ACCELERATED DI BUTION DEMONS TION SYSTEM REGULATORY INFORMATION DISTRIBUTXON SYSTEM (RXDS)

ACCESSION NBR: 9405160091 DOC. DATE: 94/05/06 NOTARIZED: YES DOCKET FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe 05000397 AUTH. NAME AUTHOR AFFILIATION PARRXSH,J.V. Washington Public Power Supply System RECIP.NAME RECIPIENT AFFILIATXON Document Control Branch (Document Control Desk)

SUBJECT:

Application for amend to license NPF-2l,revising TSs 3/4.3.7.5,3/4.4.2 S 3/4.5.1 for main steam relief valve position indication.

DISTRIBUTION CODE: AOOID TITLE: OR COPIES RECEIVED:LTR Submittal: General Distribution

/ ENCL J SIZE: L1 k NOTES:

RECIPIENT COPIES RECIPIENT COPI'ES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PDIV-3 LA 1 1 PDIV-3 PD 1 1 D CLIFFORD,J 2 2 D

INTERNAL: ACRS 6 6 NRR/DE/EELB 1 1 NRR/DORS/OTS B 1 1 NRR/DRCH/HICB 1 1 S

NRR/DRPW 1 1 NRR/DSSA/SPLB 1 1 NRR/DSSA/SRXB 1 1 NUDOCS-ABSTRACT 1 1 0 DCB 1 0 OGC/HDS1 1 0 REG FI 01 1 1 EXTERNAL: NRC PDR 1 1 NSXC 1 1 R

D D

D NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED: LTTR 22 ENCL 20

WASHINGTON PUBLIC POWER SUPPLY SYSTEM I'.O. Box 968 ~ 3000 George Washington Way ~ Richland, Washington 99352-0968 ~ (509) 372-5000 May 6, 1994 G02-94-109 Docket No. 50-397 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Gentlemen:

Subject:

WNP-2, OPERATING LICENSE NPF-21 REQUEST FOR AMENDMENT TO TECHNICAL SPECIFICATIONS 3/4.3.7.5, 3/4.4.2, AND 3/4.5.1 FOR MAIN STEAM RELIEF VALVE POSITION INDICATION SUPPLEMENTAL INFORMATION

Reference:

Letter GO2-93-281, dated December 6, 1993, JV Parrish (SS) to NRC, "Request for Amendment to Technical Specifications for Main Steam Relief" The purpose of this letter is to clarify the intent of the Supply System's request for amendment to Technical Specifications for main steam relief valve position indication submitted by the referenced letter. This request consists of proposed changes to Technical Specifications 3/4.3.7.5, "Accident Monitoring Instrumentation," 3/4.4.2, "Safety/Relief Valves," and 3/4.5.1, "Emergency Core Cooling Systems." These proposed changes require modification of Bases section 3/4.4.2. The proposed changes would clarify the operating conditions required for Safety Relief Valve (SRV) and Automatic Depressurization System SRV surveillance testing.

The current Technical Specifications and Bases are provided in Attachment 1 with the proposed changes annotated. Additional detail is provided in Attachment 2.

Granting the request involves no adverse safety impact and does not involve a significant hazards consideration.

9405gb0091 94050b PDR "',&DOCK 05000397 .

P, PDR

'I I

+',J rg*

I P ~

Page 2 REQUEST FOR AMENDMENTTO TECHNICALSPECIFICATIONS 3/4.3.7.5, 3/4.4.2, AND 3/4.5.1 FOR MAIN STEAM RELIEF VALVE POSITION INDICATION-SUPPLEMENTAL INFORMATION Approval of this amendment is required to support startup following the R-9 refueling outage, therefore staff approval is requested by June 15, 1994.

Should you have any questions or desire additional information regarding this matter, please call me or H. E. Kook at (509) 377-4278.

Sincerely, J, Parrish (Mail Drop 1023) sistant Managing Director, Operations DAS/bk Attachments CC: LJ Callan - NRC RIV KE Perkins, Jr. - NRC RIV, Walnut Creek Field Office NS Reynolds - Winston & Strawn JW Clifford - NRC DL Williams - BPA/399 NRC Sr. Resident Inspector - 927N

It y

STATE OF WASHINGTON )

Subject:

Request for Amendment to TS

) - SRV Testin R uirements COUNTY OF BENTON )

I, J. V. PARRISH, being duly sworn, subscribe to and say that I am the Assistant Managing Director, Operations for the WASHINGTON PUBLIC POWER SUPPLY SYSTEM, the applicant herein; that I have the full authority to execute this oath; that I have reviewed the foregoing; and that to the best of my knowledge, information, and belief the statements made in it are true.

DATE , 1993

.'rrish, Assistant Managing Director perations On this date personally appeared before me J. V. PARRISH, to me known to be the individual who executed the foregoing instrument, and acknowledged that he signed the same as his free act and deed for the uses and purposes herein mentioned.

GIVEN under my hand and seal this ~day of 1993.

otary Public in and for the STATE OF WASHINGTON y Residing at Kennewick Washin t n MyC i i i!yi

ly ~

Q%

~ II 1 II ~

g f

V,"

l REQtJESTFORAME T TO TECHNICALSPECIFIC IONS 3/4.3.7.5,3/4.4.2,

~

AND 3/4.5.1 FOR MAIN STEAM RELIEF VALVE POSITION INDICATION-SUPPLEMENTAL INFORMATION Attachment 1 Page 1 of 5 LIST OF AFFECTED PAGES

~Pa e Decri i n f hn 3/4 3-74 Accident Monitoring Revised Table 4.3.7.5-1 to include note which qualifies Instrumentation SRV position indicator applicability and surveillance requirements, including the exception provided by Technical Specification 4.0.'4 3/4 4-7a Safety/Relief Valves Revised note 4.4.2.b "~~" to identify that the 12-hour time limitation for performing the safety relief valve (SRV) position indicator surveillance testing starts when plant steam pressure and flow are adequate to perform the test.

3/4 5-5 Emergency Core Revised note 4.5.1.e.3.b "*"to identify that the 12-hour Cooling Systems- time limitation for performing the Automatic Operating Depressurization System SRV surveillance testing starts when plant steam pressure and flow are adequate to perform the test.

B 3/4 4-la Reactor Coolant Revised to include "adequate steam pressure and flow" System Bases to the description of "lower power" in describing testing Safety/Relief of SRVs.

Valves