MONTHYEARL-23-267, Submittal of Discharge Monitoring Report (Npdes), Permit No. PA00256152023-12-18018 December 2023 Submittal of Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-229, Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports2023-11-29029 November 2023 Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports L-23-247, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-11-17017 November 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-227, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 20232023-10-20020 October 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 2023 L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA00256152023-09-14014 September 2023 Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615 L-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-179, Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-07-18018 July 2023 Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-165, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-06-26026 June 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-139, Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report2023-06-13013 June 2023 Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report L-23-055, Submittal of the Updated Final Safety Analysis Report, Revision 342023-05-23023 May 2023 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-137, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-05-18018 May 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-125, Cycle 24 Core Operating Limits Report2023-05-17017 May 2023 Cycle 24 Core Operating Limits Report L-23-132, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-10010 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-129, Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations2023-05-0505 May 2023 Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations L-23-115, Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological2023-04-27027 April 2023 Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological L-23-126, Discharge Monitoring Report (Npdes), Permit No. PA00256152023-04-22022 April 2023 Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-053, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-04-14014 April 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-058, 180-Day Steam Generator Tube Inspection Report2023-03-27027 March 2023 180-Day Steam Generator Tube Inspection Report L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-036, Report of Facility Changes, Tests and Experiments2023-03-13013 March 2023 Report of Facility Changes, Tests and Experiments L-23-086, Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0404 March 2023 Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-087, Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027)2023-03-0404 March 2023 Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027) L-23-073, Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0101 March 2023 Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-23-064, Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-02-21021 February 2023 Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-193, Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H2023-02-14014 February 2023 Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H L-22-286, Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time2023-02-14014 February 2023 Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time L-23-032, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 20222023-01-23023 January 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 2022 L-22-281, Discharge Monitoring Report (NPDES) Permit No. PA00256152022-12-16016 December 2022 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-246, Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO2022-12-0707 December 2022 Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO L-22-217, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-11-21021 November 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-226, Emergency Preparedness Plan2022-11-0404 November 2022 Emergency Preparedness Plan L-22-222, Cycle 29-1 Core Operating Limits Report2022-10-31031 October 2022 Cycle 29-1 Core Operating Limits Report L-22-228, Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2022-10-26026 October 2022 Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-22-200, Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage2022-10-21021 October 2022 Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage L-22-232, Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes2022-10-21021 October 2022 Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes L-22-238, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-10-20020 October 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-227, Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins2022-10-0303 October 2022 Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins L-22-219, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-09-26026 September 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-204, Submittal of Evacuation Time Estimates2022-09-0707 September 2022 Submittal of Evacuation Time Estimates L-22-137, Request for Fire Protection Program Changes2022-09-0606 September 2022 Request for Fire Protection Program Changes L-21-238, License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident2022-08-31031 August 2022 License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident L-22-188, Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage2022-08-22022 August 2022 Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage L-22-191, Spent Fuel Storage Cask Registration2022-08-17017 August 2022 Spent Fuel Storage Cask Registration 2023-09-14
[Table view] |
Text
Beaver Valley Power Station FirstEnergy Nuclear Operating Company P.O. Box4 Shippingport, PA 15077 Richard D. Bologna 724-682-5234 Site Vice President Fax: 724-643-8069 December 14, 2017 L-17-351 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-001
SUBJECT:
Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Anchor Darling Double Disc Gate Valve Information and Status In Reference 1, the Nuclear Energy Institute (NEI) provided the Nuclear Regulatory Commission (NRC) a resolution plan for the U.S. Nuclear Industry to address the known Anchor Darling Double Disk Gate Valve (ADDDGV) issues. Reference 2 indicated each utility will provide a listing of their ADDDGV population with active safety functions along with relevant valve information, including the results of susceptibility evaluations, repair status, and a repair schedule for each susceptible valve not yet repaired. This letter serves to provide this information for Beaver Valley Power Station, Unit No. 1. Beaver Valley Power Station, Unit No. 2, has no ADDDGVs.
The Attachment to this letter contains the following information for each ADDDGV.
- Plant Name, Unit, and Valve ID
- Valve Functional Description
- Active Safety Function (open, close, both)
- Are multiple design basis post-accident strokes required? (yes/no)
- Expert Panel Risk Ranking (high, medium, low)
- Result of susceptibility evaluation (susceptible or not susceptible)
- Is the susceptibility evaluation in general conformance with TP16-1-112, Revision 4? (Reference 3)
- Does the susceptibility evaluation rely on thread friction? If yes, was the coefficient of friction (COF) greater than 0.1 0? For cases where thread-friction was relied upon, information is provided whether the COF was above or below 0.1.
Beaver Valley Power Station, Unit Nos. 1 and 2 L-17-351 Page 2
- Was an initial stem-rotation check performed? If yes, include rotation criteria (i.e., less than or equal to 1O degrees or less than or equal to 5 degrees).
- Was the diagnostic test data reviewed for failure precursors described in TP16-1-112, Revision 4? (Reference 3)
- The valve's repair status (i.e., repaired or not repaired)
- A repair schedule for each susceptible valve By letter dated August 29, 2017 (ADAMS Accession No. ML17243A134), FirstEnergy Nuclear Operating Company identified "High Significance" motor-operated valves (MOVs) and provided commitments related to the repair schedule for those MOVs.
Further analysis of the identified MOVs was performed in accordance with the guidance provided in Reference 3. Based on the analysis results, the MOVs are now classified as not susceptible, and the Attachment to this letter reflects this change. Because no repair schedule is necessary, the commitments identified in the August 29, 2017 letter are hereby rescinded.
There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager - Fleet Licensing, at 330-315-6810.
Respectfully,
,\ () j/j(l l L v_v-_ ---
Richard D. Bologna
Attachment:
Beaver Valley Power Station ADDDGV Listing
References:
- 1. Letter from Greg Krueger (NEI) to John Lubinski (NRC), Anchor Darling Double Disc Gate Valve Industry Resolution Plan Update (Project 689), dated August 4, 2017.
- 2. Letter from Joseph Pollock (NEI) to Brian Holian (NRC), NSIAC Concurrence on Anchor Darling Double Disc Gate Valve Industry Response Actions (Project 689),
dated October 26, 2017.
- 3. BWROG Topical Report TP16-1-i 12, Revision 4, Recommendations to Resolve Flowserve 10CFR Part 21 Notification Affecting Anchor Darling Double Disc Gate Valve Wedge Pin Failures, dated August 2017.
cc: NRC Region I Administrator NRC Resident Inspector NRR Project Manager Director BRP/DEP Site BRP/DEP Representative
Attachment L-17-351 Beaver Valley Power Station ADDDGV Listing Is the Does the susceptibility Was an initial stem-susceptibility Valve Active Are multiple design Expert Result of evaluation rely on thread rotation check Was the diagnostic test data Plant Valve Size evaluation in Valve repair Unit Valve ID System Functional Safety basis post-accident Panel Risk susceptibility friction? performed? reviewed for failure precursors Name (inches) general status (7)
Description Function strokes required? Ranking evaluation If yes, was the COF greater If yes, include rotation described in TP16-1-112R4?
conformance with than 0.10? criteria TP16-1-112R4? (A)
(Open, (High, (No), (No),
(susceptible or (repaired or Close, Medium, (Yes/No) (Yes, >0.10), (Yes, 10 deg.), (Yes/ No)
(Yes/No) not susceptible) not repaired)
Both) Low) (Yes, 0.10) (Yes, 5 deg.)
Diesel Generator (DG)
Heat Exchanger Inlet River Beaver River Water (RW)
Valley 1 MOV-1RW-113A Water Supply Header 4 Open No (4) Medium Not Susceptible (1) Yes No Yes, 10 deg. Yes Not repaired DG Heat Exchanger Inlet Beaver River RW Supply Valley 1 MOV-1RW-113B Water Header 4 Open No (4) Medium Not Susceptible (1) Yes No Yes, 10 deg. Yes Not repaired DG Heat Exchanger Inlet Beaver River RW Supply Valley 1 MOV-1RW-113C Water Header 4 Open No (4) Medium Not Susceptible (1) Yes No Yes, 10 deg. Yes Not repaired DG Heat Exchanger Inlet Beaver River RW Supply Valley 1 MOV-1RW-113D1 Water Header 4 Open No (4) Medium Not Susceptible (1) Yes No Yes, 10 deg. Yes Not repaired Low Head Safety Injection (LHSI) to Beaver Safety Charging Pumps Valley 1 MOV-1SI-863A Injection Supply Valve 6 Open No (5) Medium Not Susceptible (2) Yes No Yes, 10 deg. Yes Not repaired LHSI to Beaver Safety Charging Pumps Valley 1 MOV-1SI-863B Injection Supply Valve 6 Open No (5) Medium Not Susceptible (2) Yes No Yes, 10 deg. Yes Not repaired LHSI to Reactor Beaver Safety Coolant System Valley 1 MOV-1SI-890A Injection (RCS) Hot Legs 10 x 8 x 10 Open No (6) Low Not Susceptible (3) Yes Yes, > 0.10 Yes, 5 deg. Yes Not repaired Beaver Safety LHSI to RCS Valley 1 MOV-1SI-890B Injection Hot Legs 10 x 8 x 10 Open No (6) Low Not Susceptible (3) Yes Yes, > 0.10 Yes, 5 deg. Yes Not repaired Beaver Safety LHSI to RCS Valley 1 MOV-1SI-890C Injection Cold Legs 10 x 8 x 10 Close No (6) High Not Susceptible (3) Yes Yes, > 0.10 Yes, 10 deg. Yes Not repaired (A)
Applied Wedge Pin Torque must bound anticipated design basis operating torque requirements and current maximum total torque.
(1) MOV-1RW-113A, 113B, 113C, and 113D1: wedge pin shear capability exceeds the design basis operating torque requirements and current maximum total torque.
(2) MOV-1SI-863A and 863B: wedge pin shear capability exceeds the design basis operating torque requirements and current maximum total torque.
(3) MOV-1SI-890A, 890B, and 890C: wedge pin shear capability including thread friction exceeds the design basis operating torque requirements and current maximum total torque.
(4) MOV-1RW-113A, 113B, 113C, and 113D1: multiple design basis post-accident strokes are not required; however, as a contingency the valves could be stroked to secure the associated diesel generator which has auto-started from a safety injection signal and is running unloaded.
(5) MOV-1SI-863A and 863B: multiple design basis post-accident strokes are not required; however, as a contingency the valves could be stroked to prevent damage to high head safety injection (HHSI) charging pumps if a loss of offsite power occurs with the plant in SI recirculation alignment.
(6) MOV-1SI-890A, 890B, and 890C: multiple design basis post-accident strokes are not required; however, as a contingency the valves could be stroked to isolate a loss-of-coolant accident (LOCA) outside containment.
(7) There are no susceptible valves; therefore, a repair schedule is not necessary.