ML19095B312

From kanterella
Jump to navigation Jump to search
Appendix E, On-Site Lab Waste Sample Data, Gamma Spec Reports - W6H-IMC-2008-S-P-5
ML19095B312
Person / Time
Site: 07000371
Issue date: 03/01/2018
From:
Cabrera Services
To:
NRC Region 1
Shared Package
ml051740240 List: ... further results
References
Download: ML19095B312 (11)


Text

          • G A M M A S P E C T R U M A N A L Y S I S *****

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2008\\W6H-IMC-200 Report Generated On : 3/27/2017 12:14:11 PM Sample Title : W6H-IMC-2008-S-P-5 Sample Description :

Sample Identification : 2008-S-P-5 Sample Type :

Sample Geometry : cylinder Peak Locate Threshold : 3.00 Peak Locate Range (in channels) : 40 - 8192 Peak Area Range (in channels) : 40 - 8192 Identification Energy Tolerance : 1.000 keV Sample Size : 3.296E+002 grams Sample Taken On : 3/17/2017 12:00:00 AM Acquisition Started : 3/27/2017 11:37:12 AM Live Time : 1800.0 seconds Real Time : 1800.3 seconds Dead Time : 0.02 %

Energy Calibration Used Done On : 3/24/2017 Efficiency Calibration Used Done On : 3/27/2017 Efficiency ID : H-IMC-2008-S-P-5

Peak Analysis Report 3/27/2017 12:14:11 PM Page 1

          • P E A K A N A L Y S I S R E P O R T *****

Detector Name: 8566 Sample

Title:

W6H-IMC-2008-S-P-5 Peak Analysis Performed on: 3/27/2017 12:14:06 PM Peak Analysis From Channel: 40 Peak Analysis To Channel: 8192 Peak ROI ROI Peak Energy FWHM Net Peak Net Area Continuum No. start end centroid (keV) (keV) Area Uncert. Counts F 1 178-190 186.64 46.86 0.62 6.51E+001 19.41 5.42E+001 M 2 296-314 299.69 75.14 0.80 1.03E+002 25.76 8.40E+001 m 3 296-314 308.55 77.35 0.81 1.06E+002 25.17 8.51E+001 F 4 346-353 348.65 87.38 0.67 4.79E+001 17.87 4.27E+001 F 5 739-748 742.42 185.88 0.93 4.18E+001 18.20 5.00E+001 F 6 946-959 953.16 238.60 0.94 1.17E+002 25.25 6.48E+001 F 7 1174-1182 1178.90 295.07 0.96 3.56E+001 16.15 3.06E+001 F 8 1396-1413 1405.34 351.71 1.15 7.97E+001 20.18 3.60E+001 F 9 2426-2443 2434.19 609.07 1.54 4.66E+001 17.03 3.00E+001 F 10 5824-5849 5836.06 1460.04 2.43 1.86E+002 25.78 5.78E+000 M = First peak in a multiplet region m = Other peak in a multiplet region F = Fitted singlet Errors quoted at 1.960 sigma

Interference Corrected Activity Report 3/27/2017 12:14:11 PM Page 2

          • N U C L I D E I D E N T I F I C A T I O N R E P O R T *****

Sample

Title:

W6H-IMC-2008-S-P-5 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL

.................... IDENTIFIED NUCLIDES....................

Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty K-40 0.907 1460.82* 10.66 9.55762E+000 1.55213E+000 Pb-210 0.984 46.54* 4.25 2.52776E+000 1.03844E+000 Pb-212 0.996 74.82* 10.28 7.70380E-001 2.47597E-001 77.11* 17.10 4.66744E-001 1.44992E-001 86.83 2.07 87.35* 3.97 8.33515E-001 3.53439E-001 89.78 1.46 115.18 0.60 238.63* 43.60 2.63570E-001 7.04671E-002 300.09 3.30 BI-214 0.267 76.86* 0.55 1.46446E+001 4.56829E+000 79.29 0.91 89.26 0.11 89.81 0.21 273.80 0.13 348.92 0.10 386.78 0.29 388.89 0.40 405.72 0.17 454.79 0.29 469.77 0.13 609.32* 45.49 2.58829E-001 9.93150E-002 665.45 1.53 703.11 0.47 719.87 0.39 752.85 0.13 768.36 4.89 786.35 0.32 806.18 1.26 821.18 0.16 826.45 0.12 934.06 3.11 964.08 0.37 1051.96 0.31 1069.96 0.27 1120.29 14.92 1133.66 0.25 1155.21 1.63 1207.68 0.45 1238.11 5.83 1280.98 1.43 1303.75 0.11

Interference Corrected Activity Report 3/27/2017 12:14:11 PM Page 3 Nuclide Id Energy Yield Activity Activity Name Confidence (keV) (%) (pCi/gram) Uncertainty BI-214 0.267 1377.67 3.99 1385.31 0.79 1401.52 1.33 1407.99 2.39 1509.21 2.13 1538.53 0.40 1543.34 0.30 1583.20 0.70 1594.75 0.27 1599.37 0.32 1661.27 1.05 1684.01 0.21 1729.59 2.88 1764.49 15.30 1838.36 0.35 1847.43 2.03 1873.16 0.21 1896.05 0.15 2118.51 1.16 2204.06 4.92 2293.38 0.31 2447.70 1.55 PB-214 0.848 74.82* 5.80 1.36543E+000 4.55533E-001 77.11* 9.70 8.22817E-001 2.66122E-001 86.83 1.70 87.35* 2.24 1.47726E+000 6.38980E-001 89.78 0.82 241.99 7.25 258.76 0.53 274.80 0.35 295.22* 18.42 2.32734E-001 1.11602E-001 351.93* 35.60 3.22303E-001 9.42935E-002 462.02 0.21 480.43 0.34 487.14 0.43 533.66 0.18 580.14 0.37 785.96 1.06 839.07 0.58 Ra-226 0.985 81.07 0.20 83.79 0.32 186.21* 3.64 9.15749E-001 4.27961E-001

  • = Energy line found in the spectrum.

@ = Energy line not used for Weighted Mean Activity Energy Tolerance : 1.000 keV Nuclide confidence index threshold = 0.10 Errors quoted at 1.960 sigma

Interference Corrected Activity Report 3/27/2017 12:14:11 PM Page 4

          • I N T E R F E R E N C E C O R R E C T E D R E P O R T *****

Nuclide Wt mean Wt mean Nuclide Id Activity Activity Name Confidence (pCi/gram) Uncertainty K-40 0.907 9.557622E+000 1.552134E+000 Pb-210 0.984 2.527764E+000 1.038441E+000 Pb-212 0.996 2.991340E-001 6.106024E-002 BI-214 0.267 2.586106E-001 9.928006E-002 PB-214 0.848 3.060966E-001 6.899667E-002 Ra-226 0.985 9.157487E-001 4.279607E-001

? = nuclide is part of an undetermined solution X = nuclide rejected by the interference analysis

@ = nuclide contains energy lines not used in Weighted Mean Activity Errors quoted at 1.960 sigma

                    • U N I D E N T I F I E D P E A K S **********

Peak Locate Performed on: 3/27/2017 12:14:06 PM Peak Locate From Channel: 40 Peak Locate To Channel: 8192 Peak Energy Peak Size in Peak CPS Peak Tol.

No. (keV) Counts per Second % Uncertainty Type Nuclide All peaks were identified.

Nuclide MDA Report 3/27/2017 12:14:11 PM Page 5

          • N U C L I D E M D A R E P O R T *****

Detector Name: 8566 Sample Geometry: cylinder Sample

Title:

W6H-IMC-2008-S-P-5 Nuclide Library Used: C:\\GENIE2K\\CAMFILES\\UNC 2017 Full NLB.NL Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ K-40 1460.82* 10.66 7.728E-001 7.73E-001 9.558E+000 3.170E-00 CO-60 1173.23 99.85 1.742E-001 1.47E-001 -1.371E-002 8.094E-00 1332.49 99.98 1.474E-001 -2.539E-003 6.682E-00 CS-137 661.66 85.10 1.265E-001 1.26E-001 -3.812E-002 5.890E-00

+ Pb-210 46.54* 4.25 1.779E+000 1.78E+000 2.528E+000 8.368E-00 BI-212 288.20 0.34 1.795E+001 2.01E+000 9.585E+000 8.505E+00 328.03 0.13 4.749E+001 -1.179E+001 2.229E+00 452.98 0.36 2.204E+001 1.702E+001 1.032E+00 727.33 6.67 2.010E+000 1.950E+000 9.442E-00 785.37 1.10 1.110E+001 -1.144E+000 5.158E+00 893.41 0.38 3.573E+001 4.694E+000 1.658E+00 952.12 0.17 9.002E+001 6.995E+000 4.198E+00 1078.62 0.56 2.746E+001 2.641E+001 1.271E+00 1512.70 0.29 3.658E+001 -1.285E+001 1.566E+00 1620.50 1.47 7.095E+000 -3.960E+000 2.996E+00

+ Pb-212 74.82* 10.28 3.394E-001 1.05E-001 7.704E-001 1.596E-00 77.11* 17.10 2.002E-001 4.667E-001 9.414E-00 86.83 2.07 2.345E+000 1.374E+000 1.127E+00 87.35* 3.97 6.188E-001 8.335E-001 2.859E-00 89.78 1.46 3.092E+000 -1.496E+000 1.483E+00 115.18 0.60 5.430E+000 6.738E-001 2.567E+00 238.63* 43.60 1.048E-001 2.636E-001 4.936E-00 300.09 3.30 1.893E+000 -3.940E+000 8.961E-00

+ BI-214 76.86* 0.55 6.280E+000 1.73E-001 1.464E+001 2.954E+00 79.29 0.91 5.843E+000 -1.338E+000 2.812E+00 89.26 0.11 4.158E+001 -6.946E+000 1.995E+00 89.81 0.21 2.150E+001 -1.040E+001 1.031E+00 273.80 0.13 4.415E+001 1.945E+001 2.090E+00 348.92 0.10 8.219E+001 -2.100E+001 3.924E+00 386.78 0.29 2.345E+001 -3.770E-001 1.099E+00 388.89 0.40 1.803E+001 3.975E+000 8.475E+00 405.72 0.17 4.481E+001 1.749E+001 2.107E+00 454.79 0.29 2.571E+001 -4.990E+000 1.198E+00 469.77 0.13 6.642E+001 1.473E+000 3.122E+00 609.32* 45.49 1.731E-001 2.588E-001 7.905E-00 665.45 1.53 7.274E+000 2.809E+000 3.394E+00 703.11 0.47 2.396E+001 1.271E+001 1.115E+00 719.87 0.39 3.166E+001 -1.775E+001 1.481E+00 752.85 0.13 9.343E+001 2.170E+001 4.345E+00 768.36 4.89 2.528E+000 1.409E+000 1.177E+00 786.35 0.32 3.828E+001 -2.588E+001 1.778E+00 806.18 1.26 1.007E+001 2.339E+000 4.683E+00

Nuclide MDA Report 3/27/2017 12:14:11 PM Page 6 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ BI-214 821.18 0.16 7.785E+001 1.73E-001 2.816E+000 3.612E+00 826.45 0.12 1.179E+002 -2.441E+001 5.508E+00 934.06 3.11 4.289E+000 -2.495E+000 1.981E+00 964.08 0.37 4.859E+001 2.285E+001 2.287E+00 1051.96 0.31 4.537E+001 -1.457E+001 2.089E+00 1069.96 0.27 5.401E+001 -2.898E+000 2.492E+00 1120.29 14.92 1.135E+000 4.175E-001 5.279E-00 1133.66 0.25 6.429E+001 1.944E+001 2.977E+00 1155.21 1.63 9.598E+000 -9.854E+000 4.427E+00 1207.68 0.45 3.906E+001 1.555E+001 1.813E+00 1238.11 5.83 3.438E+000 2.338E+000 1.609E+00 1280.98 1.43 1.169E+001 4.947E+000 5.383E+00 1303.75 0.11 1.067E+002 -1.230E+002 4.706E+00 1377.67 3.99 3.787E+000 -6.523E-002 1.717E+00 1385.31 0.79 1.772E+001 -6.738E+000 7.968E+00 1401.52 1.33 1.119E+001 -4.344E+000 5.057E+00 1407.99 2.39 7.194E+000 4.132E+000 3.298E+00 1509.21 2.13 5.630E+000 -6.896E-001 2.457E+00 1538.53 0.40 3.064E+001 1.198E+001 1.337E+00 1543.34 0.30 3.923E+001 1.388E+001 1.706E+00 1583.20 0.70 2.345E+001 1.220E+001 1.060E+00 1594.75 0.27 5.943E+001 7.370E+000 2.673E+00 1599.37 0.32 4.199E+001 -1.319E+000 1.852E+00 1661.27 1.05 1.280E+001 5.789E+000 5.609E+00 1684.01 0.21 6.002E+001 1.260E+001 2.609E+00 1729.59 2.88 4.299E+000 2.868E+000 1.851E+00 1764.49 15.30 1.155E+000 7.208E-001 5.204E-00 1838.36 0.35 4.711E+001 1.421E+001 2.096E+00 1847.43 2.03 7.667E+000 1.468E+000 3.382E+00 1873.16 0.21 5.571E+001 -5.421E+001 2.353E+00 1896.05 0.15 8.430E+001 3.323E+001 3.586E+00

> 2118.51 1.16 0.000E+000 0.000E+000 0.000E+00

> 2204.06 4.92 0.000E+000 0.000E+000 0.000E+00

> 2293.38 0.31 0.000E+000 0.000E+000 0.000E+00

> 2447.70 1.55 0.000E+000 0.000E+000 0.000E+00

+ PB-214 74.82* 5.80 6.015E-001 1.44E-001 1.365E+000 2.828E-00 77.11* 9.70 3.528E-001 8.228E-001 1.660E-00 86.83 1.70 2.855E+000 1.673E+000 1.372E+00 87.35* 2.24 1.097E+000 1.477E+000 5.066E-00 89.78 0.82 5.505E+000 -2.663E+000 2.640E+00 241.99 7.25 1.037E+000 -3.219E-001 4.997E-00 258.76 0.53 9.664E+000 3.266E+000 4.563E+00 274.80 0.35 1.612E+001 -1.578E-001 7.632E+00 295.22* 18.42 1.814E-001 2.327E-001 8.189E-00 351.93* 35.60 1.445E-001 3.223E-001 6.677E-00 462.02 0.21 4.111E+001 1.502E+001 1.933E+00 480.43 0.34 2.474E+001 -4.477E+000 1.157E+00 487.14 0.43 1.958E+001 -6.734E+000 9.157E+00 533.66 0.18 4.702E+001 -1.977E+001 2.186E+00 580.14 0.37 3.202E+001 1.626E+001 1.513E+00 785.96 1.06 1.164E+001 -7.507E+000 5.412E+00

Nuclide MDA Report 3/27/2017 12:14:11 PM Page 7 Nuclide Energy Yield Line MDA Nuclide MDA Activity Dec. Leve Name (keV) (%) (pCi/gram) (pCi/gram) (pCi/gram) (pCi/gram

+ PB-214 839.07 0.58 2.496E+001 1.44E-001 -5.716E+000 1.169E+00

+ Ra-226 81.07 0.20 2.052E+001 8.24E-001 6.648E+000 9.758E+00 83.79 0.32 1.374E+001 1.001E+001 6.572E+00 186.21* 3.64 8.244E-001 9.157E-001 3.825E-00 U-234 53.20 0.12 4.664E+001 4.66E+001 -1.051E+001 2.194E+00 120.90 0.04 9.589E+001 -2.735E+001 4.541E+00 U-235 72.70 0.12 4.649E+001 3.10E-001 -6.614E+000 2.235E+00 89.96 3.43 1.315E+000 -6.360E-001 6.306E-00 93.35 5.54 7.189E-001 -2.000E-001 3.430E-00 104.82 0.69 4.846E+000 2.526E+000 2.294E+00 105.60 1.31 2.532E+000 1.129E+000 1.198E+00 108.58 0.50 6.257E+000 -4.600E+000 2.952E+00 109.19 1.66 1.948E+000 9.148E-002 9.211E-00 140.76 0.20 1.597E+001 -8.737E+000 7.525E+00 143.76 10.96 3.104E-001 -2.486E-001 1.467E-00 163.36 5.08 7.306E-001 2.220E-001 3.458E-00 182.62 0.39 1.270E+001 -1.435E+001 6.074E+00 194.94 0.63 6.552E+000 -7.414E+000 3.098E+00 202.12 1.08 4.390E+000 2.815E+000 2.089E+00 205.32 5.02 9.600E-001 -4.267E-001 4.568E-00 221.39 0.12 4.021E+001 -6.704E+000 1.905E+00 U-238 63.29 3.70 1.505E+000 9.98E-001 8.855E-001 7.184E-00 92.60 4.23 9.976E-001 2.468E-001 4.773E-00 766.42 0.32 3.857E+001 7.213E+000 1.796E+00 1001.03 0.84 1.550E+001 -3.539E-001 7.114E+00

+ = Nuclide identified during the nuclide identification

  • = Energy line found in the spectrum

> = MDA value not calculated

@ = Half-life too short to be able to perform the decay correction

3/27/2017 12:14:11 LACE Lace v3.2.1 Page 1

        • L I N E A C T I V I T Y C O N S I S T E N C Y E V A L U A T O R ***
===================================================

Analysis using Key Line Activities

===================================================

Filename: C:\\GENIE2K\\CAMFILES\\UNC 2017\\IMC Samples\\IMC-2008\\W6H-IMC-200 Equation used to calculate plot: ln(Ratio) = A + B*ln(Energy) where: Ratio = Activity/KL Activity Notes:

'^' Denotes Key Line energy

  • All uncertainties quoted at 1.96 sigma Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]

K-40 1460.8 ^ 9.56E+000 16.240 Pb-210 46.5 ^ 2.53E+000 41.081 Pb-212 74.8 7.70E-001 32.140 2.923[41.806] 4.34 -0.789 77.1 4.67E-001 31.064 1.771[40.985] [ 0.408]

87.3 8.34E-001 42.403 3.162[50.128]

238.6 ^ 2.64E-001 26.736 1.000[37.810]

3/27/17 12:14:11 LACE - Key Line Results Page 2 Nuclide Energy Activity Activity Ratio[%Uncert] A B (keV) (pCi/gram) %Uncert* [uncert]

BI-214 76.9 1.46E+001 31.194 56.580[49.451] 12.50 -1.949 609.3 ^ 2.59E-001 38.371 1.000[54.265] [ 0.355]

PB-214 74.8 1.37E+000 33.362 4.236[44.373] 5.36 -0.940 77.1 8.23E-001 32.343 2.553[43.612] [ 0.296]

87.3 1.48E+000 43.254 4.583[52.219]

295.2 2.33E-001 47.953 0.722[56.173]

351.9 ^ 3.22E-001 29.256 1.000[41.374]

Ra-226 186.2 ^ 9.16E-001 46.733