TB to Aux Group Elevation Area open to flow (in2)

Penetration No.

DWG Line Ident No.

Pen Type Category From Building To Building End State Description Sleeve Size inches Pipe Size inches Insl Thickness in Length in Y

X Sleeve Area Below 588' in2 Pipe Area Below 588' in2 Sleeve Area Below 579' in2 Pipe Area Below 579' in2 Remarks H

553.25 113.0973 M-102, M-168. M-185 OSW-008-12" Buried Aux N Pipe Tunnel Survey & Release Service Water Supply to Diesel Generator Heat Exchangers 12 540 G

10 0.00 113.10 0.00 113.10 M-102 Goes into Diesel Gen BLD on M-106 H

554.75 113.0973 M-102, M-168. M-185 OSW-008-12" Buried Aux N Pipe Tunnel Survey & Release Service Water Supply to Diesel Generator Heat Exchangers 12 540 G

10 0.00 113.10 0.00 113.10 M-102 Goes into Diesel Gen BLD on M-106 J

555.50 7.068583 M-165, M-168, M-174 OCA-007-3" Bld to Bld Pen Aux Turbine Open Sleeve Chemical Feed 3

G 17 7.07 J

565.50 12.56637 M-165, M-174, M-168 OPW-020-4" Bld to Bld Pen Aux Turbine Open Sleeve Primary Water 4

G 17 12.57 0.00 12.57 I

568.75 12.56637 M-182, M-166 OPW-005-4" Bld to Bld Pen Aux Turbine Open Sleeve Line with Flange 4

G 24 12.57 0.00 12.57 I

568.75 7.068583 M-182,M-166 ODW-003-3" Bld to Bld Pen Aux Turbine Open Sleeve Demin Water 3

G 24 7.07 0.00 7.07 J

568.75 12.56637 M-165, M-171 2VN-001-4" Bld to Bld Pen Aux Turbine Open Sleeve Aux Bld Vents & Drains 4

G 13 J

569.75 12.56637 M-165, M-171 1VN-001-4" Bld to Bld Pen Aux Turbine Open Sleeve Aux Bld Vents & Drains 4

G 13 J

570.25 314.1593 M-165, M-174 2SW-002-20" Bld to Bld Pen Aux Turbine Open Sleeve Service Water 20 G

17 314.16 0.00 314.16 I

571.00 254.469 M-182, M-166 OCD-068-18" Bld to Bld Pen Aux Turbine Open Sleeve Condensate 18 G

24 254.47 0.00 254.47 J

571.00 28.27433 M-165, M-171 OWD-016-6" Bld to Bld Pen Aux Turbine Open Sleeve Waste Disposal 6

G 14 H

571.00 78.53982 M-165, M-187 OFP-012-10" Bld to Bld Pen Aux N Pipe Tunnel Open Sleeve Fire Protection 10 H

10 J

572.00 78.53982 M-165, M-171 OSW-056-10" Bld to Bld Pen Aux Turbine Open Sleeve Service Water 10 G

14 I

573.00 28.27433 M-182, M-166 OWD-20-6" Bld to Bld Pen Aux Turbine Open Sleeve Waste Disposal 6

G 24 28.27 0.00 28.27 J

573.25 7.068583 M-171, M-165 OWD-031-3" Bld to Bld Pen Aux Turbine Open Sleeve Waste Disposal 3

G 13 J

573.50 7.068583 M-165, M-174 OPW-0042-3" Bld to Bld Pen Aux Turbine Open Sleeve Primary Water 3

G 17 7.07 0.00 7.07 I

575.00 1017.876 M-180, M-166, OSW-019-36" Bld to Bld Pen Aux Turbine Open Sleeve Service Water Supply Header 36 720 G

23 1017.88 0.00 1017.88 J

575.00 3.141593 M-165, M-172 OWD-039-2" Bld to Bld Pen Aux Turbine Open Sleeve Waste Disposal 2

G 17 3.14 I

576.25 7.068583 M-182, M-166 OVC-071-3" Bld to Bld Pen Aux Turbine Open Sleeve Vacuum Control 3

G 24 7.07 0.00 7.07 I

586.00 452.3893 M-182, M-163 OSW-013-24" Bld to Bld Pen Aux Turbine Open Sleeve Service Water 24 G

23 J

586.00 452.3893 M-162, M-172 OSW-14-24" Bld to Bld Pen Aux Turbine Open Sleeve Service Water 24 G

17 452.39 J

586.00 3.141593 M-162, M-172 OWS-014-2" Bld to Bld Pen Aux Turbine Open Sleeve Secondary Water Sample System 2

G 17 3.14 I

588.00 12.56637 M-182, M-163 1FW-027-4" Bld to Bld Pen Aux Turbine Open Sleeve Feed Water 4

G 23 12.57 J

588.00 12.56637 M-172, M-162 2FW-027-4" Bld to Bld Pen Aux Turbine Open Sleeve Feed Water 4

G 17 12.57 I

586'6" 78.53982 M-182, M-163 OFP-003-10" Bld to Bld Pen Aux Turbine Open Sleeve Fire Protection 10 G

23