RESULAi ORY INFORMATION DISTRIBUTE SYSTEM'RIDS)

ACCESSIONi NBR: 8110960305i DOC ~ DA~TEi: 81/09/28 NOITARI ZKO:: NO DOCKEA'!

FACILC50; 389 Sty" LUciei P'lant<. Undt. 2i. Flor ida Powei Liigh't> C'o. 0'5090389 8

"AUTHi,NAMEI AUTHORl AF F ILIIATiION" OVEN r H' S "8 F l orridar Statal of RECIP ~ AAMKl RECiIPZKNT AFFILIATION EiISENHUTiPD ~ G ~ Division of Licensing SUBJECiT:: Subtolits'ept~ of EnvironE Regulation>> suggested changesI based onirev.iew of environ rept.Ch'anges- necessitatedI'oy plank de'signI changes wh'ich occurrred since" CP was granted.,

DISTRISVTiION CODEL'OORS COPIES RECEEVED: LITR L'NCLi P'IZE": ' ' '

Ehvir on ~ Comlnehts'.. 'iITLEl:E NOTES'::

RECIPXENT'Di COPIES RECIPIENT COPIEB CODE/NAMKl LTq'R KNCLl IDI CODE/NAME~ L6'TRI ENCL>

ACTiI ON:: LC CI BR" 03I BC 0 NERSES'pV ~ 05 ACCiIDNTl EVAL

'1 EF TREAT SYS 15~

6'NTERNALc 1

HYDRO GEO BR 21 19'NV ENG BR 16'8 1

El 13( 2*

RADAR ASSESS BRi17 REG F SI'Tl ANAL< BRI 18 1 ILl FINANCE: 20 EXTERNALc ACR8 1 I.PDR'RC>>

03<

NATL' AB 2li 5 PDR NSIC 04 1 NT/I S 02'c~

TOil AL'URBERi OF COP'IES REQUIRED o LiTTR 29 ENCLI

1 ll 0"

tl II m,

C

STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTALREGULATION t

BOB GRAHAM TWIN TOWERS OFFICE BUILDING ~gE GOVERNOR 2600 BLAIR STONE ROAD TALLAHASSEE,'LORIDA32301 VICTORIA J. TSCHINKEL SECRETARY 4>E Of fLO<

September 28, 1981 Mr. Darrell G. Eisenhut, Director Division of Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D. C. 20555 Re: St. Lucie Unit 2 Docket No. 50-389

Dear Mr. Eisenhut:

'he Department of Environmental Regulation (DER) has reviewed the Environmental Report for the Operational License for Florida Power 5 Light Company ( FPL) St. Lucie Plant Unit 2. The changes in plant design that have occurred since the construction license was granted requires that the state license be modified.

Review of the modified multiport diffuser indicated that a mixing zone must be designated for the thermal discharge pursuant to Section 17-3.05, florida Administrative Code in order that the discharge be in compliance with the State water quality criteria. The DER proposes to designate a. thermal mixing zone of 10.7 acre feet. Special Condition II A.2 will be changed to read.

2. Thermal Mixin Zone The heated water dis har ed from the multi ort dif-fuser shall not exceed 17 F above ambient outside of a thermal mixin zone of .10.7 acre-feet; The mixin zone shall be bounded b an area.1385.5 feet ion extendin seaward from the most landward dischar e ort 21.0 feet to either side of the dischar e i e axis and 8.0 feet sn hei ht above the bottom of the dischar e orts.

After consultation with the Environmental Protection Agency the DER will be modifying other conditions of certification dealing with effluent limitations, monitoring and sewage treatment as illustrated below.

8110060305 810'I28 3, PDR ADQCK 05000389i Protecting Florida and Your Quality of Life" C I~P.D g

s Mr. Eisenhut Page Two September 28, 1981 Condition II. B. should be modified to the following:

II.B. Chemical Liquid wastes discharges shall not contain concen-trations of pollutants aC-%he-pent-ef-disehal ge-which may-be-measured-4n-She-d~sehal ye-canal in excess of the following limitations:

1. Chlorine ( Free Available 0.2, mg/1 average)2 hr Chlorine): at condenser dischar e 0.5 mg/1 maximum a en o isc ar e canal O.l mg/1 maximum
2. Oil and Grease: 15 /1 ~i1 from low volume waste, re-o erational metal cleanin wastes, and radwaste dischar es
3. ..Polychlorinated biphenyls or other polycyclic Halogenated colllpounds: None 4-.---Geppel -2Q-ppb 6-. 4. Boron: 4 mg/1 (net) 6-.---GyekehellykamiRes~ -Q-.S-mggk
7. TSS: 30 m 1 Dail avera e 100 m 1 Dail Maximum at the dischar e from

. the low volume wastes, metal cleanin wastes and radwaste dischar es Condition III.A.l. should be modified as follows:

1. Chemical - the following parameters shall be monitored 4n the-Blake-aRdgel-disehalge and reported to the Department quarterly:

'I V

r 4

Mr. Eisenhut Page Three September 28, 1981 Parameter Sampling Type of Frequency Location Sam le Of Sam lin Flow ** Intake Pump Logs hourly Temperature ** Intake/POD hourly

-weekly

~-PQB- - -Gvab- -meRChky TSS Neutralization ~Com osite ~weekl Basin Oil and Grease PQB 8-hear -6empesNe weekly Neutralization Grab Basin Bissekved-QxygeR ~-PQB- ,

-Gvab- - --weekly Free aRd-Velar ~-PQB ~Nulti le Grabs weekly during Chlorine Residual Condenser Outlet chlorination Total Chlorine

  • POD Multi le Grabs weekl durin Residual ch orination Boron
  • POD Grab when batch dis-Charges are re-quired ***

6eppev----- -- -<-PQB- -meRChky I

  • May be monitored in discharge canal a't the location specified, in III.A.2.b.

. ** May be monitored in intake canal (Plant Intake Structure)

+** From the refueling water storage tank and nonaerated waste hold up tanks (4).

III.A.2. Thermal - The monitoring of the thermal discharge shall be accomplished by-suppkemeRCiBg-She-pvegvam-ve-qu4ed-by-%he-HPBES-Pere%-Ne-.-.-Fk9992298-ter -UR44-Ne-.

k-by-addiRg-Owe-.veeevd4Rg-Chemegvaphs as fol 1 ows:

V

/ I

Nr. Eisenhut Page Four September 28, 1981 a.) At the surface of the water a4-a-peinC-ef-maximum-sue face-4empeva4uve-ef'-a the discharge from Unit No. 2 the tern erature shall be. monitored twice annuall in Au ust an Se tember b boat or b t ermal ima e hoto-

~ra )~h.

Condition III.B. should be modified to reflect the new biological monitoring program.

Condition VIII. should be modified as follows:

D1 i ig1 9 g d p1 ih: ~E shall be collected and treated in accordance with Cha ter 17-6 FAC and DER ermits D056-34536 and, DC56-37127 or as maybe subsequently reissued or modified.

With these changes the Department of Environmental Regulation has no objection to the issuance of an Operational License to St. Lucie No. 2.

Sincerely, Hamilton S. Oven, s.8~~

Jr., P.E.

7 Administrator Power Plant Siting Section HSOjr:op cc: Charles Kaplan, EPA Robert Samworth, NRC

~ ~

I