ML17312A997

From kanterella
Jump to navigation Jump to search

Forwards Memo to Commission Re Resolution of SFP Safety Issues,For Info
ML17312A997
Person / Time
Site: Palo Verde  
Issue date: 10/09/1996
From: Clifford J
NRC (Affiliation Not Assigned)
To: James M. Levine
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
References
TAC-M88094, NUDOCS 9610110373
Download: ML17312A997 (7)


Text

T I

~P,R RE00, I'

I n0 0

++*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 October 9, 1996 Mr. James M. Levine Senior Vice President, Nuclear Arizona Public Service Company Post Office Box 53999 Phoenix, Arizona 85072-3999

SUBJECT:

RESOLUTION OF SPENT FUEL STORAGE POOL SAFETY ISSUES:

ISSUANCE OF FENM. REPORT, ARIZONA PUBLIC SERVICE

COMPANY, PALO VERDE NUCLEAR GEHERATING STATION, UNIT NOS.

1, 2, AND 3 (TAC NO. M88094)

Dear Mr. Levine:

The Nuclear Regulatory Commission staff recently completed a detailed review of spent fue1 storage pool safety issues.

The results of the staff's review are documented in a report to the Commission which is enclosed for your information.

In the report, the staff concludes that existing structures,

systems, and components related to the storage of irradiated fuel provide adequate protection of public health and safety.

Notwithstanding this finding, the staff has also identified certain design features that reduce the reliability of spent fuel pool decay heat removal, increase the potential for loss of spent fuel coolant inventory, or increase the potential for consequential loss of essential safety functions at an operating reactor.

The staff intends to conduct plant-specific regulatory analyses to evaluate potential safety enhancement backfits pursuant to 10 CFR

50. 109(a)(3) at a number of operating plants that possess one or more of these design features.

Although Palo Verde Units 1, 2, and 3 are not identified for a plant-specific safety enhancement backfit analysis by the staff, it is requested that you review the enclosed report for applicability to your facility and consider

actions, as appropriate, related to the design of spent fuel pool decay heat removal systems at your facility.

This letter does not require any response.

96iOii0373 9bi009 PDR ADOCK 05000528 P

PDR SIMKKCRT~~V

I I

J I

I 1

el ll p

Mr. James M. Levine October 9,

1996 If you have any questions, please contact me at (301) 415-1352.

Sincerely, ORIGINAL SIGNED BY James W. Clifford, Senior Project Manager Project Directorate IV-2 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos.

STN 50-528, STN 50-529, and STN 50-530

Enclosure:

Memo to the Commission, from J. Taylor, "Resolution'f-Spent Fuel Storage Pool Action Plan, Issues,"

dated July 26, 1996

'c w/encl:

See next page DISTRIBUTION:

(w/enclosure)

~Docket Fil~e,

ACRS, TWFN PUBLIC PDIV-2 Reading JCl ifford (w/o enclosure)

JRoe

OGC, 015818 EAdensam
KPerkins, WCFO WBateman
JDyer, RIV EPeyton
DKirsch, WCFO JShea KJohnston, RIV/SRI DOCUMENT NAME: PV88094. INT OFC PD IV-2/PM PDIV-2/LA NAME JCli ord:ye E ey o DATE 8/ 9/96 0/9/96 OFFICIAL RECORD COPY

Mr. James M. Levine October 9, 1996 If you have any questions, please contact me at (301) 415-1352.

Sincerely, J

mes W. Clifford, Senior Project Manager Project Directorate IV-2 Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos.

STN 50-528, STN 50-529, and STN 50-530

Enclosure:

Memo to the Commission, from J. Taylor, "Resolution of Spent Fuel Storage Pool Action Plan Issues,"

dated July 26, 1996 cc w/encl:

See next page

tl

Hr. James M. Levine cc w/encl:

Hr. Steve Olea Arizona Corporation Gommission 1200 W. Washington Street Phoenix, Arizona

&5007 Douglas Kent Porter Senior Counsel Southern California Edison Company Law Department, Generation Resources P.O.

Box &00

Rosemead, California

.91770 Senior Resident Inspector 1JSNRC P. 0.

Box 40 Buckeye, Arizona 85326 Regional Administrator, Region IV U. S. Nuclear Regulatory Commission Harris Tower

& Pavil 1ion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76ml-8064

Chairman, Board of Supervisors ATTN:

Chairman 301 W. Jefferson, 10th Floor Phoenix, Arizona 85603 Hr. Aubrey V. Godwin, Director Arizona Radiation Regulatory Agency 4814 South 40 Street Phoenix, Arizona 85040 Hs. Angela K. Krainik, Manager Nuclear Licensing Arizona Public Service Company P.O.

Box 52034 Phoenix, Arizona 85072-2034 Hr. John C. Horne, Vice President Power Supply Palo Verde Services 2025 N. Third Street, Suite 220 Phoenix, Arizona 85004

4 1