REGULA( INFORMATION DISTRIBUTIO 'YSTEM (BIDS)

ACCEPS1ZIN NBR: 8808890079 DOC. DATE: 88/08/19 NOTARIZED: NO DOCKET 0 FACIL: 50-397 WPPSS Nuclear Progecti Unit 2i Washington Public Poee 05000397 AUTH. NAME AUTHOR AFFILIATION SORENSENS Q. C. Washington Public Foujer Supply System RECIP. NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Application for amend to License NPF-21I one time only temporary amend to Tech Specs 3. 9. 7 (crane travel-spent fuel storage pool) under emergency circumstances. Requests addi clarif ication.

DISTRIBUTION CODE: A001D COPIES RECEIVED: LTR I ENCL ] SIZE:

TITLE: OR Submittal: General Distribution NOTES:

RECIPIENT COP IES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD5 L* 1 0 PD5 PD 5 5 SAMWORTHI R 1 1 INTERNAL: ARM/DAF/LFMB 1 0 NRR/DEST/ADS7E4 1 NRR/DEST/CEBSH7 1 1 NRR/DEST/MTB 9H 1 1 NRR/DEBT/RSB 8E 1 NRR/DOE*/TSB11F 1 1 A LRB12 1 OGC 15-B-18 . 1 0 REG FIL 01 1 RES/DE/EIB 1 EXTERNAL: LPDR 1 1 NRC PDR 1 1 NSIC 1 1 1

TOTAL NUMBER OF COPIES REQUIRED: LTTR 20 ENCL 17

Pl p

ll k

  • r) 1 I I >>I!

1'I>

Q

= Jj g'~i<)"<, I >

I' k

'a k.'$74'> N I Tlt

>'>I >1 I>1

'1 f(';,

Et

Washington Public Power Supply System 3000 George Washington Way P.O. Box 968 Richland, Washington 99352-0968 (509)372-5000 19, 1988 'ebruary G02-88-041 Docket No. 50-397 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Gentlemen:

Subject:

NUCLEAR PLANT NO. 2 OPERATING LICENSE NPF-21, REQUEST FOR A ONE TIME ONLY TEMPORARY AMENDMENT TO TECHNICAL SPECIFICATION 3.9.7 (CRANE TRAVEL-SPENT FUEL STORAGE POOL) UNDER EMERGENCY CIRCUMSTANCES (ADDITIONAL CLARIFICATION)

Reference:

Letter, G02-88-038 GC Sorensen (SS) to NRC same subject, dated February 18, 1988 A conference call was held the morning of February 19, 1988 between various members of the Supply System and the NRC Staff to discuss the reference submittal. As a result of the call, the Staff requested the following additional clarification:

1) An analysis was performed considering one of the purlins being dislodged from the roof structure and falling on the fuel pool cover (although this event is not considered credible since the purlins will be double tethered and would be fur ther constrained by the existing superstructure). The purlin, which is a W12 X 27 member 27 feet long was assumed to land on end on the 3/8" steel plate of the cover.

Analysis using standard ballistic methods showed that the 3/8" plate would not be penetrated by the purlin. Ensuing damage to the cover assembly has not been analyzed.

2) Although no credit is being taken for this action, an industrial safety net shall be put in place in the area of concern during the major phase of the repair work to the reactor building roof.

goo 8802290079 880219 PDR *DOCK 05000397 P

l 0 . ~

~ 'Page Two RE/VEST FOR A ONE TIME ONLY TEMPORARY AMEND. TO TS 3.9.7 (CRANE TRAVEL-SPENT FUEL STORAGE POOL) UNDER EMERGENCY CIRCUMSTANCES (ADDITIONAL CLARIFICATION)

3) When using both the reactor building crane and the Manitowac 4100 over the area of concern, all rigging below the hook will be 100K redundant.

The purlins will be tethered at both ends or equivalently tethered to provide 100K redundancy to any type of rigging in process, when they are not attached to the superstructure.

4) There is no safety related equipment essential for continued safe shutdown of the reactor that coul.d be damaged by a dropped object onto the refueling floor.

Should you have any questions, please contact Mr. P. L. Powell, Manager, WNP-2 Licensing.

Very truly your s, G. C. Sorensen, Manager Regulatory Programs PLP/bk cc: JB Martin - NRC RV NS Reynolds - BCP8R RB Samworth - NRC DL Williams - BPA/399 NRC Site Inspector 901A