RA-18-0248, Response to Request for Additional Information Regarding License Amendment Request for Emergency Action Level Scheme Change

From kanterella
(Redirected from ML18351A052)
Jump to navigation Jump to search

Response to Request for Additional Information Regarding License Amendment Request for Emergency Action Level Scheme Change
ML18351A052
Person / Time
Site: Harris 
Issue date: 12/17/2018
From: Hamilton T
Duke Energy Progress
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA-18-0248
Download: ML18351A052 (41)


Text

Tanya M. Hamilton Vice President Harris Nuclear Plant 5413 Shearon Harris Rd New Hill, NC 27562-9300 10 CFR 50.90 December 17, 2018 Serial: RA-18-0248 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Shearon Harris Nuclear Power Plant, Unit 1 Docket No. 50-400 Renewed License No. NPF-63

Subject:

Response to Request for Additional Information Regarding License Amendment Request for Emergency Action Level Scheme Change Ladies and Gentlemen:

By application dated August 13, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18226A022), Duke Energy Progress, LLC (Duke Energy),

requested approval for an emergency action level (EAL) scheme change for Shearon Harris Nuclear Power Plant, Unit 1 (HNP). The Nuclear Regulatory Commission (NRC) staff reviewed the request and determined that additional information is needed to complete their review. Duke Energy received a request for additional information (RAI) from the NRC staff through electronic mail on November 19, 2018 (ADAMS Accession No. ML18332A439), with a required response date of December 27, 2018. to this letter provides Duke Energys response to the RAI. The proposed changes to the impacted pages of the EAL Technical Basis Document provided in the application dated August 13, 2018, were updated to incorporate changes in response to the RAI. Enclosure 2 provides the clean version of the HNP EAL Technical Bases Document impacted pages.

Enclosures 3 provides the markup version of the HNP EAL Technical Bases Document impacted pages. Enclosure 4 provides a markup version of the HNP EAL Wallcharts for the proposed changes.

In accordance with 10 CFR 50.91(b), HNP is providing the state of North Carolina with a copy of this response.

This letter does not contain any regulatory commitments.

Should you have any questions regarding this submittal, please contact Arthur Zaremba at (980) 373-2062.

U.S. Nuclear Regulatory Commission Serial RA-18-0248 I declare under penalty of perjury that the foregoing is true and correct. Executed on December I 1 1 2018.

Sincerely, Tanya M. Hamilton

Enclosures:

1. Response to Request for Additional Information Page 2 of 2
2. Proposed Harris Nuclear Plant Emergency Action Level Technical Bases Document Changes! EP-EAL (Clean)
3. Proposed Harris Nuclear Plant Emergency Action Level Technical Bases Document Changes, EP-EAL (Markup)
4. Proposed Harris Nuclear Plant Emergency Action Level Wallchart Changes (Markup) cc:

J. Zeiler, NRC Sr. Resident Inspector, HNP W. L. Cox, 111 1 Section Chief, N.C. DHSR M. Barillas, NRC Project Manager, HNP NRC Regional Administrator, Region II

U.S. Nuclear Regulatory Commission Page 2 of 2 Serial RA-18-0248 I declare under penalty of perjury that the foregoing is true and correct. Executed on December, 2018.

Sincerely, Tanya M. Hamilton

Enclosures:

1.

Response to Request for Additional Information 2.

Proposed Harris Nuclear Plant Emergency Action Level Technical Bases Document Changes, EP-EAL (Clean) 3.

Proposed Harris Nuclear Plant Emergency Action Level Technical Bases Document Changes, EP-EAL (Markup) 4.

Proposed Harris Nuclear Plant Emergency Action Level Wallchart Changes (Markup) cc:

J. Zeiler, NRC Sr. Resident Inspector, HNP W. L. Cox, III, Section Chief, N.C. DHSR M. Barillas, NRC Project Manager, HNP NRC Regional Administrator, Region II

U.S. Nuclear Regulatory Commission Serial RA-18-0248, Enclosure 1 SERIAL RA-18-0248 ENCLOSURE 1 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 DOCKET NO. 50-400 RENEWED LICENSE NUMBER NPF-63

U.S. Nuclear Regulatory Commission Page 1 of 2 Serial RA-18-0248, Enclosure 1 By application dated August 13, 2018 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML18226A022), Duke Energy Progress, LLC (Duke Energy),

requested approval for an emergency action level (EAL) scheme change for Shearon Harris Nuclear Power Plant, Unit 1 (HNP). The Nuclear Regulatory Commission (NRC) staff reviewed the request and determined that additional information is needed to complete their review. Duke Energy received a request for additional information (RAI) from the NRC staff through electronic mail on November 19, 2018 (ADAMS Accession No. ML18332A439), with a required response date of December 27, 2018.

Duke Energy provides the following response to the RAI regarding the license amendment request. The proposed changes to the impacted pages of the EAL Technical Basis Document provided in the application dated August 13, 2018, were updated to incorporate changes in response to the RAI. Enclosure 2 provides the clean version of the HNP EAL Technical Bases Document impacted pages. Enclosures 3 provides the markup version of the HNP EAL Technical Bases Document impacted pages. Enclosure 4 provides a markup version of the HNP EAL Wallcharts for the proposed changes. There are no changes to the information provided in the significant hazards consideration within the application submitted on August 13, 2018, because of this RAI response.

HNP RAI-1:

Emergency action level (EAL) threshold levels for CS1.3 and CG1.2 [CS1 and CG1] are applicable in Modes 5 and 6. However, page 5 of Enclosure 5, Calculation for Radiation Monitor Readings for Core Uncovery during Refueling, provides that the CG1.2 radiation monitor threshold value is predicated on the loss of water above the core during refueling shutdown with the reactor vessel head removed. EAL CS1.3 uses the same radiation value as EAL CG1.2. No radiation monitor threshold values were provided for Modes 5 or 6 with the head installed.

a. Although Enclosure 5 provides that the radiation monitor threshold is predicated on a loss of water with the reactor vessel head removed, there was no note or other guidance provided in the threshold values for EALs CS1.3 or CG1.2, which indicated that the threshold value is based on the reactor vessel head being removed. Please explain how an inaccurate or delayed classification would not occur if EALs CS1.3 and CG1.2 do not clearly indicate that the threshold values are based on the reactor vessel head being removed.
b. The staff could not determine if an accurate containment radiation threshold value, corresponding to reactor vessel level being approximately at the top of active fuel, could be determined with the reactor vessel head installed. Please explain why a containment radiation level threshold value indicating water level at the top of active fuel was not provided with the reactor vessel head installed.

HNP Response:

a. A change has been made to the EAL basis for EALs CS1.3 and CG1.2 to provide clarification regarding the calculation assumptions used to establish the radiation monitor threshold value. The following statement has been added to EAL basis for EALs CS1.3 and CG1.2, as shown in Enclosures 2 and 3:

A calculation shows that if these radiation monitors reach and exceed 2.6E+04 mR/hr when the reactor vessel head is removed, with RCS [reactor coolant system] water level indication

U.S. Nuclear Regulatory Commission Page 2 of 2 Serial RA-18-0248, Enclosure 1 unavailable for greater than 30 minutes, then a loss of inventory with potential to uncover the core is likely to have occurred.

b. The other initiating conditions of EALs CS1.3 and CG1.2 for core uncovery, which are an unplanned increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery or erratic source range monitor indication, remain available to provide the basis for the declaration of EALs CS1.3 and CG1.2 when the plant is in Modes 5 or 6 with the reactor vessel head installed. Therefore, a containment radiation level threshold value indicating water level at the top of active fuel with the reactor vessel head installed was not provided for EALs CS1.3 and CG1.2.

HNP RAI-2:

The Table F-1 Fission Product Barrier Threshold Matrix for Containment Radiation provides the radiation monitors that should be used to assess the fission product barriers. As proposed, two separate types of monitors with different ranges will be used to assess containment radiation.

The associated values to assess Table F-1 threshold values for containment radiation are provided on Table F-2, Containment Radiation. Since Table F-2 does not include which radiation monitors should be used, and uses both milli-rem and rem (which is only provided in the title block), there is a potential for either a delayed or inaccurate classification. Please explain how the proposed Table F-1 and F-2 will not cause either a potential delay or an inaccurate classification of fission product barriers based on containment radiation values or revise accordingly.

HNP Response:

A change has been made to Table F-2 that includes the radiation monitor information and the units of measurement for the radiation monitor values shown in the table. The units of measurement in the Table F-2 are consistent with the units of measurement indicated by the radiation monitors. This change is shown in Enclosures 2, 3, and 4.

U.S. Nuclear Regulatory Commission Serial RA-18-0248, Enclosure 2 SERIAL RA-18-0248 ENCLOSURE 2 PROPOSED HARRIS NUCLEAR PLANT EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT CHANGES, EP-EAL (CLEAN)

SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 DOCKET NO. 50-400 RENEWED LICENSE NUMBER NPF-63

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 70 of 220 Category:

C - Cold Shutdown / Refueling System Malfunction Subcategory:

1 - RCS Level Initiating Condition: Loss of RCS inventory affecting core decay heat removal capability EAL:

CS1.3 Site Area Emergency RCS water level cannot be monitored for 30 min. (Note 1)

AND Core uncovery is indicated by any of the following:

  • UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery
  • A Containment Ventilation Isolation Radiation Monitor > 2.6E+04 mR/hr (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB)
  • Erratic source range monitor indication Note 1:

The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Table C-1 Sumps / Tanks

  • RMWST
  • Recycle Holdup Tank Mode Applicability:

5 - Cold Shutdown, 6 - Refueling Definition(s):

UNISOLABLE - An open or breached system line that cannot be isolated, remotely or locally.

UNPLANNED - A parameter change or an event that is not 1) the result of an intended evolution or 2) an expected plant response to a transient. The cause of the parameter change or event may be known or unknown.

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 71 of 220 Basis:

In this EAL, all RCS water level indication would be unavailable for greater than 30 minutes, and the RCS inventory loss must be detected by indirect leakage indications. Sump level increases must be evaluated against other potential sources of leakage. If the make-up rate to the RCS unexplainably rises above the pre-established rate, a loss of RCS inventory may be occurring even if the source of the leakage cannot be immediately identified. Sumps and tanks where RCS leakage may accumulate are listed in listed in Table C-1(ref. 1, 2).

In the Refueling Mode, as water level in the reactor vessel lowers, the dose rate above the core will increase. The dose rate due to this loss of water shielding from the reactor cavity will result in indications on the Containment Ventilation Isolation (CVI) area radiation monitors. A calculation (ref. 4) shows that if these radiation monitors reach and exceed 2.6E+04 mR/hr when the reactor vessel head is removed, with RCS water level indication unavailable for greater than 30 minutes, then a loss of inventory with potential to uncover the core is likely to have occurred.

Post-TMI accident studies indicated that the installed PWR nuclear instrumentation will operate erratically when the core is uncovered and that this should be used as a tool for making such determinations.

This IC addresses a significant and prolonged loss of RCS inventory control and makeup capability leading to IMMINENT fuel damage. The lost inventory may be due to a RCS component failure, a loss of configuration control or prolonged boiling of reactor coolant.

These conditions entail major failures of plant functions needed for protection of the public and thus warrant a Site Area Emergency declaration.

Following an extended loss of core decay heat removal and inventory makeup, decay heat will cause reactor coolant boiling and a further reduction in reactor vessel level. If RCS level cannot be restored, fuel damage is probable.

The 30-minute criterion is tied to a readily recognizable event start time (i.e., the total loss of ability to monitor level), and allows sufficient time to monitor, assess and correlate reactor and plant conditions to determine if core uncovery has actually occurred (i.e., to account for various accident progression and instrumentation uncertainties). It also allows sufficient time for performance of actions to terminate leakage, recover inventory control/makeup equipment and/or restore level monitoring.

The inability to monitor RCS level may be caused by instrumentation and/or power failures, or water level dropping below the range of available instrumentation. If water level cannot be monitored, operators may determine that an inventory loss is occurring by observing changes in sump and/or tank levels. Sump and/or tank level changes must be evaluated against other potential sources of water flow to ensure they are indicative of leakage from the RCS.

EAL values should be determined with a margin sufficient to ensure that an accurate monitor reading is available. For example, an EAL monitor reading might be set at 90% to 95% of the highest accurate monitor reading.

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 72 of 220 A single calculated radiation monitor reading does not represent core uncovery for all event scenarios due to multiple variables that can affect the source term (i.e., number of fuel assemblies in the core, fuel burn up in each assembly, and time after shutdown). Therefore, consideration has been given so that the threshold value of > 2.6E+04 mR/hr on the CVI radiation monitors will be low enough to be a valid indication of fuel uncovery, but high enough so that inadvertent classifications are not caused by maintenance events or other conditions that may increase radiation levels without a coincident loss of reactor vessel water level (ref. 4).

HNP utilizes CVI area radiation monitors RM-1CR-3561A-SA, 1RM-1CR-3561B-SB, RM-1CR-3561C-SA, and RM-1CR-3561D-SB for evaluating conditions in containment. The sensitivity and location of these monitors allows them to detect significant changes in the loss of water shielding from the reactor cavity, which can be used to detect core uncovery.

This EAL addresses concerns raised by Generic Letter 88-17, Loss of Decay Heat Removal; SECY 91-283, Evaluation of Shutdown and Low Power Risk Issues; NUREG-1449, Shutdown and Low-Power Operation at Commercial Nuclear Power Plants in the United States; and NUMARC 91-06, Guidelines for Industry Actions to Assess Shutdown Management.

Escalation of the emergency classification level would be via IC CG1 or RG1.

HNP Basis Reference(s):

1. GP-001, Reactor Coolant System Fill and Vent Mode 5
2. GP-008, Draining the Reactor Coolant System
3. GP-009, Refueling Cavity Fill, Refueling and Drain of the Refueling Cavity Modes 5-6-5
4. CSD-EP-HNP-0101-06, Radiation Monitor Readings for Core Uncovery during Refueling
5. NEI 99-01 CS1

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 76 of 220 Category:

C - Cold Shutdown / Refueling System Malfunction Subcategory:

1 - RCS Level Initiating Condition: Loss of RCS inventory affecting fuel clad integrity with containment challenged EAL:

CG1.2 General Emergency RCS level cannot be monitored for 30 min. (Note 1)

AND Core uncovery is indicated by any of the following:

  • UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery
  • A Containment Ventilation Isolation Radiation Monitor > 2.6E+04 mR/hr (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB)
  • Erratic source range monitor indication AND Any Containment Challenge indication, Table C-2 Note 1:

The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 6:

If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Table C-1 Sumps / Tanks

  • RMWST
  • Recycle Holdup Tank Table C-2 Containment Challenge Indications
  • CONTAINMENT CLOSURE not established (Note 6)
  • UNPLANNED rise in Containment pressure

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 77 of 220 Mode Applicability:

5 - Cold Shutdown, 6 - Refueling Definition(s):

CONTAINMENT CLOSURE - The procedurally defined actions taken to secure containment and its associated structures, systems, and components as a functional barrier to fission product release under shutdown conditions. As applied to HNP, Containment Closure is established when containment penetration closure is established in accordance with Technical Specifications 3/4.9.4.

UNISOLABLE - An open or breached system line that cannot be isolated, remotely or locally.

UNPLANNED - A parameter change or an event that is not 1) the result of an intended evolution or 2) an expected plant response to a transient. The cause of the parameter change or event may be known or unknown.

Basis:

In this EAL, all RCS water level indication would be unavailable for greater than 30 minutes, and the RCS inventory loss must be detected by indirect leakage indications. Sump level increases must be evaluated against other potential sources of leakage. If the make-up rate to the RCS unexplainably rises above the pre-established rate, a loss of RCS inventory may be occurring even if the source of the leakage cannot be immediately identified. Sumps and tanks where RCS leakage may accumulate are listed in listed in Table C-1 (ref. 1, 2).

In the Refueling Mode, as water level in the reactor vessel lowers, the dose rate above the core will increase. The dose rate due to core uncover will result in indications on the Containment Ventilation Isolation (CVI) area radiation monitors. A calculation (ref. 4) shows that if these radiation monitors reach and exceed 2.6E+04 mR/hr when the reactor vessel head is removed, with RCS water level indication unavailable for greater than 30 minutes, then a loss of inventory with potential to uncover the core is likely to have occurred.

Post-TMI accident studies indicated that the installed PWR nuclear instrumentation will operate erratically when the core is uncovered and that this should be used as a tool for making such determinations.

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 78 of 220 Three conditions are associated with a challenge to containment integrity:

  • CONTAINMENT CLOSURE is not established.
  • In the early stages of a core uncovery event, it is unlikely that hydrogen buildup due to a core uncovery could result in an explosive mixture of dissolved gases in the containment. However, containment monitoring and/or sampling should be performed to verify this assumption and a General Emergency declared if it is determined that an explosive mixture exists. An explosive mixture can be formed when hydrogen gas concentration in the containment atmosphere is greater than 4% by volume in the presence of oxygen.
  • Any unplanned increase in containment pressure in the Cold Shutdown or Refueling mode indicates a potential loss of containment closure capability. Unplanned containment pressure increases indicates containment closure cannot be assured and the containment cannot be relied upon as a barrier to fission product release.

This IC addresses the inability to restore and maintain reactor vessel level above the top of active fuel with containment challenged. This condition represents actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity.

Releases can be reasonably expected to exceed EPA PAG exposure levels offsite for more than the immediate site area.

Following an extended loss of core decay heat removal and inventory makeup, decay heat will cause reactor coolant boiling and a further reduction in reactor vessel level. If RCS level cannot be restored, fuel damage is probable.

With CONTAINMENT CLOSURE not established, there is a high potential for a direct and unmonitored release of radioactivity to the environment. If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, then declaration of a General Emergency is not required.

The existence of an explosive mixture means, at a minimum, that the containment atmospheric hydrogen concentration is sufficient to support a hydrogen burn (i.e., at the lower deflagration limit). A hydrogen burn will raise containment pressure and could result in collateral equipment damage leading to a loss of containment integrity. It therefore represents a challenge to Containment integrity.

In the early stages of a core uncovery event, it is unlikely that hydrogen buildup due to a core uncovery could result in an explosive gas mixture in containment. If all installed hydrogen gas monitors are out-of-service during an event leading to fuel cladding damage, it may not be possible to obtain a containment hydrogen gas concentration reading as ambient conditions within the containment will preclude personnel access. During periods when installed containment hydrogen gas monitors are out-of-service, operators may use the other listed indications to assess whether or not containment is challenged.

ATTACHMENT 1 EAL Bases EP-EAL Rev. XXX DRAFT Page 79 of 220 The 30-minute criterion is tied to a readily recognizable event start time (i.e., the total loss of ability to monitor level), and allows sufficient time to monitor, assess and correlate reactor and plant conditions to determine if core uncovery has actually occurred (i.e., to account for various accident progression and instrumentation uncertainties). It also allows sufficient time for performance of actions to terminate leakage, recover inventory control/makeup equipment and/or restore level monitoring.

The inability to monitor RCS level may be caused by instrumentation and/or power failures, or water level dropping below the range of available instrumentation. If water level cannot be monitored, operators may determine that an inventory loss is occurring by observing changes in sump and/or tank levels. Sump and/or tank level changes must be evaluated against other potential sources of water flow to ensure they are indicative of leakage from the RCS.

EAL values should be determined with a margin sufficient to ensure that an accurate monitor reading is available. For example, an EAL monitor reading might be set at 90% to 95% of the highest accurate monitor reading.

A single calculated radiation monitor reading does not represent core uncovery for all event scenarios due to multiple variables that can affect the source term (i.e., number of fuel assemblies in the core, fuel burn up in each assembly, and time after shutdown). Therefore, consideration has been given so that the threshold value of > 2.6E+04 mR/hr on the CVI radiation monitors will be low enough to be a valid indication of fuel uncovery, but high enough so that inadvertent classifications are not caused by maintenance events or other conditions that may increase radiation levels without a coincident loss of reactor vessel water level (ref. 4).

HNP utilizes CVI area radiation monitors RM-1CR-3561A-SA, 1RM-1CR-3561B-SB, RM-1CR-3561C-SA, and RM-1CR-3561D-SB for evaluating conditions in containment. The sensitivity and location of these monitors allows them to detect significant changes in the loss of water shielding from the reactor cavity, which can be used to detect core uncovery.

This EAL addresses concerns raised by Generic Letter 88-17, Loss of Decay Heat Removal; SECY 91-283, Evaluation of Shutdown and Low Power Risk Issues; NUREG-1449, Shutdown and Low-Power Operation at Commercial Nuclear Power Plants in the United States; and NUMARC 91-06, Guidelines for Industry Actions to Assess Shutdown Management.

HNP Basis Reference(s):

1. GP-001, Reactor Coolant System Fill and Vent Mode 5
2. GP-008, Draining the Reactor Coolant System
3. GP-009, Refueling Cavity Fill, Refueling and Drain of the Refueling Cavity Modes 5-6-5
4. CSD-EP-HNP-0101-06, Radiation Monitor Readings for Core Uncovery during Refueling
5. NEI 99-01 CG1

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 177 of 220 Table F-1 Fission Product Barrier Threshold Matrix Fuel Clad (FC) Barrier Reactor Coolant System (RCS) Barrier Containment (CNMT) Barrier Category Loss Potential Loss Loss Potential Loss Loss Potential Loss A

RCS or SG Tube Leakage None None

1. An automatic or manual ECCS (SI) actuation required by EITHER:
  • UNISOLABLE RCS leakage
  • SG tube RUPTURE
1. CSFST Integrity-RED Path entry conditions met
1. A leaking or RUPTURED SG is FAULTED outside of containment None B

Inadequate Heat Removal

1. CSFST Core Cooling-RED Path entry conditions met
1. CSFST Core Cooling-ORANGE PATH entry conditions met
2. CSFST Heat Sink-RED Path entry conditions met AND Heat sink is required None
1. CSFST Heat Sink-RED Path entry conditions met AND Heat sink is required None
1.

CSFST Core Cooling-RED Path entry conditions met AND Restoration procedures not effective within 15 min. (Note 1)

C CNMT Radiation

/ RCS Activity

1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column FC Barrier Loss
2. Dose equivalent I-131 coolant activity > 300 µCi/gm None
1. (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB) > Table F-2 Column RCS Barrier Loss None None
1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column CNMT Potential Loss D

CNMT Integrity or Bypass None None None None

1. Containment isolation is required AND EITHER:
  • Containment integrity has been lost based on Emergency Coordinator judgment
  • UNISOLABLE pathway from Containment to the environment exists
2. Indications of RCS leakage outside of containment
1.

CSFST Containment-RED Path entry conditions met

2. Containment hydrogen concentration

> 4%

3. Containment pressure > 10 psig with < one full train of depressurization equipment operating (one CNMT spray pump and two CNMT fan coolers) per design for 15 min.

(Note 1)

E EC Judgment

1. Any condition in the opinion of the Emergency Coordinator that indicates loss of the fuel clad barrier
1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the fuel clad barrier

1.

Any condition in the opinion of the Emergency Coordinator that indicates loss of the RCS barrier

1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the RCS barrier

1.

Any condition in the opinion of the Emergency Coordinator that indicates loss of the containment barrier

1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the containment barrier Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 183 of 220 Barrier:

Fuel Clad Category:

C. CNMT Radiation / RCS Activity Degradation Threat: Loss Threshold:

1. RM-1CR-3589SA or RM-1CR-3590SB > Table F-2, Column FC Barrier Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

Containment radiation monitor readings greater than Table F-2, FC Barrier Loss indicate the release of reactor coolant, with elevated activity indicative of fuel damage, into the Containment. The radiation monitor reading is derived assuming the instantaneous release and dispersal of the reactor coolant noble gas and iodine inventory associated with a concentration of 300 µCi/cc dose equivalent I-131 into the Containment atmosphere (ref. 1).

Reactor coolant concentrations of this magnitude are several times larger than the maximum concentrations (including iodine spiking) allowed within technical specifications and are therefore indicative of fuel damage.

RM-1CR-3589SA and RM-1CR-3590SB are the Containment High Range Monitors that provide indication of radiation levels in Containment during and after postulated accidents (ref. 2).

Since this condition indicates that a significant amount of fuel clad damage has occurred, it represents a loss of the Fuel Clad Barrier.

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 184 of 220 The radiation monitor reading in this threshold is higher than that specified for RCS Barrier Loss threshold C.1 since it indicates a loss of both the Fuel Clad Barrier and the RCS Barrier.

Note that a combination of the two monitor readings appropriately escalates the ECL to a Site Area Emergency.

HNP Basis Reference(s):

1. EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. NEI 99-01 CNMT Radiation / RCS Activity Fuel Clad Loss 3.A

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 195 of 220 Barrier:

Reactor Coolant System Category:

C. CNMT Radiation/ RCS Activity Degradation Threat: Loss Threshold:

1. A Containment Ventilation Isolation Radiation Monitor (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB) > Table F-2, Column RCS Barrier Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

A Containment Ventilation Isolation radiation monitor reading greater than Table F-2, RCS Barrier Loss (ref. 1) indicates the release of reactor coolant into containment. The readings assume the instantaneous release and dispersal of the reactor coolant noble gas and iodine inventory associated with normal operating concentrations (i.e., within Technical Specifications) into the Containment atmosphere. Because of the very high fuel clad integrity, only small amounts of noble gases would be dissolved in the primary coolant.

The radiation monitor reading corresponds to an instantaneous release of all reactor coolant mass into the containment, assuming that reactor coolant activity equals Technical Specification allowable limits. This value is lower than that specified for Fuel Clad Barrier Loss threshold C.1 since it indicates a loss of the RCS Barrier only.

There is no Potential Loss threshold associated with RCS Activity / Containment Radiation.

HNP Basis Reference(s):

1. EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. NEI 99-01 CNMT Radiation / RCS Activity RCS Loss 3.A

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 208 of 220 Barrier:

Containment Category:

C. CNMT Radiation/RCS Activity Degradation Threat: Potential Loss Threshold:

1. RM-1CR-3589SA or RM-1CR-3590SB > Table F-2, Column CNMT Potential Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

Containment radiation monitor readings on RM-1CR-3589SA or RM-1CR-3590SB >

Table F-2 column CNMT Potential Loss indicate significant fuel damage well in excess of that required for loss of the RCS barrier and the Fuel Clad barrier (ref. 1).

The readings are higher than that specified for Fuel Clad Loss C.1 and RCS Loss C.1.

Containment radiation readings at or above the Containment barrier Potential Loss threshold, therefore, signify a loss of two fission product barriers and Potential Loss of the third, indicating the need to upgrade the emergency classification to a General Emergency.

RM-1CR-3589SA and RM-1CR-3590SB are the Containment High Range Monitors that provide indication of radiation levels in Containment during and after postulated accidents (ref. 2).

The radiation monitor reading corresponds to an instantaneous release of all reactor coolant mass into the containment, assuming that 20% of the fuel cladding has failed. This level of fuel clad failure is well above that used to determine the analogous Fuel Clad Barrier Loss and RCS Barrier Loss thresholds.

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. XXX DRAFT Page 209 of 220 NUREG-1228, Source Estimations During Incident Response to Severe Nuclear Power Plant Accidents, indicates the fuel clad failure must be greater than approximately 20% in order for there to be a major release of radioactivity requiring offsite protective actions. For this condition to exist, there must already have been a loss of the RCS Barrier and the Fuel Clad Barrier. It is therefore prudent to treat this condition as a potential loss of containment which would then escalate the ECL to a General Emergency.

HNP Basis Reference(s):

1. EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. NEI 99-01 CNMT Radiation / RCS Activity Containment Potential Loss 3.A

U.S. Nuclear Regulatory Commission Serial RA-18-0248, Enclosure 3 SERIAL RA-18-0248 ENCLOSURE 3 PROPOSED HARRIS NUCLEAR PLANT EMERGENCY ACTION LEVEL TECHNICAL BASES DOCUMENT CHANGES, EP-EAL (MARKUP)

SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 DOCKET NO. 50-400 RENEWED LICENSE NUMBER NPF-63

ATTACHMENT 1 EAL Bases EP-EAL Rev. 17 Page 70 of 219 Category:

C - Cold Shutdown / Refueling System Malfunction Subcategory:

1 - RCS Level Initiating Condition: Loss of RCS inventory affecting core decay heat removal capability EAL:

CS1.3 Site Area Emergency RCS water level cannot be monitored for 30 min. Note 1

AND Core uncovery is indicated by any of the following:

x UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery x

Containment radiation > 10,000 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB) x Erratic source range monitor indication Note 1:

The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Table C-1 Sumps / Tanks x

Containment sumps x

PRT x

RCDT x

CCW surge tank x

RAB sumps x

RWST x

RMWST x

Recycle Holdup Tank Mode Applicability:

5 - Cold Shutdown, 6 - Refueling Definition(s):

UNISOLABLE - An open or breached system line that cannot be isolated, remotely or locally.

UNPLANNED - A parameter change or an event that is not 1) the result of an intended evolution or 2) an expected plant response to a transient. The cause of the parameter change or event may be known or unknown.

Basis:

In this EAL, all RCS water level indication would be unavailable for greater than 30 minutes, and the RCS inventory loss must be detected by indirect leakage indications. Sump level increases must be evaluated against other potential sources of leakage. If the make-up rate to the RCS unexplainably rises above the pre-established rate, a loss of RCS inventory may be occurring even if the source of the leakage cannot be immediately identified. Sumps and tanks where RCS leakage may accumulate are listed in listed in Table C-1(ref. 1, 2).

Replace with:

"A Containment Ventilation Isolation Radiation Monitor >

2.6E+04 mR/hr (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB)"

ATTACHMENT 1 EAL Bases EP-EAL Rev. 17 Page 71 of 219 In the Refueling Mode, as water level in the reactor vessel lowers, the dose rate above the core will increase. The dose rate due to this core shine should result in indications on installed area radiation monitors (RM-1CR-3589-SA or RM-1CR-3590-SB). If these radiation monitors reach and exceed 10,000 R/hr, a loss of inventory with potential to uncover the core is likely to have occurred (ref. 4).

Post-TMI accident studies indicated that the installed PWR nuclear instrumentation will operate erratically when the core is uncovered and that this should be used as a tool for making such determinations.

This IC addresses a significant and prolonged loss of RCS inventory control and makeup capability leading to IMMINENT fuel damage. The lost inventory may be due to a RCS component failure, a loss of configuration control or prolonged boiling of reactor coolant.

These conditions entail major failures of plant functions needed for protection of the public and thus warrant a Site Area Emergency declaration.

Following an extended loss of core decay heat removal and inventory makeup, decay heat will cause reactor coolant boiling and a further reduction in reactor vessel level. If RCS level cannot be restored, fuel damage is probable.

The 30-minute criterion is tied to a readily recognizable event start time (i.e., the total loss of ability to monitor level), and allows sufficient time to monitor, assess and correlate reactor and plant conditions to determine if core uncovery has actually occurred (i.e., to account for various accident progression and instrumentation uncertainties). It also allows sufficient time for performance of actions to terminate leakage, recover inventory control/makeup equipment and/or restore level monitoring.

The inability to monitor RCS level may be caused by instrumentation and/or power failures, or water level dropping below the range of available instrumentation. If water level cannot be monitored, operators may determine that an inventory loss is occurring by observing changes in sump and/or tank levels. Sump and/or tank level changes must be evaluated against other potential sources of water flow to ensure they are indicative of leakage from the RCS.

This EAL addresses concerns raised by Generic Letter 88-17, Loss of Decay Heat Removal; SECY 91-283, Evaluation of Shutdown and Low Power Risk Issues; NUREG-1449, Shutdown and Low-Power Operation at Commercial Nuclear Power Plants in the United States; and NUMARC 91-06, Guidelines for Industry Actions to Assess Shutdown Management.

Escalation of the emergency classification level would be via IC CG1 or RG1 HNP Basis Reference(s):

1. GP-001, Reactor Coolant System Fill and Vent Mode 5
2. GP-008, Draining the Reactor Coolant System
3. GP-009, Refueling Cavity Fill, Refueling and Drain of the Refueling Cavity Modes 5-6-5
4. AOP-031-BD, Loss of Refueling Cavity Integrity-Basis Document
5. NEI 99-01 CS1 Add INSERT B Replace with INSERT A Replace with: "CSD-EP-HNP-0101-06, Radiation Monitor Readings for Core Uncovery during Refueling"

INSERT A:

INSERT B:

EAL values should be determined with a margin sufficient to ensure that an accurate monitor reading is available. For example, an EAL monitor reading might be set at 90% to 95% of the highest accurate monitor reading.

A single calculated radiation monitor reading does not represent core uncovery for all event scenarios due to multiple variables that can affect the source term (i.e., number of fuel assemblies in the core, fuel burn up in each assembly, and time after shutdown). Therefore, consideration has been given so that the threshold value of >

2.6E+04 mR/hr on the CVI radiation monitors will be low enough to be a valid indication of fuel uncovery, but high enough so that inadvertent classifications are not caused by maintenance events or other conditions that may increase radiation levels without a coincident loss of reactor vessel water level (ref. 4).

HNP utilizes CVI area radiation monitors RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, and RM-1CR-3561D-SB for evaluating conditions in containment.

The sensitivity and location of these monitors allows them to detect significant changes in the loss of water shielding from the reactor cavity, which can be used to detect core uncovery.

The dose rate due to this loss of water shielding from the reactor cavity will result in indications on the Containment Ventilation Isolation (CVI) area radiation monitors. A calculation (ref. 4) shows that if these radiation monitors reach and exceed 2.6E+04 mR/hr when the reactor vessel head is removed, with RCS water level indication unavailable for greater than 30 minutes, then a loss of inventory with potential to uncover the core is likely to have occurred.

ATTACHMENT 1 EAL Bases EP-EAL Rev. 17 Page 75 of 219 Category:

C - Cold Shutdown / Refueling System Malfunction Subcategory:

1 - RCS Level Initiating Condition: Loss of RCS inventory affecting fuel clad integrity with containment challenged EAL:

CG1.2 General Emergency RCS level cannot be monitored for 30 min. (Note 1)

AND Core uncovery is indicated by any of the following:

x UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery x

Containment radiation > 10,000 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB) x Erratic source range monitor indication AND Any Containment Challenge indication, Table C-2 Note 1:

The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 6:

If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Table C-1 Sumps / Tanks x

Containment sumps x

PRT x

RCDT x

CCW surge tank x

RAB sumps x

RWST x

RMWST x

Recycle Holdup Tank Table C-2 Containment Challenge Indications x

CONTAINMENT CLOSURE not established (Note 6) x Containment hydrogen concentration 4

x UNPLANNED rise in Containment pressure Replace with:

"A Containment Ventilation Isolation Radiation Monitor >

2.6E+04 mR/hr (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB)"

ATTACHMENT 1 EAL Bases EP-EAL Rev. 17 Page 76 of 219 Mode Applicability:

5 - Cold Shutdown, 6 - Refueling Definition(s):

CONTAINMENT CLOSURE - The procedurally defined actions taken to secure containment and its associated structures, systems, and components as a functional barrier to fission product release under shutdown conditions. As applied to HNP, Containment Closure is established when containment penetration closure is established in accordance with Technical Specifications 3/4.9.4.

UNISOLABLE - An open or breached system line that cannot be isolated, remotely or locally.

UNPLANNED - A parameter change or an event that is not 1) the result of an intended evolution or 2) an expected plant response to a transient. The cause of the parameter change or event may be known or unknown.

Basis:

In this EAL, all RCS water level indication would be unavailable for greater than 30 minutes, and the RCS inventory loss must be detected by indirect leakage indications. Sump level increases must be evaluated against other potential sources of leakage. If the make-up rate to the RCS unexplainably rises above the pre-established rate, a loss of RCS inventory may be occurring even if the source of the leakage cannot be immediately identified. Sumps and tanks where RCS leakage may accumulate are listed in listed in Table C-1 (ref. 1, 2).

In the Refueling Mode, as water level in the reactor vessel lowers, the dose rate above the core will increase. The dose rate due to this core shine should result in indications on installed area radiation monitors (RM-1CR-3589-SA or RM-1CR-3590-SB). If these radiation monitors reach and exceed 10,000 R/hr, a loss of inventory with potential to uncover the core is likely to have occurred (ref. 4).

Post-TMI accident studies indicated that the installed PWR nuclear instrumentation will operate erratically when the core is uncovered and that this should be used as a tool for making such determinations.

Three conditions are associated with a challenge to containment integrity:

x CONTAINMENT CLOSURE is not established.

x In the early stages of a core uncovery event, it is unlikely that hydrogen buildup due to a core uncovery could result in an explosive mixture of dissolved gases in the containment. However, containment monitoring and/or sampling should be performed to verify this assumption and a General Emergency declared if it is determined that an explosive mixture exists. An explosive mixture can be formed when hydrogen gas concentration in the containment atmosphere is greater than 4% by volume in the presence of oxygen.

x Any unplanned increase in containment pressure in the Cold Shutdown or Refueling mode indicates a potential loss of containment closure capability. Unplanned containment pressure increases indicates containment closure cannot be assured and the containment cannot be relied upon as a barrier to fission product release.

Add INSERT C

INSERT C:

The dose rate due to core uncover will result in indications on the Containment Ventilation Isolation (CVI) area radiation monitors. A calculation (ref. 4) shows that if these radiation monitors reach and exceed 2.6E+04 mR/hr when the reactor vessel head is removed, with RCS water level indication unavailable for greater than 30 minutes, then a loss of inventory with potential to uncover the core is likely to have occurred.

ATTACHMENT 1 EAL Bases EP-EAL Rev. 17 Page 77 of 219 This IC addresses the inability to restore and maintain reactor vessel level above the top of active fuel with containment challenged. This condition represents actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity.

Releases can be reasonably expected to exceed EPA PAG exposure levels offsite for more than the immediate site area.

Following an extended loss of core decay heat removal and inventory makeup, decay heat will cause reactor coolant boiling and a further reduction in reactor vessel level. If RCS level cannot be restored, fuel damage is probable.

With CONTAINMENT CLOSURE not established, there is a high potential for a direct and unmonitored release of radioactivity to the environment. If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, then declaration of a General Emergency is not required.

The existence of an explosive mixture means, at a minimum, that the containment atmospheric hydrogen concentration is sufficient to support a hydrogen burn (i.e., at the lower deflagration limit). A hydrogen burn will raise containment pressure and could result in collateral equipment damage leading to a loss of containment integrity. It therefore represents a challenge to Containment integrity.

In the early stages of a core uncovery event, it is unlikely that hydrogen buildup due to a core uncovery could result in an explosive gas mixture in containment. If all installed hydrogen gas monitors are out-of-service during an event leading to fuel cladding damage, it may not be possible to obtain a containment hydrogen gas concentration reading as ambient conditions within the containment will preclude personnel access. During periods when installed containment hydrogen gas monitors are out-of-service, operators may use the other listed indications to assess whether or not containment is challenged.

The 30-minute criterion is tied to a readily recognizable event start time (i.e., the total loss of ability to monitor level), and allows sufficient time to monitor, assess and correlate reactor and plant conditions to determine if core uncovery has actually occurred (i.e., to account for various accident progression and instrumentation uncertainties). It also allows sufficient time for performance of actions to terminate leakage, recover inventory control/makeup equipment and/or restore level monitoring.

The inability to monitor RCS level may be caused by instrumentation and/or power failures, or water level dropping below the range of available instrumentation. If water level cannot be monitored, operators may determine that an inventory loss is occurring by observing changes in sump and/or tank levels. Sump and/or tank level changes must be evaluated against other potential sources of water flow to ensure they are indicative of leakage from the RCS.

This EAL addresses concerns raised by Generic Letter 88-17, Loss of Decay Heat Removal; SECY 91-283, Evaluation of Shutdown and Low Power Risk Issues; NUREG-1449, Shutdown and Low-Power Operation at Commercial Nuclear Power Plants in the United States; and NUMARC 91-06, Guidelines for Industry Actions to Assess Shutdown Management.

HNP Basis Reference(s):

1. GP-001, Reactor Coolant System Fill and Vent Mode 5
2. GP-008, Draining the Reactor Coolant System
3. GP-009, Refueling Cavity Fill, Refueling and Drain of the Refueling Cavity Modes 5-6-5
4. AOP-031-BD, Loss of Refueling Cavity Integrity-Basis Document
5. NEI 99-01 CG1 Add INSERT D Replace with: "CSD-EP-HNP-0101-06, Radiation Monitor Readings for Core Uncovery during Refueling"

INSERT D:

EAL values should be determined with a margin sufficient to ensure that an accurate monitor reading is available. For example, an EAL monitor reading might be set at 90% to 95% of the highest accurate monitor reading.

A single calculated radiation monitor reading does not represent core uncovery for all event scenarios due to multiple variables that can affect the source term (i.e., number of fuel assemblies in the core, fuel burn up in each assembly, and time after shutdown). Therefore, consideration has been given so that the threshold value of >

2.6E+04 mR/hr on the CVI radiation monitors will be low enough to be a valid indication of fuel uncovery, but high enough so that inadvertent classifications are not caused by maintenance events or other conditions that may increase radiation levels without a coincident loss of reactor vessel water level (ref. 4).

HNP utilizes CVI area radiation monitors RM-1CR-3561A-SA, 1RM-1CR-3561B-SB, RM-1CR-3561C-SA, and RM-1CR-3561D-SB for evaluating conditions in containment.

The sensitivity and location of these monitors allows them to detect significant changes in the loss of water shielding from the reactor cavity, which can be used to detect core uncovery.

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. 17 Page 175 of 219 Table F-1 Fission Product Barrier Threshold Matrix Fuel Clad (FC) Barrier Reactor Coolant System (RCS) Barrier Containment (CNMT) Barrier Category Loss Potential Loss Loss Potential Loss Loss Potential Loss A

RCS or SG Tube Leakage None None 1.

An automatic or manual ECCS (SI) actuation required by EITHER:

x UNISOLABLE RCS leakage x SG tube RUPTURE 1.

Operation of a standby charging pump is required by EITHER:

x UNISOLABLE RCS leakage x

SG tube leakage 2.

CSFST Integrity-RED Path entry conditions met

1. A leaking or RUPTURED SG is FAULTED outside of containment None B

Inadequate Heat Removal 1.

CSFST Core Cooling-RED Path entry conditions met 1.

CSFST Core Cooling-ORANGE PATH entry conditions met 2.

CSFST Heat Sink-RED Path entry conditions met AND Heat sink is required None 1.

CSFST Heat Sink-RED Path entry conditions met AND Heat sink is required None 1.

CSFST Core Cooling-RED Path entry conditions met AND Restoration procedures not effective within 15 min. (Note 1)

C CNMT Radiation

/ RCS Activity

1. Containment radiation

>150 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB) 2.

Dose equivalent I-131 coolant activity > 300 Ci/gm None 1.

Containment Leak Detection Monitor Noble Gas (REM-1LT-3502A-SA)

> 8.3E-3 Ci/ml None None 1.

Containment radiation

>600 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

D CNMT Integrity or Bypass None None None None 1.

Containment isolation is required AND EITHER:

x Containment integrity has been lost based on Emergency Coordinator judgment x UNISOLABLE pathway from Containment to the environment exists 2.

Indications of RCS leakage outside of containment 1.

CSFST Containment-RED Path entry conditions met

2.

Containment hydrogen concentration

> 4%

3.

Containment pressure > 10 psig with < one full train of depressurization equipment operating (one CNMT spray pump and two CNMT fan coolers) per design for 15 min.

(Note 1)

E EC Judgment 1.

Any condition in the opinion of the Emergency Coordinator that indicates loss of the fuel clad barrier 1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the fuel clad barrier 1.

Any condition in the opinion of the Emergency Coordinator that indicates loss of the RCS barrier 1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the RCS barrier 1.

Any condition in the opinion of the Emergency Coordinator that indicates loss of the containment barrier 1.

Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the containment barrier Revise to "1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column FC Barrier Loss" Revise to

1. " (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB) > Table F-2 Column RCS Barrier Loss" Revise to "1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column CNMT Potential Loss" Add INSERT H

INSERT H:

Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. 17 Page 181 of 219 Barrier:

Fuel Clad Category:

C. CNMT Radiation / RCS Activity Degradation Threat: Loss Threshold:

1. Containment radiation >150 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

Definition(s):

None Basis:

Containment radiation monitor readings greater than 150.3 R/hr, rounded to 150 R/hr for readability, indicate the release of reactor coolant, with elevated activity indicative of fuel damage, into the Containment. The reading is derived assuming the instantaneous release and dispersal of the reactor coolant noble gas and iodine inventory associated with a concentration of 300 Ci/cc dose equivalent I-131 into the Containment atmosphere.

Reactor coolant concentrations of this magnitude are several times larger than the maximum concentrations (including iodine spiking) allowed within technical specifications and are therefore indicative of fuel damage (approximately 5% clad failure depending on core inventory and RCS volume). (ref. 1)

RM-1CR-3589-SA and RM-1CR-3590-SB are the Containment High Range Monitors that provide indication of radiation levels in Containment during and after postulated accidents.

The Alert alarms are set at 6.5 R/hr and the High alarms are set at 17.5 R/hr. (ref. 2, 3).

The radiation monitor reading corresponds to an instantaneous release of all reactor coolant mass into the containment, assuming that reactor coolant activity equals 300 Ci/gm dose equivalent I-131. Reactor coolant activity above this level is greater than that expected for iodine spikes and corresponds to an approximate range of 2% to 5% fuel clad damage. Since this condition indicates that a significant amount of fuel clad damage has occurred, it represents a loss of the Fuel Clad Barrier.

The radiation monitor reading in this threshold is higher than that specified for RCS Barrier Loss threshold C.1 since it indicates a loss of both the Fuel Clad Barrier and the RCS Barrier.

Note that a combination of the two monitor readings appropriately escalates the ECL to a Site Area Emergency.

HNP Basis Reference(s):

1. Calculation 3-B-12-022, DHRAM-Response to a Fuel and RCS Breach
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. HP-500, Radiation Monitoring System Data Base Manual
4. NEI 99-01 CNMT Radiation / RCS Activity Fuel Clad Loss 3.A Replace with 'INSERT E' from the following page:

Revise:

"EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values" RM-1CR-3589SA and RM-1CR-3590SB 3.

INSERT E:

1. RM-1CR-3589SA or RM-1CR-3590SB > Table F-2, Column FC Barrier Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

Containment radiation monitor readings greater than Table F-2, FC Barrier Loss indicate the release of reactor coolant, with elevated activity indicative of fuel damage, into the Containment. The radiation monitor reading is derived assuming the instantaneous release and dispersal of the reactor coolant noble gas and iodine inventory associated with a concentration of 300 Ci/cc dose equivalent I-131 into the Containment atmosphere (ref. 1).

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. 17 Page 193 of 219 Barrier:

Reactor Coolant System Category:

C. CNMT Radiation/ RCS Activity Degradation Threat: Loss Threshold:

1. Containment Leak Detection Monitor Noble Gas (REM-1LT-3502A-SA)

> 8.3E-3 Ci/ml Definition(s):

None Basis:

Containment radiation monitor readings on REM-1LT-3502A-SA noble gas channel greater than 8.3E-3 Ci/ml (ref. 1) indicate the release of reactor coolant to the Containment. The readings assume the instantaneous release and dispersal of the reactor coolant noble gas and iodine inventory associated with normal operating concentrations (i.e., within Technical Specifications) into the Containment atmosphere. Because of the very high fuel clad integrity, only small amounts of noble gases would be dissolved in the primary coolant.

The Containment High Range Monitors (RM-1CR-3589-SA or RM-1CR-3590-SB) are bugged to read at least 1 R/hr and are not capable of detecting this radiation level (ref. 2, 3).

The radiation monitor reading corresponds to an instantaneous release of all reactor coolant mass into the containment, assuming that reactor coolant activity equals Technical Specification allowable limits. This value is lower than that specified for Fuel Clad Barrier Loss threshold C.1 since it indicates a loss of the RCS Barrier only.

There is no Potential Loss threshold associated with RCS Activity / Containment Radiation.

HNP Basis Reference(s):

1. Calculation HNP-M/MECH-1074, Alternate Source Term Effect on REM-3502A Response to RCS Breach with Non-Failed Fuel
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. HP-500, Radiation Monitoring System Data Base Manual
4. NEI 99-01 CNMT Radiation / RCS Activity RCS Loss 3.A Revise:

"EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values" Replace with

'INSERT F' from the following page:

3.

INSERT F:

1. A Containment Ventilation Isolation Radiation Monitor (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB) > Table F-2, Column RCS Barrier Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

A Containment Ventilation Isolation radiation monitor reading greater than Table F-2, RCS Barrier Loss (ref. 1) indicates the release of reactor coolant into containment.

ATTACHMENT 2 Fission Product Barrier Loss/Potential Loss Matrix and Bases EP-EAL Rev. 17 Page 206 of 219 Barrier:

Containment Category:

C. CNMT Radiation/RCS Activity Degradation Threat: Potential Loss Threshold:

1.

Containment radiation > 600 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

Definition(s):

None Basis:

Containment radiation monitor readings greater than 601.2 R/hr, rounded to 600 R/hr for readability, (ref. 1) indicate significant fuel damage well in excess of that required for loss of the RCS barrier and the Fuel Clad barrier.

The readings are higher than that specified for Fuel Clad Loss C.1 and RCS Loss C.1.

Containment radiation readings at or above the Containment barrier Potential Loss threshold, therefore, signify a loss of two fission product barriers and Potential Loss of the third, indicating the need to upgrade the emergency classification to a General Emergency.

RM-1CR-3589SA and RM-1CR-3590SB are the Containment High Range Monitors that provide indication of radiation levels in Containment during and after postulated accidents.

The Alert alarms are set at 6.5 R/hr and the High alarms are set at 17.5 R/hr. (ref. 2, 3).

The radiation monitor reading corresponds to an instantaneous release of all reactor coolant mass into the containment, assuming that 20% of the fuel cladding has failed. This level of fuel clad failure is well above that used to determine the analogous Fuel Clad Barrier Loss and RCS Barrier Loss thresholds.

NUREG-1228, Source Estimations During Incident Response to Severe Nuclear Power Plant Accidents, indicates the fuel clad failure must be greater than approximately 20% in order for there to be a major release of radioactivity requiring offsite protective actions. For this condition to exist, there must already have been a loss of the RCS Barrier and the Fuel Clad Barrier. It is therefore prudent to treat this condition as a potential loss of containment which would then escalate the ECL to a General Emergency.

HNP Basis Reference(s):

1. Calculation 3-B-12-022 DHRAM, Response to a Fuel and RCS Breach
2. DBD-304, Radiation Monitoring System and Gross Failed Fuel Monitor
3. HP-500, Radiation Monitoring System Data Base Manual
4. NEI 99-01 CNMT Radiation / RCS Activity Containment Potential Loss 3.A Replace with 'INSERT G' from the following page:

Revise:

"EP-EALCALC-HNP-1701, Containment Radiation EAL Threshold Values" RM-1CR-3589SA and RM-1CR-3590SB 3.

INSERT G:

1. RM-1CR-3589SA or RM-1CR-3590SB > Table F-2, Column CNMT Potential Loss Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr Definition(s):

None Basis:

Containment radiation monitor readings on RM-1CR-3589SA or RM-1CR-3590SB >

Table F-2 column CNMT Potential Loss indicate significant fuel damage well in excess of that required for loss of the RCS barrier and the Fuel Clad barrier (ref. 1).

U.S. Nuclear Regulatory Commission Serial RA-18-0248, Enclosure 4 SERIAL RA-18-0248 ENCLOSURE 4 PROPOSED HARRIS NUCLEAR PLANT EMERGENCY ACTION LEVEL WALLCHART CHANGES (MARKUP)

SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 DOCKET NO. 50-400 RENEWED LICENSE NUMBER NPF-63

CA1.1 Loss of RCS inventory as indicated by LI-403 or RCS standpipe level < - 82 in.

CU1.1 UNPLANNED loss of reactor coolant results in RCS water level less than a required lower limit for ³ 15 min. (Note 1)

RCS water level cannot be monitored AND EITHER UNPLANNED increase in any Table C-1 sump or tank due to a loss of RCS inventory Visual observation of UNISOLABLE RCS leakage CU1.2 RCS water level cannot be monitored for ³ 30 min. (Note 1)

AND Core uncovery is indicated by any of the following:

UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery Containment radiation > 10,000 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

Erratic source range monitor indication RCS water level cannot be monitored for ³ 30 min. (Note 1)

AND Core uncovery is indicated by any of the following:

UNPLANNED increase in any Table C-1 sump or tank of sufficient magnitude to indicate core uncovery Containment radiation > 10,000 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

Erratic source range monitor indication AND Any Containment Challenge indication, Table C-2 RCS water level cannot be monitored for ³ 15 min. (Note 1)

AND EITHER UNPLANNED increase in any Table C-1 sump or tank due to a loss of RCS inventory Visual observation of UNISOLABLE RCS leakage CA1.2 None Cold SD/

Refuel System Malfunct.

Loss of Emergency AC Power Loss of all but one AC power source to emergency buses for 15 minutes or longer CU2.1 AC power capability, Table C-6, to emergency 6.9 KV buses 1A-SA and 1B-SB reduced to a single power source for

³ 15 min. (Note 1)

AND Any additional single power source failure will result in loss of all AC power to SAFETY SYSTEMS

< 105 VDC bus voltage indications on Technical Specification required 125 VDC buses (DP-1A-SA, DP-1B-SB) for ³ 15 min.

(Note 1)

CU4.1 CG1.2 Loss of RCS inventory Loss of RCS inventory affecting core decay heat removal capability Loss of RCS inventory affecting fuel clad integrity with containment challenged RCS Level Loss of Comm.

Loss of all onsite or offsite communications capabilities CU5.1 UNPLANNED loss of RCS inventory for 15 minutes or longer Loss of Vital DC power for 15 minutes or longer CA2.1 Loss of all offsite and all onsite AC power capability to 6.9 KV emergency buses 1A-SA and 1B-SB for ³ 15 min. (Note 1)

Loss of all offsite and all onsite AC power to emergency buses for 15 minutes or longer CS1.3 RCS Temp.

UNPLANNED increase in RCS temperature to > 200°F CU3.1 UNPLANNED increase in RCS temperature Loss of all RCS temperature and RCS level indication for ³ 15 min. (Note 1)

CU3.2 CA3.1 UNPLANNED increase in RCS temperature to > 200°F for > Table C-3 duration (Note 1)

OR UNPLANNED RCS pressure increase > 10 psig (this does not apply during water-solid plant conditions)

Inability to maintain plant in cold shutdown Hazardous Event Affecting Safety Systems C

1 3

5 6

The occurrence of any Table C-5 hazardous event AND EITHER:

Event damage has caused indications of degraded performance in at least one train of a SAFETY SYSTEM needed for the current operating mode The event has caused VISIBLE DAMAGE to a SAFETY SYSTEM component or structure needed for the current operating mode 2

GENERAL EMERGENCY SITE AREA EMERGENCY ALERT UNUSUAL EVENT Loss of all Table C-4 onsite communication methods OR Loss of all Table C-4 offsite communication methods OR Loss of all Table C-4 NRC communication methods Hazardous event affecting a SAFETY SYSTEM needed for the current operating mode CA6.1 EAL - COLD MODES 5, 6 & Defueled None None None None None None Loss of Vital DC Power 4

None None None 5

6 5

6 DEF 5

6 5

6 5

6 5

6 DEF 5

6 5

6 5

6 5

6 DEF 5

6 Table C-5 Hazardous Events Seismic event (earthquake)

Internal or external FLOODING event High winds or tornado strike FIRE EXPLOSION Other events with similar hazard characteristics as determined by the Shift Manager

  • RMWST
  • Recycle Holdup Tank Table C-1 Sumps / Tanks CS1.1 With CONTAINMENT CLOSURE not established, RCS level

< 70% RVLIS Full Range CS1.2 With CONTAINMENT CLOSURE established, RCS level

< 63% RVLIS Full Range CG1.1 RCS level < 63% RVLIS Full Range for ³ 30 min. (Note 1)

AND Any Containment Challenge indication, Table C-2

  • Containment Closure not established (Note 6)
  • Containment hydrogen concentration ³ 4%
  • Unplanned rise in Containment pressure Table C-2 Containment Challenge Indications 60 min.*

20 min.*

If an RCS heat removal system is in operation within this time frame and RCS temperature is being reduced, the EAL is not applicable 0 min.

Table C-3 RCS Heat-up Duration Thresholds Not intact OR At REDUCED INVENTORY Intact (but not REDUCED INVENTORY)

RCS Status Containment Closure Status Heat-up Duration N/A established not established Prepared for Duke Energy by: Operations Support Services, Inc. - www.ossi-net.com (1/21/16)

Modes:

1 Power Operations Defueled DEF 2

Startup 5

Cold Shutdown 3

Hot Standby 4

Hot Shutdown Harris Nuclear Plant Classification of Emergency EP-EAL Matrix Revision 1 6

Refuel Table C-4 Communication Methods Onsite Offsite System PABX telephone (desk phones)

HE&EC PABX telephone Site paging system Satellite phone DEMNET Radio communications networks NRC ETS phone NRC HPN phone X

X X

X NRC X

X X

X X

X X

X RVLIS Full Range Plant El.

260.62' 70%

63%

252.04' Standpipe 0"

89%

249.01' Reactor Vessel Flange 6 in. < Bottom of Hotleg Top of Active Fuel RCS Levels Note 1: The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 2: If an ongoing release is detected and the release start time is unknown, assume that the release duration has exceeded the specified time limit.

Note 3: If the effluent flow past an effluent monitor is known to have stopped, indicating that the release path is isolated, the effluent monitor reading is no longer VALID for classification purposes.

Note 4: The pre-calculated effluent monitor values presented in EALs RA1.1, RS1.1 and RG1.1 should be used for emergency classification assessments until the results from a dose assessment using actual meteorology are available. If dose assessment results are available, declaration should be based on dose assessment instead of radiation monitor values.

Note 5: If the equipment in the listed room or area was already inoperable or out-of-service before the event occurred, then no emergency classification is warranted.

Note 6: If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Note 7: This EAL does not apply to routine traffic impediments such as fog, snow, ice, or vehicle breakdowns or accidents.

Note 8: A manual trip action is any operator action, or set of actions, which causes the control rods to be rapidly inserted into the core, and does not include manually driving in control rods or implementation of boron injection strategies.

NOTES RHR Pump Operations

- 82" 253.75' Table C-6 AC Power Sources Offsite

- SUT 1A

- SUT 1B

- UAT 1A/1B backfed via Main Transformer (only if already aligned)

Onsite

- EDG 1A-SA

- EDG 1B-SB Irradiated Fuel Event RU1.1 Sample analysis for a gaseous or liquid release indicates a concentration or release rate > 2 x ODCM limits for ³ 60 min.

(Notes 1, 2)

RU1.2 Reading on any Table R-1 effluent radiation monitor

> column UE for ³ 60 min. (Notes 1, 2, 3)

RA1.1 Dose assessment using actual meteorology indicates doses

> 10 mrem TEDE or 50 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RS1.1 Reading on any Table R-1 effluent radiation monitor > column SAE for ³ 15 min. (Notes 1, 2, 3, 4)

RS1.2 Dose assessment using actual meteorology indicates doses

> 100 mrem TEDE or 500 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RA1.2 Reading on any Table R-1 effluent radiation monitor

> column ALERT for ³ 15 min. (Notes 1, 2, 3, 4)

RA1.3 Analysis of a liquid effluent sample indicates a concentration or release rate that would result in doses > 10 mrem TEDE or 50 mrem thyroid CDE at or beyond the SITE BOUNDARY for 60 min. of exposure (Notes 1, 2)

RU2.1 UNPLANNED water level drop in the REFUELING PATHWAY as indicated by low water level alarm or indication (LI-01SF-5101A/LI-01SF-5102A/LI-01SF-5103A, LI-403 or RCS standpipe)

AND UNPLANNED rise in corresponding area radiation levels as indicated by any Table R-2 area radiation monitors RA2.2 Damage to irradiated fuel resulting in a release of radioactivity from the fuel as indicated by high alarm on any of the following:

- Table R-2 refueling pathway area radiation monitors

- 1REM-*1FL-3508A-SA, FHB Emergency Exhaust

- 1REM-*1FL-3508B-SB, FHB Emergency Exhaust RA3.1 Dose rates > 15 mR/hr in EITHER of the following areas:

Control Room (RM-21RR-3560-SA)

OR Central Alarm Station (by survey)

Release of gaseous or liquid radioactivity greater than 2 times the ODCM limits for 60 minutes or longer Release of gaseous or liquid radioactivity resulting in offsite dose greater than 10 mrem TEDE or 50 mrem thyroid CDE Release of gaseous radioactivity resulting in offsite dose greater than 100 mrem TEDE or 500 mrem thyroid CDE Release of gaseous radioactivity resulting in offsite dose greater than 1,000 mrem TEDE or 5,000 mrem thyroid CDE Unplanned loss of water level above irradiated fuel Significant lowering of water level above, or damage to, irradiated fuel RA2.1 Uncovery of irradiated fuel in the REFUELING PATHWAY Radiation levels that IMPEDE access to equipment necessary for normal plant operations, cooldown or shutdown RS1.3 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 100 mR/hr expected to con-tinue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 500 mrem for 60 min. of inhalation.

(Notes 1, 2)

Abnorm.

Rad Levels

/ Rad Effluent R

GENERAL EMERGENCY SITE AREA EMERGENCY ALERT UNUSUAL EVENT 2

Rad Effluent 1

None None None None HS1.1 A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the Security Shift Supervision HG1.1 A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the Security Shift Supervision AND EITHER of the following has occurred:

Any of the following safety functions cannot be controlled or maintained

- Reactivity

- Core Cooling

- RCS heat removal OR Damage to spent fuel has occurred or is IMMINENT HU2.1 HU4.1 A FIRE is not extinguished within 15 min. of any of the following FIRE detection indications (Note 1):

- Report from the field (i.e., visual observation)

- Receipt of multiple (more than 1) fire alarms or indications

- Field verification of a single fire alarm AND The FIRE is located within any Table H-1 area HA5.1 Release of a toxic, corrosive, asphyxiant or flammable gas into any Table R-3/H-2 rooms or areas AND Entry into the room or area is prohibited or IMPEDED (Note 5)

Seismic event greater than OBE levels HU4.2 Receipt of a single fire alarm (i.e., no other indications of a FIRE)

AND The fire alarm is indicating a FIRE within any Table H-1 area AND The existence of a FIRE is not verified within 30 min. of alarm receipt (Note 1)

HU3.2 Internal room or area FLOODING of a magnitude sufficient to require manual or automatic electrical isolation of a SAFETY SYSTEM component needed for the current operating mode FIRE potentially degrading the level of safety of the plant Gaseous release IMPEDING access to equipment necessary for normal plant operations, cooldown or shutdown Confirmed SECURITY CONDITION or threat HU7.1 Other conditions existing that in the judgment of the Emergency Coordinator warrant declaration of a UE Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant or indicate a security threat to facility protection has been initiated. No releases of radioactive material requiring offsite response or monitoring are expected unless further degradation of SAFETY SYSTEMS occurs.

An event has resulted in plant control being transferred from the Control Room to the Auxiliary Control Panel HA6.1 Control Room evacuation resulting in transfer of plant control to alternate locations HS6.1 An event has resulted in plant control being transferred from the Control Room to the Auxiliary Control Panel AND Control of any of the following key safety functions is not reestablished within 15 min. (Note 1):

- Reactivity

- Core Cooling

- RCS heat removal Inability to control a key safety function from outside the Control Room Other conditions exist which, in the judgment of the Emergency Coordinator, indicate that events are in progress or have occurred which involve an actual or potential substantial degradation of the level of safety of the plant or a security event that involves probable life threatening risk to site personnel or damage to site equipment because of HOSTILE ACTION. Any releases are expected to be limited to small fractions of the EPA Protective Action Guideline exposure levels.

HA7.1 Other conditions exist that in the judgment of the Emergency Coordinator warrant declaration of an Alert HS7.1 Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which involve actual or likely major failures of plant functions needed for protection of the public or HOSTILE ACTION that results in intentional damage or malicious acts, (1) toward site personnel or equipment that could lead to the likely failure of or, (2) that prevent effective access to equipment needed for the protection of the public.

Any releases are not expected to result in exposure levels which exceed EPA Protective Action Guideline exposure levels beyond the SITE BOUNDARY.

Other conditions existing that in the judgment of the Emergency Coordinator warrant declaration of a Site Area Emergency HG7.1 Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which involve actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity or HOSTILE ACTION that results in an actual loss of physical control of the facility. Releases can be reasonably expected to exceed EPA Protective Action Guideline exposure levels offsite for more than the immediate site area Other conditions exist which in the judgment of the Emergency Coordinator warrant declaration of a General Emergency None Hazards H

Seismic Event Fire Control Room Evacuation Hazardous Gases Security EC Judgment 2

4 5

1 6

7 None HU3.3 Movement of personnel within the PROTECTED AREA is IMPEDED due to an offsite event involving hazardous materials (e.g., an offsite chemical spill or toxic gas release)

Area Rad Levels 3

RA1.4 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 10 mR/hr expected to continue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 50 mrem for 60 min. of inhalation.

(Notes 1, 2)

RG1.1 Reading on any Table R-1 effluent radiation monitor > column GE for ³ 15 min. (Notes 1, 2, 3, 4)

RG1.2 Dose assessment using actual meteorology indicates doses

> 1000 mrem TEDE or 5000 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RG1.3 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 1000 mR/hr expected to con-tinue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 5000 mrem for 60 min. of inhalation.

(Notes 1, 2)

RA3.2 An UNPLANNED event results in radiation levels that prohibit or IMPEDE access to any Table R-3/H-2 rooms or areas (Note 5)

HU3.1 A tornado strike within the PROTECTED AREA Hazardous event HU3.4 A hazardous event that results in on-site conditions sufficient to prohibit the plant staff from accessing the site via personal vehicles (Note 7)

Natural or Tech.

Hazard 3

HU4.3 A FIRE within the plant PROTECTED AREA not extinguished within 60 min. of the initial report, alarm or indication (Note 1)

HU4.4 A FIRE within the plant PROTECTED AREA that requires firefighting support by an offsite fire response agency to extinguish None None None None None None None RA2.3 Lowering of spent fuel pool level < 270.7 ft. (Level 2)

RS2.1 Lowering of spent fuel pool level < 260.7 ft. (Level 3)

RG2.1 Spent fuel pool level at the top of the fuel racks Spent fuel pool level cannot be restored to at least the top of the fuel racks for 60 minutes or longer Spent fuel pool level cannot be restored to at least 260.7 ft.

(Level 3) for > 60 min. (Note 1) 5 6

1 2

3 4

DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF Table R-2 Refueling Pathway AreaRadiation Monitors Containment RM-1CR-3561A-SA Containment Ventilation Isolation RM-1CR-3561B-SB Containment Ventilation Isolation RM-1CR-3561C-SA Containment Ventilation Isolation RM-1CR-3561D-SB Containment Ventilation Isolation Fuel Handling Building RM-1FR-3564A-SA Spent Fuel Pool SW, SE, SW RM-1FR-3564B-SB Spent Fuel Pool SW, SE, SE RM-1FR-3565A-SA Spent Fuel Pool SW, SE, SW RM-1FR-3565B-SB Spent Fuel Pool SW, SE, SE RM-1FR-3566A-SA Spent Fuel Pool NE, NW, NE RM-1FR-3566B-SB Spent Fuel Pool NW, NE, NW RM-1FR-3567A-SA Spent Fuel Pool NW, NE, NW RM-1FR-3567B-SB Spent Fuel Pool NE, NW, NE Seismic event > OBE as indicated by any of the following:

ALB-10/4-4, SEISMIC MON SYS OBE EXCEEDED is ALARMED ALARM light on Seismic Switch Power Supply is LIT Any red alarm light is LIT on the Response Spectrum Annunciator

[Refer to EAL CA6.1 OR SA9.1 for escalation due to seismic event]

[Refer to EAL CA6.1 OR SA9.1 for escalation due to natural or technological hazard]

[Refer to EAL CA6.1 OR SA9.1 for escalation due to FIRE]

None Note 1: The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 2: If an ongoing release is detected and the release start time is unknown, assume that the release duration has exceeded the specified time limit.

Note 3: If the effluent flow past an effluent monitor is known to have stopped, indicating that the release path is isolated, the effluent monitor reading is no longer VALID for classification purposes.

Note 4: The pre-calculated effluent monitor values presented in EALs RA1.1, RS1.1 and RG1.1 should be used for emergency classification assessments until the results from a dose assessment using actual meteorology are available. If dose assessment results are available, declaration should be based on dose assessment instead of radiation monitor values.

Note 5: If the equipment in the listed room or area was already inoperable or out-of-service before the event occurred, then no emergency classification is warranted.

Note 6: If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Note 7: This EAL does not apply to routine traffic impediments such as fog, snow, ice, or vehicle breakdowns or accidents.

Note 8: A manual trip action is any operator action, or set of actions, which causes the control rods to be rapidly inserted into the core, and does not include manually driving in control rods or implementation of boron injection strategies.

NOTES Gaseous Liquid Table R-1 Effluent Monitor Classification Thresholds Release Point Monitor GE SAE Alert UE Plant Vent 1.05E+8 mCi/sec Secondary Waste Sample Tank Discharge Turbine Building Treated Laundry & Hot Shower Tank Discharge Waste Monitor/Waste Evaporator Condensate Tank Discharge RM-21AV-3509-1SA RM-1TV-3536-1 REM-1WL-3540 REM-21WL-3541 REM-21WS-3542 4.60E+8 mCi/sec 1.05E+7 mCi/sec 4.60E+7 mCi/sec 1.05E+6 mCi/sec 4.60E+6 mCi/sec 1.14E+4 mCi/sec 1.38E+4 mCi/sec 7.02E-04 mCi/ml 1.97E-03 mCi/ml 7.02E-04 mCi/ml Waste Process Building Vent 5 RM-1WV-3546-1 2.49E+5 mCi/sec Waste Process Building Vent 5A RM-1WV-3547-1 1.45E+4 mCi/sec 7.74E+9 mCi/sec 7.76E+9 mCi/sec 7.74E+8 mCi/sec 7.76E+8 mCi/sec 7.75E+7 mCi/sec 7.76E+7 mCi/sec None Table R-3/H-2 Safe Operation & Shutdown Rooms/Areas Room / Area Mode(s)

- RAB 190 (RHR pumps)

- RAB 216 (BIT)

- RAB 236 (CSIP, Primary Sample Sink, AFW pumps, CCW pumps and HX, Boric Acid Transfer Pumps, Mezzanine Area)

- RAB 261 (RHR Heat Exchangers, Demin. Valve Gallery, VCT Valve Gallery)

- RAB 286 (Switchgear)

- Steam Tunnel

- ESW intakes 4

1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4 1, 2, 3, 4, 5

  • Containment
  • Reactor Auxiliary Building
  • Diesel Fuel Oil Storage Building (DFOST)
  • ESW Intake Structure and Auxiliary Reservoir Intake Structure Table H-1 Fire Areas HU1.1 A SECURITY CONDITION that does not involve a HOSTILE ACTION as reported by the Security Shift Supervision HA1.1 A HOSTILE ACTION is occurring or has occurred within the OWNER CONTROLLED AREA as reported by the Security Shift Supervision Notification of a credible security threat directed at the site A validated notification from the NRC providing information of an aircraft threat to the site HU1.2 HU1.3 A validated notification from NRC of an aircraft attack threat within 30 min. of the site HA1.2 HOSTILE ACTION within the OWNER CONTROLLED AREA or airborne attack threat within 30 minutes HOSTILE ACTION within the PROTECTED AREA HOSTILE ACTION resulting in loss of physical control of the facility Confirmed SECURITY CONDITION or threat Replace with: "A Containment Ventilation Isolation Radiation Monitor > 2.6E+04 mR/hr (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB)"

Prepared for Duke Energy by: Operations Support Services, Inc. - www.ossi-net.com (1/21/16)

Modes:

1 Power Operations Defueled DEF 2

Startup 5

Cold Shutdown 3

Hot Standby 4

Hot Shutdown Harris Nuclear Plant Classification of Emergency EP-EAL Matrix Revision 1 Irradiated Fuel Event RU1.1 Sample analysis for a gaseous or liquid release indicates a concentration or release rate > 2 x ODCM limits for ³ 60 min.

(Notes 1, 2)

RU1.2 Reading on any Table R-1 effluent radiation monitor

> column UE for ³ 60 min. (Notes 1, 2, 3)

RA1.1 Dose assessment using actual meteorology indicates doses

> 10 mrem TEDE or 50 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RS1.1 Reading on any Table R-1 effluent radiation monitor > column SAE for ³ 15 min. (Notes 1, 2, 3, 4)

RS1.2 Dose assessment using actual meteorology indicates doses

> 100 mrem TEDE or 500 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RA1.2 Reading on any Table R-1 effluent radiation monitor

> column ALERT for ³ 15 min. (Notes 1, 2, 3, 4)

RA1.3 Analysis of a liquid effluent sample indicates a concentration or release rate that would result in doses > 10 mrem TEDE or 50 mrem thyroid CDE at or beyond the SITE BOUNDARY for 60 min. of exposure (Notes 1, 2)

RU2.1 UNPLANNED water level drop in the REFUELING PATHWAY as indicated by low water level alarm or indication (LI-01SF-5101A/LI-01SF-5102A/LI-01SF-5103A, LI-403 or RCS standpipe)

AND UNPLANNED rise in corresponding area radiation levels as indicated by any Table R-2 area radiation monitors RA2.2 Damage to irradiated fuel resulting in a release of radioactivity from the fuel as indicated by high alarm on any of the following:

- Table R-2 refueling pathway area radiation monitors

- 1REM-*1FL-3508A-SA, FHB Emergency Exhaust

- 1REM-*1FL-3508B-SB, FHB Emergency Exhaust RA3.1 Dose rates > 15 mR/hr in EITHER of the following areas:

Control Room (RM-21RR-3560-SA)

OR Central Alarm Station (by survey)

Release of gaseous or liquid radioactivity greater than 2 times the ODCM limits for 60 minutes or longer Release of gaseous or liquid radioactivity resulting in offsite dose greater than 10 mrem TEDE or 50 mrem thyroid CDE Release of gaseous radioactivity resulting in offsite dose greater than 100 mrem TEDE or 500 mrem thyroid CDE Release of gaseous radioactivity resulting in offsite dose greater than 1,000 mrem TEDE or 5,000 mrem thyroid CDE Unplanned loss of water level above irradiated fuel Significant lowering of water level above, or damage to, irradiated fuel RA2.1 Uncovery of irradiated fuel in the REFUELING PATHWAY Radiation levels that IMPEDE access to equipment necessary for normal plant operations, cooldown or shutdown RS1.3 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 100 mR/hr expected to con-tinue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 500 mrem for 60 min. of inhalation.

(Notes 1, 2)

Abnorm.

Rad Levels

/ Rad Effluent R

GENERAL EMERGENCY SITE AREA EMERGENCY ALERT UNUSUAL EVENT 2

Rad Effluent 1

None None None None HS1.1 A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the Security Shift Supervision HG1.1 A HOSTILE ACTION is occurring or has occurred within the PROTECTED AREA as reported by the Security Shift Supervision AND EITHER of the following has occurred:

Any of the following safety functions cannot be controlled or maintained

- Reactivity

- Core Cooling

- RCS heat removal OR Damage to spent fuel has occurred or is IMMINENT HU1.1 A SECURITY CONDITION that does not involve a HOSTILE ACTION as reported by the Security Shift Supervision HA1.1 HU2.1 HU4.1 A FIRE is not extinguished within 15 min. of any of the following FIRE detection indications (Note 1):

- Report from the field (i.e., visual observation)

- Receipt of multiple (more than 1) fire alarms or indications

- Field verification of a single fire alarm AND The FIRE is located within any Table H-1 area HA5.1 Release of a toxic, corrosive, asphyxiant or flammable gas into any Table R-3/H-2 rooms or areas AND Entry into the room or area is prohibited or IMPEDED (Note 5)

Seismic event greater than OBE levels HU4.2 Receipt of a single fire alarm (i.e., no other indications of a FIRE)

AND The fire alarm is indicating a FIRE within any Table H-1 area AND The existence of a FIRE is not verified within 30 min. of alarm receipt (Note 1)

HU3.2 Internal room or area FLOODING of a magnitude sufficient to require manual or automatic electrical isolation of a SAFETY SYSTEM component needed for the current operating mode FIRE potentially degrading the level of safety of the plant Gaseous release IMPEDING access to equipment necessary for normal plant operations, cooldown or shutdown Confirmed SECURITY CONDITION or threat HOSTILE ACTION within the OWNER CONTROLLED AREA or airborne attack threat within 30 minutes HOSTILE ACTION within the PROTECTED AREA HOSTILE ACTION resulting in loss of physical control of the facility HU7.1 Other conditions existing that in the judgment of the Emergency Coordinator warrant declaration of a UE Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which indicate a potential degradation of the level of safety of the plant or indicate a security threat to facility protection has been initiated. No releases of radioactive material requiring offsite response or monitoring are expected unless further degradation of SAFETY SYSTEMS occurs.

An event has resulted in plant control being transferred from the Control Room to the Auxiliary Control Panel HA6.1 Control Room evacuation resulting in transfer of plant control to alternate locations HS6.1 An event has resulted in plant control being transferred from the Control Room to the Auxiliary Control Panel AND Control of any of the following key safety functions is not reestablished within 15 min. (Note 1):

- Reactivity

- Core Cooling

- RCS heat removal Inability to control a key safety function from outside the Control Room Other conditions exist which, in the judgment of the Emergency Coordinator, indicate that events are in progress or have occurred which involve an actual or potential substantial degradation of the level of safety of the plant or a security event that involves probable life threatening risk to site personnel or damage to site equipment because of HOSTILE ACTION. Any releases are expected to be limited to small fractions of the EPA Protective Action Guideline exposure levels.

HA7.1 Other conditions exist that in the judgment of the Emergency Coordinator warrant declaration of an Alert HS7.1 Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which involve actual or likely major failures of plant functions needed for protection of the public or HOSTILE ACTION that results in intentional damage or malicious acts, (1) toward site personnel or equipment that could lead to the likely failure of or, (2) that prevent effective access to equipment needed for the protection of the public.

Any releases are not expected to result in exposure levels which exceed EPA Protective Action Guideline exposure levels beyond the SITE BOUNDARY.

Other conditions existing that in the judgment of the Emergency Coordinator warrant declaration of a Site Area Emergency HG7.1 Other conditions exist which in the judgment of the Emergency Coordinator indicate that events are in progress or have occurred which involve actual or IMMINENT substantial core degradation or melting with potential for loss of containment integrity or HOSTILE ACTION that results in an actual loss of physical control of the facility. Releases can be reasonably expected to exceed EPA Protective Action Guideline exposure levels offsite for more than the immediate site area Other conditions exist which in the judgment of the Emergency Coordinator warrant declaration of a General Emergency None Hazards H

Seismic Event Fire Control Room Evacuation Hazardous Gases Security EC Judgment 2

4 5

1 6

7 None HU3.3 Movement of personnel within the PROTECTED AREA is IMPEDED due to an offsite event involving hazardous materials (e.g., an offsite chemical spill or toxic gas release)

A HOSTILE ACTION is occurring or has occurred within the OWNER CONTROLLED AREA as reported by the Security Shift Supervision GENERAL EMERGENCY SITE AREA EMERGENCY ALERT UNUSUAL EVENT Area Rad Levels 3

RA1.4 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 10 mR/hr expected to continue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 50 mrem for 60 min. of inhalation.

(Notes 1, 2)

RG1.1 Reading on any Table R-1 effluent radiation monitor > column GE for ³ 15 min. (Notes 1, 2, 3, 4)

RG1.2 Dose assessment using actual meteorology indicates doses

> 1000 mrem TEDE or 5000 mrem thyroid CDE at or beyond the SITE BOUNDARY (Note 4)

RG1.3 Field survey results indicate EITHER of the following at or beyond the SITE BOUNDARY:

- Closed window dose rates > 1000 mR/hr expected to con-tinue for ³ 60 min.

- Analyses of field survey samples indicate thyroid CDE

> 5000 mrem for 60 min. of inhalation.

(Notes 1, 2)

RA3.2 An UNPLANNED event results in radiation levels that prohibit or IMPEDE access to any Table R-3/H-2 rooms or areas (Note 5)

HU3.1 A tornado strike within the PROTECTED AREA Hazardous event HU3.4 A hazardous event that results in on-site conditions sufficient to prohibit the plant staff from accessing the site via personal vehicles (Note 7)

Natural or Tech.

Hazard 3

HU4.3 A FIRE within the plant PROTECTED AREA not extinguished within 60 min. of the initial report, alarm or indication (Note 1)

HU4.4 A FIRE within the plant PROTECTED AREA that requires firefighting support by an offsite fire response agency to extinguish None None None None None None None Table F-1 Fission Product Barrier Threshold Matrix Containment (CNMT) Barrier Fuel Clad (FC) Barrier Reactor Coolant System (RCS) Barrier Loss Potential Loss Loss Loss Potential Loss Potential Loss A. RCS or SG Tube Leakage B. Inadequate Heat Removal C. CNMT Radiation /

RCS Activity D. CNMT Integrity or Bypass None None None None None

1. Any condition in the opinion of the Emergency Coordinator that indicates loss of the Fuel Clad barrier
1. Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the Fuel Clad barrier
1. An automatic or manual ECCS (SI) actuation required by EITHER:
  • UNISOLABLE RCS leakage
  • SG tube RUPTURE
1. Any condition in the opinion of the Emergency Coordinator that indicates loss of the RCS barrier
1. Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the RCS barrier
1. Any condition in the opinion of the Emergency Coordinator that indicates loss of the Containment barrier
1. Any condition in the opinion of the Emergency Coordinator that indicates potential loss of the Containment barrier None None None E. EC Judgment
1. Operation of a standby charging pump is required due to EITHER:
  • UNISOLABLE RCS leakage
  • SG tube leakage
2. CSFST Integrity-RED Path entry conditions met
1. A leaking or RUPTURED SG is FAULTED outside of containment
1. CSFST Core Cooling-RED Path entry conditions met
1. CSFST Core Cooling-ORANGE Path entry conditions met
2. CSFST Heat Sink-RED Path entry conditions met AND Heat Sink is required None
1. CSFST Heat Sink-RED Path entry conditions met AND Heat Sink is required
1. CSFST Core Cooling-RED Path entry conditions met AND Restoration procedures not effective within 15 min. (Note 1)
1. Containment radiation >150 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)
2. Dose equivalent I-131 coolant activity > 300 Ci/gm
1. Containment Leak Detection Monitor Noble Gas (REM-1LT-3502A-SA) > 8.3E-3 Ci/ml
1. Containment radiation > 600 R/hr (RM-1CR-3589-SA or RM-1CR-3590-SB)

None None None

1. Containment isolation is required AND EITHER Containment integrity has been lost based on Emergency Coordinator judgment UNISOLABLE pathway from Containment to the environment exists
2. Indications of RCS leakage outside of containment
1. CSFST Containment-RED Path entry conditions met
2. Containment hydrogen concentration > 4%
3. Containment pressure > 10 psig with

< one full train of depressurization equipment operating (one CNMT spray pump and two CNMT fan coolers) per design for > 15 min.(Note 1)

System Malfunct.

SA1.1 AC power capability, Table S-5, to 6.9 KV emergency buses 1A-SA and 1B-SB reduced to a single power source for

³ 15 min. (Note 1)

AND Any additional single power source failure will result in loss of all AC power to SAFETY SYSTEMS SG1.1 None None Fission Product Barriers FS1.1 Loss of any two barriers AND Loss or potential loss of third barrier (Table F-1)

Loss or potential loss of any two barriers (Table F-1)

FA1.1 Any loss or any potential loss of either Fuel Clad or RCS (Table F-1)

FG1.1 SS1.1 Loss of Emergency AC Power Loss of all offsite AC power capability to emergency buses for 15 minutes or longer SU1.1 Loss of all offsite AC power capability, Table S-5, to 6.9 KV emergency buses 1A-SA and 1B-SB for ³ 15 min. (Note 1)

Loss of all but one AC power source to emergency buses for 15 minutes or longer Loss of all offsite and all onsite AC power to emergency buses for 15 minutes or longer Prolonged loss of all offsite and all onsite AC power to emergency buses Loss of all 125 VDC power based on battery bus voltage indications < 105 VDC on both emergency DC buses (DP-1A-SA, DP-1B-SB) for ³ 15 min. (Note 1)

SS2.1 Loss of all vital DC power for 15 minutes or longer SA6.1 An automatic or manual trip fails to shut down the reactor as indicated by reactor power ³ 5%

AND Manual trip actions taken at the reactor control console (actuation of MCB Reactor Trip Switch #1, #2 or MCB Turbine Trip switch) are not successful in shutting down the reactor as indicated by reactor power ³ 5% (Note 8)

An automatic or manual trip fails to shut down the reactor as indicated by reactor power ³ 5%

AND All actions to shut down the reactor are not successful as indicated by reactor power ³ 5%

AND EITHER:

Core Cooling RED Path entry conditions met Heat Sink RED Path entry conditions met SS6.1 Automatic or manual trip fails to shut down the reactor and subsequent manual actions taken at the reactor control consoles are not successful in shutting down the reactor Inability to shut down the reactor causing a challenge to core cooling or RCS heat removal Loss of all onsite or offsite communications capabilities SU7.1 Loss of CR Indications UNPLANNED loss of Control Room indications for 15 minutes or longer SU3.1 An UNPLANNED event results in the inability to monitor one or more Table S-1 parameters from within the Control Room for ³ 15 min. (Note 1)

SA3.1 An UNPLANNED event results in the inability to monitor one or more Table S-1 parameters from within the Control Room for ³ 15 min. (Note 1)

AND Any significant transient is in progress, Table S-2 UNPLANNED loss of Control Room indications for 15 minutes or longer with a significant transient in progress Hazardous event affecting a SAFETY SYSTEM needed for the current operating mode SA9.1 The occurrence of any Table S-4 hazardous event AND EITHER:

Event damage has caused indications of degraded performance in at least one train of a SAFETY SYSTEM needed for the current operating mode The event has caused VISIBLE DAMAGE to a SAFETY SYSTEM component or structure needed for the current operating mode RCS activity greater than Technical Specification allowable limits SU4.1 RCS activity > Technical Specification Section 3.4.8 limits RCS leakage for 15 minutes or longer SU5.1 RCS unidentified or pressure boundary leakage

> 10 gpm for ³ 15 min.

OR RCS identified leakage > 25 gpm for ³ 15 min.

OR Leakage from the RCS to a location outside containment

> 25 gpm for ³ 15 min.

(Note 1)

Automatic or manual trip fails to shut down the reactor SU6.1 None Loss of all offsite and all onsite AC power capability to 6.9 KV emergency buses 1A-SA and 1B-SB for ³ 15 min.

(Note 1)

Loss of all offsite and all onsite AC power capability to 6.9 KV emergency buses 1A-SA and 1B-SB AND EITHER:

- Restoration of at least one emergency bus in < 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is not likely

- Core Cooling RED Path entry conditions met F

S 1

3 9

Loss of Comm.

7 An automatic trip did not shut down the reactor as indicated by reactor power ³ 5% after any RPS setpoint is exceeded AND A subsequent automatic trip or manual trip action taken at the reactor control console (actuation of MCB Reactor Trip Switch #1, #2 or MCB Turbine Trip switch) is successful in shutting down the reactor as indicated by reactor power < 5% (Note 8)

None None None None None Loss of Vital DC Power 2

EAL-HOT MODES 1, 2, 3 & 4 SG1.2 Loss of all offsite and all onsite AC power capability to 6.9 KV emergency buses 1A-SA and 1B-SB for ³ 15 min.

AND Loss of all 125 VDC power based on battery bus voltage indications < 105 VDC on both emergency DC buses (DP-1A-SA, DP-1B-SB) for ³ 15 min.

(Note 1)

None RCS Activity 4

RPS Failure 6

RCS Leakage 5

None None None SU6.2 A manual trip did not shut down the reactor as indicated by reactor power ³ 5% after any manual trip action was initiated AND A subsequent automatic trip or manual trip action taken at the reactor control console (actuation of MCB Reactor Trip Switch

  1. 1, #2 or MCB Turbine Trip switch) is successful in shutting down the reactor as indicated by reactor power < 5% (Note 8)

Loss of all Table S-3 onsite communication methods OR Loss of all Table S-3 offsite communication methods OR Loss of all Table S-3 NRC communication methods Hazardous Event Affecting Safety Systems None Table S-1 Safety System Parameters

- Reactor power

- RCS level

- RCS pressure

- Core exit T/C temperature

- Level in at least one S/G

- Auxiliary feed flow in at least one S/G RA2.3 Lowering of spent fuel pool level < 270.7 ft. (Level 2)

RS2.1 Lowering of spent fuel pool level < 260.7 ft. (Level 3)

RG2.1 Spent fuel pool level at the top of the fuel racks Spent fuel pool level cannot be restored to at least the top of the fuel racks for 60 minutes or longer Spent fuel pool level cannot be restored to at least 260.7 ft.

(Level 3) for > 60 min. (Note 1) 5 6

1 2

3 4

DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 5

6 1

2 3

4 DEF 6

Refuel 1

2 3

4 1

1 2

3 4

1 2

3 4

1 2

3 4

1 2

3 4

1 2

3 4

1 2

3 4

1 2

3 4

1 2

3 4

1 1

1 2

3 4

Failure to isolate containment or loss of containment pressure control SU8.1 EITHER:

Any penetration is not isolated within 15 min. of a VALID containment isolation signal OR Containment pressure > 10 psig with < one full train of depressurization equipment operating (one CNMT spray pump and two CNMT fan coolers) per design for > 15 min.

(Note 1) 1 2

3 4

1 2

3 4

Table S-4 Hazardous Events Seismic event (earthquake)

Internal or external FLOODING event High winds or tornado strike FIRE EXPLOSION Other events with similar hazard characteristics as determined by the Shift Manager CNMT Failure 8

None None Loss of all emergency AC and vital DC power sources for 15 minutes or longer 1

2 3

4 1

2 3

4 1

2 3

4 1

2 3

4 None Table R-2 Refueling Pathway AreaRadiation Monitors Containment RM-1CR-3561A-SA Containment Ventilation Isolation RM-1CR-3561B-SB Containment Ventilation Isolation RM-1CR-3561C-SA Containment Ventilation Isolation RM-1CR-3561D-SB Containment Ventilation Isolation Fuel Handling Building RM-1FR-3564A-SA Spent Fuel Pool SW, SE, SW RM-1FR-3564B-SB Spent Fuel Pool SW, SE, SE RM-1FR-3565A-SA Spent Fuel Pool SW, SE, SW RM-1FR-3565B-SB Spent Fuel Pool SW, SE, SE RM-1FR-3566A-SA Spent Fuel Pool NE, NW, NE RM-1FR-3566B-SB Spent Fuel Pool NW, NE, NW RM-1FR-3567A-SA Spent Fuel Pool NW, NE, NW RM-1FR-3567B-SB Spent Fuel Pool NE, NW, NE Seismic event > OBE as indicated by any of the following:

ALB-10/4-4, SEISMIC MON SYS OBE EXCEEDED is ALARMED ALARM light on Seismic Switch Power Supply is LIT Any red alarm light is LIT on the Response Spectrum Annunciator Table S-3 Communication Methods Onsite Offsite System PABX telephone (desk phones)

HE&EC PABX telephone Site paging system Satellite phone DEMNET Radio communications networks NRC ETS phone NRC HPN phone X

X X

X NRC X

X X

X X

X X

X

[Refer to EAL CA6.1 OR SA9.1 for escalation due to seismic event]

[Refer to EAL CA6.1 OR SA9.1 for escalation due to natural or technological hazard]

[Refer to EAL CA6.1 OR SA9.1 for escalation due to FIRE]

SU4.2 Valid Gross Failed Fuel Detector (RS-7411A) high alarm

(> 1E+04 cpm)

None Note 1: The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 2: If an ongoing release is detected and the release start time is unknown, assume that the release duration has exceeded the specified time limit.

Note 3: If the effluent flow past an effluent monitor is known to have stopped, indicating that the release path is isolated, the effluent monitor reading is no longer VALID for classification purposes.

Note 4: The pre-calculated effluent monitor values presented in EALs RA1.1, RS1.1 and RG1.1 should be used for emergency classification assessments until the results from a dose assessment using actual meteorology are available. If dose assessment results are available, declaration should be based on dose assessment instead of radiation monitor values.

Note 5: If the equipment in the listed room or area was already inoperable or out-of-service before the event occurred, then no emergency classification is warranted.

Note 6: If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Note 7: This EAL does not apply to routine traffic impediments such as fog, snow, ice, or vehicle breakdowns or accidents.

Note 8: A manual trip action is any operator action, or set of actions, which causes the control rods to be rapidly inserted into the core, and does not include manually driving in control rods or implementation of boron injection strategies.

NOTES Note 1: The Emergency Coordinator should declare the event promptly upon determining that time limit has been exceeded, or will likely be exceeded.

Note 2: If an ongoing release is detected and the release start time is unknown, assume that the release duration has exceeded the specified time limit.

Note 3: If the effluent flow past an effluent monitor is known to have stopped, indicating that the release path is isolated, the effluent monitor reading is no longer VALID for classification purposes.

Note 4: The pre-calculated effluent monitor values presented in EALs RA1.1, RS1.1 and RG1.1 should be used for emergency classification assessments until the results from a dose assessment using actual meteorology are available. If dose assessment results are available, declaration should be based on dose assessment instead of radiation monitor values.

Note 5: If the equipment in the listed room or area was already inoperable or out-of-service before the event occurred, then no emergency classification is warranted.

Note 6: If CONTAINMENT CLOSURE is re-established prior to exceeding the 30-minute time limit, declaration of a General Emergency is not required.

Note 7: This EAL does not apply to routine traffic impediments such as fog, snow, ice, or vehicle breakdowns or accidents.

Note 8: A manual trip action is any operator action, or set of actions, which causes the control rods to be rapidly inserted into the core, and does not include manually driving in control rods or implementation of boron injection strategies.

NOTES None Table S-2 Significant Transients

- Reactor trip

- Runback > 25% thermal power

- Electrical load rejection > 25% electrical load

- Safety injection actuation

[Refer to fission product barrier EALs for escalation due to fuel clad failures]

[Refer to fission product barrier EALs for escalation due to RCS leakage]

Table R-3/H-2 Safe Operation & Shutdown Rooms/Areas Room / Area Mode(s)

- RAB 190 (RHR pumps)

- RAB 216 (BIT)

- RAB 236 (CSIP, Primary Sample Sink, AFW pumps, CCW pumps and HX, Boric Acid Transfer Pumps, Mezzanine Area)

- RAB 261 (RHR Heat Exchangers, Demin. Valve Gallery, VCT Valve Gallery)

- RAB 286 (Switchgear)

- Steam Tunnel

- ESW intakes 4

1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4, 5 1, 2, 3, 4 1, 2, 3, 4, 5 None Table S-5 AC Power Sources Offsite

- SUT 1A

- SUT 1B

- UAT 1A/1B backfed via Main Transformer (only if already aligned)

Onsite

- UAT 1A/1B via Main Generator

- EDG 1A-SA

- EDG 1B-SB Gaseous Liquid Table R-1 Effluent Monitor Classification Thresholds Release Point Monitor GE SAE Alert UE Plant Vent 1.05E+8 mCi/sec Secondary Waste Sample Tank Discharge Turbine Building Treated Laundry & Hot Shower Tank Discharge Waste Monitor/Waste Evaporator Condensate Tank Discharge RM-21AV-3509-1SA RM-1TV-3536-1 REM-1WL-3540 REM-21WL-3541 REM-21WS-3542 4.60E+8 mCi/sec 1.05E+7 mCi/sec 4.60E+7 mCi/sec 1.05E+6 mCi/sec 4.60E+6 mCi/sec 1.14E+4 mCi/sec 1.38E+4 mCi/sec 7.02E-04 mCi/ml 1.97E-03 mCi/ml 7.02E-04 mCi/ml Waste Process Building Vent 5 RM-1WV-3546-1 2.49E+5 mCi/sec Waste Process Building Vent 5A RM-1WV-3547-1 1.45E+4 mCi/sec 7.74E+9 mCi/sec 7.76E+9 mCi/sec 7.74E+8 mCi/sec 7.76E+8 mCi/sec 7.75E+7 mCi/sec 7.76E+7 mCi/sec Notification of a credible security threat directed at the site A validated notification from the NRC providing information of an aircraft threat to the site HU1.2 HU1.3 A validated notification from NRC of an aircraft attack threat within 30 min. of the site HA1.2 Confirmed SECURITY CONDITION or threat

  • Containment
  • Reactor Auxiliary Building
  • Diesel Fuel Oil Storage Building (DFOST)
  • ESW Intake Structure and Auxiliary Reservoir Intake Structure Table H-1 Fire Areas Revise to "1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column FC Barrier Loss" Revise to 1. " (RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB) > Table F-2 Column RCS Barrier Loss" Revise to "1. (RM-1CR-3589SA or RM-1CR-3590SB) > Table F-2 Column CNMT Potential Loss" Add INSERT A

INSERT A:

Table F-2 Containment Radiation Time After S/D FC Barrier Loss:

RM-1CR-3589SA or RM-1CR-3590SB RCS Barrier Loss:

RM-1CR-3561A-SA, RM-1CR-3561B-SB, RM-1CR-3561C-SA, or RM-1CR-3561D-SB CNMT Potential Loss:

RM-1CR-3589SA or RM-1CR-3590SB 0 - 1 hr 130 R/hr 1.37E+03 mR/hr 2360 R/hr 1 - 2 hrs 110 R/hr 1.12E+03 mR/hr 2000 R/hr 2 - 8 hrs 70 R/hr 6.35E+02 mR/hr 1300 R/hr

> 8 hrs 21 R/hr 1.37E+02 mR/hr 390 R/hr