- G A M M A S P E C T R U M A N A L Y S I S *****
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2120\\W6H-IMC-212 Report Generated On : 4/19/2017 10:41:26 AM Sample Title : W6H-IMC-2120-S-P-5 Sample Description :
Sample Identification : 2120-S-P-5 Sample Type :
Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.500 keV Sample Size : 2.803E+002 grams Sample Taken On : 3/17/2017 12:00:00 AM Acquisition Started : 3/29/2017 12:02:34 PM Live Time : 1800.0 seconds Real Time : 1800.4 seconds Dead Time : 0.02 %
Energy Calibration Used Done On : 3/24/2017 Efficiency Calibration Used Done On : 4/19/2017 Efficiency ID : H-IMC-2120-S-P-5
Peak Analysis Report 4/19/2017 10:41:26 AM Page 1
- P E A K A N A L Y S I S R E P O R T *****
Detector Name: 8566 Sample
Title:
W6H-IMC-2120-S-P-5 Peak Analysis Performed on: 4/19/2017 10:41:22 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts F 1 182-191 186.16 46.74 0.63 5.91E+001 19.74 6.00E+001 M 2 295-313 299.67 75.13 0.74 8.03E+001 24.63 1.16E+002 m 3 295-313 308.31 77.29 0.75 9.01E+001 23.66 8.15E+001 F 4 737-749 742.37 185.87 0.93 4.97E+001 19.33 6.01E+001 F 5 949-959 953.22 238.61 0.98 1.13E+002 24.27 4.26E+001 F 6 1172-1184 1178.54 294.98 1.01 3.55E+001 14.74 2.34E+001 F 7 1399-1411 1405.67 351.79 1.06 3.13E+001 15.23 3.25E+001 F 8 2031-2049 2040.05 510.48 1.68 5.01E+001 17.28 3.33E+001 F 9 5825-5851 5837.68 1460.45 2.52 1.86E+002 25.72 1.20E+001 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Interference Corrected Activity Report 4/19/2017 10:41:26 AM Page 2
- N U C L I D E I D E N T I F I C A T I O N R E P O R T *****
Sample
Title:
W6H-IMC-2120-S-P-5 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL
.................... IDENTIFIED NUCLIDES....................
Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.990 1460.82* 10.66 1.17194E+001 1.90534E+000 Pb-210 0.997 46.54* 4.25 2.40496E+000 1.05363E+000 Pb-212 0.999 74.82* 10.28 6.74650E-001 2.47749E-001 77.11* 17.10 4.45515E-001 1.47454E-001 86.83 2.07 87.35 3.97 89.78 1.46 115.18 0.60 238.63* 43.60 3.03365E-001 8.11640E-002 300.09 3.30 PB-214 0.998 74.82* 5.80 1.19576E+000 4.51959E-001 77.11* 9.70 7.85393E-001 2.69390E-001 86.83 1.70 87.35 2.24 89.78 0.82 241.99 7.25 258.76 0.53 274.80 0.35 295.22* 18.42 2.78494E-001 1.23706E-001 351.93* 35.60 1.52879E-001 7.75970E-002 462.02 0.21 480.43 0.34 487.14 0.43 533.66 0.18 580.14 0.37 785.96 1.06 839.07 0.58 Ra-226 0.993 81.07 0.20 83.79 0.32 186.21* 3.64 1.29677E+000 5.50247E-001
- = Energy line found in the spectrum.
@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.500 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma
Interference Corrected Activity Report 4/19/2017 10:41:26 AM Page 3
- I N T E R F E R E N C E C O R R E C T E D R E P O R T *****
Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.990 1.171940E+001 1.905345E+000 Pb-210 0.997 2.404958E+000 1.053628E+000 Pb-212 0.999 3.296877E-001 6.880852E-002 PB-214 0.998 1.981613E-001 6.377990E-002 Ra-226 0.993 1.296774E+000 5.502469E-001
? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis
@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma
- U N I D E N T I F I E D P E A K S **********
Peak Locate Performed on: 4/19/2017 10:41:22 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.
No. (keV) Counts per Second % Uncertainty Type Nuclide F 8 510.48 2.7857E-002 34.47 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma
Nuclide MDA Report 4/19/2017 10:41:26 AM Page 4
- N U C L I D E M D A R E P O R T *****
Detector Name: 8566 Sample Geometry: cylinder Sample
Title:
W6H-IMC-2120-S-P-5 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ K-40 1460.82* 10.66 1.308E+000 1.31E+000 1.172E+001 5.687E-00 CO-60 1173.23 99.85 2.351E-001 1.79E-001 1.203E-001 1.100E-00 1332.49 99.98 1.787E-001 3.574E-002 8.090E-00 CS-137 661.66 85.10 1.651E-001 1.65E-001 3.215E-002 7.725E-00
+ Pb-210 46.54* 4.25 1.805E+000 1.80E+000 2.405E+000 8.473E-00 BI-212 288.20 0.34 2.025E+001 2.39E+000 1.673E+001 9.555E+00 328.03 0.13 6.417E+001 5.488E+001 3.034E+00 452.98 0.36 2.475E+001 -1.827E+001 1.153E+00 727.33 6.67 2.392E+000 4.370E-001 1.122E+00 785.37 1.10 1.322E+001 6.596E+000 6.128E+00 893.41 0.38 4.614E+001 -8.980E+000 2.149E+00 952.12 0.17 1.093E+002 -3.594E+000 5.097E+00 1078.62 0.56 3.424E+001 1.455E+001 1.587E+00 1512.70 0.29 5.869E+001 2.592E+001 2.611E+00 1620.50 1.47 1.009E+001 -4.850E+000 4.367E+00
+ Pb-212 74.82* 10.28 4.443E-001 9.65E-002 6.746E-001 2.108E-00 77.11* 17.10 2.212E-001 4.455E-001 1.039E-00 86.83 2.07 2.668E+000 2.733E+000 1.282E+00 87.35 3.97 1.342E+000 -3.876E-001 6.441E-00 89.78 1.46 3.369E+000 -7.860E+000 1.612E+00 115.18 0.60 6.389E+000 3.970E+000 3.022E+00 238.63* 43.60 9.650E-002 3.034E-001 4.460E-00 300.09 3.30 2.079E+000 -6.691E-001 9.790E-00 BI-214 76.86 0.55 1.373E+001 3.43E-001 0.000E+000 6.656E+00 79.29 0.91 6.354E+000 5.500E-001 3.053E+00 89.26 0.11 4.570E+001 2.489E+000 2.189E+00 89.81 0.21 2.342E+001 -5.464E+001 1.121E+00 273.80 0.13 4.911E+001 -5.514E+001 2.314E+00 348.92 0.10 8.709E+001 -1.325E+000 4.130E+00 386.78 0.29 2.917E+001 -4.424E+000 1.371E+00 388.89 0.40 2.065E+001 -8.404E+000 9.675E+00 405.72 0.17 4.973E+001 1.374E+001 2.325E+00 454.79 0.29 3.289E+001 1.085E+001 1.539E+00 469.77 0.13 7.953E+001 1.041E+001 3.735E+00 609.32 45.49 3.430E-001 2.918E-001 1.624E-00 665.45 1.53 8.977E+000 9.211E-001 4.193E+00 703.11 0.47 2.535E+001 1.356E+001 1.166E+00 719.87 0.39 3.675E+001 -2.485E+001 1.713E+00 752.85 0.13 1.148E+002 -3.486E+001 5.342E+00 768.36 4.89 3.036E+000 -1.293E+000 1.412E+00 786.35 0.32 4.518E+001 -7.872E-001 2.093E+00 806.18 1.26 1.119E+001 -1.790E+000 5.166E+00
Nuclide MDA Report 4/19/2017 10:41:26 AM Page 5 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram BI-214 821.18 0.16 9.183E+001 3.43E-001 2.533E+000 4.249E+00 826.45 0.12 1.358E+002 -6.761E+000 6.317E+00 934.06 3.11 5.098E+000 -5.998E-001 2.350E+00 964.08 0.37 5.614E+001 1.064E+001 2.632E+00 1051.96 0.31 6.188E+001 4.786E+001 2.874E+00 1069.96 0.27 6.683E+001 2.534E+001 3.085E+00 1120.29 14.92 1.392E+000 -5.838E-001 6.474E-00 1133.66 0.25 7.886E+001 -2.547E+001 3.651E+00 1155.21 1.63 1.095E+001 -4.170E+000 5.020E+00 1207.68 0.45 4.513E+001 -9.110E+000 2.085E+00 1238.11 5.83 4.249E+000 1.001E+000 1.989E+00 1280.98 1.43 1.267E+001 -2.934E+000 5.769E+00 1303.75 0.11 1.533E+002 -4.562E+001 6.894E+00 1377.67 3.99 4.722E+000 1.239E+000 2.144E+00 1385.31 0.79 1.948E+001 -7.115E+000 8.641E+00 1401.52 1.33 1.397E+001 4.231E+000 6.323E+00 1407.99 2.39 7.559E+000 3.842E+000 3.411E+00 1509.21 2.13 7.473E+000 -2.294E+000 3.296E+00 1538.53 0.40 3.873E+001 3.008E+001 1.697E+00 1543.34 0.30 4.968E+001 -7.380E+000 2.169E+00 1583.20 0.70 2.754E+001 1.981E+001 1.239E+00 1594.75 0.27 6.543E+001 -7.261E+000 2.903E+00 1599.37 0.32 4.663E+001 -1.750E+000 2.027E+00 1661.27 1.05 1.449E+001 7.528E+000 6.271E+00 1684.01 0.21 4.678E+001 -4.550E+001 1.856E+00 1729.59 2.88 5.470E+000 2.815E+000 2.367E+00 1764.49 15.30 1.401E+000 1.217E+000 6.300E-00 1838.36 0.35 4.614E+001 1.350E+001 1.986E+00 1847.43 2.03 8.012E+000 8.431E-001 3.450E+00 1873.16 0.21 8.852E+001 1.025E+001 3.893E+00 1896.05 0.15 9.094E+001 1.719E+000 3.771E+00
> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00
> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00
> 2293.38 0.31 0.000E+000 0.000E+000 0.000E+00
> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00
+ PB-214 74.82* 5.80 7.875E-001 1.52E-001 1.196E+000 3.736E-00 77.11* 9.70 3.899E-001 7.854E-001 1.832E-00 86.83 1.70 3.249E+000 3.328E+000 1.562E+00 87.35 2.24 2.378E+000 -6.870E-001 1.142E+00 89.78 0.82 5.999E+000 -1.399E+001 2.871E+00 241.99 7.25 1.260E+000 3.571E-001 6.076E-00 258.76 0.53 1.160E+001 4.661E+000 5.477E+00 274.80 0.35 1.777E+001 -5.842E+000 8.373E+00 295.22* 18.42 2.108E-001 2.785E-001 9.477E-00 351.93* 35.60 1.520E-001 1.529E-001 6.939E-00 462.02 0.21 4.453E+001 9.734E+000 2.079E+00 480.43 0.34 3.152E+001 1.007E+001 1.479E+00 487.14 0.43 2.210E+001 -1.576E+001 1.029E+00 533.66 0.18 5.235E+001 -2.869E+001 2.417E+00 580.14 0.37 3.662E+001 -1.580E+000 1.724E+00 785.96 1.06 1.375E+001 4.170E+000 6.375E+00
Nuclide MDA Report 4/19/2017 10:41:26 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram
+ PB-214 839.07 0.58 2.677E+001 1.52E-001 -1.630E+000 1.242E+00
+ Ra-226 81.07 0.20 2.145E+001 1.15E+000 -3.416E+000 1.016E+00 83.79 0.32 1.487E+001 -1.287E+000 7.100E+00 186.21* 3.64 1.150E+000 1.297E+000 5.396E-00 AC-228 89.96 1.90 1.293E+015 4.00E+014 -3.016E+015 6.186E+01 93.35 3.10 8.156E+014 4.908E+014 3.910E+01 99.51 1.26 1.470E+015 -1.658E+014 6.944E+01 104.82 0.39 5.423E+015 3.780E+015 2.580E+01 105.60 0.74 2.919E+015 2.102E+015 1.390E+01 108.58 0.28 7.270E+015 -2.249E+014 3.452E+01 129.07 2.42 7.911E+014 -2.008E+014 3.738E+01 145.85 0.16 1.424E+016 3.746E+015 6.773E+01 153.98 0.72 2.942E+015 1.076E+015 1.393E+01 191.35 0.12 2.119E+016 -2.714E+015 1.006E+01 199.41 0.31 8.912E+015 4.698E+015 4.241E+01 204.03 0.11 2.330E+016 -6.961E+015 1.103E+01 209.25 3.89 7.176E+014 3.322E+014 3.407E+01 214.85 0.76 3.697E+015 -2.108E+015 1.753E+01 270.24 3.46 9.328E+014 3.634E+013 4.405E+01 278.95 0.16 2.082E+016 1.084E+016 9.832E+01 321.65 0.23 1.594E+016 -1.801E+016 7.499E+01 327.44 0.12 3.349E+016 1.979E+016 1.584E+01 328.00 2.95 1.359E+015 1.162E+015 6.423E+01 332.37 0.40 9.968E+015 -1.431E+016 4.707E+01 338.32 11.27 4.045E+014 4.065E+014 1.922E+01 340.96 0.37 1.167E+016 1.707E+015 5.527E+01 409.46 1.92 2.309E+015 7.745E+014 1.083E+01 440.44 0.12 3.656E+016 -5.908E+015 1.705E+01 463.00 4.40 1.089E+015 -7.243E+013 5.090E+01 478.33 0.21 2.587E+016 1.037E+016 1.216E+01 503.82 0.18 2.914E+016 -2.526E+016 1.363E+01 508.96 0.45 1.525E+016 7.884E+015 7.240E+01 523.13 0.10 4.985E+016 1.245E+016 2.320E+01 546.47 0.20 2.829E+016 1.026E+015 1.322E+01 562.50 0.87 6.638E+015 3.580E+015 3.099E+01 570.91 0.18 2.938E+016 -1.875E+016 1.362E+01 572.14 0.15 3.603E+016 3.361E+015 1.672E+01 583.41 0.11 6.166E+016 2.845E+016 2.904E+01 674.75 2.10 3.291E+015 1.072E+015 1.537E+01 701.75 0.17 3.450E+016 -2.034E+015 1.587E+01 707.41 0.16 3.958E+016 -2.288E+015 1.824E+01 726.86 0.62 1.277E+016 4.108E+015 5.990E+01 755.32 1.00 7.420E+015 -6.736E+014 3.455E+01 772.29 1.49 5.084E+015 1.892E+015 2.367E+01 782.14 0.49 1.568E+016 8.407E+015 7.299E+01 794.95 4.25 1.746E+015 5.717E+014 8.101E+01 830.49 0.54 1.500E+016 1.416E+015 6.983E+01 835.71 1.61 5.208E+015 4.271E+015 2.430E+01 840.38 0.91 8.290E+015 -6.435E+015 3.836E+01 904.20 0.77 1.210E+016 -2.259E+016 5.657E+01 911.20 25.80 3.998E+014 3.116E+014 1.882E+01
Nuclide MDA Report 4/19/2017 10:41:26 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram AC-228 947.98 0.11 8.665E+016 4.00E+014 1.749E+016 4.037E+01 958.61 0.28 3.313E+016 3.813E+015 1.543E+01 964.77 4.99 2.090E+015 8.548E+014 9.813E+01 968.97 15.80 6.665E+014 5.943E+014 3.130E+01 1033.25 0.20 4.301E+016 2.299E+016 1.982E+01 1065.18 0.13 6.315E+016 -5.186E+016 2.894E+01 1095.68 0.13 6.238E+016 8.021E+015 2.843E+01 1110.61 0.28 3.196E+016 -3.177E+016 1.472E+01 1153.52 0.14 6.701E+016 6.051E+015 3.083E+01 1247.08 0.50 2.428E+016 1.277E+016 1.134E+01 1459.14 0.83 2.953E+016 8.173E+016 1.422E+01 1495.91 0.86 8.273E+015 3.016E+015 3.597E+01 1501.57 0.46 1.681E+016 -4.576E+014 7.390E+01 1557.11 0.18 4.259E+016 1.665E+016 1.859E+01 1580.53 0.60 1.443E+016 -1.201E+015 6.403E+01 1588.20 3.22 2.971E+015 2.479E+015 1.333E+01 1625.06 0.25 3.252E+016 2.608E+016 1.430E+01 1630.63 1.51 5.087E+015 2.713E+015 2.211E+01 1638.28 0.47 1.379E+016 -1.452E+015 5.825E+01 1666.52 0.18 3.699E+016 -8.918E+015 1.562E+01 TH-230 67.67 0.38 1.334E+001 1.33E+001 3.381E+000 6.329E+00 PA-234 742.81 0.11 1.361E+002 1.68E+001 -7.943E+001 6.334E+00 766.42 0.32 4.784E+001 -1.190E+001 2.229E+00 1001.03 0.84 1.677E+001 -8.268E+000 7.602E+00 TH-234 63.29 3.70 1.685E+000 1.69E+000 4.354E-001 8.049E-00 92.38 2.13 2.457E+000 2.632E+000 1.179E+00 92.80 2.10 2.482E+000 3.272E+000 1.191E+00 112.81 0.21 1.913E+001 1.317E+001 9.077E+00 U-234 53.20 0.12 5.473E+001 5.47E+001 1.249E+001 2.590E+00 120.90 0.04 1.024E+002 -1.066E+001 4.825E+00 U-235 72.70 0.12 5.033E+001 4.04E-001 -4.070E+000 2.417E+00 89.96 3.43 1.433E+000 -3.343E+000 6.858E-00 93.35 5.54 9.134E-001 5.496E-001 4.379E-00 104.82 0.69 6.179E+000 4.307E+000 2.940E+00 105.60 1.31 3.300E+000 2.376E+000 1.572E+00 108.58 0.50 8.148E+000 -2.520E-001 3.869E+00 109.19 1.66 2.376E+000 -1.663E+000 1.126E+00 140.76 0.20 2.088E+001 -1.653E+001 9.894E+00 143.76 10.96 4.036E-001 -7.681E-002 1.918E-00 163.36 5.08 8.429E-001 5.350E-002 3.983E-00 182.62 0.39 1.511E+001 -3.608E+000 7.231E+00 194.94 0.63 8.726E+000 -6.456E-001 4.151E+00 202.12 1.08 5.025E+000 -5.875E-002 2.386E+00 205.32 5.02 1.055E+000 2.561E-002 4.999E-00 221.39 0.12 4.749E+001 -2.430E+001 2.248E+00
+ = Nuclide identified during the nuclide identification
- = Energy line found in the spectrum
> = MDA value not calculated
@ = Half-life too short to be able to perform the decay correction
4/19/2017 10:41:26 LACE Lace v3.2.1 Page 1
- L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================
Analysis using Key Line Activities
===================================================
Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2120\\W6H-IMC-212 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:
'^' Denotes Key Line energy
- All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]
K-40 1460.8 ^ 1.17E+001 16.258 Pb-210 46.5 ^ 2.40E+000 43.811 Pb-212 74.8 6.75E-001 36.723 2.224[45.435] 2.79 -0.511 77.1 4.46E-001 33.097 1.469[42.559] [ 0.428]
238.6 ^ 3.03E-001 26.755 1.000[37.837]
PB-214 74.8 1.20E+000 37.797 7.822[63.284] 6.51 -1.076 77.1 7.85E-001 34.300 5.137[61.260] [ 0.457]
295.2 2.78E-001 44.420 1.822[67.449]
351.9 ^ 1.53E-001 50.757 1.000[71.781]
Ra-226 186.2 ^ 1.30E+000 42.432