Rev 5 to Salem Nuclear Generating Station Offsite Dose Calculation Manual
ML18093B357
Person / Time
Site: Salem  
Issue date: 12/21/1988
From:
Public Service Enterprise Group
To:
Shared Package
ML18093B356 List:
References
PROC-881221, NUDOCS 8901040016
Download: ML18093B357 (96)


Text

SALEM NUCLEAR GENERATING STATION OFFSITE DOSE CALCULATION MANUAL Revision 5 12/21/88 Approval

~~

SORC Chairman:


~

---e9o104ocfa6 ss1227 l

PDR ADOCK 05000272 p

PNU Date: tyZrj;r"' Mtg. # Q0-11(

I

Salem ODCM Rev. 5 12/21/88 SALEM NUCLEAR GENERATING STATION OFFSITE DOSE CALCULATION MANUAL Table of Contents Introduction.....

1.0 Liquid Effluents 1

1.1 Radiation Monitoring Instrumentation and Controls.

2

1. 2 Liquid Ef.fluent Monitor Setpoint Determination 3

1.2.1 Liquid Effluent Monitors (Radwaste, Steam Generator Blowdown and Service Water) 4 1.2.2 Conservative Default Values

....... 5 1.3 Liquid Effluent Concentration Limits -

10 CFR 20 7

1.4 Liquid Effluent Dose Calculations -

10 CFR 50...

7

  • 1.4.1 Member of the Public Dose - Liquid Effluents 8

1.4.2 Simplified Liquid Effluent Dose Calculation. 10 1.5 Secondary Side Radioactive Liquid Effluents -

Dose Calculations During Primary to Secondary Leakage.. 11

1. 6 Liquid Effluent Dose Projection
  • *........ 13 2.0 Gaseous Effluents 2.1 Radiation Monitoring Instrumentation and Controls

. 15 2.2 Gaseous Effluent Monitor Setpoint Determination.. 17 2.2.1 Containment and Plant Monitor

....... 17 2.2.2 Conservative Default Values

........ 19 2.3 Gaseous Effluent Instantaneous Dose Rate Calculations -

10 CFR 20.... *.

. 20 2.3.1 Site Boundary Dose Rate - Noble Gases

. 20 2.3.2 Site Boundary Dose Rate -

Radioiodine and Particulates

  • .... *.. 21 2.4 Noble Gas Effluent Dose Calculations -

10 CFR 50 23 2.4.1 UNRESTRICTED AREA Dose -

Noble Gases **.. 23 2.4.2 Simplified Dose Calculation for Noble Gases. 23

  • 2.5 Radioiodine and Particulate Dose Calculations 10 CFR 5 0

.... *...... * *........ 2 5 2.5.1 UNRESTRICTED AREA Dose -

Radioiodine and Particulates

. 25 2.5.2 Simplified Dose Calculation for Radioiodines and Particulates

......

  • 26 2.6 Secondary Side Radioactive Gaseous Effluents and Dose Calculations

..... 27 2.7 Gaseous Effluent Dose Projection

. 31 3.0 Special Dose Analyses 3.1 Doses Due To Activities Inside the SITE BOUNDARY.. 32 3.2 Doses to MEMBERS OF THE PUBLIC -

40 CFR 190.... 33 3.2.1 Effluent Dose Calculations

.... 34 3.2.2 Direct Exposure Determination

....... 34

Salem ODCM Rev. 5 12/21/88 Table of Contents - Continued 4.0 Radiological Environmental Monitoring Program 4.1 Sampling Program.......*.

4.2 Interlaboratory Comparison Program

. 35

. 35

  • 36 Tables 1-1 Parameters for Liquid Alarm Setpoint Determination

. 1-2 1-3 1-4 2-1 2-2 2-3 2-4 2-5 A-1 A-2 B-1 B-2 C-5 Appendices Unit 1

. 4 0 Parameters for Liquid Alarm Setpoint Determination Unit 2

. 41 Site Related Ingestion Dose Commitment Factors, Aio

....... 43 Bioaccumulation Factors (BFi). *......... 45 Dose Factors for Noble Gases ****..*.... 47 Parameters for Gaseous Alarm Setpoint Determinations Unit 1

. 4 8 Parameters for Gaseous Alarm Setpoint Determinations Unit 2

. 4 9 Controlling Locations, Pathways and Atmospheric Dispersion for Dose Calculations Pathway Dose Parameters - Atmospheric Releases Calculation of Effective MPC - Unit 1. *...

  • Calculation of Effective MPC - Unit 2......

Adult Dose Contributions Fish and Drinking Water Pathways Unit 1

  • 50 51

. A-4

. A-5 B-5 Adult Dose Contributions Fish and Drinking Water Pathways Unit 2

. B-5 Effective Dose Factors

.............. C-5 Appendix A - Evaluation of Conservative, Default MPC Appendix B Appendix c Appendix D Value for Liquid Effluents..... *. A-1

- Technical Basis for Effective Dose Factors -

Liquid Radioactive Effluents...... B-1

- Technical Bases for Effective Dose Factors -

Gaseous Radioactive Effluent.s

... c-1

- Radiological Environmental Monitoring Program -

Sample Type, Location and Analysis. *. D-1

Introduction Salem ODCM Rev. 5 12/21/88 SALEM NUCLEAR GENERATING STATION OFFSITE DOSE CALCULATION MANUAL The Salem Offsite Dose Calculation Manual (ODCM) describes the methodology and parameters used in: 1) the calculation of radioactive liquid and gaseous effluent monitoring instrumentation alarm/trip setpoints; and 2) the calculation of radioactive liquid and gaseous concentrations, dose rates and cumulative quarterly and yearly doses.

The methodology stated in this manual is acceptable for use in demonstrating compliance with 10 CFR 20.106, 10 CFR 50, Appendix I and 40 CFR 190.

More conservative calculation methods and/or conditions (e.g.,

location and/or exposure pathways) expected to yield higher computed doses than appropriate for the maximally exposed person may be assumed in the dose evaluations.

The ODCM will be maintained at the station for use as a reference guide and training document of accepted methodologies and calculations.

Changes will be made to the ODCM calculation methodologies and parameters as is deemed necessary to ensure reasonable conservatism in keeping with the principles of 10 CFR 50.36a and Appendix I for demonstrating radioactive effluents are ALARA.

NOTE:

As used throughout this document, excluding acronyms, words appearing all capitalized denote the application of definitions as used in the Salem Technical Specifications.

1

/

Salem ODCM Rev. 5 12/21/88 1.0 Liquid Effluents 1.1 Radiation Monitoring Instrumentation and controls The liquid effluent monitoring instrumentation and controls at Salem for controlling and monitoring normal radioactive material releases in accordance with the Salem Radiological Effluent Technical Specifications are summarized as follows:

1)

Alarm (and Automatic Termination) -

1-R18 (Unit 1) and 2-R18 (Unit 2) provide the alarm and automatic termination of liquid radioactive material releases as required by Technical Specification 3.3.3.8.

1-Rl9 A,B,C,and D provide the alarm and isolation function for the Unit 1 steam generator blowdown lines.

2-Rl9 A,B,C and D provide this function for Unit 2.

2)

Alarm Conly) - The al.arm functions for the Service Water System are provided by the radiation monitors on the Containment Fan Cooler discharges (1-R 13 A,B,C,D

~nd E for Unit 1 and 2-R 13 A,B,and C for Unit 2).

Releases from the secondary system are routed through the Chemical Waste Basin where the effluent is monitored (with an alarm function) by R37 prior to release to the environment.

Liquid radioactive! waste flow diagrams with the applicable, associated radiation monitoring instrumentation and controls are presented as Figures 1-1 and 1-2 for Units 1 and 2, respectively.

2

Salem ODCM Rev. 5 12/21/88 1.2 Liquid Effluent Monitor Setpoint Determination Per the requirements of Technical Specification 3.3.3.8, alarm setpoints shall be established for the liquid effluent monitoring instrumentation to ensure that the release concentration limits of Specification 3.11.1.1 are met (i.e., the concentration of radioactive material released in liquid effluents to UNRESTRICTED AREAS shall be limited to the concentrations specified in 10 CFR 20, Appendix B, Table II, Column 2, for radionuclides and 2.0E-04 uCi/ml for dissolved or entrained noble gases).

The following equation* must be satisfied to meet the liquid effluent restrictions:

where:

C (F+f)

(1.1) c ~

f c

=

the effluent concentration limit of Technical Specification (3.11.1.1) implementing the 10 CFR 20 MPC for the site, in uci/ml c

= the setpoint, in uci/ml, of the radioactivity monitor measuring the radioactivity concentration in the effluent line prior to dilution and subsequent release; the setpoint, represents a value which, if exceeded, would result in concentrations exceeding the limits of 10 CFR 20 in the UNRESTRICTED AREA f

= the flow rate at the radiation monitor location, in volume per unit time, but in the same.units as F, below F = the dilution water flow rate as measured prior to the release point, in volume per unit time (Note that if no dilution is provided, c~ c.

Also, note that when (F) is large compared to (f), then (F + f) = F.]

Adapted from NUREG-0133*

3

Salem ODCM Rev. 5 12/21/88 1.2.1 Liquid Effluent Monitors CRadwaste, steam Generator Blowdown, Chemical Waste Basin and Service Water.

The setpoints for the liquid effluent monitors at the Salem Nuclear Generating station are determined by the following equations:

MPCe

  • SEN

+ bkg (1.2)

RR with:

MPCe =

(1.3) where:

SP

= alarm setpoint corresponding to the maximum allowable release rate (cpm)

MPCe = an effective MPC value for the mixture of radionuclides in the effluent stram (uCi/ml)

Ci = the concentration of radionuclide i in the undiluted liquid effluents (uCi/ml)*

MPCi =

SEN

=

cw

=

RR

=

bkg =

the MPC value corresponding to radionuclide i from 10 CFR 20, Appendix B, Table II, Column 2 (uCi/ml) the sensitivity value to which the monitor is calibrated (cpm per uCi/ml) the circulating water flow rate (dilution water flow) at the time of release (gal/min) the liqliid effluent release rate (gal/min) the background of the monitor (cpm) 4

Salem ODCM Rev. 5 12/21/88 The radioactivity monitor setpoint equation (1.2) remains valid during outages when the circulating water dilution is potentially at its lowest value.

Reduction of the waste stream flow (RR) may I

be necessary during these periods to meet the discharge criteria.

However, in order to maximize the available plant discharge dilution and thereby minimize the potential offsite doses, releases from either Unit-1 or Unit-2 may be routed to either the Unit or Unit-2 Circulating Water System discharge.

This routing is possible via interconnections between the Service Water Systems (see Figures 1 and 2).

Procedural restrictions prevent simultaneous releases from either a single unit or both units into a single Circulating Water System discharge.

1.2.2 Conservative Default Values.

Conservative alarm setpoints may be determined through the use of default parameters.

Tables 1-1 and 1-2 summarize all current default values in use for Salem Unit-1 and Unit-2, respectively.

They are based upon the following:

a) substitution of the effective MPC value with a default value of lE-05 uCi/ml for radwaste releases (refer to Appendix A for justification);

b) for additional conservatism*, substitution of the I-131 MPC value of 3E-07 uCi/ml for the R19 Steam Generator Use of the effective MPC value as derived in Appendix A may be non-conservative for the R19 steam Generator blowdown monitors and R37 Chemical Waste Basin monitors where I-131 transfer during primary to secondary leakage may potentially be more controlling.

5

Salem ODCM Rev. 5 12/21/88 blowdown monitors, lR13** Service Water monitor and R37 Chemical Waste Basin monitor; c) substitutions of the operational circulating water flow with the lowest flow, in gal/min; and, d) substitutions of the effluent release rate with the highest allowed rate, in gal/min.

With pre-established alarm setpoints, it is possible to control the radwaste release rate (RR) to ensure the inequality of equation (1.2) is maintained under changing values for MPCe and for differing Circulating Water System dilutions.

So, for* conservatism no dilution is used for determining a 2Rl3 default alarm setpoint.

Because no dilution is considered and the. 2R13 monitor sensitivity is high, the MPCe of lE-05 uCi/ml is used in calculating the alarm setpoint (otherwise using 3E-07 uCi/ml would result in an alarm setpoint of 1 cpm)~

6

Salem ODCM Rev. 5 12/21/88 1.3 Liquid Effluent Concentration Limits -

10 CFR 20 Technical Specification 3.11.1.1 limits the concentration of radioactive material in liquid effluents (after dilution in the Circulating Water System) to less than the concentrations as specified in 10 CFR 20, Appendix B, Table II, Column 2 for radionuclides other than noble gases.

Noble gases are limited to a diluted concentration of 2.0E-04 uCi/ml.

Release rates are controlled and radiation monitor alarm setpoints are established as addressed above to ensure that these concentration limits are not exc.eeded.

However, in the event any liquid release results in an alarm setpoint being exceeded, an evaluation of compliance with the concentration limits 6f Technical Specification 3.11.1.1 may be performed using the following equation:

where:

C*

l MPC* l RR cw RR 5 1 (1.4)

CW + RR

= actual concentration of radionuclide i as measured in the undiluted liquid effluent (uCi/ml)

=

the MPC value corresponding to radionuclide i from 10 CFR 20, Appendix B, Table II, Column 2 (uCi/ml)

= 2E-04 uci/ml for dissolved or entrained noble gases

= the actual liquid effluent release rate. (gal/min)

= the actual circulating water flow rate (dilution water flow) at the time of. the release (gal/min) 7

Salem ODCM Rev. 5 12/21/88 1.4 Liguid Effluent Dose Calculation -

10 CFR 50 1.4.1 MEMBER OF THE PUBLIC Dose - Liquid Effluents.

Technical Specification 3.11.1. 2 limits the dose or dose commitment to MEMBERS OF THE PUBLIC from radioactive materials in liquid effluents from each unit of the Salem Nuclear Generating Station to:

during any calendar quarter; 5 1.5 mrem to total body per unit 5 5.0 mrem to any organ per unit during any calendar year; 5 3.0 mrem to total body per unit 5 10.0 mrem to any organ per unit.

Per the surveillance requirements of Technical Specification 4.11.1.2, the following calculation methods may be used for determining the dose or dose commitment due to the liquid radioactive effluents from Salem.

1.67E-02

  • VOL (1. 5) cw where:

D0

= dose or dose commitment to organ o, i'ncluding total body (mrem)

Aio =

s~te-related ingestion dose commitment factor to the total body or any organ o for radionuclide i (mrem/hr per uCi/ml)

Ci

=

average concentration of radionuclide i, in undiluted liquid effluent represent.ative of the volume VOL (uCi/ml) 1 VOL =

volume of liquid effluent released (gal) cw

=

average circulating water discharge rate during release period (gal/min) 1.67E-02 = conversion factor (hr/min)

).

8

Salem ODCM Rev. 5 12/21/88 The site-related ingestion dose/dose commitment factors (Ai 0 ) are presented in Table 1-3 and have been derived in accordance with of NUREG-0133 by the equation:

= 1.14E+05 [(UI

  • Bii) + (UF
  • BFi)J DFi (1.6) where:

Aio = composite dose parameter for the total body or critical organ o of an adult for radionuclide i, for the fish and invertebrate ingestion pathways (mrem/hr per uCi/ml)

UI

= adult invertebrate consumption (5 kg/yr)

Bii = bioaccumulation factor for radionuclide i in inver~ebrates from Table 1-4 (pCi/kg per pCi/l)

UF

= adult fish consumption (21 kg/yr)

BFi = bioaccumulation factor for radionuclide i in fish from Table 1-4 (pCi/kg per pCi/l)

DFi = dose conversion factor for nuclide i for adults in pre-selected organ, o, from Table E-11 of Regulatory Guide 1.109 (mrem/pCi) 1.14E+05 =conversion factor (pCi/uCi *ml/kg per hr/yr)

The radionuclides included in the periodic dose assessment per the requirements of Technical Specification 3/4.11.1.2 are those as identified by gamma spectral analysis of the liquid waste samples collected and analyzed per the requirements of Technical Specification 3/4.11.1.1, Table 4.11-1.

Radionuclides requiring radiochemical analysis (e.g., Sr-89 and Sr-90) will be added to the dose analysis at a frequency consistent with the required minimum analysis frequency of Technical Specification Table 4.11-1.

9

Salem ODCM Rev. 5 12/21/88 1.4.2 Simplified Liquid Effluent Dose Calculation.

In lieu of the individual radionuclide dose assessment as presented in Section 1.4.1, the following simplified dose calculation equation may be used for demonstrating compliance with the dose limits of Technical Specification 3.11.1.2.

(Refer to Appendix B for the derivation and justification for this simplified method.)

Total Body 1.21E+03

  • VOL

=

(1.7) cw Maximum Organ 2.52E+04

  • VOL

=

(1.8) cw where:

Ci

= average concentration of radionuclide i, in undiluted

\\

liquid effluent representative of the volume VOL (uCi/ml)

VOL = volume of liquid effluent released (gal) cw

= average circulating water discharge rate during release period (gal/min)

Dtb = conservatively evaluated total body dose (mrem)

Dmax = conservatively evaluated maximum organ dose (mrem) 1.21E+03 = conversion factor (hr/min) and the conservative total body dose conversion factor (Fe-59, total body -- 7.27E+04 mrem/hr per uCi/ml) 2.52E+04 = conversion factor (hr/min) and the conservative maximum organ dose conversion factor (Nb-95, GI-LLI -- 1.51E+06 mrem/hr per uCi/ml) 10

/

Salem ODCM Rev. 5 12/21/88 1.5 Secondary Side Radioactive Liquid Effluents and Dose Calculations During Primary to Secondary Leakage During periods of~primary to secondary leakage (i.e., steam.

generator tube leaks), radioactive material will be transmitted from the primary system to the secondary system.

The potential exists for the release of radioactive material to the off-site environment (Delaware River) via secondary system discharges.

Potentially significant radioactive material levels and potential releases are controlled/monitored by the Steam Generator blowdown monitors (R19) and the Chemical Waste Basin monitor (R37).

However to ensure compliance with the regulatory limits on radioactive material releases, it may be desirable to account for potential releases from the secondary system during periods of primary to secondary leakage.

Any potentially significant releases will be via the Chemical Waste Basin with the major source of activity being the Steam Generator blowdown.

With identified radioactive material levels in the secondary system, appropriate samples should be collected and analyzed for the principal gamma emitting radionuclides.

Based on the identified radioactive material levels and the volume of water discharged, the resulting environmental doses may be calculated based on equation (1.5).

Because the release rate from the secondary system is indirect 11

Salem ODCM Rev. 5 12/21/88 (e.g., SG blowdown is normally routed to condenser where the condensate clean-up system will remove much of the radioactive material), samples should be collected from the 'final release point (i.e., Chemical Waste Basin) for quantifying the radioactive material releases.

However, for conservatism and ease of controlling and quantifying all potential release paths, it is prudent to sample the SG blowdown and to assume all radioactive material is released directly to the environment via the Chemical Waste Basin.

This approach while. not exact, is conservative and ensures timely analysis for regulatory compliance.

Accounting for radioactive material retention of the condensate clean-up system ion exchange resins may be needed to more accurately account for actual releases

  • 12

Salem ODCM Rev. 5 12/21/88 1.6 Liguid Effluent Dose Projections Technical Specification 3.11.1.3 requires that the liquid radioactive waste processing system be used to reduce the radioactive material levels in the.liquid waste prior to release when the quarterly projected doses exceed:

0.375 mrem to the total body, or 1.25 mrem to any organ.

The applicable liquid waste processing system for maintaining radioactive material releases ALARA is the ion exchange system as delineated in Figure 1-3.

Alternately, the waste evaporator as presented in the Salem FSAR has processing capabilities meeting the NRC ALARA design. requirements and may be used in conjunction or in lieu of the ion exchange system for waste processing requirements in accordance with Technical Specification 3.11.1.3.

These processing requirements are applicable to each unit individually.

Exceeding the projected dose requiring processing prior to release for one unit does not in itself dictate processing requirements for the other unit.

Dose projections are made at least once per 31 days by the following equations:

Dtbp =

0maxp =

Dtb (91 I d)

Dmax (91 I d) 13 (1.9)

(1.10)

where:

Dtbp Dtb 0maxp d

91

=

=

=

Salem ODCM Rev. 5 12/21/88 the total body dose projection for current calendar quarter (mrem) the total body dose to date for current calendar quarter as determined by Equation 1.5 or 1.7 (mrem) the maximum organ dose projection for current calendar quarter (mrem)

= the maximum organ dose to date for current calendar quarter as determined by Equation 1.5 or 1.7. (mrem) the number of days to date for current calendar quarter

= the number of days in a calendar quarter 14

Salem ODCM Rev. 5 12/21/88 2.0 Gaseous Effluents 2.1 Radiation Monitoring Instrumentation and Controls The gaseous effluent monitoring instrumentation and controls at Salem for controlling and monitoring normal radioactive material releases in accordance with the Radiological Effluent Technical Specifications are summarized as follows:

1)

Waste Gas Holdup System - The vent header gases are collected by the waste gas holdup system.

Gases may be recycled to provide cover gas for the eves hold-up tank or held in the waste gas tanks for decay prior to release.

Waste gas decay tanks are batch released after sampling and analysis.

The tanks are discharged via the Plant Vent.

1-R41C provides noble gas monitoring and automatic isolation of waste gas decay tank releases for Unit-1; this function is provided by 2-R41C for Unit-2.

2)

Containment Purge and Pressure/Vacuum Relief -

Containment purges and pressure/vacuum reliefs are released to the atmosphere via the respective unit Plant Vent.

Noble gas monitoring and auto isolation function are provided by 1-R41C for Unit-1 and 2-R41C for Unit-2.

Additionally, in accordance with Technical Specification 3.3.3.9, Table 3.3-13, 1-R12A and 2-R12A may be used to provide the containment monitoring and automatic isolation function during purge and pressure/vacuum reliefs.*

3)

Plant Vent -

The Plant Vent for each respective unit receives discharges from the waste gas hold-up system, condenser evacuation system, containment purge and pressure/vacuum reliefs, and the Auxiliary Building ventilation.

Effluents are monitored by R41C, a flow through gross activity monitor (for noble gas monitoring).

Additionally, in-line gross activity monitors (1-R16 and The R12A monitors also provide the safety function of containment iso the event of a fuel handling accident during refueling.

During M

accordance with Technical Specification 3/4.3.3, Table 3.3-6, alarm/trip setpoint shall be established at twice background, provid indication and containment isolation accompanying unexpected inc containment airborne radioactive material levels indicative of a fuel tion.

The R41C monitor may also provide this function if the R12A m

inoperable during MODE 6.

15

Salem ODCM Rev. 5 12/21/88

3)

Plant Vent (cont'd) -

2-R16) provide redundant back-up monitoring capabilities to the R41C monitors.

Radioiodine and particulate sampling capabilities are provided by charcoal cartridge and filter medium samplers with redundant back-up sampling capabilities provided by R41B and R41A, respectively. Plant Vent flow rate is measured and as a back-up may be determined empirically as a function of fan operation (fan curves). Sampler flow rates are determined by flow rate instrumentation (e.g., venturi rotometer).

A gaseous radioactive waste flow diagrams with the applicable, associated radiation monitoring instrumentation and controls are presented as Figures 2-1 and 2-2 for Units_ 1 and 2, respectively.

16

Salem ODCM Rev. 5 12/21/88 2.2 Gaseous Effluent Monitor Setpoint Determination 2.2.1 Containment and Plant Vent Monitor.

Per the requirements of Technical Specification 3.3.3.9, alarm setpoints shall be established for the gaseous effluent monitoring instrumentation to ensure that the release rate of noble gases does not exceed the limits of Specification 3*.11.2.1, which corresponds to a dose rate at the SITE BOUNDARY of 500 mrem/year to the total body or 3000 mrem/year to the skin.

Based on a grab sample analysis of the applicable release (i.e., grab sample of the Containment atmosphere, waste gas decay tank, or Plant Vent), the radiation monitoring alarm setpoints may be established by the following calculation method.

The measured radionuclide concentrations and release rate are used to calcui"ate the fraction of the allowable release rate, as limited by Specification 3.11.2.1, by the equation:

FRAC = [4.72E+02

  • X/Q *VF*

~ (Ci* Ki)]/ 500

( 2.1)

FRAC = [4.72E+02

  • X/Q *VF*~ (Ci* (Li+ 1.1 Mi))] / 3000 (2.2) where:

FRAC X/Q VF C*

l K*

l L*

l

=

=

=

=

=

=

fraction of the allowable release rate based on the identified radionuclide concenrations an~ the release flow rate annual average meteorological dispersion to the controlling site boundary location (sec/m3)

  • ventilation system flow rate for the applicable release point and monitor (ft3/min) concentration of noble gas radionuclide i as determined by radioanalysis of grab sample (uCi/cm3 )

total body dose conversion factor for noble gas radionuclide i (mrem/yr per uCi/m3 from Table 2-1) beta skin dose conversion factor for noble gas radionuclide i (mrem/yr per uci/m3 from Table 2-1) 17

Salem ODCM Rev. 5 12/21/88 M* l

= gamma air dose conversion factor for noble gas radionuclide i (mrem/yr per uCi/m3 from Table 2-1) 1.1

= mrem skin dose per mrad gamma air dose (mrem/mrad) 500

= total body dose rate limit (mrem/yr) 3000 = skin dose rate limit (mrem/yr) 4.72E+02

=

conversion factor (cm3/ft3

  • min/sec)

Based on the more limiting FRAC (i.e., higher value) as determined above, the alarm setpoints for the applicable monitors (R16, R41C, and/or R12A) may be calculated by the equation:

SP = [AF * ~ Ci

  • SEN / FRAC] + bkg (2.3) where:

SP SEN bkg AF

= alarm setpoint corresponding to the maximum allowable release rate (cpm)

= monitor sensitivity (cpm per uCi/cm3)

= background of the monitor (cpm)

= administrative allocation factor for the specific monitor and type release, which corresponds to the fraction of the total allowable release rate that is administratively allocated to the release.

The allocation factor (AF) is an administrative control imposed to ensure that combined releases from Salem Units 1 and 2 and Hope Creek will not exceed the regulatory limits on release rate from the site (i.e., the release rate limits of Technical Specification 3.11.2.1).

Normally, the combined AF value for Salem Units 1 and 2 is 0.5 (0.25 per unit), with the remainder 0.5 allocated to Hope Creek.

Any increase in AF above 0.5 for the Salem Nuclear Generating Station will be coordinated with the Hope Creek Generating Station to ensure that the combined allocation factors for all units do not exceed 1.0.

18

Salem ODCM Rev. 5 12/21/88 2.2.2 Conservative Default Values.

A conservative alarm setpoint can be established, in lieu of the individual radionuclide evaluation based on the grab sample analysis, to eliminate the potential of periodically having to adjust the setpoint to reflect minor changes in radionuclide distribution and variations in release flow rate.

The alarm setpoint may be conservatively determined by the default values presented in Table 2-2 and 2-3 for Units 1 and 2, respectively.

These values are base9 upon:

the maximum ventilation (or purge) flow rate; a radionuclide distribution* comprised of 95% Xe-133, 2%

Xe-135, 1% Xe-133m, 1% Kr-88 and 1% Kr-85; and an administrative allocation factor of 0.25 to conservatively ensure that any simultaneous releases from Salem Units 1 and 2 do not exceed the maximum allowable release rate.

For this radionuclide distribution, the alarm setpoint based on the total body dose rate is more restrictive than the corresponding setpoint based on the skin dose rate.

The resulting conservative, default setpoints are presented in Tables 2-2 and 2-3.

I Adopted from ANSI N237-1976/ANS-18.1, Source Term Specifications, Tab 19

Salem ODCM Rev. 5 12/21/88 2.3 Gaseous Effluent Instantaneous Dose Rate Calculations -

10 CFR 20 2.3.1 Site Boundary Dose Rate -

Noble Gases. Technical Specification 3.11.2.la limits the dose rate at the SITE BOUNDARY due to noble gas releases to ~500 mrem/yr, total body and ~3000 mrem/yr, skin.

Radiation monitor alarm setpoints are established to ensure that these release limits are not exceeded.

In the event any gaseous releases from the station results in an alarm setpoint being exceeded, an evaluation of the SITE BOUNDARY dose rate resulting from the release may be performed using the following equations:

(2.4) and Ds = X/Q *

(2.5) where:

Dtb Ds X/Q Qi K* 1 L*

1 M* 1 1.1

=

=

=

=

=

=

total body dose rate (mrem/yr) skin dose rate (mrem/yr) atmospheric dispersion to the controlling SITE BOUNDARY location (sec/m3 )

average release rate of radionuclide i over the release period under evaluation (uCi/sec) total body dose conversion factor for noble gas radionuclide i (mrem/yr per uCi/m3, from Table 2-1) beta skin dose conversion factor for noble gas radionuclide i (mrem/yr per uCi/m3, from Table 2-1) gamma air dose conversion factor for noble gas radionuclide i (mrad/yr per uCi/m3, from Table 2-1) mrem skin dose per mrad gamma air dose (mrem/mrad)

As appropriate, simultaneous releases from Salem Units 1 and 2 and Hope creek will be considered in evaluating compliance with the release rate limits of Specification 3.11.2.la, following any release exceeding the above prescribed alarm setpoints.

Monitor 20

Salem ODCM Rev. 5 12/21/88 indications (readings) may be averaged over a time period not to exceed 15 minutes when determining noble gas release rate based on correlation of the monitor reading and monitor sensitivity.

The 15 minute averaging is needed to allow for reasonable monitor response to potentially_ changing radioactive material concentrations and to exclude potential electronic spikes in monitor readings that may be unrelated to radioactive material releases.

As identified, any electronic spiking monitor responses may be excluded from the analysis.

NOTE:

For administrative purposes, more conservative alarm setpoints than those as prescribed above may be imposed.

However, conditions exceeding these more limiting alarm setpoints do not necessarily indicate radioactive material release rates exceeding the limits of Technical Specification 3.11.2.la.

Provided actual releases do not result in radiation monitor indications exceeding alarm setpoint values based on the above criteria, no further analyses are required for demonstrating compliance with the limits of Specification 3.11.2.la.

Actual meteorological conditions concurrent with the release period or the default, annual average dispersion parameters as presented in Table 2-4 may be used for evaluating the gaseous effluent dose rate.

2.3.2 Site Boundary Dose Rate - Radioiodine and Particulates.

Technical Specification 3.11.2.1.b limits the dose rate to 51500 mrem/yr to any organ for I-131, tritium and particulates with half-lives greater than 8 days. To demonstrate compliance with this limit, an evaluation is performed at a frequency no greater than that corresponding to the sampling and analysis time period 21

Salem ODCM R~v. 5 12/21/88 (e.g., nominally once per 7 days).

The following equation may be used for the dose rate evaluation:

where:

Do

=

X/Q =

R*

=

].

Qi

=

._)

( 2. 6)

(

average organ dose rate over the sampling time period (mrem/yr) atmospheric dispersion to the controlling SITE BOUNDARY location for the inhalation pathway (sec/m3 )

dose ~arameter for radionuclide i, (mrem/yr per uci/m ) for the child inhalation pathway from Table 2-5 average release rate over the appropriate sampling period and analysis frequency for radionuclide i --

I-131, I-133, tritium or other radionuclide in particulate form with half-life greater than 8 days (uCi/sec)

By substituting 1500 mrem/yr for Do and solving for Q, an allowable release rate for I-131 can be determined.

Based on the annual average meteorological dispersion (see Table 2-4) and the most limiting potential pathway, age group and organ (inhalation, child, thyroid -- Ri = 1.62E+07 mrem/yr per uci/m3), the allowable release rate for I-131 is 42 uci/sec.

Reducing this

  • release rate by a factor of 4 to account for potential dose contributions from other radioactive particulate material and other release points (e.g., Hope Creek), the corresponding release rate allocated to each of the Salem units is 10.5 uci/sec.

For a 7 day period, which is the nominal sampling and analysis frequency for I-13*1, the cumulative release is 6. 3 Ci.

Therefore, as long as the I-131 releases in any 7 day period do not exceed 6.3 Ci, no additional analyses are needed for verifying compliance with the Technical Specification 3.11.2.1.b limits on allowable release rate.

22

Salem ODCM Rev. 5 12/21/88 2.4 Noble Gas Effluent Dose Calculations -

10 CFR 50 2.4.1 UNRESTRICTED AREA Dose - Noble Gases.

Technical Specification 3.11.2.2 requires a periodic assessment of releases of noble gases to evaluate compliance with the quarterly dose limits of 55 mrad, gamma-air and <10 mrad, beta-air and the calendar year limits 510 mrad, gamma-air and 520 mrad, beta-air.

The limits are applicable separately to each unit and are not combined site limits.

The following equations may be used to calculate the gamma-air and beta-air doses:

=

3.17E-08

  • X/Q *

~ (Mi

  • Qi) and

=

3.17E-08

  • X/Q *

~ (Ni

  • Qi) where:

Dg

= air dose due to gamma emissions for noble gas radionuclides (mrad)

Db

= air dose due to beta emissions for noble gas radionuclides (mrad)

X/Q = atmospheric dispersion to the controlling SITE BOUNDARY location ( sec/m3)

(2.7)

(2.8)'

Qi

= cumulative release of noble gas radionuclide.i over the period of interest (uCi)

Mi

= air dose factor due to gamma emissions from noble gas radionuclide i (mrad/yr per uCi/m3, from Table 2-1)

Ni = air dose factor due to beta emissions from noble gas radionuclide i (mrad/yr per uCi/m3, Table 2-1) 3.17E-08 = conversion factor (yr/sec) 2.4.2 Simplified Dose Calculation for Noble Gases.

In lieu of the individual noble gas radionuclide dose assessment as presented above, the following simplified dose calculation equations may be used for verifying compliance with the dose limits of Technical Specification 3.11.2.2.

(Refer to Appendix C 23

Salem ODCM Rev. 5 12/21/88 for the derivation and justification for this simplified method.)

=

=

where:

Mef f =

Neff =

Qi

=

0.50 =

3.17E-08


  • X/Q
  • Mef f * :E Qi (2.9) 0.50 and 3.17E-08

  • X/Q
  • Neff * :E Qi (2.10) 0.50 5.3E+02, effective gamma-air dose factor (mrad/yr per uCi/m3 )

1.1E+03, effective beta-air dose factor (mrad/yr per uCi/m3 )

cumulative release for all noble gas radionuclides (uCi) conservatism factor to account for potential variability in the radionuclide distribution Actual meteorological conditions concurrent with the release period or the default, annual average dispersion parameters as presented in Table 2-4, may be used for the evaluation of the gamma-air and beta-air doses.

24

_j

Salem ODCM Rev. 5 12/21/88 2.5 Radioiodine and Particulate Dose Calculations -

10 CFR 50 2.5.1 UNRESTRICTED AREA Dose - Radioiodine and Particulates.

In accordance with requirements of Technical Specification 3.11.2.3, a periodic assessment shall be performed to ev_aluate compliance with the quarterly dose limit of ~7.5 mrem and calendar year limit ~15 mrem to any organ.

The following equation may be used to evaluate the maximum organ dose due to releases of I-131, tritium and particulates with half-lives greater than 8 days:

=

where:

w R*

l.

SFp 3.17E-08

  • W
  • SFp * ~ (Ri
  • Qi)

(2.11)

=

dose or dose commitment via all pathways p and controlling age group a (as identified in Table 2-

4) to organ o, including the total body (mrem)

= atmospheric dispersion parameter to the controlling location(s) as identified in Table 2-4

~/Q = atmospheric dispersion for i~halation pathway and H-3 dose contribution via other pathways (sec/m3)

D/Q =

atmospheric deposition for vegetation, milk and ground plane exposure pathways (m-2 )

= dose factor for radionuclide i, (mrem/yr per uCi/m3) or (m2 - mrem/yr per uCi/sec) from Table 2-5 for each age group a and the applicable pathway p as identified in Table 2-4.

Values for Ri were derived in accordance with the methods described in NUREG- 0133.

= cumulative release over the period of interest for radionuclide i -- I-131 or radioactive material in particulate form with half-life greater than 8 days (uCi).

= annual seasonal correction factor to account for the fraction of the year that the applicable exposure pathway does not exist.

1)

For milk and vegetation exposure pathways:

=

A six month fresh vegetation and grazing season (May through October)

=

0.5

2)

For inhalation and ground plane exposure pathways:

=

1. 0 25 I

Salem ODCM Rev. 5 12/21/88 For evaluating the maximum exposed individual, the infant age group is controlling for the milk pathway and the child age group is controlling for the vegetation pathway.

Only the controlling age group and pathway as identified in Table 2-4 need be evaluated for compliance with Technical Specification 3.11.2.3.

2.5.2 Simplified* Dose Calculation for Radioiodines and Particulates.

In lieu of the individual radionuclide (I-131 and particulates) dose assessment as presented above, the following simplified dose calculation equation may be used for verifying compliance with the dose limits of Technical Specification 3.11.2.3 (refer to Appendix D for the derivation and justification of this simplified method).

=

where:

=

0max RI-131 =

=

=

=

3.17E-08

  • W
  • SFp
  • Rr-131
  • E Qi (2~12) maximum organ dose (mrem)

I-131 dose parameter for the thyroid for the identified controlling pathway 1.05E+12, infant thyroid dose parameter with the cow-milk pathway controlling (m2 - mrem/yr per uCi/sec)

D/Q for radioiodine, 2.lE-10 1/m2 cumulative release over the period of interest for radionuclide i -- I-131 or radiaoctive material in particulate from with half life greater than 8 days (uCi)

The location of exposure pathways and the maximum organ dose calculation may be based on the available pathways in the surrounding environment of Salem as identified by the annual

.land-use census (Technical Specification 3.12.2).

Otherwise, the dose will be evaluated based on the predetermined controlling pathways as identified in Table 2-4.

26 I

Salem ODCM Rev. 5 12/21/88 2.6 Secondary Side Radioactive Gaseous Effluents and Dose Calculations During periods of primary to secondary leakage, minor levels of radioactive material may be released via the secondary system to the atmosphere.

Non-condensables (e.g., noble gases) will be predominately released via the condenser evacuation system and will be monitored and quantified by the routine plant vent monitoring and sampling system and procedures (e.g., R15 on condenser evacuation, R41C on plant vent, and the plant vent particulate and charcoal samplers).

However, if the Steam Generator blowdown is routed directly to the Chemical Waste Basin (via the SG blowdown flash tank) instead of being recycled through the condenser, it may be desirable to account for the potential atmospheric releases of radioiodines and particulates from the flash tank vent (i.e., releases due to moisture carry over).

Since this pathway is not sampled or monitored, it is necessary to calculate potential releases.

Based on the guidance in NRC NUREG-0133, the releases of the radioiodines and particulates may be calculated by the equation:

=

where:

Qi C*

l Rsgb

=

=

=

C*

  • l the release rate of radionuclide, i, from the steam generator flash tank vent (uCi/sec) the concentration of radionuclide, i, in the secondary coolant water averaged over not more than one week (uCi/ml) the steam generator blowdown rate to the flash tank (ml/sec) 27

=

SQftv =

Salem ODCM Rev. 5 12/21/88 the fraction of blowdown flashed in the tank determined from a heat balance taken around the flash tank at the applicable reactor power level the measured steam quality in the flash tank vent; or an assumed value of 0.85, based on NUREG-0017.

Tritium releases via the steam flashing may also be quantified using the above equation with the assumption of a steam quality (SQftv> equal to o. Since the H-3 will be associated with the water molecules, it is not necessary to account for the moisture carry-over which is the transport media for the radioiodines and particulates.

Based on the design and operating conditions at Salem, the fraction of blowdown converted to steam (pft) is approximately 0.48.

The equation simplifies to the following:

(2.14)

For H-3, the simplified equation is:

(2.15)

Also during reactor shutdown operations with a radioactively contaminated secondary system, radioactive material may be released to the atmosphere via the atmospheric reliefs (PORV) and the safety reliefs on the main steam lines and via the steam driven auxiliary feed pump exhaust.

The evaluation of the radioactive material concentration in the steam relative to that in the steam generator water is based on the guidance of NUREG-0017, Revision 1.

The partitioning factors for the radioiodines is 0.01 and is 0.001 for all other particulate radioactive 28

Salem* ODCM Rev. 5 12/21/88 material.

The resulting equation for quantifying releases via the atmospheric steam releases is:

where:

0.13

( 2.16)

= release rate of radionuclide i via pathway j (uCi/sec)

= steam flow for release pathway j

= 450,000 lb/hr per PORV

= 800,000 lb/hr per safety relief valve

=

50,000 lb/hr for auxiliary feed pump exhaust

= partitioning factor, ratio of concentration in steam to that in the water in the steam generator

= 0.01 for radioiodines

= 0.005 for all other particulates

= 1.0 for H-3

=conversion factor -

[(hr*ml) / (sec*lb)]

Any significant releases of noble gases via the atmospheric steam releases can be quantified in accordance with the calculation methods of the Salem Emergency Plan Implementation Procedure.

Alternately, the quantification of the release rate and cumulative releases may be based on actual samples of main steam collected at the R46 sample locations.

The measured radionuclide concentration in the steam may be used for quantifying the noble gases, radioiodine and particulate releases.

Note: The expected mode of operation would be to isolate the effected steam generator, thereby reducing the potential releases during the shutdown/cooldown process.

Use of the above calculation methods should consider actual operating conditions and release mechanisms.

The calculated quantities of radioactive materials may be used as inputs to the equation (2.11) or (2.12) to calculate offsite 29

Salem ODCM Rev. 5 12/21/88 doses for demonstrating compliance with the Radiological Effluent Technical Specifications.

30

Salem ODCM Rev. 5 12/21/88 2.7 Gaseous Effluent Dose Projection Technical Specification 3.11.2.4 requires that the GASEOUS RADWASTE TREATMENT SYSTEM and VENTILATION EXHAUST TREATMENT SYSTEM be used to reduce radioactive material levels prior to discharge when projected doses exceed one-half the annual design objective rate in any calendar quarter, i.e., exceeding:

0.625 mrad/quarter, gamma air; 1.25 mrad/quarter, beta air; or 1.875 mrem/quarter, maximum organ.

The applicable gaseous processing systems for maintaining radioactive material releases ALARA are the Auxiliary Building normal ventilation system (filtration systems # 1,2 and 3) and the Waste Gas Decay Tanks as delineated in Figures 2-3'and 2-4.

Dose projections are performed at least once per 31 days by the,

following equations:

where:

~ =

Dg

=

Dbp

=

Db

=

0maxp

=

0max

=

d

=

91

=

3.0 Special

=

=

=

Dg * (91 I d)

Db * (91 I d)

Dmax * (91 I d)

(2.17)

(2.18)

(2.19) gamma air dose projection for current calendar quarter (mrad) gamma air dose to date for current calendar quarter as determined by Equation 2.7 or 2.9 (mrem) beta air dose projection for current calendar quarter (mrad) beta air dose to date for current calendar quarter as determined by Equation 2.8 or 2.10 (mrem) maximum organ dose projection for current calendar quarter (mrem) maximum organ dose to date for current calendar quarter as determined by Equation 2.11 or 2.12 (mrem) number of days to date in current calendar quarter number of days in a calendar quarter Dose Analyses 31

Salem ODCM Rev. 5 12/21/88 3.1 Doses Due To Activities Inside the SITE BOUNDARY In accordance with Technical Spe~ification 6.9.1.11, the Radioactive Effluent Release Report (RERR) submitted within 60 days after January 1 of.each year shall include an assessment of radiation doses from radioactive liquid and gaseous effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY.

There is one location on Artificial Island that is accessible to MEMBERS OF THE PUBLIC for activities unrelated to PSE&G operational and support activities.

This location is the Second Sun (visitor's center) located *near the contractors gate for the Salem Nuclear Generating Station.

The calculation methods as presented in Sections 2.4 and 2.5 may be used for determining the maximum potential dose to a MEMBER OF THE PUBLIC based on the parameters from Table 2-4 and 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> per visit per year.

The default value for the meteorological dispersion data as presented in Table 2-3 may be used if current year meteorology in unavailable at the time of NRC reporting.

However, a follow-up evaluation shall be performed when the data becomes available

  • 32

Salem ODCM Rev. 5 12/21/88 3.2 Total dose to MEMBERS OF THE PUBLIC -

40 CFR 190 The Radioactive Effluent Release Report (RERR) submitted within 60 days after January 1 of each year shall also include an assessment of the radiation dose to the likely most exposed MEMBER OF THE PUBLIC for reactor releases and other nearby uranium fuel cycle sources (including dose contributions from effluents and direct radiation from on-site sources).

For the likely most exposed MEMBER OF THE PUBLIC in the vicinity of Artificial Island, the sources of exposure need only consider the Salem Nuclear Generating Station and the Hope Creek Nuclear Generating Station:

No other fuel cycle facilities contribute to the MEMBER OF THE PUBLIC dose for the Artificial Island vicinity.

The dose contribution from the operation of Hope Creek Nuclear Generating Station will be estimated based on the methods as presented in the Hope Creek Offsite Dose Calculation Manual (HCGS ODCM).

As appropriate for demonstrating/evaluating compliance with the limits of Technical Specification 3.11.4 (40 CFR 190), the results of the environmental monitoring program may be used for providing data on actual measured levels of radioactive material in the actual pathways of exposure.

33

Salem ODCM Rev. 5 12/21/88 3.2.l Effluent Dose Calculations.

For purposes of implementing the surveillance requirements of Technical Specification 3/4.11*4 and the reporting requirements of 6.9.1.11 (RERR), dose calculations for the Salem Nuclear Generating Station may be performed using the calculation methods contained within this ODCM; the conservative controlling pathways and locations of Table 2-4 or the actual pathways and locations as identified by the land use census (Technical Specification 3/4.12.2) may be used.

Average annual meteorological dispersion parameters or meteorological conditions concurrent with the release period under evaluation may be used.

3.2.2 Direct Exposure Dose Determination.

Any potentially significant direct exposure contribution to off-site individual doses may be evaluated based on the results of the environmental measurements (e.g., TLD, ion chamber measurements) and/or by the use of a radiation transport and shielding calculation method.

Only during atypical conditions will there exist any potential for significant on-site sources at Salem that would yield potentially significant off-site doses (i.e., in excess of 1 mrem per year to a MEMBER OF THE PUBLIC), that would require detailed evaluation for demonstrating compliance with 40 CFR 190.

However, should a situation exist whereby the direct exposure contribution is potentially significant, on-site measurements, off-site measurements and/or calculation techniques will be used for determination of dose for assessing 40 CFR 190 compliance.

4.0 Radiological Environmental Monitoring Program 34

Salem ODCM Rev. 5 12/21/88 4.1 Sampling Program The operational phase of the Radiological Environmental Monitoring Program (REMP) is conducted in accordance with the requirements of Appendix A Technical Specification 3.12.

The objectives of the program are:

To determine whether any significant increases occur in the concentration of radionuclides in the critical pathways of exposure in the vicinity of Artificial Island; To determine if the operation of the Salem Nuclear Generating Stations has resulted in any increase in the inventory of long lived radionuclides in the environment; To detect any changes in the ambient ga:mma radiation levels; and To verify that SNGS operations have no detrimental effects on the health and safety of the public or on the environment.

The sampling requirements (type of samples, collection frequency and analysis) and sample locations are presented in Appendix E.

35

Salem ODCM Rev. 5 12/21/88 4.2 Interlaboratory Comparison Program Technical Specification 3.12.3 requires-analyses be performed on radioactive material supplied as part of an Interlaboratory Comparison.

Participation in an approved Interlaboratory Comparison Program provides a check on the preciseness of measurements of radioactive materials in environmental samples.

A summary of the Interlaboratory Comparison Program results will be provided in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 6.9.1.10.

36

LETOOWN HX HIXED BED OEH I NEAALI ZEA TO HOLD-UP TANKS VOLUHE CONTROL TANK

~

J'"'

SAIWLING IASTE HONITOR SYSTEH HOLD-UP TANX fl SAHPLE LINES A

HO l

STEAH GENERATOR 19 IT]

NITOAS I

STEAH GENERATORS 111.12.13.14 STEAH GENERATOR BLOIOOIN LINES COHPONENT COOLING SURGE-TANK IASTE HOLD-UP TANK Ill STE AH GENERATOR BLOIOOIN TANK NON-ARO LIQUID WASTE DISPOSAL r

A37,,

RADIATION MONITORING LIQUID RELEASES UNIT l FIGURE 1-1 fl REACTOR COOLANT DARIN TANK J"'

REFUELING fl SPENT FUEL Ill HOLD-UP WATER STORAGE I+--

PIT TANK TANK OEH I NEARLZEA IASTE HON ITOR

  • TAN( Ill r

111 IASTE HOLD-UP NQ. I IASTE IASTE IUllTOR EVAPORATOR TANK fl2 EVAPORATOR I--+

TANK 112 FEED 100 EXCHANGER NQ. I GAS STRIPPER

(!] RIB TO CIRCULATING WATER SYSTEM __J OE LAI RAE A I VEA I

FROM VOL. CONTROL TANK VENT TO GASEOUS J"'

J'"

fl2 HOLD-UP fl3 HOLD-UP TANK TANK 1

114 fl2 113 EVAPORATOR EVAPORATOR EVAPORATOR FEED ION FEED 100 -

FEED ION EXCHANGER EXClfiffiEA EXCHANGER SALEH OOCH

<FOR I NFOA11AT ION ONL YI

R H

LETOOIN HX MIXED BED OEMINERAL!ZEA

~

TO HOLD-UP TANKS VDLUHE CONTROL TANK J-SAl1PLING IASTE HON !TOR SYSTEH HDLO-lJ> TANK 12 l

STEAM GENERATOR SAllPLE LINES 19

[!]

ONITOAS I

STEAH GENERATORS 121.22.23.24 STEAM GENERATOR BLOIOOIN LINES COMPONENT CODLING SURGE-TANK IRSTE HOLD-UP TRNK 121 STEA11 GENERATOR BLDIDDIN TANK NON-RAO LIDU!O WASTE DISPOSAL r

R37 r1

  • L....J RADIATION MONITORING LIQUID RELEASES UNIT 2 FIGURE 1-2 12 REACTOR COOLANT DAR 1 N I

FROH VOL. CONTROL TANK TANK VENT TO GASEOUS Lr Lr J"

REFUELING 12 SPENT FUEL 121 HDLD-lJ>

122 HOLD-UP 123 HOLD-UP IATEA STORAGE I+--

PIT TANK TANK TANK TANK OEM 1 NERALZEA IASTE HDNITOR TANI( Ill r

1 121 124 122 123 IRSTE HOLD-Ii' NQ. 2 IRSTE IASTE IQ !TOR EVRPORRTOR EVAPORATOR EVAPORATOR EVAPORATOR TAii( 122 EVAPORATOR

~ TAii( 122 FEED ION 14--

FEED ION FEED l()l I+---

FEED !ON EXCHANGER EXCHRNGER EXCHANGER EXCHANGER NQ. 2 GAS STRIPPER SALEH OOCH

!FOR !NFOAHAT!ON ONLY>

[!] Rl8 TO CIRCULATING IATEA SYSTEH ~

DELAWARE RIVER

-HUf OTHER UNIT Wl.111 1 VVMf Wl.43 WI. 811 I IDIFAOM OTHER UNIT WASTEEVAP FEED PUMP FROM LAUNDRY I CHEM TKS Wl.1111 Wl.172 FROM BAEVAP Wl.10 I

I I

1 WHUT WI.II 2WHUT WMlfJT Wl.119 Wl.11 2UNIT WHUTS Wl.71 Wl.13 WASTEEVAP:

I I

E001PDAS AUX lllllG SUMP Tll FlCXJADRS C\\CS HUI RELIEFS RttRSUMPS AWPP Wl.222 AWST Wi.100 CVCSHUT DA Wl.13 Wl.12 Wl.15 Wl.19 COHTSUMP Wl.1111 1'

2Wl114 2Wll93 WI.I ACPHf AD Tll9 RC LOOP DAS AXflAHGELO ACCIJMULATOR DRS Ellt:ESS LET DOWN RCDT ACPS 3SEAl.LO Wl.41


+--------+------.+---w-.+--N-r~.q-~-t.-~.........

WLlllA

~

I r-""~~l--~!---t.1~~~~~j_~_.!!....~.C)G~-4)Ct--~.()1WMtiUT i

ru-

~

<ft IWl.lllO 2Wl-I I

wi.1113 I

I I

I L-----

Wl.115 TOANDFAOM IWUllll OTHER UNIT T-----w--* 2WMHUT 4-1 2Wl911 1' IWI.-

IWl.1114 IWRllO,-+-- - - -0C> - -+-- -OC...,...-::.,.--..---00---+-

... -+-- - -M-+;

  • Ion fi. o~.:** >~w*

[;~:::*

~

XWR2B

._r--T:J

  • -1 *WA2' OllERBOoVID ORWMTS 2l.W18 -

II WASTE EVAP Wl.183

e. e..

21 CtllC WATER DISCH L------1--.J LWI~

ILW41 WI.II Wl.11 Wl.11 Wl.ITll 2WMHUT ruMP FOR INFORMATION ONL~

FIGURE 1-3 LIQUID WASTE

Salem ODCM Rev. 5 12/21/88 Table 1-1 Parameters for Liquid Alarm Setpoint Determinations Unit 1 Parameter MP Ce MPCI-131 Ci MPCi SEN 1-R18 Actual Value calculated 3E-07 measured as determined as determined 1-R19 (A,B,C,D)

C\\.I 1-R13 (A,B,C,D,E) as determined RR 1-R18 as determined 1-R19 1-R13 Default Value 1E-05

  • N/A N/A N/A 2.9E+07 2.9E+07 1.2E+08 1.85E+05 120 120 2500 Units uCi/ml uCi/ml uCi/ml uCi/ml Corrments calculated for each batch to be released I-131 MPC conservatively used for SG blow-down and Service Water monitor setpoints taken from garrma spectral analysis of liquid effluent taken from 10 CFR 20, Appendix B, Table II, Col. 2.

cpm per uCi/ml radwaste effluent (Cs-137) gpm gpm Steam Generator blowdown (Cs-137)

Service Water - Containment fan cooling

  • ccs-137)

Circulating Water System, single CW pump determined prior to release; release rate can be adjusted for Technical Specification compliance Steam Generator blowdown ra~e per generator Service Water flow rate for Containment fan coolers SP 1-R18 calculated 4.4E+05C+bkg) cpm Default alarm setpoints; more conservative values may be used as deemed appropriate and desirable for ensuring regulatory compliance and for maintaining releases ALARA.

1-R19** calculated 1.3E+04(+bkg) 1-R13** calculated 2.6E+03(+bkg)

Refer to Appendix A for derivation The MPC values of I-131 C3E-07 uCi/ml) has been used for derivation of the R19 Steam Generator blowdown and R13 Service Water monitor setpoints as discussed in Section 1.2.2

  • 40

Parameter Actual Value MP Ce calculated MPCI-131 3E-07 Ci measured MPCi as determined SEN 2-R18 as determined 2-R19 (A,B,C,D) 2-R13 (A,B,C)

R37 cw as determined RR 2-R18 as determined 2-R19

. 2-R13 R37 SP 2-R18 calculated 2-R19** calculated 2-R13** calculated R37**** calculated Salem ODCM Rev. 5 12/21/88 Table 1-2 Parameters for Liquid Alarm Setpoint Determinations Unit 2 Default Units Conmen ts Value 1E-05

  • uCi/ml calculate for each batch to be released N/A uCi/ml I-131 MPC conservatively used for SG blow-down, Service Water and Chemical Waste Basin monitor setpoints N/A uCi/ml taken from ganma spectral analysis of liquid effluent N/A uCi/ml taken from 10 CFR 20, Appendix B, Table I I, Col. 2.

8.8E+07 cpm per uCi/ml radwaste effluent (Cs-137) 8.8E+07 8.8E+07 8.8E+07 1.85E+05 120 120 2500 300 8.0E+OSC+bkg) 3.9E+04(+bkg) 8.8E+02C+bkg) 1.6E+04(+bkg) gpm.

gpm cpm Steam Generator blowdown (Cs-137)

Service Water - Containment fan cooling (Cs-137)

Chemical Waste Basin (Cs-137)

Circulating Water System, single CW punp (Note no CW punp in service for 2R13 monitor see section 1.2.2) determined prior to release; release rate can be adjusted for Technical* Specification compliance Steam Generator blowdown rate per generator Service water flow rate for Containment fan coolers Chemical waste Basin discharge Default alarm setpoints; more conservative values may be used as deemed appropriate and desirable for ensuring regulatory compliance and for maintaining releases ALARA.

Refer to Appendix A for derivation Based on Cs-137 response

      • Actual calculated setpoint for 2-R18 (1.3E+06) is greater than the full scale monitor indicator, therefore, for consrvatism the reconmended setpoint has been reduced to 3.0E+OS cpm
        • The MPC value of I-131 (3E-07 uCi/ml) has been used for derivation of the R19 Steam generator blowdown and the R37 Chemical Waste Basin monitor setpoints as discussed in Section 1.2.2 41

Salem ODCM Rev. 5 12/21/88 Table 1-3 Site Related Ingestion Dose Commitment Factors, Aio

~mrem/hr per uCi/ml)

Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI H-3 2.82E-l 2.82E-l 2.82E-l 2.82E-1 2.82E-1 2.82E-l C-14 1~45E+4 2.90E+3 2.90E+3 2.90E+3 2.90E+3 2.90E+3 2.90E+3 Na-24 4.57E-l 4.57E-1 4.57E-l 4.57E-l 4.57E-l 4.57E-l 4.57E-l P-32 4.69E+6 2.91E+5

1. 81E+5 5.27E+5 Cr-51 5.58E+O 3.34E+O
1. 23E+O 7.40E+O l.40E+3 Mn-54 7.06E+3
1. 35E+3 2.10E+3 2.16E+4 Mn-56
1. 78E+2 3.15E+l 2.26E+2 I

5.67E+3 Fe-55 5.11E+4 3.53E+4 8.23E+3

1. 97E+4 2.03E+4 Fe-59 8.06E+4
1. 90E+5 7.27E+4 5.30E+4 6.32E+5 Co-57
1. 42E+2 2.36E+2 3.59E+3 Co-58 6.03E+2 l.35E+3
1. 22E+4 Co-60
1. 73E+3 3.82E+3 3.25E+4 Ni-63 4.96E+4 3.44E+3 l.67E+3 7.18E+2 Ni-65 2.02E+2 2.62E+l
1. 20E+l 6.65E+2 cu-64 2.14E+2
1. 01E+2 5.40E+2 1.83E+4 Zn-65
1. 61E+5 5.13E+5 2.32E+5 3.43E+5 3.23E+5 Zn-69 3.43E+2 6.56E+2 4.56E+l 4.26E+2 9.85E+l Br-82 4.07E+O 4.67E+O Br-83 7.25E-2 l.04E-l Br-84 9.39E-2 7.37E-7 Br-85 3.86E-3 Rb-86 6.24E+2 2.91E+2
1. 23E+2 Rb-88
1. 79E+O 9.49E-1 2.47E-ll Rb-89 l.19E+O 8.34E-l 6.89E-14 Sr-89 4.99E+3
1. 43E+2 8.00E+2 Sr-90
1. 23E+5 3.01E+4 3.55E+3 Sr-91 9.18E+l 3.71E+O 4.37E+2 Sr-92 3.48E+l
1. 51E+O 6.90E+2 Y-90 6.06E+O l.63E-l 6.42E+4 Y-9lm 5.73E-2 2.22E-3 l.68E-l Y-91 8.88E+l 2.37E+O 4.89E+4 Y-.92 5.32E-l l.56E-2 9.32E+3 Y-93 l.69E+O 4.66E-2 5.35E+4 Zr-95
1. 59E+l 5.llE+O 3.46E+O 8.02E+O l.62E+4 Zr-97 8.81E-l l.78E-l 8.13E-2 2.68E-l 5.51E+4 Nb-95 4.47E+2 2.49E+2
1. 34E+2 2.46E+2
1. 51E+6 Nb-97 3.75E+O 9.49E-l 3.46E-l
1. llE+O 3.50E+3 Mo-99
1. 28E+2 2.43E+l 2.89E+2 2.96E+2 Tc-99m
1. 30E-2 3.66E-2 4.66E-l 5.56E-l 1.79E-2 2.17E+l Tc-101
1. 33E-2 l.92E-2
1. 88E-l 3.46E-1 9.81E-3 5.77E-14 42

Salem ODCM Rev. 5 12/21/88 Table 1-3 (cont'd) site Related Ingestion Dose Commitment Factors, Aio (mrem/hr per uCi/ml)

Nuclide Bone Liver T.Body Thyroid Kidney Lung GI-LLI Ru-103 1.07E+2 4.60E+l 4.07E+2

1. 25E+4 Ru-105 8.89E+O 3.51E+O 1.15E+2 5.44E+3 Ru-106 1.59E+3 2.01E+2 3.06E+3
1. 03E+5 Rh-103m Rh-106 Ag-llOm
1. 56E+3
1. 45E+3 8.60E+2 2.85E+3 5.91E+5 Sb-124 2.77E+2 5.23E+O 1.10E+2. 6.71E-1 2.15E+2 7.86E+3 Sb-125 1.77E+2
1. 98E+O 4.21E+l
1. 80E-1 1.36E+2
1. 95E+3 Te-125m 2.17E+2 7.86E+l 2.91E+l 6.52E+l 8.82E+2 8.66E+2 Te-127m 5.48E+2 l.96E+2 6.68E+l
1. 40E+2 2.23E+3 1.84E+3 Te-127 8.90E+O 3.20E+O
1. 93E+O 6.60E+O 3.63E+l 7.03E+2 Te-129m 9.31E+2 3.47E+2
1. 47E+2 3.20E+2 3.89E+3 4.69E+3 Te-129 2.54E+O 9.55E-1 6.19E-1
1. 95E+O 1.07E+l 1.92E+O Te-131m
1. 40E+2 6.85E+l 5.71E+l 1.08E+2 6.94E+2 6.80E+3 Te-131
  • 1.59E+O 6.66E-l 5.03E-1
1. 31E+O 6.99E+O 2.26E-1 Te-132 2.04E+2
1. 32E+2
1. 24E+2 1.46E+2
1. 27E+3
  • 6.24E+3 I-130 3.96E+l 1.17E+2 4.61E+l 9.91E+3
1. 82E+2
1. 01E+2 I-131 2.18E+2 3.12E+2 1.79E+2 l.02E+5 5.;35E+2 8.23E+l I~132 1.06E+l 2.85E+l 9.96E+O 9.96E+2 4.54E+l 5.35E+O I-133 7.45E+l
1. 30E+2 3.95E+l 1.90E+4 2.26E+2 1.16E+2 I-134 5.56E+O 1.51E+l 5.40E+O 2.62E+2 2.40E+l
1. 32E-2 I-135 2.32E+l 6.08E+l 2.24E+l 4.01E+3 9.75E+l 6.87E+l Cs-134 6.84E+3 L 63E+4
1. 33E+4 5.27E+3 1.75E+3 2.85E+2 Cs-136 7.16E+2 2.83E+3 2.04E+3
1. 57E+3 2.16E+2 3.21E+2 Cs-137 8.77E+3
1. 20E+4 7.85E+3 4.07E+3
1. 35E+3 2.32E+2 Cs-138 6.07E+O
1. 20E+l 5.94E+O 8.81E+O 8.70E-1 5.12E-5 Ba-139 7.85E+O 5.59E-3 2.30E-1 5.23E-3 3.17E-3
1. 39E+l Ba-140 1.64E+3 2.06E+O l.08E+2 7.02E-1 1.18E+O 3.38E+3 Ba-141 3.81E+O 2.88E-3
1. 29E-1 2.68E-3 1.63E-3 l.80E-9 Ba-142 1.72E+O 1.77E-3 1.0SE-1
1. 50E-3 l.OOE-3 2.43E-18 La-140
1. 57E+O *7.94E-1 2.lOE-1 5.83E+4 La-142 8.06E-2 3.67E-2 9.13E-3 2.68E+2 Ce-141 3.43E+O 2.32E+O 2.63E-1 1.08E+O 8.86E+3 Ce-143 6.04E-1 4.46E+2 4.94E-2 1.97E-1
1. 67E+4 Ce-144 1.79E+2 7.47E+l 9.59E+O 4.43E+l 6.04E+4 Pr-143 5.79E+O 2.32E+O 2.87E-1 1.34E+O 2.54E+4 Pr-144
1. 90E-2 7.87E-3 9.64E-4 4.44E-3 2.73E-9 Nd-147 3.96E+O 4.58E+O 2.74E-1 2.68E+O 2.20E+4 W-187 9.16E+O 7.66E+O 2.68E+O 2.51E+3 Np-239 3.53E-2 3.47E-3 1.91E-3
1. 08E-2 7.11E+2 43

Salem ODCM Rev. 5 12/21/88 Table 1-4 Bioaccumulation Factors (BFi)

(pCi/kg per pCi/liter)*

Element Saltwater Fish Saltwater Invertebrate H

9.0E-01

9. 3E--Ol c
1. 8E+03
1. 4E+03 Na 6.7E-02 1.9E-Ol p

3.0E+03 3.0E+04 Cr 4.0E+02 2.0E+03 Mn 5.5E+02 4.0E+02 Fe 3.0E+03

. 2.0E+04 Co 1.0E+02

1. OE+03 Ni l.OE+02 2.5E+02 Cu 6.7E+02
1. 7E+03 Zn 2.0E+03 5.0E+04 Br 1.5E-02 3.lE+OO Rb 8.3E+OO
1. 7E+Ol Sr 2.0E+OO 2.0E+Ol y

2.5E+Ol

1. OE+03 Zr 2.0E+02 8.0E+Ol Nb 3.0E+04 1.0E+02 Mo
1. OE+Ol
1. OE+Ol Tc
1. OE+Ol 5.0E+Ol Ru 3.0E+OO
1. OE+03 Rh
1. OE+Ol 2.0E+03 Ag 3.3E+03 3.3E+03 Sb 4.0E+Ol 5.4E+OO Te
1. OE+Ol
1. OE+02 I
1. OE+Ol 5.0E+Ol Cs 4.0E+Ol 2.5E+Ol Ba 1.0E+Ol
1. OE+Ol La 2.5E+Ol 1.0E+03 Ce
1. OE+Ol 6.0E+02 Pr 2.5E+Ol l.OE+03 Nd 2.5E+Ol
1. OE+03
w.

3.0E+Ol 3.0E+Ol Np 1.0E+Ol

1. OE+Ol Values in this table are taken from Regulatory Guide 1.109 except for phosphurus (fish) which is adapted from NUREG/CR-1336 and silver and antimony which are taken from UCRL 50564, Rev. 1, October 1972.

44

_1:_111111 __,,..,. _____ -----

M 8 U>>IWNMfNJ a1 ~

.. a>RESIM. IA&E.

lllDA~ Pl~~:-Ot

--~~~-0~

-~

a>>t~N1

M CONl..... NI NRANif

~*

RDIM M4ll4 -

Mlllll llAU41 RAUi>

fM 101'3 RAIOIM OtAHHEL PSEIOCO COW'tJfEA

__I.IL_...JllUH..lllL

_..1JL.__

MIC MIOISS llA2UI

==----... -*

MIC MIO RAolCM AAHm M4111 AUX lkOO ROOf r,;;..-""~---,

I HflfASl.

..r.-.i I

~

..°'l'.!"I:_i-

~i Pl.AHi VIN18 2 >

r.;;:; - -- ---,

I -...l::""... ~I

'------=:El

~

LI PROCESS RADIATION r.1'1 MONJTOR

&.j AREA RADIATION MONJTOR

-+-GASEOUS EFFLUENT


ELECTRICAL MID-

--- PIEUMATIC r- - --- - --

~

~~*

I I

-i- --t- _J l ~-*-t.. -~b I

I 1

  • CllNfROL~~*!f~

_ __J

,.- ~-:..

r.!11..

~-

FUEL SroRAGE

~*

~""""ClftlfUlll _J fUEl.wo..m llUllOINO I

WGtl I l~fROMGASOECAT~-51----~

FOR INFORMATION ONLY FIGURE 2-1 RADIATION MONITORING GASEOUS 1UNIT

.. ~....-"'

., ~

~SEA&. JA&f

... ~

11:,..._.l HiU'OI R m-o-

-~

P!,....._ HGt>t b. tJD'G'"

-~-

-t -~!'!.tt_!'_

t-----

......... 11.00

...1111!111&..

,.,om

.MllUll.

MUii MQIJ MOii RA.Qt*

PBllGCIO

.A-..A'llllJlll.

ftA-1

.. u...

MIOlll MIOIM MtC MIOlll MIC M-MCUI MIC~ -

Ali:::.-DG~

'tAi*

YAAO I

~---~ _J ii!!!,.,

~I L...--------'

~

.. --~

L._ ___ _

r 1

MSC

"°-

~

PROCESS RADIATION MONITOR

~

AREA RADIA110N MONITOR

-+GASEOUS EFR.lJENT


El.ECTRICAL

--- PNEUMATIC c-t:_-~-r

,----lru::-

I 1..:.__~

-2".!"~'!." __J I

..... OAS........... SYSJfW I

IPSOIAAOI" FR(.. GAS DECA'f IN9SI I

.......... y

~

~-~~~-

I FOR INFORMATION ONLY FIGURE 2-2 RADIATION MONITORING GASEOUS 2UNIT

Salem ODCM Rev. 5 12/21/88 Table 2-1 Dose Factors for Noble Gases Total Body Ganma Air Beta Air Dose Factor Skin Dose Factor Dose Factor Dose Factor Radionuclide Ki Li Mi Ni (mrem/yr per uCi/m3)

Cmrem/yr per uCi/m3)

Cmrad/yr per uCi/m3)

Cmrad/yr per uCi/m3)

Kr-83m 7.56E-02 1.93E+01 2.88E+02 Kr-85m 1.17E+03 1.46E+03 1.23E+03 1.97E+03 Kr*85 1.61E+01 1.34E+03 1.nE+01 1.95E+03 Kr*87 5.92E+03 9.73E+03 6.17E+03 1.03E!+-04 Kr-88 1.47E+04 2.37E+03 1.52E+04 2.93E+03 Kr-89 1.66E+04 1.01E+04 1.73E+04 1.06E+04 Kr-90 1.56E+04 7.29E+03 1.63E+04 7.83E+03 Xe-131m 9.15E+01 4.76E+02 1.56E+02 1.11E+03 Xe-133m 2.51E+02 9.94E+02 3.27E+02 1.48E+03 Xe-133 2.94E+02 3.06E+02 3.53E+02 1.05E+03 Xe-135m 3.12E+03 7.11E+02 3.36E+03 7.39E+02 Xe-135 1.81E+03 1.86E+03 1.92E+03 2.46E+03 Xe-137 1.42E+03 1.22E+04 1.51E+03 1.27E+04 Xe-138 8.83E+03 4.13E+03.

9.21E+03 4.75E+03 Ar-41 8.84E+03 2.69E+03 9.30E+03 3.28E+03 47

Parameter Actual Value X/Q calculated VF as measured (Plant or Vent) fan curves VF as measured (Cont.

or Purge) fan curves AF coordinated with HCGS Ci measured Ki nuclide specific Li nuclide specific Mi nuclide specific SEN 1-R41C*

as determined 1-R16 1-R12A SP 1-R41C calculated 1-R16 calculated 1-R12A** calculated Salem ODCM Rev. 5 12/21/88 Table 2-2 Parameters for Gaseous Alarm Setpoint Determinations Unit-1 Default Units Value 2.2E-06 sec/m3 1.25E+05 ft3/min 3.5E+04 0.25 unit less N/A uCi/cm3 N/A mrem/yr per uCitm3 N/A mrem/yr per uCi/m3 N/A mrad/yr per uCitm3 1.6E+07 cpm per uCi/cm3 3.6E+07 2.1E+06 3.3E+04(+bkg) cpm 7.4E+04(+bkg) 1.5E+04(+bkg)

COlllllents USNRC Salem Safety Evaluation, Sup. 3 Plant Vent - normal operation Containment purge Administrative allocation factor to ensure combined releases do not exceed release rate limit for site.

Values from Table 2-1 Values from Table 2-1 Values from Table 2-1 Plant Vent Plant Vent (redundant)

Containment Default alarm setpoints; more conservative values may be used as deemed appropriate and desirable for ensuring regulatory compliance and for maintaining releases ALARA.

Based on mean for calibration with mixture of radionuclides

    • Applicable during MODES 1 through 5. During MOOE 6 (refueling), monitor setpoint shall be reduced to 2X background in accordance with Tech Spec Table 3.3-6
  • 48

Salem ODCM Rev. 5 12/21/88 Table 2-3 Parameters for Gaseous Alarm Setpoint Determinations Unit-2 Parameter Actual Default Units Conmen ts Value Value X/Q calculated 2.2E-06 sectm3 Licensing technical specification value VF as measured 1.25E+05 ft3/min Plant Vent - normal operation (Plant or Vent) fan curves VF as measured 3.5E+04 ft3tmin Containment purge (Cont.

or Purge) fan curves AF coordinated 0.25 unitless Administrative allocation factor to with HCGS ensure coni>ined releases do not exceed release rate Limit for site.

Ci measured N/A uCi/cm3 Ki nuclide specific N/A mrem/yr per uci;m3 Values from Table 2-1 Li nuclide specific N/A mrem/yr per uCitm3 Values from Table 2-1 Mi nuclide specific N/A mrad/yr per uCi/m3 Values from Table 2-1 SEN 2-R41C*

as 1.6E+07 cpm per uCi/cm3 Plant Vent determined 2-R16 3.5E+Q7 Plant Vent (redundant) 2-R12A 3.3E+07 Containment SP 2-R41C calculated 3.3E+04(+bkg) cpm Default alarm setpoints; more conservative values may be used as deemed appropriate and 2-R16 calculated 7.2E+04(+bkg) desirable for ensuring regulatory compliance and for maintaining releases ALARA.

2-R12A** calculated 2.4E+05(+bkg)

Based on mean for calibration with mixture of radionuclides

    • Applicable during MODES 1 through 5. During MODE 6 (refueling), monitor setpoints shall be reduced to 2X background in accordance with Tech Spec Table 3.3-6
  • 49

Salem ODCM Rev. 5 12/21/88 Table 2-4 Controlling Locations, Pathways and Atmospheric Dispersion for Dose Calculations

  • Atmospheric Dispersion Technical Specification Location Pathway(s)

Controlling X/Q Age Group (sectm3>

3.11.2.1a site boundary noble gases N/A 2.2E-06 (0.83 mile, N) direct exposure 3.11.2.1b site boundary inhalation child 2.2E-06 (0.83 mi le, N) 3.11.2.2 site boundary gamma-air N/A 2.2E-06 (0.83 mi le, N) beta-air 3.11.2.3 residence/dairy milk and infant 5.4E-08 (4.8 mi Les, NNE) ground plane 6.9.1.10 Second sun direct exposure N/A 8.22E-06 (0.21 mile/SE) and inhalation

  • The identified controlling locations, pathways and atmospheric dispersion are from the Safety Evaluation Report, Supplement No. 3 for the Salem Nuclear Generating Station, Unit 2 (NUREG-0517, December 1978)
  • 50 D/Q (1/m2>

N/A N/A N/A 2.1E-10 N/A

Salem ODCM Rev. 5 12/21/88 Table 2-5 Pathway Dose Factors - Atmospheric Releases R ( io), Inhalation Pathway Dose Factors -

ADULT (mrem/yr per uci/m3)

Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3

1. 26E+3 1.26E+3
1. 26E+3 1.26E+3 l.26E+3
1. 26E+3 C-14 1.82E+4 3.41E+3 3.41E+3 3.41E+3 3.41E+3 3.41E+3 3.41E+3 P-32 1.32E+6 7.71E+4 8.64E+4 5.01E+4 Cr-51 5.95E+l 2.28E+l
1. 44E+4 3.32E+3 1.00E+2 Mn-54

. 3. 96E+4 9.84E+3 1.40E+6 7.74E+4 6.30E+3 Fe-55 2.46E+4

1. 70E+4 7.21E+4 6.03E+3 3.94E+3 Fe-59 1.18E+4 2.78E+4 1.02E+6 l.88E+5 1*.06E+4 Co-57 6.92E+2 3.70E+5 3.14E+4 6.71E+2 Co-58
1. 58E+3 9.28E+5 l.06E+5 2.07E+3 Co-60 1.15E+4 5.97E+6 2.85E+5
1. 48E+4 Ni-63 4.32E+5 3.14E+4 1.78E+5
1. 34E+4
1. 45E+4 Zn-65 3.24E+4 1.03E+5 6.90E+4 8.64E+5 5.34E+4 4.66E+4 Rb-86
1. 35E+5 l.66E+4 5.90E+4 Sr-89 3.04E+5
1. 40E+6 3.50E+5 8.72E+3 Sr-90 9.92E+7 9.60E+6 7.22E+5 6.10E+6 Y-91 4.62E+5 1.70E+6 3.85E+5
1. 24E+4 Zr-95
1. 07E+5
  • 3.44E+4 5.42E+4 1.77E+6 1.50E+5 2.33E+4 Nb-95
1. 41E+4 7.82E+3 7.74E+3 5.05E+5 1.04E+5 4.21E+3 Ru-103 1.53E+3 5.83E+3 5.05E+5 l.10E+5 6.58E+2 Ru-106 6.91E+4 1.34E+5 9.36E+6 9.12E+5 8.72E+3 Ag-llOm 1.08E+4 1.00E+4 1.97E+4 4.63E+6 3.02E+5 5.94E+3 Sb-124 3.12E+4 5.89E+2 7.55E+l 2.48E+6 4.06E+5
1. 24E+4 Sb-125 5.34E+4 5.95E+2 5.40E+l
1. 74E+6 1.0lE+5
1. 26E+4 Te-125m 3.42E+3 1.58E+3 1.05E+3 1.24E+4 3.14E+5 7.06E+4 4.67E+2 Te-127m 1.26E+4 5.77E+3 3.29E+3 4.58E+4 9.60E+5 1.50E+5
1. 57E+3 Te-129m 9.76E+3 4.67E+3 3.44E+3 3.66E+4 1.16E+6 3.83E+5
1. 58E+3 I-131 2.52E+4 3.58E+4 1.19E+7 6.13E+4 6.28E+3 2.05E+4 Cs-134 3.73E+5 8.48E+5 2.87E+5 9.76E+4 l.04E+4 7.28E+5 Cs-136 3.90E+4
1. 46E+5.

8.56E+4 1.20E+4 l.17E+4 1.10E+5 Cs-137 4.78E+5 6.21E+5 2.22E+5 7.52E+4 8.40E+3 4.28E+5 Ba-140 3.90E+4 4.90E+l

1. 67E+l 1.27E+6 2.18E+5 2.57E+3 Ce-141
1. 99E+4
1. 35E+4 6.26E+3 3.62E+5 l.20E+5 1.53E+3 Ce-144 3.43E+6 1.43E+6 8.48E+5 7.78E+6 8.16E+5 1.84E+5 Pr-143 9.36E+3 3.75E+3 2.16E+3 2.81E+5 2.00E+5 4.64E+2 Nd-147 5.27E+3 6.10E+3 3.56E+3 2.21E+5 1.73E+5 3.65E+2 51

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R ( io), Inhalation Pathway Dose Factors -

TEENAGER (mrem/yr per uci/m3)

Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3

1. 27E+3
1. 27E+3
1. 27E+3 1.27E+3 1.27E+3 l.27E+3 C-14 2.60E+4 4.87E+3 4.87E+3 4.87E+3 4.87E+3 4.87E+3 4.87E+3 P-32 1.89E+6 1.10E+5 9.28E+4 7.16E+4 cr-51 7.50E+l 3.07E+l 2.10E+4 3.00E+3 1.35E+2 Mn-54 5.11E+4 1.27E+4 1.98E+6 6.68E+4 8.40E+3 Fe-55 3.34E+4 2.38E+4 1.24E+5 6.39E+3 5.54E+3 Fe-59
1. 59E+4 3.70E+4 1.53E+6
1. 78E+5
1. 43E+4 Co-57 6.92E+2 5.86E+5 3.14E+4 9.20E+2 Co-58 2.07E+3 1.34E+6 9.52E+4 2.78E+3 Co-60
1. 51E+4 8.72E+6 2.59E+5 1.98E+4 Ni-63 5.80E+5 4.34E+4 3.07E+5
1. 42E+4 1.98E+4 Zn-65 3.86E+4 1.34E+5 a.64E+4 1.24E+6
4. 66E+4*

6.24E+4 Rb-86

1. 90E+5
1. 77E+4. 8. 40E+4 Sr-89 4.34E+5 2.42E+6 3.71E+5
1. 25E+4 Sr-90 1.08E+8 1.65E+7 7.65E+5 6.68E+6 Y-91 6.61E+5 2.94E+6 4.09E+5 1.77E+4 Zr-95 1.46E+5 4.58E+4 6.74E+4 2.69E+6
1. 49E+5 3.15E+4 Nb-95 1.86E+4 1.03E+4 1.00E+4 7.51E+5* 9.68E+4 5.66E+3 Ru-103 2.10E+3 7.43E+3 7.83E+5
1. 09E+5
8. 9.6E+2 Ru-106 9.84E+4 1.90E+5 1.61E+7 9.60E+5 1.24E+4 Ag-llOm
1. 38E+4 1.31E+4 2.50E+4 6.75E+6 2.73E+5 7.99E+3 Sb-124 4.30E+4 7.94E+2 9.76E+l 3.85E+6 3.98E+5 1.68E+4 Sb-125 7.38E+4 8.08E+2 7.04E+l 2.74E+6 9.92E+4
1. 72E+4 Te-125m 4.88E+3 2.24E+3 1.40E+3 5.36E+5 7.50E+4 6.67E+2 Te-127m 1.80E+4 8.16E+3 4.38E+3 6.54E+4 1.66E+6 1.59E+5 2.18E+3 Te-129m
1. 39E+4 6.58E+3 4.58E+3 5.19E+4 1.98E+6 4.05E+5 2.25E+3 I-131 3.54E+4 4.91E+4 1.46E+7 8.40E+4 6.49E+3 2.64E+4 Cs-134
  • 5.02E+5 1.13E+6 3.75E+5 1.46E+5 9.76E+3 5.49E+5 Cs-136 5.15E+4
1. 94E+5 1.10E+5 1.78E+4 1.09E+4 l.37E+5 Cs-137 6.70E+5 8.48E+5 3.04E+5 1.21E+5 8.48E+3 3.11E+5 Ba-140 5.47E+4 6.70E+l 2.28E+l 2.03E+6 2.29E+5 3.52E+3 Ce-141 2.84E+4 1.90E+4 8.88E+3 6.14E+5 1.26E+5 2.17E+3 Ce-144 4.89E+6 2.02E+6
i. 21E+6
1. 34E+7 8.64E+5 2.62E+5 Pr-143
1. 34E+4 5.31E+3 3.09E+3 4.83E+5 2.14E+5 6.62E+2 Nd-147 7.86E+3 8.56E+3 5.02E+3 3.72E+5
1. 82E+5 5.13E+2 52

.Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R(io), Inhalation Pathway Dose Factors -

CHILD (mrem/yr per uCi/m3)

Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 1.12E+3 1.12E+3 1.12E+3 1.12E+3 1.12E+3 1.12E+3 C-14 3.59E+4 6.73E+3 6.73E+3 6.73E+3 6.73E+3 6.73E+3 6.73E+3 P-32 2.60E+6 1.14E+5 4.22E+4 9.88E+4 cr...:51 8.55E+l 2.43E+l 1.70E+4 1.08E+3

1. 54E+2 Mn-54 4.29E+4 1.00E+4 1.58E+6 2.29E+4 9.51E+3 Fe-55 4.74E+4 2.52E+4 1.11E+5 2.87E+3 7.77E+3 Fe-59 2.07E+4 3.34E+4 1.27E+6 7.07E+4
1. 67E+4 Co-57 9.03E+2 5.07E+5
1. 32E+4 l.07E+3 Co-58 1.77E+3 1.11E+6 3.44E+4 3.16E+3 Co-60 1.31E+4 7.07E+6 9.62E+4 2.26E+4*

Ni-63 8.21E+5 4.63E+4 2.75E+5 6.33E+3 2.80E+4 Zn-65 4.26E+4 1.13E+5 7.14E+4 9.95E+5

1. 63E+4 7.03E+4 Rb-86 1.98E+5 7.99E+3 1.14E+5 Sr-89 5.99E+5 2.16E+6
1. 67E+5
1. 72E+4 Sr-90 1.01E+8 1.48E+7 3.43E+5 6.44E+6 Y-91 9.14E+5 2.63E+6
1. 84E+5 2.44E+4 Zr-95
1. 90E+5 4.18E+4 5.96E+4 2.23E+6 6.11E+4 3.70E+4 Nb-95 2.35E+4 9.18E+3 8.62E+3 6.14E+5 3.70E+4 6.55E+3 Ru-103 2.79E+3 7.03E+3 6.62E+5 4.48E+4 l.07E+3 Ru-106
1. 36E+5
1. 84E+5 1.43E+7 4.29E+5 l.69E+4 Ag-llOm
1. 69E+4 1.14E+4 2.12E+4 5.48E+6 1.00E+5 9.14E+3 Sb-124
5. 74,E+4 7.40E+2
1. 26E+2 3.24E+6 1.64E+5 2.00E+4 Sb-125 9.84E+4 7.59E+2 9.lOE+l 2.32E+6 4.03E+4 2.07E+4 Te-125m 6.73E+3 2.33E+3 1.92E+3 4.77E+5 3.38E+4 9.14E+2 Te-127m 2.49E+4 8.55E+3 6.07E+3 6.36E+4 1.48E+6 7.14E+4 3.02E+3 Te-129m
1. 92E+4 6.85E+3 6.33E+3 5.03E+4 1.76E+6
1. 82E;:5 3.04E+3 I-131 4.81E+4 4.81E+4 1.62E+7 7~88E+4 2.84E+3 2.73E+4 Cs-134 6.51E+5 1.01E+6 3.30E+5 1.21E+5 3.85E+3.2.25E+5 Cs-136 6.51E+4 1.71E+5 9.55E+4 1.45E+4 4.18E+3 l.16E+5 Cs-137 9.07E+5 8.25E+5 2.82E+5 1.04E+5 3.62E+3 1.28E+5 Ba-140 7.40E+4 6.48E+l 2.llE+l 1.74E+6 1.02E+5 4.33E+3 Ce-141 3.92E+4 l.95E+4 8.55E+3 5.44E+5 5.66E+4 2.90E+3 Ce-144 6.77E+6 2.12E+6 1.17E+6 1.20E+7 3.89E+5 3.61E+5 Pr-143 l.85E+4 5.55E+3 3.00E+J 4.33E+5 9.73E+4 9.14E+2 Nd-147 1.08E+4 8.73E+3 4.81E+3 3.28E+5 8.21E+4 6.81E+2 53

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R ( io), Inhalation Pathway Dose Factors -

INFANT (mrem/yr per uCi/m3)

Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 6.47E+2 6.47E+2 6.47E+2 6.47E+2 6.47E+2 6.47E+2 C-14 2.65E+4 5.31E+3 5.31E+3 5.31E+3 5.31E+3 5.31E+3 5.31E+3 P-32 2.03E+6 1.12E+5 1.61E+4 7.74E+4 Cr-51 5.75E+l* 1.32E+l 1.28E+4 3.57E+2 8.95E+l Mn-54 2.53E+4 4.98E+3 1.00E+6 7.06E+3 4.98E+3 Fe-55

1. 97E+4 1.17E+4 8.69E+4 1.09E+3 3.33E+3 Fe-59
1. 36E+4 2.35E+4 1.02E+6 2.48E+4 9.48E+3 Co-57 6.51E+2 3.79E+5 4.86E+3 6.41E+2 Co-58 1.22E+3 7.77E+5 1.11E+4 1.82E+3 Co-60 8.02E+3 4.51E+6 3.. 19E+4 1.18E+4 Ni-63 3.39E+5 2.04E+4 2.09E+5 2.42E+3 1.16E+4 Zn-65
1. 93E+4 6.26E+4 3.25E+4 6.47E+5 5.14E+4 3.11E+4 Rb-86
1. 90E+5 3.04E+3 8.82E+4 Sr-89 3.98E+5 2.03E+6 6.40E+4 1.14E+4 Sr-90 4.09E+7 1.12E+7 1.31E+5 2.59E+6 Y-91 5.88E+5 2.45E+6 7.03E+4 1.57E+4 Zr-95 1.15E+5 2.79E+4
  • 3.11E+4 1.75E+6 2.17E+4 2.03E+4 Nb-95 1.57E+4 6.43E+3 4.72E+3 4.79E+5 1.27E+4 3.78E+3 Ru-103 2.02E+3 4.24E+3 5.52E+5 1.61E+4 6.79E+2 Ru-106 8.68E+4 1.07E+5 1.16E+7 1.64E+5 1.09E+4 Ag-llOm 9.98E+3 7.22E+3 1.09E+4 3.67E+6 3.30E+4 5.00E+3 Sb-124 3.79E+4 5.56E+2 1.01E+2 2.65E+6 5.91E+4
1. 20E+4 Sb-125 5.17E+4 4.77E+2 6.23E+l 1.64E+6 1.47E+4 l.;09E+4 Te-125m 4.76E+3 1.99E+3 1.62E+3 4.47E+5 1.29E+4 6.58E+2 Te-127m
1. 67E+4 6.90E+3 4.87E+3 3.75E+4 1.31E+6 2.73E+4 2.07E+3 Te-129m
1. 41E+4 6.09E+3 5.47E+3 3.18E+4 1.68E+6 6.90E+4 2.23E+3 I-131 3.79E+4 4.44E+4
1. 48E+7 5.18E+4 1.06E.+3
1. 96E+4 Cs-134 3.96E+5 7.03E+5 1.90E+5 7.97E+4 1.33E+3 7.45E+4 Cs-136 4.83E+4 l.35E+5 5.64E+4 1.18E+4 l.43E+3 5.29E+4 Cs-137 5.49E+5 6.12E+5
1. 72E+5 7.13E+4
1. 33E+3 4.55E+4 Ba-140 5.60E+4 5.60E+l 1.34E+l 1.60E+6 3.84E+4 2.90E+3 Ce-141 2.77E+4
1. 67E+4 5.25E+3 5.17E+5 2.16E+4 1.99E+3 Ce-144 3.19E+6 1.21E+6 5.38E+5 9.84E+6 1.48E+5
1. 76E+5 Pr-143 1.40E+4 5.24E+3 1.97E+3 4.33E+5 3.72E+4 6.99E+2 Nd-147 7.94E+3 8.13E+3.

3.i5E+3 3.22E+5 3.12E+4 5.00E+2 54

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R ( io), Grass-Cow-Milk Pathway Dose Factors -

ADULT (mrem/yr per uCi/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 7.63E+2 7.63E+2 7.63E+2 7.63E+2 7.63E+2 7.63E+2 C-14 3.63E+5 7.26E+4 7.26E+4 7.26E+4 7.26E+4 7.26E+4 7.26E+4 P-32 1.71E+10 1.06E+9
1. 92E+9 6.60E+8 Cr-51
1. 71E+4 6.30E+3 3.80E+4 7.20E+6 2.86E+4 Mn-54 8.40E+6 2.50E+6 2.57E+7 1.60E+6 Fe-55 2.51E+7 1.73E+7 9.67E+6 9.95E+6 4.04E+6 Fe-59 2.98E+7 7.00E+7 1.95E+7 2.33E+8 2.68E+7 Co-57 1.28E+6 3.25E+7 2.13E+6 Co-58 4.72E+6 9.57E+7 1.06E+7 Co-60 1.64E+7 3.08E+8 3.62E+7 Ni-63 6.73E+9 4.66E+8 9.73E+7 2.26E+8 Zn-65 1.37E+9 4~36E+9 2.92E+9 2.75E+9
1. 97E+9 Rb-86 2.59E+9 5.11E+8 1.21E+9 Sr-89
1. 45E+9 2.33E+8 4.16E+7 Sr-90 4.68E+10 1.35E+9 1.15E+10 Y-91 8.60E+3 4.73E+6 2.30E+2 Zr-95 9.46E+2 3.03E+2 4.76E+2 9.62E+5 2.05E+2 Nb-95 8.25E+4 4.59E+4 4.54E+4 2.79E+8 2.47E+4 Ru-103 1.02E+3 3.89E+3 l.19E+5 4.39E+2 Ru-106 2.04E+4 3.94E+4
1. 32E+6 2.58E+3 Ag-llOm 5.83E+7 5.39E+7 1.06E+8 2.20E+10 3.20E+7 Sb-124 2.57E+7 4.86E+5 6.24E+4 2.00E+7
7. 31E+8 1.02E+7 Sb-125 2.04E+7 2.28E+5 2.08E+4 1.58E+7 2.25E+8 4.86E+6 Te-125m l.63E+7 5.90E+6 4.90E+6 6.63E+7 6.50E+7 2.18E+6 Te-127m 4.58E+7 1.64E+7 1.17E+7
1. 86E+8
1. 54E+8 5.58E+6 Te-129m 6.04E+7 2.25E+7 2.08E+7 2.52E+8 3.04E+8 9.57E+6 I-131 2.96E+8 4.24E+8 1.39E+ll 7.27E+8 1.12E+8 2.43E+8 Cs".'"134 5.65E+9 1.34E+10 4.35E+9 1.44E+9 2.35E+8 1.lOE+lO Cs-136 2.61E+8 1.03E+9 5.74E+8 7.87E+7 1.17E+8 7.42E+8 Cs-137 7.38E+9 1.0lE+lO 3.43E+9 1.14E+9 1.95E+8 6.61E+9 Ba-140 2.69E+7 3.38E+4 1.15E+4 1.93E+4 5.54E+7 1.76E+6 Ce-141 4.84E+3 3.27E+3 1.52E+3
1. 25E+7 3.71E+2.

Ce-144 3.58E+5 1.50E+5 8.87E+4

1. 21E+8
1. 92E+4 Pr-143 l.59E+2 6.37E+l 3.68E+l 6.96E+5 7.88E+O Nd-147 9.42E+l 1.09E+2 6.37E+l 5.23E+5 6.52E+O 55

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R(io), Grass-Cow-Milk Pathway Dose Factors -

TEENAGER (mrem/yr per uCi/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 9.94E+2 9.94E+2 9.94E+2 9.94E+2 9.94E+2 9.94E+2 C-14 6.70E+5
1. 34E+5
1. 34E+5
1. 34E+5 1.34E+5
1. 34E+5 1.34E+5 P-32 3.15E+10 1.95E+9 2.65E+9 1.22E+9 Cr-51 2.78E+4 1.10E+4 7.13E+4 8.40E+6 5.00E+4 Mn-54 1.40E+7 4.17E+6 2.87E+7 2.78E+6 Fe-55 4.45E+7 3.16E+7 2.00E+7
1. 37E+7 7.36E+6 Fe-59 5.20E+7
1. 21E+8 3.82E+7 2.87E+8 4.68E+7 Co-57 2.25E+6 4.19E+7 3.76E+6 Co-58 7.95E+6 1.10E+8 1.83E+7 Co-60 2.78E+7 3.62E+8 6.26E+7 Ni-63 1.18E+10 8.35E+8
1. 33E+8 4.01E+8 Zn-65 2.11E+9 7.31E+9 4.68E+9 3.10E+9 3.41E+9 Rb-86 4.73E+9 7.00E+8 2.22E+9 Sr-89 2.67E+9 3.18E+8 7.66E+7 Sr-90 9.92E+7 9.60E+6 7.22E+5 6.10E+6 Y-91 1.58E+4 6.48E+6 4.24E+2 Zr-95
1. 65E+3 5.22E+2 7.67E+2 1.20E+6
3. 59E+2
  • Nb-95
1. 41E+5 7.80E+4 7.57E+4 3.34E+8 4.30E+4 Ru-103 1.81E+3 6.40E+3 1.52E+5 7.75E+2 Ru-106 3.75E+4 7.23E+4 1.80E+6 4.73E+3 Ag-llOm 9.63E+7 9.11E+7
1. 74E+8 2.56E+l0 5.54E+7 Sb-124 4.59E+7 8.46E+5 1.04E+5 4.01E+7 9.25E+8 1.79E+7 Sb-125 3.65E+7 3.99E+5 3.49E+4 3.21E+7 2.84E+8 8~54E+6 Te-125m 3.00E+7 1.08E+7 8.39E+6 8.86E+7 4.02E+6 Te-127m 8.44E+7 2.99E+7 2.01E+7 3.42E+8 2.10E+8 1.00E+7 Te-129m 1.11E+8 4.10E+7 3.57E+7 4.62E+8 4.15E+8
1. 75E+7 I-131 5.38E+8 7.53E+8 2.20E+ll l.30E+9 l.49E+8 4.04E+8 Cs-134 9.81E+9 2.31E+10 7.34E+9 2.80E+9 2.87E+8
1. 07E+10 Cs-136 4.45E+8
1. 75E+9 9.53E+8 1.50E+8 1.41E+8 1.18E+9 Cs-137 l.34E+10 l.78E+l0 6.06E+9 2.35E+9 2.53E+8 6.20E+9 Ba-140 4.85E+7 5.95E+4 2.02E+4 4.00E+4 7.49E+7 3.13E+6 Ce-141 8.87E+3 1.35E+4 2.79E+3 l.69E+7 6.81E+2 '

Ce-144 6.58E+5 2.72E+5

1. 63E+5 l.66E+8 3.54E+4 Pr-143 2.92E+2
1. l 7E+2 6.77E+l 9.61E+5
1. 45E+l Nd-147 1.81E+2 1.97E+2 l.16E+2 7.11E+5 1.18E+l 56

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R(io), Grass-Cow-Milk Pathway Dose Factors -

CHILD (mrem/yr per uCi/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3
1. 57E+3
1. 57E+3
1. 57E+3 1.57E+3 1.57E+3
1. 57E+3 C-14 1.65E+6 3.29E+5 3.29E+5 3.29E+5 J.29E+5 3.29E+5 J.29E+5 P-32 7.77E+10 3.64E+9 2.15E+9 3.00E+9 Cr-51 5.66E+4 1.55E+4 1.03E+5 5.41E+6 l.02E+5 Mn-54 2.09E+7 5.87E+6 1.76E+7 5.58E+6 Fe-55 1.12E+8 5.93E+7 3.35E+7 1.10E+7 l.84E+7 Fe-59 1.20E+8 1.95E+8 5.65E+7 2.03E+8 9.71E+7 Co-57 3.84E+6 3.14E+7 7.77E+6 Co-58
1. 21E+7 7.08E+7 3.72E+7 Co-60 4.32E+7 2.39E+8
1. 27E+8 Ni-63 2.96E+10 1.59E+9 1.07E+8 1.01E+9 Zn-65 4.13E+9 1.lOE+lO 6.94E+9
1. 93E+9 6.85E+9 Rb-86 8.77E+9 5.64E+8 5.39E+9*

Sr-89 6.62E+9 2.56E+8

1. 89E+8 Sr-90 1.12E+ll 1.51E+9 2.83E+l0 Y-91 3.91E+4 5.21E+6 1.04E+3 '

Zr-95 3.84E+3 8.45E+2

1. 21E+3 8.81E+5 7.52E+2 Nb-95 3.18E+5
1. 24E+5 1.16E+5 2.29E+8 8.84E+4 Ru-103 4.29E+3 1.08E+4 1.11E+5
1. 65E+3 Ru-106 9.24E+4
1. 25E+5 l._44E+6 1.15E+4 Ag-llOm 2.09E+8
1. 41E+8 2.63E+8 1.68E+10 1.13E+8 Sb-124
1. 09E+8 1.41E+8 2.40E+5 6.03E+7 6.79E+8 3.81E+7 Sb-125 8.70E+7
1. 41E+6 8.06E+4 4.85E+7 2.08E+8
1. 82E+7 Te-125m 7.38E+7 2.00E+7 2.07E+7 7.12E+7 9.84E+6 Te-127m 2.08E+8 5.60E+7 4.97E+7 5.93E+8 1.68E+8 2.47E+7 Te-129m 2.72E+8 7.61E+7 8.78E+7 8.00E+S 3.32E+8 4.23E+7 I-131 1.30E+9
1. 31E+9 4.34E+ll 2.15E+9 1.17E+8 7.46E+8 cs-134 2.26E+l0 3.71E+10 l.15E+10 4.13E+9 2.00E+8 7.83E+9 Cs-136 1.00E+9 2.76E+9 1.47E+9 2.19E+8 9.70E+7 1.79E+9 Cs-137 3.22E+10 3.09E+l0 1.0lE+lO 3.62E+9
1. 93E+8 4.55E+9 Ba-140 1.17E+8 1.03E+5 3.34E+4 6.12E+4 5.94E+7 6.84E+6 Ce-141 2.19E+4 1.09E+4 4.78E+3 1.36E+7
1. 62E+3 Ce-144 l.62E+6 5.09E+5 2.82E+5 1.33E+8 8.66E+4 Pr-143 7.23E+2 2.17E+2 1.17E+2 7.80E+5 3.59E+l Nd-147 4.45E+2 3.60E+2 l.98E+2 5.71E+5 2.79E+l 57

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R(io), Grass-Cow-Milk Pathway Dose Factors -

INFANT (mrem/yr per uCi/m3) for H-3 and C-14

. (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 2.38E+3 2.38E+3 2.38E+3 2.38E+3 2.38E+3 2.38E+3 C-14 3.23E+6 6.89E+5 6.89E+5 6.89E+5 6.89E+5 6.89E+5 6.89E+5 P-32 1.60E+ll 9.42E+9 2.17E+9 6.21E+9 Cr-51 1.05E+5 2.30E+4 2.05E+5 4.71E+6
1. 61E+5 Mn-54 3.89E+7 8.63E+6
1. 43E+7 8.83E+6 Fe-55
1. 35E+8 8.72E+7 4.27E+7 1.11E+7 2.33E+7 Fe-59 2.25E+8 3.93E+8 1.16E+8 1.88E+8 1.55E+8 Co-57 8.95E+6 3.05E+7 1.46E+7 Co-58 2.43E+7 6.05E+7 6.06E+7 Co-60 8.81E+7 2.10E+8 2.08E+8 Ni-63 3.49E+10 2.16E+9 l.07E+8 l.21E+9 Zn-65 5.55E+9 1. 90E+10 9.23E+9
1. 61E+10 8.78E+9 Rb-86 2.. 22E+10 5.69E+8 1.lOE+lO Sr-89
1. 26E+10 2.59E+8 3.61E+8 sr-90
1. 22E+ll 1.52E+9 3.lOE+lO Y-91 7.33E+4 5.26E+6
1. 95E+3 Zr-95 6.83E+3
1. 66E+3
1. 79E+3 8.28E+5 1.18E+3 Nb-95 5.93E+5 2.44E+5 1.75E+5 2.06E+8
1. 41E+5 Ru-103 8.69E+3 1.81E+4 1.06E+5 2.91E+3 Ru-106
1. 90E+5 2.25E+5 1.44E+6 2.38E+4 Ag-llOm 3.86E+8 2.82E+8 4.03E+8 1 *.46E+10
1. 86E+8 Sb-124 2.09E+8 3.08E+6 5.56E+5 1.31E+8 6.46E+8 6.49E+7 Sb-125 1.49E+8
1. 45E+6 1.87E+5 9.38E+7
1. 99E+8 3.07E+7 Te-125m
1. 51E+8 5.04E+7 5.07E+7 7.18E+7 2.04E+7 Te-127m 4.21E+8
1. 40E+8 1.22E+8 1.04E+9 1.70E+8 5.10E+7 Te-129m 5.59E+8
1. 92E+8 2.15E+8 1.40E+9 3.34E+8 8.62E+7 I-131 2.72E+9 3.21E+9 1.05E+12 3.75E+9 1.15E+8
1. 41E+9 Cs-134 3.65E+l0 6.80E+10
1. 75E+10 7.18E+9 1.85E+8 6.87E+9 Cs-136 1.96E+9 5.77E+9 2.30E+9 4.70E+8 8.76E+7 2.15E+9 Cs-137 5.15E+10 6.02E+10
1. 62E+10 6.55E+9 1.88E+8 4.27E+9 Ba-140 2.41E+8 2.41E+5 5.73E+4 1.48E+5 5.92E+7 1.24E+7 Ce-141 4.33E+4 2.64E+4 8.15E+3 1.37E+7 3.11E+3 Ce-144 2.33E+6 9.52E+5 3.85E+5 1.33E+8
1. 30E+5 Pr-143
1. 49E+3 5.59E+2 2.08E+2 7.89E+5 7.41E+l Nd-147 8.82E+2
9. 06E+2.

3.49E+2 5.74E+5 5.55E+l 58

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R(io), Vegetation Pathway Dose Factors -

ADULT (mrem/yr per uCi/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body H-3 2.26E+3 2.26E+3 2.26E+3 2.26E+3 2.26E+3 2.26E+3 C-14 8.97E+5
1. 79.E+5 1.79E+5
1. 79E+5 1.79E+5 1.79E+5
1. 79E+5 P-32 1.40E+9 8.73E+7 1.58E+8 5.42E+7 Cr-51 2.79E+4 l.03E+4 6.19E+4 1.17E+7 4.66E+4 Mn-54 3.11E+8 9.27E+7 9.54E+8 5.94E+7 Fe-55 2.09E+8 l.45E+8 8.06E+7 8.29E+7 3.37E+7 Fe-59 l.27E+8 2.99E+8 8.35E+7 9.96E+8 1.14E+8 Co-57 l.17E+7 2.97E+8 l.95E+7 Co-58 3.09E+7 6.26E+8 6.92E+7
  • co-60 1.67E+8 3.14E+9 3.69E+8 Ni-63 l.04E+10 7.21E+8 1.50E+8 3.49E+8 Zn-65 3.17E+8 1.01E+9 6.75E+8 6.36E+8 4.56E+8 Rb-86 2.19E+8 4.32E+7 l.02E+8 Sr-89 9.96E+9 1.60E+9 2.86E+8 Sr-90 6.05E+ll 1.75E+10 1.48E+ll Y-91 5.13E+6 2.82E+9
1. 37E+5 Zr-95 l.19E+6 3.81E+5 5.97E+5 1.21E+9 2.58E+5 Nb-95 1.42E+5 7.91E+4 7.81E+4 4.80E+8 4.25E+4 Ru-103 4.80E+6
1. 83E+7 5.61E+8 2.07E+6 Ru-106 1.93E+8 3.72E+8 1.25E+l0 2.44E+7 Ag-llOm l.06E+7 9.76E+6
1. 92E+7 3.98E+9 5.80E+6 Sb-124 l.04E+8
1. 96E+6 2.52E+5 8.08E+7 2.95E+9 4.11E+7 Sb-125 l.36E+8 1.52E+6 1.39E+5 1.05E+8 1.50E+9 3.25E+7 Te-125m 9.66E+7 3.50E+7 2.90E+7 3.93E+8 3.86E+8
1. 29E+7 Te-127m 3.49E+8
1. 25E+8 8.92E+7 l.42E+9 1.17E+9* 4.26E+7 Te-129m
  • 2.55E+8 9.50E+7 8.75E+7 1.06E+9 1.28E+9 4.0JE+7 I-131 8.09E+7 l.16E+8 3.79E+10 1.98E+8 3.05E+7 6.63E+7 Cs-134 4.66E+9 l. llE+lO 3.59E+9 l.19E+9 1.94E+8 9.07E+9 Cs-136 4.20E+7 1.66E+8 9.24E+7 1.27E+7 1.89E+7 l.19E+8 Cs-137 6.36E+9 8.70E+9 2.95E+9 9.81E+8 1.68E+8 5.70E+9 Ba-140
1. 29E+8
1. 62E+5 5.49E+4 *9. 25E+4 2.65E+8 8.43E+6 Ce-141 *
1. 96E+5
1. 33E+5 6.17E+4 5.08E+8 1.51E+4 Ce-144 3.29E+7
1. 38E+7 8.16E+6 1.llE+lO
1. 77E+6 Pr-143 6.34E+4 2.54E+4
1. 47E+4 2.78E+8 3.14E+J Nd-147 3.34E+4 3.86E+4 2.25E+4 1.85E+8 2.31E+3 59

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R ( io), Vegetation Pathway Dose Factors -

TEENAGER (mrem/yr per uCi/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body

--~----

H-3 2.59E+3 2.59E+3 2.59E+3 2.59E+3 2.59E+3 2.59E+3 C-14

1. 45E+6 2.91E+5 2.91E+5 2.91E+5 2.91E+5 2.91E+5 2.91E+5 P-32
1. 61E+9 9.96E+7 1.35E+8 6.23E+7 cr-51 3.44E+4
1. 36E+4 8.85E+4 1.04E+7 6.20E+4 Mn-54 4.52E+8 l.35E+8 9.27E+8 8.97E+7 Fe-55 3.25E+8 2.31E+8 1.46E+8 9.98E+7 5.38E+7 Fe-59 1.81E+8 4.22E+8 1.33E+8 9.98E+8
1. 63E+8 Co-57 1.79E+7 3.34E+8 3.00E+7 Co-58 4.38E+7 6.04E+8 1.01E+8 Co-60 2.49E+8 3.24E+9 5.60E+8 Ni-63 1.61E+10 1.13E+9
1. 81E+8 5.45E+8 Zn-65 4.24E+8
1. 47E+9 9.41E+8 6.23E+8 6.86E+8 Rb-86 2.73E+8 4.05E+7
1. 28E+8 Sr-89 1.51E+10 1.80E+9 4.33E+8 Sr-90 7.51E+ll 2.llE+lO l.85E+ll Y-91 7.87E+6 3.23E+9 2.11E+5 Zr-95
1. 74E+6 5.49E+5 8.07E+5 1.27E+9 3.78E+5 Nb-95
1. 92E+5
1. 06E+5 1.03E+5 4.55E+8 5.86E+4 Ru-103 6.87E+6 2.42E+7 5.74E+8 2.94E+6 Ru-106

,J 3. 09E+8 5.97E+8 1.48E+10 3.90E+7 Ag-llOm

1. 52E+7
1. 44E+7 2.74E+7 4.04E+9 8.74E+6 Sb-124
1. 55E+8 2.85E+6 3.51E+5 1.35E+8 3.11E+9 6.03E+7 Sb-125 2.14E+8 2.34E+6 2.04E+5 1.88E+8 1.66E+9 5.00E+7 Te-125m 1.48E+8 5.34E+7 4.14E+7 4.37E+8 1.98E+7 Te-127m 5.51E+8
1. 96E+8
1. 31E+8 2.24E+9
1. 37E+9 6.56E+7 Te-129m 3.67E+8
1. 36E+8 1.18E+8 1.54E+9
1. 38E+9 5.81E+7 I-131 7.70E+7 1.08E+8 3.14E+l0 1.85E+8 2.13E+7 5.79E+7 Cs-134 7.09E+9 1. 67E+10 5.30E+9 2.02E+9 2.08E+8 7.74E+9 Cs-136 4.29E+7 1.69E+8 9.19E+7 1.45E+7
1. 36E+7 1.13E+8 Cs-137
1. OlE+lO 1.35E+10 4.59E+9 1.78E+9
1. 92E+8 4.69E+9 Ba-140
1. 38E+8 1.69E+5 5.75E+4 1.14E+5 2.13E+8 - 8.91E+6 Ce-141 2.82E+5
1. 88E+5 8.86E+4 5.38E+8 2.16E+4 Ce-144 5.27E+7 2.18E+7 1.30E+7
1. 33E+10 2.83E+6 Pr-143 7.12E+4 2.84E+4
1. 65E+4 2.34E+8 3.55E+3 Nd-147 3.63E+4 3.94E+4 2.32E+4
1. 42E+8 2.36E+3 60

Salem ODCM Rev. 5 12;2*1/88 Table 2-5 (cont'd)

R(io), Vegetation Pathway Dose Factors -

CHILD (mrem/yr per uci/m3) for H-3 and C-14 (m2

  • mrem/yr per uCi/sec) for others Nuclide Bone Liver Thyroid Kidney Lung GI-LLI T.Body
  • H-3 4.01E+3 4.01E+3 4.01E+3 4.0lE+3 4.01E+3 4.01E+3 C-14 3.50E+6 7.01E+5 7.01E+5 7.01E+5 7.01E+5 7.01E+5 7.01E+5 P-32

.3. 37E+9 1.58E+8 9.30E+7 1.30E+8 Cr-51 6.54E+4

1. 79E+4 1.19E+5 6.25E+6 1.18E+5 Mn-54 6.61E+8
1. 85E+8 5.55E+8
1. 76E+8 Fe-55 8.00E+8 4.24E+8 2.40E+8 7.86E+7
1. 31E+8 Fe-59 4.01E+8 6.49E+8 l.88E+8 6.76E+8 3.23E+8 Co-57 2.99E+7 2.45E+8 6.04E+7 Co-58 6.47E+7 3.77E+8
1. 98E+8 Co-60 3.78E+8 2.10E+9 1.12E+9 Ni-63 3.95E+10 2.11E+9
1. 42E+8
1. 34E+9 Zn-65 8.i2E+8 2.16E+9
1. 36E+9 3.80E+8
1. 35E+9 Rb-86 4.52E+8 2.91E+7 2.78E+8 Sr-89 3.59E+10
1. 39E+9 1.03E+9 Sr-90
1. 24E+12
1. 67E+10 3.15E+ll Y-91 l.87E+7 2.49E+9 5.01E+5 Zr-95 3.90E+6 8.58E+5
1. 23E+6 8.95E+8 7.64E+5 Nb-95 4.10E+5 1.59E+5
1. 50E+5 2.95E+8 1.14E+5 Ru-103
1. 55E+7 3.89E+7 3.99E+8 5.94E+6 Ru-106 7.45E+8 1.01E+9 1.16E+10 9.30E+7 Ag-llOm 3.22E+7 2.17E+7 4.05E+7 2.58E+9 1.74E+7 Sb-124 3.52E+8 4.57E+6 7.78E+5 1.96E+8 2.20E+9
1. 23E+8 Sb-125 4.99E+8 3.85E+6 4.62E+5 2.78E+8 1.19E+9 1.05E+8 Te-125m 3.51E+8 9.50E+7 9.84E+7 3.38E+8 4.67E+7 Te-127m 1.32E+9 3.56E+8 3.16E+8 3.77E+9 1.07E+9
1. 57E+8 Te-129m 8.54E+8 2.39E+8 2.75E+8 2.51E+9 1.04E+9 1.33E+8 I-131
1. 43E+8 1.44E+8 4.76E+10 2.36E+8 1.28E+7 8.18E+7 Cs-134 1.60E+l0 2.63E+10 8.14E+9 2.92E+9
1. 42E+8 5.54E+9 Cs-136 8.06E+7 2.22E+8 l.18E+8 1.76E+7 7.79E+6 1.43E+8 Cs-137 2.39E+10 2.29E+l0 7.46E+9 2.68E+9 1.43E+8 3.38E+9 Ba-140 2.77E+8 2.43E+5 7.90E+4 l.45E+5 l.40E+8
1. 62E+7 Ce-141
1. 23E+5 6.14E+4 2.69E+4 7.66E+7 9.12E+3 Ce-144
1. 27E+8 3.98E+7 2.21E+7
1. 04E+10 6.78E+6 Pr-143 1.48E+5 4.46E+4 2.41E+4 1.60E+8 7.37E+3 Nd-147 7.16E+4 5.80E+4 3.18E+4 9.18E+7 4.49E+3 61

Salem ODCM Rev. 5 12/21/88 Table 2-5 (cont'd)

R ( io), Ground Plane Pathway Dose Factors (m2

  • mrem/yr per uCi/sec)

Nuclide Any Organ H-3 C-14 P-32 Cr-51 4.68E+6 Mn-54

1. 34E+9 Fe-55 Fe-59 2.75E+8 Co-58 3.82E+8 Co-60 2.16E+10 Ni-63 Zn-65 7.45E+8 Rb-86 8.98E+6 Sr-89 2.16E+4 Sr-90 Y-91 1.08E+6 Zr-95 2.48E+8 Nb-95
1. 36E+8 Ru-103 l.09E+8 Ru-106.

4.21E+8 Ag-llOm 3.47E+9 Te-125m 1.55E+6 Te-127m 9.17E+4 Te-129m 2.00E+7*

I-131

1. 72E+7 Cs-134 6.75E+9 Cs-136
1. 49E+8 Cs-137 1.04E+10 Ba-140 2.05E+7 Ce-141 1.36E+7 Ce-144 6*. 95E+7 Pr-143 Nd-147 8.40E+6 62

Salem ODCM Rev. 5 12/21/88 APPENDIX A Evaluation of Default MPC Value for Liquid Effluents A-1

Salem ODCM Rev. 5 12/21/88 Appendix A Evaluation of Default MPC Value for Liquid Effluents In accordance with the requirements of Technical Specification (3.3.3.10) the radioactive liquid effluent monitors shall be operable with alarm setpoints established to ensure that the concentration of radioactive material at the discharge point does not exceed the MPC value of 10 CFR 20, Appendix B, Table II, Column 2.

The determination of allowable radionuclide concentration and corresponding alarm setpoint is a function of the individual radionuclide distribution and corresponding MPC values.

In order to limit the need for routinely having to reestablish the alarm setpoints as a function of changing radionuclide distributions, a default alarm setpoint can be established.

This default setpoint can be based on an evaluation of the radionuclide distribution of the liquid effluents from Salem and the effective MPC value for this distribution.

The effective MPC value for a radionuclide distribution is calculated by the equation:

C*

l.

A-2 (A. l)

where:

MP Ce C*

l MPCi

=

=

=

Salem ODCM Rev. 5 12/21/88 an effective MPC value for a mixture of radionuclide (uCi/ml) concentration of radionuclide i in the mixture the 10 CFR 20, Appendix B, Table II, Column 2 MPC value for radionuclide i (uCi/ml)

Based on the above equation and the radionuclide distribution in the effluents for past years from Salem, an effective MPC value can be determine. Results are presented in Table A-1 and A-2 for Uriit 1 and Unit 2, respectively.

Considering the average effective MPC value for the years 1981 through 1987, it is reasonable to select an MPCe value of lE-05 uci/ml as typical of liquid radwaste discharges.

Using this value to calculate the default R18 alarm setpoint value, results in a setpoint that:

1)

Will not require frequent readjustment due to minor variations in the nuclide distribution which are typical of routine plant operations, and

2)

Will provide for a liquid radwaste discharge rate (as evaluated for each batch release) that is compatible with plant operations (refer to Tables 1-1 and 1-2)

  • A-3

Nuclide MPC (uCi/ml)

Na-24 3E-05 Cr-51 2E-03 Mn-54 1E-04 Fe-59 5E-05 Co-58 9E-05 Co-60 3E-05 Zr-95 6E-05 Nb-95 1E-04 Nb-97 9E-04 Tc-99m 3E-03 Sr-89 3E-06 Sr-90.

3E-07 Mo-99 4E-05 Ag-110m 3E-05 Sn-113 8E-05 Sb-124 2E-05 Sb-125 1E-04 I*131 3E-07 I*133 1E-06 I-135 4E-06 Cs-134 9E-06 Cs-137 2E-05 Ba-140 2E-05

c. MPCi MPCe (uCi/ml)

Table A-1 Calculation of Effective MPC Salem Unit 1 Salem ODCM Rev. 5 12/21/88 Activity Released (Ci) 1982 1983 1984 1985 1986 1987 1.9E-03 5.3E-03 5.6E-03 6.2E-03 9.2E-04 6.9E-04 1.4E-01 6.2E-02 5.3E-02 3.6E-02 6.0E-02 N/D 2.1E-01 1.6E-01 1.9E-01 8.7E-02 1.9E-01 1.0E-01 8.6E-03 4.2E-02 5.SE-03 1.4E-03 2.4E-03 N/D 1.7 1.8 1.6 6.6E-01 2.22 1.54 9.1E-01 7.1E-01 1.2 6.5E-01 3.1E-01 4.2E-01 1.1E-02 8.0E-03 1.8E-03 3.2E-03 4.3E-03 8.6E-04 4.8E-02 2.2E-02 1.7E-02 1.3E-03 1.8E-02 2.4E-03 9.5E-03 3.6E-04 2.0E-02 7.2E-03 1.5E-03 9.8E-03 N/D N/D 1.6E-03 N/D N/D 1.1E-04 N/D 1.2E-03 4.2E-04

1. 7E-03 3.5E-07 1.6E-02 N/D N/D 2.2E-05
1. 7E-04 3.1E-08 7.7E-04 1.0E-03 1.6E-03 1.9E-03 1.0E-04 N/D 1.0E-04 4.7E-03 N/D N/D N/D N/D 2.8E-03 2.2E-04

. 3.8E-04 9.4E-04 N/D 3.5E-04 N/D 8.0E-03 1.4E-02 1.7E-02 5.7E-03 8.4E-02 2.4E-02 6.8E-03 4.4E-02 4.9E-03 N/D 3.6E-02 3.3E-02 6.5E-02 2.4E-02 4.5E-02 7.9E-02 1.2E-01 1.8E-01 3.3E-02 2.5E-02 1.9E-02 1.4E-03 1.9E-02 3.5E-04 1.6E-03 1.2E-03 N/D N/D 2.0E-03 4.0E-02 1.8E-02 5.1E-02 1.6E-01

  • 3.4E-01 3.1E-03 5.9E-02 3.0E-02 5.8E-02 2.1E-01 3.6E-01 3.0E-01 N/D 1.3E-02 2.1E-03 N/D N/D N/D 7.5E-03 1.3E-02 1.6E-02 1.1E-04 3.5E-04 N/D 3.24 3.00 3.32 1.93 3.75 3.26 2.83E+05 1.66E+05 2.46E+05 3.42E+05 4.99E+05 7.31E+05 1.14E-05 1.80E-05 1.35E-05 5.63E-06 7.51E-06 4.46E-06 MPC value for unrestricted area from 10 CFR 20, Appendix B, Table II, Colllll1 2.

N/D - not detected A-4

Salem ODCM Rev. 5 12/21/88 Table A-2 Calculation of Effective MPC Salem Unit 2 Activity Released (Ci)

Nuclide MPC 1982 1983 1984 1985 (uCi/ml)

Na-24 3E-05 1.2E-03 9.2E-03 4.4E-03 3.5E-03 Cr-51 2E-03 1.1E-01 4.6E-02 3.6E-02 3.5E-02 Mn-54 1E-04 2.0E-01 1.4E-01 1.6E-01 1.1E-01 Fe-59 5E-05 5.6E-03 3.1E-02 7.6E-03 1.1E-03 Co-58 9E-05

1. 7
1. 7 1.3 8.4E-01 Co-60 3E-05 8.6E-01 5.7E-01 9.8E-01 6.3E-01 Zr-95 6E-05 9.7E-03 5.2E-03 1.2E-03 4.6E-03 Nb-95 1E-04 2.3E-02 1.6E-02 1.4E-02 1.4E-02 Nb-97 9E-04 1.1E-02 1.1E-02 2.1E-02 5.7E-03 Tc-99m 3E-03 N/D N/D 1.4E-03 N/D Sr-89 3E-06 N/D 3.2E-04 3.2E-04 1.5E-03 Sr-90 3E-07 N/D N/D 4.1E-05 1.0E-04 Mo-99 4E-05
1. 7E-04 3.0E-03 1.4E-03 N/D Ag-110m 3E-05 3.9E-03 N/D N/D N/D Sn-113 8E-05 1.6E-04 5.9E-04 1.2E-03 N/D Sb-124 2E-05 1.0E-02 2.0E-02 3.0E-02 1.2E-03 Sb-125 1E-04 1.0E-02 9.6E-02 3.6E-03 N/D I-131 3E-07 1.3E-01 3.6E-02 4.2E-02 8.4E-02 I-133 1E-06 6.0E-03 5.4E-02 2.6E-02 1.2E-02 I-135 4E-06 N/D 1.6E-03 4.4E-04 N/D Cs-134 9E-06 5.1E-02 2.0E-02 2.6E-02 1.8E-01 Cs-137 2E-05 7.6E-02 3.6E-02 4.8E-02 2.3E-01 Ba-140 2E-05 N/D 9.8E-03 6.6E-03 N/D La-140 2E-05 6.7E-03 8.1E-02 3.0E-02 N/D Total C; 3.21 2.89 2.74 2.15
c. 5.00E+05 2.26E+05 2.24E+05 3.56E+05 MPCi MPCe (uCi/ml) 6.42E-06 1.28E-05 1.22E-05 6.04E-06 MPC value for unrestricted area from 10 CFR 20, Appendix B, Table II, Col1.1111 2.

N/D - not detected A-5 1986 1987 3.6E-03 7.3E-05 9.5E-02 3.0E-03 2.2E-01 1.2E-01 4.0E-03 N/D 3.32

1. 7 3.8E-01 4.2E-01 1.1E-02 8.4E-04 2.5E-02 6.6E-03 2.7E-03 N/D N/D 5.7E-04 4.1E-07 3.0E-03 3.2E-08 2.9E-04 N/D 4.4E-04 N/D N/D 1.1E-03 N/D 1.2E-01 4.6E-02 5.4E-02 5.9E-02 1.2E-01 2.2E-01 2.6E-03 1.8E-02 N/D N/D 3.6E-01 3.5E-01 3.7E-01 3.3E-01 N/D N/D 6.9E-04 N/D 5.09 3.85 5.20E+05 8.59E+05 9.79E-06 4.49E-06

Salem ODCM Rev. 5 12/21/88 APPENDIX B Technical Basis for Effective Dose Factors Liquid Radioactive Effluent B-1

Salem ODCM Rev. 5 12/21/88 APPENDIX B Technical Basis for Effective Dose Factors -

Liquid Effluent Releases The radioactive liquid effluents for the years 1987, 1986, 1985, 1984, 1983, and 1982 were evaluated to determine the dose contribution of the radionuclide distribution.

This analysis was performed to evaluate the use of a limited dose analysis for determining environmental doses, providing a simplified method of determining compliance with the dose limits of Technical Specification 3.11.1.2.

For the radionuclide distribution of effluents from Salem, the controlling organ is the GI-LLI.

The calculated GI-LLI dose is predominately a function of the Fe-59, C0-58, C0-60 and Nb-95 releases. The radionuclides, Co-58 and C0-60 contribute the large majority of the calculated total body dose.

The results of the evaluation for 1987, 1986, and 1985 are presented in Table B-1 and Table B-2.

For purposes of simplifying the details of the dose calculation process,* it is conservative to identify a controlling, dose significant radionuclide and limit the calculation process to the use of the dose conversion factor for this nuclide.

Multiplication of the total release (i.e., cumulative activity for all radionuclides) by this dose conversion factor provides for a dose calculation method that is simplified while also being conservative.

B-2

Salem ODCM Rev. 5 12/21/88 For the evaluation of the maximum organ dose, it is conservative to use the Nb-95 dose conversion factor (1.51 E+06 mrem/hr per uCi/ml, GI-LLI).

By this approach, the maximum organ dose will be overestimated since this nuclide has the highest organ dose factor of all the radionuclides evaluated. For the total body calculation, the Fe-59 dose factor (7.27 E+04 mrem/hr per uCi/ml, total body) is the highest among the identified dominant nuclides.

For evaluating compliance with the dose limits of Technical Specification 3.11.1.2, the following simplified equations may be used:

Total Body 1.67E-02

  • VOL where:

Dtb A Fe-59,TB VOL Ci cw l.67E-02

  • A Fe-59,TB *

(B.1) cw

= dose to the total body (mrem)

= 7.27E+04, total body ingestion dose conversion factor for Fe-59 (mrem/hr per uCi/ml)

= volume of liquid effluent released (gal)

= total concentration of all radionuclides (uCi/ml)

= average circulating water discharge rate during release period (gal/min)

= conversion factor (hr/min)

Substituting the value for the Fe-59 total body dose conversion factor, the equation simplifies to:

1.21E+03

  • VOL (B.2) cw B-3

Salem ODCM Rev. 5 12/21/88 Maximum Organ 1.67E-02

  • VOL
  • A Nb-95,GI-LLI Dmax = ---------------------------

(B.3) cw where:

Dmax

= maximum organ dose (mrem)

A Nb-95,GI-LLI = 1.51E+06, Gi-LLI ingestion dose conversion factor for Nb-95 (mrem/hr per uCi/ml)

Substituting the value for A Nb-95,GI-LLI the equation simplifies to:

2.52E+04

  • VOL Dmax = --------------

(B. 4) cw Tritium is not included in the limited analysis dose assessment for liquid releases, because the potential dose resulting from normal reactor releases is relatively negligible.

The average annual tritium release from each Salem Unit is approximately 350 curies.

The calculated total body dose from such a release is 2.4E-03 mrem/yr via the fish and invertebrate ingestion pathways.

This amounts to 0.08% of the design objective dose of 3 mrem/yr.

Furthermore, the release of tritium is a function of operating time and power level and is essentially unrelated to radwaste system operation.

B-4

Radio-nuclide Fe-59 Co-58 Co-60 Ag-110m Mn-54 Nb-95 Cs-137 Cs-134 Cr-51 Total Release (Ci)

N/D 1.54E+OO 4.22E-01 2.81E-03 1.05E-01 2.43E-03 3.01E-01 3.11E-01 N/D 2.69E+OO

  • less than 0.01 N/D = not detected Radio-nuclide Fe-59 Co-58 Co-60 Ag-110m Mn-54 Nb-95 Cs-137 Cs-134 Cr-51 Total Release (Ci)

N/D

1. 71 4.19E-01 N/D 1.20E-01 6.63E-03 3.31E-01 3.49E-01 3.03E-03 2.94E+OO
  • less than 0.01 N/D = not detected 1987 TB GI-LLI Dose Dose Frac.

Frac.

0.20 0.16 0.01 0.23 0.40 1987 TB Dose Frac.

0.32 0.10 0.02 0.20 0.41 0.47 0.34 0.04 0.06 0.09 GI-LLI Dose Frac.

0.44 0.06 0.05 0.41 Liver Dose Frac.

0.08 0.06 0.07 0.32 0.46 Liver Dose Frac.

0.13 0.04 0.10 0.29 0.46 Salem ODCM Rev. 5 Adult Dose Contributions Fish and Invertebrate Pathways Unit 1 Release (Ci) 2.40E-03 2.22 3.10E-01 N/D 1.90E-01 1.80E-02 3.60E-01 3.40E-01 6.00E-02 3.50E+OO 1986 TB GI-LLI Dose Dose Frac.

Frac.

0.01 0.25 0.10 0.02 0.14 0.38 Table B-2 0.02 0.42 0.07 0.06 0.42 0.01 Adult Dose Contributions Fish and Invertebrate Pathways Unit 2 Release (Ci) 4.00E-03 3.32.

3.80E*01 N/D 2.20E-01 2.50E-02 3.70E-01 N/D 9.50E-02 4.77E+OO B-5 1986 TB Dose Frac.

0.02 0.32 0.10 0.02 0.20 Gl-LLI Dose Frac.

0.03 0.44 0.06 0.05 0.41 Liver Dose Frac.

0.03 0.10 0.04 0.10 0.32 0.41 Liver Dose Frac.

0.05 0.13 0.04 0.10 0.29 Release (Ci) 1.40E-03 6.60E-01 6.50E-01 N/D 8.70E-02 1.30E-03 2.10E-01 1.60E-01 3.60E-02 1.80E+OO Release (Ci) 1.10E-03 8.40E-01 6.30E-01 N/D 1.10E-01 1.40E-02 2.30E-01 N/D 3.50E-02 2.04E+OO 12/21/88 Table B-1 1985 TB GI-LLI Dose Dose Frac.

Frac.

0.01 0.12 0.34 0.02 0.22 0.29 1985 TB Dose Frac.

0.01 0.14 0.30 0.02 0.23 0.04 0.36 0.42 0.08 0.09 GI-LLI Dose Frac.

0.02 0.23 0.21 0.05 0.48

Salem ODCM Rev. 5 12/21/88 APPENDIX C Technical Bases for Effective Dose Factors Gaseous Radioactive Effluent C-1

overview Salem ODCM Rev. 5 12/21/88 APPENDIX C Technical Bases for Effective Dose Factors -

Gaseous Radioactive Effluents The evaluation of doses due to releases of radioactive material to the atmosphere can be simplified by the use of effective dose transf~r factors instead of using dose factors which are radionuclide specific.

These effective factors, which can be based on typical radionuclide distributions of releases, can be applied to the total radioactivity released to approximate the dose in the environment (i.e., instead of having to perform individual radionuclide dose. analyses only a single multiplication (Keff, Meff

  • or Neff) times the total quantity of radioactive material released would be needed).

This approach provides a reasonable estimate of the actual dose while eliminating the need for a detailed calculation technique.

Determination of Effective Dose Factors Effective dose transfer factors are calculated by the following equations:

where:

Kef f K*

l f

  • l

=

=

=

(C.1) the effective total body dose factor due to gamma emissions from all noble gases released the total body dose factor due to gamma emissions from each noble gas radionuclide i released the fractional abundance of noble gas radionuclide i relative to the total noble gas activity C-2

Salem ODCM Rev. 5 12/21/88 (C.2) where:

(L + 1.1 M)eff

= the effective skin dose factor due to beta and gamma emissions from.all noble gases released where:

= the skin dose factor due to beta and gamma emissions from each noble gas radionuclide i released (C. 3 )*

= the effective air dose factor due to gamma emissions from all noble gases released

=

the air dose factor due to gamma emissions from each noble gas radionuclide i released (C. 4) where:

= the effective air dose factor due to beta emissions from all noble gases released

= the air dose factor due to beta emissions from each noble gas radionuclide i released Normally, it would be expected th~t past radioactive effluent data would be used for the determination of the effective dose factors.

However, the noble gas releases from Salem have been* maintained to such negligible quantities that the inherent variability in the data makes any meaningful evaluations difficult.

For the past years, the total noble gas releases have been limited to 1400 Ci for 1982, 900 Ci for 1983, 2,000 Ci for 1984, 2,800 Ci for 1985, and 2,700 Ci for 1986

  • Therefore, in order to provide a reasonable basis for the C-3

Salem ODCM Rev. 5 12/21/88 derivation of the effective noble gas dose factors, the primary coolant source term from ANSI N237-1976/ANS-18.l, "Source Term Specifications," has been used *as representing a typical distribution.

The effective dose factors as derived are presented in Table C-1.

Application To provide an additional degree of conservatism, a factor of 0.50 is introduced into the dose calculation process when the effective dose transfer factor is used.

This conservatism provides additional assurance that the evaluation of doses by the use of a single effective factor will not significantly underestimate any actual doses in the environment.

For evaluating compliance with the dose limits of Technical Specification 3.11.2.2, the following simplified equations may be used:

and where:*

3.17E-08

= --------

  • X/Q
  • Mef f
  • E Qi o.so 3.17E-08

= --------

  • X/Q
  • Neff
  • E Qi o.so (C.5)

(C. 6)

= air dose due to gamma emissions for the cumulative release of all noble gases (mrad)

= air dose due to beta emissions for the cumulative release of all noble gases (mrad)

= atmospheric dispersion to the controlling site boundary (sec/m3)

= 5.3E+02, effective gamma-air dose factor (mrad/yr per uCi/m3)

C-4

Salem ODCM Rev. 5 12/21/88 Neff

= _1.1E+03 I effective beta-air dose factor (mrad/yr per uci/m3)

Qi

=

cumulative release for all noble gas radionuclides (uCi) 3.17E-08 =

conversion factor (yr/sec) 0.50

=

conservatism factor to account for the variability in the effluent data Combining the constants, the dose calculation equations simplify to:

=

3.5E-05

  • X/Q *

(C.7) and

= 7.0E-05

  • X/Q *

(C.8)

The effective dose factors are used on a very limited basis for the purpose of fac.ilitating the timely assessment of radioactive effluent releases, particularly during periods of computer malfunction where a detailed dose assessment may be unavailable

  • C-5

Noble Gases - Total Body and Skin Radionuclide Kr-85 Kr-88 Xe-133m Xe-133 Xe-135 Total Noble Gases -

Radionuclide Kr-85 Kr-88 Xe-133m Xe-133 Xe-135 Total Air f.*

1 0.01 0.01 0.01 0.95 0.02 f.*

1 0.01 0.01 0.01 0.95 0.02 Table C-1 Effective Dose Factors Total Body Effective Dose Factor Keff (mrem/yr per uCitm3)

Salem ODCM Rev. 5 Skin Effective Dose Factor CL+ 1.1 M>eff Cmrem/yr per uCitm3) 1.4E+01 1.5E+02 1.9E+02 2.5E+OO 1.4E+01 3.0E+02 6.6E+02 3.6E+01 7.9E+01 4.8E+02 9.6E+02 I

Ganma Air Effective Beta Air Effective Dose Factor Dose Factor Mef f Cmrad/yr per uCi/m3)

Neff Cmrad/yr per uCi/m3)


~------

2.0E+01 1.5E+02 2.9E+01 3.3E+OO 1.SE+01 3.4E+02 1.0E+03 3.8E+01 4.9E+01 5.3E+02 1.1E+03

  • Based on Noble gas distribution from ANSI N237-1976/ANSI-18.1, "Source Term Specif i cati ons. 11 C-6 12/21/88

Salem ODCM Rev. 5 12/21/88 APPENDIX D Technical Basis for Effective Dose Parameter Gaseous Radioactive Effluent D-1

Salem ODCM Rev. 5 12/21/88 APPENDIX D Technical Basis for Effective Dose Parameter Gaseous Radioactive Effluent Releases The pathway dose factors for the controlling infant age group were evaluated to determine the controlling pathway, organ and radionuclide.

This analysis was performed to provide a simplified method for determining compliance with Technical Specification 3.11.2.3 For the infant age group, the controlling pathway is the grass-milk-cow (g/m/c) pathway.

An infant receives a greater radiation dose from the g/m/c pathway than any other pathway.

Of this g/m/c pathway, the maximum exposed organ including the total body, is the thyroid, and the highest dose contributor is radionuclide I-131.

The results for this evaluation are presented in Table D-1.

For purposes of simplifying the details of the dose calculation process, it is conservative to identify a controlling, dose significant organ and radionuclide and limit the calculation proc~ss to the use of the dose conversion factor for the organ and radionuclide. Multiplication of the total release (i.e. cumulative activity for all radionuclides) by this dose conversion factor provides for a dose calculation method that is simplified while also being conservative.

For the evaluation of the dose commitment via a controlling pathway D-2

Salem ODCM Rev. 5 12/21/88 and age group, it is conservative to use the infant, g/m/c, thyroid, I-131 pathway dose factor (1.675E12 m2 mrem/yr per uCi/sec).

By

\\

this approach, the maximum dose commitment will be overestimated since I-131 has the highest pathway dose factor of all radionuclides evaluated.

For evaluating compliance with the dose limits of Technical Specification 3.11.2.3, the following simplified equation may be used:

where:

Dmax

=

3.17E-8

  • w
  • RI-131
  • E Qi Dmax

=

maximum organ dose (mrem)

W

=

atmospheric dispersion parameters to the controlling location(s) as identified in Table 3.2-4.

X/Q

=

atmospheric dispersion for inhalation pathway and H-3 dose contribution via other pathways (sec/m3)

D/Q =

  • atmospheric deposition for vegetation, milk and ground plane exposure pathways (m-2)

Qi 3.17E-8 RI-131

=

cumulative release over the period of interest for radioiodines and particulates

= conversion factor (yr/sec)

= I-131 dose parameter for the thyroid for the identified controlling pathway

= 1.675E12 (m2 mrem/yr per uci/sec), infant thyroid dose parameter with the cow-milk-grass pathway controlling The ground plane exposure and inhalation pathways need not be considered when the above simplified calculation method is used because of the overall negligible contribution of these pathways to the total thyroid dose.

It is recognized that for some particulate D-3

Salem ODCM Rev. 5 12/21/88 (e.g., Co-60 and Cs-137), the ground exposure pathway may represent a higher dose contribution than either the vegetation or milk pathway.

However, use of the I-131 thyroid dose parameter for all radionuclides will maximize the organ dose calculation, especially considering that no other radionuclide has a higher dose parameter for any organ via any pathway than I-131 for the thyroid via the milk pathway (see Table D-1).

  • The location of exposure pathways and the maximum organ dose calculation may be based on the available pathways in the surrounding environment of Salem as identified by the annual land-use census (Technical Specification 3.12.2).

Otherwise, the dose will be evaluated based on the predetermined controlling pathways as identified in Table 2-4.

D-4

Target Organs Total Body Liver Thyroid Kidney Lung GI-LLI Salem ODCM Rev. 5 12/21/88 Table D-1 Infant Dose Contributions Fraction of Total Organ and Body Dose PATHWAYS Grass-Cow-Milk 0.02 0.23 0.59 0.02 0.01 0.02 Fraction of Dose Contribution by Pathway Pathway Grass-Cow-Milk 0.92 Ground Plane 0.08 Inhalation D-5 Ground Plane 0.15 0.14 0.15 0.15 0.02 0~15

Salem ODCM Rev. 5 12/21/88 Appendix E Radiological Environmental Monitoring Program Sample Type, Location and Analysis E-1

Salem ODCM Rev. 5 12/20/88 APPENDIX E SAMPLE DESIGNATION Samples are identified by a three part code.

The tirst two letters are the power station identification code, in this case "SA".

The next three letters are for the media sampled.

AIO = Air Iodine IDM = Immersion Dose (TLD)

APT = Air Particulates MLK = Milk ECH = Hard Shell Blue Crab PWR* = Potable Water (Raw)

ESF = Edible Fish PWT = Potable Water (Treat~d)

ESS = Sediment RWA = Rain Water (Precipitation)

FPB = Beef SWA = Surface Water FPL = Green Leafy Vegetables VGT = Fodder Crops (Various)

FPV = Vegetable (Various)

WWA = Well Water GAM = Game The last four symbols are a location code based on direction and distance from the site.

Of these, the tirst two represent each of the sixteen angular sectors of 22.5 degrees centered about the reactor site.

Sector one is divided evenly by the north axis and other sectors are numbered in a clockwise direction; i.e., 2=NNE, 3=NE, 4=ENG, etc.

The next digit is a letter which represents the radial distance from the plant:

s = On-site location E = 4-5 miles off-site A = 0-1 miles off-site F = 5-10 miles off-site B = 1-2 miles off-site G = 10-20 miles off-site c = 2-3 miles off-site H = >20 miles off-site D = 3-4 miles off-site The last number is the station numerical designation within eah sector and zone; e.g., 1,2,3, *..

For example, the designation SA-WWA-5Dl would indicate a sample in the SGS program (SA),

consisting of well water (WWA), which had been collected in sector number 5, centered at 90' (due east) with respect to the reactor site at a radial distance of 3 to 4 miles off-site, (therefore, radial distance D).

The number 1 indicates that this is sampling station #1 in that particular sector

  • E-2

Salem ODCM Rev. 5 12/20/88 SAMPLING LOCATIONS All sampling locations and specific information about the individual locations are given in Table E.

Maps E-1 and E-2 show the locations of sampling stations with respect to the site.

STATION CODE 2S2 3S3 5Sl 6S2 7Sl lOSl llSl llAl 15Al 16Al 12Cl 4D2 5Dl lODl llDl 14Dl 2El TABLE E-1 STATION LOCATION 0.4 mi. NNE of vent 700 ft. NNE of vent; fresh water holding tank 1.0 mi. E of vent; site access road 0.2 mi. ESE of vent; observation building 0.12 mi. SE of vent; station personnel gate 0.14 mi. SSW of vent; site shoreline U.09 mi. SW of vent; site shoreline 0.2 mi. W of vent; outfall area 0.3 mi. NW of vent; cooling tower blowdown discharge line 0.7 mi. NNW of vent; south storm drain discharge line 2.5 mi. WSW of vent; west bank of Delaware River SAMPLE TYPES IDM WWA AIO,APT,IDM IDM IDM IDM IDM ECH,ESF,ESS, SWA ESS ESS ECH,ESF,ESS, SWA 3.7 mi. ENE of vent; Alloway Creek Neck Road IDM 3.5 mi. E of vent; local farm AIO,APT,IDM, WWA 3.9 mi. SSW of vent; Taylor's Bridge Spur IDM 3.5 mi. SW of vent GAM 3.4 mi. WNW of vent; Bay View, Delaware IDM 4.4 mi. NNE of vent; local farm IDM E-3

v STATION CODE 3El 3E2 7El 9El 11E2 12El 13El 13E3 16El lFl Salem ODCM Rev. 5 12/20/88 TABLE E-1 (Cont'd)

STATION LOCATION 4.1 mi. NE of vent; local farm 5.7 mi. NE of vent; local farm 4.5 mi. SE of vent; l mi. W of Man Horse Creek 4.2 mi. S of vent 5.0 mi. SW of vent 4.4 mi. WSW of vent; Thomas Landing 4.2 mi. W of vent; Diehl House Lab 4.9 mi. W of vent; local farm 4.1 mi. NNW of vent; Port Penn 5.8 mi. N of vent; Fort Elfsborg SAMPLE TYPES FPB,FPV,GAM, IDM,VGT,WWA FPV ESF,ESS,SWA IDM IDM IDM IDM VGT AIO,APT,IDM AIO,APT, IDM 1F2 7.1 mi. N of vent; midpoint of Delaware River SWA 1F3 2F2 2F3 2F4 2F5 2F6 2F7 3F2 3F3 5Fl 5.9 mi. N of vent; local farm 8.7 mi. NNE of vent; Salem Substation 8.0 mi. NNE of vent; Salem Water Company 6.3 mi. NNE of vent; local farm 7.4 mi. NNE of vent; Salem High School 7.3 mi. NNE of vent; Southern Training Center 5.7 mi. NNE of vent; local farm 5.1 mi. NE of vent; Hancocks Bridge Municipal Building 8.6 mi. NE of vent; Quinton Township School 6.5 mi. E of vent E-4 FPL,FPV AIO,APT,IDM, RWA PWR, PWT

.F'PV IDM IDM MLK,VGT IDM IDM 1',PV, IDM

STATION CODE 5F2 6Fl 7F2 10F2 llFl 11F3 12Fl 13F2 13F3 13F4 14Fl 14F2 14F3 15F3 16Fl 16F2 lGl 1G3 2Gl 3Gl lOGl Salem ODCM Rev. 5 12/20/88 TABLE E-1 (Cont'd)

STATION LOCATION SAMPLE TYPES 7.0 mi. E of vent; local farm VGT 6.4 mi. ESE of vent; Stow Neck Road IDM 9.1 mi. SE of vent; Bayside, New Jersey IDM 5.8 mi. SSW of vent IDM 6.2 mi. SW of vent; Taylor's Bridge Delaware IDM 5.3 mi. SW of vent; Townsend, Delaware MLK,VGT 9.4 mi. WSW of vent; Townsend Elementary IDM School 6.5 mi. W of vent; Odessa, Delaware 9.3 mi. W of vent; Redding Middle School, Middletown, Delaware 9.8 mi. W of vent; Middletown, Delaware 5.5 mi. WNW of vent; local farm 6.6 mi. WNW of vent; Boyds Corner 5.4 mi. WNW of vent; local farm 5.4 mi. NW of vent 6.9 mi. NNW of vent; C&D Canal 8.1 mi. NNW of vent; Delaware City Public School 10.3 mi. of N of vent; local farm 19 mi. N of vent; Wilmington, Delaware 12 mi. NNE of vent; Mannington Township, NJ 17 mi. NE of vent; local farm 12 mi. SSW of vent; Smyrna, Delaware E-5 IDM IDM IDM MLK,VGT IDM

, FPV IDM ESS,SWA IDM F'PV IDM 1'""'PV IDM,MLK,VGT IDM

v STATION CODE 16Gl Salem ODCM Rev. 5 12/20/88 TABLE E-1 (Cont'd)

STATION LOCATION 15 mi. NNW of vent; Greater Wilmington Airport SAMPLE TYPES IDM 3Hl 32 mi. NE of vent; National Park, New Jersey IDM 3H3 110 mi. NE of vent; Research and Testing AIO,APT,IDM Laboratory 3H5 25 mi. NE of vent; local farm FPL,FPV E-6

Sample Air Particulate Air Iodine Crab and Fish Sediment Direct Milk Salem ODCM Rev. 5 12/20/88 SAMPLE COLLECTION AND ANALYSIS Collection Method Continuous low volume air sampler.

Sample collected every week along with the filter change.

A TEDA impregnated charcoal cartridge is connected to air particulated air sampler and is collected weekly at filter change.

Two batch samples are sealed in a plastic bag or jar and frozen semi-annually or when in season.

A sediment sample is taken semi-annually.

2 TLD's will be collected from each location quarterly.

Sample of fresh milk is collected for each farm semi-monthly when cows are in pasture, monthly at other times.

E-7 Analysis Gross Beta analysis on each weekly sample.

Gamma spectrometry shall be performed if gross beta exceeds 10 times the yearly mean of the control station value.

As well one sample is analyzed >24 hrs after sampling to allow for radon and thoron daughter decay.

Gamma isotopic analysis on quarterly composites.

Iodine 131 analysis are performed on each weekly sample.

Gamma* isotopic analysis of edible portion on collection Gamma isotopic analysis semi-annually.

Gamma dose quarterly Gamma isotopic analysis and I-131 analysis on each sample on collection.

Salem ODCM Rev. 5 12/20/88 SAMPLE COLLECTION AND ANALYSIS (Cont'd)

Sample Water (Rain, Potable, Surface)

Collection Method Sample to be collected monthly providing winter icing conditions allow.

E-8 Analysis Gamma isotopic monthly H-3 on quarterly surf ace sample, monthly on ground water sample.

\\

\\

' \\

\\

\\