ML17117A595

From kanterella
Jump to navigation Jump to search
2016 Annual Radioactive Effluent Release Report, Part 15
ML17117A595
Person / Time
Site: LaSalle  
Issue date: 04/27/2017
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML17117A559 List:
References
RA17-040
Download: ML17117A595 (33)


Text

NRC RA17-040 2016 Annual Radioactive Effluent Release Report Part 15

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-24 (Page 1 of 4)

Infant Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 O.OOE+OO 2.65E+04 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 O.OOE+OO 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 O.OOE+OO 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 O.OOE+OO 2.03E+06 1.12E+05 7.74E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.61E+04 O.OOE+OO 1.05E+05 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 9.72E+07 4.14E+02 O.OOE+OO 5.25E+05 7.57E+05 2.37E+05 O.OOE+OO 4.98E+05 O.OOE+OO 3.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.95E+01 5.75E+01 1.32E+01 1.28E+04 3.57E+02 O.OOE+OO O.OOE+OO 2.53E+04 4.98E+03 O.OOE+OO 4.98E+03 1.00E+06 7.06E+03 O.OOE+OO 1.97E+04 1.18E+04 3.33E+03 O.OOE+OO O.OOE+OO 8.69E+04 1.1 OE+03 O.OOE+OO O.OOE+OO 1.54E+OO 2.21E-01 O.OOE+OO 1.10E+OO 1.25E+04 7.17E+04 O.OOE+OO O.OOE+OO 6.51E+02 6.41E+02 O.OOE+OO O.OOE+OO 3.79E+05 4.86E+03 O.OOE+OO O.OOE+OO 1.22E+03 1.82E+03 O.OOE+OO O.OOE+OO 7. 77E+05 1.11 E+04 O.OOE+OO 1.36E+04 2.35E+04 9.48E+03 O.OOE+OO O.OOE+OO 1.02E+06 2.48E+04 O.OOE+OO O.OOE+OO 8.02E+03 1.18E+04 O.OOE+OO O.OOE+OO 4.51 E+06 3.19E+04 O.OOE+OO 2.53E+04 7.62E+03 4.34E+03 O.OOE+OO O.OOE+OO 7.67E+04 8.88E+02 O.OOE+OO 3.39E+05 2.04E+04 1.16E+04 O.OOE+OO O.OOE+OO 2.09E+05 2.42E+03 O.OOE+OO O.OOE+OO 1.88E+OO 7.74E-01 O.OOE+OO 3.98E+OO 9.30E+03 1.50E+04 O.OOE+OO 2.39E+OO 2.84E-01 1.23E-01 O.OOE+OO O.OOE+OO 8.12E+03 5.01 E+04 O.OOE+OO 1.93E+04 6.26E+04 3.11 E+04 O.OOE+OO 3.25E+04 6.47E+05 5.14E+04 O.OOE+OO ZN-69m 1.26E+01 2.58E+01 2.34E+OO O.OOE+OO 1.04E+01 2.67E+04 4.09E+04 O.OOE+OO ZN-69 5.39E-02 9.67E-02 7.18E-03 O.OOE+OO 4.02E-02 1.47E+03 1.32E+04 O.OOE+OO SE-79 BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO 3.15E+03 5.88E+02 O.OOE+OO 3.46E+03 4.19E+05 4.84E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.33E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.40E-15 O.OOE+OO O.OOE+OO O.OOE+OO 3.81 E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.00E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.04E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.04E+03 O.OOE+OO O.OOE+OO 1.24E+05 4.93E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.37E+02 O.OOE+OO O.OOE+OO 5.57E+02 2.87E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.39E+02 O.OOE+OO O.OOE+OO 3.21 E+02 2.06E+02 O.OOE+OO O.OOE+OO O.OOE+OO 6.82E+01 O.OOE+OO 3.98E+05 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 2.03E+06 6.40E+04 O.OOE+OO 4.09E+07 O.OOE+OO 2.59E+06 O.OOE+OO O.OOE+OO 1.12E+07 1.31 E+OS O.OOE+OO 3.29E+03 O.OOE+OO 8.82E+01 O.OOE+OO O.OOE+OO 2.69E+05 1.04E+05 O.OOE+OO 9.56E+01 O.OOE+OO 3.46E+OO O.OOE+OO O.OOE+OO 5.26E+04 7.34E+04 O.OOE+OO 4.07E-01 O.OOE+OO 1.39E-02 O.OOE+OO O.OOE+OO 2. 79E+03 2.35E+03 O.OOE+OO 5.88E+05 O.OOE+OO 1.57E+04 O.OOE+OO O.OOE+OO 2.45E+06 7.03E+04 O.OOE+OO 11.4-99 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-24 (Page 2 of 4)

Infant Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 1.05E+01 O.OOE+OO 3.91 E-01 O.OOE+OO O.OOE+OO 2.38E+04 1.40E+05 O.OOE+OO 1.64E+01 O.OOE+OO 4.61 E-01 O.OOE+OO O.OOE+OO 2.45E+04 1.27E+05 O.OOE+OO 1.50E+02 O.OOE+OO 4.07E+OO O.OOE+OO O.OOE+OO 7.64E+04 1.67E+05 O.OOE+OO NB-93m 1.93E+05 5.03E+04 1.61E+04 O.OOE+OO 5.15E+04 2.93E+05 3.46E+03 O.OOE+OO NB-95 1.57E+04 6.43E+03 3. 78E+03 O.OOE+OO 4. 72E+03 4. 79E+05 1.27E+04 O.OOE+OO NB-97 3.42E-01 7.29E-02 2.63E-02 O.OOE+OO 5.70E-02 3.32E+03 2.69E+04 O.OOE+OO ZR-93 3.14E+05 1.33E+05 8.65E+04 O.OOE+OO 4.47E+05 1.92E+06 2.07E+04 O.OOE+OO ZR-95 1.15E+05 2. 79E+04 2.03E+04 O.OOE+OO 3.11 E+04 1. 75E+06 2.17E+04 O.OOE+OO ZR-97 1.50E+02 2.56E+01 1.17E+01 O.OOE+OO 2.59E+01 1.1 OE+05 1.40E+05 O.OOE+OO M0-93 O.OOE+OO 9.04E+03 3.11E+02 O.OOE+OO 2.16E+03 4.76E+05 5.26E+03 O.OOE+OO M0-99 O.OOE+OO 1.65E+02 3.23E+01 O.OOE+OO 2.65E+02 1.35E+05 4.87E+04 O.OOE+OO TC-99 2.93E+02 3.75E+02 1.24E+02 O.OOE+OO 3.49E+03 9.48E+05 1.09E+04 O.OOE+OO TC-99m 1.40E-03 2.88E-03 3.72E-02 O.OOE+OO 3.11 E-02 8.11 E+02 2.03E+03 O.OOE+OO TC-101 6.51 E-05 8.23E-05 8.12E-04 O.OOE+OO 9.79E-04 5.84E+02 8.44E+02 O.OOE+OO RU-103 2.02E+03 O.OOE+OO 6.79E+02 O.OOE+OO 4.24E+03 5.52E+05 1.61E+04 O.OOE+OO RU-105 1.22E+OO O.OOE+OO 4.10E-01 O.OOE+OO 8.99E-01 1.57E+04 4.84E+04 O.OOE+OO RU-106 8.68E+04 O.OOE+OO 1.09E+04 O.OOE+OO 1.07E+05 1.16E+07 1.64E+05 O.OOE+OO RH-105 1.16E+01 7.57E+OO 5.08E+OO O.OOE+OO 2.10E+01 2.91 E+04 1.92E+04 O.OOE+OO PD-107 O.OOE+OO 6.89E+01 5.75E+01 O.OOE+OO 3.85E+03 8.88E+04 1.03E+03 O.OOE+OO PD-109 O.OOE+OO 5.49E+OO 1.47E+OO O.OOE+OO 1.79E+01 2.35E+04 3.99E+04 O.OOE+OO AG-110m 9.98E+03 7.22E+03 5.00E+03 O.OOE+OO 1.09E+04 3.67E+06 3.30E+04 O.OOE+OO AG-111 5.25E+02 2.03E+02 1.09E+02 O.OOE+OO 4.27E+02 2.88E+05 4.23E+04 O.OOE+OO CD-113m O.OOE+OO 9.34E+05 3.70E+04 O.OOE+OO 8.12E+05 1.96E+06 2.31E+04 O.OOE+OO CD-115m O.OOE+OO 2.42E+05 8.67E+03 O.OOE+OO 1.32E+05 2.06E+06 7.03E+04 O.OOE+OO SN-123 2.93E+05 5.89E+03 1.02E+04 5.98E+03 O.OOE+OO 3.11E+06 5.71E+04 O.OOE+OO SN-125 1.41E+04 3.51E+02 8.40E+02 3.46E+02 O.OOE+OO 9.00E+05 1.02E+05 O.OOE+OO SN-126 1.16E+06 2.02E+04 4.93E+04 5.38E+03 O.OOE+OO 6.90E+06 2.31E+04 O.OOE+OO SB-124

3. 79E+04 5.56E+02 1.20E+04 1.01 E+02 O.OOE+OO 2.65E+06 5.91 E+04 O.OOE+OO SB-125 5.45E+04 4.77E+02 1.09E+04 6.23E+01 O.OOE+OO 1.64E+06 1.47E+04 O.OOE+OO SB-126 4.31E+03 8.41E+01 1.55E+02 3.29E+01 O.OOE+OO 9.63E+05 7.46E+04 O.OOE+OO SB-127 3.95E+02 7.06E+OO 1.23E+02 5.04E+OO O.OOE+OO 2.16E+05 5.29E+04 O.OOE+OO TE-125m 4.76E+03 1.99E+03 6.58E+02 1.62E+03 O.OOE+OO 4.47E+05 1.29E+04 O.OOE+OO TE-127m 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 O.OOE+OO TE-127 2.23E+OO 9.53E-01 4.89E-01 1.85E+OO 4.86E+OO 1.04E+04 2.44E+04 O.OOE+OO TE-129m 1.41E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 O.OOE+OO TE-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 O.OOE+OO TE-133m 8.58E-02 5.03E-02 3.84E-02
7. 73E-02 2.41 E-01 5.49E+03 2.23E+04 O.OOE+OO 11.4-100 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-24 (Page 3 of 4)

Infant Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 4.45E-02 2.86E-02 2.35E-02 4.07E-02 1.34E-01 4.10E+03 3.54E+03 O.OOE+OO 3.02E+04 2.23E+04 1.62E+04 1.46E+07 2.63E+04 O.OOE+OO 2.97E+02 O.OOE+OO 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 O.OOE+OO 1.99E+03 O.OOE+OO 3.79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 O.OOE+OO 1.06E+03 O.OOE+OO TE-131 m 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 O.OOE+OO TE-131 1.74E-02 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 O.OOE+OO 1-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 O.OOE+OO 1.90E+03 O.OOE+OO TE-132 3.72E+02 2.37E+02 1.76E+02 2.79E+02 1.04E+03 3.40E+05 4.41E+04 O.OOE+OO 1-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 O.OOE+OO 2.16E+03 O.OOE+OO CS-134m 1.85E+02 2.94E+02 1.55E+02 O.OOE+OO 1.19E+02 2.80E+01 1.62E+02 O.OOE+OO CS-134 3.96E+05 7.03E+05 7.45E+04 O.OOE+OO 1.90E+05 7.97E+04 1.33E+03 O.OOE+OO 1-134 9.21 E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 O.OOE+OO 1.29E+03 O.OOE+OO 1-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 O.OOE+OO 1.83E+03 O.OOE+OO CS-135 1.40E+05 1.21E+05 6.62E+03 O.OOE+OO 3.61E+04 1.41E+04 3.05E+02 O.OOE+OO CS-136 4.83E+04 1.35E+05 5.29E+04 O.OOE+OO 5.64E+04 1.18E+04 1.43E+03 O.OOE+OO CS-137 5.49E+05 6.12E+05 4.55E+04 O.OOE+OO 1.72E+05 7.13E+04 1.33E+03 O.OOE+OO CS-138 5.05E+02 7.81E+02 3.98E+02 O.OOE+OO 4.10E+02 6.54E+01 8.76E+02 O.OOE+OO CS-139 3.25E+02 4.24E+02 1.71E+02 O.OOE+OO 2.31E+02 3.54E+01 1.86E+01 O.OOE+OO BA-139 1.48E+OO 9.84E-04 4.30E-02 O.OOE+OO 5.92E-04 5.95E+03 5.10E+04 O.OOE+OO BA-140 5.60E+04 5.60E+01 2.90E+03 O.OOE+OO 1.34E+01 1.60E+06 3.84E+04 O.OOE+OO LA-140 5.05E+02 2.00E+02 5.15E+01 O.OOE+OO O.OOE+OO 1.68E+05 8.48E+04 O.OOE+OO BA-141 1.57E-01 1.0SE-04 4.97E-03 O.OOE+OO 6.50E-05 2.97E+03 4.75E+03 O.OOE+OO LA-141 6.79E+OO 1.96E+OO 3.43E-01 O.OOE+OO O.OOE+OO 1.71E+04 8.34E+04 O.OOE+OO CE-141 2.77E+04 1.67E+04 1.99E+03 O.OOE+OO 5.25E+03 5.17E+05 2.16E+04 O.OOE+OO BA-142 3.98E-02 3.30E-05 1.96E-03 O.OOE+OO 1.90E-05 1.55E+03 6.93E+02 O.OOE+OO LA-142 1.03E+OO 3.77E-01 9.04E-02 O.OOE+OO O.OOE+OO 8.22E+03 5.95E+04 O.OOE+OO CE-143 2.93E+02 1.93E+02 2.21E+01 O.OOE+OO 5.64E+01 1.16E+05 4.97E+04 O.OOE+OO PR-143 1.40E+04 5.24E+03 6.99E+02 O.OOE+OO 1.97E+03 4.33E+05 3.72E+04 O.OOE+OO CE-144 3.19E+06 1.21E+06 1.76E+05 O.OOE+OO 5.38E+05 9.84E+06 1.48E+05 O.OOE+OO PR-144 4.79E-02 1.85E-02 2.41E-03 O.OOE+OO 6.72E-03 1.61E+03 4.28E+03 O.OOE+OO ND-147 7.94E+03 8.13E+03 5.00E+02 O.OOE+OO 3.15E+03 3.22E+05 3.12E+04 O.OOE+OO PM-147 5.47E+05 4.30E+04 2.18E+04 O.OOE+OO 6.90E+04 6.37E+05 8.05E+03 O.OOE+OO PM-148m 7.00E+04 1.74E+04 1.39E+04 O.OOE+OO 2.03E+04 1.71E+06 4.72E+04 O.OOE+OO PM-148 4.68E+03 6.75E+01 3.42E+02 O.OOE+OO 8.06E+02 4.48E+05 8.46E+04 O.OOE+OO PM-149 4.34E+02 5. 71 E+01 2.49E+01 O.OOE+OO 6.94E+01 9.1 OE+04 4.21 E+04 O.OOE+OO PM-151 1.05E+02 1.54E+01 7.77E+OO O.OOE+OO 1.82E+01 4.55E+04 3.61E+04 O.OOE+OO SM-151 4.73E+05 9.03E+04 2.28E+04 O.OOE+OO 7.34E+04 4.17E+05 4.84E+03 O.OOE+OO 11.4-101 LASALLE ODCM PART II SECTION 4.doc

Table 4-24 (Page 4 of 4)

Infant Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin SM-153 2.14E+02 1.65E+02 1.27E+01 O.OOE+OO 3.46E+01 5.18E+04 2.70E+04 O.OOE+OO EU-152 1.10E+06 2.48E+05 2.41E+05 O.OOE+OO 8.32E+05 2.07E+06 1.38E+04 O.OOE+OO EU-154 4.14E+06 4.84E+05 3.43E+05 O.OOE+OO 1.60E+06 4.27E+06 3.98E+04 O.OOE+OO EU-155 8.36E+05 8.01E+04 4.84E+04 O.OOE+OO 2.21E+05 7.28E+05 7.27E+04 O.OOE+OO EU-156 2.18E+04 1.34E+04 2.16E+03 O.OOE+OO 6.27E+03 8.57E+05 5.80E+04 O.OOE+OO TB-160 1.57E+05 O.OOE+OO 1.96E+04 O.OOE+OO 4.48E+04 1.55E+06 3.00E+04 O.OOE+OO H0-166m 2.03E+05 4.30E+05 3.51E+05 O.OOE+OO 5.91E+05 2.87E+06 2.31E+04 O.OOE+OO W-181 6.80E+01 2.04E+01 2.34E+OO O.OOE+OO O.OOE+OO 1.86E+04 3.68E+02 O.OOE+OO W-185 2.20E+03 6.76E+02 7.81 E+01 O.OOE+OO O.OOE+OO 6.27E+05 1.57E+04 O.OOE+OO W-187 1.30E+01 9.02E+OO 3.12E+OO O.OOE+OO O.OOE+OO 3.96E+04 3.56E+04 O.OOE+OO NP-239

3. 71 E+02 3.32E+01 1.88E+01 O.OOE+OO 6.62E+01 5.95E+04 2.49E+04 O.OOE+OO U-232 3.60E+08 O.OOE+OO 2.98E+07 O.OOE+OO 3.36E+07 2.09E+09 6.10E+04 O.OOE+OO U-233 7.62E+07 O.OOE+OO 5.36E+06 O.OOE+OO 1.53E+07 4.98E+08 5.64E+04 O.OOE+OO U-234 7.31 E+07 O.OOE+OO 5.25E+06 O.OOE+OO 1.50E+07 4.89E+08 5.53E+04 O.OOE+OO U-235 7.01 E+07 O.OOE+OO 4.93E+06 O.OOE+OO 1.41 E+07 4.59E+08 7.03E+04 O.OOE+OO U-236 7.01 E+07 O.OOE+OO 5.04E+06 O.OOE+OO 1.44E+07 4.69E+08 5.19E+04 O.OOE+OO U-237 4.55E+02 O.OOE+OO 1.21 E+02 O.OOE+OO 1.13E+03 1.28E+05 1.83E+04 O.OOE+OO U-238 6.71E+07 O.OOE+OO 4.61E+06 O.OOE+OO 1.32E+07 4.28E+08 4.96E+04 O.OOE+OO NP-237 4.03E+09 2.39E+09 1.76E+08 O.OOE+OO 1.08E+09 4.89E+08 7.14E+04 O.OOE+OO NP-238 3.74E+03 8.47E+02 5.82E+01 O.OOE+OO 2.06E+02 1.29E+05 3.61 E+04 O.OOE+OO PU-238 3.77E+09 2.35E+09 1.78E+08 O.OOE+OO 6.50E+08 1.26E+09 6.57E+04 O.OOE+OO PU-239 4.10E+09 2.46E+09 1.88E+08 O.OOE+OO 6.93E+08 1.19E+09 5.99E+04 O.OOE+OO PU-240 4.10E+09 2.45E+09 1.88E+08 O.OOE+OO 6.92E+08 1.19E+09 6.10E+04 O.OOE+OO PU-241 1.18E+08 2.59E+07 4.35E+06 O.OOE+OO 1.61 E+07 1.07E+06 1.26E+03 O.OOE+OO PU-242 3.81 E+09 2.37E+09 1.81 E+08 O.OOE+OO 6.68E+08 1.14E+09 5.88E+04 O.OOE+OO PU-244 4.44E+09 2.72E+09 2.07E+08 O.OOE+OO 7.64E+08 1.31E+09 8.76E+04 O.OOE+OO AM-241 4.41E+09 2.73E+09 1.83E+08 O.OOE+OO 1.11E+09 5.68E+08 6.69E+04 O.OOE+OO AM-242m 4.55E+09 2.60E+09 1.89E+08 O.OOE+OO 1.12E+09 2.30E+08 8.41 E+04 O.OOE+OO AM-243 4.34E+09 2.63E+09 1.78E+08 O.OOE+OO 1.08E+09 5.39E+08 7.84E+04 O.OOE+OO CM-242 1.79E+08 1.21E+08 7.98E+06 O.OOE+OO 2.37E+07 4.16E+08 7.14E+04 O.OOE+OO CM-243 3.46E+09 2.13E+09 1.48E+08 O.OOE+OO 5.47E+08 5.94E+08 7.03E+04 O.OOE+OO CM-244 2.90E+09 1.78E+09 1.24E+08 O.OOE+OO 4.49E+08 5.71E+08 6.80E+04 O.OOE+OO CM-245 4.51E+09 2.74E+09 1.90E+08 O.OOE+OO 7.32E+08 5.49E+08 6.34E+04 O.OOE+OO CM-246 4.48E+09 2.74E+09 1.90E+08 O.OOE+OO 7.32E+08 5.59E+08 6.23E+04 O.OOE+OO CM-247 4.35E+09 2.70E+09 1.86E+08 O.OOE+OO 7.21E+08 5.49E+08 8.19E+04 O.OOE+OO CM-248 3.61E+10 2.23E+10 1.54E+09 O.OOE+OO 5.94E+09 4.52E+09 1.32E+06 O.OOE+OO CF-252 3.32E+09 O.OOE+OO 1.41 E+08 O.OOE+OO O.OOE+OO 1.92E+09 2.59E+05 O.OOE+OO 11.4-102 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-25 (Page 1 of 4)

Child Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 O.OOE+OO 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 O.OOE+OO 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 O.OOE+OO 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 1.61 E+04 O.OOE+OO 2.61 E+06 1.14E+05 9.88E+04 O.OOE+OO O.OOE+OO O.OOE+OO 4.22E+04 O.OOE+OO 2.61 E+05 O.OOE+OO 2.85E+04 O.OOE+OO O.OOE+OO 2.67E+08 1.09E+03 O.OOE+OO 7.29E+05 9.99E+05 3.85E+05 O.OOE+OO 8.84E+05 O.OOE+OO 9.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.54E+02 8.55E+01 2.43E+01 1. 70E+04 1.08E+03 O.OOE+OO O.OOE+OO 4.29E+04 9.51 E+03 O.OOE+OO 1.00E+04 1.58E+06 2.29E+04 O.OOE+OO 4.74E+04 2.52E+04 7.77E+03 O.OOE+OO O.OOE+OO 1.11E+05 2.87E+03 O.OOE+OO O.OOE+OO 1.66E+OO 3.12E-01 O.OOE+OO 1.67E+OO 1.31E+04 1.23E+05 O.OOE+OO O.OOE+OO 9.03E+02 1.07E+03 O.OOE+OO O.OOE+OO 5.07E+05 1.32E+04 O.OOE+OO O.OOE+OO 1. 77E+03 3.16E+03 O.OOE+OO O.OOE+OO 1.11 E+06 3.44E+04 O.OOE+OO 2.07E+04 3.35E+04 1.67E+04 O.OOE+OO O.OOE+OO 1.27E+06 7.07E+04 O.OOE+OO O.OOE+OO 1.31 E+04 2.26E+04 O.OOE+OO O.OOE+OO 7.07E+06 9.62E+04 O.OOE+OO 6.14E+04 1.73E+04 1.05E+04 O.OOE+OO O.OOE+OO 1.01E+05 2.33E+03 O.OOE+OO 8.21E+05 4.63E+04 2.80E+04 O.OOE+OO O.OOE+OO 2.75E+05 6.33E+03 O.OOE+OO O.OOE+OO 1.99E+OO 1.07E+OO O.OOE+OO 6.03E+OO 9.58E+03 3.67E+04 O.OOE+OO 2.99E+OO 2.96E-01 1.64E-01 O.OOE+OO O.OOE+OO 8.18E+03 8.40E+04 O.OOE+OO 4.26E+04 1.13E+05 7.03E+04 O.OOE+OO 7.14E+04 9.95E+05 1.63E+04 O.OOE+OO ZN-69m 1.58E+01 2.69E+01 3.18E+OO O.OOE+OO 1.56E+01 2.72E+04 1.00E+05 O.OOE+OO ZN-69

6. 70E-02 9.66E-02 8.92E-03 O.OOE+OO 5.85E-02 1.42E+03 1.02E+04 O.OOE+OO SE-79 BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO 4.55E+03 9.62E+02 O.OOE+OO 6.33E+03 5.51 E+05 1.27E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.09E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.70E-15 O.OOE+OO O.OOE+OO O.OOE+OO 4.74E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 5.48E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.53E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+05 1.14E+05 O.OOE+OO O.OOE+OO O.OOE+OO 7.99E+03 O.OOE+OO O.OOE+OO 1.17E+05 5.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.1 OE+03 O.OOE+OO O.OOE+OO 5.62E+02 3.66E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.72E+01 O.OOE+OO O.OOE+OO 3.45E+02 2.90E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.89E+OO O.OOE+OO 5.99E+05 O.OOE+OO 1.72E+04 O.OOE+OO O.OOE+OO 2.16E+06 1.67E+05 O.OOE+OO 1.01 E+08 O.OOE+OO 6.44E+06 O.OOE+OO O.OOE+OO 1.48E+07 3.43E+05 O.OOE+OO 4.11 E+03 O.OOE+OO 1.11 E+02 O.OOE+OO O.OOE+OO 2.62E+05 2.68E+05 O.OOE+OO 1.21E+02 O.OOE+OO 4.59E+OO O.OOE+OO O.OOE+OO 5.33E+04 1.74E+05 O.OOE+OO 5.0?E-01 O.OOE+OO 1.84E-02 O.OOE+OO O.OOE+OO 2.81 E+03 1.72E+03 O.OOE+OO 9.14E+05 O.OOE+OO 2.44E+04 O.OOE+OO O.OOE+OO 2.63E+06 1.84E+05 O.OOE+OO 11.4-103 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-25 (Page 2 of 4)

Child Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 1.31 E+01 O.OOE+OO 5.25E-01 O.OOE+OO O.OOE+OO 2.40E+04 2.42E+05 O.OOE+OO 2.04E+01 O.OOE+OO 5.81 E-01 O.OOE+OO O.OOE+OO 2.39E+04 2.39E+05 O.OOE+OO 1.87E+02 O.OOE+OO 5.11 E+OO O.OOE+OO O.OOE+OO 7.44E+04 3.89E+05 O.OOE+OO NB-93m 4.70E+05 1.17E+05 3.85E+04 O.OOE+OO 1.26E+05 3.85E+05 9.07E+03 O.OOE+OO NB-95 2.35E+04 9.18E+03 6.55E+03 O.OOE+OO 8.62E+03 6.14E+05 3. 70E+04 O.OOE+OO NB-97 4.29E-01 7.70E-02 3.60E-02 O.OOE+OO 8.55E-02 3.42E+03 2.78E+04 O.OOE+OO ZR-93 7.66E+05 2.89E+05 2.05E+05 O.OOE+OO 1.11E+06 2.63E+06 5.44E+04 O.OOE+OO ZR-95 1.90E+05 4.18E+04 3. 70E+04 O.OOE+OO 5.96E+04 2.23E+06 6.11 E+04 O.OOE+OO ZR-97 1.88E+02 2.72E+01 1.60E+01 O.OOE+OO 3.89E+01 1.13E+05 3.51 E+05 O.OOE+OO M0-93 O.OOE+OO 1.39E+04 5.00E+02 O.OOE+OO 3.92E+03 6.29E+05 1.40E+04 O.OOE+OO M0-99 O.OOE+OO 1.72E+02 4.26E+01 O.OOE+OO 3.92E+02 1.35E+05 1.27E+05 O.OOE+OO TC-99 4.96E+02 5.51 E+02 1.98E+02 O.OOE+OO 6.48E+03 1.25E+06 2.87E+04 O.OOE+OO TC-99m 1.78E-03 3.48E-03 5.77E-02 O.OOE+OO 5.07E-02 9.51 E+02 4.81 E+03 O.OOE+OO TC-101 8.10E-05 8.51E-05 1.08E-03 O.OOE+OO 1.45E-03 5.85E+02 1.63E+01 O.OOE+OO RU-103 2.79E+03 O.OOE+OO 1.07E+03 O.OOE+OO 7.03E+03 6.62E+05 4.48E+04 O.OOE+OO RU-105 1.53E+OO O.OOE+OO 5.55E-01 O.OOE+OO 1.34E+OO 1.59E+04 9.95E+04 O.OOE+OO RU-106 1.36E+05 O.OOE+OO 1.69E+04 O.OOE+OO 1.84E+05 1.43E+07 4.29E+05 O.OOE+OO RH-105 1.45E+01 7.77E+OO 6.62E+OO O.OOE+OO 3.10E+01 2.89E+04 4.92E+04 O.OOE+OO PD-107 O.OOE+OO 9.81E+02 9.29E+01 O.OOE+OO 7.29E+03 1.17E+05 2.69E+03 O.OOE+OO PD-109 O.OOE+OO 5.48E+OO 1.83E+OO O.OOE+OO 2.61 E+01 2.28E+04 9.58E+04 O.OOE+OO AG-110m 1.69E+04 1.14E+04 9.14E+03 O.OOE+OO 2.12E+04 5.48E+06 1.00E+05 O.OOE+OO AG-111 6.70E+02 2.10E+02 1.39E+02 O.OOE+OO 6.33E+02 2.86E+05 1.10E+05 O.OOE+OO CD-113m O.OOE+OO 1.82E+06 7.84E+04 O.OOE+OO 1.90E+06 2.57E+06 6.03E+04 O.OOE+OO CD-115m O.OOE+OO 2.92E+05 1.25E+04 O.OOE+OO 2.19E+05 2.17E+06 1.84E+05 O.OOE+OO SN-123 4.77E+05 7.92E+03 1.55E+04 8.40E+03 O.OOE+OO 3.55E+06 1.50E+05 O.OOE+OO SN-125 1.83E+04 3.68E+02 1.09E+03 3.81E+02 O.OOE+OO 8.99E+05 2.65E+05 O.OOE+OO SN-126 2.31E+06 3.85E+04 8.73E+04 1.05E+04 O.OOE+OO 1.12E+07 6.03E+04 O.OOE+OO SB-124 5.66E+06 7.40E+02 2.00E+04 1.26E+02 O.OOE+OO 3.24E+06 1.64E+05 O.OOE+OO SB-125 9.84E+04 7.59E+02 1.99E+04 9.10E+01 O.OOE+OO 2.32E+06 4.03E+04 O.OOE+OO SB-126 6.36E+03 9.69E+01 2.28E+03 3.70E+01 O.OOE+OO 1.06E+06 2.10E+05 O.OOE+OO SB-127 5.03E+02 7.73E+OO 1.74E+02 5.59E+OO O.OOE+OO 2.28E+05 1.41E+05 O.OOE+OO TE-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 O.OOE+OO 4.77E+05 3.38E+04 O.OOE+OO TE-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 O.OOE+OO TE-127 2.77E+OO 9.51E-01 6.11E-01 1.96E+OO 7.07E+OO 1.00E+04 5.62E+04 O.OOE+OO TE-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1. 76E+06 1.82E+05 O.OOE+OO TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 O.OOE+OO TE-133m 1.08E-01 5.59E-02 5.55E-02 8.58E-02 3.74E-01 5.92E+03 1.76E+04 O.OOE+OO 11.4-104 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-25 (Page 3 of 4)

Child Inhalation P1 mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 5.66E-02 3.26E-02 3.48E-02 4.59E-02 2.11 E-01 4.55E+03 1.80E+03 O.OOE+OO 3.89E+04 2.37E+04 2.11 E+04 1.58E+07 4.00E+04 O.OOE+OO 7.96E+02 O.OOE+OO 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 O.OOE+OO 5.11 E+03 O.OOE+OO 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 O.OOE+OO 2.84E+03 O.OOE+OO TE-131 m 1.34E+02 5.92E+01 5.07E+01 9. 77E+01 4.00E+02 2.06E+05 3.08E+05 O.OOE+OO TE-131 2.17E-02 8.44E-03 6.59E-03 1.70E-02 5.88E-02 2.05E+03 1.33E+03 O.OOE+OO 1-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+OO 3.20E+03 O.OOE+OO TE-132 4.81E+02 2.72E+02 2.63E+02 3.18E+02 1.77E+03 3.77E+05 1.38E+05 O.OOE+OO 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 O.OOE+OO 5.48E+03 O.OOE+OO CS-134m 2.34E+02 3.30E+02 2.26E+02 O.OOE+OO 1.83E+02 3.09E+01 2.93E+02 O.OOE+OO CS-134 6.51E+05 1.01E+06 2.25E+05 O.OOE+OO 3.30E+05 1.21E+05 3.85E+03 O.OOE+OO 1-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 O.OOE+OO 9.55E+02 O.OOE+OO 1-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 O.OOE+OO 4.44E+03 O.OOE+OO CS-135 2.31 E+05 1.53E+05 1.65E+04 O.OOE+OO 5.66E+04 1.93E+04 8.03E+02 O.OOE+OO CS-136 6.51E+04 1.71E+05 1.16E+05 O.OOE+OO 9.55E+04 1.45E+04 4.18E+03 O.OOE+OO CS-137 9.07E+05 8.25E+05 1.28E+05 O.OOE+OO 2.82E+05 1.04E+05 3.62E+03 O.OOE+OO CS-138 6.33E+02 8.40E+02 5.55E+02 O.OOE+OO 6.22E+02 6.81 E+01 2. 70E+02 O.OOE+OO CS-139 4.03E+02 4.26E+02 2.15E+02 O.OOE+OO 3.36E+02 3.46E+01 2.68E-02 O.OOE+OO BA-139 1.84E+OO 9.84E-04 5.37E-02 O.OOE+OO 8.62E-04 5.77E+03 5.77E+04 O.OOE+OO BA-140 7.40E+04 6.48E+01 4.33E+03 O.OOE+OO 2.11 E+01 1. 74E+06 1.02E+05 O.OOE+OO LA-140 6.44E+02 2.25E+02 7.55E+01 O.OOE+OO O.OOE+OO 1.83E+05 2.26E+05 O.OOE+OO BA-141 1.96E-01 1.09E-04 6.36E-03 O.OOE+OO 9.47E-05 2.92E+03 2.75E+02 O.OOE+OO LA-141 8.47E+OO 1.96E+OO 4.26E-01 O.OOE+OO O.OOE+OO 1.66E+04 1.62E+05 O.OOE+OO CE-141 3.92E+04 1.95E+04 2.90E+03 O.OOE+OO 8.55E+03 5.44E+05 5.66E+04 O.OOE+OO BA-142 5.00E-02 3.60E-05 2.79E-03 O.OOE+OO 2.91 E-05 1.64E+03 2.74E+OO O.OOE+OO LA-142 1.30E+OO 4.11E-01 1.29E-01 O.OOE+OO O.OOE+OO 8.70E+03 7.59E+04 O.OOE+OO CE-143 3.66E+02 1.99E+02 2.88E+01 O.OOE+OO 8.36E+01 1.15E+05 1.27E+05 O.OOE+OO PR-143 1.85E+04 5.55E+03 9.14E+02 O.OOE+OO 3.00E+03 4.33E+05 9.73E+04 O.OOE+OO CE-144 6.77E+06 2.12E+06 3.62E+05 O.OOE+OO 1.17E+06 1.20E+07 3.89E+05 O.OOE+OO PR-144 5.96E-02 1.85E-02 3.00E-03 O.OOE+OO 9.77E-03 1.57E+03 1.97E+02 O.OOE+OO ND-147 1.08E+04 8.73E+03 6.81E+02 O.OOE+OO 4.81E+03 3.28E+05 8.21E+04 O.OOE+OO PM-147 1.30E+06 9.32E+04 5.03E+04 O.OOE+OO 1.65E+05 8.14E+05 2.11 E+04 O.OOE+OO PM-148m 1.22E+05 2.42E+04 2.42E+04 O.OOE+OO 3.60E+04 2.12E+06 1.32E+05 O.OOE+OO PM-148 5.96E+03 7.18E+02 4.63E+02 O.OOE+OO 1.22E+03 4.59E+05 2.22E+05 O.OOE+OO PM-149 5.44E+02 5.77E+01 3.13E+01 O.OOE+OO 1.02E+02 8.88E+04 1.08E+05 O.OOE+OO PM-151 1.32E+02 1.60E+01 1.04E+01 O.OOE+OO 2.72E+01 4.59E+04 9.55E+04 O.OOE+OO SM-151 1.16E+06 1.76E+05 5.51E+04 O.OOE+OO 1.81E+05 5.48E+05 1.27E+04 O.OOE+OO 11.4-105 LASALLE ODCM PART II SECTION 4.doc

Table 4-25 (Page 4 of 4)

Child Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LU Skin SM-153 2.68E+02 1.67E+02 1.61 E+01 O.OOE+OO 5.07E+01 5.07E+04 6.92E+04 O.OOE+OO EU-152 2.75E+06 5.07E+05 5.96E+05 O.OOE+OO 2.12E+06 3.33E+06 4.22E+04 O.OOE+OO EU-154 1.01 E+07 9.21 E+05 8.40E+05 O.OOE+OO 4.03E+06 6.14E+06 1.1 OE+05 O.OOE+OO EU-155 2.07E+06 1.50E+05 1.18E+05 O.OOE+OO 5.59E+05 1.03E+06 1.99E+05 O.OOE+OO EU-156 2.92E+04 1.57E+04 3.24E+03 O.OOE+OO 1.01 E+04 9.40E+05 1.57E+05 O.OOE+OO TB-160 2.88E+05 O.OOE+OO 3.58E+04 O.OOE+OO 8.58E+04 1.98E+06 8.44E+04 O.OOE+OO H0-166m 4.96E+06 1.04E+06 8.77E+05 O.OOE+OO 1.48E+06 4.18E+06 6.03E+04 O.OOE+OO W-181 9.84E+01 2.41E+01 3.33E+OO O.OOE+OO O.OOE+OO 2.11E+04 9.66E+02 O.OOE+OO W-185 3.07E+03 7.70E+02 1.08E+02 O.OOE+OO O.OOE+OO 6.88E+05 4.11E+04 O.OOE+OO W-187 1.63E+01 9.66E+OO 4.33E+OO O.OOE+OO O.OOE+OO 4.11 E+04 9.10E+04 O.OOE+OO NP-239 4.66E+02 3.35E+01 2.35E+01 O.OOE+OO 9.73E+01 5.81 E+04 6.40E+04 O.OOE+OO U-232 8.10E+08 O.OOE+OO 5. 77E+07 O.OOE+OO 6.18E+07 2. 75E+09 1.60E+05 O.OOE+OO U-233 1.72E+08 O.OOE+OO 1.04E+07 O.OOE+OO 2.82E+07 6.55E+08 1.48E+05 O.OOE+OO U-234 1.65E+08 O.OOE+OO 1.02E+07 O.OOE+OO 2. 76E+07 6.44E+08 1.45E+05 O.OOE+OO U-235 1.58E+08 O.OOE+OO 9.58E+06 O.OOE+OO 2.59E+07 6.03E+08 1.84E+05 O.OOE+OO U-236 1.58E+08 O.OOE+OO 9.81 E+06 O.OOE+OO 2.65E+07 6.18E+08 1.36E+05 O.OOE+OO U-237 5.81E+02 O.OOE+OO 1.54E+02 O.OOE+OO 1.68E+03 1.26E+05 4.77E+04 O.OOE+OO U-238 1.51 E+08 O.OOE+OO 8.95E+06 O.OOE+OO 2.42E+07 5.66E+08 1.30E+05 O.OOE+OO NP-237 1.01 E+10 5.99E+09 4.40E+08 O.OOE+OO 2.74E+09 6.44E+08 1.87E+05 O.OOE+OO NP-238 4.66E+03 8.51 E+02 7.29E+01 O.OOE+OO 3.02E+02 1.25E+05 9.25E+04 O.OOE+OO PU-238 9.44E+09 5.92E+09 4.48E+08 O.OOE+OO 1.65E+09 2.25E+09 1. 72E+05 O.OOE+OO PU-239 1.03E+10 6.22E+09 4.74E+08 O.OOE+OO 1.77E+09 2.12E+09 1.57E+05 O.OOE+OO PU-240 1.03E+10 6.22E+09 4. 70E+08 O.OOE+OO 1. 76E+09 2.11 E+09 1.60E+05 O.OOE+OO PU-241 2.94E+08 6.48E+07 1.08E+07 O.OOE+OO 4.07E+07 1.87E+06 3.29E+03 O.OOE+OO PU-242 9.58E+09 5.99E+09 4.55E+08 O.OOE+OO 1.70E+09 2.04E+09 1.54E+05 O.OOE+OO PU-244 1.12E+10 6.85E+09 5.22E+08 O.OOE+OO 1.95E+09 2.33E+09 2.29E+05 O.OOE+OO AM-241 1.10E+10 6.81E+09 4.59E+08 O.OOE+OO 2.82E+09 7.47E+08 1.75E+05 O.OOE+OO AM-242m 1.14E+10 6.51 E+09 4.70E+08 O.OOE+OO 2.85E+09 3.01 E+08 2.21 E+05 O.OOE+OO AM-243 1.09E+10 6.59E+09 4.44E+08 O.OOE+OO 2.75E+09 7.10E+08 2.05E+05 O.OOE+OO CM-242 3.51E+08 2.10E+08 1.55E+07 O.OOE+OO 4.96E+07 4.85E+08 1.87E+05 O.OOE+OO CM-243 8.58E+09 5.25E+09 3.68E+08 O.OOE+OO 1.38E+09 7.77E+08 1.84E+05 O.OOE+OO CM-244 7.18E+09 4.37E+09 3.07E+08 O.OOE+OO 1.13E+09 7.47E+08 1.78E+05 O.OOE+OO CM-245 1.13E+10 6.81E+09 4.74E+08 O.OOE+OO 1.86E+09 7.22E+08 1.66E+05 O.OOE+OO CM-246 1.12E+10 6.81 E+09 4.74E+08 O.OOE+OO 1.86E+09 7.36E+08 1.63E+05 O.OOE+OO CM-247 1.09E+10 6.73E+09 4.66E+08 O.OOE+OO 1.83E+09 7.22E+08 2.15E+05 O.OOE+OO CM-248 9.07E+10 5.55E+10 3.85E+09 O.OOE+OO 1.51E+10 5.96E+09 3.46E+06 O.OOE+OO CF-252 8.07E+09 O.OOE+OO 3.45E+08 O.OOE+OO O.OOE+OO 2.45E+09 6.81 E+05 O.OOE+OO 11.4-106 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table4-26(Page1 of4)

Teen Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin O.OOE+OO 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 O.OOE+OO 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 O.OOE+OO 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 O.OOE+OO 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 O.OOE+OO 1.89E+06 1.10E+05 7.16E+04 O.OOE+OO O.OOE+OO O.OOE+OO 9.28E+04 O.OOE+OO 3.24E+05 O.OOE+OO 3.50E+04 O.OOE+OO 1.08E+06 8.08E+08 2.38E+05 O.OOE+OO 5.79E+05 1.13E+06 3.34E+05 7.50E+01 3.07E+01 2.10E+04 3.00E+03 O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+02 7.50E+01 3.07E+01 2.10E+04 3.00E+03 O.OOE+OO O.OOE+OO 5.11 E+04 8.40E+03 O.OOE+OO 1.27E+04 1.98E+06 6.68E+04 O.OOE+OO 3.34E+04 2.38E+04 5.54E+03 O.OOE+OO O.OOE+OO 1.24E+05 6.39E+03 O.OOE+OO O.OOE+OO 1.70E+OO 2.52E-01 O.OOE+OO 1.79E+OO 1.52E+04 5.74E+04 O.OOE+OO O.OOE+OO 9.44E+02 9.20E+02 O.OOE+OO O.OOE+OO 5.86E+05 3.14E+04 O.OOE+OO O.OOE+OO 2.07E+03 2.78E+03 O.OOE+OO O.OOE+OO 1.34E+06 9.52E+04 O.OOE+OO 1.59E+04 3. 70E+04 1.43E+04 O.OOE+OO O.OOE+OO 1.53E+06 1. 78E+05 O.OOE+OO O.OOE+OO 1.51E+04 1.98E+04 O.OOE+OO O.OOE+OO 8.72E+06 2.59E+05 O.OOE+OO 4.35E+04 1.62E+04 7.39E+03 O.OOE+OO O.OOE+OO 1.13E+05 5.18E+03 O.OOE+OO 5.80E+05 4.34E+04 1.98E+04 O.OOE+OO O.OOE+OO 3.07E+05 1.42E+04 O.OOE+OO O.OOE+OO 2.03E+OO 8.48E-01 O.OOE+OO 6.41E+OO 1.11E+04 6.14E+04 O.OOE+OO 2.18E+OO 2.93E-01 1.27E-01 O.OOE+OO O.OOE+OO 9.36E+03 3.67E+04 O.OOE+OO 3.86E+04 1.34E+05 6.24E+04 O.OOE+OO 8.64E+04 1.24E+06 4.66E+04 O.OOE+OO ZN-69m 1.15E+01 2.47E+01 2.49E+OO O.OOE+OO 1.65E+01 3.14E+04 1. 71 E+OS O.OOE+OO ZN-69 4.83E-02 9.20E-02 6.46E-03 O.OOE+OO 6.02E-02 1.58E+03 2.85E+02 O.OOE+OO SE-79 O.OOE+OO 4.34E+03 6.97E+02 O.OOE+OO 6.50E+03 6.17E+05 2.82E+04 O.OOE+OO BR-82 O.OOE+OO O.OOE+OO 1.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.00E-15 O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 3.44E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO O.OOE+OO 4.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.83E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.40E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1. 77E+04 O.OOE+OO O.OOE+OO 1.12E+05 3.66E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.44E+03 O.OOE+OO O.OOE+OO 5.46E+02 2.72E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.92E-05 O.OOE+OO O.OOE+OO 3.52E+02 2.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.38E-07 O.OOE+OO 4.34E+05 O.OOE+OO 1.25E+04 O.OOE+OO O.OOE+OO 2.42E+06 3.71 E+05 O.OOE+OO 1.08E+08 O.OOE+OO 6.68E+06 O.OOE+OO O.OOE+OO 1.65E+07 7.65E+05 O.OOE+OO 2.98E+03 O.OOE+OO 8.00E+01 O.OOE+OO O.OOE+OO 2.93E+05 5.59E+05 O.OOE+OO 8.80E+01 O.OOE+OO 3.51 E+OO O.OOE+OO O.OOE+OO 6.07E+04 2.59E+05 O.OOE+OO

3. 70E-01 O.OOE+OO 1.42E-02 O.OOE+OO O.OOE+OO 3.20E+03 3.02E+01 O.OOE+OO 6.61E+05 O.OOE+OO 1.77E+04 O.OOE+OO O.OOE+OO 2.94E+06 4.09E+05 O.OOE+OO 11.4-107 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-26 (Page 2 of 4)

Teen Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 9.52E+OO O.OOE+OO 4.06E-01 O.OOE+OO O.OOE+OO 2.74E+04 1.19E+05 O.OOE+OO 1.47E+01 O.OOE+OO 4.29E-01 O.OOE+OO O.OOE+OO 2.68E+04 1.65E+05 O.OOE+OO 1.35E+02 O.OOE+OO 3.72E+OO O.OOE+OO O.OOE+OO 8.32E+04 5.79E+05 O.OOE+OO NB-93m 3.31E+05 1.09E+05 2.73E+04 O.OOE+OO 1.27E+05 4.29E+05 2.02E+04 O.OOE+OO NB-95 1.86E+04 1.03E+04 5.66E+03 O.OOE+OO 1.00E+04 7.51 E+05 9.68E+04 O.OOE+OO NB-97 3.14E-01 7.78E-02 2.84E-02 O.OOE+OO 9.12E-02 3.93E+03 2.17E+03 O.OOE+OO ZR-93 5.46E+05 2.70E+05 1.47E+05 O.OOE+OO 9.28E+05 2.94E+06 1.28E+05 O.OOE+OO ZR-95 1.46E+05 4.58E+04 3.15E+04 O.OOE+OO 6. 74E+04 2.69E+06 1.49E+05 O.OOE+OO ZR-97 1.38E+02 2. 72E+01 1.26E+01 O.OOE+OO 4.12E+01 1.30E+05 6.30E+05 O.OOE+OO M0-93 O.OOE+OO 1.33E+04 3.62E+02 O.OOE+OO 4.05E+03 7.05E+05 3.19E+04 O.OOE+OO M0-99 O.OOE+OO 1.69E+02 3.22E+01 O.OOE+OO 4.11 E+02 1.54E+05 2.69E+05 O.OOE+OO TC-99 3.58E+02 5.26E+02 1.43E+02 O.OOE+OO 6.68E+03 1.39E+06 6.39E+04 O.OOE+OO TC-99m 1.38E-03 3.86E-03 4.99E-02 O.OOE+OO 5.76E-02 1.15E+03 6.13E+03 O.OOE+OO TC-101 5.92E-05 8.40E-05 8.24E-04 O.OOE+OO 1.52E-03 6.67E+02 8.72E-07 O.OOE+OO RU-103 2.10E+03 O.OOE+OO 8.96E+02 O.OOE+OO 7.43E+03 7.83E+05 1.09E+05 O.OOE+OO RU-105 1.12E+OO O.OOE+OO 4.34E-01 O.OOE+OO 1.41E+OO 1.82E+04 9.04E+04 O.OOE+OO RU-106 9.84E+04 O.OOE+OO 1.24E+04 O.OOE+OO 1.90E+05 1.61E+07 9.60E+05 O.OOE+OO RH-105 1.06E+01 7.58E+OO 4.99E+OO O.OOE+OO 3.23E+01 3.27E+04 9.84E+04 O.OOE+OO PD-107 O.OOE+OO 9.36E+02 6.71E+01 O.OOE+OO 7.51E+03 1.30E+05 5.99E+03 O.OOE+OO PD-109 O.OOE+OO 5.25E+OO 1.33E+OO O.OOE+OO 2.69E+01 2.55E+04 1.57E+05 O.OOE+OO AG-110m 1.38E+04 1.31E+04 7.99E+03 O.OOE+OO 2.50E+04 6.75E+06 2.73E+05 O.OOE+OO AG-111 4.86E+02 2.02E+02 1.02E+02 O.OOE+OO 6.54E+02 3.20E+05 2.40E+05 O.OOE+OO CD-113m O.OOE+OO 1.74E+06 5.68E+04 O.OOE+OO 1.94E+06 2.87E+06 1.34E+05 O.OOE+OO CD-115m O.OOE+OO 2.78E+05 9.12E+03 O.OOE+OO 2.26E+05 2.42E+06 4.08E+05 O.OOE+OO SN-123 3.45E+05 7.55E+03 1.12E+04 6.04E+03 O.OOE+OO 3.97E+05 3.33E+05 O.OOE+OO SN-125 1.33E+04 3.54E+02 7.99E+02 2.76E+02 O.OOE+OO 1.01 E+06 5.83E+05 O.OOE+OO SN-126 1.74E+06 4.31E+04 6.59E+04 1.14E+04 O.OOE+OO 1.38E+07 1.34E+05 O.OOE+OO SB-124 4.30E+04 7.94E+02 1.68E+04 9.76E+01 O.OOE+OO 3.85E+06 3.98E+05 O.OOE+OO SB-125 7.38E+04 8.08E+02 1.72E+04 7.04E+01 O.OOE+OO 2.74E+06 9.92E+04 O.OOE+OO SB-126 4.95E+03 1.02E+02 1.78E+03 2.80E+01 O.OOE+OO 1.24E+06 4.81E+05 O.OOE+OO SB-127 3.71E+02 7.94E+OO 1.40E+02 4.17E+OO O.OOE+OO 2.65E+05 3.15E+05 O.OOE+OO TE-125m 4.88E+03 2.24E+03 6.67E+02 1.40E+03 O.OOE+OO 5.36E+05 7.50E+04 O.OOE+OO TE-127m 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 O.OOE+OO TE-127 2.01 E+OO 9.12E-01 4.42E-01 1.42E+OO 7.28E+OO 1.12E+04 8.08E+04 O.OOE+OO TE-129m 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 O.OOE+OO TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 O.OOE+OO TE-133m 8.08E-02 5.86E-02 4.57E-02 6.54E-02 2.46E-01 6.97E+03 9.84E+02 O.OOE+OO 11.4-108 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-26 (Page 3 of 4)

Teen Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 4.25E-02 3.48E-02 2.91 E-02 3.57E-02 2.33E-01 5.38E+03 1.1 OE+01 O.OOE+OO 2.82E+04 2.35E+04 7.12E+04 2.93E+07 4.21E+04 O.OOE+OO 1.83E+03 O.OOE+OO 6.24E+03 1. 79E+04 7.17E+03 1.49E+06 2. 75E+04 O.OOE+OO 9.12E+03 O.OOE+OO 3.54E+04 4.91 E+04 2.64E+04 1.46E+07 8.40E+04 O.OOE+OO 6.49E+03 O.OOE+OO TE-131 m 9.84E+01 6.01 E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21 E+05 O.OOE+OO TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 O.OOE+OO 1-132 1.59E+03 4.38E+03 1.58E+03 1.51E+05 6.92E+03 O.OOE+OO 1.27E+03 O.OOE+OO TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 O.OOE+OO 1-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 O.OOE+OO 1.03E+04 O.OOE+OO CS-134m 1.76E+02 3.48E+02 1.88E+02 O.OOE+OO 2.03E+02 3.65E+01 1.62E+02 O.OOE+OO CS-134 5.02E+05 1.13E+06 5.49E+05 O.OOE+OO 3.75E+05 1.46E+05 9.76E+03 O.OOE+OO 1-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 O.OOE+OO 2.04E+01 O.OOE+OO 1-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 O.OOE+OO 6.95E+03 O.OOE+OO CS-135 1.66E+05 1.46E+05 3.58E+04 O.OOE+OO 5.84E+04 2.16E+04 1.78E+03 O.OOE+OO CS-136 5.15E+04 1.94E+05 1.37E+05 O.OOE+OO 1.10E+05 1.78E+04 1.09E+04 O.OOE+OO CS-137 6.70E+05 8.48E+05 3.11E+05 O.OOE+OO 3.04E+05 1.21E+05 8.48E+03 O.OOE+OO CS-138 4.66E+02 8.56E+02 4.46E+02 O.OOE+OO 6.62E+02 7.87E+01

2. 70E-01 O.OOE+OO CS-139 2.92E+02 4.10E+02 1.58E+02 O.OOE+OO 3.47E+02 3.89E+01 1.33E-13 O.OOE+OO BA-139 1.34E+OO 9.44E-04 3.90E-02 O.OOE+OO 8.88E-04 6.46E+03 6.45E+03 O.OOE+OO BA-140 5.47E+04 6.70E+01 3.52E+03 O.OOE+OO 2.28E+01 2.03E+06 2.29E+05 O.OOE+OO LA-140 4.79E+02 2.36E+02 6.26E+01 O.OOE+OO O.OOE+OO 2.14E+05 4.87E+05 O.OOE+OO BA-141 1.42E-01 1.06E-04 4.74E-03 O.OOE+OO 9.84E-05 3.29E+03 7.46E-04 O.OOE+OO LA-141 6.10E+OO 1.88E+OO 3.10E-01 O.OOE+OO O.OOE+OO 1.85E+04 1.23E+05 O.OOE+OO CE-141 2.84E+04 1.90E+04 2.17E+03 O.OOE+OO 8.88E+03 6.14E+05 1.26E+05 O.OOE+OO BA-142 3.70E-02 3.70E-05 2.27E-03 O.OOE+OO 3.14E-05 1.91E+03 4.79E-10 O.OOE+OO LA-142 9.60E-01 4.25E-01 1.06E-01 O.OOE+OO O.OOE+OO 1.02E+04 1.20E+04 O.OOE+OO CE-143 2.66E+02 1.94E+02 2.16E+01 O.OOE+OO 8.64E+01 1.30E+05 2.55E+05 O.OOE+OO PR-143 1.34E+04 5.31E+03 6.62E+02 O.OOE+OO 3.09E+03 4.83E+05 2.14E+05 O.OOE+OO CE-144 4.89E+06 2.02E+06 2.62E+05 O.OOE+OO 1.21E+06 1.34E+07 8.64E+05 O.OOE+OO PR-144 4.30E-02 1.76E-02 2.18E-03 O.OOE+OO 1.01E-02 1.75E+03 2.35E-04 O.OOE+OO ND-147 7.86E+03 8.56E+03 5.13E+02 O.OOE+OO 5.02E+03 3.72E+05 1.82E+05 O.OOE+OO PM-147 9.20E+05 8.80E+04 3.60E+04 O.OOE+OO 1.68E+05 9.12E+05 4. 70E+04 O.OOE+OO PM-148m 1.06E+05 2.68E+04 2.10E+04 O.OOE+OO 4.06E+04 2.56E+06 3.28E+05 O.OOE+OO PM-148 4.35E+03 7.1 OE+02 3.58E+02 O.OOE+OO 1.28E+03 5.22E+05 4.91 E+05 O.OOE+OO PM-149 3.93E+02 5.51 E+01 2.27E+01 O.OOE+OO 1.05E+02 9.92E+04 2.23E+05 O.OOE+OO PM-151 9.60E+01 1.59E+01 8.08E+OO O.OOE+OO 2.86E+01 4.52E+04 1.82E+05 O.OOE+OO SM-151 8.56E+05 1.68E+05 3.89E+04 O.OOE+OO 1.82E+05 6.14E+05 2.82E+04 O.OOE+OO 11.4-109 LASALLE ODCM PART II SECTION 4.doc

Table 4-26 (Page 4 of 4)

Teen Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LU Skin SM-153 1.94E+02 1.61E+02 1.18E+01 O.OOE+OO 5.25E+01 5.69E+04 1.42E+05 O.OOE+OO EU-152 2.37E+06 5. 75E+05 5.04E+05 O.OOE+OO 2.67E+06 4.01 E+06 1.08E+05 O.OOE+OO EU-154 7.54E+06 9.84E+05 6.88E+05 O.OOE+OO 4.35E+06 7.30E+06 2.67E+05 O.OOE+OO EU-155 1.60E+06 1.57E+05 9.68E+04 O.OOE+OO 6.12E+05 1.21E+07 4.78E+05 O.OOE+OO EU-156 2.16E+04 1.62E+04 2.64E+03 O.OOE+OO 1.09E+04 1.1 OE+06 3.65E+05 O.OOE+OO TB-160 2.43E+05 O.OOE+OO 3.03E+04 O.OOE+OO 9.60E+04 3.18E+06 2.08E+05 O.OOE+OO H0-166m 3.52E+06 1.25E+06 7.90E+05 O.OOE+OO 1.60E+06 4.99E+06 1.34E+05 O.OOE+OO W-181 7.12E+01 2.30E+01 2.41E+OO O.OOE+OO O.OOE+OO 2.36E+04 2.15E+03 O.OOE+OO W-185 2.22E+03 7.34E+02 7.78E+01 O.OOE+OO O.OOE+OO 7.68E+05 9.12E+04 O.OOE+OO W-187 1.20E+01 9.76E+OO 3.43E+OO O.OOE+OO O.OOE+OO 4.74E+04 1.77E+05 O.OOE+OO NP-239 3.38E+02 3.19E+01 1. 77E+01 O.OOE+OO 1.00E+02 6.49E+04 1.32E+05 O.OOE+OO U-232 5.85E+08 O.OOE+OO 4.18E+07 O.OOE+OO 6.35E+07 3.07E+09 3.57E+05 O.OOE+OO U-233 1.24E+08 O.OOE+OO 7.54E+06 O.OOE+OO 2.90E+07 7.34E+08 3.30E+05 O.OOE+OO U-234 1.18E+08 O.OOE+OO 7.38E+06 O.OOE+OO 2.84E+07 7.19E+08 3.23E+05 O.OOE+OO U-235 1.14E+08 O.OOE+OO 6.94E+06 O.OOE+OO 2.67E+07 6.75E+08 4.10E+05 O.OOE+OO U-236 1.14E+08 O.OOE+OO 7.09E+06 O.OOE+OO 2. 73E+07 6.90E+08 3.03E+05 O.OOE+OO U-237 4.20E+02 O.OOE+OO 1.12E+02 O.OOE+OO 1.73E+03 1.41E+05 1.03E+05 O.OOE+OO U-238 1.09E+08 O.OOE+OO 6.48E+06 O.OOE+OO 2.50E+07 6.31 E+08 2.90E+05 O.OOE+OO NP-237 1.31E+10 8.48E+09 5.77E+08 O.OOE+OO 4.28E+09 7.19E+08 4.18E+05 O.OOE+OO NP-238 3.38E+03 8.16E+02 5.27E+01 O.OOE+OO 3.10E+02 1.40E+05 1.90E+05 O.OOE+OO PU-238 1.20E+10 8.24E+09 5.78E+08 O.OOE+OO 2.48E+09 2.50E+09 3.83E+05 O.OOE+OO PU-239 1.38E+10 8.96E+09 6.44E+08 O.OOE+OO 2.75E+09 2.34E+09 3.50E+05 O.OOE+OO PU-240 1.38E+10 8.96E+09 6.43E+08 O.OOE+OO 2.74E+09 2.34E+09 3.57E+05 O.OOE+OO PU-241 2.99E+08 7.65E+07 1.12E+07 O.OOE+OO 5.18E+07 2.08E+06 7.34E+03 O.OOE+OO PU-242 1.28E+10 8.64E+09 6.20E+08 O.OOE+OO 2.65E+09 2.26E+09 3.43E+05 O.OOE+OO PU-244 1.50E+10 9.92E+09 7.10E+08 O.OOE+OO 3.03E+09 2.58E+09 5.11 E+05 O.OOE+OO AM-241 1.42E+10 9.60E+09 5.68E+08 O.OOE+OO 4.26E+09 8.40E+08 3.90E+05 O.OOE+OO AM-242m 1.43E+10 9.04E+09 5.72E+08 O.OOE+OO 4.24E+09 3.37E+08 4.91E+05 O.OOE+OO AM-243 1.42E+10 9.36E+09 5.56E+08 O.OOE+OO 4.17E+09 7.93E+08 4.58E+05 O.OOE+OO CM-242 2.54E+08 2.01 E+08 1.13E+07 O.OOE+OO 5.12E+07 5.41 E+08 4.17E+05 O.OOE+OO CM-243 9.52E+09 6.64E+09 4.00E+08 O.OOE+OO 1.87E+09 8. 72E+08 4.1 OE+05 O.OOE+OO CM-244 7.35E+09 5.22E+09 3.10E+08 O.OOE+OO 1.45E+09 8.40E+08 3.97E+05 O.OOE+OO CM-245 1.46E+10 9.76E+09 6.02E+08 O.OOE+OO 2.82E+09 8.08E+08 3.70E+05 O.OOE+OO CM-246 1.45E+10 9.76E+09 6.02E+08 O.OOE+OO 2.81E+09 8.24E+08 3.63E+05 O.OOE+OO CM-247 1.42E+10 9.52E+09 5.93E+08 O.OOE+OO 2.77E+09 8.08E+08 4.78E+05 O.OOE+OO CM-248 1.18E+11 7.86E+10 4.89E+09 O.OOE+OO 2.28E+10 6.66E+09 7.70E+06 O.OOE+OO CF-252 5.73E+09 O.OOE+OO 2.46E+08 O.OOE+OO O.OOE+OO 2.74E+09 1.51E+06 O.OOE+OO 11.4-110 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-27 (Page 1 of 4)

Adult Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 1.26E+03 O.OOE+OO 1.82E+04 3.41 E+03 3.41 E+03 3.41 E+03 3.41 E+03 3.41 E+03 3.41 E+03 O.OOE+OO 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 1.04E+05 O.OOE+OO 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 1.02E+04 O.OOE+OO 1.32E+06 7.71E+04 5.01E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.64E+04 O.OOE+OO 3.06E+05 O.OOE+OO 3.30E+04 O.OOE+OO O.OOE+OO 3.06E+04 2.29E+03 O.OOE+OO 4.41E+05 8.56E+05 2.49E+05 O.OOE+OO 7.99E+05 O.OOE+OO 2.58E+05 O.OOE+OO O.OOE+OO O.OOE+OO 1.00E+02 5.95E+01 2.28E+01 1.44E+04 3.32E+03 O.OOE+OO O.OOE+OO 3.96E+04 6.30E+03 O.OOE+OO 9.84E+03 1.40E+06 7.74E+04 O.OOE+OO 2.46E+04 1.70E+04 3.94E+03 O.OOE+OO O.OOE+OO 7.21E+04 6.03E+03 O.OOE+OO O.OOE+OO 1.24E+OO 1.83E-01 O.OOE+OO 1.30E+OO 9.44E+03 2.02E+04 O.OOE+OO O.OOE+OO 6.92E+02 6.71E+02 O.OOE+OO O.OOE+OO 3.70E+05 3.14E+04 O.OOE+OO O.OOE+OO 1.58E+03 2.07E+03 O.OOE+OO O.OOE+OO 9.28E+05 1.06E+05 O.OOE+OO 1.18E+04 2. 78E+04 1.06E+04 O.OOE+OO O.OOE+OO 1.02E+06 1.88E+05 O.OOE+OO O.OOE+OO 1.15E+04 1.48E+04 O.OOE+OO O.OOE+OO 5.97E+06 2.85E+05 O.OOE+OO 3.25E+04 1.17E+04 5.42E+03 O.OOE+OO O.OOE+OO 6.56E+04 4.89E+03 O.OOE+OO 4.32E+05 3.14E+04 1.45E+04 O.OOE+OO O.OOE+OO 1. 78E+05 1.34E+04 O.OOE+OO O.OOE+OO 1.46E+OO 6.15E-01 O.OOE+OO 4.62E+OO 6.78E+03 4.90E+04 O.OOE+OO 1.54E+OO 2.10E-01 9.12E-02 O.OOE+OO O.OOE+OO 5.60E+03 1.23E+04 O.OOE+OO 3.24E+04 1.03E+05 4.66E+04 O.OOE+OO 6.90E+04 8.64E+05 5.34E+04 O.OOE+OO ZN-69m 8.16E+OO 1.96E+01

1. 79E+OO O.OOE+OO 1.18E+01 1.90E+04 1.37E+05 O.OOE+OO ZN-69 3.38E-02 6.51 E-02 4.52E-03 O.OOE+OO 4.22E-02 9.20E+02 1.63E+01 O.OOE+OO SE-79 BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO 3.06E+03 4.87E+02 O.OOE+OO 4.55E+03 3.58E+05 2.66E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.04E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.41 E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.32E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.13E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.64E-03 O.OOE+OO O.OOE+OO O.OOE+OO 1.28E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+05 5.90E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.66E+04 O.OOE+OO O.OOE+OO 3.87E+02 2.57E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.30E+03 O.OOE+OO O.OOE+OO 3.87E+02 1.93E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.34E-09 O.OOE+OO O.OOE+OO 2.56E+02 1.70E+02 O.OOE+OO O.OOE+OO O.OOE+OO 9.28E-12 O.OOE+OO 3.04E+05 O.OOE+OO 8.72E+03 O.OOE+OO O.OOE+OO 1.40E+06 3.50E+05 O.OOE+OO 9.92E+07 O.OOE+OO 6.10E+06 O.OOE+OO O.OOE+OO 9.60E+06 7.22E+05 O.OOE+OO 2.09E+03 O.OOE+OO 5.61 E+01 O.OOE+OO O.OOE+OO 1. 70E+05 5.06E+05 O.OOE+OO 6.19E+01 O.OOE+OO 2.50E+OO O.OOE+OO O.OOE+OO 3.65E+04 1.91 E+05 O.OOE+OO 2.61 E-01 O.OOE+OO 1.02E-02 O.OOE+OO O.OOE+OO 1.92E+03 1.33E+OO O.OOE+OO 4.62E+05 O.OOE+OO 1.24E+04 O.OOE+OO O.OOE+OO 1. 70E+06 3.85E+05 O.OOE+OO 11.4-111 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-27 (Page 2 of 4)

Adult Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin

6. 7 4E+OO O.OOE+OO 2.91 E-01 O.OOE+OO O.OOE+OO 1.65E+04 4.30E+04 O.OOE+OO 1.03E+01 O.OOE+OO 3.02E-01 O.OOE+OO O.OOE+OO 1.57E+04 7.35E+04 O.OOE+OO 9.44E+01 O.OOE+OO 2.61 E+OO O.OOE+OO O.OOE+OO 4.85E+04 4.22E+05 O.OOE+OO NB-93m 2.48E+05 8.08E+04 1.99E+04 O.OOE+OO 9.28E+04 2.49E+05 1.90E+04 O.OOE+OO NB-95 1.41E+04 7.82E+03 4.21E+03 O.OOE+OO 7.74E+03 5.05E+05 1.04E+05 O.OOE+OO NB-97 2.22E-01 5.62E-02 2.05E-02 O.OOE+OO 6.54E-02 2.40E+03 2.42E+02 O.OOE+OO ZR-93 4.18E+05 2.34E+04 1.10E+04 O.OOE+OO 8.88E+04 1.70E+05 1.21E+04 O.OOE+OO ZR-95 1.07E+05 3.44E+04 2.33E+04 O.OOE+OO 5.42E+04 1. 77E+06 1.50E+05 O.OOE+OO ZR-97 9.68E+01 1.96E+01 9.04E+OO O.OOE+OO 2.97E+01 7.87E+04 5.23E+05 O.OOE+OO M0-93 O.OOE+OO 9.36E+03 2.54E+02 O.OOE+OO 2.84E+03 4.09E+05 3.03E+04 O.OOE+OO M0-99 O.OOE+OO 1.21 E+02 2.30E+01 O.OOE+OO 2.91 E+02 9.12E+04 2.48E+05 O.OOE+OO TC-99 2.50E+02 3.71E+02 1.00E+02 O.OOE+OO 4.68E+03 8.08E+05 6.03E+04 O.OOE+OO TC-99m 1.03E-03 2.91E-03 3.70E-02 O.OOE+OO 4.42E-02 7.64E+02 4.16E+03 O.OOE+OO TC-101 4.18E-05 6.02E-05 5.90E-04 O.OOE+OO 1.08E-03 3.99E+02 1.09E-11 O.OOE+OO RU-103 1.53E+03 O.OOE+OO 6.58E+02 O.OOE+OO 5.83E+03 5.05E+05 1.10E+05 O.OOE+OO RU-105 7.90E-01 O.OOE+OO 3.11E-01 O.OOE+OO 1.02E+OO 1.10E+04 4.82E+04 O.OOE+OO RU-106 6.91E+04 O.OOE+OO 8.72E+03 O.OOE+OO 1.34E+05 9.36E+06 9.12E+05 O.OOE+OO RH-105 7.39E+OO 5.38E+OO 3.54E+OO O.OOE+OO 2.29E+01 1.93E+04 8.72E+04 O.OOE+OO PD-107 O.OOE+OO 6.62E+02 4.70E+01 O.OOE+OO 5.26E+03 7.58E+04 5.65E+03 O.OOE+OO PD-109 O.OOE+OO 3. 70E+OO 9.28E-01 O.OOE+OO 1.88E+01 1.48E+04 1.22E+05 O.OOE+OO AG-110m 1.08E+04 1.00E+04 5.94E+03 O.OOE+OO 1.97E+04 4.63E+06 3.02E+05 O.OOE+OO AG-111 3.40E+02 1.42E+02 7.1 OE+01 O.OOE+OO 4.59E+02 1.86E+05 2.23E+05 O.OOE+OO CD-113m O.OOE+OO 1.23E+06 3.98E+04 O.OOE+OO 1.37E+06 1.66E+06 1.27E+05 O.OOE+OO CD-115m O.OOE+OO 1.97E+05 6.36E+03 O.OOE+OO 1.58E+05 1.41E+06 3.84E+05 O.OOE+OO SN-123 2.42E+05 5.34E+03 7.86E+03 4.54E+03 O.OOE+OO 2.30E+06 3.14E+05 O.OOE+OO SN-125 9.28E+03 2.50E+02 5.62E+02 2.07E+02 O.OOE+OO 5.90E+05 5.45E+05 O.OOE+OO SN-126 1.26E+06 3.34E+04 4.80E+04 9.84E+03 O.OOE+OO 9.36E+06 1.27E+05 O.OOE+OO SB-124 3.12E+04 5.89E+02 1.22E+04 7.55E+01 O.OOE+OO 2.48E+06 4.06E+05 O.OOE+OO SB-125 5.34E+04 5.95E+02 1.26E+04 5.40E+01 O.OOE+OO 1.74E+06 1.01 E+05 O.OOE+OO SB-126 3.60E+03 7.30E+01 1.30E+03 2.20E+01 O.OOE+OO 7.66E+05 4.81E+05 O.OOE+OO SB-127 2.64E+02 5.78E+OO 1.02E+02 3.18E+OO O.OOE+OO 1.64E+05 3.02E+05 O.OOE+OO TE-125m 3.42E+03 1.58E+03 4.67E+02 1.05E+03 1.24E+04 3.14E+05 7.06E+04 O.OOE+OO TE-127m 1.26E+04 5.77E+03 1.57E+03 3.29E+03 4.58E+04 9.60E+05 1.50E+05 O.OOE+OO TE-127 1.40E+OO 6.42E-01 3.10E-01 1.06E+OO 5.10E+OO 6.51 E+03 5.74E+04 O.OOE+OO TE-129m 9.76E+03 4.67E+03 1.58E+03 3.44E+03 3.66E+04 1.16E+06 3.83E+05 O.OOE+OO TE-129 4.98E-02 2.39E-02 1.24E-02 3.90E-02 1.87E-01 1.94E+03 1.57E+02 O.OOE+OO TE-133m
5. 79E-02 4.32E-02 3.34E-02 5.02E-02 2.99E-01 4.41 E+03 4.39E+02 O.OOE+OO 11.4-112 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-27 (Page 3 of 4)

Adult Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part 11, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 3.07E-02 2.58E-02 1.26E-02 2.75E-02 1.74E-01 3.47E+03 2.38E-01 O.OOE+OO 1.98E+04 1.69E+04 5.53E+04 4.43E+07 3.62E+04 O.OOE+OO 1.78E+03 O.OOE+OO 4.58E+03 1.34E+04 5.28E+03 1.14E+06 2.09E+04 O.OOE+OO 7.69E+03 O.OOE+OO 2.52E+04 3.58E+04 2.05E+04 1.19E+07 6.13E+04 O.OOE+OO 6.28E+03 O.OOE+OO TE-131 m 6.99E+01 4.36E+01 2.90E+01 5.50E+01 3.09E+02 1.46E+05 5.56E+05 O.OOE+OO TE-131 1.11 E-02 5.95E-03 3.59E-03 9.36E-03 4.37E-02 1.39E+03 1.84E+01 O.OOE+OO 1-132 1.16E+03 3.26E+03 1.16E+03 1.14E+05 5.18E+03 O.OOE+OO 4.06E+02 O.OOE+OO TE-132 2.60E+02 2.15E+02 1.62E+02 1.90E+02 1.46E+03 2.88E+05 5.10E+05 O.OOE+OO 1-133 8.64E+03 1.48E+04 4.52E+03 2.15E+06 2.58E+04 O.OOE+OO 8.88E+03 O.OOE+OO CS-134m 1.27E+02 2.56E+02 1.38E+02 O.OOE+OO 1.46E+02 2.34E+01 6.34E+01 O.OOE+OO CS-134 3.73E+05 8.48E+05 7.28E+05 O.OOE+OO 2.87E+05 9.76E+04 1.04E+04 O.OOE+OO 1-134 6.44E+02 1.73E+03 6.15E+02 2.98E+04 2.75E+03 O.OOE+OO 1.01E+OO O.OOE+OO 1-135 2.68E+03 6.98E+03 2.57E+03 4.48E+05 1.11 E+04 O.OOE+OO 5.25E+03 O.OOE+OO CS-135 1.17E+05 1.03E+05 4.79E+04 O.OOE+OO 4.09E+04 1.26E+04 1.69E+03 O.OOE+OO CS-136 3.90E+04 1.46E+05 1.10E+05 O.OOE+OO 8.56E+04 1.20E+04 1.17E+04 O.OOE+OO CS-137 4.78E+05 6.21E+05 4.28E+05 O.OOE+OO 2.22E+05 7.52E+04 8.40E+03 O.OOE+OO CS-138 3.31 E+02 6.21 E+02 3.24E+02 O.OOE+OO 4.80E+02 4.86E+01 1.86E-03 O.OOE+OO CS-139 2.05E+02 2.90E+02 1.11 E+02 O.OOE+OO 2.44E+02 2.27E+01 4.39E-21 O.OOE+OO BA-139 9.36E-01 6.66E-04 2.74E-02 O.OOE+OO 6.22E-04 3.76E+03 8.96E+02 O.OOE+OO BA-140 3.90E+04 4.90E+01 2.57E+03 O.OOE+OO 1.67E+01 1.27E+06 2.18E+05 O.OOE+OO LA-140 3.44E+02 1.74E+02 4.58E+01 O.OOE+OO O.OOE+OO 1.36E+05 4.58E+05 O.OOE+OO BA-141 1.00E-01 7.53E-05 3.36E-03 O.OOE+OO 7.00E-05 1.94E+03 1.16E-07 O.OOE+OO LA-141 4.27E+OO 1.33E+OO 2.17E-01 O.OOE+OO O.OOE+OO 1.08E+04 5.85E+04 O.OOE+OO CE-141 1.99E+04 1.35E+04 1.53E+03 O.OOE+OO 6.26E+03 3.62E+05 1.20E+05 O.OOE+OO BA-142 2.63E-02 2.70E-05 1.66E-03 O.OOE+OO 2.29E-05 1.19E+03 1.57E-16 O.OOE+OO LA-142 6.83E-01 3.10E-01 7.72E-02 O.OOE+OO O.OOE+OO 6.33E+03 2.11E+03 O.OOE+OO CE-143 1.86E+02 1.38E+02 1.53E+01 O.OOE+OO 6.08E+01 7.98E+04 2.26E+05 O.OOE+OO PR-143 9.36E+03 3.75E+03 4.64E+02 O.OOE+OO 2.16E+03 2.81E+05 2.00E+05 O.OOE+OO CE-144 3.43E+06 1.43E+06 1.84E+05 O.OOE+OO 8.48E+05 7.78E+06 8.16E+05 O.OOE+OO PR-144 3.01E-02 1.25E-02 1.53E-03 O.OOE+OO 7.05E-03 1.02E+03 2.15E-08 O.OOE+OO ND-147 5.27E+03 6.10E+03 3.65E+02 O.OOE+OO 3.56E+03 2.21E+05 1.73E+05 O.OOE+OO PM-147 6.70E+05 6.30E+04 2.55E+04 O.OOE+OO 1.19E+05 5.28E+05 4.43E+04 O.OOE+OO PM-148m 7.86E+04 2.03E+04 1.55E+04 O.OOE+OO 3.08E+04 1.71 E+06 3.34E+05 O.OOE+OO PM-148 3.07E+03 5.10E+02 2.56E+02 O.OOE+OO 9.60E+02 3.13E+05 4.64E+05 O.OOE+OO PM-149 2.75E+02 3.90E+01 1.59E+01 O.OOE+OO 7.35E+01 5.77E+04 2.00E+05 O.OOE+OO PM-151 6.80E+01 1.14E+01 5.77E+OO O.OOE+OO 2.04E+01 3.15E+04 1.60E+05 O.OOE+OO SM-151 6.87E+05 1.18E+05 2.84E+04 O.OOE+OO 1.33E+05 3.56E+05 2.60E+04 O.OOE+OO 11.4-113 LASALLE ODCM PART II SECTION 4.doc

Table 4-27 (Page 4 of 4)

Adult Inhalation Pi mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung Gl-Lll Skin SM-153 1.36E+02 1.14E+02 8.32E+OO O.OOE+OO 3.67E+01 3.31 E+04 1.26E+05 O.OOE+OO EU-152 1.90E+06 4.33E+05 3.81E+05 O.OOE+OO 2.68E+06 2.74E+06 1.27E+05 O.OOE+OO EU-154 5.92E+06 7.28E+05 5.18E+05 O.OOE+OO 3.49E+06 4.67E+06 2.72E+05 O.OOE+OO EU-155 8.08E+05 1.14E+05 7.37E+04 O.OOE+OO 5.27E+05 7.57E+05 4.76E+04 O.OOE+OO EU-156 1.54E+04 1.18E+04 1.92E+03 O.OOE+OO 7.96E+03 6.85E+05 3.60E+05 O.OOE+OO TB-160 1.77E+05 O.OOE+OO 2.20E+04 O.OOE+OO 7.28E+04 1.54E+06 2.14E+05 O.OOE+OO H0-166m 2.70E+06 8.40E+05 6.40E+05 O.OOE+OO 1.26E+06 3.15E+06 1.27E+05 O.OOE+OO W-181 4.98E+01 1.62E+01 1.74E+OO O.OOE+OO O.OOE+OO 1.37E+04 2.02E+03 O.OOE+OO W-185 1.56E+03 5.18E+02 5.45E+01 O.OOE+OO O.OOE+OO 4.46E+05 8.56E+04 O.OOE+OO W-187 8.48E+OO 7.08E+OO 2.48E+OO O.OOE+OO O.OOE+OO 2.90E+04 1.55E+05 O.OOE+OO NP-239 2.30E+02 2.26E+01 1.24E+01 O.OOE+OO 7.00E+01 3.76E+04 1.19E+05 O.OOE+OO U-232 4.11 E+08 O.OOE+OO 2.93E+07 O.OOE+OO 4.45E+07 1. 78E+09 3.37E+05 O.OOE+OO U-233 8.72E+07 O.OOE+OO 5.28E+06 O.OOE+OO 2.03E+07 4.26E+08 3.11E+05 O.OOE+OO U-234 8.32E+07 O.OOE+OO 5.17E+06 O.OOE+OO 1.99E+07 4.18E+08 3.05E+05 O.OOE+OO U-235 8.00E+07 O.OOE+OO 4.86E+06 O.OOE+OO 1.87E+07 3.92E+08 3.87E+05 O.OOE+OO U-236 8.00E+07 O.OOE+OO 4.96E+06 O.OOE+OO 1.91E+07 4.00E+08 2.86E+05 O.OOE+OO U-237 2.94E+02 O.OOE+OO 7.82E+01 O.OOE+OO 1.21 E+03 8.16E+04 9.60E+04 O.OOE+OO U-238 7.66E+07 O.OOE+OO 4.54E+06 O.OOE+OO 1.74E+07 3.66E+08 2.73E+05 O.OOE+OO NP-237 1.25E+10 8.00E+09 5.50E+08 O.OOE+OO 4.08E+09 4.18E+08 3.94E+05 O.OOE+OO NP-238 2.37E+03 5.76E+02 3.69E+01 O.OOE+OO 2.18E+02 8.16E+04 1.70E+05 O.OOE+OO PU-238 1.14E+10 7.77E+09 5.52E+08 O.OOE+OO 2.37E+09 1.46E+09 3.62E+05 O.OOE+OO PU-239 1.33E+10 8.56E+09 6.20E+08 O.OOE+OO 2.64E+09 1.38E+09 3.30E+05 O.OOE+OO PU-240 1.32E+10 8.56E+09 6.18E+08 O.OOE+OO 2.63E+09 1.38E+09 3.37E+05 O.OOE+OO PU-241 2.74E+08 6.95E+07 1.03E+07 O.OOE+OO 4.74E+07 1.22E+06 6.92E+03 O.OOE+OO PU-242 1.22E+10 8.24E+09 5.97E+08 O.OOE+OO 2.54E+09 1.32E+09 3.24E+05 O.OOE+OO PU-244 1.43E+10 9.44E+09 6.83E+08 O.OOE+OO 2.91E+09 1.51E+09 4.82E+05 O.OOE+OO AM-241 1.34E+10 9.04E+09 5.37E+08 O.OOE+OO 4.03E+09 4.85E+08 3.68E+05 O.OOE+OO AM-242m 1.36E+10 8.48E+09 5.38E+08 O.OOE+OO 4.01E+09 1.95E+08 4.63E+05 O.OOE+OO AM-243 1.34E+10 8.80E+09 5.26E+08 O.OOE+OO 3.96E+09 4.60E+08 4.32E+05 O.OOE+OO CM-242

1. 78E+08 1.42E+08 7.87E+06 O.OOE+OO 3.58E+07 3.14E+08 3.93E+05 O.OOE+OO CM-243 8.80E+09 6.09E+09 3.69E+08 O.OOE+OO 1.72E+09 5.05E+08 3.87E+05 O.OOE+OO CM-244 6.70E+09 4.70E+09 2.81 E+08 O.OOE+OO 1.31 E+09 4.85E+08 3.74E+05 O.OOE+OO CM-245 1.39E+10 9.12E+09 5.71E+08 O.OOE+OO 2.66E+09 4.68E+08 3.49E+05 O.OOE+OO CM-246 1.38E+10 9.12E+09 5. 70E+08 O.OOE+OO 2.66E+09 4. 77E+08 3.43E+05 O.OOE+OO CM-247 1.34E+10 8.96E+09 5.62E+08 O.OOE+OO 2.62E+09 4.68E+08 4.50E+05 O.OOE+OO CM-248 1.12E+11 7.41E+10 4.63E+09 O.OOE+OO 2.16E+10 3.86E+09 7.27E+06 O.OOE+OO CF-252 4.34E+09 O.OOE+OO 1.86E+08 O.OOE+OO O.OOE+OO 1.59E+09 1.42E+06 O.OOE+OO ll.4-114 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-28 (Page 1 of 4)

All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.16E+10 1.31E+10 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.19E+07 1.39E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 1.98E+10 2.33E+10 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 8.33E+08 9.61E+08 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 4.66E+06 5.51 E+06 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.39E+09 1.63E+09 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 9.03E+05 1.07E+06 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 1.88E+08 2.07E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 3.79E+08 4.44E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 2.73E+08 3.21E+08 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.45E+10 2.89E+10 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.07E+05 6.88E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 2.97E+05 3.45E+05 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 7.47E+08 8.59E+08 ZN-69m 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.27E+06 1.49E+06 ZN-69 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SE-79 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.14E+07 2.47E+07 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 7.08E+03 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.03E+05 2.36E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 8.99E+06 1.03E+07 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.31E+04 3.78E+04 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.23E+05 1.48E+05 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.16E+04 2.51 E+04 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 4.49E+03 5.31 E+03 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.15E+06 2.51 E+06 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.00E+05 1.16E+05 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.07E+06 1.21 E+06 11.4-115 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-28 (Page 2 of 4)

All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 7.77E+05 8.63E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 1.80E+05 2.14E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 1.83E+05 2.51E+05 NB-93m 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 2.54E+06 3.09E+08 NB-95 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.37E+08 1.61 E+08 NB-97 ZR-93 ZR-95 ZR-97 M0-93 M0-99 TC-99

1. 76E+05 1. 76E+05 1. 76E+05 1. 76E+05 1. 76E+05 1. 76E+05 1. 76E+05 2.07E+05 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.45E+08 2.84E+08 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 2.96E+06 3.44E+06 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 1.32E+08 5.39E+09 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 3.99E+06 4.63E+06 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO TC-99m 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 1.84E+05 2.11 E+05 TC-101 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.04E+04 2.26E+04 RU-103 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.08E+08 1.26E+08 RU-105 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 6.36E+05 7.21E+05 RU-106 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 4.22E+08 5.07E+08 RH-105 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 7.43E+05 8.67E+05 PD-107 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO PD-109 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.50E+04 1.71E+04 AG-110m 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 3.44E+09 4.01 E+09 AG-111 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.03E+06 1.20E+06 CD-113m 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 6.87E+06 7.76E+06 CD-115m O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO SN-123 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 6.38E+09 SN-125 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.20E+06 4.86E+06 SN-126 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.22E+10 5.80E+10 SB-124 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 5.98E+08 6.90E+08 SB-125 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.40E+09 2.71E+09 SB-126 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 8.44E+07 9.48E+07 SB-127 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.68E+07 1.94E+07 TE-125m 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 1.55E+06 2.13E+06 TE-127m 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 9.16E+04 1.08E+05 TE-127 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 2.98E+03 3.28E+03 TE-129m 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 1.98E+07 2.31E+07 TE-129 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 2.62E+04 3.10E+04 TE-133m 4.41 E+05 4.41 E+05 4.41 E+05 4.41 E+05 4.41 E+05 4.41 E+05 4.41 E+05 5.00E+05 11.4-116 LASALLE ODCM PART II SECTION 4.doc

Table 4-28 (Page 3 of 4)

All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin TE-134 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.22E+04 2.66E+04 1-129 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 2.61E+09 4.35E+09 1-130 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 5.51 E+06 6.69E+06 1-131 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 1.72E+07 2.09E+07 TE-131m 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 8.03E+06 9.46E+06 TE-131 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 2.92E+04 3.45E+07 1-132 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.25E+06 1.46E+06 TE-132 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.23E+06 4.98E+06 1-133 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.45E+06 2.98E+06 CS-134m 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 5.73E+04 6.74E+04 CS-134 6.91 E+09 6.91 E+09 6.91 E+09 6.91 E+09 6.91 E+09 6.91 E+09 6.91 E+09 8.06E+09 1-134 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 4.47E+05 5.30E+05 1-135 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.53E+06 2.95E+06 CS-135 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CS-136 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.51E+08 1.71E+08 CS-137 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 1.76E+10 2.05E+10 CS-138 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 3.59E+05 4.1 OE+05 CS-139 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.59E+04 BA-139 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.06E+05 1.19E+05 BA-140 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.05E+07 2.35E+07 LA-140 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 1.92E+07 2.18E+07 BA-141 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.17E+04 4.75E+04 LA-141 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.14E+04 3.51E+04 CE-141 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.37E+07 1.54E+07 BA-142 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 4.49E+04 5.11 E+04 LA-142 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 7.60E+05 9.11 E+05 CE-143 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.31E+06 2.63E+06 PR-143 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO CE-144 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 6.95E+07 8.04E+07 PR-144 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 1.83E+03 2.11E+03 ND-147 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 8.39E+06 1.01 E+07 PM-147 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO PM-148m 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 4.45E+08 2.58E+09 PM-148 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 1.89E+07 2.18E+07 PM-149 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.23E+04 4.90E+04 PM-151 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 1.99E+06 2.08E+06 SM-151 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 2.49E+08 1.09E+09 11.4-117 LASALLE ODCM PART II SECTION 4.doc

Table 4-28 (Page 4 of 4)

All Age Groups Ground Plane Ri m2*mrem*sec/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LU Skin SM-153 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.02E+05 4.46E+05 EU-152 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.19E+10 2.54E+10 EU-154 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 1.74E+10 2.00E+10 EU-155 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.20E+08 5.90E+08 EU-156 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 8.82E+07 1.01 E+08 TB-160 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 4.75E+08 5.53E+08 H0-166m 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.12E+10 5.75E+10 W-181 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 1.94E+05 2.59E+05 W-185 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO W-187 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.35E+06 2.73E+06 NP-239 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.71E+06 1.98E+06 U-232 1.31 E+07 1.31 E+07 1.31 E+07 1.31 E+07 1.31 E+07 1.31 E+07 1.31 E+07 1.36E+08 U-233 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.33E+10 1.62E+10 U-234 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 3.67E+06 9.22E+08 U-235 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 1.86E+10 2.32E+10 U-236 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.22E+05 1.04E+08 U-237 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 5.16E+06 6.71 E+06 U-238 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 6.38E+08 8. 70E+08 NP-237 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 8.12E+09 9.28E+09 NP-238 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 4.53E+06 5.18E+06 PU-238 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 6.71E+06 9.30E+07 PU-239 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.58E+06 4.46E+07 PU-240 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 7.53E+06 1.04E+08 PU-241 1.41 E+07 1.41 E+07 1.41 E+07 1.41 E+07 1.41 E+07 1.41 E+07 1.41 E+07 2.09E+07 PU-242 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 6.38E+06 9.28E+07 PU-244 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.19E+09 5.58E+09 AM-241 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.02E+09 1.47E+09 AM-242m 1.41 E+08 1.41 E+08 1.41 E+08 1.41 E+08 1.41 E+08 1.41 E+08 1.41 E+08 9. 76E+OB AM-243 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 7.53E+09 8.69E+09 CM-242 6.86E+05 6.86E+05 6.86E+05 6.86E+05 6.B6E+05 6.86E+05 6.86E+05 2.87E+06 CM-243 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 9.47E+09 1.19E+10 CM-244 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 1.00E+07 6.21 E+07 CM-245 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 5.50E+09 6.95E+09 CM-246 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 5.79E+06 8.68E+07 CM-247 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.28E+10 1.51E+10 CM-248 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.03E+10 3.95E+10 CF-252 4.B6E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 4.86E+10 5.30E+10 11.4-118 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-29 (Page 1 of 4)

Infant Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 6.47E+02 O.OOE+OO 2.65E+04 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 5.31 E+03 O.OOE+OO 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 1.03E+05 O.OOE+OO 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 1.06E+04 O.OOE+OO 2.03E+06 1.12E+05 7.74E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.61E+04 O.OOE+OO 1.05E+05 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 9.72E+07 4.14E+02 O.OOE+OO 5.25E+05 7.57E+05 2.37E+05 O.OOE+OO 4.98E+05 O.OOE+OO 3.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.95E+01 5. 75E+01 1.32E+01 1.28E+04 3.57E+02 O.OOE+OO O.OOE+OO 2.53E+04 4.98E+03 O.OOE+OO 4.98E+03 1.00E+06 7.06E+03 O.OOE+OO 1.97E+04 1.18E+04 3.33E+03 O.OOE+OO O.OOE+OO 8.69E+04 1.10E+03 O.OOE+OO O.OOE+OO 1.54E+OO 2.21E-01 O.OOE+OO 1.10E+OO 1.25E+04 7.17E+04 O.OOE+OO O.OOE+OO 6.51E+02 6.41E+02 O.OOE+OO O.OOE+OO 3.79E+05 4.86E+03 O.OOE+OO O.OOE+OO 1.22E+03 1.82E+03 O.OOE+OO O.OOE+OO 7. 77E+05 1.11 E+04 O.OOE+OO 1.36E+04 2.35E+04 9.48E+03 O.OOE+OO O.OOE+OO 1.02E+06 2.48E+04 O.OOE+OO O.OOE+OO 8.02E+03 1.18E+04 O.OOE+OO O.OOE+OO 4.51 E+06 3.19E+04 O.OOE+OO 2.53E+04 7.62E+03 4.34E+03 O.OOE+OO O.OOE+OO 7.67E+04 8.88E+02 O.OOE+OO 3.39E+05 2.04E+04 1.16E+04 O.OOE+OO O.OOE+OO 2.09E+05 2.42E+03 O.OOE+OO O.OOE+OO 1.88E+OO 7.74E-01 O.OOE+OO 3.98E+OO 9.30E+03 1.50E+04 O.OOE+OO 2.39E+OO 2.84E-01 1.23E-01 O.OOE+OO O.OOE+OO 8.12E+03 5.01 E+04 O.OOE+OO 1.93E+04 6.26E+04 3.11 E+04 O.OOE+OO 3.25E+04 6.47E+05 5.14E+04 O.OOE+OO ZN-69m 1.26E+01 2.58E+01 2.34E+OO O.OOE+OO 1.04E+01 2.67E+04 4.09E+04 O.OOE+OO ZN-69 5.39E-02 9.67E-02 7.18E-03 O.OOE+OO 4.02E-02 1.47E+03 1.32E+04 O.OOE+OO SE-79 BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO 3.15E+03 5.88E+02 O.OOE+OO 3.46E+03 4.19E+05 4.84E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.33E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.40E-15 O.OOE+OO O.OOE+OO O.OOE+OO 3.81 E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.00E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.04E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.04E+03 O.OOE+OO O.OOE+OO 1.24E+05 4.93E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.37E+02 O.OOE+OO O.OOE+OO 5.57E+02 2.87E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.39E+02 O.OOE+OO O.OOE+OO 3.21 E+02 2.06E+02 O.OOE+OO O.OOE+OO O.OOE+OO 6.82E+01 O.OOE+OO 3.98E+05 O.OOE+OO 1.14E+04 O.OOE+OO O.OOE+OO 2.03E+06 6.40E+04 O.OOE+OO 4.09E+07 O.OOE+OO 2.59E+06 O.OOE+OO O.OOE+OO 1.12E+07 1.31 E+05 O.OOE+OO 3.29E+03 O.OOE+OO 8.82E+01 O.OOE+OO O.OOE+OO 2.69E+05 1.04E+05 O.OOE+OO 9.56E+01 O.OOE+OO 3.46E+OO O.OOE+OO O.OOE+OO 5.26E+04 7.34E+04 O.OOE+OO 4.07E-01 O.OOE+OO 1.39E-02 O.OOE+OO O.OOE+OO 2.79E+03 2.35E+03 O.OOE+OO 5.88E+05 O.OOE+OO 1.57E+04 O.OOE+OO O.OOE+OO 2.45E+06 7.03E+04 O.OOE+OO 11.4-119 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-29 (Page 2 of 4)

Infant Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 1.05E+01 O.OOE+OO 3.91 E-01 O.OOE+OO O.OOE+OO 2.38E+04 1.40E+05 O.OOE+OO 1.64E+01 O.OOE+OO 4.61 E-01 O.OOE+OO O.OOE+OO 2.45E+04 1.27E+05 O.OOE+OO 1.50E+02 O.OOE+OO 4.07E+OO O.OOE+OO O.OOE+OO 7.64E+04 1.67E+05 O.OOE+OO NB-93m 1.93E+05 5.03E+04 1.61 E+04 O.OOE+OO 5.15E+04 2.93E+05 3.46E+03 O.OOE+OO NB-95 1.57E+04 6.43E+03 3.78E+03 O.OOE+OO 4.72E+03 4.79E+05 1.27E+04 O.OOE+OO NB-97 3.42E-01 7.29E-02 2.63E-02 O.OOE+OO 5.70E-02 3.32E+03 2.69E+04 O.OOE+OO ZR-93 3.14E+05 1.33E+05 8.65E+04 O.OOE+OO 4.47E+05 1.92E+06 2.07E+04 O.OOE+OO ZR-95 1.15E+05 2.79E+04 2.03E+04 O.OOE+OO 3.11E+04 1.75E+06 2.17E+04 O.OOE+OO ZR-97 1.50E+02 2.56E+01 1.17E+01 O.OOE+OO 2.59E+01 1.1 OE+05 1.40E+05 O.OOE+OO M0-93 O.OOE+OO 9.04E+03 3.11 E+02 O.OOE+OO 2.16E+03 4.76E+05 5.26E+03 O.OOE+OO M0-99 O.OOE+OO 1.65E+02 3.23E+01 O.OOE+OO 2.65E+02 1.35E+05 4.87E+04 O.OOE+OO TC-99 2.93E+02 3. 75E+02 1.24E+02 O.OOE+OO 3.49E+03 9.48E+05 1.09E+04 O.OOE+OO TC-99m 1.40E-03 2.88E-03 3.72E-02 O.OOE+OO 3.11E-02 8.11E+02 2.03E+03 O.OOE+OO TC-101 6.51E-05 8.23E-05 8.12E-04 O.OOE+OO 9.79E-04 5.84E+02 8.44E+02 O.OOE+OO RU-103 2.02E+03 O.OOE+OO 6.79E+02 O.OOE+OO 4.24E+03 5.52E+05 1.61E+04 O.OOE+OO RU-105 1.22E+OO O.OOE+OO 4.10E-01 O.OOE+OO 8.99E-01 1.57E+04 4.84E+04 O.OOE+OO RU-106 8.68E+04 O.OOE+OO 1.09E+04 O.OOE+OO 1.07E+05 1.16E+07 1.64E+05 O.OOE+OO RH-105 1.16E+01 7.57E+OO 5.08E+OO O.OOE+OO 2.10E+01 2.91E+04 1.92E+04 O.OOE+OO PD-107 O.OOE+OO 6.89E+01 5.75E+01 O.OOE+OO 3.85E+03 8.88E+04 1.03E+03 O.OOE+OO PD-109 O.OOE+OO 5.49E+OO 1.47E+OO O.OOE+OO 1.79E+01 2.35E+04 3.99E+04 O.OOE+OO AG-110m 9.98E+03 7.22E+03 5.00E+03 O.OOE+OO 1.09E+04 3.67E+06 3.30E+04 O.OOE+OO AG-111 5.25E+02 2.03E+02 1.09E+02 O.OOE+OO 4.27E+02 2.88E+05 4.23E+04 O.OOE+OO CD-113m O.OOE+OO 9.34E+05 3.70E+04 O.OOE+OO 8.12E+05 1.96E+06 2.31E+04 O.OOE+OO CD-115m O.OOE+OO 2.42E+05 8.67E+03 O.OOE+OO 1.32E+05 2.06E+06 7.03E+04 O.OOE+OO SN-123 2.93E+05 5.89E+03 1.02E+04 5.98E+03 O.OOE+OO 3.11 E+06 5. 71 E+04 O.OOE+OO SN-125 1.41 E+04 3.51 E+02 8.40E+02 3.46E+02 O.OOE+OO 9.00E+05 1.02E+05 O.OOE+OO SN-126 1.16E+06 2.02E+04 4.93E+04 5.38E+03 O.OOE+OO 6.90E+06 2.31E+04 O.OOE+OO SB-124 3.79E+04 5.56E+02 1.20E+04 1.01E+02 O.OOE+OO 2.65E+06 5.91E+04 O.OOE+OO SB-125 5.45E+04 4. 77E+02 1.09E+04 6.23E+01 O.OOE+OO 1.64E+06 1.47E+04 O.OOE+OO SB-126 4.31E+03 8.41E+01 1.55E+02 3.29E+01 O.OOE+OO 9.63E+05 7.46E+04 O.OOE+OO SB-127 3.95E+02 7.06E+OO 1.23E+02 5.04E+OO O.OOE+OO 2.16E+05 5.29E+04 O.OOE+OO TE-125m 4.76E+03 1.99E+03 6.58E+02 1.62E+03 O.OOE+OO 4.47E+05 1.29E+04 O.OOE+OO TE-127m 1.67E+04 6.90E+03 2.07E+03 4.87E+03 3.75E+04 1.31E+06 2.73E+04 O.OOE+OO TE-127 2.23E+OO 9.53E-01 4.89E-01 1.85E+OO 4.86E+OO 1.04E+04 2.44E+04 O.OOE+OO TE-129m 1.41 E+04 6.09E+03 2.23E+03 5.47E+03 3.18E+04 1.68E+06 6.90E+04 O.OOE+OO TE-129 7.88E-02 3.47E-02 1.88E-02 6.75E-02 1.75E-01 3.00E+03 2.63E+04 O.OOE+OO TE-133m 8.58E-02 5.03E-02 3.84E-02 7.73E-02 2.41E-01 5.49E+03 2.23E+04 O.OOE+OO 11.4-120 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-29 (Page 3 of 4)

Infant Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 4.45E-02 2.86E-02 2.35E-02 4.07E-02 1.34E-01 4.10E+03 3.54E+03 O.OOE+OO 3.02E+04 2.23E+04 1.62E+04 1.46E+07 2.63E+04 O.OOE+OO 2.97E+02 O.OOE+OO 6.36E+03 1.39E+04 5.57E+03 1.60E+06 1.53E+04 O.OOE+OO 1.99E+03 O.OOE+OO

3. 79E+04 4.44E+04 1.96E+04 1.48E+07 5.18E+04 O.OOE+OO 1.06E+03 O.OOE+OO TE-131m 1.07E+02 5.50E+01 3.63E+01 8.93E+01 2.65E+02 1.99E+05 1.19E+05 O.OOE+OO TE-131 1.74E-02 8.22E-03 5.00E-03 1.58E-02 3.99E-02 2.06E+03 8.22E+03 O.OOE+OO 1-132 1.69E+03 3.54E+03 1.26E+03 1.69E+05 3.95E+03 O.OOE+OO 1.90E+03 O.OOE+OO TE-132
3. 72E+02 2.37E+02 1. 76E+02 2. 79E+02 1.04E+03 3.40E+05 4.41 E+04 O.OOE+OO 1-133 1.32E+04 1.92E+04 5.60E+03 3.56E+06 2.24E+04 O.OOE+OO 2.16E+03 O.OOE+OO CS-134m 1.85E+02 2.94E+02 1.55E+02 O.OOE+OO 1.19E+02 2.80E+01 1.62E+02 O.OOE+OO CS-134 3.96E+05 7.03E+05 7.45E+04 O.OOE+OO 1.90E+05 7.97E+04 1.33E+03 O.OOE+OO 1-134 9.21 E+02 1.88E+03 6.65E+02 4.45E+04 2.09E+03 O.OOE+OO 1.29E+03 O.OOE+OO 1-135 3.86E+03 7.60E+03 2.77E+03 6.96E+05 8.47E+03 O.OOE+OO 1.83E+03 O.OOE+OO CS-135 1.40E+05 1.21E+05 6.62E+03 O.OOE+OO 3.61E+04 1.41E+04 3.05E+02 O.OOE+OO CS-136 4.83E+04 1.35E+05 5.29E+04 O.OOE+OO 5.64E+04 1.18E+04 1.43E+03 O.OOE+OO CS-137 5.49E+05 6.12E+05 4.55E+04 O.OOE+OO 1.72E+05 7.13E+04 1.33E+03 O.OOE+OO CS-138 5.05E+02 7.81E+02 3.98E+02 O.OOE+OO 4.10E+02 6.54E+01 8.76E+02 O.OOE+OO CS-139 3.25E+02 4.24E+02 1.71E+02 O.OOE+OO 2.31E+02 3.54E+01 1.86E+01 O.OOE+OO BA-139 1.48E+OO 9.84E-04 4.30E-02 O.OOE+OO 5.92E-04 5.95E+03 5.10E+04 O.OOE+OO BA-140 5.60E+04 5.60E+01 2.90E+03 O.OOE+OO 1.34E+01 1.60E+06 3.84E+04 O.OOE+OO LA-140 5.05E+02 2.00E+02 5.15E+01 O.OOE+OO O.OOE+OO 1.68E+05 8.48E+04 O.OOE+OO BA-141 1.57E-01 1.08E-04 4.97E-03 O.OOE+OO 6.50E-05 2.97E+03 4.75E+03 O.OOE+OO LA-141 6.79E+OO 1.96E+OO 3.43E-01 O.OOE+OO O.OOE+OO 1.71E+04 8.34E+04 O.OOE+OO CE-141 2.77E+04 1.67E+04 1.99E+03 O.OOE+OO 5.25E+03 5.17E+05 2.16E+04 O.OOE+OO BA-142 3.98E-02 3.30E-05 1.96E-03 O.OOE+OO 1.90E-05 1.55E+03 6.93E+02 O.OOE+OO LA-142 1.03E+OO 3.77E-01 9.04E-02 O.OOE+OO O.OOE+OO 8.22E+03 5.95E+04 O.OOE+OO CE-143 2.93E+02 1.93E+02 2.21E+01 O.OOE+OO 5.64E+01 1.16E+05 4.97E+04 O.OOE+OO PR-143 1.40E+04 5.24E+03 6.99E+02 O.OOE+OO 1.97E+03 4.33E+05 3.72E+04 O.OOE+OO CE-144 3.19E+06 1.21E+06 1.76E+05 O.OOE+OO 5.38E+05 9.84E+06 1.48E+05 O.OOE+OO PR-144 4.79E-02 1.85E-02 2.41E-03 O.OOE+OO 6.72E-03 1.61E+03 4.28E+03 O.OOE+OO ND-147 7.94E+03 8.13E+03 5.00E+02 O.OOE+OO 3.15E+03 3.22E+05 3.12E+04 O.OOE+OO PM-147 5.47E+05 4.30E+04 2.18E+04 O.OOE+OO 6.90E+04 6.37E+05 8.05E+03 O.OOE+OO PM-148m 7.00E+04 1.74E+04 1.39E+04 O.OOE+OO 2.03E+04 1.71E+06 4.72E+04 O.OOE+OO PM-148 4.68E+03 6.75E+01 3.42E+02 O.OOE+OO 8.06E+02 4.48E+05 8.46E+04 O.OOE+OO PM-149 4.34E+02 5.71E+01 2.49E+01 O.OOE+OO 6.94E+01 9.10E+04 4.21E+04 O.OOE+OO PM-151 1.05E+02 1.54E+01 7.77E+OO O.OOE+OO 1.82E+01 4.55E+04 3.61 E+04 O.OOE+OO SM-151 4.73E+05 9.03E+04 2.28E+04 O.OOE+OO 7.34E+04 4.17E+05 4.84E+03 O.OOE+OO 11.4-121 LASALLE ODCM PART II SECTION 4.doc

Table 4-29 (Page 4 of 4)

Infant Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung GI-LU Skin SM-153 2.14E+02 1.65E+02 1.27E+01 O.OOE+OO 3.46E+01 5.18E+04 2.70E+04 O.OOE+OO EU-152 1.10E+06 2.48E+05 2.41E+05 O.OOE+OO 8.32E+05 2.07E+06 1.38E+04 O.OOE+OO EU-154 4.14E+06 4.84E+05 3.43E+05 O.OOE+OO 1.60E+06 4.27E+06 3.98E+04 O.OOE+OO EU-155 8.36E+05 8.01E+04 4.84E+04 O.OOE+OO 2.21E+05 7.28E+05 7.27E+04 O.OOE+OO EU-156 2.18E+04 1.34E+04 2.16E+03 O.OOE+OO 6.27E+03 8.57E+05 5.80E+04 O.OOE+OO TB-160 1.57E+05 O.OOE+OO 1.96E+04 O.OOE+OO 4.48E+04 1.55E+06 3.00E+04 O.OOE+OO H0-166m 2.03E+05 4.30E+05 3.51 E+05 O.OOE+OO 5.91 E+05 2.87E+06 2.31 E+04 O.OOE+OO W-181 6.80E+01 2.04E+01 2.34E+OO O.OOE+OO O.OOE+OO 1.86E+04 3.68E+02 O.OOE+OO W-185 2.20E+03 6.76E+02 7.81E+01 O.OOE+OO O.OOE+OO 6.27E+05 1.57E+04 O.OOE+OO W-187 1.30E+01 9.02E+OO 3.12E+OO O.OOE+OO O.OOE+OO 3.96E+04 3.56E+04 O.OOE+OO NP-239 3.71E+02 3.32E+01 1.88E+01 O.OOE+OO 6.62E+01 5.95E+04 2.49E+04 O.OOE+OO U-232 3.60E+08 O.OOE+OO 2.98E+07 O.OOE+OO 3.36E+07 2.09E+09 6.1 OE+04 O.OOE+OO U-233 7.62E+07 O.OOE+OO 5.36E+06 O.OOE+OO 1.53E+07 4.98E+08 5.64E+04 O.OOE+OO U-234 7.31 E+07 O.OOE+OO 5.25E+06 O.OOE+OO 1.50E+07 4.89E+08 5.53E+04 O.OOE+OO U-235 7.01 E+07 O.OOE+OO 4.93E+06 O.OOE+OO 1.41 E+07 4.59E+08 7.03E+04 O.OOE+OO U-236 7.01 E+07 O.OOE+OO 5.04E+06 O.OOE+OO 1.44E+07 4.69E+08 5.19E+04 O.OOE+OO U-237 4.55E+02 O.OOE+OO 1.21 E+02 O.OOE+OO 1.13E+03 1.28E+05 1.83E+04 O.OOE+OO U-238 6.71E+07 O.OOE+OO 4.61E+06 O.OOE+OO 1.32E+07 4.28E+08 4.96E+04 O.OOE+OO NP-237 4.03E+09 2.39E+09 1.76E+08 O.OOE+OO 1.08E+09 4.89E+08 7.14E+04 O.OOE+OO NP-238 3.74E+03 8.47E+02 5.82E+01 O.OOE+OO 2.06E+02 1.29E+05 3.61 E+04 O.OOE+OO PU-238 3.77E+09 2.35E+09 1.78E+08 O.OOE+OO 6.50E+08 1.26E+09 6.57E+04 O.OOE+OO PU-239 4.10E+09 2.46E+09 1.88E+08 O.OOE+OO 6.93E+08 1.19E+09 5.99E+04 O.OOE+OO PU-240 4.1 OE+09 2.45E+09 1.88E+08 O.OOE+OO 6.92E+08 1.19E+09 6.1 OE+04 O.OOE+OO PU-241 1.18E+08 2.59E+07 4.35E+06 O.OOE+OO 1.61 E+07 1.07E+06 1.26E+03 O.OOE+OO PU-242 3.81 E+09 2.37E+09 1.81 E+08 O.OOE+OO 6.68E+08 1.14E+09 5.88E+04 O.OOE+OO PU-244 4.44E+09 2.72E+09 2.07E+08 O.OOE+OO 7.64E+08 1.31E+09 8.76E+04 O.OOE+OO AM-241 4.41 E+09 2. 73E+09 1.83E+08 O.OOE+OO 1.11 E+09 5.68E+08 6.69E+04 O.OOE+OO AM-242m 4.55E+09 2.60E+09 1.89E+08 O.OOE+OO 1.12E+09 2.30E+08 8.41 E+04 O.OOE+OO AM-243 4.34E+09 2.63E+09 1.78E+08 O.OOE+OO 1.08E+09 5.39E+08 7.84E+04 O.OOE+OO CM-242 1.79E+08 1.21 E+08 7.98E+06 O.OOE+OO 2.37E+07 4.16E+08 7.14E+04 O.OOE+OO CM-243 3.46E+09 2.13E+09 1.48E+08 O.OOE+OO 5.47E+08 5.94E+08 7.03E+04 O.OOE+OO CM-244 2.90E+09 1.78E+09 1.24E+08 O.OOE+OO 4.49E+08 5.71 E+08 6.80E+04 O.OOE+OO CM-245 4.51E+09 2.74E+09 1.90E+08 O.OOE+OO 7.32E+08 5.49E+08 6.34E+04 O.OOE+OO CM-246 4.48E+09 2.74E+09 1.90E+08 O.OOE+OO 7.32E+08 5.59E+08 6.23E+04 O.OOE+OO CM-247 4.35E+09 2.70E+09 1.86E+08 O.OOE+OO 7.21E+08 5.49E+08 8.19E+04 O.OOE+OO CM-248 3.61 E+10 2.23E+10 1.54E+09 O.OOE+OO 5.94E+09 4.52E+09 1.32E+06 O.OOE+OO CF-252 3.32E+09 O.OOE+OO 1.41 E+08 O.OOE+OO O.OOE+OO 1.92E+09 2.59E+05 O.OOE+OO 11.4-122 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table 4-30 (Page 1 of 4)

Child Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin O.OOE+OO 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 1.13E+03 O.OOE+OO 3.59E+04 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 6.73E+03 O.OOE+OO 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 1.63E+05 O.OOE+OO 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 1.61E+04 O.OOE+OO 2.61 E+06 1.14E+05 9.88E+04 O.OOE+OO O.OOE+OO O.OOE+OO 4.22E+04 O.OOE+OO 2.61 E+05 O.OOE+OO 2.85E+04 O.OOE+OO O.OOE+OO 2.67E+08 1.09E+03 O.OOE+OO 7.29E+05 9.99E+05 3.85E+05 O.OOE+OO 8.84E+05 O.OOE+OO 9.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.54E+02 8.55E+01 2.43E+01 1.70E+04 1.08E+03 O.OOE+OO O.OOE+OO 4.29E+04 9.51 E+03 O.OOE+OO 1.00E+04 1.58E+06 2.29E+04 O.OOE+OO 4.74E+04 2.52E+04 7.77E+03 O.OOE+OO O.OOE+OO 1.11E+05 2.87E+03 O.OOE+OO O.OOE+OO 1.66E+OO 3.12E-01 O.OOE+OO 1.67E+OO 1.31 E+04 1.23E+05 O.OOE+OO O.OOE+OO 9.03E+02 1.07E+03 O.OOE+OO O.OOE+OO 5.07E+05 1.32E+04 O.OOE+OO O.OOE+OO 1.77E+03 3.16E+03 O.OOE+OO O.OOE+OO 1.11E+06 3.44E+04 O.OOE+OO 2.07E+04 3.35E+04 1.67E+04 O.OOE+OO O.OOE+OO 1.27E+06 7.07E+04 O.OOE+OO O.OOE+OO 1.31E+04 2.26E+04 O.OOE+OO O.OOE+OO 7.07E+06 9.62E+04 O.OOE+OO 6.14E+04 1.73E+04 1.05E+04 O.OOE+OO O.OOE+OO 1.01E+05 2.33E+03 O.OOE+OO 8.21E+05 4.63E+04 2.80E+04 O.OOE+OO O.OOE+OO 2.75E+05 6.33E+03 O.OOE+OO O.OOE+OO 1.99E+OO 1.07E+OO O.OOE+OO 6.03E+OO 9.58E+03 3.67E+04 O.OOE+OO 2.99E+OO 2.96E-01 1.64E-01 O.OOE+OO O.OOE+OO 8.18E+03 8.40E+04 O.OOE+OO 4.26E+04 1.13E+05 7.03E+04 O.OOE+OO 7.14E+04 9.95E+05 1.63E+04 O.OOE+OO ZN-69m 1.58E+01 2.69E+01 3.18E+OO O.OOE+OO 1.56E+01 2.72E+04 1.00E+05 O.OOE+OO ZN-69 6.70E-02 9.66E-02 8.92E-03 O.OOE+OO 5.85E-02 1.42E+03 1.02E+04 O.OOE+OO SE-79 O.OOE+OO 4.55E+03 9.62E+02 O.OOE+OO 6.33E+03 5.51 E+05 1.27E+04 O.OOE+OO BR-82 O.OOE+OO O.OOE+OO 2.09E+04 O.OOE+OO O.OOE+OO O.OOE+OO 3.70E-15 O.OOE+OO BR-83 O.OOE+OO O.OOE+OO 4.74E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO O.OOE+OO 5.48E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 2.53E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.98E+05 1.14E+05 O.OOE+OO O.OOE+OO O.OOE+OO 7.99E+03 O.OOE+OO O.OOE+OO 1.17E+05 5.07E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.10E+03 O.OOE+OO O.OOE+OO 5.62E+02 3.66E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.72E+01 O.OOE+OO O.OOE+OO 3.45E+02 2.90E+02 O.OOE+OO O.OOE+OO O.OOE+OO 1.89E+OO O.OOE+OO 5.99E+05 O.OOE+OO 1. 72E+04 O.OOE+OO O.OOE+OO 2.16E+06 1.67E+05 O.OOE+OO 1.01 E+08 O.OOE+OO 6.44E+06 O.OOE+OO O.OOE+OO 1.48E+07 3.43E+05 O.OOE+OO 4.11 E+03 O.OOE+OO 1.11 E+02 O.OOE+OO O.OOE+OO 2.62E+05 2.68E+05 O.OOE+OO 1.21 E+02 O.OOE+OO 4.59E+OO O.OOE+OO O.OOE+OO 5.33E+04 1.74E+05 O.OOE+OO 5.07E-01 O.OOE+OO 1.84E-02 O.OOE+OO O.OOE+OO 2.81 E+03 1. 72E+03 O.OOE+OO 9.14E+05 O.OOE+OO 2.44E+04 O.OOE+OO O.OOE+OO 2.63E+06 1.84E+05 O.OOE+OO 11.4-123 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-30 (Page 2 of 4)

Child Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 1.31 E+01 O.OOE+OO 5.25E-01 O.OOE+OO O.OOE+OO 2.40E+04 2.42E+05 O.OOE+OO 2.04E+01 O.OOE+OO 5.81 E-01 O.OOE+OO O.OOE+OO 2.39E+04 2.39E+05 O.OOE+OO 1.87E+02 O.OOE+OO 5.11 E+OO O.OOE+OO O.OOE+OO 7.44E+04 3.89E+05 O.OOE+OO NB-93m 4.70E+05 1.17E+05 3.85E+04 O.OOE+OO 1.26E+05 3.85E+05 9.07E+03 O.OOE+OO NB-95 2.35E+04 9.18E+03 6.55E+03 O.OOE+OO 8.62E+03 6.14E+05 3. 70E+04 O.OOE+OO NB-97 4.29E-01 7.70E-02 3.60E-02 O.OOE+OO 8.55E-02 3.42E+03 2.78E+04 O.OOE+OO ZR-93 7.66E+05 2.89E+05 2.05E+05 O.OOE+OO 1.11E+06 2.63E+06 5.44E+04 O.OOE+OO ZR-95 1.90E+05 4.18E+04 3.70E+04 O.OOE+OO 5.96E+04 2.23E+06 6.11E+04 O.OOE+OO ZR-97 1.88E+02 2.72E+01 1.60E+01 O.OOE+OO 3.89E+01 1.13E+05 3.51E+05 O.OOE+OO M0-93 O.OOE+OO 1.39E+04 5.00E+02 O.OOE+OO 3.92E+03 6.29E+05 1.40E+04 O.OOE+OO M0-99 O.OOE+OO 1.72E+02 4.26E+01 O.OOE+OO 3.92E+02 1.35E+05 1.27E+05 O.OOE+OO TC-99 4.96E+02 5.51 E+02 1.98E+02 O.OOE+OO 6.48E+03 1.25E+06 2.87E+04 O.OOE+OO TC-99m 1.78E-03 3.48E-03 5.77E-02 O.OOE+OO 5.07E-02 9.51E+02 4.81E+03 O.OOE+OO TC-101 8.1 OE-05 8.51 E-05 1.08E-03 O.OOE+OO 1.45E-03 5.85E+02 1.63E+01 O.OOE+OO RU-103 2.79E+03 O.OOE+OO 1.07E+03 O.OOE+OO 7.03E+03 6.62E+05 4.48E+04 O.OOE+OO RU-105 1.53E+OO O.OOE+OO 5.55E-01 O.OOE+OO 1.34E+OO 1.59E+04 9.95E+04 O.OOE+OO RU-106 1.36E+05 O.OOE+OO 1.69E+04 O.OOE+OO 1.84E+05 1.43E+07 4.29E+05 O.OOE+OO RH-105 1.45E+01 7.77E+OO 6.62E+OO O.OOE+OO 3.10E+01 2.89E+04 4.92E+04 O.OOE+OO PD-107 O.OOE+OO 9.81E+02 9.29E+01 O.OOE+OO 7.29E+03 1.17E+05 2.69E+03 O.OOE+OO PD-109 O.OOE+OO 5.48E+OO 1.83E+OO O.OOE+OO 2.61E+01 2.28E+04 9.58E+04 O.OOE+OO AG-110m 1.69E+04 1.14E+04 9.14E+03 O.OOE+OO 2.12E+04 5.48E+06 1.00E+05 O.OOE+OO AG-111 6.70E+02 2.10E+02 1.39E+02 O.OOE+OO 6.33E+02 2.86E+05 1.10E+05 O.OOE+OO CD-113m O.OOE+OO 1.82E+06 7.84E+04 O.OOE+OO 1.90E+06 2.57E+06 6.03E+04 O.OOE+OO CD-115m O.OOE+OO 2.92E+05 1.25E+04 O.OOE+OO 2.19E+05 2.17E+06 1.84E+05 O.OOE+OO SN-123 4.77E+05 7.92E+03 1.55E+04 8.40E+03 O.OOE+OO 3.55E+06 1.50E+05 O.OOE+OO SN-125 1.83E+04 3.68E+02 1.09E+03 3.81E+02 O.OOE+OO 8.99E+05 2.65E+05 O.OOE+OO SN-126 2.31E+06 3.85E+04 8.73E+04 1.05E+04 O.OOE+OO 1.12E+07 6.03E+04 O.OOE+OO SB-124 5.66E+06 7.40E+02 2.00E+04 1.26E+02 O.OOE+OO 3.24E+06 1.64E+05 O.OOE+OO SB-125 9.84E+04 7.59E+02 1.99E+04 9.10E+01 O.OOE+OO 2.32E+06 4.03E+04 O.OOE+OO SB-126 6.36E+03 9.69E+01 2.28E+03 3. 70E+01 O.OOE+OO 1.06E+06 2.1 OE+05 O.OOE+OO SB-127 5.03E+02 7.73E+OO 1.74E+02 5.59E+OO O.OOE+OO 2.28E+05 1.41E+05 O.OOE+OO TE-125m 6.73E+03 2.33E+03 9.14E+02 1.92E+03 O.OOE+OO 4.77E+05 3.38E+04 O.OOE+OO TE-127m 2.49E+04 8.55E+03 3.02E+03 6.07E+03 6.36E+04 1.48E+06 7.14E+04 O.OOE+OO TE-127 2.77E+OO 9.51E-01 6.11E-01 1.96E+OO 7.07E+OO 1.00E+04 5.62E+04 O.OOE+OO TE-129m 1.92E+04 6.85E+03 3.04E+03 6.33E+03 5.03E+04 1.76E+06 1.82E+05 O.OOE+OO TE-129 9.77E-02 3.50E-02 2.38E-02 7.14E-02 2.57E-01 2.93E+03 2.55E+04 O.OOE+OO TE-133m 1.08E-01 5.59E-02 5.55E-02 8.58E-02 3.74E-01 5.92E+03 1.76E+04 O.OOE+OO 11.4-124 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-30 (Page 3 of 4)

Child Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin 5.66E-02 3.26E-02 3.48E-02 4.59E-02 2.11 E-01 4.55E+03 1.80E+03 O.OOE+OO 3.89E+04 2.37E+04 2.11 E+04 1.58E+07 4.00E+04 O.OOE+OO 7.96E+02 O.OOE+OO 8.18E+03 1.64E+04 8.44E+03 1.85E+06 2.45E+04 O.OOE+OO 5.11 E+03 O.OOE+OO 4.81E+04 4.81E+04 2.73E+04 1.62E+07 7.88E+04 O.OOE+OO 2.84E+03 O.OOE+OO TE-131 m 1.34E+02 5.92E+01 5.07E+01 9. 77E+01 4.00E+02 2.06E+05 3.08E+05 O.OOE+OO TE-131 2.17E-02 8.44E-03 6.59E-03 1.?0E-02 5.88E-02 2.05E+03 1.33E+03 O.OOE+OO 1-132 2.12E+03 4.07E+03 1.88E+03 1.94E+05 6.25E+03 O.OOE+OO 3.20E+03 O.OOE+OO TE-132 4.81E+02 2.72E+02 2.63E+02 3.18E+02 1.77E+03 3.77E+05 1.38E+05 O.OOE+OO 1-133 1.66E+04 2.03E+04 7.70E+03 3.85E+06 3.38E+04 O.OOE+OO 5.48E+03 O.OOE+OO CS-134m 2.34E+02 3.30E+02 2.26E+02 O.OOE+OO 1.83E+02 3.09E+01 2.93E+02 O.OOE+OO CS-134 6.51 E+05 1.01 E+06 2.25E+05 O.OOE+OO 3.30E+05 1.21 E+05 3.85E+03 O.OOE+OO 1-134 1.17E+03 2.16E+03 9.95E+02 5.07E+04 3.30E+03 O.OOE+OO 9.55E+02 O.OOE+OO 1-135 4.92E+03 8.73E+03 4.14E+03 7.92E+05 1.34E+04 O.OOE+OO 4.44E+03 O.OOE+OO CS-135 2.31 E+05 1.53E+05 1.65E+04 O.OOE+OO 5.66E+04 1.93E+04 8.03E+02 O.OOE+OO CS-136 6.51E+04 1.71E+05 1.16E+05 O.OOE+OO 9.55E+04 1.45E+04 4.18E+03 O.OOE+OO CS-137 9.07E+05 8.25E+05 1.28E+05 O.OOE+OO 2.82E+05 1.04E+05 3.62E+03 O.OOE+OO CS-138 6.33E+02 8.40E+02 5.55E+02 O.OOE+OO 6.22E+02 6.81E+01 2.70E+02 O.OOE+OO CS-139 4.03E+02 4.26E+02 2.15E+02 O.OOE+OO 3.36E+02 3.46E+01 2.68E-02 O.OOE+OO BA-139 1.84E+OO 9.84E-04 5.37E-02 O.OOE+OO 8.62E-04 5.77E+03 5.77E+04 O.OOE+OO BA-140 7.40E+04 6.48E+01 4.33E+03 O.OOE+OO 2.11 E+01 1.74E+06 1.02E+05 O.OOE+OO LA-140 6.44E+02 2.25E+02 7.55E+01 O.OOE+OO O.OOE+OO 1.83E+05 2.26E+05 O.OOE+OO BA-141 1.96E-01 1.09E-04 6.36E-03 O.OOE+OO 9.47E-05 2.92E+03 2.75E+02 O.OOE+OO LA-141 8.47E+OO 1.96E+OO 4.26E-01 O.OOE+OO O.OOE+OO 1.66E+04 1.62E+05 O.OOE+OO CE-141 3.92E+04 1.95E+04 2.90E+03 O.OOE+OO 8.55E+03 5.44E+05 5.66E+04 O.OOE+OO BA-142 5.00E-02 3.60E-05 2.79E-03 O.OOE+OO 2.91E-05 1.64E+03 2.74E+OO O.OOE+OO LA-142 1.30E+OO 4.11 E-01 1.29E-01 O.OOE+OO O.OOE+OO 8.70E+03 7.59E+04 O.OOE+OO CE-143 3.66E+02 1.99E+02 2.88E+01 O.OOE+OO 8.36E+01 1.15E+05 1.27E+05 O.OOE+OO PR-143 1.85E+04 5.55E+03 9.14E+02 O.OOE+OO 3.00E+03 4.33E+05 9.73E+04 O.OOE+OO CE-144 6.77E+06 2.12E+06 3.62E+05 O.OOE+OO 1.17E+06 1.20E+07 3.89E+05 O.OOE+OO PR-144 5.96E-02 1.85E-02 3.00E-03 O.OOE+OO 9.77E-03 1.57E+03 1.97E+02 O.OOE+OO ND-147 1.08E+04 8.73E+03 6.81 E+02 O.OOE+OO 4.81 E+03 3.28E+05 8.21 E+04 O.OOE+OO PM-147 1.30E+06 9.32E+04 5.03E+04 O.OOE+OO 1.65E+05 8.14E+05 2.11 E+04 O.OOE+OO PM-148m 1.22E+05 2.42E+04 2.42E+04 O.OOE+OO 3.60E+04 2.12E+06 1.32E+05 O.OOE+OO PM-148 5.96E+03 7.18E+02 4.63E+02 O.OOE+OO 1.22E+03 4.59E+05 2.22E+05 O.OOE+OO PM-149 5.44E+02 5.77E+01 3.13E+01 O.OOE+OO 1.02E+02 8.88E+04 1.08E+05 O.OOE+OO PM-151 1.32E+02 1.60E+01 1.04E+01 O.OOE+OO 2. 72E+01 4.59E+04 9.55E+04 O.OOE+OO SM-151 1.16E+06 1.76E+05 5.51E+04 O.OOE+OO 1.81E+05 5.48E+05 1.27E+04 O.OOE+OO 11.4-125 LASALLE ODCM PART II SECTION 4.doc

Table 4-30 (Page 4 of 4)

Child Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin SM-153 2.68E+02 1.67E+02 1.61 E+01 O.OOE+OO 5.07E+01 5.07E+04 6.92E+04 O.OOE+OO EU-152 2.75E+06 5.07E+05 5.96E+05 O.OOE+OO 2.12E+06 3.33E+06 4.22E+04 O.OOE+OO EU-154 1.01 E+07 9.21 E+05 8.40E+05 O.OOE+OO 4.03E+06 6.14E+06 1.10E+05 O.OOE+OO EU-155 2.07E+06 1.50E+05 1.18E+05 O.OOE+OO 5.59E+05 1.03E+06 1.99E+05 O.OOE+OO EU-156 2.92E+04 1.57E+04 3.24E+03 O.OOE+OO 1.01 E+04 9.40E+05 1.57E+05 O.OOE+OO TB-160 2.88E+05 O.OOE+OO 3.58E+04 O.OOE+OO 8.58E+04 1.98E+06 8.44E+04 O.OOE+OO H0-166m 4.96E+06 1.04E+06 8.77E+05 O.OOE+OO 1.48E+06 4.18E+06 6.03E+04 O.OOE+OO W-181 9.84E+01 2.41 E+01 3.33E+OO O.OOE+OO O.OOE+OO 2.11 E+04 9.66E+02 O.OOE+OO W-185 3.07E+03 7.70E+02 1.08E+02 O.OOE+OO O.OOE+OO 6.88E+05 4.11E+04 O.OOE+OO W-187 1.63E+01 9.66E+OO 4.33E+OO O.OOE+OO O.OOE+OO 4.11E+04 9.10E+04 O.OOE+OO NP-239 4.66E+02 3.35E+01 2.35E+01 O.OOE+OO 9.73E+01 5.81E+04 6.40E+04 O.OOE+OO U-232 8.1 OE+08 O.OOE+OO 5. 77E+07 O.OOE+OO 6.18E+07 2. 75E+09 1.60E+05 O.OOE+OO U-233

1. 72E+08 O.OOE+OO 1.04E+07 O.OOE+OO 2.82E+07 6.55E+08 1.48E+05 O.OOE+OO U-234 1.65E+08 O.OOE+OO 1.02E+07 O.OOE+OO 2.76E+07 6.44E+08 1.45E+05 O.OOE+OO U-235 1.58E+08 O.OOE+OO 9.58E+06 O.OOE+OO 2.59E+07 6.03E+08 1.84E+05 O.OOE+OO U-236 1.58E+08 O.OOE+OO 9.81 E+06 O.OOE+OO 2.65E+07 6.18E+08 1.36E+05 O.OOE+OO U-237 5.81 E+02 O.OOE+OO 1.54E+02 O.OOE+OO 1.68E+03 1.26E+05 4. 77E+04 O.OOE+OO U-238 1.51 E+08 O.OOE+OO 8.95E+06 O.OOE+OO 2.42E+07 5.66E+08 1.30E+05 O.OOE+OO NP-237 1.01E+10 5.99E+09 4.40E+08 O.OOE+OO 2.74E+09 6.44E+08 1.87E+05 O.OOE+OO NP-238 4.66E+03 8.51 E+02 7.29E+01 O.OOE+OO 3.02E+02 1.25E+05 9.25E+04 O.OOE+OO PU-238 9.44E+09 5.92E+09 4.48E+08 O.OOE+OO 1.65E+09 2.25E+09 1. 72E+05 O.OOE+OO PU-239 1.03E+10 6.22E+09 4.74E+08 O.OOE+OO 1.77E+09 2.12E+09 1.57E+05 O.OOE+OO PU-240 1.03E+10 6.22E+09 4.70E+08 O.OOE+OO 1.76E+09 2.11E+09 1.60E+05 O.OOE+OO PU-241 2.94E+08 6.48E+07 1.08E+07 O.OOE+OO 4.07E+07 1.87E+06 3.29E+03 O.OOE+OO PU-242 9.58E+09 5.99E+09 4.55E+08 O.OOE+OO 1.70E+09 2.04E+09 1.54E+05 O.OOE+OO PU-244 1.12E+10 6.85E+09 5.22E+08 O.OOE+OO 1.95E+09 2.33E+09 2.29E+05 O.OOE+OO AM-241 1.10E+10 6.81E+09 4.59E+08 O.OOE+OO 2.82E+09 7.47E+08 1.75E+05 O.OOE+OO AM-242m 1.14E+10 6.51E+09 4.70E+08 O.OOE+OO 2.85E+09 3.01E+08 2.21E+05 O.OOE+OO AM-243 1.09E+10 6.59E+09 4.44E+08 O.OOE+OO 2. 75E+09 7.10E+08 2.05E+05 O.OOE+OO CM-242 3.51E+08 2.10E+08 1.55E+07 O.OOE+OO 4.96E+07 4.85E+08 1.87E+05 O.OOE+OO CM-243 8.58E+09 5.25E+09 3.68E+08 O.OOE+OO 1.38E+09 7. 77E+08 1.84E+05 O.OOE+OO CM-244 7.18E+09 4.37E+09 3.07E+08 O.OOE+OO 1.13E+09 7.47E+08 1. 78E+05 O.OOE+OO CM-245 1.13E+10 6.81E+09 4.74E+08 O.OOE+OO 1.86E+09 7.22E+08 1.66E+05 O.OOE+OO CM-246 1.12E+10 6.81 E+09 4.74E+08 O.OOE+OO 1.86E+09 7.36E+08 1.63E+05 O.OOE+OO CM-247 1.09E+10 6.73E+09 4.66E+08 O.OOE+OO 1.83E+09 7.22E+08 2.15E+05 O.OOE+OO CM-248 9.07E+10 5.55E+10 3.85E+09 O.OOE+OO 1.51E+10 5.96E+09 3.46E+06 O.OOE+OO CF-252 8.07E+09 O.OOE+OO 3.45E+08 O.OOE+OO O.OOE+OO 2.45E+09 6.81 E+05 O.OOE+OO 11.4-126 LASALLE ODCM PART II SECTION 4.doc

Nuclide H-3 C-14 NA-22 NA-24 P-32 CA-41 SC-46 CR-51 MN-54 FE-55 MN-56 C0-57 C0-58 FE-59 C0-60 Nl-59 Nl-63 CU-64 Nl-65 ZN-65 Table4-31(Page1 of4)

Teen Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin O.OOE+OO 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 1.27E+03 O.OOE+OO 2.60E+04 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 4.87E+03 O.OOE+OO 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 1.41 E+05 0. OOE+OO 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 1.38E+04 O.OOE+OO 1.89E+06 1.10E+05 7.16E+04 O.OOE+OO O.OOE+OO O.OOE+OO 9.28E+04 O.OOE+OO 3.24E+05 O.OOE+OO 3.50E+04 O.OOE+OO 1.08E+06 8.08E+08 2.38E+05 O.OOE+OO 5.79E+05 1.13E+06 3.34E+05 7.50E+01 3.07E+01 2.10E+04 3.00E+03 O.OOE+OO O.OOE+OO O.OOE+OO 1.35E+02 7.50E+01 3.07E+01 2.1 OE+04 3.00E+03 O.OOE+OO O.OOE+OO 5.11 E+04 8.40E+03 O.OOE+OO 1.27E+04 1.98E+06 6.68E+04 O.OOE+OO 3.34E+04 2.38E+04 5.54E+03 O.OOE+OO O.OOE+OO 1.24E+05 6.39E+03 O.OOE+OO O.OOE+OO 1. 70E+OO 2.52E-01 O.OOE+OO 1. 79E+OO 1.52E+04 5. 7 4E+04 O.OOE+OO O.OOE+OO 9.44E+02 9.20E+02 O.OOE+OO O.OOE+OO 5.86E+05 3.14E+04 O.OOE+OO O.OOE+OO 2.07E+03 2.78E+03 O.OOE+OO O.OOE+OO 1.34E+06 9.52E+04 O.OOE+OO 1.59E+04 3. 70E+04 1.43E+04 O.OOE+OO O.OOE+OO 1.53E+06 1. 78E+05 O.OOE+OO O.OOE+OO 1.51 E+04 1.98E+04 O.OOE+OO O.OOE+OO 8. 72E+06 2.59E+05 O.OOE+OO 4.35E+04 1.62E+04 7.39E+03 O.OOE+OO O.OOE+OO 1.13E+05 5.18E+03 O.OOE+OO 5.80E+05 4.34E+04 1.98E+04 O.OOE+OO O.OOE+OO 3.07E+05 1.42E+04 O.OOE+OO O.OOE+OO 2.03E+OO 8.48E-01 O.OOE+OO 6.41 E+OO 1.11 E+04 6.14E+04 O.OOE+OO 2.18E+OO 2.93E-01 1.27E-01 O.OOE+OO O.OOE+OO 9.36E+03 3.67E+04 O.OOE+OO 3.86E+04 1.34E+05 6.24E+04 O.OOE+OO 8.64E+04 1.24E+06 4.66E+04 O.OOE+OO ZN-69m 1.15E+01 2.47E+01 2.49E+OO O.OOE+OO 1.65E+01 3.14E+04 1.71E+05 O.OOE+OO ZN-69 4.83E-02 9.20E-02 6.46E-03 O.OOE+OO 6.02E-02 1.58E+03 2.85E+02 O.OOE+OO SE-79 BR-82 BR-83 BR-84 BR-85 RB-86 RB-87 RB-88 RB-89 SR-89 SR-90 Y-90 SR-91 Y-91m Y-91 O.OOE+OO 4.34E+03 6.97E+02 O.OOE+OO 6.50E+03 6.17E+05 2.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1.82E+04 O.OOE+OO O.OOE+OO O.OOE+OO 8.00E-15 O.OOE+OO O.OOE+OO O.OOE+OO 3.44E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 4.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.83E+01 O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO O.OOE+OO 1.90E+05 8.40E+04 O.OOE+OO O.OOE+OO O.OOE+OO 1. 77E+04 O.OOE+OO O.OOE+OO 1.12E+05 3.66E+04 O.OOE+OO O.OOE+OO O.OOE+OO 2.44E+03 O.OOE+OO O.OOE+OO 5.46E+02 2.72E+02 O.OOE+OO O.OOE+OO O.OOE+OO 2.92E-05 O.OOE+OO O.OOE+OO 3.52E+02 2.33E+02 O.OOE+OO O.OOE+OO O.OOE+OO 3.38E-07 O.OOE+OO 4.34E+05 O.OOE+OO 1.25E+04 O.OOE+OO O.OOE+OO 2.42E+06 3.71 E+05 O.OOE+OO 1.08E+08 O.OOE+OO 6.68E+06 O.OOE+OO O.OOE+OO 1.65E+07 7.65E+05 O.OOE+OO 2.98E+03 O.OOE+OO 8.00E+01 O.OOE+OO O.OOE+OO 2.93E+05 5.59E+05 O.OOE+OO 8.80E+01 O.OOE+OO 3.51 E+OO O.OOE+OO O.OOE+OO 6.07E+04 2.59E+05 O.OOE+OO 3.70E-01 O.OOE+OO 1.42E-02 O.OOE+OO O.OOE+OO 3.20E+03 3.02E+01 O.OOE+OO 6.61E+05 O.OOE+OO 1.77E+04 O.OOE+OO O.OOE+OO 2.94E+06 4.09E+05 O.OOE+OO 11.4-127 LASALLE ODCM PART II SECTION 4.doc

Nuclide SR-92 Y-92 Y-93 Table 4-31 (Page 2 of 4)

Teen Inhalation R; mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 9.52E+OO O.OOE+OO 4.06E-01 O.OOE+OO O.OOE+OO 2.74E+04 1.19E+05 O.OOE+OO 1.47E+01 O.OOE+OO 4.29E-01 O.OOE+OO O.OOE+OO 2.68E+04 1.65E+05 O.OOE+OO 1.35E+02 O.OOE+OO 3. 72E+OO O.OOE+OO O.OOE+OO 8.32E+04 5. 79E+05 O.OOE+OO NB-93m 3.31E+05 1.09E+05 2.73E+04 O.OOE+OO 1.27E+05 4.29E+05 2.02E+04 O.OOE+OO NB-95 1.86E+04 1.03E+04 5.66E+03 O.OOE+OO 1.00E+04 7.51 E+05 9.68E+04 O.OOE+OO NB-97 3.14E-01 7.78E-02 2.84E-02 O.OOE+OO 9.12E-02 3.93E+03 2.17E+03 O.OOE+OO ZR-93 5.46E+05 2.70E+05 1.47E+05 O.OOE+OO 9.28E+05 2.94E+06 1.28E+05 O.OOE+OO ZR-95 1.46E+05 4.58E+04 3.15E+04 O.OOE+OO 6.74E+04 2.69E+06 1.49E+05 O.OOE+OO ZR-97 1.38E+02 2.72E+01 1.26E+01 O.OOE+OO 4.12E+01 1.30E+05 6.30E+05 O.OOE+OO M0-93 O.OOE+OO 1.33E+04 3.62E+02 O.OOE+OO 4.05E+03 7.05E+05 3.19E+04 O.OOE+OO M0-99 O.OOE+OO 1.69E+02 3.22E+01 O.OOE+OO 4.11 E+02 1.54E+05 2.69E+05 O.OOE+OO TC-99 3.58E+02 5.26E+02 1.43E+02 O.OOE+OO 6.68E+03 1.39E+06 6.39E+04 O.OOE+OO TC-99m 1.38E-03 3.86E-03 4.99E-02 O.OOE+OO 5.76E-02 1.15E+03 6.13E+03 O.OOE+OO TC-101 5.92E-05 8.40E-05 8.24E-04 O.OOE+OO 1.52E-03 6.67E+02 8. 72E-07 O.OOE+OO RU-103 2.10E+03 O.OOE+OO 8.96E+02 O.OOE+OO 7.43E+03 7.83E+05 1.09E+05 O.OOE+OO RU-105 1.12E+OO O.OOE+OO 4.34E-01 O.OOE+OO 1.41 E+OO 1.82E+04 9.04E+04 O.OOE+OO RU-106 9.84E+04 O.OOE+OO 1.24E+04 O.OOE+OO 1.90E+05 1.61E+07 9.60E+05 O.OOE+OO RH-105 1.06E+01 7.58E+OO 4.99E+OO O.OOE+OO 3.23E+01 3.27E+04 9.84E+04 O.OOE+OO PD-107 O.OOE+OO 9.36E+02 6.71 E+01 O.OOE+OO 7.51 E+03 1.30E+05 5.99E+03 O.OOE+OO PD-109 O.OOE+OO 5.25E+OO 1.33E+OO O.OOE+OO 2.69E+01 2.55E+04 1.57E+05 O.OOE+OO AG-110m 1.38E+04 1.31E+04 7.99E+03 O.OOE+OO 2.50E+04 6.75E+06 2.73E+05 O.OOE+OO AG-111 4.86E+02 2.02E+02 1.02E+02 O.OOE+OO 6.54E+02 3.20E+05 2.40E+05 O.OOE+OO CD-113m O.OOE+OO 1.74E+06 5.68E+04 O.OOE+OO 1.94E+06 2.87E+06 1.34E+05 O.OOE+OO CD-115m O.OOE+OO 2.78E+05 9.12E+03 O.OOE+OO 2.26E+05 2.42E+06 4.08E+05 O.OOE+OO SN-123 3.45E+05 7.55E+03 1.12E+04 6.04E+03 O.OOE+OO 3.97E+05 3.33E+05 O.OOE+OO SN-125 1.33E+04 3.54E+02 7.99E+02 2.76E+02 O.OOE+OO 1.01E+06 5.83E+05 O.OOE+OO SN-126 1.74E+06 4.31 E+04 6.59E+04 1.14E+04 O.OOE+OO 1.38E+07 1.34E+05 O.OOE+OO SB-124 4.30E+04 7.94E+02 1.68E+04 9.76E+01 O.OOE+OO 3.85E+06 3.98E+05 O.OOE+OO SB-125 7.38E+04 8.08E+02 1.72E+04 7.04E+01 O.OOE+OO 2.74E+06 9.92E+04 O.OOE+OO SB-126 4.95E+03 1.02E+02 1.78E+03 2.80E+01 O.OOE+OO 1.24E+06 4.81E+05 O.OOE+OO SB-127 3.71E+02 7.94E+OO 1.40E+02 4.17E+OO O.OOE+OO 2.65E+05 3.15E+05 O.OOE+OO TE-125m 4.88E+03 2.24E+03 6.67E+02 1.40E+03 O.OOE+OO 5.36E+05 7.50E+04 O.OOE+OO TE-127m 1.80E+04 8.16E+03 2.18E+03 4.38E+03 6.54E+04 1.66E+06 1.59E+05 O.OOE+OO TE-127 2.01 E+OO 9.12E-01 4.42E-01 1.42E+OO 7.28E+OO 1.12E+04 8.08E+04 O.OOE+OO TE-129m 1.39E+04 6.58E+03 2.25E+03 4.58E+03 5.19E+04 1.98E+06 4.05E+05 O.OOE+OO TE-129 7.10E-02 3.38E-02 1.76E-02 5.18E-02 2.66E-01 3.30E+03 1.62E+03 O.OOE+OO TE-133m 8.08E-02 5.86E-02 4.57E-02 6.54E-02 2.46E-01 6.97E+03 9.84E+02 O.OOE+OO 11.4-128 LASALLE ODCM PART II SECTION 4.doc

Nuclide TE-134 1-129 1-130 1-131 Table 4-31 (Page 3 of 4)

Teen Inhalation R1 mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Bone Liver T Body Thyroid Kidney Lung GI-LU Skin 4.25E-02 3.48E-02 2.91 E-02 3.57E-02 2.33E-01 5.38E+03 1.1 OE+01 O.OOE+OO 2.82E+04 2.35E+04 7.12E+04 2.93E+07 4.21 E+04 O.OOE+OO 1.83E+03 O.OOE+OO 6.24E+03 1.79E+04 7.17E+03 1.49E+06 2.75E+04 O.OOE+OO 9.12E+03 O.OOE+OO 3.54E+04 4.91 E+04 2.64E+04 1.46E+07 8.40E+04 O.OOE+OO 6.49E+03 O.OOE+OO TE-131 m 9.84E+01 6.01 E+01 4.02E+01 7.25E+01 4.39E+02 2.38E+05 6.21 E+05 O.OOE+OO TE-131 1.58E-02 8.32E-03 5.04E-03 1.24E-02 6.18E-02 2.34E+03 1.51E+01 O.OOE+OO 1-132 1.59E+03 4.38E+03 1.58E+03 1.51 E+05 6.92E+03 O.OOE+OO 1.27E+03 O.OOE+OO TE-132 3.60E+02 2.90E+02 2.19E+02 2.46E+02 1.95E+03 4.49E+05 4.63E+05 O.OOE+OO 1-133 1.22E+04 2.05E+04 6.22E+03 2.92E+06 3.59E+04 O.OOE+OO 1.03E+04 O.OOE+OO CS-134m 1. 76E+02 3.48E+02 1.88E+02 O.OOE+OO 2.03E+02 3.65E+01 1.62E+02 O.OOE+OO CS-134 5.02E+05 1.13E+06 5.49E+05 O.OOE+OO 3.75E+05 1.46E+05 9.76E+03 O.OOE+OO 1-134 8.88E+02 2.32E+03 8.40E+02 3.95E+04 3.66E+03 O.OOE+OO 2.04E+01 O.OOE+OO 1-135 3.70E+03 9.44E+03 3.49E+03 6.21E+05 1.49E+04 O.OOE+OO 6.95E+03 O.OOE+OO CS-135 1.66E+05 1.46E+05 3.58E+04 O.OOE+OO 5.84E+04 2.16E+04 1.78E+03 O.OOE+OO CS-136 5.15E+04 1.94E+05 1.37E+05 O.OOE+OO 1.10E+05 1.78E+04 1.09E+04 O.OOE+OO CS-137

6. 70E+05 8.48E+05 3.11 E+05 O.OOE+OO 3.04E+05 1.21 E+05 8.48E+03 O.OOE+OO CS-138 4.66E+02 8.56E+02 4.46E+02 O.OOE+OO 6.62E+02 7.87E+01 2.70E-01 O.OOE+OO CS-139 2.92E+02 4.1 OE+02 1.58E+02 O.OOE+OO 3.47E+02 3.89E+01 1.33E-13 O.OOE+OO BA-139 1.34E+OO 9.44E-04 3.90E-02 O.OOE+OO 8.88E-04 6.46E+03 6.45E+03 O.OOE+OO BA-140 5.47E+04 6.70E+01 3.52E+03 O.OOE+OO 2.28E+01 2.03E+06 2.29E+05 O.OOE+OO LA-140 4.79E+02 2.36E+02 6.26E+01 O.OOE+OO O.OOE+OO 2.14E+05 4.87E+05 O.OOE+OO BA-141 1.42E-01 1.06E-04 4.74E-03 O.OOE+OO 9.84E-05 3.29E+03 7.46E-04 O.OOE+OO LA-141 6.10E+OO 1.88E+OO 3.10E-01 O.OOE+OO O.OOE+OO 1.85E+04 1.23E+05 O.OOE+OO CE-141 2.84E+04 1.90E+04 2.17E+03 O.OOE+OO 8.88E+03 6.14E+05 1.26E+05 O.OOE+OO BA-142 3.70E-02 3.70E-05 2.27E-03 O.OOE+OO 3.14E-05 1.91E+03 4.79E-10 O.OOE+OO LA-142 9.60E-01 4.25E-01 1.06E-01 O.OOE+OO O.OOE+OO 1.02E+04 1.20E+04 O.OOE+OO CE-143 2.66E+02 1.94E+02 2.16E+01 O.OOE+OO 8.64E+01 1.30E+05 2.55E+05 O.OOE+OO PR-143 1.34E+04 5.31E+03 6.62E+02 O.OOE+OO 3.09E+03 4.83E+05 2.14E+05 O.OOE+OO CE-144 4.89E+06 2.02E+06 2.62E+05 O.OOE+OO 1.21 E+06 1.34E+07 8.64E+05 O.OOE+OO PR-144 4.30E-02 1.76E-02 2.18E-03 O.OOE+OO 1.01E-02 1.75E+03 2.35E-04 O.OOE+OO ND-147 7.86E+03 8.56E+03 5.13E+02 O.OOE+OO 5.02E+03 3.72E+05 1.82E+05 O.OOE+OO PM-147 9.20E+05 8.80E+04 3.60E+04 O.OOE+OO 1.68E+05 9.12E+05 4.70E+04 O.OOE+OO PM-148m 1.06E+05 2.68E+04 2.10E+04 O.OOE+OO 4.06E+04 2.56E+06 3.28E+05 O.OOE+OO PM-148 4.35E+03 7.10E+02 3.58E+02 O.OOE+OO 1.28E+03 5.22E+05 4.91 E+05 O.OOE+OO PM-149 3.93E+02 5.51 E+01 2.27E+01 O.OOE+OO 1.05E+02 9.92E+04 2.23E+05 O.OOE+OO PM-151 9.60E+01 1.59E+01 8.08E+OO O.OOE+OO 2.86E+01 4.52E+04 1.82E+05 O.OOE+OO SM-151 8.56E+05 1.68E+05 3.89E+04 O.OOE+OO 1.82E+05 6.14E+05 2.82E+04 O.OOE+OO 11.4-129 LASALLE ODCM PART II SECTION 4.doc

Table 4-31 (Page 4 of 4)

Teen Inhalation Ri mrem*m3/yr*µCi CY-LA-170-301 Revision 8 June 2016 Part II, Offsite Dose Calculation Manual Nuclide Bone Liver T Body Thyroid Kidney Lung Gl-LLI Skin SM-153 1.94E+02 1.61 E+02 1.18E+01 O.OOE+OO 5.25E+01 5.69E+04 1.42E+05 O.OOE+OO EU-152 2.37E+06 5.75E+05 5.04E+05 O.OOE+OO 2.67E+06 4.01E+06 1.08E+05 O.OOE+OO EU-154 7.54E+06 9.84E+05 6.88E+05 O.OOE+OO 4.35E+06 7.30E+06 2.67E+05 O.OOE+OO EU-155 1.60E+06 1.57E+05 9.68E+04 O.OOE+OO 6.12E+05 1.21E+07 4.78E+05 O.OOE+OO EU-156 2.16E+04 1.62E+04 2.64E+03 O.OOE+OO 1.09E+04 1.10E+06 3.65E+05 O.OOE+OO TB-160 2.43E+05 O.OOE+OO 3.03E+04 O.OOE+OO 9.60E+04 3.18E+06 2.08E+05 O.OOE+OO H0-166m 3.52E+06 1.25E+06 7.90E+05 O.OOE+OO 1.60E+06 4.99E+06 1.34E+05 O.OOE+OO W-181 7.12E+01 2.30E+01 2.41E+OO O.OOE+OO O.OOE+OO 2.36E+04 2.15E+03 O.OOE+OO W-185 2.22E+03 7.34E+02 7.78E+01 O.OOE+OO O.OOE+OO 7.68E+05 9.12E+04 O.OOE+OO W-187 1.20E+01 9.76E+OO 3.43E+OO O.OOE+OO O.OOE+OO 4.74E+04 1.77E+05 O.OOE+OO NP-239 3.38E+02 3.19E+01 1.77E+01 O.OOE+OO 1.00E+02 6.49E+04 1.32E+05 O.OOE+OO U-232 5.85E+08 O.OOE+OO 4.18E+07 O.OOE+OO 6.35E+07 3.07E+09 3.57E+05 O.OOE+OO U-233 1.24E+08 O.OOE+OO 7.54E+06 O.OOE+OO 2.90E+07 7.34E+08 3.30E+05 O.OOE+OO U-234 1.18E+08 O.OOE+OO 7.38E+06 O.OOE+OO 2.84E+07 7.19E+08 3.23E+05 O.OOE+OO U-235 1.14E+08 O.OOE+OO 6.94E+06 O.OOE+OO 2.67E+07 6.75E+08 4.10E+05 O.OOE+OO U-236 1.14E+08 O.OOE+OO 7.09E+06 O.OOE+OO 2.73E+07 6.90E+08 3.03E+05 O.OOE+OO U-237 4.20E+02 O.OOE+OO 1.12E+02 O.OOE+OO 1.73E+03 1.41E+05 1.03E+05 O.OOE+OO U-238 1.09E+08 O.OOE+OO 6.48E+06 O.OOE+OO 2.50E+07 6.31 E+08 2.90E+05 O.OOE+OO NP-237 1.31E+10 8.48E+09 5.77E+08 O.OOE+OO 4.28E+09 7.19E+08 4.18E+05 O.OOE+OO NP-238 3.38E+03 8.16E+02 5.27E+01 O.OOE+OO 3.10E+02 1.40E+05 1.90E+05 O.OOE+OO PU-238 1.20E+10 8.24E+09 5.78E+08 O.OOE+OO 2.48E+09 2.50E+09 3.83E+05 O.OOE+OO PU-239 1.38E+10 8.96E+09 6.44E+08 O.OOE+OO 2. 75E+09 2.34E+09 3.50E+05 O.OOE+OO PU-240 1.38E+10 8.96E+09 6.43E+08 O.OOE+OO 2.74E+09 2.34E+09 3.57E+05 O.OOE+OO PU-241 2.99E+08 7.65E+07 1.12E+07 O.OOE+OO 5.18E+07 2.08E+06 7.34E+03 O.OOE+OO PU-242 1.28E+10 8.64E+09 6.20E+08 O.OOE+OO 2.65E+09 2.26E+09 3.43E+05 O.OOE+OO PU-244 1.50E+10 9.92E+09 7.10E+08 O.OOE+OO 3.03E+09 2.58E+09 5.11E+05 O.OOE+OO AM-241 1.42E+10 9.60E+09 5.68E+08 O.OOE+OO 4.26E+09 8.40E+08 3.90E+05 O.OOE+OO AM-242m 1.43E+10 9.04E+09 5.72E+08 O.OOE+OO 4.24E+09 3.37E+08 4.91E+05 O.OOE+OO AM-243 1.42E+10 9.36E+09 5.56E+08 O.OOE+OO 4.17E+09 7.93E+08 4.58E+05 O.OOE+OO CM-242 2.54E+08 2.01 E+08 1.13E+07 O.OOE+OO 5.12E+07 5.41 E+08 4.17E+05 O.OOE+OO CM-243 9.52E+09 6.64E+09 4.00E+08 O.OOE+OO 1.87E+09 8. 72E+08 4.1 OE+05 O.OOE+OO CM-244 7.35E+09 5.22E+09 3.10E+08 O.OOE+OO 1.45E+09 8.40E+08 3.97E+05 O.OOE+OO CM-245 1.46E+10 9.76E+09 6.02E+08 O.OOE+OO 2.82E+09 8.08E+08 3.70E+05 O.OOE+OO CM-246 1.45E+10 9.76E+09 6.02E+08 O.OOE+OO 2.81 E+09 8.24E+08 3.63E+05 O.OOE+OO CM-247 1.42E+10 9.52E+09 5.93E+08 O.OOE+OO 2.77E+09 8.08E+08 4.78E+05 O.OOE+OO CM-248 1.18E+11 7.86E+10 4.89E+09 O.OOE+OO 2.28E+10 6.66E+09 7.70E+06 O.OOE+OO CF-252 5.73E+09 O.OOE+OO 2.46E+08 O.OOE+OO O.OOE+OO 2.74E+09 1.51 E+06 O.OOE+OO 11.4-130 LASALLE ODCM PART II SECTION 4.doc