UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Chapter:

15 Page:

1 of 2 LIST OF FIGURES FIGURE NUMBER TITLE FIGURE 15-1 PLANT SAFETY ANALYSIS METHOD FOR IDENTIFYING AND EVALUATING ABNORMAL OPERATIONAL TRANSIENTS FIGURE 15-2 PLANT SAFETY ANALYSIS METHOD FOR IDENTIFYING AND EVALUATING ACCIDENTS FIGURE 15-3 LOSS OF 100 DEGREE FEEDWATER HEATING MANUAL FLOW CONTROL, UNIT 2 -CYCLE 7 FIGURE 15-4 DELETED IN REVISION 21 FIGURE 15-5 FEEDWATER CONTROLLER FAILURE MAXIMUM DEMAND (EOC),

UNIT 1-CYCLE 21 FIGURE 15-6 DELETED IN REVISION 22.

FIGURE 15-7 FEEDWATER CONTROLLER FAILURE MAXIMUM DEMAND (EOC), UNIT 2 -

CYCLE 22 FIGURE 15-8 DELETED IN REVISION 22.

FIGURE 15-9 DELETED IN REVISION 22.

FIGURE 15-10 FEEDWATER CONTROLLER FAILURE WITH TBPOOS, ICF, AND NFWT, UNIT 2 - CURRENT CYCLE (EOC 22)

FIGURE 15-11 INADVERTENT HPCI ACTIVATION, UNIT 1 - CYCLE 9 (BOC9 TO EOC9)

FIGURE 15-12 INADVERTENT HPCI ACTIVATION, UNIT 2 - CYCLE 10 FIGURE 15-13 PRESSURE REGULATOR FAILURE (OPEN), UNIT 1 - CYCLE 1 FIGURE 15-14 PRESSURE REGULATOR FAILURE (OPEN), UNIT 2 - CYCLE 1 FIGURE 15-15 INADVERTENT OPENING OF A RELIEF OR SAFETY VALVE, UNIT 2 - CYCLE 1 FIGURE 15-16 GENERATOR LOAD REJECTION WITH 25 PERCENT BYPASS, UNIT 1 - CYCLE 1 FIGURE 15-17 GENERATOR LOAD REJECTION NO BYPASS WITH ICF, UNIT 1 - CURRENT CYCLE (EOC 21)

FIGURE 15-18 GENERATOR LOAD REJECTION, NO BYPASS, WITH ICF, UNIT 2 - (EOC 22)

FIGURE 15-19 TURBINE TRIP WITH 25 PERCENT BYPASS, UNIT 1 - CYCLE 1 FIGURE 15-20 TURBINE TRIP WITHOUT BYPASS WITH ICF, UNIT 1 - CURRENT CYCLE (EOC 21)

FIGURE 15-21 TURBINE TRIP WITHOUT BYPASS, WITH ICF, UNIT 2 (EOC 22)

FIGURE 15-22 DELETED IN REVISION 22.

FIGURE 15-23 DELETED IN REVISION 22.

FIGURE 15-24 CLOSURE OF ALL MSIV FLUX SCRAM, UNIT 1 - CURRENT CYCLE (CYCLE 21)

FIGURE 15-25 CLOSURE OF ALL MSIV FLUX SCRAM, UNIT 2 - (CYCLE 22)

FIGURE 15-26 EXTENDED POWER UPRATE MSIV CLOSURE WITH FLUX SCRAM (102 PERCENT INITIAL POWER)

FIGURE 15-27 UNIT 2 - CYCLE 1 LOSS OF AUXILIARY POWER (TRANSFORMER) WITH 25 PERCENT BYPASS FIGURE 15-28 UNIT 2 - CYCLE 1 LOSS OF AUXILIARY POWER (ALL GRID CONNECTIONS)

WITH 25 PERCENT BYPASS FIGURE 15-29 UNIT 1 - CYCLE 1 LOSS OF FEEDWATER FLOW FIGURE 15-30 UNIT 2 - CYCLE 1 LOSS OF FEEDWATER FLOW FIGURE 15-31 WATER LEVEL RESPONSE WITH REACTOR CORE ISOLATION COOLING FOR LOSS OF FEEDWATER FLOW EVENT AT ORIGINAL POWER

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Chapter:

15 Page:

2 of 2 LIST OF FIGURES FIGURE NUMBER TITLE FIGURE 15-32 PRESSURE RESPONSE WITH REACTOR CORE ISOLATION COOLING FOR LOSS OF FEEDWATER FLOW EVENT AT ORIGINAL POWER FIGURE 15-33 UNIT 2 - CYCLE 1 TRIP OF ONE RECIRCULATION PUMP FIGURE 15-34 UNIT 1 - CYCLE 1 TRIP OF TWO RECIRCULATION PUMPS FIGURE 15-35 UNIT 2 - CYCLE 1 TRIP OF BOTH RECIRCULATION PUMPS FIGURE 15-36 UNIT 1 - CYCLE 1 SEIZURE OF ONE RECIRCULATION PUMP FIGURE 15-37 UNIT 2 - CYCLE 1 SEIZURE OF ONE RECIRCULATION PUMP FIGURE 15-38 SEIZURE OF OPERATING RECIRCULATION PUMP SINGLE LOOP OPERATION FIGURE 15-39 UNIT 2 - CYCLE 1 ABNORMAL STARTUP OF IDLE RECIRCULATION PUMP FIGURE 15-40 UNIT 1 - CYCLE 1 ABNORMAL STARTUP OF IDLE RECIRCULATION PUMP FIGURE 15-41 UNIT 1 - CYCLE 1 RECIRCULATION FLOW CONTROL FAILURE - INCREASING FLOW FIGURE 15-42 UNIT 2 - CYCLE 1 RECIRCULATION FLOW CONTROL FAILURE - INCREASING FLOW FIGURE 15-43 UNIT 2 - CYCLE 1 MAXIMUM ROD WORTH VERSUS POWER LEVEL FIGURE 15-44 UNIT 2 - CYCLE 1 ROD DROP ACCIDENT (POWER RANGE) PEAK FUEL ENTHALPY FIGURE 15-45 MAIN STEAM LINE BREAK ACCIDENT BREAK LOCATION

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-1 Page:

1 of 1 PLANT SAFETY ANALYSIS METHOD FOR IDENTIFYING AND EVALUATING ABNORMAL OPERATIONAL TRANSIENTS

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-2 Page:

1 of 1 PLANT SAFETY ANALYSIS METHOD FOR IDENTIFYING AND EVALUATING ACCIDENTS

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-3 Page:

1 of 1 LOSS OF 100 DEGREE FEEDWATER HEATING, MANUAL FLOW CONTROL, UNIT 2 -CYCLE 7

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-5 Page:

1 of 1 FEEDWATER CONTROLLER FAILURE, MAXIMUM DEMAND (EOC), UNIT 1 - CYCLE 21

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-7 Page:

1 of 1 FEEDWATER CONTROLLER FAILURE, MAXIMUM DEMAND (EOC), UNIT 2 - CYCLE 22

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-10 Page:

1 of 1 FEEDWATER CONTROLLER FAILURE WITH TBPOOS, ICF, AND NFWT, UNIT 2 - CURRENT CYCLE (EOC 22)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-11 Page:

1 of 1 INADVERTENT HPCI ACTIVATION, UNIT 1 - CYCLE 9 (BOC9 TO EOC9)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-12 Page:

1 of 1 INADVERTENT HPCI ACTIVATION, UNIT 2 - CYCLE 10

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-13 Page:

1 of 1 PRESSURE REGULATOR FAILURE (OPEN), UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-14 Page:

1 of 1 PRESSURE REGULATOR FAILURE (OPEN), UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-15 Page:

1 of 1 INADVERTENT OPENING OF A RELIEF OR SAFETY VALVE, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-16 Page:

1 of 1 GENERATOR LOAD REJECTION WITH 25 PERCENT BYPASS, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-17 Page:

1 of 1 GENERATOR LOAD REJECTION, NO BYPASS, WITH ICF, UNIT 1 - CURRENT CYCLE (EOC 21)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-18 Page:

1 of 1 GENERATOR LOAD REJECTION, NO BYPASS, WITH ICF, UNIT 2 -CURRENT CYCLE (EOC 22)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-19 Page:

1 of 1 TURBINE TRIP WITH 25 PERCENT BYPASS, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-20 Page:

1 of 1 TURBINE TRIP WITHOUT BYPASS, WITH ICF, UNIT 1 - CURRENT CYCLE (EOC 21)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-21 Page:

1 of 1 TURBINE TRIP WITHOUT BYPASS, WITH ICF, UNIT 2 - CURRENT CYCLE (EOC 22)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-24 Page:

1 of 1 CLOSURE OF ALL MSIV, FLUX SCRAM, UNIT 1 - CURRENT CYCLE (CYCLE 21)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

25 Figure:

15-25 Page:

1 of 1 CLOSURE OF ALL MSIV, FLUX SCRAM, UNIT 2 -CYCLE 22

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-26 Page:

1 of 1 EXTENDED POWER UPRATE MSIV CLOSURE WITH FLUX SCRAM (102 PERCENT INITIAL POWER)

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-27 Page:

1 of 1 LOSS OF AUXILIARY POWER (TRANSFORMER) WITH 25 PERCENT BYPASS, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-28 Page:

1 of 1 LOSS OF AUXILIARY POWER (ALL GRID CONNECTIONS)

WITH 25 PERCENT BYPASS, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-29 Page:

1 of 1 LOSS OF FEEDWATER FLOW, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-30 Page:

1 of 1 LOSS OF FEEDWATER FLOW, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-31 Page:

1 of 1 WATER LEVEL RESPONSE WITH REACTOR CORE ISOLATION COOLING FOR LOSS OF FEEDWATER FLOW EVENT AT ORIGINAL POWER

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-32 Page:

1 of 1 PRESSURE RESPONSE WITH REACTOR CORE ISOLATION COOLING FOR LOSS OF FEEDWATER FLOW EVENT AT ORIGINAL POWER

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-33 Page:

1 of 1 TRIP OF ONE RECIRCULATION PUMP, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-34 Page:

1 of 1 TRIP OF BOTH RECIRCULATION PUMPS, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-35 Page:

1 of 1 TRIP OF BOTH RECIRCULATION PUMPS, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-36 Page:

1 of 1 SEIZURE OF ONE RECIRCULATION PUMP, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-37 Page:

1 of 1 SEIZURE OF ONE RECIRCULATION PUMP, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-38 Page:

1 of 1 SEIZURE OF OPERATING RECIRCULATION PUMP SINGLE LOOP OPERATION

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-39 Page:

1 of 1 ABNORMAL STARTUP OF IDLE RECIRCULATION PUMP, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-40 Page:

1 of 1 ABNORMAL STARTUP OF IDLE RECIRCULATION PUMP, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-41 Page:

1 of 1 RECIRCULATION FLOW CONTROL FAILURE - INCREASING FLOW, UNIT 1 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-42 Page:

1 of 1 RECIRCULATION FLOW CONTROL FAILURE - INCREASING FLOW, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-43 Page:

1 of 1 MAXIMUM ROD WORTH VERSUS POWER LEVEL, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-44 Page:

1 of 1 ROD DROP ACCIDENT (POWER RANGE) PEAK FUEL ENTHALPY, UNIT 2 - CYCLE 1

UPDATED FSAR ACCIDENT ANALYSES CHAPTER 15 FIGURES Revision:

24 Figure:

15-45 Page:

1 of 1 MAIN STEAM LINE BREAK ACCIDENT BREAK LOCATION