Forwards Reactor Containment Bldg Integrated Leak Rate Test,Feb 1991 Special Rept. Conditions Met Containment Leakage Requirements
ML18057A922
Person / Time
Site: Palisades Entergy icon.png
Issue date: 05/17/1991
From: Slade G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18057A923 List:
References
NUDOCS 9105310094
Download: ML18057A922 (1)


Text

..

consumers Power GB Slade General Manager POWERINli MICHlliAN~S PROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 May 17, 1991 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST - SPECIAL REPORT During the 1990 combined RefueJing Outage and Steam Generator Replacement, Palisades completed a full pressure Type A Containment Integrated Leak Rate test. For this test, the mass point method of analysis was used as allowed by 10 CFR 50, Appendix J. Both the "as-found" and "as-left" conditions met the containment leakage requirements of the Palisades Technical Specifications and 10 CFR 50, Appendix J.

Attached is a special report, Reactor Containment Building Integrated Leak Rate Test - February 1991, which summarizes the methods used and the results.

This report is submitted in accordance with Technical Specification 4.5.1.e and 10 CFR 50, Appendix J.

~

GBSlade General Manager CC Administrator, Region III, USNRC NRC Resident Inspector, Palisades 9105310094 6~8&6~55 PDR ADOC~ PDR p