NRC RA17-040 2016 Annual Radioactive Effluent Release Report Part 11
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6 REPORTING REQUIREMENTS 12.6.1 Annual Radiological Environmental Operating Report 12.6.1.1 Routine Annual Radiological Environmental Operating Report covering the operation of the Units during the previous calendar year shall be submitted by May 15 of each year. The report shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental monitoring program for the report period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual, and in 10 CFR 50, Appendix I, Sections IV.8.2, IV.8.3, and IV.c. It should include, as found appropriate, a comparison of preoperational studies with operational controls or with previous environmental surveillance reports, and an assessment of the observed impacts of the plant operation on the environment. A single submittal may be made for a multiple unit station. The submittal should combine sections common to all units at the station.
12.6.1.2 12.6.1.3 The Annual Radiological Environmental Operating Report shall include the results of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the tables and figures in Part II, Section 6 of the ODCM, as well as summarized and tabulated results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted as soon as possible in a supplementary report.
The reports shall also include the following: a summary description of the Radiological Environmental Monitoring Program; legible maps covering all sampling locations keyed to a table giving distances and directions from the midpoint between the two units; reasons for not conducting the Radiological Environmental Monitoring Program as required by REC 12.5.1, and discussion of all deviations from the sampling schedule of Table R12.5.1-1; a Table of Missed Samples and a Table of Sample Anomalies for all deviations from the sampling schedule of ODCM Part II, Table 6.1-1; discussion of environmental sample measurements that exceed the reporting levels of Table R12.5.1-2 but are not the result of plant effluents; discussion of all analyses in which the LLD required by Table R12.5.1-3 was not achievable; results of the Land Use Census required by REC 12.5.2; and the results of licensee participation in an lnterlaboratory Comparison Program and the corrective actions being taken if the specified program is not being performed as required by REC 12.5.3.
(continued)
Page 1-12.6.1-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6 REPORTING REQUIREMENTS 12.6.1 Annual Radiological Environmental Operating Report (continued) 12.6.1.4 The Annual Radiological Environmental Operating Report shall also include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability. In lieu of submission with the Annual Radiological Environmental Operating Report, the licensee has the option of retaining the summary of required meteorological data on site in a file that shall be provided to the NRC upon request.
12.6.1.5 The Annual Radiological Environmental Operating Report shall also include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year. This report shall also include an assessment of radiation doses to the most likely exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources, including doses from primary effluent pathways and direct radiation, for the previous calendar year. The assessment of radiation doses shall be performed in accordance with the methodology and parameters in the ODCM and in compliance with 10 CFR 20 and 40 CFR 190, "Environmental Radiation Protection Standards for Nuclear Power Operation."
Page 1-12.6.1-2
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6 REPORTING REQUIREMENTS 12.6.2 Annual Radioactive Effluent Release Report 12.6.2.1 12.6.2.2 12.6.2.3 The radioactive effluent release reports covering the operation of the unit during the previous calendar year of operation shall be submitted in accordance with 10 CFR 50.36a prior to May 1 of each year. The report shall include a summary of the quantities of radioactive liquid and gaseous effluent and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and the PROCESS CONTROL PROGRAM and in conformance with 10 CFR 50.36a and 10 CFR 50, Appendix I,Section IV.B.1. A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
The radioactive effluent release reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit as outlined in Regulatory Guide 1.21, "Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," Revision 1, June 1974, with data summarized on a quarterly basis following the format of Appendix B thereof.
The radioactive effluent release report shall include the following information for each type of solid waste shipped offsite during the report period:
- 1.
Container volume,
- 2.
Total curie quantity (specify whether determined by measurement or estimate),
- 3.
Principal radionuclides (specify whether determined by measurement or estimate),
- 4.
Type of waste (e.g., spent resin, compacted dry waste, evaporator bottoms),
- 5.
Type of container (e.g., LSA, Type A, Type B, Large Quantity), and
- 6.
Solidification agent (e.g., cement, urea formaldehyde).
(continued)
Page 1-12.6.2-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6 REPORTING REQUIREMENTS 12.6.2 Radioactive Effluent Release Report (continued) 12.6.2.4 The radioactive effluent release reports shall include unplanned releases from the site to unrestricted areas of radioactive materials in gaseous and liquid effluents on a quarterly basis.
12.6.2.5 12.6.2.6 The radioactive effluent release reports shall include any changes to the PROCESS CONTROL PROGRAM (PCP) made during the reporting period.
The radioactive effluent release reports shall include a description of licensee initiated major changes to the radioactive waste treatment systems (liquid, gaseous and solid), as described in Section 12.6.3.)
Page 1-12.6.2-2
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6 REPORTING REQUIREMENTS 12.6.3 Offsite Dose Calculation Manual (ODCM) 12.6.3.1 The ODCM is common to LaSalle Unit 1 and LaSalle Unit 2. The ODCM shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm and trip setpoints, and in the conduct of the radiological environmental monitoring program; and 12.6.3.2 12.6.3.3 The ODCM shall also contain the radioactive effluent controls and radiological environmental monitoring activities, and descriptions of the information that should be included in the Annual Radiological Environmental Operating, and Radioactive Effluent Release Reports required by Technical Specifications 5.6.2 and 5.6.3.
Licensee-initiated changes to the ODCM:
- a. Shall be documented and records of reviews performed shall be retained as required by the Quality Assurance (QA) Manual. This documentation:
- 1. Shall contain sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s); and
- 2. Shall contain a determination that the change(s) maintain the level of radioactive effluent control required by 10 CFR 20.1302, 40 CFR Part 190, 10 CFR 50.36a, and 10 CFR Part 50, Appendix I, and not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations.
- 3. Shall become effective after approval of the Plant Manager.
- 4. Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change to the ODCM was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e., month and year) the change was implemented.
Page 1-12.6.3-1
12.6 REPORTING REQUIREMENTS CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls 12.6.4 Major Changes to Radioactive Waste Treatment Systems (Liquid and Gaseous) 12.6.4.1 Licensee initiated major changes to the radioactive waste treatment systems (liquid and gaseous):
- a. Shall be reported to the Commission in the Radioactive Effluent Release Report for the period in which the evaluation was reviewed by the Plant Operations Review Committee (PORC). The discussion of each change shall contain:
- 1. A summary of the evaluation that led to the determination that the change could be made in accordance with 10 CFR 50.59;
- 2. Sufficient detailed information to totally support the reason for the change without benefit or additional or supplemental information;
- 3. A detailed description of the equipment, components and processes involved and the interfaces with other plant systems;
- 4. An evaluation of the change which shows the predicted releases of radioactive materials in liquid and gaseous effluents waste that differ from those previously predicted in the license application and amendments thereto;
- 5. An evaluation of the change which shows the expected maximum exposures to individual in the unrestricted area and to the general population that differ from those previously estimated in the license application and amendments thereto;
- 6. A comparison of the predicted releases of radioactive materials, in liquid and gaseous effluents, to the actual releases for the period to when the changes are to be made;
- 7. An estimate of the exposure to plant operating personnel as a result of the change; and
- 8. Documentation of the fact that the change was reviewed and found acceptable by the PORC.
- b. Shall become effective upon review and acceptance by the PORC.
Page 1-12.6.4-1
BASES General CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls It is expected that releases of radioactive material in effluents will be kept at small fractions of the limits specified in Section 20.1302 of 10 CFR, Part 20. At the same time, the licensee is permitted the flexibility of operation, compatible with consideration of health and safety, to assure that the public is provided a dependable source of power even under unusual operating conditions which may temporarily result in releases higher than such small fractions, but still within the limits specified in Section 20.1302 of 10 CFR, Part 20. It is expected that in using this operational flexibility under unusual operating conditions the licensee will exert his best efforts to keep levels of radioactive material in effluents as low as practicable.
1-8-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) RADIOLOGICAL EFFLUENT CONTROL (REC) APPLICABILITY BASES RE Cs REC 12.0.1 REC 12.0.2 REC 12.0.1 through REC 12.0.6 establish the general requirements applicable to all RECs in Sections 12.1 through 12.5 and apply at all times, unless otherwise stated.
REC 12.0.1 establishes the Applicability statement within each individual REC as the requirement for when the REC is required to be met (i.e., when the unit is in the MODES or other specified conditions of the Applicability statement of each Requirement).
REC 12.0.2 establishes that upon discovery of a failure to meet a REC, the associated ACTIONS shall be met. The Completion Time of each Required Action for an ACTIONS Condition is applicable from the point in time that an ACTIONS Condition is entered. The Required Actions establish those remedial measures that must be taken within specified Completion Times when the requirements of a REC are not met. This Requirement establishes that:
- a.
Completion of the Required Actions within the specified Completion Times constitutes compliance with a REC; and
- b.
Completion of the Required Actions is not required when a REC is met within the specified Completion Time, unless otherwise specified.
There are two basic types of Required Actions. The first type of Required Action specifies a time limit in which the REC must be met. This time limit is the Completion Time to restore an inoperable system or component to OPERABLE status or to restore variables to within specified limits. If this type of Required Action is not completed within the specified Completion Time, a shutdown may be required to place the unit in a MODE or condition in which the REC is not applicable. (Whether stated as a Required Action or not, correction of the entered Condition is an action that may always be considered upon entering ACTIONS.) The second type of Required (continued) 1-812.0-1
BASES REC 12.0.2 (continued)
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls Action specifies the remedial measures that permit continued operation of the unit that is not further restricted by the Completion Time. In this case, compliance with the Required Actions provides an acceptable level of safety for continued operation.
Completing the Required Actions is not required when a REC is met or is no longer applicable, unless otherwise stated in the individual RECs.
The nature of some Required Actions of some Conditions necessitates that, once the Condition is entered, the Required Actions must be completed even though the associated Condition no longer exists. The individual REC's ACTIONS specify the Required Actions where this is the case. An example of this is in REC 12.4.2, "Dose from Noble Gases."
The Completion Times of the Required Actions are also applicable when a system or component is removed from service intentionally. The reasons for intentionally relying on the ACTIONS include, but are not limited to, performance of Surveillances, preventive maintenance, corrective maintenance, or investigation of operational problems. Entering ACTIONS for these reasons must be done in a manner that does not compromise safety. Intentional entry into ACTIONS should not be made for operational convenience. Additionally, if intentional entry into ACTIONS would result in redundant equipment being inoperable, alternatives should be used instead. Doing so limits the time both subsystems/divisions of a function are inoperable and limits the time conditions exist which may result in REC 12.0.3 being entered. Individual RECs may specify a time limit for performing a RSR when equipment is removed from service or bypassed for testing. In this case, the Completion Times of the Required Actions are applicable when this time limit expires, if the equipment remains removed from service or bypassed.
When a change in MODE or other specified condition is required to comply with Required Actions, the unit may enter a MODE or other specified condition in which another REC becomes applicable. In this case, the Completion Times of the associated Required Actions would apply from the point in time that the new REC becomes applicable and the ACTIONS Condition(s) are entered.
(continued) 1-812.0-2
BASES (continued)
REC 12.0.3 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls REC 12.0.3 establishes the actions that must be implemented when a REC is not met and:
- a.
An associated Required Action and Completion Time is not met and no other Condition applies; or
- b.
The condition of the unit is not specifically addressed by the associated ACTIONS. This means that no combination of Conditions stated in the ACTIONS can be made that exactly corresponds to the actual condition of the unit. Sometimes, possible combinations of Conditions are such that entering REC 12.0.3 is warranted; in such cases, the ACTIONS specifically state a Condition corresponding to such combinations and also that REC 12.0.3 be entered immediately.
Upon entering REC 12.0.3, 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is allowed to implement appropriate compensatory actions and verify the plant is not in an unanalyzed condition or that a required safety function is not compromised. Within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, Shift Operations Superintendent or designee approval of the compensatory actions and the plan for exiting REC 12.0.3 must be obtained. The use and interpretation of specified times to complete the actions of REC 12.0.3 are consistent with the discussion of Section 1.3, Completion Times.
The actions required in accordance with REC 12.0.3 may be terminated and REC 12.0.3 exited if any of the following occurs:
- a.
The REC is now met.
- b.
A Condition exists for which the Required Actions have now been performed.
- c.
ACTIONS exist that do not have expired Completion Times. These Completion Times are applicable from the point in time that the Condition is initially entered and not from the time REC 12.0.3 is exited.
(continued) 1-812.0-3
BASES REC 12.0.3 (continued)
REC 12.0.4 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls In MODES 1, 2, and 3, REC 12.0.3 provides actions for Conditions not covered in other Requirements. The requirements of REC 12.0.3 do not apply in MODES 4 and 5 because the unit is already in the most restrictive Condition. The requirements of REC 12.0.3 do not apply in other specified conditions of the Applicability (unless in MODE 1, 2, or 3) because the ACTIONS of individual RECs sufficiently define the remedial measures to be taken.
REC 12.0.4 establishes limitations on changes in MODES or other specified conditions in the Applicability when an REC is not met. It precludes placing the unit in a MODE or other specified condition stated in that Applicability (e.g., Applicability desired to be entered) when the following exist:
- a.
Unit conditions are such that the requirements of the REC would not be met in the Applicability desired to be entered; and
- b.
Continued noncompliance with the REC requirements, if the Applicability were entered, would result in the unit being required to exit the Applicability desired to be entered to comply with the Required Actions.
Compliance with Required Actions that permit continued operation of the unit for an unlimited period of time in a MODE or other specified condition provides an acceptable level of safety for continued operation. This is without regard to the status of the unit before or after the MODE change.
Therefore, in such cases, entry into a MODE or other specified condition in the Applicability may be made in accordance with the provisions of the Required Actions. The provisions of this REC should not be interpreted as endorsing the failure to exercise the good practice of restoring systems or components to OPERABLE status before entering an associated MODE or other specified condition in the Applicability.
The provisions of REC 12.0.4 shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS. In addition, the provisions of REC 12.0.4 shall not prevent (continued) 1-812.0-4
BASES REC 12.0.4 (continued)
REC 12.0.5 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls changes in MODES or other specified conditions in the Applicability that result from any unit shutdown.
Exceptions to REC 12.0.4 are stated in the individual RECs. The exceptions allow entry into MODES or other specified conditions in the Applicability when the associated ACTIONS to be entered do not provide for continued operation for an unlimited period of time. Exceptions may apply to all the ACTIONS or to a specific Required Action of a REC.
Surveillances do not have to be performed on the associated inoperable equipment (or on variables outside the specified limits), as permitted by RSR 12.0.1. Therefore, changing MODES or other specified conditions while in an ACTIONS Condition, either in compliance with REC 12.0.4, or where an exception to REC 12.0.4 is stated, is not a violation of RSR 12.0.1 or RSR 12.0.4 for those Surveillances that do not have to be performed due to the associated inoperable equipment. However, RSRs must be met to ensure OPERABILITY prior to declaring the associated equipment OPERABLE (or variable within limits) and restoring compliance with the affected REC.
REC 12.0.4 is only applicable when entering MODE 3 from MODE 4, MODE 2 from MODE 3 or 4, or MODE 1 from MODE 2. Furthermore, REC 12.0.4 is applicable when entering any other specified condition in the Applicability only while operating in MODE 1, 2, or 3. The requirements of REC 12.0.4 do not apply in MODES 4 and 5, or in other specified conditions of the Applicability (unless in MODE 1, 2, or 3) because the ACTIONS of individual Requirements sufficiently define the remedial measures to be taken.
REC 12.0.5 establishes the allowance for restoring equipment to service under administrative controls when it has been removed from service or declared inoperable to comply with ACTIONS. The sole purpose of this Requirement is to provide an exception to REC 12.0.2 (e.g., to not comply with the applicable Required Action(s)) to allow the performance of required testing to demonstrate:
- a.
The OPERABILITY of the equipment being returned to service; or (continued) 1-812.0-5
BASES REC 12.0.5 (continued)
REC 12.0.6
- b.
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls The OPERABILITY of other equipment.
The administrative controls ensure the time the equipment is returned to service in conflict with the requirements of the ACTIONS is limited to the time absolutely necessary to perform the required testing to demonstrate OPERABILITY. This Requirement does not provide time to perform any other preventive or corrective maintenance.
An example of demonstrating the OPERABILITY of other equipment is taking an inoperable channel or trip system out of the tripped condition to prevent the trip function from occurring during the performance of required testing on another channel in the other trip system. A similar example of demonstrating the OPERABILITY of other equipment is taking an inoperable channel or trip system out of the tripped condition to permit the logic to function and indicate the appropriate response during the performance of required testing on another channel in the same trip system.
REC 12.0.6 establishes the applicability of each REC to both Unit 1 and Unit 2 operation. Whenever a requirement applies to only one unit, or is different for each unit, this will be identified in the appropriate section of the REC (e.g., Applicability, RSR, etc.) with parenthetical reference, Notes, or other appropriate presentation within the body of the requirement.
1-812.0-6
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.0 ODCM RADIOLOGICAL SURVEILLANCE REQUIREMENT (RSR) APPLICABILITY BASES RS Rs RSR 12.0.1 RSR 12.0.1 through RSR 12.0.5 establish the general requirements applicable to all Requirements in 12.1 through 12.5 and apply at all times, unless otherwise stated.
RSR 12.0.1 establishes the requirement that RSRs must be met during the MODES or other specified conditions in the Applicability for which the requirements of the REC apply, unless otherwise specified in the individual RSRs. This REC is to ensure that RSRs are performed to verify the OPERABILITY of systems and components, and that variables are within specified limits. Failure to meet a RSR within the specified Frequency, in accordance with RSR 12.0.2, constitutes a failure to meet a REC.
Systems and components are assumed to be OPERABLE when the associated RSRs have been met. Nothing in this RSR, however, is to be construed as implying that systems or components are OPERABLE when:
- a.
The systems or components are known to be inoperable, although still meeting the RSRs; or
- b.
The requirements of the RSR(s) are known to be not met between required RSR performances.
RSR do not have to be performed when the unit is in a MODE or other specified condition for which the requirements of the associated REC are not applicable, unless otherwise specified.
Unplanned events may satisfy the requirements (including applicable acceptance criteria) for a given RSR. In this case, the unplanned event may be credited as fulfilling the performance of the RSR.
(continued) 1-812.0-7
BASES RSR 12.0.1 (continued)
RSR 12.0.2 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls RSRs, including RSRs invoked by Required Actions, do not have to be performed on inoperable equipment because the ACTIONS define the remedial measures that apply. RSRs have to be met and performed in accordance with RSR 12.0.2, prior to returning equipment to OPERABLE status.
Upon completion of maintenance, appropriate post maintenance testing is required to declare equipment OPERABLE. This includes ensuring applicable RSRs are not failed and their most recent performance is in accordance with RSR 12.0.2. Post maintenance testing may not be possible in the current MODE or other specified conditions in the Applicability due to the necessary unit parameters not having been established. In these situations, the equipment may be considered OPERABLE provided testing has been satisfactorily completed to the extent possible and the equipment is not otherwise believed to be incapable of performing its function. This will allow operation to proceed to a MODE or other specified condition where other necessary post maintenance tests can be completed.
RSR 12.0.2 establishes the requirements for meeting the specified Frequency for RSRs and any Required Action with a Completion Time that requires the periodic performance of the Required Action on a "once per... "
interval.
RSR 12.0.2 permits a 25% extension of the interval specified in the Frequency. This extension facilitates RSR scheduling and considers plant operating conditions that may not be suitable for conducting the RSR (e.g.,
transient conditions or other ongoing RSR or maintenance activities).
The 25% extension does not significantly degrade the reliability that results from performing the RSR at its specified Frequency. This is based on the recognition that the most probable result of any particular RSR being performed is the verification of conformance with the RSRs.
As stated in RSR 12.0.2, the 25% extension also does not apply to the initial portion of a periodic Completion Time that requires performance on a "once per... " basis. The 25% extension applies to each performance after the initial performance. The initial performance of the Required Action, (continued) 1-812.0-8
BASES RSR 12.0.2 (continued)
RSR 12.0.3 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls whether it is a particular RSR or some other remedial action, is considered a single action with a single Completion Time. One reason for not allowing the 25% extension to this Completion Time is that such an action usually verifies that no loss of function has occurred by checking the status of redundant or diverse components or accomplishes the function of the inoperable equipment in an alternative manner.
The provisions of RSR 12.0.2 are not intended to be used repeatedly merely as an operational convenience to extend RSR intervals (other than those consistent with refueling intervals) or periodic Completion Time intervals beyond those specified.
RSR 12.0.3 establishes the flexibility to defer declaring affected equipment inoperable or an affected variable outside the specified limits when a RSR has not been completed within the specified Frequency. A delay period of up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or up to the limit of the specified Frequency, whichever is greater, applies from the point in time it is discovered that the RSR has not been performed in accordance with RSR 12.0.2, and not at the time that the specified Frequency was not met. This delay period provides adequate time to complete RSRs that have been missed. This delay period permits the completion of a RSR before complying with Required Actions or other remedial measures that might preclude completion of the RSR.
The basis for this delay period includes consideration of unit conditions, adequate planning, availability of personnel, the time required to perform the RSR, the safety significance of the delay in completing the required RSR, and the recognition that the most probable result of any particular RSR being performed is the verification of conformance with the requirements.
When a RSR with a Frequency based not on time intervals, but upon specified unit conditions, operating situations, or requirements of regulations (e.g., prior to each release, or in accordance with the Radioactive Liquid Waste Sampling and Analysis Program, etc.) is discovered to not have been (continued) 1-812.0-9
BASES RSR 12.0.3 (continued)
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls performed when specified, RSR 12.0.3 allows for the full delay period of up to the specified Frequency to perform the RSR. However, since there is not a time interval specified, the missed RSR should be performed at the first reasonable opportunity.
RSR 12.0.3 provides a time limit for, and allowances for the performance of, RSRs that become applicable as a consequence of MODE changes imposed by Required Actions.
Failure to comply with specified Frequencies for RSRs is expected to be an infrequent occurrence. Use of the delay period established by RSR 12.0.3 is a flexibility which is not intended to be used as an operational convenience to extend RSR intervals. While up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or the limit of the specified Frequency is provided to perform the missed RSR, it is expected that the missed RSR will be performed at the first reasonable opportunity. The determination of the first reasonable opportunity should include consideration of the impact on plant risk (from delaying the RSR as well as any plant configuration changes required or shutting the plant down to perform the RSR) and impact on any analysis assumptions, in addition to unit conditions, planning, availability of personnel, and the time required to perform the RSR. This risk impact should be managed through the program in place to implement 10 CFR 50.65(a)(4) and its implementation guidance, NRC Regulatory Guide 1.182, "Assessing and Managing Risk Before Maintenance Activities at Nuclear Power Plants." This Regulatory Guide addresses consideration of temporary and aggregate risk impacts, determination of risk management action thresholds, and risk management action up to and including plant shutdown. The missed RSR should be treated as an emergent condition as discussed in the Regulatory Guide.
The risk evaluation may use quantitative, qualitative, or blended methods.
The degree of depth and rigor of the evaluation should be commensurate with the importance of the component. Missed RSRs for important components should be analyzed quantitatively. If the results of the risk evaluation determine the risk increase is significant, this evaluation should be used to determine the safest course of action. All missed RSRs will be placed in the station's Corrective Action Program.
(continued) 1-812.0-10
BASES RSR 12.0.3 (continued)
RSR 12.0.4 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls If a RSR is not completed within the allowed delay period, then the equipment is considered inoperable or the variable then is considered outside the specified limits and the Completion Times of the Required Actions for the applicable REC Conditions begin immediately upon expiration of the delay period. If a RSR is failed within the delay period, then the equipment is inoperable, or the variable is outside the specified limits and the Completion Times of the Required Actions for the applicable REC Conditions begin immediately upon the failure of the RSR.
Completion of the RSR within the delay period allowed by this RSR, or within the Completion Time of the ACTIONS, restores compliance with RSR 12.0.1.
RSR 12.0.4 establishes the requirement that all applicable RSRs must be met before entry into a MODE or other specified condition in the Applicability.
This RSR ensures that system and component OPERABILITY requirements and variable limits are met before entry into MODES or other specified conditions in the Applicability for which these systems and components ensure safe operation of the unit.
The provisions of this RSR should not be interpreted as endorsing the failure to exercise the good practice of restoring systems or components to OPERABLE status before entering an associated MODE or other specified condition in the Applicability.
However, in certain circumstances, failing to meet a RSR will not result in RSR 12.0.4 restricting a MODE change or other specified condition change.
When a system, subsystem, division, component, device, or variable is inoperable or outside its specified limits, the associated RSR(s) are not required to be performed per RSR 12.0.1 which states that RSRs do not have to be performed on inoperable equipment. When equipment is inoperable, RSR 12.0.4 does not apply to the associated RSR(s) since the requirement for the RSR(s) to be performed is removed. Therefore, failing to perform the RSRs within the specified Frequency, on equipment that is inoperable, does not result in a RSR 12.0.4 restriction to changing MODES or other specified conditions of the Applicability. However, since the REC is not met in this instance, REC 12.0.4 will govern any restrictions that may (or may not) apply to MODE or other specified condition changes.
(continued) 1-812.0-11
BASES RSR 12.0.4 (continued)
RSR 12.0.5 CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls The provisions of RSR 12.0.4 shall not prevent changes in MODES or other specified conditions in the Applicability that are required to comply with ACTIONS. In addition, the provisions of RSR 12.0.4 shall not prevent changes in MODES or other specified conditions in the Applicability that result from any unit shutdown.
The precise requirements for performance of RSRs are specified such that exceptions to RSR 12.0.4 are not necessary. The specific time frames and conditions necessary for meeting the RSRs are specified in the Frequency, in the RSR, or both. This allows performance of RSRs when the prerequisite condition(s) specified in a RSR procedure require entry into the MODE or other specified condition in the Applicability of the associated REC prior to the performance or completion of a RSR. A RSR that could not be performed until after entering the REC Applicability would have its Frequency specified such that it is not "due" until the specific conditions needed are met. Alternately, the RSR may be stated in the form of a Note as not required (to be met or performed) until a particular event, condition, or time has been reached. Further discussion of the specific formats of RSRs' annotation is found in Section 1.4, Frequency.
RSR 12.0.4 is only applicable when entering MODE 3 from MODE 4, MODE 2 from MODE 3 or 4, or MODE 1 from MODE 2. Furthermore, RSR 12.0.4 is applicable when entering any other specified condition in the Applicability only while operating in MODE 1, 2, or 3. The requirements of RSR 12.0.4 do not apply in MODES 4 and 5, or in other specified conditions of the Applicability (unless in MODE 1, 2, or 3) because the ACTIONS of individual Controls sufficiently define the remedial measures to be taken.
RSR 12.0.5 establishes the applicability of each RSR to both Unit 1 and Unit 2 operation. Whenever a requirement applies to only one unit, or is different for each unit, this will be identified with parenthetical reference, Notes, or other appropriate presentation within the RSR.
1-812.0-12
B 12.1 NOT USED CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls INTENTIONALLY BLANK 1-812.1-1
B 12.21NSTRUMENTATION CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.2.1 Radioactive Liquid Effluent Monitoring Instrumentation BASES The radioactive liquid effluent monitoring instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential releases of liquid effluents. The alarm/trip setpoints for these instruments shall be calculated in accordance with the procedures in the ODCM to ensure that the alarm/trip will occur prior to exceeding the limits of RECS. The OPERABILITY and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10 CFR Part 50.
1-812.2.1-1
B 12.2 INSTRUMENTATION CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.2.2 Radioactive Gaseous Effluent Monitoring Instrumentation BASES The radioactive gaseous effluent monitoring instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents. The alarm/trip setpoints for these instruments shall be calculated in accordance with the procedures in the ODCM to ensure that the alarm/trip will occur prior to exceeding the limits of RECS.
1-812.2.2-1
8 12.3LIQUID EFFLUENTS 812.3.1 Liquid Effluent Concentration BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control is provided to ensure that the concentration of radioactive materials released in liquid waste effluents from the site will be less than ten (10) times the concentration levels specified in Appendix 8, Table 2, Column 2 to 10 CFR 20.1001-2402. This limitation provides additional assurance that the levels of radioactive materials in bodies of water outside the site will result in exposure within (1) the Section II.A design objectives of Appendix I, 10 CFR 50, to an individual, and (2) the limits of 10 CFR 20.1301 to the population. In addition, this limit is associated with 40 CFR 141 which states concentration limits at the nearest downstream potable water supply. The results of the analyses of RSR 12.3.1.1, 12.3.1.2, and 12.3.1.3 shall be used with the calculational methods in the ODCM to assure that the concentrations at the point of release are maintained within the limits of this REC. Refer to Technical Specification 5.5.9.b for the definition of an outside temporary tank.
1-812.3.1-1
8.12.3 LIQUID EFFLUENTS B 12.3.2 Dose From Liquid Effluents BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control is provided to implement the requirements of Sections II.A, Ill.A and IV.A of Appendix I, 10 CFR Part 50. The REC implements the guides set forth in Section II.A of Appendix I. The ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents will be kept "as low as is reasonably achievable." Also, for fresh water sites with drinking water supplies which can be potentially affected by plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide concentrations in the finished drinking water that are in excess of the requirements of 40 CFR 141. The dose calculations in the ODCM implement the requirements in Section Ill.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of an individual through appropriate pathways is unlikely to be substantially underestimated. The equations specified in the ODCM for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I," April 1977.
This control applies to the release of radioactive materials in liquid effluents from each reactor at the site. For units with shared radwaste treatment systems, the liquid effluents from the shared systems are proportioned among the units sharing that system.
1-812.3.2-1
B 12.3LIQUID EFFLUENTS B 12.3.3 Liquid Radwaste Treatment Systems BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls The OPERABILITY of the liquid radwaste treatment system ensures that this system will be available for use whenever liquid effluents require treatment prior to release to the environment. The requirement that the appropriate portions of this system be used when specified provides assurance that the releases of radioactive materials in liquid effluents will be kept "as low as is reasonably achievable." A system bypass allows connection to portable waste treatment equipment. This enables the efficient processing of liquid radwaste through the use of state-of-the-art radwaste processing technology. The portable radwaste treatment system may be used in lieu of various portions of the liquid radwaste treatment system. When a portable waste treatment is not used, RSR 12.3.3.2 may be extended to 180 days. This control implements the requirements of 10 CFR Part 50.36a. General Design Criterion 50 of Appendix A to 10 CFR Part 50 and the design objective given in Section 11.0 of Appendix I to 10 CFR Part
- 50. The specified limits governing the use of appropriate portions of the liquid radwaste treatment system were specified as a suitable fraction of the dose design objectives set forth in Section II.A of Appendix I, 10 CFR Part 50, for liquid effluents. This specification implements Technical Specification Section 5.5.4.f for liquid effluents.
Page 1-812.3.3-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.1 Gaseous Effluent Dose Rates BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control is provided to ensure that the dose at any time at the site boundary from gaseous effluents from all units on the site will be within the annual dose limits of RECS for unrestricted areas.
These limits provide reasonable assurance that radioactive material discharged in gaseous effluents will not result in the exposure of an individual in an unrestricted area, either within or outside the site boundary exceeding the limits specified in 10 CFR 20.1301. For individuals who may at times be within the site boundary, the occupancy of the individual will be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the site boundary. The specified release rate limits restrict, at all times, the corresponding gamma and beta dose rates above background to an individual at or beyond the site boundary to less than or equal to a dose rate of 500 mrem/year to the total body or to less than or equal to a dose rate of 3000 mrem/year to the skin. These release rate limits also restrict, at all times, the corresponding thyroid dose rate above background via the inhalation pathway to less than or equal to a dose rate of 1500 mrem/year.
This control applies to the release of radioactive effluents in gaseous effluents from all reactors at the site. For units within shared radwaste treatment systems, the gaseous effluents from the shared system are proportioned among the units sharing that system.
Page 1-812.4.1-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.2 Dose from Noble Gases BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control is provided to implement the requirements of Sections 11.B, Ill.A and IV.A of Appendix I, 10 CFR Part 50. The Operability Requirements are the guides set forth in Section 11.B of Appendix I. The ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in gaseous effluents will be kept "as low as is reasonably achievable." The Surveillance Requirements implement the requirements in Section Ill.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of an individual through appropriate pathways is unlikely to be substantially underestimated. The dose calculations established in the ODCM for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I, "Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water Cooled Reactors," Revision 1, July 1977. The ODCM equations provided for determining the air doses at the site boundary are based upon the historical average atmospheric conditions Page 1-812.4.2-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.3 BASES Dose from lodine-131, lodine-133, Tritium and Radioactive Materials in Particulate Form The control is provided to implement the requirements of Sections 11.C, Ill.A and IV.A of Appendix I, 10 CFR Part 50. The operability requirements are the guides set forth in Section 11.C of Appendix I. The ACTION statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable." The ODCM calculational methods specified in the Surveillance Requirements implement the requirements in Section Ill.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of an individual through appropriate pathways is unlikely to be substantially underestimated. The ODCM calculational methods for calculating the doses due to the actual release rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50, Appendix I, "Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors," Revision 1, July 1977. These equations also provide for determining the actual doses based upon the historical average atmospheric conditions. The release rate specifications for radioiodines, radioactive materials in particulate form and radionuclides other than noble gases are dependent on the existing radionuclide pathways to man, in the unrestricted area. The pathways which were examined in the development of these calculations were:
- 1) individual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.
Page 1-812.4.3-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.4 GASEOUS RADWASTE TREATMENT (OFF-GAS) SYSTEM BASES The OPERABILITY of the GASEOUS RADWASTE TREATMENT SYSTEM ensures that the system will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable". This specification implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section 11.0 of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the systems were specified as a suitable fraction of the dose design objectives set forth in Sections 11.B and 11.C of Appendix I, 10 CFR Part 50, for gaseous effluents.
Page 1-812.4.4-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.5 VENTILATION EXHAUST TREATMENT SYSTEM BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls The OPERABILITY of the VENTILATION EXHAUST TREATMENT SYSTEM ensures that the system will be available for use whenever gaseous effluents require treatment prior to release to the environment. The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable". This specification implements the requirements of 10 CFR Part 50.36a, General Design Criterion 60 of Appendix A to 10 CFR Part 50, and the design objectives given in Section 11.0 of Appendix I to 10 CFR Part 50. The specified limits governing the use of appropriate portions of the systems were specified as a suitable fraction of the dose design objectives set forth in Sections 11.B and 11.C of Appendix I, 10 CFR Part 50, for gaseous effluents. This control implements Technical Specification 5.5.4.f for gaseous effluents.
Page 1-812.4.5-1
B 12.4 GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.6 MARK II CONTAINMENT BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control provides reasonable assurance that releases from drywell purging operations will not exceed the annual dose limits of 10 CFR 20 for unrestricted areas.
Based on definition, VENTING would not release a volume resulting in significant contribution to gaseous plant effluents, nor resultant offsite dose. As such, there is no ODCM requirement for sampling. Sampling is required for PURGING, however, since the entire drywell volume is potentially released. Sampling prior to conducting a drywell PURGE provides a pre-release check to ensure release limits will not be exceeded, and allows for the subsequent calculation of offsite dose as a result of the drywell purge.
Once the Unit is sub-critical following shutdown, the initial 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> purge will exchange multiple volumes of the drywell removing the pre-existing noble gas concentration, and the lack of any source term will yield no new concentration. Likewise, there will be no source term until criticality has been achieved following startup.
Page 1-812.4.6-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.7 Total Dose BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control is provided to meet the dose limitations of 40 CFR 190. The specification requires the preparation and submittal of a report whenever the calculated doses from plant radioactive effluents exceed twice the design objective doses of Appendix I. For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a member of the public will exceed the dose limits of 40 CFR 190 if the individual reactors remain within the reporting requirement level. The report will describe a course of action that should result in the limitation of dose to a member of the public for 12 consecutive months to within the 40 CFR 190 limits. For the purpose of the report, it may be assumed that the dose commitment to the member of the public from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 5 miles must be considered. If the dose to any member of the public is estimated to exceed the requirements of 40 CFR 190, the report with a request for a variance (provided the release conditions resulting in violation of 40 CFR 190 have not already been corrected), in accordance with the provisions of 40 CFR 190.11, is considered to be a timely request and fulfills the requirements of 40 CFR 190 until NRC staff action is completed. The variance only relates to the limits of 40 CFR 190, and does not apply in any way to the requirements for dose limitation of 10 CFR Part 20, as addressed in other sections of the RECS. An individual is not considered a member of the public during any period in which he/she is engaged in carrying out any operation that is part of the nuclear fuel cycle.
Page 1-812.4.7-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.8 Main Condenser BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control provides reasonable assurance that the releases from the main condenser will not exceed the requirements of the LaSalle Technical Specifications 3.7.6. In addition, a sample is required within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> if the increase is not due to thermal power changes. If the cause is known and not fuel related and less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in duration, then no sample is required. [This is based on a letter from W. R. Huntington to Operating Engineers, Shift Engineers and F.R. Lawless, dated May 24, 1984.)
Page 1-812.4.8-1
B 12.4GASEOUS EFFLUENTS AND TOTAL DOSE B 12.4.9 Dose Limits for MEMBERS OF THE PUBLIC BASES CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls This control applies to direct exposure of radioactive materials as well as radioactive materials released in gaseous and liquid effluents. 10 CFR 20.1301 sets forth the 100 mrem/year dose limit to members of the public; 2 mrem in any one-hour limit in the unrestricted area; and reiterates that the licensee is also required to meet the 40 CFR 190 standards. 10 CFR 20.1302 provides options to determine compliance to 10 CFR 20.1301. Compliance to the above operability requirement is based on 10 CFR 20, 40 CFR 190 and LaSalle Station Technical Specification 5.5.4.g. The Effluents Program shall implement monitoring, sampling, and analysis of radioactive liquid and gaseous effluents in accordance with 10 CFR 20.1302 and with the methodology and parameters of the ODCM.
Page 1-812.4.9-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.5RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM B 12.5.1 Radiological Environmental Monitoring Program BASES The Radiological Environmental Monitoring Program required by this section provides representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the station operation. This monitoring program implementsSection IV.B.2 of Appendix I to 10 CFR Part 50 and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Guidance for this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring.
The initially specified monitoring program will be effective for at least the first 3 years of commercial operation. Following this period, program changes may be initiated based on operational experience.
The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs). The LLDs required by Table R 12.5.1-3 are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as a before the fact limit representing the capability of a measurement system and not as an after the fact limit for a particular measurement.
Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, LA., "Limits for Qualitative Detection and Quantitative Determination -Application to Radiochemistry," Anal. Chem.
40, 586-93 (1968), and Hartwell, J.K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).
Table R12.5.1-1 requires "one sample of each community drinking water supply downstream of the plant within 10 kilometers." Drinking water supply is defined as water taken from rivers, lakes, or reservoirs (not well water) that is used for drinking.
Page 1-812.5.1-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.5RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM B 12.5.2 Land Use Census BASES This control is provided to ensure that changes in the use of areas at and beyond the SITE BOUNDARY are identified and that modifications to the Radiological Environmental Monitoring Program given in the ODCM are made if required by the results of this census.
This census satisfies the requirements of Section IV.B.3 of Appendix I to 10 CFR Part 50.
An annual garden census will not be required since the licensee will assume that there is a garden at the nearest residence in each sector for dose calculations.
Page 1-812.5.2-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.5RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM B 12.5.3 lnterlaboratory Comparison Program BASES The requirement for participation in an lnterlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental samples matrices are performed as part of the quality assurance program for environmental monitoring in order to demonstrate that the results are valid forthe purposes of Section IV.8.2 of Appendix I to 10 CFR Part 50.
Page 1-812.5.3-1
CY-LA-170-301 Revision 8 June 2016 Part I, Radiological Effluent Controls B 12.SRADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM B 12.5.4 Meteorological Monitoring Program (NOT APPLICABLE)
Page 1-812.5.4-1
CY-LA-170-301 Revision 8 June 2016 I Part II, Offsite Dose Calculation Manual OFFSITE DOSE CALCULATION MANUAL LASALLE STATION Units 1and2
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
1.0 INTRODUCTION
- ODCM GENERAL INFORMATION The Offsite Dose Calculation Manual (ODCM) presents a discussion of the following:
The basic concepts applied in calculating offsite doses from plant effluents.
The regulations and requirements for the ODCM and related programs.
The methodology and parameters for the offsite dose calculations to assess impact on the environment and compliance with regulations.
The methodology detailed in this manual is intended for the calculation of radiation doses during routine (i.e., non-accident) conditions. The calculations are normally performed using a computer program. Manual calculations may be performed in lieu of the computer program.
The dose effects of airborne radioactivity releases predominately depend on meteorological conditions (wind speed, wind direction, and atmospheric stability). For airborne effluents, the dose calculations prescribed in this manual are based on historical average atmospheric conditions. This methodology is appropriate for estimating annual average dose effects and is stipulated in the Bases Section of the Radiological Effluents Controls (RECS).
1.1 Structure of the ODCM Part I of the ODCM is considered to be the Radiological Effluents Controls (RECS), and contains the former Radiological Effluent Technical Specifications that have been removed from the Technical Specifications. Part I is organized as follows:
1-Definitions 2-Not Used 3-Controls 4-Surveillance Requirements (Note: Sections 3 and 4 are presented together as 3/4)
- 0. Control and Surveillance Requirements
- 1. Radioactive Liquid Effluent Monitoring Instrumentation
- 2. Radioactive Gaseous Effluent Monitoring Instrumentation
- 3. Radioactive Liquid Effluents
- 4. Radioactive Gaseous Effluents
- 5. Total Dose
- 6. Radiological Environmental Monitoring Program
- 7. Land Use Census
- 8. Inter-Laboratory Comparison Program
- 9. Meteorological Monitoring Program 5-Bases 6-Administrative Requirements Page 11.1-1 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Part II of the ODCM is considered to be the Offsite Dose Calculation Manual (ODCM), and contains methods, equations, assumptions, and parameters for calculation of radiation doses from plant effluents. Part II is organized as follows:
1-Introduction 2-Instrumentation and Systems 3-Liquid Effluents 4-Gaseous Effluents 5-Total Dose 6-Radiological and Environmental Monitoring Program 1.2 Regulations This section serves to illustrate the regulations and requirements that define and are applicable to the ODCM. Any information provided in the ODCM concerning specific regulations are not a substitute for the regulations as found in the Code of Federal Regulations (CFR) or Technical Specifications.
1.2.1 Code of Federal Regulations Various sections of the Code of Federal Regulations (CFR) require nuclear power stations to be designed and operated in a manner that limits the radiation exposure to members of the public. These sections specify limits on offsite radiation doses and on effluent radioactivity concentrations and they also require releases of radioactivity to be "As Low As Reasonably Achievable". These requirements are contained in 10CFR20, 10CFR50 and 40CFR190. In addition, 40CFR141 imposes limits on the concentration of radioactivity in drinking water provided by the operators of public water systems.
1 OCFR20. Standards for Protection Against Radiation This revision of the ODCM addresses the requirements of 1 OCFR20. The 1 OCFR20 dose limits are summarized in Table 1 - 1.
Design Criteria (Appendix A of 1 OCFR50)
Section 50.36 of 1 OCFR50 requires that an application for an operating license include proposed Technical Specifications. Final Technical Specifications for each station are developed through negotiation between the applicant and the NRG. The Technical Specifications are then issued as a part of the operating license, and the licensee is required to operate the facility in accordance with them.
Section 50.34 of 10CFR50 states that an application for a license must state the principal design criteria of the facility. Minimum requirements are contained in Appendix A of 1 OCFR50.
Page 11.1-2 LaSalle Part II Section 1
ALARA Provisions (Appendix I of 1 OCFR50)
CY-LA-170-301 Revision 8 June 2016 Part 11, Offsite Dose Calculation Manual Sections 50.34a and 50.36a of 1 OCFR50 require that the nuclear plant design and the station RECS have provisions to keep levels of radioactive materials in effluents to unrestricted areas "As Low As Reasonably Achievable" (ALARA). Although 1 OCFR50 does not impose specific limits on releases, Appendix I of 1 OCFR50 does provide numerical design objectives and suggested limiting conditions for operation. According to Section I of Appendix I of 10CFR50, design objectives and limiting conditions for operation, conforming to the guidelines of Appendix I "shall be deemed a conclusive showing of compliance with the "As Low As Reasonably Achievable" requirements of 1 OCFR50.34a and 50.36a."
An applicant must use calculations to demonstrate conformance with the design objective dose limits of Appendix I. The calculations are to be based on models and data such that the actual radiation exposure of an individual is "unlikely to be substantially underestimated" (see 1 OCFR50 Appendix I, Section 111.A.1 ).
The guidelines in Appendix I call for an investigation, corrective action and a report to the NRC whenever the calculated dose due to the radioactivity released in a calendar quarter exceeds one-half of an annual design objective. The guidelines also require a surveillance program to monitor releases, monitor the environment and identify changes in land use.
40CFR190. Environmental Radiation Protection Standards for Nuclear Power Operations Under an agreement between the NRC and the EPA, the NRC stipulated to its licensees in Generic Letter 79-041 that "Compliance with Radiological Effluent Technical Specifications (RETS), NUREG-0473 (Rev.2) for BWR's, implements the LWR provisions to meet 40CFR190". (See Reference 103 and 49.)
The regulations of 40CFR190 limit radiation doses received by members of the public as a result of operations that are part of the uranium fuel cycle.
Operations must be conducted in such a manner as to provide reasonable assurance that the annual dose equivalent to any member of the public due to radiation and to planned discharges of radioactive materials does not exceed the following limits:
o 25 mrem to the total body o
75 mrem to the thyroid o 25 mrem to any other organ Page 11.1-3 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual An important difference between the design objectives of 1 OCFRSO and the limits of 40CFR190 is that 10CFR50 addresses only doses due to radioactive effluents. 40CFR190 limits doses due to effluents and to radiation sources maintained on site. See Section 1.2.4 for further discussion of the differences between the requirements of 1 OCFRSO Appendix I and 40CFR 190.
40CFR141. National Primary Drinking Water Regulations The following radioactivity limits for community water systems were established in the July, 1976 Edition of 40CFR 141:
o Combined Ra-226 and Ra-228: ~ 5 pCi/L.
o Gross alpha (particle activity including Ra-226 but excluding radon and uranium): ~ 15 pCi/L.
o The average annual concentration of beta particle and photon radioactivity from man-made radionuclides in drinking water shall not produce an annual dose equivalent to the total body or any internal organ greater than 4 mrem/yr.
The regulations specify procedures for determining the values of annual average radionuclide concentration that produce an annual dose equivalent of 4 mrem. Radiochemical analysis methods are also specified. The responsibility for monitoring radioactivity in a community water system falls on the supplier of the water. The LaSalle Station has requirements related to 40CFR141 in the RECS.
1.2.2 Radiological Effluent Technical Standards The Radiological Effluent Technical Standards (RETS) were formerly a subset of the Technical Specifications. They implement provisions of the Code of Federal Regulations aimed at limiting offsite radiation dose. The NRC published Standard RETS for BWRs (Reference 3) as guidance to assist in the development of technical specifications. These documents have undergone frequent minor revisions to reflect changes in plant design and evolving regulatory concerns. The RETS have been removed from the Technical Specifications and placed in the ODCM as the RECS (see Reference 90). The RECS are similar but not identical to the guidance of the Standard Radiological Effluent Technical Specifications.
Page 11.1-4 LaSalle Part II Section 1
1.2.3 Offsite Dose Calculation Manual CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual The NRC in Generic Letter 89-01 defines the ODCM as follows (not verbatim) (see Reference 90):
The Offsite Dose Calculation Manual (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring Alarm!Trip Setpoints, and in the conduct of the Radiological Environmental Monitoring Program. The ODCM shall also contain (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs and (2) descriptions of the Information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports.
Additional requirements for the content of the ODCM are contained throughout the text of the RECS.
1.2.4 Overlapping Requirements In 10CFR20, 10CFR50 and 40CFR190, there are overlapping requirements regarding offsite radiation dose and dose commitment to the total body. In 1 OCFR20.1301, the total effective dose equivalent (TEDE) to a member of the public is limited to 100 mrem per calendar year. In addition, Appendix I to 1 OCFR50 establishes design objectives on annual total body dose or dose commitment of 3 mrem per reactor for liquid effluents and 5 mrem per reactor for gaseous effluents (see 10CFR50 Appendix I, Sections II.A and ll.B.2(a)).
Finally, 40CFR190 limits annual total body dose or dose commitment to a member of the public to 25 mrem due to all uranium fuel cycle operations.
While these dose limits/design objectives appear to overlap, they are different and each is addressed separately by the RETS. Calculations are made and reports are generated to demonstrate compliance to all regulations. Refer to Table 1 - 1 and Table 1 - 2 for additional information regarding instantaneous effluent limits, design objectives and regulatory compliance.
Page 11.1-5 LaSalle Part II Section 1
1.2.5 Dose Receiver Methodology CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Table 1 - 2 lists the location of the dose recipient and occupancy factors, if applicable. Dose is assessed at the location in the unrestricted area where the combination of existing pathways and receptor age groups indicates the maximum potential exposures. The dose calculation methodology is consistent with the methodology of Regulatory Guide 1.109 (Reference 6) and NU REG 0133 (Reference 14). Dose is therefore calculated to a maximum individual.
The maximum individual is characterized as "maximum" with regard to food consumption, occupancy and other usage of the area in the vicinity of the plant site. Such a "maximum individual" represents reasonable deviation from the average for the population in general. In all physiological and metabolic respects, the maximum individual is assumed to have those characteristics that represent averages for their corresponding age group. Thus, the dose calculated is very conservative compared to the "average" (or typical) dose recipient who does not go out of the way to maximize radioactivity uptakes and exposure.
Page 11.1-6 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Table 1 -1 Regulatory Dose Limit Matrix REGULATION DOSE TYPE DOSE LIMIT(s)
ODCM Section Airborne Releases:
(quarterly)
(annual) 10CFR50 App. I~
Gamma Dose to Air due to Noble Gas 5 mrad 10 mrad 4.2.2.1 Radionuclides (per reactor unit)
Beta Dose to Air Due to Noble Gas 10 mrad 20 mrad 4.2.2.2 Radionuclides (per reactor unit)
Organ Dose Due to Specified Non-Noble 7.5 mrem 15 mrem 4.2.3 Gas Radionuclides (per reactor unit)
Total Body and Skin Total Body 2.5 mrem 5 mrem 4.2.2.3 Dose (if air dose is exceeded)
Skin 7.5 mrem 15 mrem 4.2.2.4 Technical Specifications Total Body Dose Rate Due to Noble Gas 500 mrem/yr 4.2.1.1 Radionuclides (instantaneous limit, per site)
Skin Dose Rate Due to Noble Gas 3,000 mrem/yr 4.2.1.2 Radionuclides (instantaneous limit, per site)
Organ Dose Rate Due to Specified Non-1,500 mrem/yr 4.2.1.3 Noble Gas Radionuclides (instantaneous limit, per site)
Liquid Releases:
(quarterly)
(annual) 1 OCFR50 App. I~
Whole (Total) Body Dose 1.5 mrem 3 mrem 3.4 (per reactor unit)
Oraan Dose (per reactor unit) 5mrem 10 mrem 3.4 Technical Specifications The concentration of radioactivity in liquid Ten times the values effluents released to unrestricted areas listed in 1 OCFR20 3.2 Appendix B; Table 2, Column 2, and in note 5 below for Noble Gases Total Doses 1
10 CFR 20.1301 (a)(1)
Total Effective Dose Equivalent q 100 mrem/yr 5.2 10CFR20.1301 (d)
Total Body Dose 25 mrem/yr 5.2 And 40CFR190 Thvroid Dose 75 mrem/vr 5.2 Other Oman Dose 25 mrem/vr 5.2 Other Limits L:
40CFR141 Total Body Dose Due to Drinking Water 4 mrem/yr 3.4 From Public Water Systems Organ Dose Due to Drinking Water From 4 mrem/yr 3.4 Public Water Systems These doses are calculated considering all sources of radiation and radioactivity in effluents.
2 These limits are not directly applicable to nuclear power stations. They are applicable to the owners or operators of public water systems. However, the LaSalle RECS requires assessment of compliance with these limits.
3 Note that 1 OCFR50 provides design objectives, not limits.
4 Compliance with 10CFR20.1301(a)(1) is demonstrated by compliance with 40CFR190. Note that it may be necessary to address dose from on-site activity by members of the public as well.
5 Kr-85m, Kr-85, Kr-87, Kr-88, Ar-41, Xe-131m, Xe-133m, Xe-133, Xe-135m and Xe-135 allowable concentration is 2E-4, 5E-4, 4E-5, 9E-5, 7E-5, 7E-4, 5E-4, 6E-4, 2E-4 and 2E-4 µCi/ml, respectively, computed from Equation 17 of ICRP Publication 2 adjusted for infinite cloud submersion in water, and R =
0.01 rem/wk, Pw = 1.0 g/cm3, and PwlP, = 1.0.
Page 11.1-7 LaSalle Part 11 Section 1
Table 1 - 2 CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Dose Assessment Receivers Location; Occupancy if Dose Component or Pathway Different than 100%
"Instantaneous" dose rates from Unrestricted area boundary location that airborne radioactivity results in the maximum dose rate "Instantaneous" concentration limits in Point where liquid effluents enter the liquid effluents unrestricted area Annual average concentration limits for Point where liquid effluents enter the liquid effluents unrestricted area Direct dose from contained sources Receiver spends part of this time in the controlled area and the remainder at his residence or fishing nearby; occupancy factor is considered and is site-specific.
Direct dose from airborne plume Receiver is at the unrestricted area boundary location that results in the maximum dose.
Dose due to radioiodines, tritium and Receiver is at the location in the particulates with half-lives greater than unrestricted area where the combination of 8 days for inhalation, ingestion of existing pathways and receptor age groups vegetation, milk and meat, and ground indicates the highest potential exposures.
plane exposure pathways.
Ingestion dose from drinking water The drinking water pathway is considered as an additive dose component in this assessment only if the public water supply serves the community immediately adjacent to the plant.
Ingestion dose from eating fish The receiver eats fish from the receiving body of water Total Organ Doses Summation of ingestion/inhalation doses Total Dose Summation of above data (Note it may also be necessary to address dose from on-site activity by members of the public.)
Page 11.1-8 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Figure 1 - 1 illustrates some of the potential radiation exposure pathways to humans due to routine operation of a nuclear power station.
Contained Sources Liquid Effluent Releases Airborne Ffflnent LaSalle Part II Section 1 Figure 1 -1 Radiation Exposure Pathways to Humans Nuclear Power Plant Ingestion of Potable Water Ingestion of Aquatic Food Inhalation Deposition onto Vegetation Deposition onto Soil Direct Radiation Exposure Ingestion Animals Ingestion by (e.g.; cows)
Direct Radiation Exposure Page 11.1-9 Ingestion of Milk and Meat Human
1.3 Offsite Dose Calculation Parameters CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual This section contains offsite dose calculation parameter factors, or values not specific only to one of the gas, liquid, or total dose chapters. Additional parameters are provided in the Sections 2, 4 and 5 of the ODCM.
1 OCFR50 Dose Commitment Factors With the exception of H-3, the dose commitment factors for 1 OCFR50 related calculations are exactly those provided in Regulatory Guide 1.109 (Reference 6).
The following table lists the parameters and the corresponding data tables in the RG 1.109:
PATHWAY ADULT TEENAGER CHILD INFANT Inhalation RG 1.109:
RG 1.109:
RG 1.109:
RG 1.109:
Table E-7 Table E-8 Table E-9 Table E-10 Ingestion RG 1.109:
RG 1.109:
RG 1.109:
RG 1.109:
Table E-11 Table E-12 Table E-13 Table E-14 These tables are contained in Regulatory Guide 1.109 (Reference 6). Each table (E-7 through E-14) provides dose factors for seven organs for each of 73 radionuclides, and Table E-5 lists Miscellaneous Dose Assessment Factors -
Consumption Parameters. For radionuclides not found in these tables, dose factors will be derived from ICRP 2 (Reference 50) or NUREG-0172 (Reference 51). The values for H-3 are taken from NUREG-4013 (Reference 107).
1.4 References The references listed below were transferred from the previous ODCM revision that was common to all former Commonwealth Edison nuclear stations. The references not applicable to LaSalle Station have been deleted, however the numbering has been preserved for ease of reference management throughout the ODCM document; therefore, reference numbering is not sequential.
- 3.
U.S. Nuclear Regulatory Commission, Standard Radiological Effluent Technical Specifications for Boiling Water Reactors, NUREG-0473, Rev. 3, Draft, September 1982 (frequently revised).
- 4.
U.S. Nuclear Regulatory Commission, Measuring. Evaluating. and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants. Regulatory Guide 1.21. Revision 1, June 197 4.
Page 11.1-10 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part 11, Offsite Dose Calculation Manual
- 5.
U.S. Nuclear Regulatory Commission, Onsite Meteorological Programs, Regulatory Guide 1.23, Safety Guide 23, February 17, 1972.
- 6.
U.S. Nuclear Regulatory Commission, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR Part 50 Appendix I, Regulatory Guide 1.109, Rev. 1, October 1977.
- 7.
U.S. Nuclear Regulatory Commission, Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors, Regulatory Guide 1.111, Rev. 1, July 1977.
- 8.
U.S. Nuclear Regulatory Commission, Calculation of Releases of Radioactive Materials in Gaseous and Liquid Effluents from Light-Water-Cooled Power Reactors, Regulatory Guide 1.112, Rev. 0-R, April 1976; reissued May 1977.
- 9.
U.S. Nuclear Regulatory Commission, Estimating Aquatic Dispersion of Effluents from Accidental and Routine Reactor Releases for the Purpose of Implementing Appendix I, Regulatory Guide 1.113, Rev. 1, April 1977.
- 10.
U.S. Nuclear Regulatory Commission, Programs for Monitoring Radioactivity in the Environs of Nuclear Power Plants, Regulatory Guide 4.1, Rev. 1, April 1975.
- 11.
U.S. Nuclear Regulatory Commission, Preparation of Environmental Reports for Nuclear Power Stations, Regulatory Guide 4.2, Rev. 2, July 1976.
- 12.
U.S. Nuclear Regulatory Commission, Environmental Technical Specifications for Nuclear Power Plants, Regulatory Guide 4.8, Rev. 1, December 1975. (See also the related Radiological Assessment Branch Technical Position, Rev. 1, November 1979.)
- 13.
U.S. Nuclear Regulatory Commission, Quality Assurance for Radiological Monitoring Programs (Normal Operationsl--Effluent Streams and the Environment, Regulatory Guide 4.15, Rev. 1, February 1979.
- 14.
U.S. Nuclear Regulatory Commission, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants, edited by J. S. Boegli et al. NUREG-0133, October 1978.
- 15.
U.S. Nuclear Regulatory Commission, XOQDOQ: Computer Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations, J. F.
Sagendorf et al. NUREG/CR-2919, PNL-4380, September 1982.
- 16.
U.S. Nuclear Regulatory Commission, Radiological Assessment, edited by J. E. Till and H. R. Meyer, NUREG/CR-3332, ORNL-5968, September 1983.
- 17.
U.S. Nuclear Regulatory Commission, Standard Review Plan, NUREG-0800, July 1981.
Page 11.1-11 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
- 18.
U.S. Atomic Energy Commission, Meteorology and Atomic Energy 1968, edited by D. H.
Slade, TID-21940, July 1968.
- 19.
U.S. Atomic Energy Commission, Plume Rise, G. A. Briggs, TID-25075, 1969.
- 20.
U.S. Atomic Energy Commission, The Potential Radiological Implications of Nuclear Facilities in the Upper Mississippi River Basin in the Year 2000, WASH 1209, January 1973.
- 21.
U.S. Atomic Energy Commission, HASL Procedures Manual, Health and Safety Laboratory, HASL-300 (revised annually).
- 22.
U.S. Department of Energy, Models and Parameters for Environmental Radiological Assessments, edited by C. W. Miller, DOEfflC-11468, 1984.
- 23.
U.S. Department of Energy, Atmospheric Science and Power Production, edited by D.
Randerson, DOEfflC-27601, 1984.
- 24.
U.S. Environmental Protection Agency, Workbook of Atmospheric Dispersion Estimates, D. B. Turner, Office of Air Programs Publication No. AP-26, 1970.
- 25.
U.S. Environmental Protection Agency, 40CFR190 Environmental Radiation Protection Requirements for Normal Operations of Activities in the Uranium Fuel Cycle, Final Environmental Statement, EPA 520/4-76-016, November 1, 1976.
- 26.
U.S. Environmental Protection Agency, Environmental Analysis of the Uranium Fuel Cycle, EPA-520/9-73-003-C, November 1973.
- 27.
American Society of Mechanical Engineers, Recommended Guide for the Prediction of the Dispersion of Airborne Effluents, 1973.
- 28.
Eisenbud, M., Environmental Radioactivity, 3rd Edition, (Academic Press, Orlando, FL, 1987).
- 29.
Glasstone, S., and Jordan, W. H., Nuclear Power and Its Environmental Effects (American Nuclear Society, LaGrange Park, IL, 1980).
- 30.
International Atomic Energy Agency, Generic Models and Parameters for Assessing the Environmental Transfer of Radionuclides from Routine Releases, Safety Series, No. 57, 1982.
- 31.
National Council on Radiation Protection and Measurements, Radiological Assessment:
Predicting the Transport. Bioaccumulation. and Uptake by Man of Radionuclides Released to the Environment, NCRP Report No. 76, March 15, 1984.
- 32.
American National Standards Institute, Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities, ANSI N13.1-1969, February 19, 1969.
Page 11.1-12 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
- 33.
Institute of Electrical and Electronics Engineers, Specification and Performance of On-Site Instrumentation for Continuously Monitoring Radioactivity in Effluents, ANSI N13.10-1974, September 19, 1974.
- 34.
American National Standards Institute, Testing and Procedural Specifications for Thermoluminescence Dosimetry (Environmental Applications), ANSI N545-1975, August 20, 1975.
- 35.
American Nuclear Insurers, Effluent Monitoring, ANl/MAELU Engineering Inspection Criteria for Nuclear Liability Insurance, Section 5.1, Rev. 2, October 24, 1986.
- 36.
American Nuclear Insurers, Environmental Monitoring, ANl/MAELU Engineering Inspection Criteria for Nuclear Liability Insurance, Section 5.2, Rev. 1, March 23, 1987.
- 37.
American Nuclear Insurers, Environmental Monitoring Programs, ANl/MAELU Information Bulletin 86-1, June 9, 1986.
- 38.
Cember, H., Introduction to Health Physics, 2nd Edition (Pergamon Press, Elmsford, NY 1983).
- 39.
Electric Power Research Institute, Guidelines for Permanent BWR Hydrogen Water Chemistry lnstallations--1987 Revision, EPRI NP-5283-SR-A, Special Report, September 1987.
- 40.
Commonwealth Edison Company, Information Relevant to Keeping Levels of Radioactivity in Effluents to Unrestricted Areas As Low As Reasonably Achievable.
LaSalle County Station. Units 1 and 2, June 4, 1976.
- 41.
U.S. Nuclear Regulatory Commission, Branch Technical Position, Radiological Assessment Branch, Revision 1, November 1979. (This is a branch position on Regulatory Guide 4.8.)
- 44.
U.S. Nuclear Regulatory Commission, Calculation of Releases of Radioactive Materials in Gaseous and Liquid Effluents from Boiling Water Reactors (BWR-GALE Code),
NUREG-0016, April 1976.
- 45.
Sargent & Lundy, N-16 Skyshine from BWR Turbine Systems and Piping, NSLD Calculation No. D2-2-85, Rev. 0, 2/1/85.
- 47.
Sargent & Lundy Calculation ATD-0139, Rev. 0, N-16 Skyshine Ground Level Dose from LaSalle Turbine Systems and Piping, July 28, 1992.
- 49.
U.S. Nuclear Regulatory Commission, Methods for Demonstrating LWR Compliance with the EPA Uranium Fuel Cycle Standard (40 CFR Part 190), NUREG-0543, February 1980.
Page 11.1 -13 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
- 50.
International Commission on Radiological Protection, Report of Committee Two on Permissible Dose for Internal Radiation, Recommendations of the International Commission on Radiological Protection, ICRP Publication 2, 1959.
- 51.
U.S. Nuclear Regulatory Commission, Age-Specific Radiation Dose Commitment Factors for a One-Year Chronic Intake, Battelle Pacific Northwest Laboratories, NUREG-0172, 1977.
- 52.
W. C. Ng, Transfer Coefficients for Prediction of the Dose to Man via the Forage-Cow-Milk Pathway from Radionuclides Released to the Biosphere, UCRL-51939.
- 53.
E. C. Eimutis and M. G. Konicek, Derivations of Continuous Functions for the Lateral and Vertical Atmospheric Dispersion Coefficients, Atmospheric Environment 6, 859 (1972).
- 54.
D. C. Kocher, Editor, Nuclear Decay Data for Radionuclides Occurring in Routine Releases from Nuclear Fuel Cycle Facilities, ORNUNUREG/TM-102, August 1977.
- 55.
R. L. Heath, Gamma-Ray Spectrum Catalog, Aerojet Nuclear Co., ANCR-1000-2, third or subsequent edition.
- 56.
S. E. Thompson, Concentration Factors of Chemical Elements in Edible Aquatic Organisms, UCRL-50564, Rev. 1, 1972.
- 57.
U.S. Nuclear Regulatory Commission, Instruction Concerning Risks from Occupational Radiation Exposure, Regulatory Guide 8.29, July 1981.
- 68.
Sargent & Lundy Calculation ATD-0183, Rev. 0, 9/25/92, Dose Information Around LaSalle DAW Sea/Land Van Storage Area.
- 70.
D. C. Kocher, Radioactivity Decay Data Tables, DOE/TIC-11026, 1981.
- 71.
J. C. Courtney, A Handbook of Radiation Shielding Data, ANS/SD-76/14, July 1976.
- 75.
Sargent & Lundy, METWRSUM, S&L Program Number 09.5.187-1.0.
- 76.
Sargent & Lundy, Comments on CECo ODCM and List of S&L Calculations, Internal Office Memorandum, P. N. Derezotes to G. R. Davidson, November 23, 1988.
- 77.
Sargent & Lundy, AZAP. A Computer Program to Calculate Annual Average Offsite Doses from Routine Releases of Radionuclides in Gaseous Effluents and Postaccident X/Q Values, S&L Program Number 09.8.054-1.7.
- 78.
National Oceanic and Atmospheric Administration, A Program for Evaluating Atmospheric Dispersion from a Nuclear Power Station, J. F. Sagendorf, NOAA Page 11.1-14 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Technical Memorandum ERL ARL-42, Air Resources Laboratory, Idaho Falls, Idaho, May 1974.
- 79.
G. P. Lahti, R. S. Hubner, and J. C. Golden, Assessment of Gamma-Ray Exposures Due to Finite Plumes, Health Physics 41, 319 (1981).
- 80.
National Council of Radiation Protection and Measurements, Ionizing Radiation Exposure of the Population of the United States. NCRP Report No. 93, September 1, 1987.
- 82.
W. R. Van Pelt (Environmental Analysts, Inc.), Letter to J. Golden (Exelon Nuclear) dated January 3, 1972.
- 83.
Electric Power Research Institute, Radiological Effects of Hydrogen Water Chemistry, EPRI NP-4011, May 1985.
- 84.
U.S. Nuclear Regulatory Commission, Draft Generic Environmental Impact Statement on Uranium Milling, NUREG-0511, April 1979.
- 85.
U.S. Environmental Protection Agency, Environmental Analysis of the Uranium Fuel Cycle. Part I - Fuel Supply, EPA-520/9-73-003-B, October 1973.
- 86.
U.S. Nuclear Regulatory Commission, Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuel in Light Water Cooled Reactors, NUREG-0002, August 1976.
- 87.
U.S. Nuclear Regulatory Commission, Demographic Statistics Pertaining to Nuclear Power Reactor Sites, NUREG-0348, Draft, December 1977.
- 88.
Nuclear News 31, Number 10, Page 69(August1988).
- 89.
General Electric Company, Irradiated Fuel Storage at Morris Operation. Operating Experience Report. January 1972 through December 1982, K. J. Eger, NED0-209698.
- 90.
U.S. Nuclear Regulatory Commission, Generic Letter 89-01, "Guidance For The Implementation of Programmatic Controls For RETS In The Administrative Controls Section of Technical Specifications and the Relocation of Procedural Details of Current RETS to the Offsite Dose Calculation Manual or Process Control Program", January 1989.
- 92.
NRC Safety Evaluation Report (SER)/ldaho Notional Engineering Laboratory Technical Evaluation Report (TER) of the Commonwealth Edison Offsite Dose Calculation Manual (ODCM), Revision O.A, December 2, 1991.
- 93.
Federal Guidance Report 11 Page 11.1-15 LaSalle Part II Section 1
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
- 95.
U.S. Nuclear Regulatory Commission, Standards for Protection Against Radiation (10CFR20).
- 96.
U.S. Nuclear Regulatory Commission, Licensing of Production and Utilization Facilities (10CFR50).
- 97.
Federal Register, Vol. 57, No. 169, Monday, August 31, 1992, page 39358.
- 98.
Miller, Charles W., Models and Parameters for Environmental Radiological Assessments, U.S. Dept. of Energy, DE8102754, 1984, pages 32, 33, 48, and 49.
- 99.
Kocher, D. C., "Dose-Rate Conversion Factors For External Exposure To Photons and Electrons", Health Physics Vol. 45, No. 3 (September), pp. 665-686, 1983.
100.
U.S. Department of Health, Education and Welfare Public Health Service, Radiological Health Handbook, January 1970.
101.
ODCM Bases and Reference Document, rev.O, November 1998.
103.
U.S. Nuclear Regulatory Commission, Generic Letter 79-041, September 17, 1979.
104.
Federal Register, Vol. 56, No. 98, Tuesday, May 21, 1991, page 23374, column 3.
106.
U.S. Nuclear Regulatory Commission, Offsite Dose Calculation Manual Guidance:
Standard Radiological Effluent Controls for Boiling Water Reactors, NUREG-1302, April 1991.
107.
U.S. Nuclear Regulatory Commission, LADTAP II - Technical Reference and Users Guide, NUREG-4013, April 1986.
108.
LaSalle Calculation L-003388, Revision 0, LaSalle IRSF Shielding Evaluations for Class B and C Waste.
109.
LaSalle Calculation L-003430, Revision 0, IRSF Design Basis Event Dose Assessment.
110.
LaSalle Calculation L-003884, Revision 0, Time to Manually Close the Off-Gas Isolation Valve to Meet the Dose Limit at the Exclusion Area Boundary.
111.
LaSalle Engineering Change EC 387237, Revision 3, Removal of Offgas Vulnerabilities on Valve 2N62-F057.
112.
LaSalle Engineering Change EC 387161, Revision 0, Removal of Offgas Vulnerabilities on Valve 1 N62-F057.
Page 11.1-16 LaSalle Part II Section 1
Table 1 - 3 CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Miscellaneous Dose Assessment Factors: Environmental Parameters Parameter Value Comment Equation Basis a fo 0.76 4-11, 4-12 A
fl 1.0 Fraction of annual intake of fresh, leafy 4-11, 4-12 A
vegetation grown locally fn 1.0 Fraction of vear animals on pasture 4-13, 4-15 A
fs 1.0 Fraction of feed from pasture when on 4-13, 4-15 A
pasture tb 262,800 30 years. Period of buildup of activity in 4-9 c
hrs or soil 9.46E8 sec t1 48 hrs or Cow Milk Pathway 4-13 A
1.73E5 sec 480 hrs Cow Meat Pathway 4-15 A
or 1.73E6 th 1440 hrs Delay time for ingestion of vegetation by 4-11 A
or man 60 days for produce 5.18E6 sec 2160 hrs Delay time for ingestion of stored feed 4-13, 4-15 A
or by animals 7.78E6 sec tl 24 hrs or Delay time for ingestion of leafy 4-11 A
8.64E4 vegetable by man sec QF 50 Cow Feed Consumption Rate 4-13, 4-14, 4-15, 8
Kg/day 4-16 r
1.0 For Iodines Fraction of deposited 4-11, 4-13, 4-15 A
particulates retained on veoetation 0.2 For Particulates 4-11, 4-13, 4-15 A
Yp 0.7 Grass Yield 4-13, 4-15 A
Kg/m2 Ys 2.0 Stored Feed Yield 4-13, 4-15 A
Kg/m2 Yv 2.0 Vegetarian Area Density 4-11 A
Kg/m2
'Aw 0.0021 hr"1 or Weathering decay constant 4-11, 4-13, 4-15 A
5.73 E-7 sec *1 H
8 gm/m 3
Absolute Atmospheric Humidity 4-12, 4-14, 4-16 D
Dw 1.0 Dilution Factor at point of withdrawal of 3-3 drinking water Page 11.1-17 LaSalle Part II Section 1
Table 1 -3 CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Miscellaneous Dose Assessment Factors: Environmental Parameters Parameter Value Comment Equation Basis a BR Breathing Rate (m" I yr}
E 1400 m3/yr Infant 3700 m3/yr Child 8000 m 3/yr Teen 8000 m 3/yr Adult E
UL Leafy Vegetation Consumption Rate (kg/yr)
O kg/yr Infant 26 Kg/yr Child 42 kg/yr Teen 64 kg/yr Adult uv Stored Vegetation Consumption (kg/yr}
E 0 kg/yr Infant 520 kg/yr Child 630 kg/yr Teen 520 kg/yr Adult U"'
Cow Milk Consumption Rate (Uyr)
E 330 Uyr Infant 330 Uyr Child 400 Uyr Teen 310 Uyr Adult UM Meat Consumption Rate (kg/yr)
E 0 kg/yr Infant 41 kg/yr Child 65 kg/yr Teen 110 kg/yr Adult u,...
Fish Consumption Rate (kg/yr)
E 0 kg/yr Infant 6.9 kg/yr Child 16 kg/yr Teen 21 kg/yr Adult uu Drinking Water Consumption Rate (Uyr}
E 330 Uyr Infant 510 Uyr Child 510 Uyr Teen 730 Uyr Adult aBasis key:
A:
Reference 6, Table E-15.
8:
Reference 6, Table E-3.
C:
The parameter tb is taken as the midpoint of plant operating life (based upon an assumed 60 year plant operating lifetime).
D:
Reference 14, Section 5.3.1.3.
E:
Reference 6, Table E-5 Page 11.1-18 LaSalle Part II Section 1
Element H
Be c
F Na Mg Al p
Cl Ar K
Ca Sc Ti v Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr Rb Sr y
Zr Nb Mo Tc Ru Rh Pd Cd In Sn Sb Ag Te I
Xe Cs Ba La Ce Pr Nd LaSalle Part II Section 1 Table 1 - 4 CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Stable Element Transfer Data Ft Meat (d/kg) 1.2E-02 1.5E-03 3.1E-02 2.9E-03 3.0E-02 1.5E-03 1.5E-02 4.6E-02 2.9E-03 NA 1.8E-02 1.6E-03 2.4E-03 3.4E-02 2.8E-01 2.4E-03 8.0E-04 4.0E-02 1.3E-02 5.3E-02 8.0E-03 3.0E-02 1.5E-02 9.1E-04 1.7E-02 7.7E-02 2.9E-03 NA 3.1E-02 6.0E-04 4.6E-03 3.4E-02 2.8E-01 8.0E-03 4.0E-01 4.0E-01 1.5E-03 5.3E-02 3.0E-02 1.5E-02 9.1E-04 5.0E-03 1.7E-02 7.7E-02 2.9E-03 NA 4.0E-03 3.2E-03 2.0E-04 1.2E-03 4.7E-03 3.3E-03 FM( Cow)
Milk (d/L) 1.0E-02 3.2E-03 1.2E-02 1.4E-02 4.0E-02 3.2E-03 1.3E-03 2.5E-02 1.4E-02 NA 7.2E-03 1.1E-02 7.5E-06 5.0E-06 1.3E-03 2.2E-03 2.5E-04 1.2E-03 1.0E-03 6.7E-03 1.4E-02 3.9E-02 1.3E-03 9.9E-05 5.0E-04 1.0E-03 2.2E-02 NA 3.0E-02 8.0E-04 1.0E-05 5.0E-06 2.5E-03 7.5E-03 2.5E-02 1.0E-06 1.0E-02 6.7E-03 2.0E-02 1.3E-03 9.9E-05 2.0E-05 5.0E-02 1.0E-03 6.0E-03 NA 1.2E-02 4.0E-04 5.0E-06 1.0E-04 5.0E-06 5.0E-06 Page 11.1-19 Reference 6
Footnote 1 6
Footnote 2 6
Footnote 1 Footnote 3 6
Footnote 2 NA 16 16 Footnote 4 Footnote 5 Footnote 6 6
6 6
6 6
6 6
Footnote 3 Footnote 7 Footnote 8 Footnote 9 F1 Footnote 2;FM from Ref. 16 NA 6
6 6
6 6
6 6
6 6
Footnote 10 Footnote 11 Footnote 3 Footnote 7 98 6
6 6
NA 6
6 6
6 6
6
CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Table 1 - 4 (Cont'd)
Stable Element Transfer Data Notes:
- 1.
- 2.
Ft FM (Cow)
Element Meat {d/kg)
Milk {d/L)
Pm 2.9E-04 2.0E-05 Sm 2.9E-04 2.0E-05 Eu 2.9E-04 2.0E-05 Gd 2.9E-04 2.0E-05 Dy 2.9E-04 2.0E-05 Er 2.9E-04 2.0E-05 Tm 2.9E-04 2.0E-05 Yb 2.9E-04 2.0E-05 Lu 2.9E-04 2.0E-05 Hf 3.4E-02 5.0E-06 Ta 2.8E-01 1.3E-03 w
1.3E-03 5.0E-04 Re 1.0E-01 1.3E-03 Os 2.2E-01 6.0E-04 Ir 7.3E-03 5.5E-03 Pt 5.3E-02 6.?E-03 Au 1.3E-02 3.2E-02 Hg 3.0E-02 9.?E-06 Tl 1.5E-02 1.3E-03 Pb 9.1E-04 9.9E-05 Bi 1.7E-02 5.0E-04 Ra 5.5E-04 5.9E-04 Th 1.6E-06 5.0E-06 u
1.6E-06 1.2E-04 Np 2.0E-04 5.0E-06 Am 1.6E-06 2.0E-05 NA = It is assumed that noble gases are not deposited on the ground.
Elements listed are those considered for 1 OCFR20 assessment and compliance.
Footnotes:
Reference 16 16 16 16 16 16 16 16 16 Footnote 5 FM - Ref.16; F1 -Footnote 6 6
FM - Ref.16; F1 -Footnote 12 Footnote 13 Footnote 14 Footnote 10 Footnote 15 FM - Ref.16; F1 -Footnote 11 FM - Ref.16; F1 -Footnote 3 98 98 98 98 98 6
98 There are numerous Fr and FM values that were not found in published literature. In these cases, the periodic table was used in conjunction with published values. The periodic table was used based on a general assumption that elements have similar characteristics when in the same column of the periodic table. The values of elements in the same column of the periodic table, excluding atomic numbers 58-71 and 90-103, were averaged then assigned to elements missing values located in the same column of the periodic table. This method was used for all columns where there were missing values except column 3A, where there was no data, hence, the average of column 2B and 4A were used.
- 1.
Values obtained by averaging Reference 6 values of Ca, Sr, Ba and Ra.
- 2.
Fr value obtained by assigning the Reference 6 value for I. FM value obtained by averaging I (Ref. 6) and Br (Ref.16).
- 3.
Fr values obtained by averaging Zn (Ref.6) and Pb (Ref. 98); there were no values for elements in the same column; an average is taken between values of columns 2B and 4A on the periodic table. FM values obtained by using the value for Tl from Reference 16.
- 4.
Values obtained by averaging Reference 6 values of Y and La.
- 5.
Values obtained by assigning the Reference 6 value for Zr.
- 6.
Fr values obtained from Ref. 6 value for Nb. FM values obtained by averaging values for Nb (Ref.6) and Ta (Ref. 16).
- 7.
Values obtained from the Reference 6 values for Pb.
- 8.
Values obtained from the Reference 6 values for Bi.
- 9.
Values obtained from the Reference 6 values for Te.
- 10.
Values obtained from the Reference 6 values for Ni.
11.
Fr values obtained from Ref. 6 values for Zn. FM values obtained by averaging the Reference 6 values for Zn and Hg.
- 12.
Values obtained by averaging Reference 6 values for Mn, Tc, Nd and Reference 98 value for U.
- 13.
Values obtained by averaging Reference 6 values from Fe and Ru.
- 14.
Values obtained by averaging Reference 6 values from Co and Rh.
- 15.
Values obtained by averaging Reference 6 values from Cu and Ag.
Page 11.1-20 LaSalle Part II Section 1
LaSalle Part II Section 1 Figure 1 -2 Unrestricted Area Boundary
'l'g=i!
a.a~ i Jin 1.J fd'I.
fl'tmit.
J
~T'~
._ ____.-....r Page 11.1-21 CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
Figure 1 - 3 Restricted Area Boundary CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual
~
i!Ulf!l!jlli... llmotft Qptii'l~ -
IL"D llJ'YWf ~
~
c,.Lw..-.
Cf'FSJ TE ~
CAtC't.ft.Jill
- Qr~
IT.ID al :c::n;a j i lR I
I.Jr. 51.U.E CD..NTI' ST l\\TlCN NB t-w-~
Page 11.1-22 LaSalle Part II Section 1