Mr. John R. McGaha, Jr.

October 8, 1996 Vice Presid::nt - Operations Entergy Operatiens, Inc.

River Bend Station P. O. Box 220 St. Francisville, LA 70775

SUBJECT:

RESOLUTION OF SPENT FUEL STORAGE P00L SAFETY ISFJES:

ISSUANCE OF FINAL REPORT, RIVER BEND STATION (TAC N0. M88094)

Dear Mr. McGaha:

The Nuclear Regulatory Commission staff recently completed a detailed review of spent fuel storage pool safety issues.

The results of the staff's review are documented in a report to the Commission, which is enclosed for your information.

In the report, the staff concludes that existing structures, systems, and components related to the storage of irradiated fuel provide adequate protection of public health and safety.

Notwithstanding this finding, the staff has also identified certain design features that reduce the reliability of spent fuel pool decay heat removal, increase the potential for loss of spent fuel coolant inventory, or increase the potential for consequential loss of essential safety functions at an operating reactor.

The staff intends to conduct plant-specific regulatory analyses to evaluate potential safety enhancement backfits pursuant to 10 CFR 50.109(a)(3) at a number of operating plants that possess one or more of these design features.

Although River Bend Station, Unit 1 is not identified for a plant-specific safety enhancement backfit analysis by the staff, it is requested that you review the enclosed report for applicability to your facility and consider actions, as appropriate, related to the design of spent fuel pool decay heat removal systems at your facility. This letter does not require any response.

If you have any questions regarding this matter, please do not hesitate to contact me at 301-415-1031.

Sincerely, ORIGINAL SIGNED BY:

David L. Wigginton, Senior Project Manager Project Directorate IV-1 1

Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation Docket Nos. 50-458

Enclosure:

Memo to the Commission, from J. Taylor,

" Resolution of Spent Fuel Storage Pool 1

Action Plan Issues," dated July 26, 1996 cc w/ encl:

See next page

}

}

,M i

DISTRIBUTION: ' Docket OGC PUBLIC JRoe JShea GHill (4)

ACRS DWigginton JDyer, RIV PDIV-1 r/f

-Piress ey WBeckner EAdensam (EGA1) l Document Name:

RB88094.LTR 0FC PM/PD4-1,b./

LA/PD4fl NAME DWiacin N M sNNder g hk

[d ff/96 NRC W C DATE h/R/96

/

COPY NIS/N0 YESdI0')

I)FFICIAL RECORD COPY 9610110005 96100s

~

PDR ADOCK 05000458 P

PDR

m e uc I

ef*-

lt UNITED STATES l

[

j NUCLEAR REGULATORY COMMISSION

't WASHINGTON D.C. 20666-0001

%*****/

October 8, 1996 i

Mr. John R. McGaha, Jr.

Vice President - Operations Entergy Operations, Inc.

River Bend Station P. O. Box 220 St. Francisville, LA 70775

SUBJECT:

RESOLUTION OF SPENT FUEL STORAGE POOL SAFETY JSSUES:

ISSUANCE OF FINAL REPORT, RIVER BEND STATION (TAC NO. M88094)

Dear Mr. McGaha:

The Nuclear Regulatory Commission staff recently completed a detailed review of spent fuel storage pool safety issues. The results of the staff's review are documented in a report to the Commission, which is enclosed for your information.

In the report, the staff concludes that existing structures, systems, and components related to the storage of irradiated fuel provide adequate protection of public health and safety.

Notwithstanding this finding, the staff has also identified certain design features that reduce the reliability of spent fuel pool decay heat removal, increase the potential for loss of spent fuel coolant inventory, or increase the potential for consequential loss of essential safety functions at an operating reactor. The staff intends to conduct plant-specific regulatory analyses to evaluate potential safety enhancement backfits pursuant to 10 CFR 50.109(a)(3) at a number of operating plants that possess one or more of these design features.

Although River Bend Station, Unit 1 is not identified for a plant-s)ecific safety enhancement backfit analysis by the staff, it is requested t1at you review the enclosed report for applicability to your facility and consider actions, as appropriate, related to the design of spent fuel pool decay heat removal systems at your facility. This letter does not require any response.

If you have any questions regarding this matter, please do not hesitate to contact me at 301-415-1031.

Sincerely, l

A David L.

4 nton, Senior Project Manager Project Directorate IV-1 Division of Reactor Projects III/IV

(

Office of Nuclear Reactor Regulation i

Docket Nos. 50-458 l

l

Enclosure:

Memo to the Commission, from J. Taylor, i

" Resolution of Spent Fuel Storage Pool Action Plan Issues," dated July 26, 1996 cc w/ encl:

See next page

s aseg i

i Mr. John R. McGaha Entergy Operations, Inc.

River Bend Station cc:

Winston & Strawn Executive Vice President and 1400 L Street, N.W.

Chief Operating Officer Washington, DC 20005-3502 Entergy Operations, Inc.

{

P. O. Box 31995 i

Manager - Licensing Jackson, MS 39286 Entergy Operations, Inc.

River Bend Station General Manager - Plant Operations 2

P. O. Box 220 Entergy Operations, Inc.

St. Francisville, LA 70775 River Bend Station i

P. O. Box 220 i

Director St. Francisville, LA 70775 i

Joint Operations Cajun 10719 Airline Highway Director - Nuclear Safety P. O. Box 15540 Entergy Operations, Inc.

Baton Rouge, LA 70895 River Bend Station P. O. Box 220 Senior Resident Inspector St. Francisville, LA 70775 P. O. Box 1050 St. Francisv111e, LA 70775 Vice President - Operations Support Entergy Operations, Inc.

President of West Feliciana P. O. Box 31995 Police Jury Jackson, MS 39286-1995 P. O. Box 1921 St. Francisville, LA 70775 Attorney General State of Louisiana Regional Administrator, Region IV P. O. Box 94095 U.S. Nuclear Regulatory Commission Baton Rouge, LA 70804-9095 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011 Wise, Carter, Child & Caraway P. O. Box 651 Ms. H. Anne P1ettinger Jackson, MS 39205 3456 Villa Rose Drive Baton Rouge, LA 70806 Vice President & Controller Cajun Electric Power Cooperative Administrator 10719 Airline Highway Louisiana Radiation Protection Division P.O. Box 15540 P. O. Box 82135 Baton Rouge, LA 70895 Baton Rouge, LA 70884-2135

_ _ - _ -.