UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

25 Appendix :

7B Page:

1 of 1 LIST OF FIGURES FIGURE NUMBER TITLE 7B-1 TYPICAL TRIP UNIT/ CALIBRATION SYSTEM ELEMENTARY 7B-2 TYPICAL ECCS CONNECTION DIAGRAM 7B-3 MASTER TRIP UNIT FUNCTIONAL BLOCK DIAGRAM 7B-4 SAMPLE COMBINATION ARRANGEMENT OF MASTER AND SLAVE TRIP UNITS 7B-5 USE OF TRIP UNITS AS PARALLEL DRIVERS 7B-6 TRIP UNIT DRIVING PARALLEL RELAY COILS 7B-7 TYPICAL RPS CONNECTION DIAGRAM 7B-8 UNIT 2 - PRESSURE SWITCH TO ANALOG CHANGEOUT CONDUIT/TRAY AND CABLE ROUTING INTERCONNECTIONS TYPICAL FOR "ECCS" AND "RPS" SYSTEMS

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-1 Page:

1 of 1 TYPICAL TRIP UNIT/ CALIBRATION SYSTEM ELEMENTARY

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-2 Page:

1 of 1 TYPICAL ECCS CONNECTION DIAGRAM

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-3 Page:

1 of 1 MASTER TRIP UNIT FUNCTIONAL BLOCK DIAGRAM

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-4 Page:

1 of 1 SAMPLE COMBINATION ARRANGEMENT OF MASTER AND SLAVE TRIP UNITS

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-5 Page:

1 of 1 USE OF TRIP UNITS AS PARALLEL DRIVERS

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-6 Page:

1 of 1 TRIP UNIT DRIVING PARALLEL RELAY COILS

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-7 Page:

1 of 1 TYPICAL RPS CONNECTION DIAGRAM

UPDATED FSAR ANALOG CHANNELS FOR ENGINEERED SAFEGUARDS SENSOR TRIP INPUTS APPENDIX 7B FIGURES Revision:

24 Figure:

7B-8 Page:

1 of 1 UNIT 2 - PRESSURE SWITCH TO ANALOG CHANGEOUT CONDUIT/TRAY AND CABLE ROUTING INTERCONNECTIONS TYPICAL FOR "ECCS" AND "RPS" SYSTEMS