ML18120A002

From kanterella
Jump to navigation Jump to search
8 to Fire Hazards Analysis Report, Volume 1, Intro - Table of Contents
ML18120A002
Person / Time
Site: Crane Constellation icon.png
Issue date: 04/06/2018
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18117A343 List: ... further results
References
TMI-18-047
Download: ML18120A002 (8)


Text

fhar.tmi/Rev. 27 iv TABLE OF CONTENTS SECTION TITLE PAGE

1.0 INTRODUCTION

1-1 1.1 Background and Purpose 1-1 2.0 METHODOLOGY - FIRE HAZARDS ANALYSIS AND APPENDIX R EVALUATION 2.1 Introduction 2-1 2.2 Information Collection 2-2 2.3 Evaluation 2-8 3.0 APPENDIX R SECTION IIIG EVALUATION 3-1 3.1 Deleted 3-1 3.2 Deleted 3-1 3.3 Deleted 3-1 3.4 Deleted 3-1 3.5 Deleted 3-1 3.6 Deleted 3-1 3.7 Deleted 3-1 3.8 Deleted 3-1 3.9 Deleted 3-1 3.10 Valves 3-2 3.11 Safe Shutdown Equipment and Circuits 3-2 3.12 Alternative Shutdown Capability 3-4 3.13 Spurious Operation of Components 3-34 3.14 Exemptions 3-37

fhar.tmi/Rev. 27 v

TABLE OF CONTENTS (Contd)

SECTION TITLE PAGE 4.0 FIRE HAZARDS ANALYSIS 4-1 4.1 REACTOR BUILDING 4-1 4.1.1 Fire Zone, RB-FZ-1a 4-3 4.1.2 Fire Zone, RB-FZ-1b 4-5 4.1.3 Fire Zone, RB-FZ-1c 4-7 4.1.4 Fire Zone, RB-FZ-1d 4-9 4.1.5 Fire Zone, RB-FZ-1e 4-11 4.1.6 Fire Zone, RB-FZ-2 4-13 4.1.7 Fire Zone, RB-FZ-3 4-15 4.2 AUXILIARY BUILDING 4-17 4.2.1 Fire Area AB-FA-1 4-18 4.2.2 Fire Zone, AB-FZ-2 4-21 4.2.3 Remainder of Auxiliary Building 4-24 4.2.3.1 Fire Zone, AB-FZ-1 4-24 4.2.3.2 Fire Zones, AB-FZ-2a, 2b, 2c 4-26 4.2.3.3 Fire Zone, AB-FZ-3 4-28 4.2.3.4 Fire Zone, AB-FZ-4 4-31 4.2.3.5 Fire Zone, AB-FZ-5 4-34 4.2.3.6 Fire Zone, AB-FZ-6 4-38 4.2.3.6a Fire Zone, AB-FZ-6a 4-41 4.2.3.7 Fire Zone, AB-FZ-7 4-43 4.2.3.8 Fire Zone, AB-FZ-8 4-45 4.2.3.9 Fire Zone, AB-FZ-9 4-47 4.2.3.10 Fire Zone, AB-FZ-10 4-49 4.2.3.11 Fire Zone, AB-FZ-11 4-51

fhar.tmi/Rev. 27 vi TABLE OF CONTENTS (Contd)

SECTION TITLE PAGE 4.3 INTERMEDIATE BUILDING 4-53 4.3.1 Fire Zone, IB-FZ-1 4-54 4.3.2 Fire Zone, IB-FZ-2 4-56 4.3.3 Fire Zone, IB-FZ-3 4-58 4.3.4 Fire Zone, IB-FZ-4 4-60 4.3.5 Fire Zone, IB-FZ-5 4-63 4.3.6 Fire Zone, IB-FZ-6 4-65 4.3.7 Fire Zone, IB-FZ-7 4-67 4.3.8 Fire Zone, IB-FZ-8 4-68 4.4 CONTROL BUILDING 4-71 4.4.1 Fire Area, CB-FA-1 4-72 4.4.2 Fire Area, CB-FA-2a 4-74 4.4.3 Fire Area, CB-FA-2b 4-76 4.4.4 Fire Area, CB-FA-2c 4-77 4.4.5 Fire Area, CB-FA-2d 4-79 4.4.6 Fire Area, CB-FA-2e 4-81 4.4.7 Fire Area, CB-FA-2f 4-83 4.4.8 Fire Area, CB-FA-2g 4-85 4.4.9 Fire Area, CB-FA-3a 4-87 4.4.10 Fire Area, CB-FA-3b 4-89 4.4.11 Fire Area, CB-FA-3c 4-91 4.4.12 Fire Area, CB-FA-3d 4-93 4.4.13 Fire Area, CB-FA-4a 4-95 4.4.14 Fire Area, CB-FA-4b 4-97 4.4.15 Fire Zone, CB-FZ-5a 4-99 4.4.16 Fire Zone, CB-FZ-5b 4-100

fhar.tmi/Rev. 27 vii TABLE OF CONTENTS (Contd)

SECTION TITLE PAGE 4.5 DIESEL GENERATOR BUILDING 4-102 4.5.1 Fire Area, DG-FA-1 4-103 4.5.2 Fire Area, DG-FA-2 4-105 4.6 INTAKE SCREEN AND PUMPHOUSE 4-107 4.6.1 Fire Zone, ISPH-FZ-1 4-108 4.6.2 Fire Zone, ISPH-FZ-2 4-110 4.6.3 Fire Zone, ISPH-FZ-3 4-112 4.6.4 Fire Area, ISPH-FA-2 4-114 4.7 FUEL HANDLING BUILDING 4-116 4.7.1 Fire Zone, FH-FZ-1 4-117 4.7.2 Fire Zone, FH-FZ-2 4-119 4.7.3 Fire Zone, FH-FZ-3 4-122 4.7.4 Fire Zone, FH-FZ-4 4-124 4.7.5 Fire Zone, FH-FZ-5 4-126 4.7.6 Fire Zone, FH-FZ-6 4-128 4.8 TURBINE BUILDING 4-130 4.8.1 Fire Area, TB-FA-1 4-130 4.9 AIR INTAKE TUNNEL 4-134 4.9.1 Fire Zone, AIT-FZ-1 4-134 4.9.2 Fire Zone, AIT-FZ-1a 4-136 4.10 Radwaste Storage Facility 4-138 4.10.1 Fire Area RWSF-FA-1 4-138 4.11 Waste Handling and Packaging Facility 4-140 4.11.1 Fire Area WHPF-FA-1 4-140 4.11.2 Fire Area WHPF-FA-2 4-141

fhar.tmi/Rev. 27 viii TABLE OF CONTENTS (Contd)

SECTION TITLE PAGE 4.12 Chemical Cleaning Building 4-144 4.12.1 Fire Zone CCB-FZ-1 4-144 4.12.2 Fire Zone CCB-FZ-2 4-145 4.13 Station Blackout (SBO) Diesel Generator Bldg.

4-148 4.13.1 Fire Area SBO-FA-1 4-148 4.13.2 Fire Area SBO-FA-2 4-150 4.14 Original Steam Generator Storage Facility (OSGSF) 4-151 4.14.1 Fire Area OSGSF-FA-1 4-151 4.15 Outage Equipment Storage Building (OESB) 4-153 4.15.1 Fire Area OESB-FA-1 4-153 5.0 TMI-1 COMPARISON TO THE REQUIREMENTS OF 5-1 NRC BRANCH TECHNICAL POSITION APCSB 9.5-1 6.0 PROTECTION AGAINST WATER SPRAY TO 6-1 CONFORM WITH 10CFR50 APPENDIX R

fhar.tmi/Rev. 27 ix LIST OF ATTACHMENTS

-0 System Availability for a Fire in Fire Zone/Area

-1 Protected Cables for Appendix R Modifications

-2 Deleted

-3 Safe Shutdown Equipment

-4 Flow Diagrams for Fire Safe Shutdown Systems

-5 Component Availability for a Fire in Fire Area/Zone

-6 Cables and Components in Fire Area/Zone

-7A Manual Actions Required for Hot Shutdown in Appendix R III.G.2 Fire Areas/Zones

-7B Manual Actions Required for Hot Shutdown in Appendix R III.G.3 Fire Areas/Zones

-7C Manual Actions and Repairs Required for Cold Shutdown in Any Fire Area/Zone

-8 Appendix R Emergency Lights

fhar.tmi/Rev. 27 x

LIST OF DRAWINGS Drawing No.

Title 1-FHA-001 Fire Area Layout - Legend and Notes 1-FHA-002 Fire Area Layout - Turbine Bldg. - Plan Floor El. 305'-0" 1-FHA-003 Fire Area Layout - Turbine Bldg. - Plan Floor El. 305'-0" 1-FHA-004 Fire Area Layout - Turbine Bldg. - Plan Floor El. 322'-0" 1-FHA-005 Fire Area Layout - Turbine Bldg. - Plan Floor El. 322'-0" 1-FHA-006 Fire Area Layout - Turbine Bldg. - Plan Floor El. 355'-0" 1-FHA-007 Fire Area Layout - Turbine Bldg. - Plan Floor El. 355'-0" 1-FHA-008 Fire Area Layout - Turbine Bldg. - Section L-L 1-FHA-009 Fire Area Layout - Turbine Bldg. - Section L-L 1-FHA-010 Fire Area Layout - Turbine Bldg. - Section N-N 1-FHA-011 Fire Area Layout - Turbine Bldg. - Section M-M 1-FHA-012 Fire Area Layout - Turbine Bldg. - Section P-P 1-FHA-013 Fire Area Layout - Turbine Bldg. - Section K-K 1-FHA-014 Fire Area Layout - Turbine Bldg. - Section K-K 1-FHA-015 Fire Area Layout - Turbine Bldg. - Section O-O 1-FHA-016 Fire Area Layout - Turbine Bldg. - Section Q-Q 1-FHA-017 Fire Area Layout - Reactor Bldg. - Plan Floor El. 281'-0" 1-FHA-018 Fire Area Layout - Reactor Bldg. - Plan Floor El. 308'-0" 1-FHA-019 Fire Area Layout - Reactor Bldg. - Plan El. 331'-0" 1-FHA-020 Fire Area Layout - Reactor Bldg. - Plan Floor El. 346'-0" 1-FHA-021 Fire Area Layout - Reactor Bldg. - Plan Floor El. 365'-6" & 355'-0" 1-FHA-022 Fire Area Layout - Reactor Bldg. - Section A-A & C-C 1-FHA-023 Fire Area Layout - Reactor Bldg. - Section B-B 1-FHA-024 Fire Area Layout - Reactor Bldg. - Plan Floor El. 382'-0" 1-FHA-025 Fire Area Layout -

Auxiliary Bldg. & Air Intake Tunnel -

Partial Plans & Sections 1-FHA-026 Fire Area Layout -

Auxiliary & Fuel Handling Bldgs. -

Plan Floor El. 281'0"

fhar.tmi/Rev. 27 xi LIST OF DRAWINGS (Contd)

Drawing No.

Title 1-FHA-027 Fire Area Layout

- Auxiliary & Fuel Handling Bldgs. -

Plan Floor El. 305'0" 1-FHA-028 Fire Area Layout

- Auxiliary & Fuel Handling Bldgs. -

Plan Floor El. 331'0" & 329'-0" 1-FHA-029 Fire Area Layout

- Fuel Handling Bldgs. - Plan Fllor El. 348'-0" 1-FHA-030 Fire Area Layout

- Auxiliary & Fuel Handling Bldgs. - Sections 1-FHA-031 Fire Area Layout

- Auxiliary & Fuel Handling Bldgs. - Sections 1-FHA-032 Fire Area Layout

- Auxiliary Bldg. - Sections 1-FHA-033 Fire Area Layout

- Fuel Handling Bldg. - Sections 1-FHA-034 Fire Area Layout

- Control Tower - Plan Floor El. 285'-0" & 306'-0" 1-FHA-035 Fire Area Layout

- Control Tower - Plan Floor El. 322'-0" & 338-6 1-FHA-036 Fire Area Layout

- Control Tower - Plan Floor El. 355'-0" & 380-0 1-FHA-037 Fire Area Layout

- Control Tower - Section A-A 1-FHA-038 Fire Area Layout

- Control Tower - Section B-B 1-FHA-039 Fire Area Layout

- Intermediate Bldg. - Plan Floor El. 295'-0" 1-FHA-040 Fire Area Layout

- Intermediate Bldg. - Plan Floor El. 305'-0" 1-FHA-041 Fire Area Layout

- Intermediate Bldg. - Plan Floor El. 322'-0" 1-FHA-042 Fire Area Layout

- Intermediate Bldg. - Plan Floor El. 355'-0" 1-FHA-043 Fire Area Layout

- Intermediate Bldg. - Sections 1-FHA-044 Fire Area Layout

- Diesel Generator Bldg. - Plan Floor El. 305'-0" 1-FHA-045 Fire Area Layout

- Diesel Generator Bldg. - Sections 1-FHA-046 Fire Area Layout

- Intake Screen and Pump House - Plan Floor El. 308'-0"