Text
200 Exelon Way Exelon Generation Kennett Square, PA 19348 www. exeloncorp.com August 3, 2017 U.S. Nuclear Regulatory Commission A TIN: Document Control Desk Washington, DC 20555-0001 James A. FitzPatrick Nuclear Power Plant Renewed Facility Operating License No. DPR-59 NRG Docket No. 50-333 1 O CFR 50.55a
Subject:
Relief Requests Associated with Fifth Ten-Year lnservice Testing Interval Reference Letter from D. Gudger (Exelon Generation Company, LLC) to U.S. Nuclear Regulatory Commission, "Relief Request RR-001 for Extension of the 4th 10-Year lnservice Testing Interval," dated June 7, 2017 (ADAMS Accession No. ML171588295)
Attached for your review are relief requests associated with the fifth ten-year lnservice Testing (IST) Interval for James A. FitzPatrick Nuclear Power Plant (JAFNPP). The fifth interval of the JAFNPP IST program complies with the ASME OM Code, 2004 Edition through the OMb Code-2006 Addenda. In the reference letter, Exelon Generation Company, LLC, requested that the fourth interval be extended from September 30, 2017, to May 31, 2018. This request has been factored into the attached relief requests.
We request your approval by May 1, 2018.
There are no regulatory commitments contained within this letter.
If you have any questions concerning this letter, please contact Mr. David Neff at (610) 765-5631.
Sincerely, tJ~.J-r.L Jv--
David T. Gudger Manager - Licensing & Regulatory Affairs Exelon Generation Company, LLC
Attachment:
Relief Requests Associated with the Fifth Ten-Year Interval for FitzPatrick Nuclear Power Plant cc:
USNRC Region I, Regional Administrator USNRC Senior Resident Inspector, JAFNPP Project Manager USNRC, JAFNPP NY SERDA
Relief Requests Associated with the Fifth Ten-Year Interval for FitzPatrick Nuclear Power Plant Relief Request No.
Description PRR-01, Revision 0 Core Spray Pump Suction Pressure Gauge Range PRR-02, Revision 0 RHRSW Smooth Running Pumps PRR-03, Revision 0 RHR Pump Vibration Alert Range PRR-04, Revision 0 Code Case OMN-21 VRR-01, Revision 0 TIP CIV Stroke Time VRR-02, Revision 0 EFCV Sampling VRR-03, Revision 0 Code Case OMN-17 VRR-04, Revision 0 Leak Test at App J Frequency
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-01, Rev. 0, Core Spray Pump Suction Pressure Gauge Range Page 1 of 2 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS 14P-1A Core Spray Pump AFFECTED:
14P-1B Core Spray Pump CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTB-3500, Data Collection, paragraph ISTB-3510, General, (a)
Accuracy, states, in part: Instrument accuracy shall be within the limits of Table ISTB-3510-1 ISTB-3500, Data Collection, paragraph ISTB-3510, General, (b) Range, (1), states: The full-scale range of each analog instrument shall be not greater than three times the reference value.
ISTB-3500, Data Collection, Table ISTB 3510-1, Required Instrument Accuracy, requires pressure and differential pressure accuracy to be +/-
2% for Group A and Group B tests.
REASON FOR Pursuant to 10 CFR 50.55a(z)(2), an alternative is requested from the REQUEST:
ASME OM Code paragraph(s) ISTB 3500, Table ISTB 3510-1, that requires the suction and differential pressure accuracy to be within +/- 2%
of full scale range and ISTB 3510(b)(1) that requires the full-scale range of an analog instrument to be less than three times the reference value.
The basis of this request is that the Code requirements present an undue hardship without a compensating increase in the level of quality or safety.
PROPOSED JAF is proposing to use the existing installed plant suction pressure ALTERNATIVE gauges to determine the pump differential pressure for testing the Core AND BASIS:
Spray pumps for the Group B pump tests. The comprehensive tests are performed using Measuring and Test Equipment (M&TE).
The differential pressure for the Core Spray pumps is calculated using the installed suction and discharge pressure gauges. The suction pressure gauge is designed to provide adequate suction pressure indication during all expected operating conditions. The suction pressure gauge full-scale range of 72.28 pounds per square inch gauge (psig), [from 25 inches of mercury (12.28 psig) vacuum to 60 psig], is sufficient for a post-accident condition when the torus is at the maximum accident pressure. This, however, exceeds the range limit of 15 psig for the suction pressure under the test condition of approximately 5 psig.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-01, Rev. 0, Core Spray Pump Suction Pressure Gauge Range Page 2 of 2 PROPOSED The installed discharge pressure instrument loop is calibrated to within ALTERNATIVE
+/- 2% full-scale accuracy. However, the installed suction pressure AND BASIS instrument loop is calibrated to within +/- 2.4% full-scale accuracy. The (Continued) full-scale range of the pump discharge pressure instrumentation loop is 500 psig. Pump discharge pressure during testing is typically 280 psig.
Thus, the maximum variation due to inaccuracy in measured suction pressure is +/- 1.7 psi and in measured discharge pressure is +/- 10 psi.
Therefore, the differential pressure (typical [Pdisch - Psuct]) would be (280 -
5), which is 275 +/- 11.7 psi for an inaccuracy of 4.3%. If the full-scale range of the suction pressure gauge was within the Code allowable of 3 times the reference value, or 15 psig, the maximum variation due to inaccuracy in measured suction pressure would be +/- 0.3 psi and the resulting differential pressure measurement would be 275 +/- 10.3 psi for an inaccuracy of 3.7%.
The decrease in inaccuracy of 0.6%, by using the Code compliant gauge, is insignificant and does not warrant the additional manpower and exposure required to change the suction pressure gauge quarterly for test purposes.
In addition, the Code would allow a full-scale range for the discharge pressure measurement of 840 psig for the typical 280 psig discharge pressure. This would translate into a differential pressure measurement of 275 +/- 17.1 psig or an inaccuracy of 6.2%, if the installed instrumentation met the Code requirements of 0 - 15 psig for the suction pressure gauge and 0 - 840 psig for the discharge pressure gauge. The existing measurement is significantly better than the maximum Code allowable inaccuracy.
Based on the hardship resulting from implementing the OM Code requirements without a compensating increase in the level of quality and safety, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(2).
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027 PRECEDENT:
This proposed 10 CFR 50.55a alternative (for the instrument range) was previously authorized for use as PRR-02 at JAF during the fourth 10-year IST interval via the NRCs Safety Evaluation, dated November 27, 2007.
(ADAMS Accession No. ML072910422)
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-02, Rev. 0, RHRSW Smooth Running Pumps Page 1 of 3 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS 10P-1A, Residual Heat Removal Service Water (RHRSW) Pump AFFECTED:
10P-1B, RHRSW Pump 10P-1C, RHRSW Pump 10P-1D, RHRSW Pump The RHRSW pumps are vertical line shaft pumps that provide cooling water to the Residual Heat Removal (RHR) heat exchangers during normal operation, cold shutdown, refueling operation, in addition to a design basis event. These smooth running pumps are in the JAF inservice testing (IST) program and are ASME OM Code Group A pumps.
CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTB-3300, Reference Values, states that Reference values shall be obtained as follows: ISTB-3300(a), states: Initial reference values shall be determined from the results of testing meeting the requirements of ISTB-3100, Preservice Testing, or from the results of the first inservice test.
REASON FOR Pursuant to 10 CFR 50.55a(z)(1), an alternative is requested from the REQUEST:
ASME OM Code ISTB requirements referenced above, related to the vibration reference value (Vr), for the pumps that are identified as smooth running pumps. The basis of this request is that the alternative reference values provide an acceptable level of quality or safety.
The smooth running pumps in the JAF Nuclear Power Plant IST Program have at least one vibration reference value (Vr) that is currently less than 0.05 inches per second (ips). A small value for Vr produces a small acceptable range for pump operation. The OM Code Acceptable Range limit for pump vibrations from Table ISTB-5221-1, Vertical Line Shaft Centrifugal Pump Test Acceptance Criteria, for both the Group A test and Comprehensive test is 2.5 Vr. Based on a small acceptable range, a smooth running pump could be subject to unnecessary corrective action if it exceeds this limit.
ISTB-6200, Corrective Action, (a), Alert Range, states; If the measured test parameter values fall within the alert range of Table ISTB-5121-1, Table ISTB-5221-1, Table ISTB-5321-1 or Table ISTB-5321-2, as applicable, the frequency of testing specified in ISTB-3400 shall be doubled until the cause of the deviation is determined and the condition is corrected.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-02, Rev. 0, RHRSW Smooth Running Pumps Page 2 of 3 REASON FOR For very small reference values for vibrations, a significant portion of the REQUEST reading can be from flow variations, hydraulic noise, and instrument (Continued):
error, which can affect the repeatability of subsequent measurements.
Also, experience gathered by the JAF Nuclear Power Plant Predictive Maintenance (PdM) group has shown that changes in vibration levels in the range of 0.05 ips do not normally indicate significant degradation in pump performance.
In order to avoid unnecessary corrective actions, a minimum value for Vr of 0.05 ips is proposed. This minimum value would be applied to individual vibration locations, for the RHRSW pumps identified in this alternative request, with reference vibration values less than 0.05 ips.
PROPOSED In lieu of applying the reference values required by ISTB-3300, for ALTERNATIVE smooth running pumps with a measured reference value below 0.05 ips, AND BASIS:
JAF will apply a minimum value for Vr of 0.05 ips for the particular vibration measurement location. This minimum value would be applied to individual vibration locations for the RHRSW pumps, identified in this alternative request. The subsequent test results for that location will be compared to an Alert Range limit of 0.125 ips and a Required Action limit of 0.300 ips. These ranges, resulting from the proposed Vr of 0.05 ips and using the existing OM Code multipliers, shall be applied to vibration test results during both Group A and Comprehensive tests.
Therefore, the smallest OM Code Alert Range limit for any IST pump vibration location would be > 2.5 times Vr, or 0.125 ips, which is within the fair range of the General Machinery Vibration Severity Chart provided by IRD Mechanalysis, Inc. Likewise, the smallest OM Code Required Action limit for any IST Pump vibration location for which the pump would be inoperable would be > 6 times Vr, or 0.300 ips.
For comparison purposes, ASME Section XI, Table IWP-3100-2, Allowable Ranges of Test Quantities, specifies a vibration Acceptable Range limit of 1.0 mil for a displacement reference value 0.5 mils. In velocity units, a displacement reference value of 0.5 mils is equivalent to 0.047 ips for an 1800 rpm pump and 0.094 ips for a 3600 rpm pump. The minimum reference value proposed (0.05 ips) for smooth-running pumps is roughly equal to the ASME Code Section XI IWP reference value for an 1800 rpm pump and more conservative than the reference value for a 3600 rpm pump.
In addition to the requirements of OM Code Subsection ISTB for IST, the pumps in the JAF Nuclear Power Plant IST Program are also included in the JAF Nuclear Power Plant PdM Program. The JAF Nuclear Power Plant PdM Program currently employs predictive monitoring techniques such as: vibration monitoring and analysis beyond that required by Subsection ISTB, bearing temperature trending, oil sampling and analysis, and/or thermography and analysis, as applicable.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-02, Rev. 0, RHRSW Smooth Running Pumps Page 3 of 3 PROPOSED If the measured parameters are outside the normal operating range or are ALTERNATIVE determined by analysis to be trending toward an unacceptable degraded AND BASIS state, appropriate actions are taken that may include: initiate an Issue (Continued):
Report (IR), increase monitoring to establish a rate of change, review component specific information to identify the cause, and remove the affected pump from service to perform maintenance.
It should be noted that the pumps in the IST Program will remain in the JAF PdM program even if certain pumps have very low vibration readings and are considered to be smooth running pumps.
Using the provisions of this request as an alternative to the required reference value determination specified in ISTB-3300, the vibration acceptance criteria, based on the alternative reference value, provides an acceptable level of quality and safety since the alternative provides reasonable assurance of pump operational readiness and the ability to detect pump degradation. Therefore, pursuant to 10 CFR 50.55a(z)(1),
JAF requests use of the proposed alternative to the specific ISTB Code requirements identified in this 10CFR50.55a Request.
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027 PRECEDENCE:
- 1. This 10CFR 50.55a request was previously approved for the Interval 4 IST Program at JAF via relief request PRR-04 in NRC SER dated November 27, 2007 (ADAMS Accession No. ML072910422).
- 2. Beaver Valley Power Station, Unit Nos. 1 and 2 (BVPS-1 and 2) -
Evaluation of Inservice Testing (IST) Pump Relief Request No. 8 Revisions 1K and 2I, respectively, NRC SER dated December 27, 2004 (ADAMS Accession No. ML043430042).
REFERENCES:
- 1. General Machinery Vibration Severity Chart provided by IRD Mechanalysis, Inc.
- 2. ASME Section XI, Subsection IWP, Inservice Testing of Pumps in Nuclear Power Plants, (IWP-3200-IWP-3400),1986 Edition
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 1 of 20 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS 10P-3A, Residual Heat Removal (RHR) Pump AFFECTED:
10P-3B, RHR Pump 10P-3C, RHR Pump 10P-3D, RHR Pump The four RHR pumps are classified as ASME Class 2 and OM Code Group A pumps.
CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTB Table ISTB-5121-1, Centrifugal Pump Test Acceptance Criteria provides the vibration Alert Range low-end absolute limit of 0.325 inches per second (ips) for the Group A and Comprehensive tests.
REASON FOR Pursuant to 10 CFR 50.55a(z)(2), an alternative is requested from the REQUEST:
ASME OM Code, Subsection ISTB, Table ISTB-5121-1 vibration Alert Range low-end absolute limit of 0.325 ips requirement during the Group A or biennial comprehensive pump test. The basis of this request is that the Code requirements present an undue hardship without a compensating increase in the level of quality or safety.
The increased periodicity of testing, resulting from the 0.325 ips Code requirement is an additional burden to the Operations staff, plant scheduling, and adds unnecessary run time to all RHR pumps. This request is based on analysis of vibration and pump differential pressure data indicating that no pump degradation is taking place.
PROPOSED JAF is proposing to use an alternative vibration Alert Range low-end ALTERNATIVE absolute limit of 0.408 ips. This provides an alternative method that AND BASIS:
continues to meet the intended function of monitoring the pump for degradation over time while keeping the required action level unchanged.
Pump Testing Methodology The RHR pumps at JAF are tested using a full flow recirculation test line back to the suppression pool for each pump surveillance test (including quarterly group A tests and biennial comprehensive pump tests). These pumps have a minimum flow line (per division) which is used only to protect the pump from overheating when pumping against a closed discharge valve. The minimum flow line isolation valve for each division is initially open when the pump is started, and flow is recirculated through
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 2 of 20 PROPOSED the minimum flow line back to the suppression pool. Then, the full flow ALTERNATIVE test line isolation valve is throttled open to establish flow through the AND BASIS full flow recirculation test line. The minimum flow line is then (Continued):
automatically isolated and all flow is directed through the full flow test line for the IST test. Based on the full flow test line configuration, this test methodology results in flow-induced, broadband vibration readings greater than 0.325 ips, but less than the required action limits.
The RHR system is operated in the same manner and under the same conditions for each IST test, regardless of whether JAF is operating or shutdown. Consequently, the pumps will experience the same potential for flow-induced, broadband vibration whenever they are tested, whether JAF is operating or shutdown. As a result, this alternative is proposed for the inservice testing of RHR pumps when vibration measurements are required.
NRC Staff Document NUREG/CP-0152 NRC Staff document NUREG/CP-0152, entitled Proceedings of the Fourth NRC/ASME Symposium on Valve and Pump Testing, dated July 15-18, 1996, included a paper prepared by the NRC staff, entitled Nuclear Power Plant Safety Related Pump Issues. That paper presented four key components that should be addressed in an alternative request of this type to streamline the review process. These four key components are as follows:
I. The licensee should have sufficient vibration history from the inservice testing which verifies that the pump has operated at the vibration level for a significant amount of time, with any spikes in the data justified.
II. The licensee should have consulted with the pump manufacturer or vibration expert about the level of vibration the pump is experiencing to determine if the pump operation is acceptable.
III. The licensee should describe attempts to lower the vibration below the defined code absolute levels through modifications to the pump.
IV. The licensee should perform a spectral analysis of the pump driver system to identify all contributors to the vibration levels.
The following is a discussion of how these four key components are addressed for this alternative request.
I.
Vibration History
- a. Testing Methods and Code Requirements Elevated vibration levels on the RHR pumps has been a condition that has existed since original installation. Prior to 1998, testing was measured in displacement (mils). These
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 3 of 20 PROPOSED readings were taken in two directions, horizontal in-line with ALTERNATIVE pump flow and horizontal perpendicular to pump flow. In 1998, AND BASIS JAF entered the third 10-year interval and implemented (Continued):
ASME/ANSI OM-1989, OM-6, for pump testing. During this interval, IST vibration data was taken in displacement (mils).
Additional data was also taken in velocity (ips), with an additional data point in the axial direction. At that time, the velocity data points were used as information only. Upon the fourth 10 year interval at JAF, ASME OM Code 2001 Edition with 2003 Addenda was adopted. With this adoption, it was determined that vibration measurements in velocity would be a much better indicator of pump condition and would be beneficial in terms of early identification of degradation. Therefore, data exists for two vibration points on each RHR pump from January 1986 to August 1998 in mils. Data from May of 1999 to present is in the form of ips at three vibration data points. Various analyses of this data are included as Figures 1 through 10 within this alternative request.
- b. Review of Vibration History Data IST trends of RHR Pump vibration (Figures 1 - 4), which include data from 1999 through present, indicate some readings to be at or above current IST vibration Alert criteria. From Figures 9 and 10, it can be seen that, 10P-3B and 10P-3C have exceeded the current OM Code Alert criteria of 0.325 ips.
RHR pump differential pressure trends (Figures 5 - 8) illustrate the differential pressure data during the same time period as the vibration Figures 1 - 4. These graphs display a step change in flow around the 2009 time frame. This change is due to surveillance test changes in which test flow was lowered. The change was made after engineering analysis resulted in revised pump flow criterion. These trends do not indicate any signs of hydraulic degradation.
A review of the maintenance history for all four pumps and motors reveals very minimal maintenance has been performed beyond the normally scheduled preventive maintenance. The only maintenance deemed to have the potential to affect vibration values is that of mechanical seal replacement. RHR pumps 10P-3A and 10P-3C both had mechanical seals replaced in 2009. Post work testing of these replacements did not result in any change in vibration values.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 4 of 20 PROPOSED Average run times for each RHR pump per cycle is ALTERNATIVE approximately 200-300 hours. Run times of this nature, AND BASIS combined with the pumps and motors being built and maintained (Continued):
to the nuclear quality standards, are considered to have a low likelihood for significant wear related degradation.
- c. Review of Spikes in Vibration Data Trends of recent vibration history (4th Interval) do not contain any significant spikes above baseline levels. Instead, all values are fairly consistent and there have been no significant degrading trends associated with vibration data for the past 16 years.
While the overall vibration trends have been steady, when compared to the OM Code, recent vibration data points have exceeded the OM Code Alert limit of 0.325 ips. RHR pump 10P-3B exceeded this value once in 2010 and once in 2014.
Also, RHR pump 10P-3C exceeded this value once in 2012 and twice in 2016. Without the relief, for the 4th IST Interval at JAF, granted by NRC in the Safety Evaluation dated September 15, 2014, these pumps would be on increased frequency testing even though there has been no pump degradation.
II.
Consultation - Pump Manufacturer/Vibration Expert During the initial investigation for the cause of the failed vibration acceptance criteria, Mancini Consulting Services (an industry pump expert) and Flowserve (the pump vendor) were consulted for input.
Each RHR pump motor is vertically mounted to the pump casing, with the piping entering and exiting the pump casing horizontally.
The RHR pump motors weigh approximately 6500 pounds and operate at 1800 rpm. Other motor specifications include: 1000 Horsepower (Hp), 3 Phase, 60 hz, 4000 Volts. The pump casing, weighing 6100 pounds, is mounted on a reinforced floor pad.
The 20-inch suction piping enters the room level with the pump centerline. An additional 20-inch line tees into the suction piping approximately 5 feet from the pump. The 16-inch discharge piping leaves the pump on the same plane as the suction piping but then elbows 90 degrees vertically 6 feet from the pump. This is then followed by a discharge check valve and an isolation valve on the vertical run. See figures 11 and 12 for the isometric layout of the suction and discharge piping near the RHR pumps.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 5 of 20 PROPOSED Vibration monitoring points are located on the RHR motor/pump ALTERNATIVE assembly. Points V1, V2, and V3 (Vaxial) are the specified AND BASIS locations for IST data collection. V1 is taken in the vertical (Continued):
direction in line with pump flow. V2 is taken 90 degrees from V1 perpendicular to pump flow. V3 is taken 90 degrees from the V1 and V2 plane, on the underside of the motor.
Resonance testing was performed on all four RHR pump housings in the V1, V2, and V3 directions. Analysis has shown that the contributing cause of vibration in the V1 and V2 directions is from broadband peaks in the spectrum between 85.1 to 102.7 hz. These frequencies fall in the area of pump operation as these pumps are of a 3-vane design. In the case of the RHR pumps, vane pass frequency excitations are influencing vibration measurements.
III. Attempts to Lower Vibration Prior to completely understanding the cause of the vibration, it was thought that after the adjustment of testing flow in early 2009, vibrations would decrease. Through the recent analysis of the vibration spectrum, the structural resonance and the running speed peaks were confirmed. This analysis indicated that the running speed spectral peaks are consistent over years of testing. With the resonant frequency being considered as a significant contributor to exceeding the Alert vibration range, options to reduce resonance reside in stiffening the pump or an internal design change (i.e.
modifying to a 5-vane design).
JAF initially pursued a path to add additional stiffening to the pump and piping system. With the addition of supports, a new seismic analysis would be required for each RHR pump and the associated piping. Due to the complexity and resources needed for a new analysis, combined with the industry OE (reference Fermi 2 approved submittal ML101670372) which shows that stiffening operations also lend to the potential for vibrations to be transferred to the surrounding piping, efforts were ceased.
Major modifications, such as to add stiffening to the pump/motor system or changing the pump to a 5-vane design, when the pumps are not seen as degrading, are not deemed to result in an increase in the level of safety.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 6 of 20 PROPOSED IV. Spectral Analysis ALTERNATIVE AND BASIS ASME OM Code 2004 Edition/2006 Addenda paragraph ISTB-6400 (Continued):
states: If the reference value of a particular parameter being measured or determined can be significantly influenced by other related conditions, then these conditions shall be analyzed1 and documented in the record of tests. (See ISTB-9000).
The footnote (1) for analyzed states: Vibration measurements of pumps may be foundation, driver, and piping dependent. Therefore, if initial readings are high and have no obvious relationship to the pump, then vibration measurements should be taken at the driver, at the foundation, and on the piping and analyzed to ensure that the reference vibration measurements are representative of the pump and the measured vibration levels will not prevent the pump from fulfilling its function.
Spectral analysis was performed showing the total vibration broken down into individual frequencies over a span from 0-1500 hz. The analysis, which included a historical compilation of the data points that coincide with the IST surveillance testing, shows the broadband vibration is seen occurring at three times the pump running speed.
These vibrations may exceed the Code Alert criteria, which would trigger the corrective action process and the need to increase the testing frequency.
Spectral data indicates that the overall vibration levels are primarily made up of a spectrum from 85 to 103 hz due to the vane pass frequency induced by a 3-vane pump at 1800 rpm. As this vibration stems from the design of the pump, all four RHR pumps are susceptible. This vibration is accentuated on 10P-3B and 10P-3C due to the similar piping configurations. Spectral data do not indicate any degradation to the bearings, pump, or motor that would lead to imbalance or misalignment.
Basis for the OM Code Alternative Alert Values By this alternative request, JAF is proposing to increase the Alert Range low-end absolute limit for vibration from 0.325 ips to 0.408 ips for all four RHR pumps in the V1 and V2 directions. The vane pass induced broadband vibration occasionally causes the overall vibration value to exceed 0.325 ips, resulting in the pumps being placed on an increased testing frequency. A new Alert acceptance criterion of 0.408 ips coincides with the warning level that is already developed per the Predictive Maintenance (PdM) Program. The basis for the 0.408 ips warning level came from the Technical Associates of Charlotte recommendations for vertical pumps. The set points recommended were 0.350 ips and 0.525 ips. The PdM program uses those set points as high and low criteria but the program also has two additional levels. These two additional levels
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 7 of 20 PROPOSED split the difference between the suggested set points, resulting in ALTERNATIVE 0.408 ips and 0.466 ips.
AND BASIS (Continued):
The RHR Pump vendor (Byron Jackson, now owned by Flowserve) did not recommend a specific value regarding the increased vibration Alert limit, but stated that the pumps should not be adversely impacted provided that no upward trend existed in the vibration measurement data.
Expert analyses and maintenance reviews have shown that this vibration has not resulted in degradation to the pump or motor. Data trends show that overall vibrations have remained steady since 1998.
The new Alert criterion value allows an alternative measure that still meets the intended function of monitoring the pump for degradation, while leaving the action levels as mandated by the OM Code. The proposed criterion encompasses the previous values that exceeded the Alert level, which would eliminate the unnecessary actions associated with exceeding the OM Code Alert limit when the pump is not seen as degrading. Any corrective actions triggered by vibrations between 0.408 ips to 0.7 ips will result in the same OM Code actions as previously required when exceeding the Alert limit of 0.325 ips.
The vibration specialist at JAF routinely performs a spectral analysis on all data recorded during RHR pump inservice testing. This analysis is in addition to IST total vibration values. The analysis provides additional confidence on the ability to detect degradation at an early stage.
Each RHR pump motor is also monitored through the Preventive Maintenance (PM) and PdM programs. While these actions are intended to prevent degradation, any off-normal or unexpected conditions, will act as an indicator of the early stages of degradation. PM and PdM activities include: annual non-intrusive thermography, annual motor bearing sample, and 10-year internal visual inspection.
Conclusion Based on the hardship resulting from implementing the OM Code requirements without a compensating increase in the level of quality and safety, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(2). JAF considers the proposal to use an alternative vibration Alert Range low-end absolute limit of greater than or equal to 0.408 ips, while keeping the required action level unchanged, will provide an alternative method that continues to meet the intended function of monitoring the RHR pumps for degradation over time.
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 8 of 20 PRECEDENCE:
- 1. This 10CFR50.55a request was previously approved for the Interval 4 IST Program at JAF via Relief Request PRR-05 in the Safety Evaluation, dated September 15, 2014 (ML14241A329)
- 2. Cooper Nuclear Station - RE: Request for Relief (Relief Request RP-06, Revision 2) from the Requirements of ASME Code concerning Inservice Testing of Core Spray Pump CS-P-B, dated February 25, 2004 (ML040560318)
- 3. Evaluation of Relief Request PR-2 Associated with Second 10-Year Interval Inservice Testing Program for Pumps and Valves for Byron Station, Units 1 and 2, dated February 19, 2002 (ML020070381)
- 4. Fermi 2 - Evaluation of Relief Request Nos: PRR-004, PRR-005, PRR-007, and PRR-010 for the Third 10-Year Interval Inservice Program, dated July 6, 2010 (ML101670372)
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 9 of 20 Figure 1 - RHR 10P-3A 3rd and 4th interval vibration data in the V1, V2 and V3 directions
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 10 of 20 Figure 2 - RHR 10P-3B 3rd and 4th interval vibration data in the V1, V2 and V3 directions
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 11 of 20 Figure 3 - RHR 10P-3C 3rd and 4th interval vibration data in the V1, V2 and V3 directions
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 12 of 20 Figure 4 - RHR 10P-3D 3rd and 4th interval vibration data in the V1, V2 and V3 directions
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 13 of 20 Figure 5 - RHR 10P-3A 3rd and 4th interval differential pressure readings
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 14 of 20 Figure 6 - RHR 10P-3B 3rd and 4th interval differential pressure readings
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 15 of 20 Figure 7 - RHR 10P-3C 3rd and 4th interval differential pressure readings
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 16 of 20 Figure 8 - RHR 10P-3D 3rd and 4th interval differential pressure readings
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 17 of 20 Figure 9 - Recent history of RHR 10P-3B in the V1 direction compared to ASME OM Code Alert Criteria
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 18 of 20 Figure 10 - Recent history of RHR 10P-3C in the V1 direction compared to ASME OM Code Alert Criteria
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 19 of 20 Figure 11 - Isometric of Suction piping for 10P-3A and 10P-3C
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
PRR-03, Rev. 0, RHR Pump Vibration Alert Range Page 20 of 20 Figure 12 - Isometric of Discharge piping for 10P-3A and 10P-3C
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-04, Rev. 0, Code Case OMN-21 Page 1 of 4 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS AFFECTED:
Refer to Table PRR-04 CODE EDITION AND ADDENDA:
ASME OM Code-2004 Edition with Addenda through OMb-2006 REQUIREMENTS: ISTB-5121, "Group A Test Procedure," paragraph ISTB-5121(b) states, in part, that The resistance of the system shall be varied until the flow rate equals the reference point. Alternatively, the flow rate shall be varied until the differential pressure equals the reference point ISTB-5122, "Group B Test Procedure," paragraph ISTB-5122(c) states, System resistance may be varied as necessary to achieve the reference point.
ISTB-5123, "Comprehensive Test Procedure," paragraph ISTB-5123(b) states, in part, that the resistance of the system shall be varied until the flow rate equals the reference point. Alternatively, the flow rate shall be varied until the differential pressure equals the reference point ISTB-5221, "Group A Test Procedure," paragraph ISTB-5221(b) states, in part, that The resistance of the system shall be varied until the flow rate equals the reference point. Alternatively, the flow rate shall be varied until the differential pressure equals the reference point ISTB-5222, "Group B Test Procedure," paragraph ISTB-5222(c) states, System resistance may be varied as necessary to achieve the reference point.
ISTB-5223, "Comprehensive Test Procedure," paragraph ISTB-5123(b) states, in part, that The resistance of the system shall be varied until the flow rate equals the reference point....Alternatively, the flow rate shall be varied until the differential pressure equals the reference point REASON FOR REQUEST:
Pursuant to 10 CFR 50.55a(z)(1), an alternative is proposed to the pump testing reference value requirements of the ASME OM Code. The basis of the request is that the proposed alternative would provide an acceptable level of quality and safety. Specifically, this alternative is requested for all inservice testing of IST Program pumps as listed in attached Table PRR-04, Pumps Affected by Alternative Request PRR-04.
For pump testing, there is difficulty adjusting system throttle valves with sufficient precision to achieve exact flow reference values during subsequent IST tests. Subsection ISTB of the ASME OM Code does not
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-04, Rev. 0, Code Case OMN-21 Page 2 of 4 REASON FOR REQUEST (Continued):
allow for variance from a fixed reference value for pump testing. However, NUREG-1482, Guidelines for Inservice Testing at Nuclear Power Plants:
Inservice Testing of Pumps and Valves and Inservice Examination and Testing of Dynamic Restraints (Snubbers) at Nuclear Power Plants, Revision 2, Section 5.3, acknowledges that certain pump system designs do not allow for the licensee to set the flow at an exact value because of limitations in the instruments and controls for maintaining steady flow.
ASME OM Code Case OMN-21, Alternative Requirements for Adjusting Hydraulic Parameters to Specified Reference Points, provides guidance for adjusting reference flow or differential pressure (P) to within a specified tolerance during inservice testing.
The OM Code Case OMN-21 states, It is the opinion of the Committee that when it is impractical to operate a pump at a specified reference point and adjust the resistance of the system to a specified reference point for either flow rate, differential pressure or discharge pressure, the pump may be operated as close as practical to the specified reference point with the following requirements. The Owner shall adjust the system resistance to as close as practical to the specified reference point where the variance from the reference point does not exceed +2% or -1% of the reference point when the reference point is flow rate, or +1% or -2% of the reference point when the reference point is differential pressure or discharge pressure.
The NRC also discusses this ASME Code change in NUREG-1482, Revision 2, Section 5.3.
PROPOSED ALTERNATIVE AND BASIS:
JAF seeks to perform future inservice pump testing in a manner consistent with the requirements as stated in ASME OM Code Case OMN-21.
Specifically, testing of all pumps identified in Table PRR-04 will be performed such that the flow rate is adjusted as close as practical to the reference value and within proceduralized limits of +2% or -1% of the reference flow rate or alternatively the differential pressure or discharge pressure is adjusted as close as practical to the reference value and within proceduralized limits of +1% or -2% of the reference pressure or differential pressure.
JAF plant operators will continue to strive to achieve the exact test reference values (flow or differential pressure) during testing. Typical test guidance will be to adjust the reference parameter to the specific reference value with additional guidance that if the reference value cannot be achieved with reasonable effort the test will be considered valid if the steady state flow rate is within the proceduralized limits of +2% or -1% of the reference value or the pressure or differential pressure is within the proceduralized limits of +1% or -2% of the reference value.
The ASME Operation and Maintenance Standards Committee approved Code Case OMN-21 on April 20, 2012, with the NRC representative voting in the
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-04, Rev. 0, Code Case OMN-21 Page 3 of 4 PROPOSED ALTERNATIVE AND BASIS:
(Continued) affirmative. The applicability of Code Case OMN-21 is the ASME OM Code 1995 Edition through the 2011 Addenda. The language from Code Case OMN-21 has been included in the ASME OM Code, 2012 Edition.
Using the provisions of this request as an alternative to the specific requirements of ISTB-5121, ISTB-5122, ISTB-5123, ISTB-5221, ISTB-5222 and ISTB-5223, as described above, will provide adequate indication of pump performance and continue to provide an acceptable level of quality and safety.
Based on the determination that the use of controlled reference value ranges provides an acceptable level of quality and safety, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(1).
DURATION:
5th Interval beginning June 1, 2018, and ending September 30, 2027 PRECEDENTS:
- 1. Callaway Plant, Unit 1 - Request for Relief PR-06, Alternative to ASME OM Code Requirements for IST for the Fourth Program Interval - Safety Evaluation dated July 15, 2014 (ML14178A769)
- 2. Wolf Creek Generating Station - Request for Relief 4PR-01 for the Fourth 10-Year Inservice Testing Program Interval - Safety Evaluation dated May 15, 2015 (ML15134A002)
REFERENCES:
- 1. ASME Code Case OMN-21, Alternate Requirements for Adjusting Hydraulic Parameters to Specified Reference Points
- 2. NUREG-1482, Revision 2, Guidelines for Inservice Testing at Nuclear Power Plants: lnservice Testing of Pumps and Valves and Inservice Examination and Testing of Dynamic Restraints (Snubbers) at Nuclear Power Plants, Section 5.3, Allowable Variance from Reference Points and Fixed-Resistance Systems, dated October 2013 (ML13295A020)
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
PRR-04, Rev. 0, Code Case OMN-21 Page 4 of 4 Table PRR-04, Pumps Affected by Alternative Request PRR-04 Pump ID (Units 1 & 2)
Description Pump Type Code Class OM Code Category 11P-2A 11P-2B Standby Liquid Control Pumps Positive Displacement 2
Group B 14P-1A 14P-1B Core Spray Pumps Centrifugal 2
Group B 10P-3A 10P-3B 10P-3C 10P-3D Residual Heat Removal (RHR)\\Low Pressure Coolant Injection (LPCI)
Pumps Centrifugal 2
Group A 23P-1M High Pressure Coolant Injection (HPCI) Main Pump Centrifugal 2
Group B 23P-1B High Pressure Coolant Injection (HPCI) Booster Pump Centrifugal 2
Group B 10P-1A 10P-1B 10P-1C 10P-1D RHR Service Water Pumps Vertical Line Shaft Centrifugal 3
Group A 46P-2A 46P-2B Emergency Service Water Pumps Vertical Line Shaft Centrifugal 3
Group B
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
VRR-01, Rev. 0, TIP CIV Stroke Time Page 1 of 2 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS Traversing In-Core Probe (TIP) Containment Isolation Valves, AFFECTED:
07SOV-104A, B, and C CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTC-5151, Valve Stroke Testing ISTC-5151(a), states, Active valves shall have their stroke times measured when exercised in accordance with ISTC-3500.
ISTC-5151(c), states, Stroke time shall be measured to at least the nearest second.
REASON FOR Pursuant to 10 CFR 50.55a(z)(2), an alternative is requested to the REQUEST:
stroke time requirements of the ASME OM Code. The basis of this request is that the Code requirements present an undue hardship without a compensating increase in the level of quality or safety.
The Category A, containment isolation solenoid operated valves identified in this request have no safety function in the open direction as they open to allow the passage of the TIP assembly and drive cable for flux mapping operations. These valves have an active safety function in the closed direction in response to a primary containment isolation system signal to seal the TIP guide tubes. Therefore, an exercise test and subsequent stroke time test are only required in the closed direction.
However, the computer control system for the TIP system includes a provision for measuring valve cycle time (opened and closed) and not closure time alone. The sequence opens the subject valve (stroke < 2 seconds), maintains it energized for 10 seconds (including the opening stroke), and de-energizes the valve solenoid allowing the valve to stroke closed (< 2 seconds). The total elapsed time is specified to be 12 seconds.
The design of the TIP control system does not allow for measurement of the closure stroke times of valves 07SOV-104A, B, and C. Measuring the closure stroke times in accordance with the Code would be a hardship since it would require a costly computer control system modification.
Closure of valves 07SOV-104A, B, and C could also be accomplished by an alternative method but this method would require manual extraction and retraction of the TIP from the shield block. This method of testing
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(2)
VRR-01, Rev. 0, TIP CIV Stroke Time Page 2 of 2 REASON FOR would be contrary to the principles of keeping radiation exposure as low REQUEST:
as reasonably achievable because it would result in radiation exposure to (Continued) personnel performing the test.
The proposed alternative test ensures the operation of valves 07SOV-104A, B, and C in both directions and provides an acceptable level of quality and safety. This method meets the desired outcome of monitoring valve stroke time for degradation since the computer controls the 10-second delay and the additional approximate 2 seconds for valve closure should indicate the actual stroke time.
PROPOSED JAF proposes to measure overall cycle time (opened and closed) for the ALTERNATIVE TIP Containment Isolation Valves, 07SOV-104A, B, and C, in accordance AND BASIS:
with ISTC-5152. Specifically, JAF will time the opening (10-second delay time included) and closing cycle for valves 07SOV-104A, B, and C. The time from open initiation to receipt of the closed light for each valve will be monitored with a stop watch. JAF will apply ISTC-5152(a) which requires that each valve exhibit no more than +/- 25% change in stroke time when compared to the reference value except that the full stroke limiting time for each valve will be truncated at 12 seconds.
Based on the hardship resulting from implementing the OM Code requirements without a compensating increase in the level of quality and safety, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(2).
DURATION:
5th IST Interval beginning June 1, 2018, and ending September 30, 2027 PRECEDENT:
This proposed 10 CFR 50.55a alternative was previously authorized for use at JAF under VRR-02 for the Interval 4 IST Program via the NRC Safety Evaluation dated November 27, 2007 (ADAMS Accession No. ML072910422).
REFERENCE:
Letter from Entergy Nuclear Operations, Inc., Pete Dietrich, to US Nuclear Regulatory Commission, dated July 31, 2007, Response to request for Additional Information Regarding Proposed Relief Requests for James A.
FitzPatrick Nuclear Power Plant Fourth Interval In-Service Testing Program (ADAMS Accession No. ML072190608).
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 1 of 7 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS Excess Flow Check Valves (EFCVs) listed in the attached Table AFFECTED:
VRR-02, Excess Flow Check Valve Component List.
CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTC-3522, Category C Check Valves, paragraph (c) states: If exercising is not practicable during operation at power and cold shutdowns, it shall be performed during refueling outages.
REASON FOR Pursuant to 10 CFR 50.55a(z)(1), an alternative is proposed to the REQUEST:
requirements of ASME OM Code paragraph ISTC-3522(c). The basis of the request is that the proposed alternative would provide an acceptable level of quality and safety. The ASME OM Code requires check valves to be exercised quarterly during plant operation, or if valve exercising is not practicable during plant operation and cold shutdown, it shall be performed during refueling outages (RFOs).
These valves cannot be exercised closed during normal power operation since closing these valves would isolate instrumentation required for power operation. Isolation of any of these instruments from service may cause a spurious signal, which could result in a plant trip or an unnecessary challenge to safety systems. Testing on a cold shutdown frequency is impractical, considering the test condition for most of the EFCVs, requires that reactor pressure is available for testing. The appropriate time for performing EFCV testing is during RFOs, and for most of the EFCVs, in conjunction with the vessel in-service leakage (hydrostatic) testing. Recent improvements in RFO schedules minimized the time that is planned for refueling and testing activities during the outages. Considering the test conditions required for EFCV testing and the shortened outage durations, it is burdensome to test all these valves during RFOs.
Based on past experience, EFCV testing during in-service leakage testing can become the outage critical path and could possibly extend the outage if all EFCVs were to be tested during this time frame.
The testing described above requires isolation of the instruments associated with each EFCV and opening of a drain valve to actuate the EFCV. Process fluid will be contaminated to some degree, requiring special measures to collect flow from the drain valve and also contributes to an increase in personnel radiation exposure.
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 2 of 7 PROPOSED JAF proposes to exercise test, by full-stroke to the position required to ALTERNATIVE fulfill its function, a representative sample of EFCVs every refuel outage.
AND BASIS:
The representative sample is based on approximately 20 percent of the valves each cycle such that each valve is tested at least once every ten years (nominal).
Industry experience as documented in Boiling Water Reactor Owners Group (BWROG) report, NEDO-32977-A, (B21-00658-01), Excess Flow Check Valve Testing Relaxation, indicates that EFCVs have a very low failure rate. The instrument lines at JAF have a flow restricting orifice upstream of the EFCVs to limit reactor water leakage in the event of rupture. The JAF Final Safety Analysis Report (FSAR), paragraph 7.1.6, Supplemental NSSS Supplier Information, does not credit the EFCVs, but instead credits the installed orifice for limiting the release of reactor coolant following an instrument line break. Thus, a failure of an EFCV, though not expected as a result of this request, is bounded by the FSAR analysis. The JAF test experience is consistent with the findings in the NEDO document. The NEDO document indicates similarly that many reported test failures at other plants were related to test methodologies and not actual EFCV failures.
EFCV failures will be documented in the JAFs Corrective Action Program as an equipment and surveillance test failure. The failure will be evaluated and corrected to ensure EFCV performance remains consistent with the extended test interval, a minimum acceptance criteria of less than or equal to one failure per year on a three year rolling average will be required.
The basis of this request is that the proposed alternative, described above, would provide an acceptable level of quality and safety.
Therefore, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(1).
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 3 of 7 PRECEDENCE:
- 1.
This 10CFR50.55a request was previously approved as relief request VRR-03 for the JAF Interval 4 IST Program in NRC Safety Evaluation dated November 27, 2007 (ML072910422).
- 2.
Columbia Generating Station - Requests for Relief Nos. RG01, RP01, RP02, RP03, RP04, RP05, RP06, RV01, RV02, RV03 and RV04 for the Fourth 10-Year Inservice Testing Interval, NRC Safety Evaluation dated December 09, 2014, (ML14337A449).
REFERENCES
- 1.
BWROG Topical Report, NEDO-32977-A (B21-00658-01), Excess Flow Check Valve Testing Relaxation, June 2000.
- 2.
JAF FSAR, paragraph 7.1.6, Supplemental NSSS Supplier Information
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 4 of 7 Table VRR-02 Excess Flow Check Valve Component List VALVE NUMBER SYSTEM OM CATEGORY ASME CLASS 02-2EFV-PS-128A Reactor Water Recirculation A/C 1
02-2EFV-PS-128B Reactor Water Recirculation A/C 1
02-2EFV-PT-24A Reactor Water Recirculation A/C 1
02-2EFV-PT-24B Reactor Water Recirculation A/C 1
02-2EFV-PT-25A Reactor Water Recirculation A/C 1
02-2EFV-PT-25B Reactor Water Recirculation A/C 1
02-2EFV1-DPT-111A Reactor Water Recirculation A/C 1
02-2EFV1-DPT-111B Reactor Water Recirculation A/C 1
02-2EFV1-FT-110A Reactor Water Recirculation A/C 1
02-2EFV1-FT-110C Reactor Water Recirculation A/C 1
02-2EFV1-FT-110E Reactor Water Recirculation A/C 1
02-2EFV1-FT-110G Reactor Water Recirculation A/C 1
02-2EFV2-DPT-111A Reactor Water Recirculation A/C 1
02-2EFV2-DPT-111B Reactor Water Recirculation A/C 1
02-2EFV2-FT-110A Reactor Water Recirculation A/C 1
02-2EFV2-FT-110C Reactor Water Recirculation A/C 1
02-2EFV2-FT-110E Reactor Water Recirculation A/C 1
02-2EFV2-FT-110G Reactor Water Recirculation A/C 1
02-3EFV-11 Nuclear Boiler A/C 1
02-3EFV-13A Nuclear Boiler A/C 1
02-3EFV-13B Nuclear Boiler A/C 1
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 5 of 7 Table VRR-02 Excess Flow Check Valve Component List VALVE NUMBER SYSTEM OM CATEGORY ASME CLASS 02-3EFV-15A Nuclear Boiler A/C 1
02-3EFV-15B Nuclear Boiler A/C 1
02-3EFV-15N Nuclear Boiler A/C 1
02-3EFV-17A Nuclear Boiler A/C 1
02-3EFV-17B Nuclear Boiler A/C 1
02-3EFV-19A Nuclear Boiler A/C 1
02-3EFV-19B Nuclear Boiler A/C 1
02-3EFV-21A Nuclear Boiler A/C 1
02-3EFV-21B Nuclear Boiler A/C 1
02-3EFV-21C Nuclear Boiler A/C 1
02-3EFV-21D Nuclear Boiler A/C 1
02-3EFV-23A Nuclear Boiler A/C 1
02-3EFV-23B Nuclear Boiler A/C 1
02-3EFV-23C Nuclear Boiler A/C 1
02-3EFV-23D Nuclear Boiler A/C 1
02-3EFV-23 Nuclear Boiler A/C 1
02-3EFV-25 Nuclear Boiler A/C 1
02-3EFV-31A Nuclear Boiler A/C 1
02-3EFV-31B Nuclear Boiler A/C 1
02-3EFV-31C Nuclear Boiler A/C 1
02-3EFV-31D Nuclear Boiler A/C 1
02-3EFV-31E Nuclear Boiler A/C 1
02-3EFV-31F Nuclear Boiler A/C 1
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 6 of 7 Table VRR-02 Excess Flow Check Valve Component List VALVE NUMBER SYSTEM OM CATEGORY ASME CLASS 02-3EFV-31G Nuclear Boiler A/C 1
02-3EFV-31H Nuclear Boiler A/C 1
02-3EFV-31J Nuclear Boiler A/C 1
02-3EFV-31K Nuclear Boiler A/C 1
02-3EFV-31L Nuclear Boiler A/C 1
02-3EFV-31JM Nuclear Boiler A/C 1
02-3EFV-31N Nuclear Boiler A/C 1
02-3EFV-31P Nuclear Boiler A/C 1
02-3EFV-31R Nuclear Boiler A/C 1
02-3EFV-31S Nuclear Boiler A/C 1
02-3EFV-33 Nuclear Boiler A/C 1
13EFV-01A Nuclear Boiler A/C 1
13EFV-01B Nuclear Boiler A/C 1
13EFV-02A Nuclear Boiler A/C 1
13EFV-02B Nuclear Boiler A/C 1
14EFV-31A Core Spray A/C 1
14EFV-31B Core Spray A/C 1
23EFV-01A High Pressure Coolant Injection A/C 1
23EFV-01B High Pressure Coolant Injection A/C 1
23EFV-02A High Pressure Coolant Injection A/C 1
23EFV-02B High Pressure Coolant Injection A/C 1
29EFV-30A Main Steam A/C 1
29EFV-30B Main Steam A/C 1
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-02, Rev. 0, EFCV Sampling Page 7 of 7 Table VRR-02 Excess Flow Check Valve Component List VALVE NUMBER SYSTEM OM CATEGORY ASME CLASS 29EFV-30C Main Steam A/C 1
29EFV-30D Main Steam A/C 1
29EFV-34A Main Steam A/C 1
29EFV-34B Main Steam A/C 1
29EFV-34C Main Steam A/C 1
29EFV-34D Main Steam A/C 1
29EFV-53A Main Steam A/C 1
29EFV-53B Main Steam A/C 1
29EFV-53C Main Steam A/C 1
29EFV-53D Main Steam A/C 1
29EFV-54A Main Steam A/C 1
29EFV-54B Main Steam A/C 1
29EFV-54C Main Steam A/C 1
29EFV-54D Main Steam A/C 1
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 1 of 6 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS Main Steam Safety/Relief Valves (SRVs), 02RV-071A through AFFECTED:
02RV-071H and 02RV-071J through 02RV-071L CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ASME Code Mandatory Appendix I, paragraph I-1320(a), Test Frequencies, Class 1 Pressure Relief Valves, states, in part, that Class 1 pressure relief valves shall be tested at least once every 5 years REASON FOR Pursuant to 10 CFR 50.55a(z)(1), an alternative is requested to the REQUEST:
frequency requirement for testing Class 1 pressure relief valves every five years. JAF proposes to test Class 1 pressure relief valves every six years in accordance with ASME Code Case OMN-17, Alternative Rules for Testing ASME Class 1 Pressure Relief/Safety Valves, which was published via the American Society of Mechanical Engineers (ASME)
Operation and Maintenance of Nuclear Power Plants (OM) Code 2012 Edition. JAF considers that testing the Main Steam SRVs in accordance with ASME OM Code Case OMN-17 provides an acceptable level of quality and safety.
PROPOSED ASME OM Code Mandatory Appendix I, Inservice Testing of Pressure ALTERNATIVE Relief Devices in Light-Water Reactor Nuclear Power Plants, paragraph AND BASIS:
I-1320, Test Frequencies, Class 1 Pressure Relief Valves, (a) 5-Year Test Interval, requires that Class 1 pressure relief valves be tested at least once every five years. As an alternative to the Code required 5-year test interval per Mandatory Appendix I, paragraph I-1320(a), JAF proposes that Class 1 pressure relief valves, 02RV-071A, B, C, D, E, F, G, H, J, K, and L, be tested at least once every three (3) refueling cycles (approximately six years/72 months) with a minimum of 20% of the valves tested within any 24-month interval. This 20% would consist of valves (complete assemblies) that have not been tested during the current 72-month interval, if they exist. The test interval for any individual valve would not exceed 72 months except that a 6-month grace period is allowed to coincide with refueling outages to accommodate extended shutdown periods. JAF proposes to continue testing all eleven (11) installed pilot valves every refueling outage.
The Main Steam Pressure Relief system provides Reactor Coolant System (RCS) overpressure protection and automatic depressurization of the nuclear system by opening the SRVs. JAF updated Final Safety Analysis Report Section 4.4.4, Safety Design Bases, describes the main
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 2 of 6 PROPOSED protection functions of the SRVs as follows:
ALTERNATIVE AND BASIS
- 1. The pressure relief system prevents over-pressurization of the RCS in (Continued):
order to prevent failure of the reactor coolant pressure boundary due to pressure.
- 2. The pressure relief system provides automatic depressurization for small breaks in the RCS so that the low pressure coolant injection and the core spray systems can operate to protect the fuel barrier.
- 3. The pressure relief system provides for manual depressurization at a remote auxiliary panel located outside the control room in the highly unlikely event the control room was to become uninhabitable.
Seven of the eleven SRVs are a designated part of the Automatic Depressurization System (ADS) Emergency Core Cooling System (ECCS) and must open to provide automatic reactor depressurization as a result of a small break in the nuclear system for which the high pressure coolant injection system cannot maintain reactor water level (ADS function).
The relief valve testing and maintenance cycle at JAF consists of an as-found inspection, seat leakage and set pressure testing. After as-found set pressure testing, the valves shall be disassembled and inspected to verify that parts are free of defects resulting from time-related degradation or service induced wear. As-left set pressure testing shall be performed following maintenance and prior to returning the valve to service.
Prior to the return of a complement of SRVs for installation in the plant, the valves are disassembled and inspected to verify that internal surfaces and parts are free from defects or service induced wear prior to the start of the next test interval. During this process, anomalies or damage are identified and resolved. Damaged or worn parts, springs, gaskets and seals are replaced as necessary. Following reassembly, the valve's set pressure is recertified with an acceptance criterion of +/-1%. This existing process is in accordance with ASME OM Code Case OMN-17, paragraphs (d) and (e). This Code Case has not been approved for use in US NRC Regulatory Guide 1.192, "Operation and Maintenance Code Case Acceptability, ASME OM Code, dated June 2003.
The JAF SRV pilot valves test history, as described in VRR-03, Safety Relief Valve Pilot Valve Test Data, shows that the pilot valves are susceptible to disc-to-seat corrosion. This is a recurring industry issue that has been the subject of both NRC and Boiling Water Reactor Owners Group (BWROG) assessments. As described in Licensee Event Report (LER) 2015-002-00, dated July 30, 2015, and based on the known industry wide issues with the two-stage Target Rock SRVs, JAF has implemented the following industry recommendations:
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 3 of 6 PROPOSED ALTERNATIVE AND BASIS (Continued):
- 2. Installed the electric lift system recommended by the BWROG;
- 3. Installed enhanced insulation on the SRVs;
- 4. Redirected ventilation air flow away from the SRVs; and
- 5. Began a phased replacement of 2-stage SRVs with 3-stage.
As a result, JAF will continue to test and inspect 100% of the installed SRV pilot valves each RFO until such time that successful test performance is achieved. The inspection and testing of the SRV valve assemblies, performed to date, have not identified any relevant issues.
However, given the current 24-month operating cycle, JAF would be required to remove and test 50 percent of the SRVs every refueling outage (i.e. five or six of 11), such that all valves are removed and tested every two refueling outages. This would ensure compliance with the ASME OM Code requirements for testing Class 1 pressure relief valves within a five-year interval. Approval of extending the test interval for the valves to six years with a grace period of six months, consistent with Code Case OMN-17, would reduce the minimum number of SRVs tested at JAF over three refueling outages.
Pursuant to 10 CFR 50.55a(z)(1), an alternative is proposed to the frequency requirement for testing Class 1 pressure relief valves every five years. JAF proposes to test Class 1 pressure relief valves every six years, with a grace period of six months, in accordance with ASME Code Case OMN-17, Alternative Rules for Testing ASME Class1 Pressure Relief/Safety Valves. JAF proposes to continue testing all 11 installed pilot valves every RFO outage until such time that successful test performance is achieved. JAF considers that testing the Main Steam SRVs in accordance with ASME OM Code Case OMN-17 and the installed SRV pilot valves each refueling outage will provide an acceptable level of quality and safety.
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027 PRECEDENTS:
- 1. Approved for JAF Interval 4 IST Program, as relief request VRR-06, in NRC Safety Evaluation dated October 1, 2009 (ML092730032).
- 2. Approved for Entergy Operation, Incorporated, in NRC SER dated March 23, 2015, River Bend Station, Unit 1 - Relief Request No. VRR-RBS-2014-1 Regarding the Third 10-year Inservice Test Interval (TAC No, MF4125), (ML15071A141).
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 4 of 6
REFERENCES:
- 1. JAF LER 2015-002-00, Safety Relief Valve Upward Setpoint Drift, dated July 30, 2015, (ML15212A272).
- 2. ASME OM Code Case OMN-17, Alternative Rules for Testing ASME Class 1 Pressure Relief/Safety Valves
- 3. JAF FSAR Update, Revision 5, Section 4.4, Pressure Relief System, subsection 4.4.4, Safety Design Basis
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 5 of 6 VRR-03 Attachment 1, Safety Relief Valve Pilot Valve Test Data S/N Cycle 18 Installed Location Model As Found Set Pressure Deviation
(%)
Set Pressure 1047 02RV-71C 2-stage 1184 3.29%
1145 1080 02RV-71E 2-stage 1187 3.54%
1145 1052 02RV-71F 2-stage No Lift 1145 1088 02RV-71A 2-stage 1148 0.26%
1145 1237 02RV-71B 2-stage 1192 3.94%
1145 1111 02RV-71D 2-stage 1157 1.04%
1145 1053 02RV-71G 2-stage No Lift 1145 1194 02RV-71H 2-stage 1169 2.05%
1145 1192 02RV-71K 2-stage 1156 0.95%
1145 1056 02RV-71J 2-stage 1168 1.97%
1145 1053 02RV-71L 2-stage 1177 2.72%
1145 1193 2-stage 1245 8.03%
1145 1238 1227 6.68%
1145 S/N Cycle 19 Installed Location Model As Found Set Pressure Deviation
(%)
Set Pressure 1045 02RV-71C 3-stage 1206 5.33%
1145 1191 02RV-71E 3-stage No Lift 1145 1236 02RV-71F 3-stage No Lift 1145 1087 02RV-71A 2-stage 1163 N/A 1145 1218 02RV-71B 2-stage 1208 5.50%
1145 1143 02RV-71D 2-stage 1145 1217 02RV-71G 2-stage 1192 4.10%
1145 1235 02RV-71H 2-stage No Lift 1145 1051 02RV-71K 2-stage No Lift 1145 1195 02RV-71J 2-stage 1246 8.82%
1145 1052 02RV-71L 2-stage 1163 1.57%
1145 1238 1189 3.84%
1145 1013 2-stage 1159 1.22%
1145 1110 2-stage 1164 1.66%
1145
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-03, Rev. 0, Code Case OMN-17 Page 6 of 6 VRR-03 Attachment 1, Safety Relief Valve Pilot Valve Test Data (Continued)
S/N Cycle 20 Installed Location Model As Found Set Pressure Deviation
(%)
Set Pressure TR2 02RV-71C 3-stage 1132
-1.14%
1145 TR3 02RV-71E 3-stage 1155 0.87%
1145 TR4 02RV-71F 3-stage 1151 0.52%
1145 1088 02RV-71A 2-stage 1195 4.37%
1145 1193 02RV-71B 2-stage 1150 0.44%
1145 1194 02RV-71D 2-stage 1159 1.22%
1145 1047 02RV-71G 2-stage 1150 0.44%
1145 1192 02RV-71H 2-stage 1183 3.32%
1145 1111 02RV-71K 2-stage 1162 1.48%
1145 1080 02RV-71J 2-stage 1177 2.79%
1145 1056 02RV-71L 2-stage 1141
-0.35%
1145 S/N Cycle 21 Installed Location Model As Found Set Pressure Deviation
(%)
Set Pressure 11 02RV-71F 3-stage 1133
-1.05%
1145 58 02RV-71E 3-stage 1118
-2.36%
1145 61 02RV-71C 3-stage 1122
-2.01%
1145 1013 02RV-71A 2-stage 1140
-0.44%
1145 1045 02RV-71B 2-stage 1250 9.17%
1145 1052 02RV-71D 2-stage 1191 4.02%
1145 1110 02RV-71G 2-stage 1231 7.51%
1145 1195 02RV-71H 2-stage 1235 7.86%
1145 1217 02RV-71K 2-stage 1243 8.56%
1145 1218 02RV-71J 2-stage 1277 11.53%
1145 1235 02RV-71L 2-stage 1203 5.07%
1145
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 1 of 9 PLANT/UNIT:
James A. FitzPatrick (JAF) Nuclear Power Plant INTERVAL:
5th Interval beginning June 1, 2018, and ending September 30, 2027 COMPONENTS Pressure Isolation Valves (PIVs) listed in the attached Table AFFECTED:
VRR-04-01, Pressure Isolation Valve Component List.
CODE EDITION ASME OM Code-2004 Edition with Addenda through OMb-2006 AND ADDENDA:
REQUIREMENTS:
ISTC-3630, Leakage Rate for Other Than Containment Isolation Valves, paragraph ISTC-3630(a), Frequency, states: "Tests shall be conducted at least once every 2 years.
REASON FOR Pursuant to 10 CFR 50.55a(z)(1), an alternative is proposed to the REQUEST:
frequency requirements of ASME OM Code ISTC-3630(a) for the subject valves. ISTC-3630(a) requires that leakage rate testing of Category A valves with a leakage requirement that is not based on 10CFR50 Appendix J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors, be conducted at least every two years. At JAF, PIVs are Category A or Category A/C valves within the scope of ISTC-3630. This alternative, to allow for scheduling of leak tests, for the valves identified in Table VRR-04-01, to a performance-based frequency that is the same as 10 CFR 50, Appendix J, Option B, Performance-Based Requirements, testing, would provide an acceptable level of quality and safety.
PROPOSED JAF proposes an alternative test frequency in lieu of the requirements ALTERNATIVE found in ISTC-3630(a) for the ten applicable PIVs listed in the attached AND BASIS:
Table VRR-04-01. Specifically, JAF proposes to perform the valve leakage rate test at a frequency in accordance with the 10 CFR 50, Appendix J, Option B schedule. The identified valves were initially tested at the ISTC-3630(a) required interval schedule, which was every RFO or two years, during the 3rd ten-year IST interval at JAF, and have subsequently been tested at the 10 CFR 50, Appendix J, Option B frequency, if applicable, during the 4th ten-year IST interval. Valves that demonstrated good performance for two consecutive cycles may have had their test interval extended to a maximum of 75 months. Any leakage rate test failure required the component to return to the initial interval of every RFO or two years until good performance could again be established.
10 CFR 50, Appendix J, was amended to improve the focus of the body of regulations by eliminating prescriptive requirements that are marginal to safety and to provide licensees greater flexibility for cost-effective implementation methods for meeting regulatory safety objectives.
Consistent with this approach, 10CFR50, Appendix J, Option B is less prescriptive, utilizes risk-based insights and allows licensees to adopt
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 2 of 9 PROPOSED cost effective methods, including setting test intervals, for implementing ALTERNATIVE safety objectives underlying the requirements of Appendix J.
AND BASIS (Continued):
Nuclear Energy Institute (NEI) 94-01, Revision 3A, Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J, describes the risk-informed basis for extended test intervals under Option B. That justification documents valves which have demonstrated good leakage rate performance over two consecutive cycles are subject to future failures predominantly governed by the random failure rate of the component. NEI 94-01 also presents the results of a comprehensive risk analysis, including the statement that "the risk impact associated with increasing test intervals is negligible (less than 0.1 percent of total risk)".
NUREG 0933, Resolution of Generic Safety Issues, Issue 105, Interfacing Systems LOCA at LWRs, discussed the need for PIV leak rate testing based primarily on three pre-1980 historical failures of applicable valves industry-wide. These failures all involved human errors in either operations or maintenance. None of these failures involved inservice equipment degradation. The performance of PIV leak rate testing provides assurance of acceptable seat leakage with the valve in a closed condition. Typical PIV leak rate testing does not identify functional problems which may inhibit the valves ability to re-position from open to close.
For check valves, such functional testing is accomplished per ASME OM Code ISTC-3520, Exercising Requirements, and ISTC-3522, Category C Check Valves. Power-operated valves are routinely full stroke tested per ASME OM Code to ensure their functional capabilities. The functional tests for PIVs are performed only at an RFO frequency. Such testing is not performed online in order to prevent any possibility of an inadvertent Interfacing System Loss of Coolant Accident (ISLOCA) condition. The functional testing of the PIVs is adequate to identify any abnormal condition that might affect closure capability. Performance of the separate PIV leak rate testing does not contribute any additional assurance of functional capability; it verifies the seat tightness of the closed valves. JAF proposes to perform PIV testing at intervals specified in NEI 94-01. The specific interval for each valve would be a function of its performance and would be established in a manner consistent with the Containment Isolation valve (CIV) process under 10 CFR 50, Appendix J, Option B. Program guidance will be established such that if any of the valves fail either the CIV test or PIV test, the test interval for both tests will be reduced to once every 30 months until they can be re-classified as good performers per the performance evaluation requirements of Appendix J, Option B. The test intervals for the valves identified in this request will be determined in the same manner as is done for CIV testing under Option B. That is, the test interval may be extended upon completion of two consecutive periodic PIV tests with results within the
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 3 of 9 PROPOSED prescribed acceptance criteria. Any PIV test failure will require a return ALTERNATIVE to the initial interval until good performance can again be established.
AND BASIS (Continued):
The intent of this request is to allow for a performance-based approach to the scheduling of PIV leakage testing. It has been shown that ISLOCA represents a small risk impact to BWRs such as JAF. NUREG 0933 Issue 105, references the conclusion from NUREG/CR-5928, "Final Report of the NRC-sponsored ISLOCA Research Program," that concludes, for the units studied, ISLOCA poses little risk.
The PIVs have an excellent performance history in terms of seat leakage testing (See VRR-04 Attachment 1, Pressure Isolation Valve Component Leakage History). It should be noted that component tests identified in VRR-04 Attachment 1 as LJ-C are performed using air as the test media. Alternatively, component tests identified in VRR-04 Attachment 1 as LKO are performed using water as the test media.
The risks associated with extending the leakage test interval to a maximum of 75 months are extremely low. The basis for this alternative request is the historically good performance of the PIVs. This alternative will also provide significant reductions in radiation dose.
Based on the determination that the scheduling of leak tests, for the valves identified in this request, to a performance based frequency that is the same as 10 CFR 50, Appendix J, Option B testing, would provide an acceptable level of quality and safety, this proposed alternative is requested pursuant to 10 CFR 50.55a(z)(1).
DURATION:
5th IST Interval, beginning June 1, 2018, and ending September 30, 2027 PRECEDENT:
This proposed 10 CFR 50.55a alternative was previously authorized for use at JAF under VRR-07 for the Interval 4 IST Program in NRC Safety Evaluation dated March 16, 2012 (ML12072A113).
REFERENCES:
- 1. NUREG 0933, Resolution of Generic Safety Issues, Issue 105, Interfacing Systems LOCA at LWRs
- 2. NUREG/CR-5928, ISLOCA Research Program, (ML072430731)
- 3. 10 CFR 50, Appendix J, Primary Reactor Containment Leakage Testing for Water-Cooled Power Reactors
- 4. NEI 94-01, Rev 3-A, Industry Guideline for Implementing Performance-Based Option of 10 CFR Part 50, Appendix J
- 5. James A. FitzPatrick Nuclear Power Plant - Issuance of Amendment Re: Revision of Technical Specification 5.5.6 for Extension of Type A and Type C Leak Rate Test Frequencies (CAC NO. MF8305, dated January 24, 2017, (ML17009A372)
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 4 of 9 Table VRR-04-01 Pressure Isolation Valve Component List VALVE NUMBER DESCRIPTION APPENDIX J OPTION B AIR TESTED OM CATEGORY 10AOV-68A RHR A LPCI TESTABLE CHECK VALVE No A/C 10AOV-68B RHR B LPCI TESTABLE CHECK VALVE No A/C 10MOV-25A RHR A LPCI INBD INJ VALVE Yes A
10MOV-25B RHR B LPCI INBD INJ VALVE Yes A
14AOV-13A CSP A REACTOR ISOL TESTABLE CHECK VALVE No A/C 14AOV-13B CSP B REACTOR ISOL TESTABLE CHECK VALVE No A/C 14MOV-12A CORE SPRAY LOOP A INBD ISOL VALVE Yes A
14MOV-12B CORE SPRAY LOOP B INBD ISOL VALVE Yes A
10MOV-17 RHR SHUTDOWN COOLING OUTBD ISOL VALVE Yes A
10MOV-18 RHR SHUTDOWN COOLING INBD ISOL VALVE Yes A
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 5 of 9 VRR-04 Attachment 1 - Pressure Isolation Valve Component Leakage History
- 1 - Documentation lost and test results not recorded 10AOV-68A Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/10/2002 LKO Sat 0.5 10 GPM 10/9/2004 LKO Sat 0
10 GPM 10/29/2006 LKO Sat 0
10 GPM 9/29/2008 LKO Sat 0
10 GPM 9/19/2010 LKO Sat 0
10 GPM 9/25/2012 LKO Sat 0
10 GPM 8/30/2014 LKO Sat 0
10 GPM 1/20/2017 LKO Sat 0.1 10 GPM 10AOV-68B Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/17/2002 LKO Sat 0
10 GPM 9/29/2004 LKO Sat 8.5 10 GPM 10/29/2006 LKO Sat 0
10 GPM 9/21/2008 LKO Sat 0
10 GPM 9/29/2010 LKO Sat
- 1 10 GPM 9/21/2012 LKO Sat 0.11 10 GPM 9/12/2014 LKO Sat 0
10 GPM 1/20/2017 LKO Sat 0
10 GPM
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 6 of 9 VRR-04 Attachment 1 - Pressure Isolation Valve Component Leakage History (Continued) 10MOV-25A Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/10/2004 LJ-C Sat 1.184 16 SLM 9/30/2008 LJ-C Sat 5.96 5.893 SLM 9/25/2012 LJ-C Sat 0.35 5.893 SLM 8/30/2014 LJ-C Sat 0.45 5.893 SLM 9/3/2002 LKO Sat 0
5 GPM 8/30/2006 LKO Sat 0
5 GPM 9/10/2010 LKO Sat 0.24 5
GPM 6/21/2012 LKO Sat 0
5 GPM 8/10/2016 LKO Sat 0
5 GPM 10MOV-25B Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/5/2004 LJ-C Sat 3.85 5.893 SLM 10/26/2006 LJ-C Sat 8.85 5.893 SLM 9/16/2008 LJ-C Sat 1.53 16 SLM 9/23/2008 LJ-C Sat 4.88 5.893 SLM 9/23/2012 LJ-C Sat 0.62 5.893 SLM 9/29/2012 LJ-C Sat 10.4 5.893 SLM 1/21/2017 LJ-C Sat 2.15 5.893 SLM 9/3/2002 LKO Sat 0
10 GPM 9/3/2006 LKO Sat 0
10 GPM 8/29/2010 LKO Sat 0
10 GPM 11/20/2016 LKO Sat 0
10 GPM
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 7 of 9 VRR-04 Attachment 1 - Pressure Isolation Valve Component Leakage History (Continued) 14AOV-13A Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/8/2002 LKO Sat 0
10 GPM 10/9/2004 LKO Sat 0
10 GPM 10/14/2006 LKO Sat 0
10 GPM 9/22/2008 LKO Sat 0
10 GPM 9/20/2010 LKO Sat 0
10 GPM 10/5/2012 LKO Sat 0
10 GPM 8/26/2014 LKO Sat 0
10 GPM 1/15/2017 LKO Sat 0
10 GPM 14AOV-13B Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/17/2002 LKO Sat 0
10 GPM 10/1/2004 LKO Sat 0.75 10 GPM 10/29/2006 LKO Sat 0.1044 10 GPM 9/18/2008 LKO Sat 0.11 10 GPM 9/29/2010 LKO Sat 0
10 GPM 9/20/2012 LKO Sat 0
10 GPM 9/15/2014 LKO Sat 0
10 GPM 1/23/2017 LKO Sat 0
10 GPM
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 8 of 9 VRR-04 Attachment 1 - Pressure Isolation Valve Component Leakage History (Continued) 14MOV-12A Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/9/2004 LJ-C Sat 0.019 16 SLM 9/25/2008 LJ-C Sat 0.113 1.473 SLM 9/13/2010 LJ-C Sat 0.351 1.473 SLM 9/3/2014 LJ-C Sat 0.052 1.473 SLM 1/16/2017 LJ-C Sat 0.38 1.473 SLM 10/8/2002 LKO Sat 0
5 GPM 10/14/2006 LKO Sat 0
5 GPM 9/3/2014 LKO Sat 0
5 GPM 14MOV-12B Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/3/2004 LJ-C Sat 0.007 1.473 SLM 9/15/2008 LJ-C Sat 0.722 16 SLM 9/29/2010 LJ-C Sat 0.38 1.473 SLM 9/19/2012 LJ-C Sat 0.034 1.473 SLM 1/30/2017 LJ-C Sat 0.51 1.473 SLM 10/17/2002 LKO Sat 0
5 GPM 10/28/2006 LKO Sat 0
5 GPM
JAMES A. FITZPATRICK NUCLEAR POWER PLANT IST PROGRAM - RELIEF REQUEST PROPOSED ALTERNATIVE IN ACCORDANCE WITH 10 CFR 50.55a(z)(1)
VRR-04, Rev. 0, Leak Test At App. J Frequency Page 9 of 9 VRR-04 Attachment 1 - Pressure Isolation Valve Component Leakage History (Continued)
Notes:
- 1. LKO is a leak test for other than a containment isolation valve. It is a water leakage test.
- 2. LJ-C is a Leak test per 10 CFR 50 Appendix J.
10MOV-17 Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 10/4/2004 LJ-C Sat 0.002 16 SLM 9/19/2008 LJ-C Sat 1.04 16 SLM 9/20/2010 LJ-C Sat 0.256 16 SLM 9/21/2012 LJ-C Sat 0.14 16 SLM 9/30/2012 LJ-C Sat 0.006 16 SLM 8/31/2014 LJ-C Sat 0.2 16 SLM 9/12/2014 LJ-C Sat 0.497 16 SLM 10MOV-18 Leakage History Test Date Test Type Test Result Leakage Leakage Limit Leakage Units 7/10/2002 LKO Sat 0
5 GPM 7/11/2004 LKO Sat 0.25 5
GPM 10/20/2004 LKO Sat 0
5 GPM 7/7/2006 LKO Sat 0.5 5
GPM 10/31/2006 LKO Sat 0.255 5
GPM 10/9/2008 LKO Sat 0
5 GPM 8/20/2010 LKO Sat 0.26 5
GPM 10/1/2012 LKO Sat 0
5 GPM 1/25/2017 LKO Sat 0.1 5
GPM