 4-W2 22 1

0 0

0 0

-46 5

46 2

23 998 970 2,654 219 4-W3 22 1

-12 0

-7 0

-54 5

32 2

27 998 965 2,648 184 5-F 22 2

-6 0

-10 0

-40 8

53 2

27 997 965 2,101 186 5-W 22 0

8

-1 7

-1

-38 5

51 2

20 998 974 3,235 251 6-F1 22 2

4 3

4 0

-36 8

49 2

24 997 969 2,016 211 6-F2 22 2

3 0

-3 0

-36 14 56 4

24 995 969 1,314 210 6-W1 22 1

11

-1 10

-1

-42 7

74 3

22 996 972 1,770 231 6-W2 22 1

20

-1 18

-1

-35 7

77 2

29 997 962 2,088 170 6-FW1 22 1

1 0

0 0

-30 5

59 2

24 998 968 2,673 205 6-FW2 22 1

12

-1 7

-1

-19 5

52 2

21 997 973 2,411 240 AP 28 1

5

-1 6

-1

-32 13 58 3

24 996 969 1,643 211 DP 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DP Rm 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SmTr 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A XY 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A HR 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Table 6-6. Structure Survey Unit Removable Survey Systematic Measurement Summary Relative Shift (unitless)

Standard Deviation Mean Median Minimum Maximum disintegrations per minute per 100 square centimeters (dpm/100 cm2)

Power < 1

Survey # of Unit Msmts 1-F 5

6 13 5

3 0

-5 11 66 5

30 994 961 1,021 166 1-W1 6

1 3

1 5

0

-23 3

33 2

22 998 971 3,250 225 1-W2 5

1

-18 0

-23 0

-42 3

7 1

20 998 974 3,982 248 2-F 26 163 44 171 45 59

-7 334 111 59 31 923 960 81 161 2-W 7

15 17 8

20 5

-21 56 50 18 23 976 970 276 216 3-F 2

10 21 10 21 3

17 17 25 10 5

987 993 503 948 3-W1 4

6 19 5

21 0

-3 14 38 7

18 990 976 676 270 3-W2 3

3 26 0

36 0

-20 8

62 5

42 994 946 1,028 119 3-W3 2

3 8

3 8

3

-18 3

34 0

37 1,000 952 INF 136 4-F1 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4-F2 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 4-W1 3

0

-18 0

-1 0

-60 0

7 0

37 1,000 952 INF 136 4-W2 3

1

-27 0

-23 0

-42 3

-16 2

13 998 983 3,084 375 4-W3 14 1

-2 0

-2 0

-35 5

28 2

20 998 974 2,913 249 5-F 8

0 3

-1

-6

-1

-19 2

40 1

24 998 969 3,441 212 5-W 12 0

-8 0

-9 0

-48 0

27 0

23 1,000 970 INF 220 6-F1 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6-F2 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6-W1 4

0 16

-1 19

-1

-24 2

47 1

30 998 961 3,566 168 6-W2 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6-FW1 10 1

11 1

5 0

-19 5

44 2

22 997 972 2,546 228 6-FW2 8

-1 10

-1 13

-1

-26

-1 48 0

24 1,000 969 INF 210 AP 0

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A DP 26 2

5 2

-2

-1

-47 11 87 3

33 995 958 1,442 153 DP Rm 15 23 16 13 6

-1

-27 81 62 26 29 966 963 190 175 SmTr 34 4

11 2

14

-1

-39 16 76 5

28 993 964 984 180 XY 12 21

-5 8

-2

-1

-46 92 28 29 21 962 973 171 242 HR 13 0

-4

-1

-6

-1

-38 7

55 2

27 997 965 2,031 189 Relative Shift (unitless)

Power < 1 Table 6-7. Structure Survey Unit Removable Survey Systematic Measurement Summary disintegrations per minute per 100 square centimeters (dpm/100 cm2)

Standard Deviation Mean Median Minimum Maximum

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 F #1 S

4 0.0 4.0 11.2 NO South Trench Sec 1 F #2 S

7 0.0 7.0 19.7 NO South Trench Sec 1 F #3 S

0 0.0 0.0 0.0 NO South Trench Sec 1 F #4 S

3 0.0 3.0 8.4 NO South Trench Sec 1 F #5 S

5 0.0 5.0 14.0 NO South Trench Sec 1 F #6 S

8 0.0 8.0 22.5 NO South Trench Sec 1 F #7 S

15 0.0 15.0 42.1 NO South Trench Sec 1 F #8 S

6 0.0 6.0 16.8 NO South Trench Sec 1 F #9 S

5 0.0 5.0 14.0 NO South Trench Sec 1 F #10 S

8 0.0 8.0 22.5 NO South Trench Sec 1 F #11 S

4 0.0 4.0 11.2 NO South Trench Sec 1 F #12 S

2 0.0 2.0 5.6 NO South Trench Sec 1 F #13 S

4 0.0 4.0 11.2 NO South Trench Sec 1 F #14 S

5 0.0 5.0 14.0 NO South Trench Sec 1 F #15 S

1 0.0 1.0 2.8 NO South Trench Sec 1 F #16 S

3 0.0 3.0 8.4 NO South Trench Sec 1 F #17 S

0 0.0 0.0 0.0 NO South Trench Sec 1 F #18 S

2 0.0 2.0 5.6 NO South Trench Sec 1 F #19 S

0 0.0 0.0 0.0 NO South Trench Sec 1 F #20 S

0 0.0 0.0 0.0 NO South Trench Sec 1 F #21 S

0 0.0 0.0 0.0 NO South Trench Sec 1 F #22 S

3 0.0 3.0 8.4 NO Mean 10.8 Median 9.8 Minimum 0.0 Maximum 42.1 Std Dev (1s) 10.0 South Trench Sec 1 F #Y-11 B

4 0.1 3.9 11.0 NO South Trench Sec 1 F #Y-15 B

4 0.1 3.9 11.0 NO South Trench Sec 1 F #X-15 B

2 0.1 1.9 5.3 NO South Trench Sec 1 F #K3 B

0 0.0 0.0 0.0 NO South Trench Sec 1 F #L3 B

1 0.0 1.0 2.8 NO Mean 6.0 Median 5.3 Minimum 0.0 Maximum 11.0 Std Dev (1s)

4.9 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 F #1 S

54 50.2 3.8 14.1 NO South Trench Sec 1 F #2 S

56 50.2 5.8 21.5 NO South Trench Sec 1 F #3 S

40 50.2

-10.2

-37.9 NO South Trench Sec 1 F #4 S

62 50.2 11.8 43.8 NO South Trench Sec 1 F #5 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 F #6 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 F #7 S

42 50.2

-8.2

-30.5 NO South Trench Sec 1 F #8 S

51 50.2 0.8 3.0 NO South Trench Sec 1 F #9 S

42 50.2

-8.2

-30.5 NO South Trench Sec 1 F #10 S

61 50.2 10.8 40.1 NO South Trench Sec 1 F #11 S

49 50.2

-1.2

-4.5 NO South Trench Sec 1 F #12 S

56 50.2 5.8 21.5 NO South Trench Sec 1 F #13 S

47 50.2

-3.2

-11.9 NO South Trench Sec 1 F #14 S

57 50.2 6.8 25.3 NO South Trench Sec 1 F #15 S

44 50.2

-6.2

-23.0 NO South Trench Sec 1 F #16 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 F #17 S

63 50.2 12.8 47.6 NO South Trench Sec 1 F #18 S

53 50.2 2.8 10.4 NO South Trench Sec 1 F #19 S

50 50.2

-0.2

-0.7 NO South Trench Sec 1 F #20 S

60 50.2 9.8 36.4 NO South Trench Sec 1 F #21 S

51 50.2 0.8 3.0 NO South Trench Sec 1 F #22 S

65 50.2 14.8 55.0 NO Mean 5.7 Median 3.0 Minimum

-37.9 Maximum 55.0 Std Dev (1s) 28.0 South Trench Sec 1 F #Y-11 B

47 48.4

-1.4

-5.2 NO South Trench Sec 1 F #Y-15 B

50 48.4 1.6 5.9 NO South Trench Sec 1 F #X-15 B

47 48.4

-1.4

-5.2 NO South Trench Sec 1 F #K3 B

68 50.2 17.8 66.1 NO South Trench Sec 1 F #L3 B

51 50.2 0.8 3.0 NO Mean 12.9 Median 3.0 Minimum

-5.2 Maximum 66.1 Std Dev (1s) 30.2 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 W-1 #1 S

5 0.0 5.0 14.0 NO South Trench Sec 1 W-1 #2 S

5 0.0 5.0 14.0 NO South Trench Sec 1 W-1 #3 S

2 0.0 2.0 5.6 NO South Trench Sec 1 W-1 #4 S

4 0.0 4.0 11.2 NO South Trench Sec 1 W-1 #5 S

4 0.0 4.0 11.2 NO South Trench Sec 1 W-1 #6 S

2 0.0 2.0 5.6 NO South Trench Sec 1 W-1 #7 S

6 0.0 6.0 16.8 NO South Trench Sec 1 W-1 #8 S

2 0.0 2.0 5.6 NO South Trench Sec 1 W-1 #9 S

3 0.0 3.0 8.4 NO South Trench Sec 1 W-1 #10 S

4 0.0 4.0 11.2 NO South Trench Sec 1 W-1 #11 S

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #12 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #13 S

9 0.0 9.0 25.3 NO South Trench Sec 1 W-1 #14 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #15 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #16 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #17 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #18 S

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #19 S

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #20 S

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #21 S

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #22 S

0 0.0 0.0 0.0 NO Mean 6.4 Median 4.2 Minimum 0.0 Maximum 25.3 Std Dev (1s) 6.9 South Trench Sec 1 W-1 #B5 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #C5 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #D6 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-1 #K6 B

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #L6 B

1 0.0 1.0 2.8 NO South Trench Sec 1 W-1 #N6 B

1 0.0 1.0 2.8 NO Mean 1.4 Median 1.4 Minimum 0.0 Maximum 2.8 Std Dev (1s)

1.5 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Wall Survey Unit 1 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 W-1 #1 S

57 50.2 6.8 25.3 NO South Trench Sec 1 W-1 #2 S

56 50.2 5.8 21.5 NO South Trench Sec 1 W-1 #3 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 W-1 #4 S

55 50.2 4.8 17.8 NO South Trench Sec 1 W-1 #5 S

54 50.2 3.8 14.1 NO South Trench Sec 1 W-1 #6 S

64 50.2 13.8 51.3 NO South Trench Sec 1 W-1 #7 S

55 50.2 4.8 17.8 NO South Trench Sec 1 W-1 #8 S

47 50.2

-3.2

-11.9 NO South Trench Sec 1 W-1 #9 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 W-1 #10 S

54 50.2 3.8 14.1 NO South Trench Sec 1 W-1 #11 S

48 50.2

-2.2

-8.2 NO South Trench Sec 1 W-1 #12 S

55 50.2 4.8 17.8 NO South Trench Sec 1 W-1 #13 S

57 50.2 6.8 25.3 NO South Trench Sec 1 W-1 #14 S

62 50.2 11.8 43.8 NO South Trench Sec 1 W-1 #15 S

61 50.2 10.8 40.1 NO South Trench Sec 1 W-1 #16 S

57 50.2 6.8 25.3 NO South Trench Sec 1 W-1 #17 S

53 50.2 2.8 10.4 NO South Trench Sec 1 W-1 #18 S

49 50.2

-1.2

-4.5 NO South Trench Sec 1 W-1 #19 S

63 50.2 12.8 47.6 NO South Trench Sec 1 W-1 #20 S

42 50.2

-8.2

-30.5 NO South Trench Sec 1 W-1 #21 S

45 50.2

-5.2

-19.3 NO South Trench Sec 1 W-1 #22 S

52 50.2 1.8 6.7 NO Mean 12.1 Median 16.0 Minimum

-30.5 Maximum 51.3 Std Dev (1s) 23.3 South Trench Sec 1 W-1 #B5 B

45 50.2

-5.2

-19.3 NO South Trench Sec 1 W-1 #C5 B

59 50.2 8.8 32.7 NO South Trench Sec 1 W-1 #D6 B

44 50.2

-6.2

-23.0 NO South Trench Sec 1 W-1 #K6 B

54 50.2 3.8 14.1 NO South Trench Sec 1 W-1 #L6 B

55 50.2 4.8 17.8 NO South Trench Sec 1 W-1 #N6 B

49 50.2

-1.2

-4.5 NO Mean 3.0 Median 4.8 Minimum

-23.0 Maximum 32.7 Std Dev (1s) 22.2 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Wall Survey Unit 1 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 W-2 #1 S

4 0.3 3.7 10.4 NO South Trench Sec 1 W-2 #2 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #3 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #4 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #5 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #6 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #7 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #8 S

2 0.3 1.7 4.8 NO South Trench Sec 1 W-2 #9 S

1 0.3 0.7 2.0 NO South Trench Sec 1 W-2 #10 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #11 S

2 0.3 1.7 4.8 NO South Trench Sec 1 W-2 #12 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #13 S

1 0.3 0.7 2.0 NO South Trench Sec 1 W-2 #14 S

5 0.3 4.7 13.2 NO South Trench Sec 1 W-2 #15 S

1 0.3 0.7 2.0 NO South Trench Sec 1 W-2 #16 S

2 0.3 1.7 4.8 NO South Trench Sec 1 W-2 #17 S

4 0.3 3.7 10.4 NO South Trench Sec 1 W-2 #18 S

1 0.3 0.7 2.0 NO South Trench Sec 1 W-2 #19 S

0 0.3

-0.3

-0.8 NO South Trench Sec 1 W-2 #20 S

2 0.3 1.7 4.8 NO South Trench Sec 1 W-2 #21 S

1 0.3 0.7 2.0 NO South Trench Sec 1 W-2 #22 S

3 0.3 2.7 7.6 NO Mean 2.9 Median 2.0 Minimum

-0.8 Maximum 13.2 Std Dev (1s) 4.3 South Trench Sec 1 W-2 #F2 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-2 #J2 B

1 0.0 1.0 2.8 NO South Trench Sec 1 W-2 #N2 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-2 #T2 B

0 0.0 0.0 0.0 NO South Trench Sec 1 W-2 #X2 B

0 0.0 0.0 0.0 NO Mean 0.6 Median 0.0 Minimum 0.0 Maximum 2.8 Std Dev (1s)

1.3 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Wall Survey Unit 2 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw South Trench Sec 1 W-2 #1 S

51 49.3 1.7 6.3 NO South Trench Sec 1 W-2 #2 S

49 49.3

-0.3

-1.1 NO South Trench Sec 1 W-2 #3 S

37 49.3

-12.3

-45.7 NO South Trench Sec 1 W-2 #4 S

52 49.3 2.7 10.0 NO South Trench Sec 1 W-2 #5 S

39 49.3

-10.3

-38.3 NO South Trench Sec 1 W-2 #6 S

49 49.3

-0.3

-1.1 NO South Trench Sec 1 W-2 #7 S

33 49.3

-16.3

-60.6 NO South Trench Sec 1 W-2 #8 S

39 49.3

-10.3

-38.3 NO South Trench Sec 1 W-2 #9 S

62 49.3 12.7 47.2 NO South Trench Sec 1 W-2 #10 S

46 49.3

-3.3

-12.3 NO South Trench Sec 1 W-2 #11 S

54 49.3 4.7 17.5 NO South Trench Sec 1 W-2 #12 S

39 49.3

-10.3

-38.3 NO South Trench Sec 1 W-2 #13 S

57 49.3 7.7 28.6 NO South Trench Sec 1 W-2 #14 S

39 49.3

-10.3

-38.3 NO South Trench Sec 1 W-2 #15 S

49 49.3

-0.3

-1.1 NO South Trench Sec 1 W-2 #16 S

32 49.3

-17.3

-64.3 NO South Trench Sec 1 W-2 #17 S

40 49.3

-9.3

-34.6 NO South Trench Sec 1 W-2 #18 S

52 49.3 2.7 10.0 NO South Trench Sec 1 W-2 #19 S

58 49.3 8.7 32.3 NO South Trench Sec 1 W-2 #20 S

33 49.3

-16.3

-60.6 NO South Trench Sec 1 W-2 #21 S

37 49.3

-12.3

-45.7 NO South Trench Sec 1 W-2 #22 S

39 49.3

-10.3

-38.3 NO Mean

-16.7 Median

-23.4 Minimum

-64.3 Maximum 47.2 Std Dev (1s) 33.0 South Trench Sec 1 W-2 #F2 B

52 50.2 1.8 6.7 NO South Trench Sec 1 W-2 #J2 B

44 50.2

-6.2

-23.0 NO South Trench Sec 1 W-2 #N2 B

39 50.2

-11.2

-41.6 NO South Trench Sec 1 W-2 #T2 B

42 50.2

-8.2

-30.5 NO South Trench Sec 1 W-2 #X2 B

50 50.2

-0.2

-0.7 NO Mean

-17.8 Median

-23.0 Minimum

-41.6 Maximum 6.7 Std Dev (1s) 20.3 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 1 - Wall Survey Unit 2 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw S Trench, Sec 2F, Syst #1 S

33 0.2 32.8 92.1 NO S Trench, Sec 2F, Syst #2 S

36 0.2 35.8 100.5 NO S Trench, Sec 2F, Syst #3 S

26 0.2 25.8 72.4 NO S Trench, Sec 2F, Syst #4 S

35 0.2 34.8 97.7 NO S Trench, Sec 2F, Syst #5 S

31 0.2 30.8 86.5 NO S Trench, Sec 2F, Syst #6 S

36 0.2 35.8 100.5 NO S Trench, Sec 2F, Syst #7 S

44 0.4 43.6 122.4 NO S Trench, Sec 2F, Syst #8 S

85 0.4 84.6 237.5 NO S Trench, Sec 2F, Syst #9 S

49 0.4 48.6 136.5 NO S Trench, Sec 2F, Syst #10 S

42 0.4 41.6 116.8 NO S Trench, Sec 2F, Syst #11 S

47 0.4 46.6 130.8 NO S Trench, Sec 2F, Syst #12 S

63 0.4 62.6 175.8 NO S Trench, Sec 2F, Syst #13 S

47 0.4 46.6 130.8 NO S Trench, Sec 2F, Syst #14 S

39 0.4 38.6 108.4 NO S Trench, Sec 2F, Syst #15 S

22 0.4 21.6 60.6 NO S Trench, Sec 2F, Syst #16 S

28 0.4 27.6 77.5 NO S Trench, Sec 2F, Syst #17 S

21 0.4 20.6 57.8 NO S Trench, Sec 2F, Syst #18 S

46 0.3 45.7 128.3 NO S Trench, Sec 2F, Syst #19 S

28 0.3 27.7 77.8 NO S Trench, Sec 2F, Syst #20 S

9 0.3 8.7 24.4 NO S Trench, Sec 2F, Syst #21 S

10 0.3 9.7 27.2 NO S Trench, Sec 2F, Syst #22 S

9 0.3 8.7 24.4 NO S Trench, Sec 2F, Syst #23 S

2 0.3 1.7 4.8 NO Mean 95.3 Median 97.7 Minimum 4.8 Maximum 237.5 Std Dev (1s) 52.3 STrench, Section 2F, Grid 15A B

50 0.0 50.0 140.4 NO STrench, Section 2F, Grid 15B B

61 0.0 61.0 171.3 NO STrench, Section 2F, Grid 16A B

47 0.0 47.0 132.0 NO STrench, Section 2F, Grid 16B B

61 0.0 61.0 171.3 NO STrench, Section 2F, Grid 17A B

72 0.0 72.0 202.2 NO STrench, Section 2F, Grid 17B B

62 0.0 62.0 174.1 NO STrench, Section 2F, Grid 18A B

75 0.0 75.0 210.6 NO STrench, Section 2F, Grid 18B B

64 0.0 64.0 179.7 NO STrench, Section 2F, Grid 18C B

119 0.0 119.0 334.1 NO STrench, Section 2F, Grid 19A B

34 0.0 34.0 95.5 NO STrench, Section 2F, Grid 19B B

57 0.0 57.0 160.0 NO STrench, Section 2F, Grid 20 B

31 0.0 31.0 87.0 NO STrench, Section 2F, Grid 21A B

43 0.0 43.0 120.7 NO STrench, Section 2F, Grid 21B B

61 0.0 61.0 171.3 NO STrench, Section 2F, Grid 22 B

21 0.0 21.0 59.0 NO STrench, Section 2F, Grid 23A B

60 0.0 60.0 168.5 NO STrench, Section 2F, Grid 23B B

71 0.0 71.0 199.4 NO STrench, Section 2F, Grid 24 B

88 0.0 88.0 247.1 NO STrench, Section 2F, Grid 25 B

61 0.0 61.0 171.3 NO S Trench, Sec 2F, Grid 1 B

73 0.4 72.6 203.9 NO S Trench, Sec 2F, Grid 2 B

52 0.4 51.6 144.9 NO S Trench, Sec 2F, Grid 3 B

37 0.4 36.6 102.8 NO S Trench, Sec 2F, Grid 4 B

24 0.4 23.6 66.3 NO S Trench, Sec 2F, Grid 5 B

75 0.4 74.6 209.5 NO S Trench, Sec 2F, Grid 7 B

74 0.4 73.6 206.7 NO S Trench, Sec 2F, Grid 8 B

40 0.4 39.6 111.2 NO Mean 163.1 Median 171.3 Minimum 59.0 Maximum 334.1 Std Dev (1s) 59.4 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 2 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw S Trench, Sec 2F, Syst #1 S

67 47.6 19.4 72.1 NO S Trench, Sec 2F, Syst #2 S

57 47.6 9.4 34.9 NO S Trench, Sec 2F, Syst #3 S

47 47.6

-0.6

-2.2 NO S Trench, Sec 2F, Syst #4 S

46 47.6

-1.6

-5.9 NO S Trench, Sec 2F, Syst #5 S

74 47.6 26.4 98.1 NO S Trench, Sec 2F, Syst #6 S

53 47.6 5.4 20.1 NO S Trench, Sec 2F, Syst #7 S

50 47.1 2.9 10.8 NO S Trench, Sec 2F, Syst #8 S

66 47.1 18.9 70.2 NO S Trench, Sec 2F, Syst #9 S

58 47.1 10.9 40.5 NO S Trench, Sec 2F, Syst #10 S

50 47.1 2.9 10.8 NO S Trench, Sec 2F, Syst #11 S

54 47.1 6.9 25.6 NO S Trench, Sec 2F, Syst #12 S

61 47.1 13.9 51.6 NO S Trench, Sec 2F, Syst #13 S

64 47.1 16.9 62.8 NO S Trench, Sec 2F, Syst #14 S

53 47.1 5.9 21.9 NO S Trench, Sec 2F, Syst #15 S

65 47.1 17.9 66.5 NO S Trench, Sec 2F, Syst #16 S

37 47.1

-10.1

-37.5 NO S Trench, Sec 2F, Syst #17 S

56 47.1 8.9 33.1 NO S Trench, Sec 2F, Syst #18 S

64 48.9 15.1 56.1 NO S Trench, Sec 2F, Syst #19 S

45 48.9

-3.9

-14.5 NO S Trench, Sec 2F, Syst #20 S

50 48.9 1.1 4.1 NO S Trench, Sec 2F, Syst #21 S

47 48.9

-1.9

-7.1 NO S Trench, Sec 2F, Syst #22 S

39 48.9

-9.9

-36.8 NO S Trench, Sec 2F, Syst #23 S

53 48.9 4.1 15.2 NO Mean 25.7 Median 21.9 Minimum

-37.5 Maximum 98.1 Std Dev (1s) 35.6 STrench, Section 2F, Grid 15A B

62 49.0 13.0 48.3 NO STrench, Section 2F, Grid 15B B

79 49.0 30.0 111.5 NO STrench, Section 2F, Grid 16A B

75 49.0 26.0 96.6 NO STrench, Section 2F, Grid 16B B

52 49.0 3.0 11.1 NO STrench, Section 2F, Grid 17A B

47 49.0

-2.0

-7.4 NO STrench, Section 2F, Grid 17B B

63 49.0 14.0 52.0 NO STrench, Section 2F, Grid 18A B

61 49.0 12.0 44.6 NO STrench, Section 2F, Grid 18B B

70 49.0 21.0 78.0 NO STrench, Section 2F, Grid 18C B

74 49.0 25.0 92.9 NO STrench, Section 2F, Grid 19A B

54 49.0 5.0 18.6 NO STrench, Section 2F, Grid 19B B

63 49.0 14.0 52.0 NO STrench, Section 2F, Grid 20 B

57 49.0 8.0 29.7 NO STrench, Section 2F, Grid 21A B

55 49.0 6.0 22.3 NO STrench, Section 2F, Grid 21B B

59 49.0 10.0 37.2 NO STrench, Section 2F, Grid 22 B

59 49.0 10.0 37.2 NO STrench, Section 2F, Grid 23A B

47 49.0

-2.0

-7.4 NO STrench, Section 2F, Grid 23B B

61 49.0 12.0 44.6 NO STrench, Section 2F, Grid 24 B

63 49.0 14.0 52.0 NO STrench, Section 2F, Grid 25 B

63 49.0 14.0 52.0 NO S Trench, Sec 2F, Grid 1 B

66 47.1 18.9 70.2 NO S Trench, Sec 2F, Grid 2 B

51 47.1 3.9 14.5 NO S Trench, Sec 2F, Grid 3 B

49 47.1 1.9 7.1 NO S Trench, Sec 2F, Grid 4 B

52 47.1 4.9 18.2 NO S Trench, Sec 2F, Grid 5 B

63 47.1 15.9 59.1 NO S Trench, Sec 2F, Grid 7 B

67 47.1 19.9 73.9 NO S Trench, Sec 2F, Grid 8 B

56 47.1 8.9 33.1 NO Mean 43.9 Median 44.6 Minimum

-7.4 Maximum 111.5 Std Dev (1s) 30.8 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 2 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw S Trench, Sec 2W, Syst #1 S

1 0.2 0.8 2.2 NO S Trench, Sec 2W, Syst #2 S

5 0.2 4.8 13.5 NO S Trench, Sec 2W, Syst #3 S

2 0.2 1.8 5.1 NO S Trench, Sec 2W, Syst #4 S

1 0.2 0.8 2.2 NO S Trench, Sec 2W, Syst #5 S

0 0.2

-0.2

-0.6 NO S Trench, Sec 2W, Syst #6 S

1 0.2 0.8 2.2 NO S Trench, Sec 2W, Syst #7 S

8 0.2 7.8 21.9 NO S Trench, Sec 2W, Syst #8 S

8 0.2 7.8 21.9 NO S Trench, Sec 2W, Syst #9 S

29 0.2 28.8 80.9 NO S Trench, Sec 2W, Syst #10 S

6 0.2 5.8 16.3 NO S Trench, Sec 2W, Syst #11 S

35 0.2 34.8 97.7 NO S Trench, Sec 2W, Syst #12 S

3 0.2 2.8 7.9 NO S Trench, Sec 2W, Syst #13 S

1 0.2 0.8 2.2 NO S Trench, Sec 2W, Syst #14 S

0 0.2

-0.2

-0.6 NO S Trench, Sec 2W, Syst #15 S

4 0.2 3.8 10.7 NO S Trench, Sec 2W, Syst #16 S

4 0.2 3.8 10.7 NO S Trench, Sec 2W, Syst #17 S

4 0.2 3.8 10.7 NO S Trench, Sec 2W, Syst #18 S

3 0.2 2.8 7.9 NO S Trench, Sec 2W, Syst #19 S

1 0.2 0.8 2.2 NO S Trench, Sec 2W, Syst #20 S

0 0.2

-0.2

-0.6 NO S Trench, Sec 2W, Syst #21 S

8 0.2 7.8 21.9 NO S Trench, Sec 2W, Syst #22 S

0 0.2

-0.2

-0.6 NO Mean 15.3 Median 7.9 Minimum

-0.6 Maximum 97.7 Std Dev (1s) 25.2 South Trench Sec 2 W #W1-9 B

4 0.1 3.9 11.0 NO South Trench Sec 2 W #W1-10 B

20 0.1 19.9 55.9 NO South Trench Sec 2 W #W1-11 B

3 0.1 2.9 8.1 NO South Trench Sec 2 W #W1-12 B

5 0.1 4.9 13.8 NO South Trench Sec 2 W #W1-23 B

3 0.1 2.9 8.1 NO South Trench Sec 2 W #W2-2 B

2 0.1 1.9 5.3 NO South Trench Sec 2 W #W2-13 B

2 0.1 1.9 5.3 NO Mean 15.4 Median 8.1 Minimum 5.3 Maximum 55.9 Std Dev (1s) 18.1 Instrument Efficiency = Instrument 4-pi efficiency for alpha NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 2 - Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw S Trench, Sec 2W, Syst #1 S

48 47.6 0.4 1.5 NO S Trench, Sec 2W, Syst #2 S

50 47.6 2.4 8.9 NO S Trench, Sec 2W, Syst #3 S

51 47.6 3.4 12.6 NO S Trench, Sec 2W, Syst #4 S

62 47.6 14.4 53.5 NO S Trench, Sec 2W, Syst #5 S

58 47.6 10.4 38.6 NO S Trench, Sec 2W, Syst #6 S

57 47.6 9.4 34.9 NO S Trench, Sec 2W, Syst #7 S

60 47.6 12.4 46.1 NO S Trench, Sec 2W, Syst #8 S

52 47.6 4.4 16.3 NO S Trench, Sec 2W, Syst #9 S

48 47.6 0.4 1.5 NO S Trench, Sec 2W, Syst #10 S

61 47.6 13.4 49.8 NO S Trench, Sec 2W, Syst #11 S

42 47.6

-5.6

-20.8 NO S Trench, Sec 2W, Syst #12 S

61 47.6 13.4 49.8 NO S Trench, Sec 2W, Syst #13 S

51 47.6 3.4 12.6 NO S Trench, Sec 2W, Syst #14 S

42 47.6

-5.6

-20.8 NO S Trench, Sec 2W, Syst #15 S

49 47.6 1.4 5.2 NO S Trench, Sec 2W, Syst #16 S

47 47.6

-0.6

-2.2 NO S Trench, Sec 2W, Syst #17 S

41 47.6

-6.6

-24.5 NO S Trench, Sec 2W, Syst #18 S

38 47.6

-9.6

-35.7 NO S Trench, Sec 2W, Syst #19 S

44 47.6

-3.6

-13.4 NO S Trench, Sec 2W, Syst #20 S

59 47.6 11.4 42.4 NO S Trench, Sec 2W, Syst #21 S

53 47.6 5.4 20.1 NO S Trench, Sec 2W, Syst #22 S

55 47.6 7.4 27.5 NO Mean 13.8 Median 12.6 Minimum

-35.7 Maximum 53.5 Std Dev (1s) 26.8 South Trench Sec 2 W #W1-9 B

53 47.6 5.4 20.1 NO South Trench Sec 2 W #W1-10 B

61 47.6 13.4 49.8 NO South Trench Sec 2 W #W1-11 B

42 47.6

-5.6

-20.8 NO South Trench Sec 2 W #W1-12 B

47 47.6

-0.6

-2.2 NO South Trench Sec 2 W #W1-23 B

52 47.6 4.4 16.3 NO South Trench Sec 2 W #W2-2 B

56 47.6 8.4 31.2 NO South Trench Sec 2 W #W2-13 B

55 47.6 7.4 27.5 NO Mean 17.4 Median 20.1 Minimum

-20.8 Maximum 49.8 Std Dev (1s) 23.1 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 2 - Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3F, Sys #1 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3F, Sys #2 S

1 0.1 0.9 2.5 NO STrench, Sec 3F, Sys #3 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3F, Sys #4 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #5 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3F, Sys #6 S

2 0.1 1.9 5.3 NO STrench, Sec 3F, Sys #7 S

12 0.1 11.9 33.4 NO STrench, Sec 3F, Sys #8 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3F, Sys #9 S

4 0.1 3.9 11.0 NO STrench, Sec 3F, Sys #10 S

15 0.1 14.9 41.8 NO STrench, Sec 3F, Sys #11 S

17 0.1 16.9 47.5 NO STrench, Sec 3F, Sys #12 S

3 0.1 2.9 8.1 NO STrench, Sec 3F, Sys #13 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #14 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #15 S

1 0.1 0.9 2.5 NO STrench, Sec 3F, Sys #16 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #17 S

7 0.1 6.9 19.4 NO STrench, Sec 3F, Sys #18 S

4 0.1 3.9 11.0 NO STrench, Sec 3F, Sys #19 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #20 S

7 0.1 6.9 19.4 NO STrench, Sec 3F, Sys #21 S

5 0.1 4.9 13.8 NO STrench, Sec 3F, Sys #22 S

0 0.1

-0.1

-0.3 NO Mean 12.9 Median 13.8 Minimum

-0.3 Maximum 47.5 Std Dev (1s) 13.3 STrench, Sec 3 F, Grid# F11 B

6 0.1 5.9 16.6 NO STrench, Sec 3 Branch Off 2, F Grid# 1 B

1 0.1 0.9 2.5 NO Mean 9.5 Median 9.5 Minimum 2.5 Maximum 16.6 Std Dev (1s)

9.9 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3F, Sys #1 S

36 49.3

-13.3

-49.4 NO STrench, Sec 3F, Sys #2 S

62 49.3 12.7 47.2 NO STrench, Sec 3F, Sys #3 S

55 49.3 5.7 21.2 NO STrench, Sec 3F, Sys #4 S

45 49.3

-4.3

-16.0 NO STrench, Sec 3F, Sys #5 S

51 49.3 1.7 6.3 NO STrench, Sec 3F, Sys #6 S

33 49.3

-16.3

-60.6 NO STrench, Sec 3F, Sys #7 S

46 49.3

-3.3

-12.3 NO STrench, Sec 3F, Sys #8 S

55 49.3 5.7 21.2 NO STrench, Sec 3F, Sys #9 S

56 49.3 6.7 24.9 NO STrench, Sec 3F, Sys #10 S

49 49.3

-0.3

-1.1 NO STrench, Sec 3F, Sys #11 S

43 49.3

-6.3

-23.4 NO STrench, Sec 3F, Sys #12 S

45 49.3

-4.3

-16.0 NO STrench, Sec 3F, Sys #13 S

49 49.3

-0.3

-1.1 NO STrench, Sec 3F, Sys #14 S

50 49.3 0.7 2.6 NO STrench, Sec 3F, Sys #15 S

58 49.3 8.7 32.3 NO STrench, Sec 3F, Sys #16 S

50 49.3 0.7 2.6 NO STrench, Sec 3F, Sys #17 S

52 49.3 2.7 10.0 NO STrench, Sec 3F, Sys #18 S

44 49.3

-5.3

-19.7 NO STrench, Sec 3F, Sys #19 S

57 49.3 7.7 28.6 NO STrench, Sec 3F, Sys #20 S

35 49.3

-14.3

-53.1 NO STrench, Sec 3F, Sys #21 S

61 49.3 11.7 43.5 NO STrench, Sec 3F, Sys #22 S

49 49.3

-0.3

-1.1 NO Mean

-0.6 Median 2.6 Minimum

-60.6 Maximum 47.2 Std Dev (1s) 29.4 STrench, Sec 3 F, Grid# F11 B

56 49.3 6.7 24.9 NO STrench, Sec 3 Branch Off 2, F Grid# 1 B

54 49.3 4.7 17.5 NO Mean 21.2 Median 21.2 Minimum 17.5 Maximum 24.9 Std Dev (1s)

5.3 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W1, Sys #1 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #2 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #3 S

2 0.1 1.9 5.3 NO STrench, Sec 3W1, Sys #4 S

5 0.1 4.9 13.8 NO STrench, Sec 3W1, Sys #5 S

4 0.1 3.9 11.0 NO STrench, Sec 3W1, Sys #6 S

2 0.1 1.9 5.3 NO STrench, Sec 3W1, Sys #7 S

2 0.1 1.9 5.3 NO STrench, Sec 3W1, Sys #8 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #9 S

1 0.1 0.9 2.5 NO STrench, Sec 3W1, Sys #10 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #11 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #12 S

1 0.1 0.9 2.5 NO STrench, Sec 3W1, Sys #13 S

2 0.1 1.9 5.3 NO STrench, Sec 3W1, Sys #14 S

1 0.1 0.9 2.5 NO STrench, Sec 3W1, Sys #15 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #16 S

4 0.1 3.9 11.0 NO STrench, Sec 3W1, Sys #17 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #18 S

1 0.1 0.9 2.5 NO STrench, Sec 3W1, Sys #19 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #20 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W1, Sys #21 S

1 0.1 0.9 2.5 NO STrench, Sec 3W1, Sys #22 S

38 0.1 37.9 106.4 NO Mean 7.9 Median 2.5 Minimum

-0.3 Maximum 106.4 Std Dev (1s) 22.4 STrench, Sec 3 W1, Grid# 86 B

0 0.1

-0.1

-0.3 NO STrench, Sec 3 Branch Off 1, W2 Grid# 11 B

0 0.1

-0.1

-0.3 NO STrench, Sec 3 Branch Off 1, W2 Grid# 6 B

4 0.1 3.9 11.0 NO STrench, Sec 3 W2 Grid# 67 B

5 0.1 4.9 13.8 NO Mean 6.0 Median 5.3 Minimum

-0.3 Maximum 13.8 Std Dev (1s)

7.4 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 1 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W1, Sys #1 S

43 48.9

-5.9

-21.9 NO STrench, Sec 3W1, Sys #2 S

41 48.9

-7.9

-29.4 NO STrench, Sec 3W1, Sys #3 S

52 48.9 3.1 11.5 NO STrench, Sec 3W1, Sys #4 S

65 48.9 16.1 59.8 NO STrench, Sec 3W1, Sys #5 S

44 48.9

-4.9

-18.2 NO STrench, Sec 3W1, Sys #6 S

41 48.9

-7.9

-29.4 NO STrench, Sec 3W1, Sys #7 S

50 48.9 1.1 4.1 NO STrench, Sec 3W1, Sys #8 S

54 48.9 5.1 18.9 NO STrench, Sec 3W1, Sys #9 S

55 48.9 6.1 22.7 NO STrench, Sec 3W1, Sys #10 S

59 48.9 10.1 37.5 NO STrench, Sec 3W1, Sys #11 S

65 48.9 16.1 59.8 NO STrench, Sec 3W1, Sys #12 S

65 48.9 16.1 59.8 NO STrench, Sec 3W1, Sys #13 S

56 48.9 7.1 26.4 NO STrench, Sec 3W1, Sys #14 S

59 48.9 10.1 37.5 NO STrench, Sec 3W1, Sys #15 S

57 48.9 8.1 30.1 NO STrench, Sec 3W1, Sys #16 S

42 48.9

-6.9

-25.6 NO STrench, Sec 3W1, Sys #17 S

45 48.9

-3.9

-14.5 NO STrench, Sec 3W1, Sys #18 S

54 48.9 5.1 18.9 NO STrench, Sec 3W1, Sys #19 S

39 48.9

-9.9

-36.8 NO STrench, Sec 3W1, Sys #20 S

49 48.9 0.1 0.4 NO STrench, Sec 3W1, Sys #21 S

35 48.9

-13.9

-51.6 NO STrench, Sec 3W1, Sys #22 S

60 48.9 11.1 41.2 NO Mean 9.2 Median 18.9 Minimum

-51.6 Maximum 59.8 Std Dev (1s) 33.7 STrench, Sec 3 W1, Grid# 86 B

52 48.9 3.1 11.5 NO STrench, Sec 3 Branch Off 1, W2 Grid# 11 B

59 48.9 10.1 37.5 NO STrench, Sec 3 Branch Off 1, W2 Grid# 6 B

57 48.9 8.1 30.1 NO STrench, Sec 3 W2 Grid# 67 B

48 48.9

-0.9

-3.3 NO Mean 18.9 Median 20.8 Minimum

-3.3 Maximum 37.5 Std Dev (1s) 18.5 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 1 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W2, Sys #1 S

5 0.1 4.9 13.8 NO STrench, Sec 3W2, Sys #2 S

2 0.1 1.9 5.3 NO STrench, Sec 3W2, Sys #3 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #4 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #5 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #6 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #7 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #8 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #9 S

2 0.1 1.9 5.3 NO STrench, Sec 3W2, Sys #10 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #11 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #12 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #13 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #14 S

2 0.1 1.9 5.3 NO STrench, Sec 3W2, Sys #15 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #16 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #17 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #18 S

1 0.1 0.9 2.5 NO STrench, Sec 3W2, Sys #19 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #20 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #21 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W2, Sys #22 S

0 0.1

-0.1

-0.3 NO Mean 2.0 Median

-0.3 Minimum

-0.3 Maximum 13.8 Std Dev (1s) 3.3 STrench, Sec 3 W2 Grid# 37 B

0 0.1

-0.1

-0.3 NO STrench, Sec 3 W1, Grid# 54 B

3 0.1 2.9 8.1 NO STrench, Sec 3 W1, Grid# 42 B

0 0.1

-0.1

-0.3 NO Mean 2.5 Median

-0.3 Minimum

-0.3 Maximum 8.1 Std Dev (1s)

4.9 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 2 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W2, Sys #1 S

56 49.3 6.7 24.9 NO STrench, Sec 3W2, Sys #2 S

52 49.3 2.7 10.0 NO STrench, Sec 3W2, Sys #3 S

40 49.3

-9.3

-34.6 NO STrench, Sec 3W2, Sys #4 S

53 49.3 3.7 13.7 NO STrench, Sec 3W2, Sys #5 S

56 49.3 6.7 24.9 NO STrench, Sec 3W2, Sys #6 S

51 49.3 1.7 6.3 NO STrench, Sec 3W2, Sys #7 S

42 49.3

-7.3

-27.1 NO STrench, Sec 3W2, Sys #8 S

47 49.3

-2.3

-8.5 NO STrench, Sec 3W2, Sys #9 S

57 49.3 7.7 28.6 NO STrench, Sec 3W2, Sys #10 S

47 49.3

-2.3

-8.5 NO STrench, Sec 3W2, Sys #11 S

53 49.3 3.7 13.7 NO STrench, Sec 3W2, Sys #12 S

55 49.3 5.7 21.2 NO STrench, Sec 3W2, Sys #13 S

59 49.3 9.7 36.0 NO STrench, Sec 3W2, Sys #14 S

51 49.3 1.7 6.3 NO STrench, Sec 3W2, Sys #15 S

54 49.3 4.7 17.5 NO STrench, Sec 3W2, Sys #16 S

49 49.3

-0.3

-1.1 NO STrench, Sec 3W2, Sys #17 S

55 49.3 5.7 21.2 NO STrench, Sec 3W2, Sys #18 S

60 49.3 10.7 39.8 NO STrench, Sec 3W2, Sys #19 S

61 49.3 11.7 43.5 NO STrench, Sec 3W2, Sys #20 S

47 49.3

-2.3

-8.5 NO STrench, Sec 3W2, Sys #21 S

50 49.3 0.7 2.6 NO STrench, Sec 3W2, Sys #22 S

59 49.3 9.7 36.0 NO Mean 11.7 Median 13.7 Minimum

-34.6 Maximum 43.5 Std Dev (1s) 20.7 STrench, Sec 3 W2 Grid# 37 B

44 49.3

-5.3

-19.7 NO STrench, Sec 3 W1, Grid# 54 B

59 49.3 9.7 36.0 NO STrench, Sec 3 W1, Grid# 42 B

66 49.3 16.7 62.0 NO Mean 26.1 Median 36.0 Minimum

-19.7 Maximum 62.0 Std Dev (1s) 41.8 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 2 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W3, Sys #1 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #2 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #3 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #4 S

1 0.1 0.9 2.5 NO STrench, Sec 3W3, Sys #5 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #6 S

1 0.1 0.9 2.5 NO STrench, Sec 3W3, Sys #7 S

3 0.1 2.9 8.1 NO STrench, Sec 3W3, Sys #8 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #9 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #10 S

1 0.1 0.9 2.5 NO STrench, Sec 3W3, Sys #11 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #12 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #13 S

2 0.1 1.9 5.3 NO STrench, Sec 3W3, Sys #14 S

1 0.1 0.9 2.5 NO STrench, Sec 3W3, Sys #15 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #16 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #17 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #18 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #19 S

0 0.1

-0.1

-0.3 NO STrench, Sec 3W3, Sys #20 S

0 0.1

-0.1

-0.3 NO Mean 1.0 Median

-0.3 Minimum

-0.3 Maximum 8.1 Std Dev (1s) 2.3 STrench, Sec 3 W3 Grid# 31 B

1 0.1 0.9 2.5 NO STrench, Sec 3 W3 Grid# 32 B

1 0.1 0.9 2.5 NO Mean 2.5 Median 2.5 Minimum 2.5 Maximum 2.5 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 3 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw STrench, Sec 3W3, Sys #1 S

52 49.3 2.7 10.0 NO STrench, Sec 3W3, Sys #2 S

54 49.3 4.7 17.5 NO STrench, Sec 3W3, Sys #3 S

40 49.3

-9.3

-34.6 NO STrench, Sec 3W3, Sys #4 S

51 49.3 1.7 6.3 NO STrench, Sec 3W3, Sys #5 S

46 49.3

-3.3

-12.3 NO STrench, Sec 3W3, Sys #6 S

48 49.3

-1.3

-4.8 NO STrench, Sec 3W3, Sys #7 S

49 49.3

-0.3

-1.1 NO STrench, Sec 3W3, Sys #8 S

50 49.3 0.7 2.6 NO STrench, Sec 3W3, Sys #9 S

42 49.3

-7.3

-27.1 NO STrench, Sec 3W3, Sys #10 S

52 49.3 2.7 10.0 NO STrench, Sec 3W3, Sys #11 S

39 49.3

-10.3

-38.3 NO STrench, Sec 3W3, Sys #12 S

46 49.3

-3.3

-12.3 NO STrench, Sec 3W3, Sys #13 S

50 49.3 0.7 2.6 NO STrench, Sec 3W3, Sys #14 S

48 49.3

-1.3

-4.8 NO STrench, Sec 3W3, Sys #15 S

48 49.3

-1.3

-4.8 NO STrench, Sec 3W3, Sys #16 S

51 49.3 1.7 6.3 NO STrench, Sec 3W3, Sys #17 S

57 49.3 7.7 28.6 NO STrench, Sec 3W3, Sys #18 S

53 49.3 3.7 13.7 NO STrench, Sec 3W3, Sys #19 S

49 49.3

-0.3

-1.1 NO STrench, Sec 3W3, Sys #20 S

51 49.3 1.7 6.3 NO Mean

-1.9 Median

-1.1 Minimum

-38.3 Maximum 28.6 Std Dev (1s) 16.8 STrench, Sec 3 W3 Grid# 31 B

58 48.9 9.1 33.8 NO STrench, Sec 3 W3 Grid# 32 B

44 48.9

-4.9

-18.2 NO Mean 7.8 Median 7.8 Minimum

-18.2 Maximum 33.8 Std Dev (1s) 36.8 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 3 - Wall Survey Unit 3 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 F1, Sys #1 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #2 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #3 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #4 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F1, Sys #5 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #6 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F1, Sys #7 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #8 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #9 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #10 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #11 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #12 S

2 0.5 1.5 4.2 NO Strench, Sec 4 F1, Sys #13 S

2 0.5 1.5 4.2 NO Strench, Sec 4 F1, Sys #14 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #15 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F1, Sys #16 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #17 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #18 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #19 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F1, Sys #20 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F1, Sys #21 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F1, Sys #22 S

0 0.5

-0.5

-1.4 NO Mean

-0.3 Median

-1.4 Minimum

-1.4 Maximum 4.2 Std Dev (1s)

1.9 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Floor Survey Unit 1 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 F1, Sys #1 S

53 51.0 2.0 7.4 NO Strench, Sec 4 F1, Sys #2 S

56 51.0 5.0 18.6 NO Strench, Sec 4 F1, Sys #3 S

57 51.0 6.0 22.3 NO Strench, Sec 4 F1, Sys #4 S

56 51.0 5.0 18.6 NO Strench, Sec 4 F1, Sys #5 S

50 51.0

-1.0

-3.7 NO Strench, Sec 4 F1, Sys #6 S

56 51.0 5.0 18.6 NO Strench, Sec 4 F1, Sys #7 S

55 51.0 4.0 14.9 NO Strench, Sec 4 F1, Sys #8 S

43 51.0

-8.0

-29.7 NO Strench, Sec 4 F1, Sys #9 S

58 51.0 7.0 26.0 NO Strench, Sec 4 F1, Sys #10 S

40 51.0

-11.0

-40.9 NO Strench, Sec 4 F1, Sys #11 S

55 51.0 4.0 14.9 NO Strench, Sec 4 F1, Sys #12 S

55 51.0 4.0 14.9 NO Strench, Sec 4 F1, Sys #13 S

46 51.0

-5.0

-18.6 NO Strench, Sec 4 F1, Sys #14 S

38 51.0

-13.0

-48.3 NO Strench, Sec 4 F1, Sys #15 S

50 51.0

-1.0

-3.7 NO Strench, Sec 4 F1, Sys #16 S

59 51.0 8.0 29.7 NO Strench, Sec 4 F1, Sys #17 S

60 51.0 9.0 33.4 NO Strench, Sec 4 F1, Sys #18 S

50 51.0

-1.0

-3.7 NO Strench, Sec 4 F1, Sys #19 S

55 51.0 4.0 14.9 NO Strench, Sec 4 F1, Sys #20 S

58 51.0 7.0 26.0 NO Strench, Sec 4 F1, Sys #21 S

51 51.0 0.0 0.0 NO Strench, Sec 4 F1, Sys #22 S

57 51.0 6.0 22.3 NO Mean 6.1 Median 14.9 Minimum

-48.3 Maximum 33.4 Std Dev (1s) 22.7 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Floor Survey Unit 1 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 F2, Sys #1 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #2 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #3 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #4 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #5 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F2, Sys #6 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #7 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F2, Sys #8 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F2, Sys #9 S

1 0.5 0.5 1.4 NO Strench, Sec 4 F2, Sys #10 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #11 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #12 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #13 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #14 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #15 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #16 S

0 0.5

-0.5

-1.4 NO Strench, Sec 4 F2, Sys #17 S

0 0.5

-0.5

-1.4 NO Mean

-0.7 Median

-1.4 Minimum

-1.4 Maximum 1.4 Std Dev (1s)

1.2 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Floor Survey Unit 2 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 F2, Sys #1 S

42 51.0

-9.0

-33.4 NO Strench, Sec 4 F2, Sys #2 S

47 51.0

-4.0

-14.9 NO Strench, Sec 4 F2, Sys #3 S

60 51.0 9.0 33.4 NO Strench, Sec 4 F2, Sys #4 S

45 51.0

-6.0

-22.3 NO Strench, Sec 4 F2, Sys #5 S

57 51.0 6.0 22.3 NO Strench, Sec 4 F2, Sys #6 S

47 51.0

-4.0

-14.9 NO Strench, Sec 4 F2, Sys #7 S

45 51.0

-6.0

-22.3 NO Strench, Sec 4 F2, Sys #8 S

51 51.0 0.0 0.0 NO Strench, Sec 4 F2, Sys #9 S

53 51.0 2.0 7.4 NO Strench, Sec 4 F2, Sys #10 S

50 51.0

-1.0

-3.7 NO Strench, Sec 4 F2, Sys #11 S

54 51.0 3.0 11.1 NO Strench, Sec 4 F2, Sys #12 S

42 51.0

-9.0

-33.4 NO Strench, Sec 4 F2, Sys #13 S

46 51.0

-5.0

-18.6 NO Strench, Sec 4 F2, Sys #14 S

42 51.0

-9.0

-33.4 NO Strench, Sec 4 F2, Sys #15 S

45 51.0

-6.0

-22.3 NO Strench, Sec 4 F2, Sys #16 S

40 51.0

-11.0

-40.9 NO Strench, Sec 4 F2, Sys #17 S

49 51.0

-2.0

-7.4 NO Mean

-11.4 Median

-14.9 Minimum

-40.9 Maximum 33.4 Std Dev (1s) 20.9 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Floor Survey Unit 2 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W1, Sys #1 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #2 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #3 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #4 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #5 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #6 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #7 S

2 0.1 1.9 5.3 NO Strench, Sec 4 W1, Sys #8 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W1, Sys #9 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #10 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #11 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #12 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W1, Sys #13 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #14 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #15 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #16 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W1, Sys #17 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #18 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #19 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #20 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W1, Sys #21 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W1, Sys #22 S

0 0.1

-0.1

-0.3 NO Mean 0.5 Median

-0.3 Minimum

-0.3 Maximum 5.3 Std Dev (1s) 1.5 Strench, Sec 4 Wall 2 (North) top, Grid #129 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #129 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #123 B

0 0.1

-0.1

-0.3 NO Mean

-0.3 Median

-0.3 Minimum

-0.3 Maximum

-0.3 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 1 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W1, Sys #1 S

43 50.4

-7.4

-27.5 NO Strench, Sec 4 W1, Sys #2 S

45 50.4

-5.4

-20.1 NO Strench, Sec 4 W1, Sys #3 S

47 50.4

-3.4

-12.6 NO Strench, Sec 4 W1, Sys #4 S

53 50.4 2.6 9.7 NO Strench, Sec 4 W1, Sys #5 S

56 50.4 5.6 20.8 NO Strench, Sec 4 W1, Sys #6 S

44 50.4

-6.4

-23.8 NO Strench, Sec 4 W1, Sys #7 S

55 50.4 4.6 17.1 NO Strench, Sec 4 W1, Sys #8 S

48 50.4

-2.4

-8.9 NO Strench, Sec 4 W1, Sys #9 S

65 50.4 14.6 54.2 NO Strench, Sec 4 W1, Sys #10 S

48 50.4

-2.4

-8.9 NO Strench, Sec 4 W1, Sys #11 S

52 50.4 1.6 5.9 NO Strench, Sec 4 W1, Sys #12 S

55 50.4 4.6 17.1 NO Strench, Sec 4 W1, Sys #13 S

56 50.4 5.6 20.8 NO Strench, Sec 4 W1, Sys #14 S

55 50.4 4.6 17.1 NO Strench, Sec 4 W1, Sys #15 S

47 50.4

-3.4

-12.6 NO Strench, Sec 4 W1, Sys #16 S

40 50.4

-10.4

-38.6 NO Strench, Sec 4 W1, Sys #17 S

45 50.4

-5.4

-20.1 NO Strench, Sec 4 W1, Sys #18 S

58 50.4 7.6 28.2 NO Strench, Sec 4 W1, Sys #19 S

43 50.4

-7.4

-27.5 NO Strench, Sec 4 W1, Sys #20 S

62 50.4 11.6 43.1 NO Strench, Sec 4 W1, Sys #21 S

45 50.4

-5.4

-20.1 NO Strench, Sec 4 W1, Sys #22 S

51 50.4 0.6 2.2 NO Mean 0.7 Median

-3.3 Minimum

-38.6 Maximum 54.2 Std Dev (1s) 24.6 Strench, Sec 4 Wall 2 (North) top, Grid #129 B

53 53.2

-0.2

-0.7 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #129 B

55 53.2 1.8 6.7 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #123 B

37 53.2

-16.2

-60.2 NO Mean

-18.1 Median

-0.7 Minimum

-60.2 Maximum 6.7 Std Dev (1s) 36.7 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 1 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W2, Sys #1 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #2 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #3 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #4 S

2 0.1 1.9 5.3 NO Strench, Sec 4 W2, Sys #5 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #6 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #7 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #8 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #9 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #10 S

2 0.1 1.9 5.3 NO Strench, Sec 4 W2, Sys #11 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #12 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #13 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #14 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #15 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #16 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #17 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #18 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W2, Sys #19 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #20 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #21 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W2, Sys #22 S

1 0.1 0.9 2.5 NO Mean 1.3 Median

-0.3 Minimum

-0.3 Maximum 5.3 Std Dev (1s) 1.9 Strench, Sec 4 Wall 2 (North) bottom, Grid #96 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #94 B

1 0.1 0.9 2.5 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #95 B

0 0.1

-0.1

-0.3 NO Mean 0.7 Median

-0.3 Minimum

-0.3 Maximum 2.5 Std Dev (1s)

1.6 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 2 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W2, Sys #1 S

53 51.5 1.5 5.6 NO Strench, Sec 4 W2, Sys #2 S

54 51.5 2.5 9.3 NO Strench, Sec 4 W2, Sys #3 S

52 51.5 0.5 1.9 NO Strench, Sec 4 W2, Sys #4 S

51 51.5

-0.5

-1.9 NO Strench, Sec 4 W2, Sys #5 S

46 51.5

-5.5

-20.4 NO Strench, Sec 4 W2, Sys #6 S

55 51.5 3.5 13.0 NO Strench, Sec 4 W2, Sys #7 S

48 51.5

-3.5

-13.0 NO Strench, Sec 4 W2, Sys #8 S

41 51.5

-10.5

-39.0 NO Strench, Sec 4 W2, Sys #9 S

47 51.5

-4.5

-16.7 NO Strench, Sec 4 W2, Sys #10 S

43 51.5

-8.5

-31.6 NO Strench, Sec 4 W2, Sys #11 S

39 51.5

-12.5

-46.4 NO Strench, Sec 4 W2, Sys #12 S

52 51.5 0.5 1.9 NO Strench, Sec 4 W2, Sys #13 S

61 51.5 9.5 35.3 NO Strench, Sec 4 W2, Sys #14 S

51 51.5

-0.5

-1.9 NO Strench, Sec 4 W2, Sys #15 S

64 51.5 12.5 46.4 NO Strench, Sec 4 W2, Sys #16 S

55 51.5 3.5 13.0 NO Strench, Sec 4 W2, Sys #17 S

56 51.5 4.5 16.7 NO Strench, Sec 4 W2, Sys #18 S

60 51.5 8.5 31.6 NO Strench, Sec 4 W2, Sys #19 S

54 51.5 2.5 9.3 NO Strench, Sec 4 W2, Sys #20 S

50 51.5

-1.5

-5.6 NO Strench, Sec 4 W2, Sys #21 S

49 51.5

-2.5

-9.3 NO Strench, Sec 4 W2, Sys #22 S

50 51.5

-1.5

-5.6 NO Mean

-0.3 Median 0.0 Minimum

-46.4 Maximum 46.4 Std Dev (1s) 22.8 Strench, Sec 4 Wall 2 (North) bottom, Grid #96 B

49 53.2

-4.2

-15.6 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #94 B

47 53.2

-6.2

-23.0 NO Strench, Sec 4 Wall 1 (South) bottom, Grid #95 B

42 53.2

-11.2

-41.6 NO Mean

-26.8 Median

-23.0 Minimum

-41.6 Maximum

-15.6 Std Dev (1s) 13.4 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 2 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W3, Sys #1 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #2 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #3 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #4 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #5 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #6 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #7 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #8 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #9 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #10 S

2 0.1 1.9 5.3 NO Strench, Sec 4 W3, Sys #11 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #12 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #13 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #14 S

2 0.1 1.9 5.3 NO Strench, Sec 4 W3, Sys #15 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #16 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #17 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #18 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #19 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #20 S

0 0.1

-0.1

-0.3 NO Strench, Sec 4 W3, Sys #21 S

1 0.1 0.9 2.5 NO Strench, Sec 4 W3, Sys #22 S

1 0.1 0.9 2.5 NO Mean 1.1 Median

-0.3 Minimum

-0.3 Maximum 5.3 Std Dev (1s) 1.9 Strench, Sec 4 Wall 2 (North) bottom, Grid #3 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) top, Grid #12 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #12 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2(North) bottom, Grid #20 B

1 0.1 0.9 2.5 NO Strench, Sec 4 Wall 2 (North) top, Grid #23 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) top, Grid #28 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #39 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) top, Grid #53 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 2 (North) top, Grid #56 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #2 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #10 B

2 0.1 1.9 5.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #19 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #32 B

0 0.1

-0.1

-0.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #61 B

1 0.1 0.9 2.5 NO Mean 0.5 Median

-0.3 Minimum

-0.3 Maximum 5.3 Std Dev (1s)

1.7 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 3 - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench, Sec 4 W3, Sys #1 S

60 51.5 8.5 31.6 NO Strench, Sec 4 W3, Sys #2 S

55 51.5 3.5 13.0 NO Strench, Sec 4 W3, Sys #3 S

50 51.5

-1.5

-5.6 NO Strench, Sec 4 W3, Sys #4 S

39 51.5

-12.5

-46.4 NO Strench, Sec 4 W3, Sys #5 S

50 51.5

-1.5

-5.6 NO Strench, Sec 4 W3, Sys #6 S

43 51.5

-8.5

-31.6 NO Strench, Sec 4 W3, Sys #7 S

52 51.5 0.5 1.9 NO Strench, Sec 4 W3, Sys #8 S

50 51.5

-1.5

-5.6 NO Strench, Sec 4 W3, Sys #9 S

37 51.5

-14.5

-53.9 NO Strench, Sec 4 W3, Sys #10 S

52 51.5 0.5 1.9 NO Strench, Sec 4 W3, Sys #11 S

39 51.5

-12.5

-46.4 NO Strench, Sec 4 W3, Sys #12 S

38 51.5

-13.5

-50.2 NO Strench, Sec 4 W3, Sys #13 S

57 51.5 5.5 20.4 NO Strench, Sec 4 W3, Sys #14 S

55 51.5 3.5 13.0 NO Strench, Sec 4 W3, Sys #15 S

40 51.5

-11.5

-42.7 NO Strench, Sec 4 W3, Sys #16 S

43 51.5

-8.5

-31.6 NO Strench, Sec 4 W3, Sys #17 S

57 51.5 5.5 20.4 NO Strench, Sec 4 W3, Sys #18 S

42 51.5

-9.5

-35.3 NO Strench, Sec 4 W3, Sys #19 S

60 51.5 8.5 31.6 NO Strench, Sec 4 W3, Sys #20 S

48 51.5

-3.5

-13.0 NO Strench, Sec 4 W3, Sys #21 S

47 51.5

-4.5

-16.7 NO Strench, Sec 4 W3, Sys #22 S

49 51.5

-2.5

-9.3 NO Mean

-11.8 Median

-7.4 Minimum

-53.9 Maximum 31.6 Std Dev (1s) 27.2 Strench, Sec 4 Wall 2 (North) bottom, Grid #3 B

52 51.5 0.5 1.9 NO Strench, Sec 4 Wall 2 (North) top, Grid #12 B

49 51.5

-2.5

-9.3 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #12 B

45 51.5

-6.5

-24.2 NO Strench, Sec 4 Wall 2(North) bottom, Grid #20 B

56 51.5 4.5 16.7 NO Strench, Sec 4 Wall 2 (North) top, Grid #23 B

59 51.5 7.5 27.9 NO Strench, Sec 4 Wall 2 (North) top, Grid #28 B

54 51.5 2.5 9.3 NO Strench, Sec 4 Wall 2 (North) bottom, Grid #39 B

52 51.5 0.5 1.9 NO Strench, Sec 4 Wall 2 (North) top, Grid #53 B

43 51.5

-8.5

-31.6 NO Strench, Sec 4 Wall 2 (North) top, Grid #56 B

47 51.5

-4.5

-16.7 NO Strench, Sec 4 Wall 1 (South) top, Grid #2 B

42 51.5

-9.5

-35.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #10 B

49 51.5

-2.5

-9.3 NO Strench, Sec 4 Wall 1 (South) top, Grid #19 B

58 51.5 6.5 24.2 NO Strench, Sec 4 Wall 1 (South) top, Grid #32 B

56 51.5 4.5 16.7 NO Strench, Sec 4 Wall 1 (South) top, Grid #61 B

50 51.5

-1.5

-5.6 NO Mean

-2.4 Median

-1.9 Minimum

-35.3 Maximum 27.9 Std Dev (1s) 20.1 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 4 - Wall Survey Unit 3 - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw ST,Sec5,FL, Sys#1 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#2 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#3 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#4 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#5 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#6 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#7 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#8 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#9 S

2 0.1 1.9 5.3 NO ST,Sec5,FL, Sys#10 S

3 0.1 2.9 8.1 NO ST,Sec5,FL, Sys#11 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#12 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#13 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#14 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#15 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#16 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#17 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#18 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#19 S

2 0.1 1.9 5.3 NO ST,Sec5,FL, Sys#20 S

1 0.1 0.9 2.5 NO ST,Sec5,FL, Sys#21 S

0 0.1

-0.1

-0.3 NO ST,Sec5,FL, Sys#22 S

0 0.1

-0.1

-0.3 NO Mean 1.5 Median

-0.3 Minimum

-0.3 Maximum 8.1 Std Dev (1s) 2.4 ST,Sec5,FL,Bias Grid#12 B

0 0.4

-0.4

-1.1 NO ST,Sec5,FL,Bias Grid#18 B

1 0.4 0.6 1.7 NO ST,Sec5,FL,Bias Grid#19 B

0 0.4

-0.4

-1.1 NO ST,Sec5,FL,Bias Grid#46 B

0 0.4

-0.4

-1.1 NO ST,Sec5,FL,Bias Grid#50 B

0 0.4

-0.4

-1.1 NO ST,Sec5,FL,Bias Grid#52 B

1 0.4 0.6 1.7 NO ST,Sec5,FL,Bias Grid#53 B

0 0.4

-0.4

-1.1 NO ST,Sec5,FL,Bias Grid#55 B

1 0.4 0.6 1.7 NO Mean

-0.1 Median

-1.1 Minimum

-1.1 Maximum 1.7 Std Dev (1s)

1.5 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 5 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw ST,Sec5,FL, Sys#1 S

48 53.8

-5.8

-21.5 NO ST,Sec5,FL, Sys#2 S

49 53.8

-4.8

-17.8 NO ST,Sec5,FL, Sys#3 S

51 53.8

-2.8

-10.4 NO ST,Sec5,FL, Sys#4 S

56 53.8 2.2 8.2 NO ST,Sec5,FL, Sys#5 S

55 53.8 1.2 4.5 NO ST,Sec5,FL, Sys#6 S

46 53.8

-7.8

-29.0 NO ST,Sec5,FL, Sys#7 S

43 53.8

-10.8

-40.1 NO ST,Sec5,FL, Sys#8 S

55 53.8 1.2 4.5 NO ST,Sec5,FL, Sys#9 S

60 53.8 6.2 23.0 NO ST,Sec5,FL, Sys#10 S

54 53.8 0.2 0.7 NO ST,Sec5,FL, Sys#11 S

61 53.8 7.2 26.8 NO ST,Sec5,FL, Sys#12 S

45 53.8

-8.8

-32.7 NO ST,Sec5,FL, Sys#13 S

46 53.8

-7.8

-29.0 NO ST,Sec5,FL, Sys#14 S

47 53.8

-6.8

-25.3 NO ST,Sec5,FL, Sys#15 S

68 53.8 14.2 52.8 NO ST,Sec5,FL, Sys#16 S

65 53.8 11.2 41.6 NO ST,Sec5,FL, Sys#17 S

47 53.8

-6.8

-25.3 NO ST,Sec5,FL, Sys#18 S

58 53.8 4.2 15.6 NO ST,Sec5,FL, Sys#19 S

49 53.8

-4.8

-17.8 NO ST,Sec5,FL, Sys#20 S

45 53.8

-8.8

-32.7 NO ST,Sec5,FL, Sys#21 S

43 53.8

-10.8

-40.1 NO ST,Sec5,FL, Sys#22 S

59 53.8 5.2 19.3 NO Mean

-5.7 Median

-10.4 Minimum

-40.1 Maximum 52.8 Std Dev (1s) 27.0 ST,Sec5,FL,Bias Grid#12 B

62 51.2 10.8 40.1 NO ST,Sec5,FL,Bias Grid#18 B

56 51.2 4.8 17.8 NO ST,Sec5,FL,Bias Grid#19 B

47 51.2

-4.2

-15.6 NO ST,Sec5,FL,Bias Grid#46 B

46 51.2

-5.2

-19.3 NO ST,Sec5,FL,Bias Grid#50 B

48 51.2

-3.2

-11.9 NO ST,Sec5,FL,Bias Grid#52 B

47 51.2

-4.2

-15.6 NO ST,Sec5,FL,Bias Grid#53 B

51 51.2

-0.2

-0.7 NO ST,Sec5,FL,Bias Grid#55 B

60 51.2 8.8 32.7 NO Mean 3.4 Median

-6.3 Minimum

-19.3 Maximum 40.1 Std Dev (1s) 23.6 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 5 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench,Sec5W,Sys#1 S

1 0.2 0.8 2.2 NO Strench,Sec5W,Sys#2 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#3 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#4 S

1 0.2 0.8 2.2 NO Strench,Sec5W,Sys#5 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#6 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#7 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#8 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#9 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#10 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#11 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#12 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#13 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#14 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#15 S

1 0.2 0.8 2.2 NO Strench,Sec5W,Sys#16 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#17 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#18 S

2 0.2 1.8 5.1 NO Strench,Sec5W,Sys#19 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#20 S

1 0.2 0.8 2.2 NO Strench,Sec5W,Sys#21 S

0 0.2

-0.2

-0.6 NO Strench,Sec5W,Sys#22 S

0 0.2

-0.2

-0.6 NO Mean 0.2 Median

-0.6 Minimum

-0.6 Maximum 5.1 Std Dev (1s) 1.5 ST,Sec5,SW,Bias#3B B

0 0.1

-0.1

-0.3 NO ST,Sec5,SW,Bias#9T B

0 0.1

-0.1

-0.3 NO ST,Sec5,SW,Bias#9B B

0 0.1

-0.1

-0.3 NO ST,Sec5,SW,Bias#15T B

0 0.1

-0.1

-0.3 NO ST,Sec5,SW,Bias#28T B

0 0.1

-0.1

-0.3 NO ST,Sec5,SW,Bias#28B B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#12T B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#12B B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#17B B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#31T B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#32B B

0 0.1

-0.1

-0.3 NO ST,Sec5,NW,Bias#40T B

0 0.1

-0.1

-0.3 NO Mean

-0.3 Median

-0.3 Minimum

-0.3 Maximum

-0.3 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 5 - Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Strench,Sec5W,Sys#1 S

52 48.2 3.8 14.1 NO Strench,Sec5W,Sys#2 S

42 48.2

-6.2

-23.0 NO Strench,Sec5W,Sys#3 S

50 48.2 1.8 6.7 NO Strench,Sec5W,Sys#4 S

49 48.2 0.8 3.0 NO Strench,Sec5W,Sys#5 S

48 48.2

-0.2

-0.7 NO Strench,Sec5W,Sys#6 S

38 48.2

-10.2

-37.9 NO Strench,Sec5W,Sys#7 S

62 48.2 13.8 51.3 NO Strench,Sec5W,Sys#8 S

46 48.2

-2.2

-8.2 NO Strench,Sec5W,Sys#9 S

52 48.2 3.8 14.1 NO Strench,Sec5W,Sys#10 S

51 48.2 2.8 10.4 NO Strench,Sec5W,Sys#11 S

55 48.2 6.8 25.3 NO Strench,Sec5W,Sys#12 S

49 48.2 0.8 3.0 NO Strench,Sec5W,Sys#13 S

48 48.2

-0.2

-0.7 NO Strench,Sec5W,Sys#14 S

47 48.2

-1.2

-4.5 NO Strench,Sec5W,Sys#15 S

51 48.2 2.8 10.4 NO Strench,Sec5W,Sys#16 S

58 48.2 9.8 36.4 NO Strench,Sec5W,Sys#17 S

56 48.2 7.8 29.0 NO Strench,Sec5W,Sys#18 S

50 48.2 1.8 6.7 NO Strench,Sec5W,Sys#19 S

53 48.2 4.8 17.8 NO Strench,Sec5W,Sys#20 S

44 48.2

-4.2

-15.6 NO Strench,Sec5W,Sys#21 S

56 48.2 7.8 29.0 NO Strench,Sec5W,Sys#22 S

51 48.2 2.8 10.4 NO Mean 8.0 Median 6.7 Minimum

-37.9 Maximum 51.3 Std Dev (1s) 19.9 ST,Sec5,SW,Bias#3B B

59 53.8 5.2 19.3 NO ST,Sec5,SW,Bias#9T B

47 53.8

-6.8

-25.3 NO ST,Sec5,SW,Bias#9B B

49 53.8

-4.8

-17.8 NO ST,Sec5,SW,Bias#15T B

61 53.8 7.2 26.8 NO ST,Sec5,SW,Bias#28T B

51 53.8

-2.8

-10.4 NO ST,Sec5,SW,Bias#28B B

41 53.8

-12.8

-47.6 NO ST,Sec5,NW,Bias#12T B

58 53.8 4.2 15.6 NO ST,Sec5,NW,Bias#12B B

55 53.8 1.2 4.5 NO ST,Sec5,NW,Bias#17B B

54 53.8 0.2 0.7 NO ST,Sec5,NW,Bias#31T B

48 53.8

-5.8

-21.5 NO ST,Sec5,NW,Bias#32B B

44 53.8

-9.8

-36.4 NO ST,Sec5,NW,Bias#40T B

52 53.8

-1.8

-6.7 NO Mean

-8.2 Median

-8.5 Minimum

-47.6 Maximum 26.8 Std Dev (1s) 22.8 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute South Trench Section 5 - Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw LateralTrench, Section 6F-1, Sys #1, Grid #1 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #2, Grid #2 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #3, Grid #4 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #4, Grid #5 S

2 0.1 1.9 5.3 NO LateralTrench, Section 6F-1, Sys #5, Grid #7 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #6, Grid #8 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #7, Grid #10 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #8, Grid #11 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #9, Grid #13 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #10, Grid #14 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #11, Grid #16 S

2 0.1 1.9 5.3 NO LateralTrench, Section 6F-1, Sys #12, Grid #17 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #13, Grid #19 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #14, Grid #20 S

3 0.1 2.9 8.1 NO LateralTrench, Section 6F-1, Sys #15, Grid #22 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #16, Grid #23 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #17, Grid #25 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #18, Grid #26 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #19, Grid #28 S

1 0.1 0.9 2.5 NO LateralTrench, Section 6F-1, Sys #20, Grid #29 S

0 0.1

-0.1

-0.3 NO LateralTrench, Section 6F-1, Sys #21, Grid #31 S

2 0.1 1.9 5.3 NO LateralTrench, Section 6F-1, Sys #22, Grid #32 S

0 0.1

-0.1

-0.3 NO Mean 1.8 Median 2.5 Minimum

-0.3 Maximum 8.1 Std Dev (1s) 2.5 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO Mean

-1.1 Median

-1.1 Minimum

-1.1 Maximum

-1.1 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Lateral Trench Section 6 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw LateralTrench, Section 6F-1, Sys #1, Grid #1 S

51 53.8

-2.8

-10.4 NO LateralTrench, Section 6F-1, Sys #2, Grid #2 S

55 53.8 1.2 4.5 NO LateralTrench, Section 6F-1, Sys #3, Grid #4 S

48 53.8

-5.8

-21.5 NO LateralTrench, Section 6F-1, Sys #4, Grid #5 S

52 53.8

-1.8

-6.7 NO LateralTrench, Section 6F-1, Sys #5, Grid #7 S

60 53.8 6.2 23.0 NO LateralTrench, Section 6F-1, Sys #6, Grid #8 S

57 53.8 3.2 11.9 NO LateralTrench, Section 6F-1, Sys #7, Grid #10 S

47 53.8

-6.8

-25.3 NO LateralTrench, Section 6F-1, Sys #8, Grid #11 S

50 53.8

-3.8

-14.1 NO LateralTrench, Section 6F-1, Sys #9, Grid #13 S

53 53.8

-0.8

-3.0 NO LateralTrench, Section 6F-1, Sys #10, Grid #14 S

60 53.8 6.2 23.0 NO LateralTrench, Section 6F-1, Sys #11, Grid #16 S

49 53.8

-4.8

-17.8 NO LateralTrench, Section 6F-1, Sys #12, Grid #17 S

50 53.8

-3.8

-14.1 NO LateralTrench, Section 6F-1, Sys #13, Grid #19 S

50 53.8

-3.8

-14.1 NO LateralTrench, Section 6F-1, Sys #14, Grid #20 S

64 53.8 10.2 37.9 NO LateralTrench, Section 6F-1, Sys #15, Grid #22 S

61 53.8 7.2 26.8 NO LateralTrench, Section 6F-1, Sys #16, Grid #23 S

44 53.8

-9.8

-36.4 NO LateralTrench, Section 6F-1, Sys #17, Grid #25 S

56 53.8 2.2 8.2 NO LateralTrench, Section 6F-1, Sys #18, Grid #26 S

59 53.8 5.2 19.3 NO LateralTrench, Section 6F-1, Sys #19, Grid #28 S

63 53.8 9.2 34.2 NO LateralTrench, Section 6F-1, Sys #20, Grid #29 S

49 53.8

-4.8

-17.8 NO LateralTrench, Section 6F-1, Sys #21, Grid #31 S

67 53.8 13.2 49.0 NO LateralTrench, Section 6F-1, Sys #22, Grid #32 S

62 53.8 8.2 30.5 NO Mean 4.0 Median 4.5 Minimum

-36.4 Maximum 49.0 Std Dev (1s) 23.7 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO Mean

-190.2 Median

-190.2 Minimum

-190.2 Maximum

-190.2 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Lateral Trench Section 6 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw North Trench, Columns 16 to 18, Floor, Sys #1 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #2 S

1 0.1 0.9 2.5 NO North Trench, Columns 16 to 18, Floor, Sys #3 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #4 S

1 0.1 0.9 2.5 NO North Trench, Columns 16 to 18, Floor, Sys #5 S

3 0.1 2.9 8.1 NO North Trench, Columns 16 to 18, Floor, Sys #6 S

2 0.1 1.9 5.3 NO North Trench, Columns 16 to 18, Floor, Sys #7 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #8 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #9 S

1 0.1 0.9 2.5 NO North Trench, Columns 16 to 18, Floor, Sys #10 S

5 0.1 4.9 13.8 NO North Trench, Columns 16 to 18, Floor, Sys #11 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #12 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #13 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #14 S

1 0.1 0.9 2.5 NO North Trench, Columns 16 to 18, Floor, Sys #15 S

3 0.1 2.9 8.1 NO North Trench, Columns 16 to 18, Floor, Sys #16 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #17 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #18 S

2 0.1 1.9 5.3 NO North Trench, Columns 16 to 18, Floor, Sys #19 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #20 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #21 S

0 0.1

-0.1

-0.3 NO North Trench, Columns 16 to 18, Floor, Sys #22 S

0 0.1

-0.1

-0.3 NO Mean 2.1 Median

-0.3 Minimum

-0.3 Maximum 13.8 Std Dev (1s) 3.8 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO 0.4

-0.4

-1.1 NO Mean

-1.1 Median

-1.1 Minimum

-1.1 Maximum

-1.1 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw North Trench, Columns 16 to 18, Floor, Sys #1 S

52 53.8

-1.8

-6.7 NO North Trench, Columns 16 to 18, Floor, Sys #2 S

60 53.8 6.2 23.0 NO North Trench, Columns 16 to 18, Floor, Sys #3 S

57 53.8 3.2 11.9 NO North Trench, Columns 16 to 18, Floor, Sys #4 S

50 53.8

-3.8

-14.1 NO North Trench, Columns 16 to 18, Floor, Sys #5 S

49 53.8

-4.8

-17.8 NO North Trench, Columns 16 to 18, Floor, Sys #6 S

56 53.8 2.2 8.2 NO North Trench, Columns 16 to 18, Floor, Sys #7 S

61 53.8 7.2 26.8 NO North Trench, Columns 16 to 18, Floor, Sys #8 S

55 53.8 1.2 4.5 NO North Trench, Columns 16 to 18, Floor, Sys #9 S

54 53.8 0.2 0.7 NO North Trench, Columns 16 to 18, Floor, Sys #10 S

50 53.8

-3.8

-14.1 NO North Trench, Columns 16 to 18, Floor, Sys #11 S

44 53.8

-9.8

-36.4 NO North Trench, Columns 16 to 18, Floor, Sys #12 S

65 53.8 11.2 41.6 NO North Trench, Columns 16 to 18, Floor, Sys #13 S

50 53.8

-3.8

-14.1 NO North Trench, Columns 16 to 18, Floor, Sys #14 S

59 53.8 5.2 19.3 NO North Trench, Columns 16 to 18, Floor, Sys #15 S

52 53.8

-1.8

-6.7 NO North Trench, Columns 16 to 18, Floor, Sys #16 S

50 53.8

-3.8

-14.1 NO North Trench, Columns 16 to 18, Floor, Sys #17 S

51 53.8

-2.8

-10.4 NO North Trench, Columns 16 to 18, Floor, Sys #18 S

53 53.8

-0.8

-3.0 NO North Trench, Columns 16 to 18, Floor, Sys #19 S

69 53.8 15.2 56.5 NO North Trench, Columns 16 to 18, Floor, Sys #20 S

66 53.8 12.2 45.3 NO North Trench, Columns 16 to 18, Floor, Sys #21 S

52 53.8

-1.8

-6.7 NO North Trench, Columns 16 to 18, Floor, Sys #22 S

47 53.8

-6.8

-25.3 NO Mean 3.1 Median

-3.0 Minimum

-36.4 Maximum 56.5 Std Dev (1s) 23.8 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO 51.2

-51.2

-190.2 NO Mean

-190.2 Median

-190.2 Minimum

-190.2 Maximum

-190.2 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.357 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw LateralTrench, Section 6W-1, West Wall, Sys #1 S

1 0.4 0.6 1.7 NO LateralTrench, Section 6W-1, West Wall, Sys #2 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #3 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #4 S

3 0.4 2.6 7.3 NO LateralTrench, Section 6W-1, West Wall, Sys #5 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #6 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #7 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #8 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #9 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #10 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, West Wall, Sys #11 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #12 S

2 0.4 1.6 4.5 NO LateralTrench, Section 6W-1, East Wall, Sys #13 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #14 S

1 0.4 0.6 1.7 NO LateralTrench, Section 6W-1, East Wall, Sys #15 S

3 0.4 2.6 7.3 NO LateralTrench, Section 6W-1, East Wall, Sys #16 S

1 0.4 0.6 1.7 NO LateralTrench, Section 6W-1, East Wall, Sys #17 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #18 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #19 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #20 S

2 0.4 1.6 4.5 NO LateralTrench, Section 6W-1, East Wall, Sys #21 S

0 0.4

-0.4

-1.1 NO LateralTrench, Section 6W-1, East Wall, Sys #22 S

0 0.4

-0.4

-1.1 NO Mean 0.5 Median

-1.1 Minimum

-1.1 Maximum 7.3 Std Dev (1s) 2.8 ST, Section 6W-1, Wwall, Grid 3 Bottom Biased #1 B

1 0.4 0.6 1.7 NO ST, Section 6W-1, Wwall, Grid 10 Bottom Biased #2 B

0 0.4

-0.4

-1.1 NO ST, Section 6W-1, Ewall, Grid 10 Top Biased #3 B

0 0.4

-0.4

-1.1 NO ST, Section 6W-1, Ewall, Grid 30 Bottom Biased #4 B

0 0.4

-0.4

-1.1 NO Mean

-0.4 Median

-1.1 Minimum

-1.1 Maximum 1.7 Std Dev (1s)

1.4 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Lateral Trench Section 6 - Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.267 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw LateralTrench, Section 6W-1, West Wall, Sys #1 S

54 50.3 3.7 13.8 NO LateralTrench, Section 6W-1, West Wall, Sys #2 S

57 50.3 6.7 25.0 NO LateralTrench, Section 6W-1, West Wall, Sys #3 S

39 50.3

-11.3

-42.2 NO LateralTrench, Section 6W-1, West Wall, Sys #4 S

58 50.3 7.7 28.8 NO LateralTrench, Section 6W-1, West Wall, Sys #5 S

53 50.3 2.7 10.1 NO LateralTrench, Section 6W-1, West Wall, Sys #6 S

56 50.3 5.7 21.3 NO LateralTrench, Section 6W-1, West Wall, Sys #7 S

52 50.3 1.7 6.4 NO LateralTrench, Section 6W-1, West Wall, Sys #8 S

48 50.3

-2.3

-8.6 NO LateralTrench, Section 6W-1, West Wall, Sys #9 S

52 50.3 1.7 6.4 NO LateralTrench, Section 6W-1, West Wall, Sys #10 S

53 50.3 2.7 10.1 NO LateralTrench, Section 6W-1, West Wall, Sys #11 S

58 50.3 7.7 28.8 NO LateralTrench, Section 6W-1, East Wall, Sys #12 S

54 50.3 3.7 13.8 NO LateralTrench, Section 6W-1, East Wall, Sys #13 S

54 50.3 3.7 13.8 NO LateralTrench, Section 6W-1, East Wall, Sys #14 S

57 50.3 6.7 25.0 NO LateralTrench, Section 6W-1, East Wall, Sys #15 S

49 50.3

-1.3

-4.9 NO LateralTrench, Section 6W-1, East Wall, Sys #16 S

53 50.3 2.7 10.1 NO LateralTrench, Section 6W-1, East Wall, Sys #17 S

45 50.3

-5.3

-19.8 NO LateralTrench, Section 6W-1, East Wall, Sys #18 S

51 50.3 0.7 2.6 NO LateralTrench, Section 6W-1, East Wall, Sys #19 S

70 50.3 19.7 73.7 NO LateralTrench, Section 6W-1, East Wall, Sys #20 S

52 50.3 1.7 6.4 NO LateralTrench, Section 6W-1, East Wall, Sys #21 S

51 50.3 0.7 2.6 NO LateralTrench, Section 6W-1, East Wall, Sys #22 S

56 50.3 5.7 21.3 NO Mean 11.1 Median 10.1 Minimum

-42.2 Maximum 73.7 Std Dev (1s) 21.6 ST, Section 6W-1, Wwall, Grid 3 Bottom Biased #1 B

63 50.3 12.7 47.5 NO ST, Section 6W-1, Wwall, Grid 10 Bottom Biased #2 B

57 50.3 6.7 25.0 NO ST, Section 6W-1, Ewall, Grid 10 Top Biased #3 B

54 50.3 3.7 13.8 NO ST, Section 6W-1, Ewall, Grid 30 Bottom Biased #4 B

44 50.3

-6.3

-23.6 NO Mean 15.7 Median 19.4 Minimum

-23.6 Maximum 47.5 Std Dev (1s) 29.7 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Lateral Trench Section 6 - Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.357 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw North Trench, Columns 16 to 18, North Wall, Sys #1 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #2 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #3 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #4 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #5 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #6 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, North Wall, Sys #7 S

1 0.4 0.6 1.7 NO North Trench, Columns 16 to 18, North Wall, Sys #8 S

2 0.4 1.6 4.5 NO North Trench, Columns 16 to 18, South Wall, Sys #9 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, South Wall, Sys #10 S

1 0.4 0.6 1.7 NO North Trench, Columns 16 to 18, South Wall, Sys #11 S

1 0.4 0.6 1.7 NO North Trench, Columns 16 to 18, South Wall, Sys #12 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, South Wall, Sys #13 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, South Wall, Sys #14 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, South Wall, Sys #15 S

3 0.4 2.6 7.3 NO North Trench, Columns 16 to 18, South Wall, Sys #16 S

1 0.4 0.6 1.7 NO North Trench, Columns 16 to 18, West Wall, Sys #17 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, West Wall, Sys #18 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, West Wall, Sys #19 S

1 0.4 0.6 1.7 NO North Trench, Columns 16 to 18, East Wall, Sys #20 S

0 0.4

-0.4

-1.1 NO North Trench, Columns 16 to 18, East Wall, Sys #21 S

2 0.4 1.6 4.5 NO North Trench, Columns 16 to 18, East Wall, Sys #22 S

1 0.4 0.6 1.7 NO Mean 0.5 Median

-1.1 Minimum

-1.1 Maximum 7.3 Std Dev (1s)

2.4 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.267 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw North Trench, Columns 16 to 18, North Wall, Sys #1 S

41 50.3

-9.3

-34.8 NO North Trench, Columns 16 to 18, North Wall, Sys #2 S

53 50.3 2.7 10.1 NO North Trench, Columns 16 to 18, North Wall, Sys #3 S

57 50.3 6.7 25.0 NO North Trench, Columns 16 to 18, North Wall, Sys #4 S

49 50.3

-1.3

-4.9 NO North Trench, Columns 16 to 18, North Wall, Sys #5 S

55 50.3 4.7 17.6 NO North Trench, Columns 16 to 18, North Wall, Sys #6 S

71 50.3 20.7 77.4 NO North Trench, Columns 16 to 18, North Wall, Sys #7 S

53 50.3 2.7 10.1 NO North Trench, Columns 16 to 18, North Wall, Sys #8 S

49 50.3

-1.3

-4.9 NO North Trench, Columns 16 to 18, South Wall, Sys #9 S

63 50.3 12.7 47.5 NO North Trench, Columns 16 to 18, South Wall, Sys #10 S

57 50.3 6.7 25.0 NO North Trench, Columns 16 to 18, South Wall, Sys #11 S

55 50.3 4.7 17.6 NO North Trench, Columns 16 to 18, South Wall, Sys #12 S

55 50.3 4.7 17.6 NO North Trench, Columns 16 to 18, South Wall, Sys #13 S

48 50.3

-2.3

-8.6 NO North Trench, Columns 16 to 18, South Wall, Sys #14 S

52 50.3 1.7 6.4 NO North Trench, Columns 16 to 18, South Wall, Sys #15 S

64 50.3 13.7 51.2 NO North Trench, Columns 16 to 18, South Wall, Sys #16 S

60 50.3 9.7 36.3 NO North Trench, Columns 16 to 18, West Wall, Sys #17 S

49 50.3

-1.3

-4.9 NO North Trench, Columns 16 to 18, West Wall, Sys #18 S

62 50.3 11.7 43.7 NO North Trench, Columns 16 to 18, West Wall, Sys #19 S

66 50.3 15.7 58.7 NO North Trench, Columns 16 to 18, East Wall, Sys #20 S

45 50.3

-5.3

-19.8 NO North Trench, Columns 16 to 18, East Wall, Sys #21 S

53 50.3 2.7 10.1 NO North Trench, Columns 16 to 18, East Wall, Sys #22 S

70 50.3 19.7 73.7 NO Mean 20.5 Median 17.6 Minimum

-34.8 Maximum 77.4 Std Dev (1s) 29.3 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Floor Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw NorthTrench, SU 6FW-1, Syst #1, Floor, Grid #2 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #2, North Wall, Grid #12 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #3, South Wall, Grid #12 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #4, Floor, Grid #14 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #5, North Wall, Grid #24 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #6, South Wall, Grid #25 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #7, Floor, Grid #26 S

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Syst #8, North Wall, Grid #36 S

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Syst #9, South Wall, Grid #37 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #10, Floor, Grid #38 S

2 0.1 1.9 5.3 NO NorthTrench, SU 6FW-1, Syst #11, North Wall, Grid #48 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #12, South Wall, Grid #49 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #13, Floor, Grid #50 S

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Syst #14, North Wall, Grid #60 S

2 0.1 1.9 5.3 NO NorthTrench, SU 6FW-1, Syst #15, South Wall, Grid #61 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #16, Floor, Grid #62 S

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Syst #17, North Wall, Grid #72 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #18, South Wall, Grid #73 S

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Syst #19, Floor, Grid #74 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #20, North Wall, Grid #84 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #21, South Wall, Grid #85 S

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Syst #22, Floor, Grid #86 S

0 0.1

-0.1

-0.3 NO Mean 0.9 Median

-0.3 Minimum

-0.3 Maximum 5.3 Std Dev (1s) 1.9 NorthTrench, SU 6FW-1, Wall Grid 16 Top, Biased #1 B

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Wall Grid 50 Bottom, Biased #2 B

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Wall Grid 83 Top, Biased #3 B

2 0.1 1.9 5.3 NO NorthTrench, SU 6FW-1, Wall Grid 43 Bottom, Biased #4 B

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Wall Grid 87 Bottom, Biased #5 B

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Wall Grid 16 Bottom, Biased #6 B

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Wall Grid 21 Bottom, Biased #7 B

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Wall Grid 31 Top, Biased #8 B

1 0.1 0.9 2.5 NO NorthTrench, SU 6FW-1, Wall Grid 31 Bottom, Biased #9 B

0 0.1

-0.1

-0.3 NO NorthTrench, SU 6FW-1, Wall Grid 32 Bottom, Biased #10 B

0 0.1

-0.1

-0.3 NO Mean 1.4 Median 1.1 Minimum

-0.3 Maximum 5.3 Std Dev (1s)

2.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor/Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Floor Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw NorthTrench, SU 6FW-1, Syst #1, Floor, Grid #2 S

45 51.1

-6.1

-22.7 NO NorthTrench, SU 6FW-1, Syst #2, North Wall, Grid #12 S

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-1, Syst #3, South Wall, Grid #12 S

51 51.1

-0.1

-0.4 NO NorthTrench, SU 6FW-1, Syst #4, Floor, Grid #14 S

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-1, Syst #5, North Wall, Grid #24 S

60 51.1 8.9 33.1 NO NorthTrench, SU 6FW-1, Syst #6, South Wall, Grid #25 S

58 51.1 6.9 25.6 NO NorthTrench, SU 6FW-1, Syst #7, Floor, Grid #26 S

55 51.1 3.9 14.5 NO NorthTrench, SU 6FW-1, Syst #8, North Wall, Grid #36 S

61 51.1 9.9 36.8 NO NorthTrench, SU 6FW-1, Syst #9, South Wall, Grid #37 S

46 51.1

-5.1

-18.9 NO NorthTrench, SU 6FW-1, Syst #10, Floor, Grid #38 S

48 51.1

-3.1

-11.5 NO NorthTrench, SU 6FW-1, Syst #11, North Wall, Grid #48 S

43 51.1

-8.1

-30.1 NO NorthTrench, SU 6FW-1, Syst #12, South Wall, Grid #49 S

44 51.1

-7.1

-26.4 NO NorthTrench, SU 6FW-1, Syst #13, Floor, Grid #50 S

45 51.1

-6.1

-22.7 NO NorthTrench, SU 6FW-1, Syst #14, North Wall, Grid #60 S

47 51.1

-4.1

-15.2 NO NorthTrench, SU 6FW-1, Syst #15, South Wall, Grid #61 S

46 51.1

-5.1

-18.9 NO NorthTrench, SU 6FW-1, Syst #16, Floor, Grid #62 S

52 51.1 0.9 3.3 NO NorthTrench, SU 6FW-1, Syst #17, North Wall, Grid #72 S

56 51.1 4.9 18.2 NO NorthTrench, SU 6FW-1, Syst #18, South Wall, Grid #73 S

58 51.1 6.9 25.6 NO NorthTrench, SU 6FW-1, Syst #19, Floor, Grid #74 S

43 51.1

-8.1

-30.1 NO NorthTrench, SU 6FW-1, Syst #20, North Wall, Grid #84 S

67 51.1 15.9 59.1 NO NorthTrench, SU 6FW-1, Syst #21, South Wall, Grid #85 S

53 51.1 1.9 7.1 NO NorthTrench, SU 6FW-1, Syst #22, Floor, Grid #86 S

52 51.1 0.9 3.3 NO Mean 1.0 Median

-0.4 Minimum

-30.1 Maximum 59.1 Std Dev (1s) 24.4 NorthTrench, SU 6FW-1, Wall Grid 16 Top, Biased #1 B

52 51.1 0.9 3.3 NO NorthTrench, SU 6FW-1, Wall Grid 50 Bottom, Biased #2 B

54 51.1 2.9 10.8 NO NorthTrench, SU 6FW-1, Wall Grid 83 Top, Biased #3 B

53 51.1 1.9 7.1 NO NorthTrench, SU 6FW-1, Wall Grid 43 Bottom, Biased #4 B

46 51.1

-5.1

-18.9 NO NorthTrench, SU 6FW-1, Wall Grid 87 Bottom, Biased #5 B

61 51.1 9.9 36.8 NO NorthTrench, SU 6FW-1, Wall Grid 16 Bottom, Biased #6 B

62 51.1 10.9 40.5 NO NorthTrench, SU 6FW-1, Wall Grid 21 Bottom, Biased #7 B

49 51.1

-2.1

-7.8 NO NorthTrench, SU 6FW-1, Wall Grid 31 Top, Biased #8 B

51 51.1

-0.1

-0.4 NO NorthTrench, SU 6FW-1, Wall Grid 31 Bottom, Biased #9 B

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-1, Wall Grid 32 Bottom, Biased #10 B

63 51.1 11.9 44.2 NO Mean 11.1 Median 5.2 Minimum

-18.9 Maximum 44.2 Std Dev (1s) 21.9 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor/Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Concrete Walls Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw NorthTrench, SU 6FW-2, Syst #1, Floor, Grid #6 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #2, North Wall, Grid #7 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #3, South Wall, Grid #8 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #4, Floor, Grid #14 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #5, North Wall, Grid #15 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #6, South Wall, Grid #16 S

2 0.2 1.8 5.1 NO NorthTrench, SU 6FW-2, Syst #7, Floor, Grid #22 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #8, North Wall, Grid #23 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #9, South Wall, Grid #24 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #10, Floor, Grid #30 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #11, North Wall, Grid #31 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #12, South Wall, Grid #32 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #13, Floor, Grid #38 S

2 0.2 1.8 5.1 NO NorthTrench, SU 6FW-2, Syst #14, North Wall, Grid #39 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #15, South Wall, Grid #40 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #16, Floor, Grid #46 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #17, North Wall, Grid #47 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #18, South Wall, Grid #48 S

1 0.2 0.8 2.2 NO NorthTrench, SU 6FW-2, Syst #19, Floor, Grid #54 S

2 0.2 1.8 5.1 NO NorthTrench, SU 6FW-2, Syst #20, North Wall, Grid #55 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #21, South Wall, Grid #56 S

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, Syst #22, Floor, Grid #62 S

0 0.2

-0.2

-0.6 NO Mean 1.0 Median

-0.6 Minimum

-0.6 Maximum 5.1 Std Dev (1s) 2.1 NorthTrench, SU 6FW-2, North Wall Grid 30 Bottom, Bias #1 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, North Wall Grid 41 Bottom, Bias #2 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, North Wall Grid 61 Bottom, Bias #3 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, South Wall Grid 28 Bottom, Bias #4 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, South Wall Grid 60 Bottom, Bias #5 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, North Floor Grid 43, Bias #6 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, North Floor Grid 45, Bias #7 B

0 0.2

-0.2

-0.6 NO NorthTrench, SU 6FW-2, South Floor Grid 48, Bias #8 B

0 0.2

-0.2

-0.6 NO Mean

-0.6 Median

-0.6 Minimum

-0.6 Maximum

-0.6 Std Dev (1s)

0.0 NOTES

1 Instrument Efficiency = Instrument 4-pi efficiency for alpha 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor/Wall Survey Unit - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Concrete Walls Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw NorthTrench, SU 6FW-2, Syst #1, Floor, Grid #6 S

61 51.1 9.9 36.8 NO NorthTrench, SU 6FW-2, Syst #2, North Wall, Grid #7 S

53 51.1 1.9 7.1 NO NorthTrench, SU 6FW-2, Syst #3, South Wall, Grid #8 S

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-2, Syst #4, Floor, Grid #14 S

58 51.1 6.9 25.6 NO NorthTrench, SU 6FW-2, Syst #5, North Wall, Grid #15 S

57 51.1 5.9 21.9 NO NorthTrench, SU 6FW-2, Syst #6, South Wall, Grid #16 S

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-2, Syst #7, Floor, Grid #22 S

51 51.1

-0.1

-0.4 NO NorthTrench, SU 6FW-2, Syst #8, North Wall, Grid #23 S

49 51.1

-2.1

-7.8 NO NorthTrench, SU 6FW-2, Syst #9, South Wall, Grid #24 S

65 51.1 13.9 51.6 NO NorthTrench, SU 6FW-2, Syst #10, Floor, Grid #30 S

47 51.1

-4.1

-15.2 NO NorthTrench, SU 6FW-2, Syst #11, North Wall, Grid #31 S

63 51.1 11.9 44.2 NO NorthTrench, SU 6FW-2, Syst #12, South Wall, Grid #32 S

48 51.1

-3.1

-11.5 NO NorthTrench, SU 6FW-2, Syst #13, Floor, Grid #38 S

55 51.1 3.9 14.5 NO NorthTrench, SU 6FW-2, Syst #14, North Wall, Grid #39 S

52 51.1 0.9 3.3 NO NorthTrench, SU 6FW-2, Syst #15, South Wall, Grid #40 S

64 51.1 12.9 47.9 NO NorthTrench, SU 6FW-2, Syst #16, Floor, Grid #46 S

46 51.1

-5.1

-18.9 NO NorthTrench, SU 6FW-2, Syst #17, North Wall, Grid #47 S

51 51.1

-0.1

-0.4 NO NorthTrench, SU 6FW-2, Syst #18, South Wall, Grid #48 S

53 51.1 1.9 7.1 NO NorthTrench, SU 6FW-2, Syst #19, Floor, Grid #54 S

51 51.1

-0.1

-0.4 NO NorthTrench, SU 6FW-2, Syst #20, North Wall, Grid #55 S

55 51.1 3.9 14.5 NO NorthTrench, SU 6FW-2, Syst #21, South Wall, Grid #56 S

60 51.1 8.9 33.1 NO NorthTrench, SU 6FW-2, Syst #22, Floor, Grid #62 S

57 51.1 5.9 21.9 NO Mean 12.1 Median 7.1 Minimum

-18.9 Maximum 51.6 Std Dev (1s) 20.8 NorthTrench, SU 6FW-2, North Wall Grid 30 Bottom, Bias #1 B

48 51.1

-3.1

-11.5 NO NorthTrench, SU 6FW-2, North Wall Grid 41 Bottom, Bias #2 B

57 51.1 5.9 21.9 NO NorthTrench, SU 6FW-2, North Wall Grid 61 Bottom, Bias #3 B

64 51.1 12.9 47.9 NO NorthTrench, SU 6FW-2, South Wall Grid 28 Bottom, Bias #4 B

59 51.1 7.9 29.4 NO NorthTrench, SU 6FW-2, South Wall Grid 60 Bottom, Bias #5 B

54 51.1 2.9 10.8 NO NorthTrench, SU 6FW-2, North Floor Grid 43, Bias #6 B

50 51.1

-1.1

-4.1 NO NorthTrench, SU 6FW-2, North Floor Grid 45, Bias #7 B

44 51.1

-7.1

-26.4 NO NorthTrench, SU 6FW-2, South Floor Grid 48, Bias #8 B

55 51.1 3.9 14.5 NO Mean 10.3 Median 12.6 Minimum

-26.4 Maximum 47.9 Std Dev (1s) 23.8 NOTES:

1 Instrument Efficiency = Instrument 4-pi efficiency for beta 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute North Trench Section 6 - Floor/Wall Survey Unit - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Pipe Internals Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 6:00 #1 S

3 0.2 2.8 7.9 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 9:00 #2 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 12:00 #3 S

5 0.2 4.8 13.5 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 3:00 #4 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 6:00 #5 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 9:00 #6 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 12:00 #7 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 3:00 #8 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 6:00 #9 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 9:00 #10 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 12:00 #11 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 3:00 #12 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 6:00 #13 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 9:00 #14 S

1 0.2 0.8 2.2 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 12:00 #15 S

0 0.2

-0.2

-0.6 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 3:00 #16 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 6:00 #1 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 9:00 #2 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 12:00 #3 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 3:00 #4 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 6:00 #5 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 9:00 #6 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 12:00 #7 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 3:00 #8 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 6:00 #9 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 9:00 #10 S

1 0.2 0.8 2.2 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 12:00 #11 S

0 0.2

-0.2

-0.6 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 3:00 #12 S

0 0.2

-0.2

-0.6 NO Mean 1.4 Median

-0.6 Minimum

-0.6 Maximum 13.5 Std Dev (1s)

3.0 NOTES

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Shelton Avenue Abandoned Sewer Pipe - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Pipe Internals Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 6:00 #1 S

61 49.5 11.5 42.7 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 9:00 #2 S

52 49.5 2.5 9.3 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 12:00 #3 S

44 49.5

-5.5

-20.4 NO Eastern End of Sewer Pipe in Shelton Ave, 0 ft, 3:00 #4 S

47 49.5

-2.5

-9.3 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 6:00 #5 S

42 49.5

-7.5

-27.9 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 9:00 #6 S

41 49.5

-8.5

-31.6 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 12:00 #7 S

54 49.5 4.5 16.7 NO Eastern End of Sewer Pipe in Shelton Ave, 1 ft, 3:00 #8 S

65 49.5 15.5 57.6 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 6:00 #9 S

57 49.5 7.5 27.9 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 9:00 #10 S

43 49.5

-6.5

-24.2 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 12:00 #11 S

54 49.5 4.5 16.7 NO Eastern End of Sewer Pipe in Shelton Ave, 2 ft, 3:00 #12 S

55 49.5 5.5 20.4 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 6:00 #13 S

43 49.5

-6.5

-24.2 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 9:00 #14 S

47 49.5

-2.5

-9.3 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 12:00 #15 S

51 49.5 1.5 5.6 NO Eastern End of Sewer Pipe in Shelton Ave, 3 ft, 3:00 #16 S

47 49.5

-2.5

-9.3 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 6:00 #1 S

52 45.6 6.4 23.8 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 9:00 #2 S

52 45.6 6.4 23.8 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 12:00 #3 S

49 45.6 3.4 12.6 NO Western End of Sewer Pipe in Shelton Ave, 0 ft, 3:00 #4 S

42 45.6

-3.6

-13.4 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 6:00 #5 S

41 45.6

-4.6

-17.1 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 9:00 #6 S

48 45.6 2.4 8.9 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 12:00 #7 S

42 45.6

-3.6

-13.4 NO Western End of Sewer Pipe in Shelton Ave, 1 ft, 3:00 #8 S

49 45.6 3.4 12.6 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 6:00 #9 S

55 45.6 9.4 34.9 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 9:00 #10 S

45 45.6

-0.6

-2.2 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 12:00 #11 S

57 45.6 11.4 42.4 NO Western End of Sewer Pipe in Shelton Ave, 2 ft, 3:00 #12 S

44 45.6

-1.6

-5.9 NO Mean 5.3 Median 5.6 Minimum

-31.6 Maximum 57.6 Std Dev (1s) 23.6 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute Shelton Avenue Abandoned Sewer Pipe - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Pipe Internals Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Decon Pit, Pipe Chase, Floor 1 #1 B

4 0.2 3.8 10.7 NO Decon Pit, Pipe Chase, Floor 2 #2 B

0 0.2

-0.2

-0.6 NO Decon Pit, Pipe Chase, Floor 3 #3 B

1 0.2 0.8 2.2 NO Decon Pit, Pipe Chase, Floor 4 #4 B

2 0.2 1.8 5.1 NO Decon Pit, Pipe Chase, Nwall Top 1 #15 B

0 0.2

-0.2

-0.6 NO Decon Pit, Pipe Chase, Nwall Top 2 #16 B

0 0.2

-0.2

-0.6 NO Decon Pit, Pipe Chase, Nwall 1 #9 B

0 0.2

-0.2

-0.6 NO Decon Pit, Pipe Chase, Nwall 2 #10 B

1 0.2 0.8 2.2 NO Decon Pit, Pipe Chase, Nwall 3 #11 B

3 0.2 2.8 7.9 NO Decon Pit, Pipe Chase, Nwall 4 #12 B

1 0.2 0.8 2.2 NO Decon Pit, Pipe Chase, Swall 1 #5 B

1 0.2 0.8 2.2 NO Decon Pit, Pipe Chase, Swall 2#6 B

0 0.2

-0.2

-0.6 NO Decon Pit, Pipe Chase, Swall 3 #7 B

1 0.2 0.8 2.2 NO Decon Pit, Pipe Chase, Swall 4 #8 B

2 0.2 1.8 5.1 NO Decon Pit, Pipe Chase, Swall Top 1 #13 B

2 0.2 1.8 5.1 NO Decon Pit, Pipe Chase, Swall Top 2 #14 B

4 0.2 3.8 10.7 NO Decon Pit Excavation South Wall Grid #1 B

1 0.3 0.7 2.0 NO Decon Pit Excavation South Wall Grid #2 B

2 0.3 1.7 4.8 NO Decon Pit Excavation South Wall Grid #3 B

0 0.3

-0.3

-0.8 NO Decon Pit Excavation South Wall Grid #4 B

1 0.3 0.7 2.0 NO Decon Pit Excavation South Wall Grid #5 B

0 0.3

-0.3

-0.8 NO Decon Pit Excavation South Wall Grid #6 B

0 0.3

-0.3

-0.8 NO Decon Pit Excavation South Wall Grid #7 B

0 0.3

-0.3

-0.8 NO Decon Pit Excavation South Wall Grid #8 B

1 0.3 0.7 2.0 NO Decon Pit Excavation South Wall Grid #9 B

0 0.3

-0.3

-0.8 NO Decon Pit Excavation South Wall Grid #10 B

0 0.3

-0.3

-0.8 NO Mean 2.2 Median 2.0 Minimum

-0.8 Maximum 10.7 Std Dev (1s)

3.5 NOTES

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Decon Pit Structure Surfaces - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Pipe Internals Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Decon Pit, Pipe Chase, Floor 1 #1 B

55 47.6 7.4 27.5 NO Decon Pit, Pipe Chase, Floor 2 #2 B

48 47.6 0.4 1.5 NO Decon Pit, Pipe Chase, Floor 3 #3 B

61 47.6 13.4 49.8 NO Decon Pit, Pipe Chase, Floor 4 #4 B

56 47.6 8.4 31.2 NO Decon Pit, Pipe Chase, Nwall Top 1 #15 B

55 47.6 7.4 27.5 NO Decon Pit, Pipe Chase, Nwall Top 2 #16 B

42 47.6

-5.6

-20.8 NO Decon Pit, Pipe Chase, Nwall 1 #9 B

50 47.6 2.4 8.9 NO Decon Pit, Pipe Chase, Nwall 2 #10 B

41 47.6

-6.6

-24.5 NO Decon Pit, Pipe Chase, Nwall 3 #11 B

47 47.6

-0.6

-2.2 NO Decon Pit, Pipe Chase, Nwall 4 #12 B

35 47.6

-12.6

-46.8 NO Decon Pit, Pipe Chase, Swall 1 #5 B

53 47.6 5.4 20.1 NO Decon Pit, Pipe Chase, Swall 2#6 B

39 47.6

-8.6

-32.0 NO Decon Pit, Pipe Chase, Swall 3 #7 B

49 47.6 1.4 5.2 NO Decon Pit, Pipe Chase, Swall 4 #8 B

71 47.6 23.4 86.9 NO Decon Pit, Pipe Chase, Swall Top 1 #13 B

50 47.6 2.4 8.9 NO Decon Pit, Pipe Chase, Swall Top 2 #14 B

45 47.6

-2.6

-9.7 NO Decon Pit Excavation South Wall Grid #1 B

45 48.6

-3.6

-13.4 NO Decon Pit Excavation South Wall Grid #2 B

64 48.6 15.4 57.2 NO Decon Pit Excavation South Wall Grid #3 B

42 48.6

-6.6

-24.5 NO Decon Pit Excavation South Wall Grid #4 B

62 48.6 13.4 49.8 NO Decon Pit Excavation South Wall Grid #5 B

36 48.6

-12.6

-46.8 NO Decon Pit Excavation South Wall Grid #6 B

56 48.6 7.4 27.5 NO Decon Pit Excavation South Wall Grid #7 B

48 48.6

-0.6

-2.2 NO Decon Pit Excavation South Wall Grid #8 B

44 48.6

-4.6

-17.1 NO Decon Pit Excavation South Wall Grid #9 B

47 48.6

-1.6

-5.9 NO Decon Pit Excavation South Wall Grid #10 B

45 48.6

-3.6

-13.4 NO Mean 5.5 Median

-2.2 Minimum

-46.8 Maximum 86.9 Std Dev (1s) 32.7 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute Decon Pit Structure Surfaces - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Pipe Internals Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Decon Pit Floor East #1 B

10 0.3 9.7 27.2 NO Decon Pit Floor East #2 B

29 0.3 28.7 80.6 NO Decon Pit Floor East #3 B

0 0.3

-0.3

-0.8 NO Decon Pit Floor East #4 B

1 0.3 0.7 2.0 NO Decon Pit Floor East #5 B

5 0.3 4.7 13.2 NO Decon Pit Floor East #6 B

2 0.3 1.7 4.8 NO Decon Pit Floor East #7 B

6 0.3 5.7 16.0 NO Decon Pit Floor East #8 B

29 0.3 28.7 80.6 NO Decon Pit Floor East #9 B

15 0.3 14.7 41.3 NO Decon Pit Floor East #10 B

5 0.3 4.7 13.2 NO Decon Pit Floor East #11 B

2 0.3 1.7 4.8 NO Decon Pit Floor East #12 B

11 0.3 10.7 30.0 NO Decon Pit Floor East #13 B

9 0.3 8.7 24.4 NO Decon Pit Floor East #14 B

3 0.3 2.7 7.6 NO Decon Pit Floor East #15 B

1 0.3 0.7 2.0 NO Mean 23.1 Median 13.2 Minimum

-0.8 Maximum 80.6 Std Dev (1s) 26.2 NOTES:

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Decon Pit Room East Floor Surfaces - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Pipe Internals Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Decon Pit Floor East #1 B

64 49.3 14.7 54.6 NO Decon Pit Floor East #2 B

60 49.3 10.7 39.8 NO Decon Pit Floor East #3 B

58 49.3 8.7 32.3 NO Decon Pit Floor East #4 B

46 49.3

-3.3

-12.3 NO Decon Pit Floor East #5 B

60 49.3 10.7 39.8 NO Decon Pit Floor East #6 B

48 49.3

-1.3

-4.8 NO Decon Pit Floor East #7 B

66 49.3 16.7 62.0 NO Decon Pit Floor East #8 B

48 49.3

-1.3

-4.8 NO Decon Pit Floor East #9 B

47 49.3

-2.3

-8.5 NO Decon Pit Floor East #10 B

42 49.3

-7.3

-27.1 NO Decon Pit Floor East #11 B

47 49.3

-2.3

-8.5 NO Decon Pit Floor East #12 B

52 49.3 2.7 10.0 NO Decon Pit Floor East #13 B

54 49.3 4.7 17.5 NO Decon Pit Floor East #14 B

50 49.3 0.7 2.6 NO Decon Pit Floor East #15 B

64 49.3 14.7 54.6 NO Mean 16.5 Median 6.3 Minimum

-27.1 Maximum 62.0 Std Dev (1s) 28.6 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute Decon Pit Room East Floor Surfaces - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Pipe Internals Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Small Trench Btw C41 and C40 Grid #1 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #2 B

1 0.2 0.8 2.2 NO Small Trench Btw C41 and C40 Grid #3 B

1 0.2 0.8 2.2 NO Small Trench Btw C41 and C40 Grid #4 B

1 0.2 0.8 2.2 NO Small Trench Btw C41 and C40 Grid #5 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #6 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #7 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #8 B

1 0.2 0.8 2.2 NO Small Trench Btw C41 and C40 Grid #9 B

5 0.2 4.8 13.5 NO Small Trench Btw C41 and C40 Grid #10 B

1 0.2 0.8 2.2 NO Small Trench Btw C41 and C40 Grid #11 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #12 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C41 and C40 Grid #13 B

2 0.2 1.8 5.1 NO Small Trench Btw C40 and C39 Grid #14 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C40 and C39 Grid #15 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C40 and C39 Grid #16 B

2 0.2 1.8 5.1 NO Small Trench Btw C40 and C39 Grid #17 B

1 0.2 0.8 2.2 NO Small Trench Btw C40 and C39 Grid #18 B

1 0.2 0.8 2.2 NO Small Trench Btw C40 and C39 Grid #19 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C40 and C39 Grid #20 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C40 and C39 Grid #21 B

3 0.2 2.8 7.9 NO Small Trench Btw C40 and C39 Grid #22 B

1 0.2 0.8 2.2 NO Small Trench Btw C40 and C39 Grid #23 B

2 0.2 1.8 5.1 NO Small Trench Btw C40 and C39 Grid #24 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C40 and C39 Grid #25 B

0 0.2

-0.2

-0.6 NO Small Trench Btw C39 and C38 Grid #26 B

2 0.2 1.8 5.1 NO Small Trench Btw C39 and C38 Grid #27 B

4 0.2 3.8 10.7 NO Small Trench Btw C39 and C38 Grid #28 B

6 0.2 5.8 16.3 NO Small Trench Btw C39 and C38 Grid #29 B

3 0.2 2.8 7.9 NO Small Trench Btw C39 and C38 Grid #30 B

4 0.2 3.8 10.7 NO Small Trench Btw C39 and C38 Grid #31 B

1 0.2 0.8 2.2 NO Small Trench Btw C39 and C38 Grid #32 B

6 0.2 5.8 16.3 NO Small Trench Btw C39 and C38 Grid #33 B

3 0.2 2.8 7.9 NO Small Trench Btw C39 and C38 Grid #34 B

4 0.2 3.8 10.7 NO Mean 4.0 Median 2.2 Minimum

-0.6 Maximum 16.3 Std Dev (1s)

5.1 NOTES

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Small Trench Surfaces - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Pipe Internals Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Small Trench Btw C41 and C40 Grid #1 B

60 50.6 9.4 34.9 NO Small Trench Btw C41 and C40 Grid #2 B

63 50.6 12.4 46.1 NO Small Trench Btw C41 and C40 Grid #3 B

54 50.6 3.4 12.6 NO Small Trench Btw C41 and C40 Grid #4 B

51 50.6 0.4 1.5 NO Small Trench Btw C41 and C40 Grid #5 B

65 50.6 14.4 53.5 NO Small Trench Btw C41 and C40 Grid #6 B

58 50.6 7.4 27.5 NO Small Trench Btw C41 and C40 Grid #7 B

45 50.6

-5.6

-20.8 NO Small Trench Btw C41 and C40 Grid #8 B

55 50.6 4.4 16.3 NO Small Trench Btw C41 and C40 Grid #9 B

40 50.6

-10.6

-39.4 NO Small Trench Btw C41 and C40 Grid #10 B

57 50.6 6.4 23.8 NO Small Trench Btw C41 and C40 Grid #11 B

47 50.6

-3.6

-13.4 NO Small Trench Btw C41 and C40 Grid #12 B

51 50.6 0.4 1.5 NO Small Trench Btw C41 and C40 Grid #13 B

55 50.6 4.4 16.3 NO Small Trench Btw C40 and C39 Grid #14 B

50 50.6

-0.6

-2.2 NO Small Trench Btw C40 and C39 Grid #15 B

46 50.6

-4.6

-17.1 NO Small Trench Btw C40 and C39 Grid #16 B

54 50.6 3.4 12.6 NO Small Trench Btw C40 and C39 Grid #17 B

51 50.6 0.4 1.5 NO Small Trench Btw C40 and C39 Grid #18 B

63 50.6 12.4 46.1 NO Small Trench Btw C40 and C39 Grid #19 B

56 50.6 5.4 20.1 NO Small Trench Btw C40 and C39 Grid #20 B

47 50.6

-3.6

-13.4 NO Small Trench Btw C40 and C39 Grid #21 B

50 50.6

-0.6

-2.2 NO Small Trench Btw C40 and C39 Grid #22 B

48 50.6

-2.6

-9.7 NO Small Trench Btw C40 and C39 Grid #23 B

59 50.6 8.4 31.2 NO Small Trench Btw C40 and C39 Grid #24 B

56 50.6 5.4 20.1 NO Small Trench Btw C40 and C39 Grid #25 B

62 50.6 11.4 42.4 NO Small Trench Btw C39 and C38 Grid #26 B

42 50.6

-8.6

-32.0 NO Small Trench Btw C39 and C38 Grid #27 B

57 50.6 6.4 23.8 NO Small Trench Btw C39 and C38 Grid #28 B

58 50.6 7.4 27.5 NO Small Trench Btw C39 and C38 Grid #29 B

71 50.6 20.4 75.8 NO Small Trench Btw C39 and C38 Grid #30 B

45 50.6

-5.6

-20.8 NO Small Trench Btw C39 and C38 Grid #31 B

56 50.6 5.4 20.1 NO Small Trench Btw C39 and C38 Grid #32 B

42 50.6

-8.6

-32.0 NO Small Trench Btw C39 and C38 Grid #33 B

45 50.6

-5.6

-20.8 NO Small Trench Btw C39 and C38 Grid #34 B

64 50.6 13.4 49.8 NO Mean 11.2 Median 14.5 Minimum

-39.4 Maximum 75.8 Std Dev (1s) 27.7 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute Small Trench Surfaces - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.357 100 1

1000 Pipe Chase Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Pipe Chase South Wall #1 B

1 0.2 0.8 2.2 NO Pipe Chase South Wall #2 B

3 0.2 2.8 7.9 NO Pipe Chase South Wall #3 B

0 0.2

-0.2

-0.6 NO Pipe Chase South Wall #4 B

2 0.2 1.8 5.0 NO Pipe Chase Floor #1 B

33 0.2 32.8 91.9 NO Pipe Chase Floor #2 B

25 0.2 24.9 69.9 NO Pipe Chase Floor #3 B

3 0.2 2.8 8.0 NO Pipe Chase Floor #4 B

8 0.2 7.8 22.0 NO Pipe Chase North Wall #1 B

2 0.2 1.8 5.0 NO Pipe Chase North Wall #2 B

2 0.2 1.8 5.0 NO Pipe Chase North Wall #3 B

8 0.2 7.8 22.0 NO Pipe Chase North Wall #4 B

6 0.2 5.7 16.0 NO Mean 21.2 Median 8.0 Minimum

-0.6 Maximum 91.9 Std Dev (1s) 29.2 NOTES:

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute X-Ray Read Room Pipe Chase Surfaces - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.267 100 1

1000 Pipe Chase Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Pipe Chase South Wall #1 B

56 55.4 0.6 2.2 NO Pipe Chase South Wall #2 B

53 55.4

-2.4

-9.0 NO Pipe Chase South Wall #3 B

55 55.4

-0.4

-1.5 NO Pipe Chase South Wall #4 B

55 55.4

-0.4

-1.5 NO Pipe Chase Floor #1 B

59 54.5 4.6 17.2 NO Pipe Chase Floor #2 B

58 54.5 3.5 12.9 NO Pipe Chase Floor #3 B

62 54.5 7.6 28.4 NO Pipe Chase Floor #4 B

42 54.5

-12.4

-46.4 NO Pipe Chase North Wall #1 B

47 54.5

-7.6

-28.4 NO Pipe Chase North Wall #2 B

49 54.5

-5.5

-20.6 NO Pipe Chase North Wall #3 B

54 54.5

-0.5

-1.7 NO Pipe Chase North Wall #4 B

50 54.5

-4.6

-17.2 NO Mean

-5.5 Median

-1.7 Minimum

-46.4 Maximum 28.4 Std Dev (1s) 20.6 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute X-Ray Read Room Pipe Chase Surfaces - Beta Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Alpha Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.356 100 1

1000 Haul Rd asphalt Sample ID Measurement Type2 Alpha Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Alpha Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Haul Road #1 B

1 0.5 0.5 1.4 NO Haul Road #2 B

0 0.5

-0.5

-1.4 NO Haul Road #3 B

0 0.5

-0.5

-1.4 NO Haul Road #4 B

0 0.5

-0.5

-1.4 NO Haul Road #5 B

0 0.5

-0.5

-1.4 NO Haul Road #6 B

0 0.5

-0.5

-1.4 NO Haul Road #7 B

1 0.5 0.5 1.4 NO Haul Road #8 B

1 0.5 0.5 1.4 NO Haul Road #9 B

1 0.5 0.5 1.4 NO Haul Road #10 B

3 0.5 2.5 7.0 NO Haul Road #11 B

0 0.5

-0.5

-1.4 NO Haul Road #12 B

0 0.5

-0.5

-1.4 NO Haul Road #13 B

0 0.5

-0.5

-1.4 NO Mean 0.1 Median

-1.4 Minimum

-1.4 Maximum 7.0 Std Dev (1s)

2.5 NOTES

1 Daily 10-minute background count in counts per minute 2

Sample Type: S = Systematic B = Biased 3

Daily 10-minute background count in counts per minute Haul Road Area - Alpha Smear Measurement Results SU

Description:

Instrument/Probe Models Instrument S/N Probe S/N Beta Efficiency1 Smeared Area (cm2)

MARSSIM Class:

SU DCGLw (dpm/100cm2) 3030E/43-10-1 217611 PR232046 0.269 100 1

1000 Haul Rd asphalt Sample ID Measurement Type2 Beta Counts (gross cpm)

Background3 (cpm)

Net Fixed-Point Result (net cpm)

Beta Residual Surface Activity (dpm/100cm2)

Net Activity Exceeds DCGLw Haul Road #1 B

50 53.1

-3.1

-11.5 NO Haul Road #2 B

54 53.1 0.9 3.3 NO Haul Road #3 B

68 53.1 14.9 55.4 NO Haul Road #4 B

54 53.1 0.9 3.3 NO Haul Road #5 B

49 53.1

-4.1

-15.2 NO Haul Road #6 B

44 53.1

-9.1

-33.8 NO Haul Road #7 B

58 53.1 4.9 18.2 NO Haul Road #8 B

48 53.1

-5.1

-18.9 NO Haul Road #9 B

45 53.1

-8.1

-30.1 NO Haul Road #10 B

47 53.1

-6.1

-22.7 NO Haul Road #11 B

56 53.1 2.9 10.8 NO Haul Road #12 B

59 53.1 5.9 21.9 NO Haul Road #13 B

43 53.1

-10.1

-37.5 NO Mean

-4.4 Median

-5.9 Minimum

-37.5 Maximum 55.4 Std Dev (1s) 26.6 NOTES:

1 Daily 10-minute background count in counts per minute 2 Sample Type: S = Systematic B = Biased 3 Daily 10-minute background count in counts per minute Haul Road Area - Beta Smear Measurement Results SU

Description: