Category:Letter
MONTHYEARML23180A1512023-06-29029 June 2023 LLC, Request for Exemption to the Reporting Requirements of 10 CFR 50.46(a)(3) ML21102A3072021-04-15015 April 2021 OEDO-21-00155 - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC, Small Modular Reactor ML21050A4312021-02-19019 February 2021 LLC - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC Small Modular Reactor ML20247J5642020-09-11011 September 2020 Standard Design Approval for the NuScale Power Plant Based on the NuScale 600 Standard Plant Design Certification Application ML20231A8042020-08-28028 August 2020 Final Safety Evaluation Report for the NuScale Standard Plant Design ML20224A4602020-08-25025 August 2020 OEDO-20-00292-Response to the Advisory Committee on Reactor Safeguards Letter on NuScale Power, LLC, Report on the Safety Aspects of the NuScale Small Modular Reactor ML20231A5982020-08-25025 August 2020 OEDO-20-00285_NuScale Area of Focus - Boron Redistribution ML20210M8902020-07-29029 July 2020 Area of Focus - Boron Redistribution ML20195A5872020-07-13013 July 2020 LLC - Submittal of Draft Operator Licensing and Examination Standard for NuScale Small Modular Reactors ML20195C7662020-07-13013 July 2020 LLC Request for Standard Design Approval Based on the NuScale Standard Plant Design Certification Application ML20192A3262020-07-10010 July 2020 LLC, Submittal of Environmental Report: Revision Status ML20198M3932020-07-0202 July 2020 LLC Submittal of Revised Packing Slip for Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1, Dated June 19, 2020 ML20174A3472020-07-0101 July 2020 OEDO-20-00220 - Area of Focus - Probabilistic Risk Assessment and Emergency Core Cooling System Valve Performance ML20184A2872020-07-0101 July 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and General Design Criterion 33, PM-0720-70785, Revision 0 ML20181A4322020-06-22022 June 2020 Final SER for NuScale TR-0516-49416 NON-Loss-of-Coolant Analysis Model, Rev 3 (Letter) ML20181A2702020-06-22022 June 2020 Final SER for NuScale TR-0516-49422 Loss-of-Coolant Analysis Model, Rev 2 (Letter) ML20198M3922020-06-19019 June 2020 LLC - Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1 ML20171A7312020-06-19019 June 2020 LLC, Submittal of Riser Flow Hole Methodology and Associated Changes to Final Safety Analysis Report Incorporating Its Use ML20157A2232020-06-0303 June 2020 Letter to NuScale Requesting -A for TR-0716-50350 ML20150C5172020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled NRC Public Meeting Presentation: Boron Redistribution and Associated Design and DCA Changes, PM-0620-70336, Revision 0 ML20150E1772020-05-29029 May 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Extended Dhrs Operation and RCS Boron Redistribution (Closed Session), PM-0620-70243, Revision 0 ML20150C8812020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and Associated Design and DCA Changes, PM-0620-70244, Revision 0 ML20149M1192020-05-28028 May 2020 LLC Summary of Impacts to Erai 8930 Response and Discussion on the Exemption from General Design Criterion 33 ML20141L8082020-05-20020 May 2020 LLC Submittal of Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 3 ML20141N0122020-05-20020 May 2020 LLC Submittal of Changes to Final Safety Analysis Report, Section 6.2, Containment Systems, Section 6.3, Emergency Core Cooling System, and Technical Report TR-0516-49084, Containment Response Analysis Methodology Technical Report ML20141M7642020-05-20020 May 2020 LLC Submittal of Nuclear Steam Supply System Advanced Sensor Technical Report, TR-0316-22048, Revision 3 ML20141L7872020-05-20020 May 2020 LLC, Submittal of Second Updates to Standard Plant Design Certification Application, Revision 4 ML20141L8162020-05-20020 May 2020 LLC, Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 3 ML20141M1142020-05-20020 May 2020 LLC Submittal of NuScale Instrument Setpoint Methodology Technical Report, TR-0616-49121, Revision 3 ML20141L8042020-05-20020 May 2020 LLC Submittal of Technical Specifications Regulatory Conformance and Development, TR-1116-52011, Revision 4 ML20128J3162020-05-18018 May 2020 OEDO-20-00167 - Response to the ACRS Letter on Combustible Gas Monitoring ML20133K0882020-05-12012 May 2020 LLC, Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution (Closed Session), PM-0420-69512, Revision 0 ML20133J9142020-05-11011 May 2020 LLC Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0420-69511, Revision 0 ML20112F4552020-05-0101 May 2020 LLC, Design Certification Application Phases 5 and 6 Review Status ML20107F8492020-05-0101 May 2020 OEDO-2000140 - NuScale Area of Focus - Helical Tube Steam Generator Design ML20104A0792020-04-27027 April 2020 OEDO-20-00115 - Safety Evaluation Report for Topical Report TR-0516-49416, Revision 2, Non-Loss-of-Coolant Accident Analysis Methodology ML20099H0802020-04-0808 April 2020 LLC - Submittal of Presentation Materials Entitled NRC Public Meeting: Revisions to Nuscale'S EPZ Sizing Methodology Topical Report, PM-0420-69598, Revision 0 ML20098G2372020-04-0707 April 2020 Nuscale Power, LLC Submittal of Remaining Closure Items for the Emergency Core Cooling System Valve Failure Mode Effects Analysis Audit Items ML20097F1922020-04-0606 April 2020 Nuscale Power, LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: Nuscale Topic - Hydrogen/Oxygen Monitoring, PM-0420-69518, Revision 0 ML20094H6742020-04-0303 April 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation NuScale Topic-Probabilistic Risk Assessment with a Focus on Emergency Core Cooling System Analysis PM-0420-69559, Revision 0 ML20092L8992020-04-0101 April 2020 LLC - Submittal of Updates to Standard Plant Design Certification Application, Revision 4 ML20072M6682020-03-30030 March 2020 Response to NuScale Letter Dated February 24, 2020, on Planned SDA Application Content ML20072H3332020-03-0909 March 2020 LLC - Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0320-69218, Revision 0 ML20057D9002020-03-0606 March 2020 Submittal of Errata to Final SE for NuScale Power, LLC TR-1010-859-NP-A, Quality Assurance Program Description for the NuScale Power Plant ML20062F7262020-03-0505 March 2020 Request for Withholding Information from Public Disclosure for Nuscale Power, LLC Letter Public ML20069A1572020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Rod Ejection Accident Methodology, PM-0320-69146, Revision 0 ML20069A1772020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Non-Loss-of-Coolant Accident, PM-0320-69141, Revision 0 ML20069A9632020-03-0404 March 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report, Loss-of-Coolant Accident Evaluation Model, PM-0320-69138, Revision 0 ML20066G2802020-03-0303 March 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topic - Hydrogen Monitoring, PM-0220-69071, Revision 0 ML20066G2882020-02-28028 February 2020 LLC Submittal of Presentation Materials Titled ACRS Full Committee Presentation: NuScale - Steam Generator Design (Closed Session), PM-0220-69053, Revision 0 2023-06-29
[Table view] Category:Response to Request for Additional Information (RAI)
MONTHYEARRAIO-0420-69855, LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification2020-04-30030 April 2020 LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification ML19332A1202019-11-27027 November 2019 LLC Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19304B4712019-10-31031 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 466 (Erai No. 9482) on the NuScale Design Certification Application ML19296D8052019-10-23023 October 2019 LLC Response to NRC Request for Additional Information No. 526 (Erai No. 9719) on the NuScale Design Certification Application ML19283E5302019-10-10010 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19260G7352019-10-0707 October 2019 Summary of Public Meeting with NuScale to Discuss Response to RAI 9681 ML19266A5872019-09-23023 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 518 (Erai No. 9659) on the NuScale Design Certification Application ML19262G9742019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Tier 1, Section 3.11, Reactor Building and Section 3.13, Control Building, and Tier 2, Section 3.8.4, Design of Category I Structure and Section 14.3, Certified ... ML19262G5762019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Section 14.2, Initial Plant Test Program, Table 14.2-2, Pool Cleanup Systems Test #2, and Table 14.2-50, Module Assembly Equipment Test #50 ML19259B8102019-09-16016 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19259A0922019-09-16016 September 2019 LLC Response to NRC Request for Additional Information No. 525 (Erai No. 9705) on the NuScale Design Certification Application ML19238A3722019-08-26026 August 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19238A3662019-08-23023 August 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19215A0032019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19215A0062019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 441 (Erai No. 9485) on the NuScale Design Certification Application ML19212A7622019-07-31031 July 2019 LLC Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19212A3752019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 483 (Erai No. 9516) on the NuScale Design Certification Application ML19212A7992019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19212A6892019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19210D1592019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19210D7342019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 520 (Erai No. 9642) on the NuScale Design Certification Application ML19210E1462019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19207B3812019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19207A5342019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19207B8522019-07-25025 July 2019 LLC Response to NRC Request for Additional Information No. 194 (Erai No. 8884) on the NuScale Design Certification Application ML19203A3152019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19203A3212019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 333 (Erai No. 9282) on the NuScale Design Certification Application ML19203A3092019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 54 (Erai No. 8837) on the NuScale Design Certification Application ML19203A3422019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 154 (Erai No. 8938) on the NuScale Design Certification Application ML19200A2482019-07-19019 July 2019 LLC Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19200A2082019-07-19019 July 2019 LLC - Response to NRC Request for Additional Information No. 524 (Erai No. 9691) on the NuScale Design Certification Application ML19199A1172019-07-18018 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19198A3252019-07-17017 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 249 (Erai No. 9135) on the NuScale Design Certification Application ML19196A3682019-07-15015 July 2019 LLC Response to NRC Request for Additional Information No. 516 (Erai No. 9647) on the NuScale Design Certification Application ML19191A2202019-07-10010 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19184A6152019-07-0303 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19176A5802019-06-25025 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19170A3702019-06-19019 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19168A2442019-06-17017 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19164A1452019-06-13013 June 2019 LLC - Submittal of Containment Response Analysis Methodology Technical Report, TR-0516 -49 08 4, Revision 1 ML19157A3262019-06-0606 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19154A6222019-06-0303 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19154A6052019-06-0303 June 2019 LLC Response to NRC Request for Additional Information No. 514 (Erai No. 9645) on the NuScale Design Certification Application ML19151A8372019-05-31031 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 377 (Erai No. 9380) on the NuScale Design Certification Application ML19140A4592019-05-20020 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19137A2902019-05-17017 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 156 (Erai No. 9031) on the NuScale Design Certification Application ML19137A2872019-05-15015 May 2019 LLC Response to NRC Request for Additional Information No. 519 (Erai No. 9656) on the NuScale Design Certification Application ML19126A2942019-05-0606 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 26 (Erai No. 8840) on the NuScale Design Certification Application ML19122A5092019-05-0202 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 494 (Erai No. 9548)on the Design Certification Application ML19121A6002019-05-0101 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on Design Certification Application 2020-04-30
[Table view] |
Text
RAIO-0319-64956 March 25, 2019 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Supplemental Response to NRC Request for Additional Information No. 256 (eRAI No. 9161) on the NuScale Design Certification Application
REFERENCES:
- 1. U.S. Nuclear Regulatory Commission, "Request for Additional Information No. 256 (eRAI No. 9161)," dated October 13, 2017
- 2. NuScale Power, LLC Response to NRC "Request for Additional Information No. 256 (eRAI No.9161)," dated August 30, 2018
- 3. NuScale Power, LLC Supplemental Response to "NRC Request for Additional Information No. 256 (eRAI No. 9161)" dated November 19, 2018 The purpose of this letter is to provide the NuScale Power, LLC (NuScale) supplemental response to the referenced NRC Request for Additional Information (RAI).
The Enclosure to this letter contains NuScale's supplemental response to the following RAI Question from NRC eRAI No. 9161:
11.01-1 This letter and the enclosed response make no new regulatory commitments and no revisions to any existing regulatory commitments.
If you have any questions on this response, please contact Carrie Fosaaen at 541-452-7126 or at cfosaaen@nuscalepower.com.
Sincerely, Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Gregory Cranston, NRC, OWFN-8H12 Samuel Lee, NRC, OWFN-8H12 Getachew Tesfaye, NRC, OWFN-8H12 : NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9161 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0319-64956 :
NuScale Supplemental Response to NRC Request for Additional Information eRAI No. 9161 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
Response to Request for Additional Information Docket No.52-048 eRAI No.: 9161 Date of RAI Issue: 10/13/2017 NRC Question No.: 11.01-1 Regulatory Requirements/Guidance 10 CFR 52.47(a)(5) requires applicants to identify the kinds and quantities of radioactive materials expected to be produced in the operation and the means for controlling and limiting radiation exposures. Radioactive materials are released as liquid and gaseous effluents and are generated in plant systems during normal reactor operations resulting in doses to workers and members of the public. 10 CFR Part 20, Appendix I to 10 CFR Part 50, and 40 CFR Part 190 specify the annual dose limits to workers and members of the public, and the As Low As is Reasonably Achievable numerical objectives in the design of radwaste systems for controlling and limiting liquid and gaseous effluent releases.
The Design Specific Review Standard (DSRS) Acceptance Criteria section for NuScale, DSRS Section 11.1, Coolant Source Terms, states when the applicants calculation technique or any source term parameters differ from that given in NUREG-0017 or ANSI/ANS 18.1-1999, they should be described with sufficient detail, and the basis of the alternate method and model parameters should be provided to allow the staff to conduct an independent evaluation. DSRS Sections 11.2, Liquid Waste Management System, and 11.3, Gaseous Waste Management System, describe that the calculated annual total quantity of radioactive materials released from each reactor will not result in exceeding the annual exposure pathway doses from liquid and gaseous effluents in Appendix I to 10 CFR Part 50; annual dose limits in 10 CFR 20.1301; and annual liquid and gaseous effluent concentration limits in Table 2, Columns 1 and 2 of Appendix B to 10 CFR Part 20. Further, DSRS Section 12.2, Radiation Sources, states that applications should contain the methods, models, and assumptions used as the bases for all sources described.
NuScale Nonproprietary
Key Issue: NuScale is pursuing an alternate approach for developing realistic liquid and gaseous effluent release source terms during normal operations from that endorsed by NRC in its current guidance. Any differences from the endorsed approach must be identified and justified.
Design certification application content:
NuScale Technical Report TR-1116-52065-NP Rev. 0, Effluent Release (GALE Replacement)
Methodology and Results, provides a proposed alternative methodology for determining the realistic fuel failure fraction of 0.000028 (0.0028 percent (%) or 28 parts per million (ppm))
applied in fundamental first principle calculations of liquid and gaseous effluent source terms expected from normal operating conditions for the NuScale design. This realistic fuel failure fraction is based on a literature search as there is no operating experience or data available for performance of the shorter-in-length AREVA M5 fuel in a first-of-a-kind small modular reactor design. From the staffs review of the literature referenced in TR-1116-52065-NP Rev. 0; Chapter 11, Radioactive Waste Management of the Design Control Document (DCD); and information obtained independently by the staff, there is an insufficient technical bases and justification to support the realistic failed fuel fraction in TR-1116-52065-NP Rev. 0.
The staff requests that NuScale provide the following information for its review of the realistic failed fuel fraction to evaluate compliance with the applicable NRC requirements:
- 1. NuScale needs to provide a technical basis that clearly identifies and describes the fuel failure methodology (e.g., how fuel failure rate is evaluated using an approach such as the outage method). As part of its evaluation of the technical bases, the staff needs to review and confirm key parameters, values and assumptions used in calculating a conservative realistic failed fuel fraction appropriate for determining reactor coolant system (RCS) activity concentrations. Examples of parameters and values include the number of U.S. PWRs determined to be representative, core/assembly size, number of failed pins/rods, number of pins/rods and assemblies in refueling cycle, and total number of rods in the entire core that have been refueled in that year for the range of years considered. Examples of assumptions used in calculating a conservative realistic failed fuel fraction may include a maximum value or average value plus two sigma that bounds the realistic failed fuel fraction. The staff also needs to be provided for its review and evaluation the Electric Power Research Institute (EPRI) source data, other associated information, and quality documentation supporting the calculation of the realistic failed fuel fraction basis.
NuScale Nonproprietary
- 2. In NuScale Technical Report TR-1116-52065-NP Rev. 0, International Atomic Energy Agency, Review of Fuel Failures in Water Cooled Reactors, IAEA Nuclear Energy Series No. NF-T-2.1, June 2010 (Reference 7.2.9) states that there are different methods of fuel failure rate evaluation used by different utilities, fuel vendors and organizations make fuel failure analysis and identification of general tendencies in fuel performance evaluation difficult. It further describes that EPRI uses the fuel assembly failure rate method which may underestimate the defect rate by a factor of about three to five. For example, Table 3.3 in IAEA NF-T-2.1 shows that for U.S. PWRs from 1994 through 2006 there is a factor of 5 underestimation (non-conservativism) in comparing old (core) method of 25.8 parts per million (ppm) and new (reload) method of 131.6 ppm for fuel failure rates.
Provide sufficient detail to identify and justify the failed fuel methodology (i.e., fuel failure rate evaluation) applied in determining the RCS activity concentrations for the NuScale design.
- 3. NuScale Technical Report TR-1116-52065-NP Rev. 0, Section 5.2, US Pressurized Water Reactor Fuel Failure History discusses fuel failure fractions and suggests a correlation to ANSI/ANS-18.1- 1999, NUREG-0017 Rev. 1, PWR-GALE08, and PWR-GALE09.
The ANSI/ANS-18.1-1999 voluntary standard (Reference 7.2.2) and NUREG-0017 Rev. 1 guidance (Reference 7.2.1) do not specify any failed fuel fraction, fuel failure methodology, or discuss the representativeness and quality of these data. Moreover, interim versions of PWR-GALE08 and PWR- GALE09 in Geelhood, K.J. and J.P. Rishel, Applicability of GALE-86 Codes to Integral Pressurized Water Reactor Designs, PNNL-21386, May 2012 (Reference 7.2.3), and Geelhood, K.J., Benchmarking of GALE-09 Release Predictions Using Site Specific Data from 2005 to 2010, PNNL- 22076, November 2012 (Reference 7.2.19) are not endorsed by the NRC.
Given that ANSI/ANS-18.1-1999 and NUREG-0017 Rev. 1 do not provide sufficient information to support a realistic failed fuel fraction basis, and that PWR-GALE08 and PWR-GALE09 are not endorsed by the NRC, provide sufficient detail and justification of how fuel failure rates can be correlated to ANSI/ANS-18.1-1999, NUREG-0017 Rev. 1, PWR-GALE08 and PWR-GALE09, and are appropriate for determining RCS activity concentrations for the NuScale design.
- 4. NuScale Technical Report TR-1116-52065-NP Rev. 0, Appendix A, Table A-6, Fuel failure data for U.S. PWRs with zirconium-alloy cladding provides failed fuel fractions for Sources NuScale Nonproprietary
and References from the early 1970s through 2010. Figure 5-2, Fuel failure data for zirconium-alloy clad U.S. pressurized water reactors plots fuel failure fractions for zirconium-alloy clad U.S. PWRs from 1975 through 2010 from various sources. Table 5-1, Fuel failure values shows Minimum (Rods/Million), Maximum (Rods/Million), and Average (Rods/Million) values for three Date Ranges (1996-2000, 2001-2005, 2006-2010), in which the realistic fuel failure fraction of 0.000028 (0.0028% or 28 ppm) is shown as the maximum value for date ranges 2001-2005.
The NuScale realistic fuel failure fraction of 0.000028 (0.0028% or 28 ppm) is determined from EPRI source data in 2001 and Executive Summary - The Path to Zero Defects: EPRI Fuel Reliability Guidelines, 2008 (Reference 7.2.13). This two page Executive Summary contains a figure (bar graph) showing EOC (end of cycle) from 1980 through 2007 on the x-axis, but there is no unit label on the y-axis to identity what the values ranging from 0 to 300 represent.
- a. Provide the y-axis unit label (e.g., number of failed pins/rods identified in refueling cycle for that year;
- b. Identify the fuel failure methodology (e.g., core, outage, or reload) applied for each year from 1980 through 2007;
- c. Provide the EPRI source data, associated information, and quality documentation used to extrapolate the maximum value (around 95 with no expressed unit label) in 2001 for U.S. PWRs in calculating the realistic fuel failure fraction; and
- d. Provide sufficient detail and justification of how the tables, figures, and fuel failure methodology applied establishes an appropriate basis for determining RCS activity concentrations for the NuScale design.
- 5. In NuScale Technical Report TR-1116-52065-NP Rev. 0, the staff notes that conference presentations such as the International Atomic Energy Agency, Results of the IAEA Study of Fuel Failures in Water Cooled Reactors in 2006-2010, Presentation at Technical Working Group on Fuel Performance and Technology (TWGFPT) Meeting, April 24, 2012 (Reference 7.2.14); and U.S. Nuclear Regulatory Commission, Nuclear Fuel Performance, Office of NuScale Nonproprietary
Nuclear Regulatory Research and Office of Nuclear Reactor Regulation Presentation, February 24, 2005 (Reference 7.2.18) are intended for information purposes only.
Provide sufficient detail and justification of how this information (conference presentations) can be used as the basis for licensing and for determining RCS activity concentrations for the NuScale design.
- 6. NuScale needs to revise the relevant sections, tables, and figures in DCD Chapters 11 and 12 and NuScale Technical Report TR-1116-52065-NP Rev. 0 related to the realistic failed fuel fraction discussions, and provide markups to include this revised information.
NuScale Response:
This supplemental response to RAI 9161 is provided to document the changes to FSAR Table 11.1-1 "Maximum Core Isotopic Inventory." These changes were incorporated into revision 2 of the DCA to reflect the actual core isotopic inventory that was utilized in the development of the Chapter 11 and 12 analyses.The previous version of Table 11.1-1 did not reflect the actual inventory used for these analyses.
Impact on DCA:
FSAR Table 11.1-1 has been revised as described in the response above and as shown in the markup provided in this response.
NuScale Nonproprietary
NuScale Final Safety Analysis Report Source Terms Table 11.1-1: Maximum Core Isotopic Inventory Nuclide Core Inventory (Ci) Nuclide Core Inventory (Ci)
Noble Gases Other Fission Products Kr83m 4.7E+05 Y92 4.9E+06 Kr85m 9.7E+05 Y93 5.8E+06 Kr85 1.3E+05 Zr97 7.2E+06 Kr87 1.9E+06 Nb95 6.8E+06 Kr88 2.4E+06 Mo99 8.1E+06 Kr89 3.0E+06 Mo101 7.9E+06 Xe131m 6.0E+04 Tc99m 7.2E+06 Xe133m 2.9E+05 Tc99 2.1E+02 Xe133 9.0E+06 Ru103 8.9E+06 Xe135m 2.1E+06 Ru105 7.2E+06 Xe135 3.5E+06 Ru106 5.7E+06 Xe137 7.9E+06 Rh103m 8.8E+06 Xe138 7.4E+06 Rh105 6.8E+06 Halogens Rh106 6.1E+06 Br82 2.6E+04 Ag110 2.3E+06 Br83 4.6E+05 Sb124 1.3E+04 Br84 7.7E+05 Sb125 1.1E+05 Br85 9.6E+05 Sb127 5.3E+05 I129 5.4E-01 Sb129 1.5E+06 I130 2.7E+05 Te125m 2.7E+04 I131 4.6E+06 Te127m 8.7E+04 I132 6.6E+06 Te127 5.3E+05 I133 8.9E+06 Te129m 2.5E+05 I134 9.9E+06 Te129 1.5E+06 I135 8.5E+06 Te131m 9.9E+05 Rubidium, Cesium Te131 3.9E+06 Rb86m 2.0E+03 Te132 6.4E+06 Rb86 1.6E+04 Te133m 4.1E+06 Rb88 2.5E+06 Te134 7.6E+06 Rb89 3.3E+06 Ba137m 1.6E+06 Cs132 3.2E+02 Ba139 7.7E+06 Cs134 2.7E+06 Ba140 7.4E+06 Cs135m 3.2E+04 La140 7.8E+06 Cs136 5.9E+05 La141 7.0E+06 Cs137 1.6E+06 La142 6.6E+06 Cs138 8.1E+06 Ce141 7.0E+06 Other Fission Products Ce143 6.4E+06 P32 7.2E+02 Ce144 5.9E+06 Co57 5.3E+00 Pr143 6.2E+06 Sr89 3.4E+06 Pr144 5.9E+06 Sr90 1.1E+06 Np239 1.2E+08 Sr91 4.4E+06 C14 2.1E+01 Sr92 4.9E+06 H3 2.0E+04 Y90 1.2E+06 Y91m 2.6E+06 Y91 4.5E+06 Tier 2 11.1-9 Draft Revision 2
NuScale Final Safety Analysis Report Source Terms RAI 11.01-2 Table 11.1-2: Maximum Core Isotopic Inventory Nuclide Core Inventory (Ci) Nuclide Core Inventory (Ci)
Noble Gases Other Fission Products Kr83m 7.289E+05 Y92 8.103E+06 Kr85m 1.698E+06 Y93 8.584E+06 Kr85 1.339E+05 Zr95 8.547E+06 Kr87 3.478E+06 Zr97 8.288E+06 Kr88 4.662E+06 Nb95 8.510E+06 Kr89 5.994E+06 Mo99 8.658E+06 Xe131m 5.994E+04 Mo101 7.881E+06 Xe133m 2.871E+05 Tc99m 7.622E+06 Xe133 9.509E+06 Ru103 8.843E+06 Xe135m 2.098E+06 Ru105 7.215E+06 Xe135 4.958E+06 Ru106 5.698E+06 Xe137 8.547E+06 Rh103m 8.769E+06 Xe138 8.621E+06 Rh105 6.771E+06 Halogens Rh106 6.142E+06 Br82 2.568E+04 Ag110m 6.475E+04 Br83 7.289E+05 Sb124 1.302E+04 Br84 1.310E+06 Sb125 1.143E+05 Br85 1.691E+06 Sb127 5.328E+05 I129 5.365E-01 Sb129 1.532E+06 I130 2.683E+05 Te125m 2.697E+04 I131 4.662E+06 Te127m 8.658E+04 I132 6.660E+06 Te127 5.254E+05 I133 9.546E+06 Te129m 2.498E+05 I134 1.092E+07 Te129 1.462E+06 I135 8.991E+06 Te131m 9.916E+05 Rubidium, Cesium Te131 3.922E+06 Rb86m 2.013E+03 Te132 6.438E+06 Rb86 1.595E+04 Te133m 4.625E+06 Rb88 4.699E+06 Te134 9.546E+06 Rb89 6.253E+06 Ba137m 1.558E+06 Cs132 3.230E+02 Ba139 8.806E+05 Cs134 2.671E+06 Ba140 8.510E+06 Cs135m 3.193E+04 La140 8.547E+06 Cs136 5.883E+05 La141 8.066E+06 Cs137 1.635E+06 La142 7.955E+06 Cs138 9.213E+06 Ce141 7.955E+06 Other Fission Products Ce143 8.103E+06 P32 7.622E+02 Ce144 6.586E+06 Co57 5.254E+00 Pr143 7.844E+06 Ni63 4.144E+01 Pr144 6.623E+06 Sr89 5.957E+06 Np239 1.288E+08 Sr90 1.129E+06 Sr91 7.770E+06 Sr92 7.992E+06 Y90 1.158E+06 Y91m 4.588E+06 Y91 7.363E+06 Tier 2 11.1-10 Draft Revision 2