          • G A M M A S P E C T R U M A N A L Y S I S *****

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2079\\W6H-IMC-207 Report Generated On : 5/1/2017 10:01:09 AM Sample Title : W6H-IMC-2079-S-P-8 Sample Description :

Sample Identification : 2079-S-P-8 Sample Type :

Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 2.861E+002 grams Sample Taken On : 3/17/2017 12:00:00 AM Acquisition Started : 3/31/2017 2:02:31 PM Live Time : 1800.0 seconds Real Time : 1800.3 seconds Dead Time : 0.02 %

Energy Calibration Used Done On : 3/24/2017 Efficiency Calibration Used Done On : 5/1/2017 Efficiency ID : H-IMC-2079-S-P-8

Peak Analysis Report 5/1/2017 10:01:09 AM Page 1

          • P E A K A N A L Y S I S R E P O R T *****

Detector Name: 8566 Sample

Title:

W6H-IMC-2079-S-P-8 Peak Analysis Performed on: 5/1/2017 10:01:05 AM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts F 1 179-190 186.09 46.72 0.77 6.04E+001 18.74 4.00E+001 M 2 295-316 299.87 75.18 0.63 5.88E+001 20.46 6.86E+001 m 3 295-316 308.91 77.44 0.64 4.83E+001 17.52 4.57E+001 F 4 365-377 370.23 92.78 1.04 5.00E+001 18.11 4.12E+001 F 5 949-958 953.02 238.57 0.85 5.81E+001 19.48 4.50E+001 F 6 1400- 1410 1405.09 351.65 1.05 2.91E+001 14.44 2.42E+001 F 7 5824-5851 5836.72 1460.21 3.13 1.51E+002 22.40 9.33E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma

Interference Corrected Activity Report 5/1/2017 10:01:09 AM Page 2

          • N U C L I D E I D E N T I F I C A T I O N R E P O R T *****

Sample

Title:

W6H-IMC-2079-S-P-8 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL

.................... IDENTIFIED NUCLIDES....................

Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.941 1460.82* 10.66 9.36266E+000 1.60009E+000 Pb-210 0.995 46.54* 4.25 2.45316E+000 1.03067E+000 Pb-212 0.993 74.82* 10.28 4.88728E-001 1.96612E-001 77.11* 17.10 2.36197E-001 9.79303E-002 86.83 2.07 87.35 3.97 89.78 1.46 115.18 0.60 238.63* 43.60 1.53882E-001 5.70962E-002 300.09 3.30 PB-214 0.658 74.82* 5.80 8.66228E-001 3.56993E-001 77.11* 9.70 4.16388E-001 1.76663E-001 86.83 1.70 87.35 2.24 89.78 0.82 241.99 7.25 258.76 0.53 274.80 0.35 295.22 18.42 351.93* 35.60 1.39411E-001 7.21945E-002 462.02 0.21 480.43 0.34 487.14 0.43 533.66 0.18 580.14 0.37 785.96 1.06 839.07 0.58 TH-234 0.330 63.29 3.70 92.38 2.13 92.80* 2.10 1.81588E+000 8.21148E-001 112.81 0.21 U-235 0.507 72.70 0.12 89.96 3.43 93.35* 5.54 6.88328E-001 2.85551E-001 104.82 0.69 105.60 1.31 108.58 0.50 109.19 1.66 140.76 0.20 143.76 10.96 163.36 5.08 182.62 0.39

Interference Corrected Activity Report 5/1/2017 10:01:09 AM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty U-235 0.507 194.94 0.63 202.12 1.08 205.32 5.02 221.39 0.12

  • = Energy line found in the spectrum.

@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma

Interference Corrected Activity Report 5/1/2017 10:01:09 AM Page 4

          • I N T E R F E R E N C E C O R R E C T E D R E P O R T *****

Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.941 9.362665E+000 1.600090E+000 Pb-210 0.995 2.453160E+000 1.030670E+000 Pb-212 0.993 1.678092E-001 4.903705E-002 PB-214 0.658 1.519902E-001 6.719017E-002

? TH-234 0.330 1.815875E+000 8.211482E-001

? U-235 0.507 6.883281E-001 2.855511E-001

? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis

@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma

                    • U N I D E N T I F I E D P E A K S **********

Peak Locate Performed on: 5/1/2017 10:01:05 AM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.

No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.

Nuclide MDA Report 5/1/2017 10:01:09 AM Page 5

          • N U C L I D E M D A R E P O R T *****

Detector Name: 8566 Sample Geometry: cylinder Sample

Title:

W6H-IMC-2079-S-P-8 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ K-40 1460.82* 10.66 1.163E+000 1.16E+000 9.363E+000 4.977E-00 CO-60 1173.23 99.85 1.688E-001 1.65E-001 -5.374E-002 7.694E-00 1332.49 99.98 1.650E-001 -5.591E-002 7.418E-00 CS-137 661.66 85.10 1.291E-001 1.29E-001 1.373E-003 5.934E-00

+ Pb-210 46.54* 4.25 1.574E+000 1.57E+000 2.453E+000 7.319E-00 BI-212 288.20 0.34 1.806E+001 2.11E+000 2.226E+000 8.471E+00 328.03 0.13 5.251E+001 -4.126E+001 2.454E+00 452.98 0.36 2.504E+001 -2.179E+001 1.169E+00 727.33 6.67 2.111E+000 1.341E-001 9.829E-00 785.37 1.10 1.207E+001 -2.667E+000 5.564E+00 893.41 0.38 3.318E+001 -5.324E+001 1.505E+00 952.12 0.17 9.576E+001 -2.269E+001 4.424E+00 1078.62 0.56 3.217E+001 1.620E+001 1.486E+00 1512.70 0.29 5.522E+001 1.200E+001 2.443E+00 1620.50 1.47 1.158E+001 7.907E+000 5.123E+00

+ Pb-212 74.82* 10.28 3.430E-001 9.49E-002 4.887E-001 1.602E-00 77.11* 17.10 1.669E-001 2.362E-001 7.684E-00 86.83 2.07 2.211E+000 6.798E-001 1.054E+00 87.35 3.97 1.115E+000 -7.856E-001 5.309E-00 89.78 1.46 2.708E+000 9.243E-001 1.283E+00 115.18 0.60 5.728E+000 1.047E+000 2.694E+00 238.63* 43.60 9.492E-002 1.539E-001 4.387E-00 300.09 3.30 2.098E+000 -9.432E-001 9.894E-00 BI-214 76.86 0.55 1.118E+001 2.70E-001 1.467E+001 5.380E+00 79.29 0.91 5.200E+000 9.065E-002 2.477E+00 89.26 0.11 3.619E+001 2.482E+001 1.714E+00 89.81 0.21 1.883E+001 6.425E+000 8.918E+00 273.80 0.13 4.830E+001 2.248E+001 2.276E+00 348.92 0.10 7.784E+001 6.186E+001 3.672E+00 386.78 0.29 2.663E+001 -2.559E+000 1.245E+00 388.89 0.40 1.926E+001 -1.558E+000 8.990E+00 405.72 0.17 4.823E+001 -7.163E+000 2.253E+00 454.79 0.29 3.233E+001 -7.663E+000 1.513E+00 469.77 0.13 5.886E+001 -6.663E+001 2.706E+00 609.32 45.49 2.705E-001 1.707E-001 1.263E-00 665.45 1.53 8.058E+000 1.212E+000 3.738E+00 703.11 0.47 2.686E+001 -7.920E+000 1.244E+00 719.87 0.39 3.530E+001 -1.130E+001 1.643E+00 752.85 0.13 1.093E+002 1.733E+001 5.073E+00 768.36 4.89 3.051E+000 2.046E+000 1.422E+00 786.35 0.32 3.995E+001 -4.468E+001 1.835E+00 806.18 1.26 1.179E+001 7.344E-001 5.472E+00

Nuclide MDA Report 5/1/2017 10:01:09 AM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram BI-214 821.18 0.16 8.524E+001 2.70E-001 5.686E+000 3.925E+00 826.45 0.12 1.106E+002 -7.551E+001 5.066E+00 934.06 3.11 5.384E+000 -1.705E+000 2.496E+00 964.08 0.37 5.479E+001 2.224E+001 2.568E+00 1051.96 0.31 5.235E+001 1.583E+001 2.402E+00 1069.96 0.27 6.864E+001 2.093E+001 3.180E+00 1120.29 14.92 1.335E+000 9.349E-001 6.196E-00 1133.66 0.25 6.879E+001 -1.005E+001 3.153E+00 1155.21 1.63 1.013E+001 -7.031E-001 4.619E+00 1207.68 0.45 4.089E+001 -9.410E+000 1.876E+00 1238.11 5.83 3.498E+000 1.818E+000 1.616E+00 1280.98 1.43 1.211E+001 2.058E+000 5.499E+00 1303.75 0.11 1.799E+002 6.718E+001 8.237E+00 1377.67 3.99 4.015E+000 9.361E-001 1.795E+00 1385.31 0.79 2.029E+001 1.326E+000 9.069E+00 1401.52 1.33 1.430E+001 5.591E+000 6.500E+00 1407.99 2.39 7.758E+000 3.579E+000 3.517E+00 1509.21 2.13 7.827E+000 1.081E+000 3.482E+00 1538.53 0.40 3.702E+001 -1.216E+001 1.616E+00 1543.34 0.30 4.602E+001 -2.059E+001 1.991E+00 1583.20 0.70 2.144E+001 4.526E+000 9.358E+00 1594.75 0.27 5.539E+001 -1.262E+001 2.408E+00 1599.37 0.32 4.442E+001 4.784E+000 1.922E+00 1661.27 1.05 1.232E+001 -5.480E+000 5.202E+00 1684.01 0.21 6.824E+001 3.310E+001 2.938E+00 1729.59 2.88 5.024E+000 2.229E+000 2.151E+00 1764.49 15.30 1.060E+000 5.805E-001 4.608E-00 1838.36 0.35 4.049E+001 6.275E+000 1.710E+00 1847.43 2.03 7.598E+000 4.238E-001 3.253E+00 1873.16 0.21 7.541E+001 2.051E+001 3.247E+00 1896.05 0.15 1.096E+002 -3.516E+001 4.718E+00

> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00

> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00

> 2293.38 0.31 0.000E+000 0.000E+000 0.000E+00

> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00

+ PB-214 74.82* 5.80 6.079E-001 1.25E-001 8.662E-001 2.840E-00 77.11* 9.70 2.942E-001 4.164E-001 1.355E-00 86.83 1.70 2.692E+000 8.278E-001 1.284E+00 87.35 2.24 1.976E+000 -1.392E+000 9.409E-00 89.78 0.82 4.822E+000 1.646E+000 2.284E+00 241.99 7.25 1.043E+000 -1.756E-001 4.999E-00 258.76 0.53 1.135E+001 -2.351E-002 5.359E+00 274.80 0.35 1.673E+001 2.836E+000 7.860E+00 295.22 18.42 3.696E-001 1.237E-002 1.743E-00 351.93* 35.60 1.254E-001 1.394E-001 5.623E-00 462.02 0.21 4.497E+001 3.219E+001 2.103E+00 480.43 0.34 2.807E+001 -5.448E+000 1.308E+00 487.14 0.43 2.254E+001 -1.270E+001 1.052E+00 533.66 0.18 5.518E+001 2.334E+001 2.562E+00 580.14 0.37 3.317E+001 1.087E+001 1.554E+00 785.96 1.06 1.206E+001 -1.348E+001 5.537E+00

Nuclide MDA Report 5/1/2017 10:01:09 AM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ PB-214 839.07 0.58 2.715E+001 1.25E-001 1.907E+001 1.263E+00 Ra-226 81.07 0.20 1.855E+001 1.50E+000 -5.652E+000 8.713E+00 83.79 0.32 1.373E+001 1.174E+001 6.533E+00 186.21 3.64 1.496E+000 1.602E+000 7.134E-00 AC-228 89.96 1.90 2.911E+017 9.23E+016 9.934E+016 1.379E+01 93.35 3.10 1.800E+017 1.031E+017 8.537E+01 99.51 1.26 3.738E+017 2.682E+017 1.756E+01 104.82 0.39 1.180E+018 -1.429E+017 5.539E+01 105.60 0.74 6.471E+017 3.481E+017 3.045E+01 108.58 0.28 1.633E+018 -5.219E+017 7.660E+01 129.07 2.42 2.132E+017 -2.163E+017 1.006E+01 145.85 0.16 3.286E+018 4.099E+017 1.547E+01 153.98 0.72 7.435E+017 5.092E+017 3.500E+01 191.35 0.12 5.358E+018 1.809E+018 2.532E+01 199.41 0.31 2.046E+018 8.836E+017 9.636E+01 204.03 0.11 5.801E+018 4.561E+017 2.730E+01 209.25 3.89 1.611E+017 -6.382E+016 7.553E+01 214.85 0.76 8.735E+017 5.545E+017 4.105E+01 270.24 3.46 2.558E+017 7.009E+016 1.207E+01 278.95 0.16 5.058E+018 2.823E+017 2.370E+01 321.65 0.23 4.192E+018 1.348E+018 1.966E+01 327.44 0.12 7.945E+018 -1.016E+018 3.723E+01 328.00 2.95 3.114E+017 -2.447E+017 1.455E+01 332.37 0.40 2.164E+018 -1.802E+018 1.006E+01 338.32 11.27 9.232E+016 8.550E+016 4.340E+01 340.96 0.37 2.762E+018 1.222E+018 1.296E+01 409.46 1.92 6.242E+017 4.543E+017 2.923E+01 440.44 0.12 1.021E+019 -3.567E+018 4.766E+01 463.00 4.40 2.958E+017 8.944E+016 1.381E+01 478.33 0.21 6.167E+018 3.159E+018 2.870E+01 503.82 0.18 8.383E+018 -5.343E+018 3.932E+01 508.96 0.45 4.231E+018 5.534E+018 2.010E+01 523.13 0.10 1.286E+019 6.151E+017 5.953E+01 546.47 0.20 7.008E+018 4.708E+017 3.249E+01 562.50 0.87 1.681E+018 4.928E+017 7.799E+01 570.91 0.18 8.157E+018 -5.434E+016 3.784E+01 572.14 0.15 1.016E+019 7.269E+017 4.723E+01 583.41 0.11 1.496E+019 4.280E+018 6.987E+01 674.75 2.10 8.194E+017 -1.428E+017 3.796E+01 701.75 0.17 1.033E+019 -1.799E+018 4.785E+01 707.41 0.16 1.210E+019 -1.574E+017 5.625E+01 726.86 0.62 3.224E+018 1.494E+018 1.503E+01 755.32 1.00 1.865E+018 0.000E+000 8.623E+01 772.29 1.49 1.334E+018 -7.290E+017 6.191E+01 782.14 0.49 4.008E+018 2.527E+018 1.854E+01 794.95 4.25 4.684E+017 7.225E+016 2.169E+01 830.49 0.54 3.665E+018 -1.079E+018 1.691E+01 835.71 1.61 1.317E+018 2.704E+017 6.104E+01 840.38 0.91 2.380E+018 1.483E+017 1.105E+01 904.20 0.77 3.435E+018 7.316E+017 1.610E+01 911.20 25.80 1.070E+017 -1.994E+016 5.026E+01

Nuclide MDA Report 5/1/2017 10:01:09 AM Page 8 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram AC-228 947.98 0.11 2.141E+019 9.23E+016 -9.397E+017 9.893E+01 958.61 0.28 8.628E+018 -2.141E+018 4.003E+01 964.77 4.99 5.682E+017 4.768E+017 2.666E+01 968.97 15.80 1.746E+017 1.306E+017 8.175E+01 1033.25 0.20 1.060E+019 4.124E+018 4.838E+01 1065.18 0.13 1.813E+019 3.107E+018 8.341E+01 1095.68 0.13 2.171E+019 1.166E+019 1.010E+01 1110.61 0.28 9.467E+018 -8.179E+017 4.386E+01 1153.52 0.14 1.643E+019 -5.842E+018 7.479E+01 1247.08 0.50 5.587E+018 -1.312E+018 2.575E+01 1459.14 0.83 7.248E+018 1.838E+019 3.474E+01 1495.91 0.86 2.523E+018 1.268E+018 1.113E+01 1501.57 0.46 5.442E+018 1.521E+018 2.442E+01 1557.11 0.18 1.139E+019 6.134E+018 4.950E+01 1580.53 0.60 3.217E+018 2.477E+017 1.385E+01 1588.20 3.22 6.937E+017 6.868E+016 3.050E+01 1625.06 0.25 9.571E+018 6.794E+018 4.247E+01 1630.63 1.51 1.399E+018 4.798E+017 6.080E+01 1638.28 0.47 3.792E+018 -2.117E+018 1.602E+01 1666.52 0.18 1.137E+019 -2.773E+018 4.897E+01 TH-230 67.67 0.38 1.300E+001 1.30E+001 7.072E+000 6.163E+00 PA-234 742.81 0.11 1.347E+002 1.90E+001 1.000E+002 6.273E+00 766.42 0.32 4.558E+001 9.486E+000 2.119E+00 1001.03 0.84 1.904E+001 -7.375E+000 8.754E+00

+ TH-234 63.29 3.70 1.570E+000 1.46E+000 6.062E-001 7.476E-00 92.38 2.13 2.013E+000 1.846E+000 9.582E-00 92.80* 2.10 1.462E+000 1.816E+000 6.820E-00 112.81 0.21 1.530E+001 -1.014E+001 7.168E+00 U-234 53.20 0.12 4.496E+001 4.50E+001 -3.960E+000 2.102E+00 120.90 0.04 9.384E+001 -2.614E+001 4.400E+00

+ U-235 72.70 0.12 4.345E+001 3.50E-001 2.564E+000 2.073E+00 89.96 3.43 1.152E+000 3.931E-001 5.456E-00 93.35* 5.54 5.543E-001 6.883E-001 2.585E-00 104.82 0.69 4.801E+000 -5.811E-001 2.253E+00 105.60 1.31 2.612E+000 1.405E+000 1.229E+00 108.58 0.50 6.533E+000 -2.088E+000 3.065E+00 109.19 1.66 1.932E+000 -9.361E-001 9.052E-00 140.76 0.20 1.912E+001 -7.770E+000 9.024E+00 143.76 10.96 3.504E-001 2.142E-001 1.654E-00 163.36 5.08 8.416E-001 4.720E-001 3.980E-00 182.62 0.39 1.310E+001 -5.741E+000 6.231E+00 194.94 0.63 7.511E+000 5.776E-001 3.547E+00 202.12 1.08 4.148E+000 -2.810E+000 1.949E+00 205.32 5.02 9.736E-001 7.661E-001 4.595E-00 221.39 0.12 4.008E+001 -1.601E+000 1.880E+00

+ = Nuclide identified during the nuclide identification

  • = Energy line found in the spectrum

> = MDA value not calculated

@ = Half-life too short to be able to perform the decay correction

5/1/2017 10:01:09 LACE Lace v3.2.1 Page 1

        • L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================

Analysis using Key Line Activities

===================================================

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2079\\W6H-IMC-207 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:

'^' Denotes Key Line energy

  • All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]

K-40 1460.8 ^ 9.36E+000 17.090 Pb-210 46.5 ^ 2.45E+000 42.014 Pb-212 74.8 4.89E-001 40.229 3.176[54.728] 3.87 -0.708 77.1 2.36E-001 41.461 1.535[55.639] [ 0.571]

238.6 ^ 1.54E-001 37.104 1.000[52.473]

PB-214 74.8 8.66E-001 41.212 6.213[66.183] 5.64 -0.963 77.1 4.16E-001 42.428 2.987[66.946] [ 0.568]

351.9 ^ 1.39E-001 51.785 1.000[73.235]

TH-234 92.8 1.82E+000 ******

U-235 93.3 6.88E-001 ******