REVISIONS LTR ECO DESCRIPTION DATE APPROVED
041105
~ooii~1 o5oooiti pDR A -
~--*
F -----------...----------------------1 SIGNATURE DATE TITLE 1---------------------+----~ AB295-Q2 Analog Board Assembly PROD TEST GI NEERING QUAL CONTROL VEC 304-11/80
~ -U1-a.... (;;:_
tPrl.~
Acceptance Test Procedure r:./c:r / $"o NUMBER ATP445 SHEET 1
OF 7 8626 WILBUR AVENUE
- NORTHRIDGE. CA 91324 * (213) 886-8488
- Telex No. 65*1303 REV
AlidyNE ENQINEEIHNQ COIIPOIIATION 1.0 SCOPE This document defines the Acceptance Test Procedure (ATP) for the AB295-Q2 Analog Board assembly.
This assembly includes 8 s*ub-assembly boards, VEC part number 9860-XX (the low pass frequency, -XX Hz. is to be in accordance with the Sales Order).
The 9860-XX assemblies are to have been previously tested and accepted as ready for shipment.
Any burn-in tests to be specified will be accomplished after completion of this ATP.
Either the end item ATP or a special test procedure appro-priate to a particular contract will define any additional test require-ments.
2.0 EQUIPMENT REQUIRED Table 1 lists the test equipment required to perform the ATP.
Table 1 - E ui ment Re uired for ATP Part No.
Decription Manufacturer or Model Alternate I
AB295 Tester Power Supply
(+/-15 VDC/0.lSA)
Digital Multimeter 3.0 PRELIMINARY PROCEDURE Validyne Lambda Data Precision T-1087 LPD-422FM DP245, DP248 None Commerical Equivalent Commerical Equivalent 3.1 Inspect the AB295-Q2 assembly for accuracy and completeness of assembly.
Log the Low Pass Filter (Ass'y. 9860) serial numbers and positions in which they are installed on the data sheet. Verify retaining screws securely fasten each 9860 assembly in place on the AB295-Q2.
4.0 INITIAL TEST SET-UP 4.1 With the +/-lSVDC power supply "OFF", connect the AB295-Q2 (UUT) to the AB295-Q2 tester.
CAUTION:
Always use caution to observe proper polarity of the mating connector and to turn off the power supply before connecting or disconnec-ting the UUT to the tester.
NUMBER ATP445 SHEET 2
OF 7 REV
A(idyNE ENGINEERING CORPORATION 5.0 FUNCTIONAL TESTS Perform all tests and follow the sequence described.
Apply +/-15 VDC +/-3%
power, with current limits of 150 to 300 mA.
5.1.1 On the AB295-Q2 tester press the RESET switch to obtain CHANNEL ADDRESS indication for QIAN 1.
Place S3 in the #1 position.
Monitor the current test points 11+15V CURRENT" on the tester panel using the 100 mA DC current range of the digital multimeter.
The indicated current shall not exceed 130 mA DC.
5.1.2 Monitor the current test points11-15V CURRENT" on the tester front panel using the 100 mA DC current range of the digital multimeter.
The indi-
. cated current shall not exceed 110 mA DC.
5.2 Reference Voltage Adjustments 5.2.1 Monitor DC volts at TPl with respect to TP3 (ground) of the UUT.
Adjust R2 (+9V ADJ) on UUT (the second potentiometer away from the card edge connector) to obtain +9.000 +/-0.005 VDC.
5.2.2 Monitor DC volts at TP2 with respect to TP3 (ground) of the UUT.
Adjust RS (-9V ADJ) on UUT (the_first potentiometer, closest to the card edge connector) to obtain -9.000 +/-0.005 VDC.
5.3
+/-7V Reference 5.3.1 Measure DC volts at AB295-Q2 tester 11+15V CURRENT" - (minus) test point with respect to ground.
(EA) 5.3.2 Measure DC volts at tester 11+7.5V11 test point.
(EB) 5.3.3 The voltage measured in 5.3.2 shall be (EB) = EA
+/-0.025 voe.
5.3.4 M~asure the DC volts at AB295-Q2 tester 11-15V tURRENT" + (plus) test point with respect to ground.
(EC) 5.3.5 Measure DC volts at tester 11-7.5V" test point.
5.3.6 The voltage measured in 5.3.5 shall be (E0) = EC +/-0.025 VDC.
2 5.4
+12 voe Check Measure DC volts at UUT TPlO with respect to TP3 (ground).
The voltage shall be +12.0 +/-0.6 voe.
NUMBER ATP445 SHEET 3
OF 7 REV
5.5 Analog Multiplexer Tests 5.5.1 Monitor the DC voltage difference between the "INPUT" and "OUTPUT" test points of the AB295-Q2 tester.
(53 in position 1 gives +IOV at all even input channels and -IOV at all odd input channels.)
Press "RESET" to monitor the channel 1 input to output voltage differ-ential.
Press the "STEP" switch once to increment the measurement to channel 2, etc., until all 32 channels have been measured.
At each position of the 32-channel multiplexer, the input to output differential voltage shall be 0.000 +/-0.020 voe.
Also note that the "INPUT FAULT" indicator remains milit (at front panel of tester).
5.5.2 Repeat the tests described in 5.5.1, except place S3 in position 2 (which gives +lOV at all odd input channels and -lOV at all even input channels).
At each position of the 32-channel multiplexer, the input to output differential voltage shall be 0.000 +/-0.020 voe.
Also note that the "INPUT FAULT" indicator remains milit (at the front panel of tester).
5.5.3 After completion of above tests, remove power and disconnect UUT from tester. Complete data*entries in TEST REPORT forms and indicate acceptance or note deficiencies.
NUMBER ATP445 SHEET 4
OF 7 REV
(
S/0 W/0 Paragraph/Step ASSY TEST REPORT AB295-Q2 ANALOG BOARD ASSEMBLY CUSTOMER SERIAL NO.
Accepted Specification 3.1 Visual Inspection Ass'y accurate and complete.
Screws tight.
POSITION Ch 1-4 Ch 5-8 Ch 9-12 Ch 13-16 5.1.1
+15V CURRENT 5.1. 2 -15V CURRENT 5.2.1 * +9V ADJUST 5.2.2 -9V ADJUST 5.3.1 E =
A 5.3.2 E =
B 5.3.3 E =
A 2
5.3.4 EC =
5.3.5 ED =
5.3.6 EC =
2 5.4
+12 VDC check 9860 S/N POS 9860 S/N 17-20 21-24 25-28 29-32 VDC VDCJ VDC VDC VDCJ VDC NUMBER ATP445 130 mA DC Max.
110 mA DC Max.
+9.000
+/-.005 VDC
-9.000
+/-.005 VDC ED= EC +/-0.025 2
VDC
+12.0 +/-0.6 VDC REV SHEET 5 OF 7 8626 WILBl.JR AVENI.LE *~~ORJHRIDGE CA 91324
- 12131 886-8488 *~elexNo 65-1303
(
\\
(
TEST REPORT AB295-Q2 ASSY ANALOG BOARD ASSEMRT;Y S/0 W/0 Paragraph/Step 5.5.1 Multiplexer Differential Voltage (+lOV@ EVEN, -lOV@ ODD)
INPUT FAULT INDICATOR Chl 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 CUSTOMER SERIAL NO.** ---------
- Accepted Specification Unlit 0.00 +/-0.02 VDC 0.00 +/-0.02 VDC NUMBER REV ATP445 SHEET 6 OF 7 8626 WILBUR AVENUE
- NORTHRIDGE. CA 91324 * (213) 886-8488
- Telex NC)_. 6ji_~03 __ _
AlidyNE l!NGINl!IHUNG COllfOOIIATION TEST REPORT AB295-Q2 ASSY ANALPG BQABP ASSEMBLY S/0 W/0 Paragraph/Step 5.5.2 Multiplexer Differential Voltage (-lOV@ EVEN, +lOV@ ODD)
INPUT FAULT INDICATOR Chl 2
3
.4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 CUSTOMER SERIAL NO.
Accepted NUMBER ATP445 Specification Unlit 0.00 +/-0.02 VDC 0.00 +/-0.02 VDC REV SHEET 7 OF 7