Category:Legal-Affidavit
MONTHYEARML20150E1772020-05-29029 May 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Extended Dhrs Operation and RCS Boron Redistribution (Closed Session), PM-0620-70243, Revision 0 ML20141L8082020-05-20020 May 2020 LLC Submittal of Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 3 ML20133K0882020-05-12012 May 2020 LLC, Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution (Closed Session), PM-0420-69512, Revision 0 RAIO-0420-69855, LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification2020-04-30030 April 2020 LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification ML20066H1812020-02-28028 February 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale FSAR Chapter 19 - Probabilistic Risk Assessment Area of Focus, PM-0220-69046, Revision 0 ML20066H1842020-02-28028 February 2020 LLC Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale FSAR Topic-Resolution of Chapter 15 Phase 2 Open Items (Closed Session), PM-0220-69063, Revision 0 ML20054A4112020-02-17017 February 2020 LLC - Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report - Loss-of-Coolant Accident Evaluation Model (Closed Session), PM-0220-68914, Revision 0 ML20054A9652020-02-17017 February 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report - Rod Ejection Accident Methodology (Closed Session), PM-1019-67366, Revision 0 ML20054A9692020-02-17017 February 2020 LLC Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topical Report- Non-Loss-of-Coolant Accident (Closed Session), PM-0220-68851, Revision 0 ML19353A7192019-12-19019 December 2019 LLC, Submittal of NuFuel-HTP2 Fuel and Control Rod Assembly Designs, TR-0816-51127, Revision 3 ML19352G6972019-12-18018 December 2019 LLC Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 2 ML19338E9482019-12-0404 December 2019 LLC Submittal of Human-System Interface Style Guide, ES-0304-1381, Revision 4 ML19337B4472019-12-0202 December 2019 LLC - Submittal of Changes to Long-Term Cooling Methodology, TR-0916-51299, Revision 1 ML19332A1202019-11-27027 November 2019 LLC Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19304B4712019-10-31031 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 466 (Erai No. 9482) on the NuScale Design Certification Application ML19238A3092019-08-26026 August 2019 LLC - Submittal Nuscale'S Proposed Closure Plan to Address Impacts of the Adjusted Iab Operations Range ML19238A3662019-08-23023 August 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19218A1472019-08-0505 August 2019 LLC - Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 1 ML19215A0062019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 441 (Erai No. 9485) on the NuScale Design Certification Application ML19215A0032019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19212A3752019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 483 (Erai No. 9516) on the NuScale Design Certification Application ML19212A7992019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19211D4112019-07-30030 July 2019 LLC Submittal of NuScale Power Module Short-Term Transient Analysis, TR-1016-51669, Revision 1 ML19207B3812019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19199A1172019-07-18018 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19192A1602019-07-0909 July 2019 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Evaluation Methodology for Stability Analysis of the NuScale Power Module, PM-0719-66244, Revision 0 ML19184A6152019-07-0303 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19183A4852019-07-0202 July 2019 LLC - Submittal of Fluence Calculation Methodology and Results, TR-0116-20781, Revision 1 ML19182A0462019-06-27027 June 2019 LLC - Submittal of Presentation Materials Titled TF-3 Modal Demonstration Testing and Siet Tour, PM-0619-66058-P, Revision 0 ML19176A5802019-06-25025 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19172A1012019-06-17017 June 2019 LLC - Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation, NuScale FSAR Chapter 15, Transient and Accident Analyses, and Chapter 6.2.1, Containment Functional Design, PM-0619-65992-P, Revision 0 ML19164A1452019-06-13013 June 2019 LLC - Submittal of Containment Response Analysis Methodology Technical Report, TR-0516 -49 08 4, Revision 1 ML19158A3822019-06-0707 June 2019 LLC - Submittal of Containment Vessel Ultimate Pressure Integrity, TR-0917-56119, Revision 1 ML19157A3262019-06-0606 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19154A6222019-06-0303 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19154A6052019-06-0303 June 2019 LLC Response to NRC Request for Additional Information No. 514 (Erai No. 9645) on the NuScale Design Certification Application ML19151A8102019-05-31031 May 2019 LLC Submittal of Technical Report NuScale Generic Technical Guidelines, TR-1117-57216, Revision 1 ML19151A8372019-05-31031 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 377 (Erai No. 9380) on the NuScale Design Certification Application ML19151A8342019-05-31031 May 2019 LLC - Submittal of Turbine Missile Barrier Design Closure Plan Actions (Final Safety Analysis Report, Tier 2, Section 3.5.1.3) ML19149A2982019-05-28028 May 2019 LLC Submittal of NuScale Containment Leakage Integrity Assurance, TR-1116-51962, Revision 1 ML19137A3612019-05-17017 May 2019 LLC - Submittal of Nuclear Steam Supply System Advanced Sensor Technical Report, TR-0316-22048, Revision 2 ML19119A3982019-04-29029 April 2019 LLC - Submittal of Human-System Interface Design Results Summary Report, RP-0316-17619, Revision 2 ML19119A3422019-04-29029 April 2019 LLC Submittal of Human Factors Engineering Program Management Plan, RP-0914-8534, Revision 5 ML19119A3932019-04-29029 April 2019 LLC - Submittal of Human Factors Engineering Task Analysis Results Summary Report, RP-0316-17616 Revision 2. (Non-Proprietary Version) ML19105B0772019-04-15015 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 478 (Erai No. 9470) on the NuScale Design Certification Application ML19101A4412019-04-11011 April 2019 LLC Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19099A4732019-04-0909 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19098B6202019-04-0808 April 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 465 (Erai No. 9494) on the NuScale Design Certification Application ML19093B8502019-04-0303 April 2019 LLC - Submittal of Technical Report TR-0916-51502, NuScale Power Module Seismic Analysis, Revision 2 ML19087A2882019-03-28028 March 2019 LLC Updates to Final Safety Analysis Report, Section 1.6,Materials Referenced, Section 3.6, Protection Against Dynamic Effects Associated with Postulated Rupture of Piping, and the Pipe Rupture Hazards Analysis, TR-0818-61384 2020-05-29
[Table view] Category:Letter
MONTHYEARML23234A1232024-03-28028 March 2024 US600 DC and SDA 50.46 Exemption - Letter ML23180A1512023-06-29029 June 2023 LLC, Request for Exemption to the Reporting Requirements of 10 CFR 50.46(a)(3) ML21102A3072021-04-15015 April 2021 OEDO-21-00155 - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC, Small Modular Reactor ML21050A4312021-02-19019 February 2021 LLC - Lessons-Learned from the Design Certification Review of the NuScale Power, LLC Small Modular Reactor ML20247J5642020-09-11011 September 2020 Standard Design Approval for the NuScale Power Plant Based on the NuScale 600 Standard Plant Design Certification Application ML20231A8042020-08-28028 August 2020 Final Safety Evaluation Report for the NuScale Standard Plant Design ML20224A4602020-08-25025 August 2020 OEDO-20-00292-Response to the Advisory Committee on Reactor Safeguards Letter on NuScale Power, LLC, Report on the Safety Aspects of the NuScale Small Modular Reactor ML20231A5982020-08-25025 August 2020 OEDO-20-00285_NuScale Area of Focus - Boron Redistribution ML20210M8902020-07-29029 July 2020 Area of Focus - Boron Redistribution ML20195A5872020-07-13013 July 2020 LLC - Submittal of Draft Operator Licensing and Examination Standard for NuScale Small Modular Reactors ML20195C7662020-07-13013 July 2020 LLC Request for Standard Design Approval Based on the NuScale Standard Plant Design Certification Application ML20192A3262020-07-10010 July 2020 LLC, Submittal of Environmental Report: Revision Status ML20198M3932020-07-0202 July 2020 LLC Submittal of Revised Packing Slip for Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1, Dated June 19, 2020 ML20174A3472020-07-0101 July 2020 OEDO-20-00220 - Area of Focus - Probabilistic Risk Assessment and Emergency Core Cooling System Valve Performance ML20184A2872020-07-0101 July 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and General Design Criterion 33, PM-0720-70785, Revision 0 ML20181A2702020-06-22022 June 2020 Final SER for NuScale TR-0516-49422 Loss-of-Coolant Analysis Model, Rev 2 (Letter) ML20181A4322020-06-22022 June 2020 Final SER for NuScale TR-0516-49416 NON-Loss-of-Coolant Analysis Model, Rev 3 (Letter) ML20198M3922020-06-19019 June 2020 LLC - Submittal of the NuScale Standard Plant Design Certification Application, Revision 4.1 ML20171A7312020-06-19019 June 2020 LLC, Submittal of Riser Flow Hole Methodology and Associated Changes to Final Safety Analysis Report Incorporating Its Use ML20157A2232020-06-0303 June 2020 Letter to NuScale Requesting -A for TR-0716-50350 ML20150C5172020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled NRC Public Meeting Presentation: Boron Redistribution and Associated Design and DCA Changes, PM-0620-70336, Revision 0 ML20150E1772020-05-29029 May 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Extended Dhrs Operation and RCS Boron Redistribution (Closed Session), PM-0620-70243, Revision 0 ML20150C8812020-05-29029 May 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topic - Boron Redistribution and Associated Design and DCA Changes, PM-0620-70244, Revision 0 ML20149M1192020-05-28028 May 2020 LLC Summary of Impacts to Erai 8930 Response and Discussion on the Exemption from General Design Criterion 33 ML20141L8082020-05-20020 May 2020 LLC Submittal of Containment Response Analysis Methodology Technical Report, TR-0516-49084, Revision 3 ML20141N0122020-05-20020 May 2020 LLC Submittal of Changes to Final Safety Analysis Report, Section 6.2, Containment Systems, Section 6.3, Emergency Core Cooling System, and Technical Report TR-0516-49084, Containment Response Analysis Methodology Technical Report ML20141L8162020-05-20020 May 2020 LLC, Submittal of Long-Term Cooling Methodology, TR-0916-51299, Revision 3 ML20141M7642020-05-20020 May 2020 LLC Submittal of Nuclear Steam Supply System Advanced Sensor Technical Report, TR-0316-22048, Revision 3 ML20141L7872020-05-20020 May 2020 LLC, Submittal of Second Updates to Standard Plant Design Certification Application, Revision 4 ML20141M1142020-05-20020 May 2020 LLC Submittal of NuScale Instrument Setpoint Methodology Technical Report, TR-0616-49121, Revision 3 ML20141L8042020-05-20020 May 2020 LLC Submittal of Technical Specifications Regulatory Conformance and Development, TR-1116-52011, Revision 4 ML20128J3162020-05-18018 May 2020 OEDO-20-00167 - Response to the ACRS Letter on Combustible Gas Monitoring ML20133K0882020-05-12012 May 2020 LLC, Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution (Closed Session), PM-0420-69512, Revision 0 ML20133J9142020-05-11011 May 2020 LLC Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0420-69511, Revision 0 ML20112F4552020-05-0101 May 2020 LLC, Design Certification Application Phases 5 and 6 Review Status ML20107F8492020-05-0101 May 2020 OEDO-2000140 - NuScale Area of Focus - Helical Tube Steam Generator Design ML20104A0792020-04-27027 April 2020 OEDO-20-00115 - Safety Evaluation Report for Topical Report TR-0516-49416, Revision 2, Non-Loss-of-Coolant Accident Analysis Methodology ML20099H0802020-04-0808 April 2020 LLC - Submittal of Presentation Materials Entitled NRC Public Meeting: Revisions to Nuscale'S EPZ Sizing Methodology Topical Report, PM-0420-69598, Revision 0 ML20098G2372020-04-0707 April 2020 Nuscale Power, LLC Submittal of Remaining Closure Items for the Emergency Core Cooling System Valve Failure Mode Effects Analysis Audit Items ML20097F1922020-04-0606 April 2020 Nuscale Power, LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: Nuscale Topic - Hydrogen/Oxygen Monitoring, PM-0420-69518, Revision 0 ML20094H6742020-04-0303 April 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation NuScale Topic-Probabilistic Risk Assessment with a Focus on Emergency Core Cooling System Analysis PM-0420-69559, Revision 0 ML20092L8992020-04-0101 April 2020 LLC - Submittal of Updates to Standard Plant Design Certification Application, Revision 4 ML20072M6682020-03-30030 March 2020 Response to NuScale Letter Dated February 24, 2020, on Planned SDA Application Content ML20072H3332020-03-0909 March 2020 LLC - Submittal of Presentation Materials Entitled Public Meeting Presentation: Topic - Emergency Core Cooling System (ECCS) Boron Distribution, PM-0320-69218, Revision 0 ML20057D9002020-03-0606 March 2020 Submittal of Errata to Final SE for NuScale Power, LLC TR-1010-859-NP-A, Quality Assurance Program Description for the NuScale Power Plant ML20062F7262020-03-0505 March 2020 Request for Withholding Information from Public Disclosure for Nuscale Power, LLC Letter Public ML20069A9632020-03-0404 March 2020 LLC Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report, Loss-of-Coolant Accident Evaluation Model, PM-0320-69138, Revision 0 ML20069A1772020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Non-Loss-of-Coolant Accident, PM-0320-69141, Revision 0 ML20069A1572020-03-0404 March 2020 LLC - Submittal of Presentation Materials Entitled ACRS Full Committee Presentation: NuScale Topical Report-Rod Ejection Accident Methodology, PM-0320-69146, Revision 0 ML20066G2802020-03-0303 March 2020 LLC, Submittal of Presentation Materials Entitled ACRS Subcommittee Presentation: NuScale Topic - Hydrogen Monitoring, PM-0220-69071, Revision 0 2024-03-28
[Table view] Category:Response to Request for Additional Information (RAI)
MONTHYEARRAIO-0420-69855, LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification2020-04-30030 April 2020 LLC, Submittal of Corrected Response to NRC Request for Additional Information No. 284 (Erai No. 9225) on the NuScale Design Certification ML19332A1202019-11-27027 November 2019 LLC Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19304B4712019-10-31031 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 466 (Erai No. 9482) on the NuScale Design Certification Application ML19296D8052019-10-23023 October 2019 LLC Response to NRC Request for Additional Information No. 526 (Erai No. 9719) on the NuScale Design Certification Application ML19283E5302019-10-10010 October 2019 LLC Supplemental Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19260G7352019-10-0707 October 2019 Summary of Public Meeting with NuScale to Discuss Response to RAI 9681 ML19266A5872019-09-23023 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 518 (Erai No. 9659) on the NuScale Design Certification Application ML19262G9742019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Tier 1, Section 3.11, Reactor Building and Section 3.13, Control Building, and Tier 2, Section 3.8.4, Design of Category I Structure and Section 14.3, Certified ... ML19262G5762019-09-19019 September 2019 LLC - Submittal of Changes to Final Safety Analysis Report, Section 14.2, Initial Plant Test Program, Table 14.2-2, Pool Cleanup Systems Test #2, and Table 14.2-50, Module Assembly Equipment Test #50 ML19259B8102019-09-16016 September 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19259A0922019-09-16016 September 2019 LLC Response to NRC Request for Additional Information No. 525 (Erai No. 9705) on the NuScale Design Certification Application ML19238A3722019-08-26026 August 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19238A3662019-08-23023 August 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19215A0032019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19215A0062019-08-0202 August 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 441 (Erai No. 9485) on the NuScale Design Certification Application ML19212A7622019-07-31031 July 2019 LLC Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19212A3752019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 483 (Erai No. 9516) on the NuScale Design Certification Application ML19212A7992019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19212A6892019-07-31031 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 205 (Erai No. 9044) on the NuScale Design Certification Application ML19210D1592019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19210D7342019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 520 (Erai No. 9642) on the NuScale Design Certification Application ML19210E1462019-07-29029 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19207B3812019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 427 (Erai No. 9408) on the NuScale Design Certification Application ML19207A5342019-07-26026 July 2019 LLC - Response to NRC Request for Additional Information No. 523 (Erai No. 9682) on the NuScale Design Certification Application ML19207B8522019-07-25025 July 2019 LLC Response to NRC Request for Additional Information No. 194 (Erai No. 8884) on the NuScale Design Certification Application ML19203A3152019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19203A3212019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 333 (Erai No. 9282) on the NuScale Design Certification Application ML19203A3092019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 54 (Erai No. 8837) on the NuScale Design Certification Application ML19203A3422019-07-22022 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 154 (Erai No. 8938) on the NuScale Design Certification Application ML19200A2482019-07-19019 July 2019 LLC Response to NRC Request for Additional Information No. 522 (Erai No. 9681) on the NuScale Design Certification Application ML19200A2082019-07-19019 July 2019 LLC - Response to NRC Request for Additional Information No. 524 (Erai No. 9691) on the NuScale Design Certification Application ML19199A1172019-07-18018 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 484 (Erai No. 8930) on the NuScale Design Certification Application ML19198A3252019-07-17017 July 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 249 (Erai No. 9135) on the NuScale Design Certification Application ML19196A3682019-07-15015 July 2019 LLC Response to NRC Request for Additional Information No. 516 (Erai No. 9647) on the NuScale Design Certification Application ML19191A2202019-07-10010 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 197 (Erai No. 9051) on the NuScale Design Certification Application ML19184A6152019-07-0303 July 2019 LLC Supplemental Response to NRC Request for Additional Information No. 386 (Erai No. 9316) on the NuScale Design Certification Application ML19176A5802019-06-25025 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19170A3702019-06-19019 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19168A2442019-06-17017 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 325 (Erai No. 9268) on the NuScale Design Certification Application ML19164A1452019-06-13013 June 2019 LLC - Submittal of Containment Response Analysis Methodology Technical Report, TR-0516 -49 08 4, Revision 1 ML19157A3262019-06-0606 June 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 232 (Erai No. 9113) on the NuScale Design Certification Application ML19154A6222019-06-0303 June 2019 LLC Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on the NuScale Design Certification Application ML19154A6052019-06-0303 June 2019 LLC Response to NRC Request for Additional Information No. 514 (Erai No. 9645) on the NuScale Design Certification Application ML19151A8372019-05-31031 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 377 (Erai No. 9380) on the NuScale Design Certification Application ML19140A4592019-05-20020 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 401 (Erai No. 9447) on the NuScale Design Certification Application ML19137A2902019-05-17017 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 156 (Erai No. 9031) on the NuScale Design Certification Application ML19137A2872019-05-15015 May 2019 LLC Response to NRC Request for Additional Information No. 519 (Erai No. 9656) on the NuScale Design Certification Application ML19126A2942019-05-0606 May 2019 LLC Supplemental Response to NRC Request for Additional Information No. 26 (Erai No. 8840) on the NuScale Design Certification Application ML19122A5092019-05-0202 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 494 (Erai No. 9548)on the Design Certification Application ML19121A6002019-05-0101 May 2019 LLC - Supplemental Response to NRC Request for Additional Information No. 202 (Erai No. 8911) on Design Certification Application 2020-04-30
[Table view] |
Text
RAIO-0718-60971 July 20, 2018 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Response to NRC Request for Additional Information No.
481 (eRAI No. 9368) on the NuScale Design Certification Application
REFERENCE:
U.S. Nuclear Regulatory Commission, "Request for Additional Information No.
481 (eRAI No. 9368)," dated May 21, 2018 The purpose of this letter is to provide the NuScale Power, LLC (NuScale) response to the referenced NRC Request for Additional Information (RAI).
The Enclosures to this letter contain NuScale's response to the following RAI Question from NRC eRAI No. 9368:
15.06.03-4 is the proprietary version of the NuScale Response to NRC RAI No. 481 (eRAI No.
9368). NuScale requests that the proprietary version be withheld from public disclosure in accordance with the requirements of 10 CFR § 2.390. The enclosed affidavit (Enclosure 3) supports this request. Enclosure 2 is the nonproprietary version of the NuScale response.
This letter and the enclosed responses make no new regulatory commitments and no revisions to any existing regulatory commitments.
If you have any questions on this response, please contact Paul Infanger at 541-452-7351 or at pinfanger@nuscalepower.com.
Sincerely, Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Gregory Cranston, NRC, OWFN-8G9A Samuel Lee, NRC, OWFN-8G9A Rani Franovich, NRC, OWFN-8G9A NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0718-60971 : NuScale Response to NRC Request for Additional Information eRAI No. 9368, proprietary : NuScale Response to NRC Request for Additional Information eRAI No. 9368,
nonproprietary : Affidavit of Zackary W. Rad, AF-0718-60972 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0718-60971 :
NuScale Response to NRC Request for Additional Information eRAI No. 9368, proprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
RAIO-0718-60971 :
NuScale Response to NRC Request for Additional Information eRAI No. 9368, nonproprietary NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
Response to Request for Additional Information Docket No.52-048 eRAI No.: 9368 Date of RAI Issue: 05/21/2018 NRC Question No.: 15.06.03-4 Title 10 of the Code of Federal Regulations (10 CFR) 52.47(a)(2)(iv) requires that an application for a design certification include a final safety analysis report (FSAR) that provides a description and safety assessment of the facility. The safety assessment analyses are done, in part, to show compliance with the radiological consequence evaluation factors in 52.47(a)(2)(iv)(A) and 52.47(a)(2)(iv)(B) for offsite doses; and 10 CFR Part 50, Appendix A, General Design Criterion (GDC) 19 for control room radiological habitability.
The radiological consequences of design basis accidents are evaluated against these regulatory requirements and the dose acceptance criteria given in Standard Review Plan (SRP) Section 15.0.3. NRC staff needs to ensure that a suitably conservative estimate is determined for the radiological release associated with the steam generator tube rupture event (SGTR). In addition, 10 CFR Part 50, Appendix A, General Design Criterion (GDC) 54, Piping systems penetrating containment, requires piping systems penetrating primary reactor containment to be provided with leak detection, isolation, and containment capabilities having redundancy, reliability, and performance capabilities that reflect the importance to safety of isolating these piping systems.
Steam generator (SG) overfilling is a major concern for an SGTR related to the potential loss of secondary side integrity and extended radioactivity releases to the atmosphere. As a result of the 1982 SGTR event at the Ginna Plant, the NRC questioned equipment capability and assumptions used in FSAR analyses and issued Generic Letter 89-19.
As indicated by the applicant in FSAR Tier 2, Section 15.6.3.1, [t]he design of the helical coil steam generators (HCSGs), described in Section 5.4, is different from the design of SGs in conventional pressurized water reactors [PWRs] because primary coolant is located on the outside, or shell side, of the tubes. In addition, the staff notes that the inventory of the SGs is also very small, so the radiological consequences of a SGTR could be more severe than for conventional PWRs. The mitigation of the SGTR event is dependent upon closure of the main steam isolation valve (MSIV) or the secondary MSIV, depending on the single active failure assumed.
It is not clear to the staff that NuScale's submitted limiting case sequence of events and assumptions would maximize the RCS mass release prior to the secondary main steam isolation valve closing. The maximum RCS mass release affects the input to the dose analysis NuScale Nonproprietary
and establishes potentially the worst conditions (e.g., quality) in which the MSIV and secondary MSIV are required to close. In response to RAI 8794 the applicant indicated that the MSIV and secondary MSIV are designed to close in steam and liquid conditions but did not provide sufficient detail and justification for the staff to make a regulatory finding.
Therefore, the applicant is requested to provide additional information justifying that a conservative RCS mass release prior to the closure of secondary MSIV is calculated, including uncertainties in friction and form losses in the tubes, inlet orifices and tube sheet, and that the MSIV and secondary MSIV will close under the worst expected steam generator failure conditions.
NuScale Response:
The secondary integrity issue identified in Generic Letter 89-19 does not apply to the NuScale design because, unlike traditional PWRs, the secondary design pressure, between the feedwater regulating valves and the backup secondary isolation valves is rated to the same pressure as the reactor pressure vessel (RPV). Therefore, after secondary isolation, the shell and tube side of the steam generator can fully equalize in pressure without challenging the secondary design pressure. For this event, small secondary volume of the NuScale design is a beneficial design feature because it allows for rapid pressure equalization between the primary and secondary which mitigates the overall inventory loss. In addition both the reactor safety valves and steam generator thermal relief valves are located inside containment so over pressurization actuation of either of these would not lead to atmospheric releases. Therefore the steam generator tube failure event for the NuScale design is much less severe than a typical PWR which is evidenced in the simplicity of event mitigation safety features and low overall dose consequences (approximately 450 percent margin to control room dose limits) as presented in FSAR Table 15.0-12.
The break model methodology applied for the steam generator tube failure event applies the
((2(a),(c) The methodology applied to identify the limiting steam generator tube failure scenario for radiological consequence presented in the FSAR is consistent with the Non-Loss of Coolant Accident Analysis Methodology topical report (TR-0516-49416-P, Rev. 0).
In the radiological analysis of the event, all the mass that flows through the failed tube is assumed to be released to the environment. Therefore, changes to the hydraulic resistances on the secondary side would not impact the maximum overall mass release.
NuScale Nonproprietary
For the NuScale design, the following considerations are key to achieving a maximal break mass release:
- 1. Maximal drop in pressurizer level before isolation provides a primary indication of maximal mass release. To maximize mass release, the pressurizer level is biased high and drops as low as possible before isolation. Isolation can occur in response to a low-low pressurizer level signal, but in practice the expansion of the vapor space due to drop in level causes secondary isolation on low pressurizer pressure signal (1600 psia) to occur before the low-low pressurizer level signal (<20%) is reached because the reactor and pressurizer heaters are tripped at low pressurizer level (<35%). Thus a low pressurizer pressure signal is indicative of reaching the lowest level in the pressurizer possible before isolation. The sensitivities verified that the limiting signal for maximal mass release is a low pressurizer pressure signal.
- 2. Heating of the RPV liquid after transient initiation increases mass release. This is primarily due to the fact that heating causes RPV liquid expansion and delays actuation of the low pressurizer level signal while cooling the liquid contracts the liquid and causes actuation sooner. For this reason, beginning of cycle reactor kinetics increased mass release since the reactivity insertion caused additional heating of the RPV liquid and delayed the low pressurizer level signal.
- 3. High density at the break is limiting. An RPV temperature that is biased low leads to a higher density at the break. The higher density break flow results in less decrease in level per mass ejected from the break, and sensitivities confirmed this to be limiting.
- 4. Break flow rate is important after reactor trip, but maximal break flow is not necessarily limiting. Reactor trip occurs in response to a low pressurizer level signal.
After reactor trip, the RPV liquid starts to cool and level drops in the pressurizer due to density changes. At this point a competing condition is established where level will drop due to cooling and due to break flow. Thus a maximal break flow is limiting unless there is an impact on the RPV liquid heat transfer that leads to earlier isolation. The sensitivities verified that the largest break flow is not limiting. For example, breaks located at the bottom of the SG tube had a higher break flow than breaks located at the top of the steam generator tube. Despite the higher break flow, the breaks at the bottom of the steam generator tube were not limiting because flow into the steam generator tube sheet enhanced the heat transfer from the RPV to the steam generator and caused the pressurizer level to drop more rapidly leading to an earlier reactor trip on low pressurizer level followed by a low pressurizer pressure trip signal for secondary isolation.
The sensitivities performed verified that these are the primary factors that influence mass release. The sensitivity included the system parameters that have an important impact on drop in pressurizer level, RPV liquid heating after transient intitiation, density at the break, and break flow rate. Break location and break size are primary factors that influence break flow rate and were included in the sensitivities to ensure a limiting break flow rate for maximal mass release was achieved in the analysis.
NuScale Nonproprietary
As described in the supplemental response to eRAI 8794, Question 15.06.03-2 (Letter RAIO-0618-60721 submitted on June 29, 2018) the secondary isolation valves are qualified based on the events that generate the maximum forces, based on differential pressure across the valve, under which the valve actuators must be designed to ensure closure of the valve. In the case of both the feedwater isolation valves (FWIVs) and MSIVs, this is determined to be the secondary pipe break accidents where the actuators are required to close the valve under the force of fully developed pipe break flowrates. Regardless of the actual steam quality conditions for the steam generator tube failure event, the flow through the MSIV and the differential pressure across the valve is close to normal operating conditions. Therefore, it is determined the steam generator tube failure event is well bounded by the existing qualification requirements of the MSIV.
In summary, the small secondary volume and high design pressure of the secondary system is an asset for the NuScale design by allowing full pressure equalization between the primary and avoiding the need for the actuation of a lower pressure main steam safety relief valve which is problematic for traditional PWRs. The existing steam generator tube failure sensitivity cases are sufficient to identify the optimal break flowrate to maximize the mass release and dose consequences. Finally, the qualification of the MSIVs is sufficient to ensure the valves will close under all possible steam generator tube failure conditions.
Impact on DCA:
There are no impacts to the DCA as a result of this response.
NuScale Nonproprietary
RAIO-0718-60971 :
Affidavit of Zackary W. Rad, AF-0718-60972 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
NuScale Power, LLC AFFIDAVIT of Zackary W. Rad I, Zackary W. Rad, state as follows:
- 1. I am the Director, Regulatory Affairs of NuScale Power, LLC (NuScale), and as such, I have been specifically delegated the function of reviewing the information described in this Affidavit that NuScale seeks to have withheld from public disclosure, and am authorized to apply for its withholding on behalf of NuScale.
- 2. I am knowledgeable of the criteria and procedures used by NuScale in designating information as a trade secret, privileged, or as confidential commercial or financial information. This request to withhold information from public disclosure is driven by one or more of the following:
- a. The information requested to be withheld reveals distinguishing aspects of a process (or component, structure, tool, method, etc.) whose use by NuScale competitors, without a license from NuScale, would constitute a competitive economic disadvantage to NuScale.
- b. The information requested to be withheld consists of supporting data, including test data, relative to a process (or component, structure, tool, method, etc.), and the application of the data secures a competitive economic advantage, as described more fully in paragraph 3 of this Affidavit.
- c. Use by a competitor of the information requested to be withheld would reduce the competitor's expenditure of resources, or improve its competitive position, in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.
- d. The information requested to be withheld reveals cost or price information, production capabilities, budget levels, or commercial strategies of NuScale.
- e. The information requested to be withheld consists of patentable ideas.
- 3. Public disclosure of the information sought to be withheld is likely to cause substantial harm to NuScale's competitive position and foreclose or reduce the availability of profit-making opportunities. The accompanying Request for Additional Information response reveals distinguishing aspects about the process and method by which NuScale develops its safety analysis of the NuScale Power Module.
NuScale has performed significant research and evaluation to develop a basis for this process and method and has invested significant resources, including the expenditure of a considerable sum of money.
The precise financial value of the information is difficult to quantify, but it is a key element of the design basis for a NuScale plant and, therefore, has substantial value to NuScale.
If the information were disclosed to the public, NuScale's competitors would have access to the information without purchasing the right to use it or having been required to undertake a similar expenditure of resources. Such disclosure would constitute a misappropriation of NuScale's intellectual property, and would deprive NuScale of the opportunity to exercise its competitive advantage to seek an adequate return on its investment.
AF-0718-60972
- 4. The information sought to be withheld is in the enclosed response to NRC Request for Additional Information No. 481, eRAI No. 9368. The enclosure contains the designation "Proprietary" at the top of each page containing proprietary information. The information considered by NuScale to be proprietary is identified within double braces, "(( }}" in the document.
- 5. The basis for proposing that the information be withheld is that NuScale treats the information as a trade secret, privileged, or as confidential commercial or financial information. NuScale relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC § 552(b)(4), as well as exemptions applicable to the NRC under 10 CFR §§ 2.390(a)(4) and 9.17(a)(4).
- 6. Pursuant to the provisions set forth in 10 CFR § 2.390(b)(4), the following is provided for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld:
- a. The information sought to be withheld is owned and has been held in confidence by NuScale.
- b. The information is of a sort customarily held in confidence by NuScale and, to the best of my knowledge and belief, consistently has been held in confidence by NuScale.
The procedure for approval of external release of such information typically requires review by the staff manager, project manager, chief technology officer or other equivalent authority, or the manager of the cognizant marketing function (or his delegate), for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside NuScale are limited to regulatory bodies, customers and potential customers and their agents, suppliers, licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or contractual agreements to maintain confidentiality.
- c. The information is being transmitted to and received by the NRC in confidence.
- d. No public disclosure of the information has been made, and it is not available in public sources. All disclosures to third parties, including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or contractual agreements that provide for maintenance of the information in confidence.
- e. Public disclosure of the information is likely to cause substantial harm to the competitive position of NuScale, taking into account the value of the information to NuScale, the amount of effort and money expended by NuScale in developing the information, and the difficulty others would have in acquiring or duplicating the information. The information sought to be withheld is part of NuScale's technology that provides NuScale with a competitive advantage over other firms in the industry.
NuScale has invested significant human and financial capital in developing this technology and NuScale believes it would be difficult for others to duplicate the technology without access to the information sought to be withheld.
I declare under penalty of perjury that the foregoing is true and correct. Executed on July 20, 2018.
Zackary W. Rad AF-0718-60972}}