Text

BUILDING 6H CENTER 118 117 31 22 30 18 25 24 17 23 27 19 26 28 21 29 20 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 p

0 20 40 Scale (feet)

PROJECT No. 10-1007.00 10/2017 FIGURE 8-6 FORMER UNC FACILITY NEW HAVEN, CONNECTICUT ALPHA-BETA FLOOR SCAN SURVEY RESULTS Legend Area of Elevated Gamma Activity Floor Scan Results (Alpha + Beta dpm/100 cm2)

< 99.9 100 - 2,499.9 2,500 - 4,999.9

> 5,000 Building 3H Building 6H

")

Building Columns Note: Survey performed with Ludlum 2360/ 43-37. All measurements are 1-min integrated scans. Survey results represent the centroid of the area scanned during the 1-min interval.