ML18142A113

From kanterella
Jump to navigation Jump to search
Acceptance Test Procedure ATP446, JC177-Q2 Jumper Card
ML18142A113
Person / Time
Site: Surry, 05000000
Issue date: 04/09/1981
From: Kamerman L
VALIDYNE ENGINEERING SALES CORP.
To:
Shared Package
ML18130A405 List:
References
ATP446, NUDOCS 8411200444
Download: ML18142A113 (10)


Text

REVISIONS LTR ECO DESCRIPTION DATE APPROVED

(--8411200444 841105_

\\

PDR AD0CK 05000280_

F.

PDR SIGNATURE **,,,

\\

I DATE TITLE PROD TEST

.../ /., !,,,1 JCl 77-Q.2 Jumper Card

.: ; i '"

  • Acceptance Test Procedure 1...E...;.NG_I_NE_E_RI_NG __ 4-+~~::::::::1'-LJ..J~----~-4-~--I NUMBER QUAL CONTROL ATP446 SHEET 1

DF 3

8626.WILBUR AVENUE

  • NORTHRIDGE. CA 91324 * (213) 886-8488
  • Telex No. 65*1303 VEC 304-1,,ao REV

L AlidyNE l!NGIN*&IIING COIIPOIIATION i.o SCOPE This document defines the Acceptance Test Procedure (ATP) for the JCl 77-Q2 Circuit Board Assembly.

A sample of th_e test report. to be used with this ATP is contained in Appendix A.

2.0 EQUIPMENT REQUIRED Table 1 lists the test equipment required to perform the ATP.

Table 1 - Equipment Required for ATP Part No.

Description Manufacturer or Model Alternate Digital Multimeter Data Precision PROCEDURE 245 Commercial Equivalent Refer to Drawing No. Ql0206 and visually inspect the unit for completeness and accuracy.

3.2 Set DMM to kOhm measurement mode and range to 1 k Ohm.

3.3 Connect the DMM leads together and record the reading Rs Ohms.

3.4 Connect the DMM leads to edge connection pins 20 and 26.

The DMM reading should be the same as in step 3.3 +/-0.1 Ohm.

Indicate acceptance on test report with checkmark.

3.5 Connect the DMM leads to edge connector pins 20 and test point TPl.

The DMM reading should be the same as in step 3.3 +/-0.1 Ohm.

Indicate acceptance on test report with checkmark.

3.6 Connect DMM leads to edge connection pins 22 and 24 instead of 20 and TPl.

The DMM reading should be the same as in step 3.3 +/-0.1 Ohm.

Indicate acceptance on test report with checkmark.

3.7 Disconnect DMM leads from the unit.

NUMBER AT1'446 SHEET 2

OF 8626 WILBUR AVENUE

  • NORTH RIDGE. CA 91324. * (213) 886-8488
  • Telex No. 65*1303 3

REV

VEr ins; 111Rn AlidyNE ENGINEEIIIND COllll'OIIAT10N APPENDIX A SAMPLE TEST REPORT NUMBER ATP446 SHEET 3

OF 8626 WILBUR AVENUE* NORTHRIDGE. CA 91324 * (213}886-8488

  • Tele>< No. 65-1303 REV 3

(

A idyNE TEST REPORT S/0 W/0 TESTED BY ENOINl!l!IIINQ COIIPOIIATION ASSY JC177-Q2 Jumper Card Circuit Board Assembly CUSTOMER SERIAL NO.

DATE Paragraph/Step Accepted 3.3 Rs 3.4 Resistance between 20 & 26 3.5 Resistance between 20 & TPl 3.6 Resistance between 22 & 24 oc Ohms NUMBER ATP446 SHEET 1

Specification

  • Rs+/-O. 1 Ohms Rs+/-D.1.0hms REV OF 1

8626 WILBUR AVENUE

  • NORTHRIDGE. CA 91324 * (213) 886-8488
  • Tele,c No. 65-1303 VEC 306.

1

AlidyNE ENGINl!l!IHNG COlll'OIIA'ffON REVISIONS LTR ECO DESCRIPTION

. DATE APPROVED SIGNATURE TITLE

...J..~,.

/.

i-------------~-------+---.----1 PS324-Q2 Remote 24VDC Power Su pp ly PROD TEST

/~*

  • .(y;*.~.,-_;.. _/ _

~,*, '

Acceptance Test Procedure

~EN_GI_NE_E_RIN_G_---1......:;;,;........-~-----4-'~--6.:.../8'_, _; _*-1 NUMBER QUAL CONTROL REV ATP455 SHEET l

OF 4

8626 WILBUR AVENUE

  • NORTHAIDGE. CA 91324 * (213) 886-8488
  • Telex No. 65-1303 VEC 304-11/80 L

(

AlidyNE l!NGINaa,11-COIIPO-TION 1.0 SCOPE This document defines the Acceptance Test Procedure (ATP) for PS324-Q2 power supply assembly.

Either the end item ATP or a special test procedure appropriate to a particular contract will define any additional require-ments.

A sample test report is included in Appendix A.

2.0 EQUIPMENT REQUIRED Table 1 lists the test equipment required.to perform the ATP.

Table l - E ui ment Required for ATP Part No.

Description Manufacturer or Model Variac 2 Digital Multimeters PS324 Tester 3 Conductor line cord with spade terminals 3~0 PRELIMINARY PROCEDURE Superior Electric Co Data Precision Validyne 11 SV AC 116 DP248 Tl098 Alternate Commercial Equivalen Commercial Equivalen None Refer to assembly drawing number PS324-Q2 and visually inspect for complete-ness and accuracy.

Make sure the fuse rating is lA.

4. 0.INITIAL TEST SET -UP 4.1 Connect PS324-Q2, Digital Multimeters (DMM), variac & PS324 tester as shown in figure 1. Set the variac to lowest dial setting. Make sure load ON/OFF switch.on tester is on OFF position.

4.2 Plug in variac to 115V AC & switch it ON.

Slowly increase the*variac out-put to 115V AC.

The power on green light emitting diode (LED) on PS324-Q2 should be on.

NUMBER ATP455 SHEET 2

OF 4

8626 WILBUR AVENUE

  • NORTH RIDGE. CA 91324 * (2131 886-8488 e Telex No. 65-1303

.REV

(

VAi?.IA C.

IS"V AC I

I l'.;!°".,\\"r G.Rt:ftJ IN Ii IT!:

~!..""

/15"vAC.

!;llf,VD(

'"r-6 Hr

+u r5-)

f--0 LO t2i- - 0

-c G.r,IJ)

~Nl)L.'

f /CiW<E

1.

f 9 A(idyNE l!NQINEa,11-COIIPOIIATION

.I>MM

  • FDI<...

Ac..

Of=

0 HI COM C: :r--_ 3 Wli?.i.

L1r,11i. co'2I:>.

+

f.S.324--Ex.1.

J)f"lM "Tes.rel.

..:)

~Nl)

Co,.\\

,-,r 0

0 NUMBER ATP455 SHEET 3

OF 8626 WIL:BUR AVENUE

  • NORTHRIDGE. CA 91324 * (213) 886-8488
  • Telex No. 65-1303 REV 4

AlidyNE l!NGINBIIIII-COllll'OIIATION 5.0 FUNCTIONAL TESTS

5. l Load Regulation
5. 1. l With load switch in the OFF position the DMM should read_24 +/-l.5VDC (no load regulated voltage) and note the reading. Set load switch to ON position and note the meter reading again.

The difference between the two readings should be less than 250mV DC.

Indicate acceptance with check mark on test report.

5.2 Line Regulation 5.2. l Lower the AC line voltage to 103.5V AC.

Note the DMM reading:*

Raise the* AC line voltage to 126.5V AC and note the DMM reading.

The difference between the two readings should be less than 300mVDC.

Indicate acceptance with check mark on test report.

5.3 Output Ripple 5.3.l Set the DMM to measure AC voltage and lOOmV range.

The output should be less than lOmV rms.

Indicate acceptance with check mark on test report.

5.3.2 Switch off the AC line power.

Disconnect PS324-Q2 f/Om tester.

NUMBER ATP455 SHEET 4

  • OF 4

8626 WILBUR AVENUE

  • NORTHRIDGE. CA 91324 * (2131 886-8488
  • Telex No. 65-1303 REV

ATTACHMENT 2

QUALIFICATION TEST REPORT, SURGE WITHSTAND CAPABILITY TESTS, MC170AD-Q2

& MC370AD-Q2 REMOTE MULTIPLEXER/MODULE CASES Report.Number QTR 82-003 CERTIFICATE OF CONFORMANCE State of California County of Los Angeles

, Vice President of Validyne Engineering Corp.,

Gerald A. Merritt Northridge, California, being duly sworn deposes and says that the in-fonnation contained in this report *is the res1:1lt of complete and care-fully conducted tests and is to the best of his knowledge true and correct in all respects.

SUBSCRIBED and sworn to* before me this

~ £tai day of Ct.fl~

, 1983

~QLQ!#l ~lJmcu,,,

Notary Public in and for the

~aunty of Los Angeles, State of California OfFlClAL SEAL SHARLPEUNBEL1f ~~~~~~1A NOTII.R'f LOS ANGEL~S COJ~~O 1~

My comm. expires

./~~a-AA:~

Gerald A. Merritt My commission expires~~-- ~

,j

~

Issue Date: April 1983