APPLICANT: ___

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SRO/ADMIN-1 Rev. 1

Rev. 0 New JPM.

Rev. 1 Integrate validation comments Rev. 1 Page 2 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure SRO/ADMIN-1 Task

Title:

Perform review of completed Surveillance Test.

Task Number: 210.003 Perform the initial review of a completed STP.

KIA

Reference:

2.1.7 (4.7)

Method of Testing:

Simulated Performance: D Classroom: ~

Read to the examinee:

Actual Performance: ~

Simulator: D Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-1 is in Mode 1 with normal electrical and system lineups.
2. Bay temperature is 72°F.
3. U-1 Control Room Operator just completed STP 0-73C-1 "Component Cooling Pump Quarterly Test" on 11 Component Cooling Pump as scheduled surveillance.
4. You are performing the duties of the U-1 Unit Supervisor.

Initiating Cue:

You are directed to perform the Acceptance Criteria for the completed STP IA W Step 6.1.AB.

Task Standard:

This JPM is complete when STP 0-73C-1 Acceptance Criteria is completed correctly and any required actions identified.

Rev. 1 Page 3 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

Required Materials:

1. Prepared STP 0-73C-1
2. U-1 Tech Specs General

References:

1. WC-AA-111 (EN4-104 replacement)

Time critical task:

No Validation Time:

10 minutes Setup:

1. None Rev. 1 Page 4 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded = CRITICAL STEP)

TIME START: ----

CUE:

Provide the Operator with the prepared STP 0-73C-1.

CUE:

Inform Operator that Sect. 6.1 was completed and requires SRO review of Acceptance Criteria.

0 Step 6.1.AB.1 Was 11 CC Pump corrected L\\P between 33.2 and 40.5 PSID in step 6.1.N?

0 Step 6.1.AB.2 Were 11 CC PP INBD AND OUTBD bearing vibration readings less than the ACTION RANGE limit as recorded in Step 6.1.N?

1--------------------~

0 Step 6.1.AB.3 Was CC Flow greater than or equal to 5160 GPM in step 6.1.R?

0 Step 6.1.AB.4 IF 1-CC-115 is being tested for full stroke closed, THEN perform the following.

D Step 6.1.AB.4.a Was 11 CC Pump reverse rotation absent in step 6.1.V?

0 Step 6.1.AB.4.b Was 12 or 13 CC Pump flow greater than or equal to 5160 GPM in step 6.1.U?

0 Step 6.1.AB.5 This test section is considered satisfactory if YES or NI A was answered in all steps above.

Determines the following:

Inboard vertical vibration is greater than ALERT RANGE but less than ACTION RANGE.

All other vibration readings are in spec.

Circles YES and initials step 6.1.AB.2.

Determines step is applicable.

Determines the following:

No reverse rotation noted.

Circles YES and initials step 6.1.AB.4.a Determines the following:

Flow was > 5160 GPM.

Circles YES and initials step 6.1.AB.4.b Rev. 1 Page 5 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

If asked, the 13 CC pump is electrically aligned to 14 480V bus (normal alignment).

CUE:

When operator notifies SM of the inoperable equipment, acknowledge report, ask for recommendation.

If candidate asks to review WC-AA-111, supply him with attached copy.

D Step 6.1.AB.5.a IF unsat, THEN notify SM, declare the affected equipment inoperable and take actions as required by administrative actions stated in WC-AA-111 (NIA if NOT UNSAT).

References WC-AA-111.

(candidate should note that shifting 13 CC pump to 11 480V bus would allow exiting the LCO)

CUE:

When CRO directed to write Condition Report for failed pump flow, acknowledge direction.

0 Step 6.1.AB.5.b Initiate a Condition Report for any equipment deficiencies (NIA if NO equipment deficiencies).

Initials ste.

CUE:

When CRO directed to write Condition Report for vibration in Alert Range, acknowledge direction.

D Step 6.1.AB.5.c Initiate a Condition Report for components tested in this section that exceeded the ALERT RANGE to evaluate pump conditions and include the need to be placed in the Supplemental Program for increased testing frequency. (NIA if NO components tested in this section exceeded the ALERT RANGE).

Initials step Rev. 1 Page 6 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded = CRITICAL STEP)

CUE:

When CRO directed to call the IST Engineer for vibration in Alert Range, acknowledge direction.

D Step 6.1.AB.5.c.(l)

Inform the IST Engineer of any components Directs CRO to call /or state intention to that exceed the ALERT RANGE.

(Voicemail is Acceptable).

call IST Engineer.

  • Initials step.

(NIA ifNO components in this section exceed the ALERT Range).

TERMINATING CUE: This JPM is complete when Sect 6.1 of STP-73C-l is completed. The evaluator is expected to end the JPM.

TIME STOP:

Rev. 1 Page 7 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SRO/ADMIN-1 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): -----------------------~

Applicant Response:


~

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 1 Page 8 of9

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. Unit-1 is in Mode 1 with normal electrical and system lineups.
2. Bay temperature is 72°F.

Form ES-C-1

3. U-1 Control Room Operator just completed STP 0-73C-1 "Component Cooling Pump Quarterly Test" on 11 Component Cooling Pump as scheduled surveillance.
4. You are performing the duties of the U-1 Unit Supervisor.

Initiating Cue:

You are directed to perform the Acceptance Criteria for the completed STP IA W Step 6.1.AB.

Rev. 1 Page 9 of9

I.... - - - - - - - - - - - - - - - - -.

APPLICANT: ----

CALVERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SRO/ADMIN-2 Rev. 2

Rev I Modified & updated JPM to 2017 Format using revised procedures.

Rev. 2 Integrated validation comments.

Rev. 2 Page 2 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure SRO/ADMIN-2 Task

Title:

Verify an Estimated Critical Condition Calculation Task Number: 202.247 KIA

Reference:

2.1.25 (4.2)

Method of Testing:

Simulated Performance: IZI Classroom: IZI Read to the examinee:

Actual Performance: IZI Simulator: D Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-2 is in MODE 3 at normal operating temperature and pressure. Current time is 0800.
2. The reactor tripped while performing RPS testing 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br /> ago. Preparations are underway for a quick trip recovery startup to begin within the next 30 minutes with criticality anticipated in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> at 1 Oam.
3. The following conditions exist:
a. Unit-2 tripped from 100% power 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br /> ago.
b. Power history: Prior to the trip, Unit-2 operated at 100% for the previous 68 days.
c. Burnup from the plant computer point "CEBURNUP" is 14,500 MWD/MTU.
d. Nuclear Fuels has provided a Xenon Worth Calculation and a B-10 Correction factor of 0.971.
4. An ECC has been prepared by an extra licensed operator.

Initiating Cue:

The Shift Manager has directed you to Verify the Estimated Critical Condition calculation per NEOP-302 Section 4 of Attachment 2, Step 6.3.2.

Verify the ECC's from 0800 to 1200.

Task Standard:

Correctly identify all errors on prepared ECC and provides correct data to replace errors.

Rev.2 Page 3 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

Required Materials:

1. Procedures and manuals normally available in the plant General

References:

1. NEOP302, Estimated Critical Condition
2. NEOP-23, Technical Data Book (Unit-2)

Time critical task:

No Validation Time:

30 minutes Setup:

1. None Rev. 2 Page 4 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: ----

D Locates NEOP-302 Step 6.3.2 D 6.3.2 Submit Section 2 to a licensed SRO for review. Prior to performing the review, the SRO shall review Step 4.5.2 D Step 4.5.2 Some calculations performed in this procedure are originated by Reactor Engineering (RE) and then reviewed by a Senior Reactor Operator (SRO).........

D Step 4.5.2.1 Verify that the previous critical condition is correct if not previously reviewed D Step 4.5.2.2 INDEPENDENTLY VERIFY that all recorded data and calculations in the section being reviewed are accurate D Step 4.5.2.3 VERIFY that the ECC Upper and Lower Bounds are calculated correctly AND the established bounds are between 135 inches withdrawn on Reg Grp 5 and Zero Power PDIL, if reviewing an estimated critical condition.

STANDARD (shaded= CRITICAL STEP)

Same as Element Same as Element Same as Element Determines previous critical condition was previously reviewed by an SRO as shown by SRO signature on Attachment 2 Section 1 Identifies following errors:

1100 Lower Bound Gp 4 level 1100 Upper Bound Gp 4 & Gp5 level 1200 Lower Bound Gp 3 <ZPDIL Rev. 2 Page 5 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded = CRITICAL STEP)

CUE:

When student instructs preparer to make necessary corrections to Attachment 2 Section 4, tell him to determine and document corrections on a blank line on form.

CJ Step 4.5.2.4 IF an error is found, THEN INSTRUCT the preparer to make the necessary corrections, AND REPEAT the review TERMINATING CUE: This JPM is complete when corrected values are inserted into blank line on Attachment 2 Section 4. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev. 2 Page 6 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SRO/ADMIN-2 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: _______________________ _

Result:

SAT UNSAT Examiner's Signature and Date: --------------------

Rev. 2 Page 7of8

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET Form ES-C-1

5. Unit-2 is in MODE 3 at normal operating temperature and pressure. Current time is 0800.
6. The reactor tripped while performing RPS testing 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br /> ago. Preparations are underway for a quick trip recovery startup to begin within the next 30 minutes with criticality anticipated in 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> at 1 Oarn.
7. The following conditions exist:
a. Unit-2 tripped from 100% power 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br /> ago.
b. Power history: Prior to the trip, Unit-2 operated at 100% for the previous 68 days.
c. Bumup from the plant computer point "CEBURNUP" is 14,500 MWD/MTU.
d. Nuclear Fuels has provided a Xenon Worth Calculation and a B-10 Correction factor of 0.971.
8. An ECC has been prepared by an extra licensed operator.

Initiating Cue:

The Shift Manager has directed you to Verify the Estimated Critical Condition calculation per NEOP-302 Section 4 of Attachment 2, Step 6.3.2.

Verify the ECC's from 0800 to 1200..

Rev. 2 Page 8of8

ESTIMATED CRITICAL CONDITION, Critical Conditions Worksheet Sequence # 37 Unit: --'2o;;__ __

Cycle: _l.L SECTION 1 - Input Data A.

Date I Time of Subcriticality:

Date:

2/09/17

/Time:

B.

Cycle Burnup:

14500 MWD/MTU C.

Excess Reactivity:

9.443

%"'1p D.

HZP IBW:

118.882 ppm/%"'1p E.

B-10 Correction Factor:

0.971 F.

Corrected HZP IBW (=DIE):

122.432 ppm/%L'ip G.

Target CEA Position:

Gp 5:

0

/Gp 4:

90 H.

Target CEA Position Worth:

.565

%1'.\\p Performed By (RE):

Reviewed By (SRO):

SECTION 2 - Target RCS Boron Concentration 0000 NEOP-302 Revision 00901 Page 1 of 21 Page 1 of 4

/Gp 3:

135 Date:

To-cW.y Date:

To-cW.y Criticality Hours Xenon Boron Worth Target Critical After Worth at [L] (%1'.\\p)

Boron (ppm)

Prep.

Rev.

Target Shutdown at [K]

[M]

[N]

lnit.

I nit.

Date/Time

[K]

(%1'.\\p)

=C-L-H

= M x F (RE)

(SRO)

[J]

=J-A

[L]

2110/17 1000 34 1.120 7.758 949.8 NOTE: This table may be revisited and appended as necessary.

ESTIMATED CRITICAL CONDITION, Critical Conditions Worksheet Sequence # 37 SECTION 3 - Actual RCS Boron Concentration Adjustment NUlt:

NEOP-302 Revision 00901 Page 2 of 21 Page 2 of 4 Following the boration/dilution of the RCS to the target boron concentration [N], the actual achieved RCS boron

[P] is determined by measured grab sample. If dilution was used to achieve actual RCS boron, [Q] is copied from [E]; if boration was used, the actual B-10 correction factor [Q] is recalculated using Step 6.2.3.1.b and included with this attachment.

P.

Actual RCS Boron:

930 ppm Q.

Actual B-10 Correction Factor:

.971 R.

Actual Corrected HZP IBW (=DI Q):

122.432 ppm/o/o~p S.

Actual Boron Worth (=PI R):

7.59

%~p Performed By (RE):

Date:

Todcty Reviewed By (SRO):

Date:

Todcty

30 hrs 31 hrs 32 hrs 33 hrs 34 hrs 35 hrs 36 hrs 37 hrs 38 hrs 39 hrs 40 hrs Xenon Report (Units for all entries %~p)

Variable [T]

1.415 1.341 1.267 1.192 1.120 1.054 0.987 0.923 0.860 0.795 0.731 Prepared by

~ffA.el,~E~~~-

~----------

Date Io-day_

Independently Reviewed by

.~<9~filhift~' ~S~R<9~------

Date Io-day_

ESTIMATED CRITICAL CONDITION, Critical Conditions Worksheet Sequence# 37 SECTION 4 - Estimated Critical Conditions Hrs.

Xenon CEA Worth Gp 5 I Gp 4 I Gp 3 Lower l.;t:A tsound Worth

(%~p)

= u + 0.5%~p Date Time After

(%~p)

[U]

from NEOP-13(23)

Gp 5 I Gp 4 I Gp 3 S/D

[T]

=C-T-S (in. w/d)

%~p (in. w/d)

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

2110/2017 0800 32 1.267

.586 0 I 87 / 135 1.086 0/22.5/ 112.5 2110/2017 0900 33 1.192

.661 0 /76.5 / 135 1.161 0 / 16.5 / 106.5 2110/2017 1000 34 1.120

.733 0/66.0/135 1.233 0 / 10.5 / 100.5 2/10/2017 1100 35 1.052

.815 0 / 54.0 /135 1.315 0 / 1.5 I 91.5 2/10/2017 1200 36 0.987

.866 0 / 45.75 / 135 1.366 0 I 0 I 85.5 I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I NOTE: This table may be revisited and appended as necessary Upper CEA Bouna

= u -0.5%~p Gp 5 I Gp 4 I Gp 3

%~p (in. w/d)

I I

I I

I I

I I

I I

I I

I I

.086 103.5 / 135 / 135

.161 81.75 / 135 / 135

.233 48.75 / 135 / 135

.315 28.51118.5 / 135

.366 22.5/112.5/135 I

I I

I I

I I

I I

I I

I I

I NEOP-302 Revision 00901 Page 20 of 21 Page 3 of 4 Prep.

Rev.

lnit.

lnit.

(RE)

(SRO)

ESTIMATED CRITICAL CONDITION Hrs.

Date Time After SID 2/10/2017 0800 32 1.267

.586 211012017 0900 33 1.192

.661 211012017 1000 34 1.120

.733 211012017 1100 35 1.052 211012017 1200 36 0.987 Correct 211012017 1100 35 1.052

.799, Critical Conditions Worksheet Sequence # 37 SECTION 4 - Estimated Critical Conditions Gp 5 I Gp 4 / Gp 3 from NEOP-13(23)

(in. w/d)

I %L1p I

KEY 0 I 87 I 135 1.086 0 I 22.5 I 112.5 0176.5 I 135 1.161 0 I 16.5 I 106.5 0166.0 I 135 1.233 0 I 10.5 I 100.5 I

I 0 I 56.25 /135 1.299 0 I 3.75 I 93.0 I

I I

I NOTE: This table may be revisited and appended as necessary

%L1p

.086

.161

.233

.299 103.5 I 135 I 135 81.75I135I135 48.75 I 135 I 135 I

30.0 I 120 I 135 I

NEOP-302 Revision 00901 Page 20 of 21 Prep.

lnit.

(RE)

Page 3 of 4 Rev.

lnit.

(SRO)

APPLICANT: ___

CALVERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SRO/ADMIN-3 Rev

Rev 1 Revised 2011 NRC ADMIN-3 to new format, using latest procedures Rev.2 Integrated validation comments.

Rev. 2 Page 2of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure SRO/ADMIN-3 Task

Title:

Establish initial plant conditions for and approve performance of an STP.

Task Number: 210.001 KIA

Reference:

2.2.40 (4.7)

Method of Testing:

Simulated Performance: D Classroom: ~

Read to the examinee:

Actual Performance:~

Simulator: D Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1)

Unit-1 is at 100% reactor power.

2)

STP 0-8A-1 is scheduled today.

3)

Ops FSTC has indicated that monthly and quarterly surveillances are due.

4)

No maintenance was performed on the lA DG.

5)

STP M-651C-1A is not required.

6)

All D/G's are operable and available.

7)

Plan of the Day (POD) has Slow Speed Start of lA DG listed.

8)

You are performing the duties of the CRS.

Initiating Cue:

1)

The Shift Manager directs you to prepare STP 0-8A-l for performance by completing SRO portions of step 4.0.A Task Standard:

This JPM is complete when the SRO portion of the STP preliminary section is properly completed (IA W criteria contained in critical steps) using the given information and Technical Specifications.

Rev. 2 Page 3of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

Required Materials:

1. Blank copy of STP 0-8A-1 General

References:

1. U-1 Tech Specs Time critical task:

No Validation Time:

30 minutes Setup:

1. None Rev. 2 Page 4of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

TIME START: ----

CUE:

The Shift Manager directs you to prepare STP 0-8A-l for performance by completing SRO portions of up through section 4.0.

D Step 4.0.A. l IF STP M-651C-1A is to be performed concurrently with this test THEN NOTIFY E&C to perform STP M-651C-1A prerequisites.

NOTE Determines this step is N/ A from given cues and either writes N/ A with initial or just initials the block.

SIAS A-10 Logic, Channel Functional test is required quarterly in Modes 1-3.

D Step 4.0.A.2 INDICATE ESFAS test requirements:

D SIAS/UV test required:

(check required tests) 0 PERFORM Sect. 6.4, QUARTERLY SIAS A-10 LOGIC AND UV-4 LOGIC TEST.

  • Required if performing STP M-651C-1A.

0 ESF AS testing NOT required:

D LEA VE Sections 6.4 through 6.6 blank.

NOTE Taking IA DG to LOCAL makes the DG inoperable. This minimizes unloaded run time during ESF AS testing AND is the preferred alignment.

Rev. 2 Page 5of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT 0 Step 4.0A.3 IF performing ESF AS testing, THEN REVIEW equipment availability AND INDICATE IA DG alignment during test:

(NIA if NOT testing ESFAS) 0 lA DG in LOCAL during ESF AS test:

  • LEA VE Sections 6.2 AND 6.3 Blank.

0 lA DG in AUTO during ESFAS test:

  • Required if performing STP M-651C-IA 0 LEA VE Sections 6.5 AND 6.6 blank NOTE ST AND ARD (shaded = CRITICAL STEP)
  • Student checks the lA DG in LOCAL during ESF AS test: box.

Student initials the step.

Student leaves the lA DG in AUTO during ESF AS test: box blank.

IA DG remains operable when performing a Slow Speed start from IC18A.

0 Step 4.0.A.4 REVIEW PMT requirements, Surveillance Schedule AND INDICATE lA DG start requirements:

Slow start of lA DG:

Required if performing STP M-65IC-1A.

LEA VE Sections 6.2 AND 6.5 blank.

IF lA DG will be LOCAL during ESF AS testing, THEN LEA VE Section 6.3 blank.

IF 1 A DG will be started before ESF AS testing, THEN LEA VE Section 6.6 blank.

Rev. 2 Page 6of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT Emergency start of lA DG:

LEA VE Sections 6.3 AND 6.6 blank:

IF 1 A DG will be in LOCAL during ESF AS testing, THEN LEA VE Section 6.2 blank.

Start of lA DG NOT required:

LEA VE Sections 6.2, 6.3, AND 6.5 through 6.7 blank:

D Step 4.0.A.5 REVIEW the Surveillance Schedule OR PMT to determine if Section 6.1 is required to be performed.

D YES - Performance of Sect 6.1 is required D

Monthly FO TRANSFER PP Automatic Start test is required.

D Quarterly IST FO TRANSFER PP Performance Capacity test is required.

D NO-Performance is NOT required; LEA VE Sect. 6.1 blank.

D Step 4.0.A.6 REVIEW the Surveillance Schedule OR PMT to determine if Section 6.8 is required to be performed.

D YES - Performance of Sect. 6.8 is required.

D NO - Performance is NOT required; LEA VE Sect.6.8 blank.

ST AND ARD (shaded= CRITICAL STEP)

Student leaves the Emergency start of lA DG: box blank.

Student leaves the Start of lA DG NOT required: box blank.

Student leaves the Performance is NOT required; LEA VE Sect. 6.1 blank box blank Student leaves the Performance is NOT required; LEAVE Sect.6.8 blank box blank Rev. 2 Page 7of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT D Step 4.0.A. 7 IF this the first performance of this test after EDG-13 has been performed on 1 A DG, THEN INDICATE minimum lA DG loaded run time for Sect. 6. 7.

(NIA if NOT first test after EDG-13)

D 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> minimum loaded run time.

D 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> minimum loaded run time.

D Step 4.0.A.8 REVIEW the Surveillance Schedule OR PMT to determine if the Quarterly air receiver check valve testing is required.

D YES - Quarterly air receiver check valve testing is required.

D NO - Quarterly air receiver check valve testing is NOT required.

ST AND ARD (shaded = CRITICAL STEP)

Determines this step is NI A from given cues and either writes NI A with initial or just initials the block.

TERMINATING CUE: This JPM is complete when all SRO steps are complete in Sect. 4.0.A The evaluator is expected to end the JPM.

TIME STOP: __

Rev. 2 Page 8of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SRO/ADMIN-3 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ---------------~

Time to Complete:

Follow up Question(s): ______________________ _

Applicant Response:------------------------

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 2 Page 9of10

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1) Unit-I is at 100% reactor power.
2)

STP 0-8A-I is scheduled today.

Form ES-C-I

3)

Ops FSTC has indicated that monthly and quarterly surveillances are due.

4)

No maintenance was performed on the 1 A DG.

5)

STP M-65IC-IA is not required.

6)

All D/G's are operable and available.

7)

Plan of the Day (POD) has Slow Speed Start of IA DG listed.

8)

You are performing the duties of the CRS.

Initiating Cue:

I) The Shift Manager directs you to prepare STP 0-8A-I for performance by completing SRO portions of step 4.0.A.

Rev. 2 Page 10of10

APPLICANT: ----

CALVERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SRO/ADMIN-4 Rev. 1

Rev. 0 New JPM.

Rev. 1 Integrated validation comments.

Rev. 1 Page 2 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure SRO/ADMIN-4 Task

Title:

Review and approve a gaseous waste discharge permit.

Task Number: None KIA

Reference:

2.3.11 (4.3)

Method of Testing:

Simulated Performance: D Classroom: ~

Read to the examinee:

Actual Performance: ~

Simulator: D Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1)

Unit-1 is at 100% reactor power, Unit-2 is defueled.

2)

Discharge of 13 WGDT is scheduled for today.

3)

Access Control Area Ventilation is secured due to U-2 Main Exhaust fans being secured.

4)

You are performing the duties of the CRS.

Initiating Cue:

1)

The Shift Manager directs you to review and approve the gaseous waste discharge permit.

Task Standard:

This JPM is complete when the gaseous waste discharge permit is reviewed and identifies wrong unit for discharge and that the discharge, once started must be secured due to high radiation.

Rev. 1 Page 3 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

Required Materials:

1. Prepared gaseous waste permits
2. Prepared copy of 0 I-17B
3. List of plant conditions General

References:

1. OI-17B Waste Gas System
2. OI-22A Main Exhaust Fan System Time critical task:

No Validation Time:

15 minutes Setup:

1. None Rev. 1 Page 4 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

TIME START:

CUE:

The Shift Manager directs you to review and approve the gaseous waste discharge permit.

If candidate asks for Attachment 2, tell him "CRO has Attachment 2 and will log RMS readings".

D Gaseous Waste Permit OPERATIONS AUTHORIZATION AND RELEASE DATA SECTION Shift Manager/SRO Release Criteria Reviewed (Note 5).

D Note 5 The Shift Manager/SRO review signature acknowledges that the release criteria required is understood and that required plant systems are in operation AND required plant configuration for conducting the release has been established.

Reviews Note 5.

Reviews Gaseous Waste Discharge Permit Notes setpoints for Rad Monitor alarms are identified.

Contacts Chemistry directly or directs Chemistry to be contacted to change the permit for discharge to U-1 Main Vent.

CUE:

When candidate calls Chemistry to change permit for U-1 Main Vent Fans, acknowledge request and give candidate the corrected permit.

D Note 5 The Shift Manager/SRO review signature acknowledges that the release criteria required is understood and that required plant systems are in operation AND required plant configuration for conducting the release has been established.

Reviews Gaseous Waste Discharge Permit Notes setpoints for Rad Monitor alarms are identified.

Rev. 1 Page 5 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

When candidate signs the permit as complete, initial and date permit to complete the OPERATION AUTHORIZATION AND RELEASE DATA SECTION.

CUE:

Inform candidate that the discharge is now in progress IA W Ol-17B, once the candidate finds the correct section of OI-17B hand give him the signed off section and give him the attached parameter page and ask if any new actions are required.

D OI-17B Sect. 6.4 NOTE above step 6.4.B.19 D If at any time during the release the RMS Critical Setpoint is exceeded, the release should IMMEDIATELY be SECURED and Plant Chemistry contacted Reviews the parameters given and recognizes that Main Vent RMS RI-5415 has exceeded the critical alarm setpoint.

Contacts Chemistry directly or directs Chemistry to be contacted regarding the exceeding of Main Vent RMS critical setpoint.

TERMINATING CUE: This JPM is complete when candidate determines the discharge should be terminated. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev. 1 Page 6 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SRO/ADMIN-4 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: -------------------------

Result:

SAT UNSAT Examiner's Signature and Date: ---------------------

Rev. 1 Page7of9

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1)

Unit-1 is at 100% reactor power, Unit-2 is defueled.

2)

Discharge of 13 WGDT is scheduled for today.

Form ES-C-1

3)

Access Control Area Ventilation is secured due to U-2 Main Exhaust fans being secured.

4)

You are performing the duties of the CRS.

Initiating Cue:

1)

The Shift Manager directs you to review and approve the gaseous waste discharge permit.

Rev. 1 Page 8 of9

13 W GDT discharge data 13 WGDT Pressure 75 psig Discharge flow rate 48 scfm RI-2191 OOS U-1 WRNGM 7.0E2 µCi/sec U-1 Main Vent RMS 5.15E02 cpm Gaseous Waste Discharge Filter 5.0 inches of water Rev. 1 Page 9of9

APPLICANT: ----

CALVERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM SRO/ADMIN-5 Rev. 2

Rev 1 Revised 2011 NRC ADMIN-5 to new format, using latest procedures.

Rev 2 Integrated validation comments.

Rev. 2 Page 2of12

Appendix C Job Performance Measure Worksheet Form ES-C-I Facility: Calvert Cliffs I & 2 Job Performance Measure SRO/ADMIN-5 Task

Title:

Determine Appropriate Emergency Response Actions.

Task Number: 204.097 Determine appropriate emergency response actions per the ERPIP while maintaining an overview of plant conditions.

KIA

Reference:

2.4.38 (4.4)

Method of Testing:

Simulated Performance: D Classroom: ~

Read to the examinee:

Actual Performance: ~

Simulator: D Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-I was at IOO% power with IA DG tagged out and OC DG pre-aligned to I 1 4KV bus IAW OI-2IA-1.
2. Security has reported a credible threat to CCNPP from the FBI.
3. Severe thunderstorms in progress with wind gusts of 50 mph.
4. A loss of offsite power has occurred resulting in a reactor trip.
5. lB DG failed to start on the undervoltage condition; subsequent attempts to start the lB DG have been unsuccessful.
6. CRO completed the Vital Auxiliaries Safety Function and reported it as complete to the Unit Supervisor 5 minutes after the trip.
7. You are performing the duties of the Shift Manager.
8. This JPM is TIME CRITICAL.

Initiating Cue:

You have been requested to determine appropriate Emergency Response Actions, per the ERPIP, based on the current plant conditions provided.

Task Standard:

Determines EAL classification, and correctly completes the initial notification form within prescribed time limits.

Rev. 2 Page 3of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in the Control Room Time critical task:

Yes Validation Time:

12 minutes Setup:

1. None Rev. 2 Page 4of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

EVALUATOR NOTE:

The "EAL CLOCK" starts after candidate reads "Initial Conditions" CUE sheet.

CUE: I Inform candidate that all initial conditions just occurred at time now.

TIME START:

EAL CLOCK TIME START:

0 Identify and locate Shift Manager Candidate locates Shift Manager Checklist Checklist.

from provided book.

0 1.1 - Entry into the Emergency Plan.

0 1.1.1 - Print your name and today's date.

Candidate correctly prints name and current date on checklist.

CUE: I Inform candidate that you will be acting as Shift Communicator and Dose Assessor.

0 1.1.2 - Call or direct an available Candidate calls, or directs you to call Shift individual to call the Shift Communicator and Dose Assessor to the Communicator and Dose Assessor to the Control Room.

Control Room.

NOTE:

The following step is applicable only to those Units that have implemented FLEX 0

1.1.3 - If SAFER FLEX equipment is deemed necessary, then DIRECT that the Nuclear Duty Officer be contacted at Determines step is NOT applicable.

(630) 657-2202 and DIRECT SAFER response organization activation.

0 1.1.4 - If SAFER FLEX equipment is deemed necessary, then REFER to Determines step is NOT applicable.

Sections 2.5 and 3.3 for additional actions.

0 1.2 - Emergency Classification and PAR and Notifications.

NOTE:

Emergency Classification and declaration shall be completed as soon as possible but no later than 15 minutes from the time indications an EAL threshold being met or exceeded are available in the Control Room.

Rev.2 Page 5of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

Inform candidate that U-2 US will perform Attachment 24 "SECURITY" 0

0 1.2.1 - If entry is due to a security event, THEN perform the appropriate actions in the station specific procedure in parallel with completing this checklist.

1.2.2 - Classify the events in progress using EP-CE-111, Emergency Classification and Protective Action Recommendations.

Determines step is applicable.

Directs U-2 US to perform Attachment 24 "SECURITY" Reference Tab 2, EAL Wall Chart.

Evaluator Note Examinee should review the EAL Wall Chart and determine SAl.1 and determine Tab 2 is NOT necessary at this time since no Protective Action Recommendations required.

0 Determining if one or more EAL thresholds in the EAL matrix have been matched or exceeded.

0 Classifying the event at the highest level emergency classification for which an EAL is currently being met or exceeded.

Note: Unit was in a Station Blackout for a couple of minutes but Initial Conditions given clearly state OC DG was aligned to 11 4KV bus in <5 min.

Evaluator Note: Student should move back to previous procedure to complete following steps.

CUE:

0 When a Peer Check of the EAL call is requested, acknowledge the request.

1.2.2.A - IF time permits, THEN validate the emergency classification with the ST A (peer check), if available.

Requests Peer Check from ST A.

Rev. 2 Page 6of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT D

1.2.2.B - Declare the event by announcing the following:

"I am declaring a(n)

(EAL) at (time) due to ----

(brief reason) and assuming the role as Emergency Director.

D 1.2.3 - DETERMINE if protective actions for onsite personnel are necessary using EP-AA-113-F-53, Onsite Protective Measures Flowchart.

STANDARD (shaded= CRITICAL STEP)

Fills out checklist:

References Tab 3 (EP-AA-113-F-53) and determines flowchart calls for "Consider Implementing protected area Evacuation and Accountability".

CUE:

IF Operator elects to perform PA Announcements, acknowledge that the Unit Supervisor will perform the announcements per EP-AA-112-F-57.

0 I.2.4 -ANNOUNCE, or DIRECT PA announcements, for station personnel as necessary.

0 1.2.5 - DETERMINE the appropriate PAR Operator will not perform per CUE provided.

per EP-CE-111, Emergency Classification Determines step is NOT applicable.

and Protective Action Recommendations.

D 1.3 Notifications for Change in Classification or PAR D

0 D

1.3.1 - If the classification is an Unusual Event, then COMPLETE ERO notification/activation per EP-AA-112-100-F-57, ERONS Notification Details.

1.3.2-GINNA Only...

1.3.3 - If the classification is an Alert or higher and the ERO has not been activated, then DIRECT activation per EP-AA-112-100-F-57 (Tab 5)

Determines step is NOT applicable.

Determines step is NOT applicable.

Determines step is applicable Rev.2 Page 7of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

Evaluator Note: Student should move to Tab 5 to complete following steps 0

1 - INITIATE PRIMARY ACTIVATION OF NOTIFICATION SYSTEM USING THE INTERNET 0

1.1 - CIRCLE the appropriate station from the table below.

D 1.2 - CIRCLE the appropriate Activation/Termination for the event from the table below.

Evaluator Note: Student should move back to previous procedure to complete following steps.

CUE:

0 1.3.3.A-NMPOnly...

Determines step is NOT applicable.

Ensure student knows you are performing the duties of the Emergency Communicator, acknowledge order to notify ERO.

D 1.3.3.B - PROVIDE completed ERONS form to the shift communicator and DIRECT them to notify/activate ERO.

D 1.3.1. C - If no one is available to notify ERO.....

NOTE:

Hands the Tab 5 (EP-AA-112-100-F-57) to the Emergency Communicator and directs notification of the ERO.

Determines step is NOT applicable.

Notifications to the state and local are required within 15 minutes of Emergency Declaration or a change in PAR.

D 1.3.4 State and Local Notification.

D 1.3.4.A - COMPLETE station specific notification form Tab 7.

Determines step is applicable.

Rev. 2 Page 8of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

Evaluator Note: Student should move to Tab 7 to complete following steps D

CCNPP INITIAL NOTIFICATION FORM D

A.l D

A.2 D

A.3 D

A.4 D

A.5 D

A.5.a D

A.5.b D

A.6 Protective Action Recommendations D

A.6.a D

A.7 D

Shift ED/Corporate ED Name:

Radioactivity released is /was monitored NIA Type of Release NIA Prints name and signs form.

Rev. 2 Page 9of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

Evaluator Note: Student should move back to previous procedure to complete following steps.

CUE:

CUE:

0 1.3.4.A.1 -GINNA Only...

Determines step is NOT applicable.

When a Peer Check of the EAL call is requested, acknowledge the request.

0 1.3.4.B - If time permits, then OBTAIN a peer check of completed Requests Peer Check from STA.

form information.

Ensure student knows you are performing the duties of the Emergency Communicator; acknowledge order to notify State and Local.

0 1.3.4.C - PROVIDE completed form to Shift Communication and

  • DIRECT them to notify State and Local.

Hands the Tab 7 (Initial Notification Form) to the Emergency Communicator and directs notification of State and Local.

TERMINATING CUE: The JPM is complete when an EAL classification is determined and declared within time requirements and the Initial Notification form is completed and given to the communicator within time requirements. No further actions are required. The operator is expected to end the JPM.

TIME STOP: ---

Rev. 2 Page 10of12

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SRO/ADMIN-5 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: -------------------------

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 2 Page 11of12

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET Form ES-C-1

1. Unit-I was at 100% power with lA DG tagged out and OC DG pre-aligned to 11 4KV bus IA W OI-21A-l.
2. Security has reported a credible threat to CCNPP from the FBI.
3. Severe thunderstorms in progress with wind gusts of 50mph.
4. A loss of off site power has occurred resulting in a reactor trip.
5. 1 B DG failed to start on the undervoltage condition; subsequent attempts to start the 1 B DG have been unsuccessful.
6. CRO completed the Vital Auxiliaries Safety Function and reported it as complete to the Unit Supervisor 5 minutes after the trip.
7. You are performing the duties of the Shift Manager.
8. This JPM is TIME CRITICAL.

Initiating Cue:

You have been requested to determine appropriate Emergency Response Actions, per the ERP IP, based on the current plant conditions provided.

Rev. 2 Page 12of12

APPLICANT: ___

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SIMULATOR-I Rev. 2

Rev. 0 Rev I Rev2 New JPM.

Incorporate comments from validations Incorporate comments from NRC Rev.2 Page 2of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-1 (Alt Path)

Task

Title:

Dropped CEA during startup.

Task Number: 055.003 Operate the Regulating CEAs 202.008 Respond to CEA(s) misaligned by >15" KIA

Reference:

001.A2.03 (3.5,4.2)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: r8J Simulator: r8J Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. U-1 is currently performing a startup IA W OP-2 Section 6. 7
2. Critical data was just taken with power at :::::1 x 104 %.
3. You are performing the duties of the Reactor Operator.

Initiating Cue:

You have been directed to raise reactor power to ::::: 1 % power IA W OP-2 Step 6. 7.S Task Standard:

Continues startup IA W OP-2 Step 6.7.S, establishes stable SUR <ldpm, and then takes proper corrective actions for a dropped CEA IAW AOP-lB.

Rev. 2 Page 3of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room Time critical task:

No Validation Time:

2S minutes Setup:

1. Reset simulator to IC-271 U-1 critical approximately lE-4% Power MOC
2. Ensure CEDS is Off
3. CEAPDS selected to display all CEAs
4. Event Trigger 1 P 1 COS _PWRJIOO 1 _MT >.001 (WRNI Power reaches 1 E-2%)

S. CEA 6 drop ceds012_06 on Event 1

6. 1 COS D40 L TON to On at time zero
7. Place NRRHOl & NRRH02 on trend on plant computer screen near ICOS Rev. 2 Page 4of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: ----

D OP-2 Section 6.7 TAKE THE REACTOR CRITICAL STANDARD (shaded= CRITICAL STEP)

CAUTION Do NOT exceed a sustained one DPM startup rate D

S - Raise Reactor power to approximately 1 % by LRNI AND PERFORM the following:

1. CHECK ALL WRNI channels indicating less than 2%.

D OI-42 Sect. 6.7 REGULATING CEA OPERATION When raising power by withdrawing Regulating CEA' s sustained startup rate does not exceed 1 DPM.

CUE:

If asked by candidate if Chemistry has been informed, tell them this notification has already been completed.

D B.1 - IF CEAs are inserted less than 130 inches. THEN INFORM Chemistry to ensure requirements of CP-204, SPECIFICATION AND SURVEILLANCE PRIMARY SYSTEMS, related to C0-58 are met.

NOTE Either asks US (Unit Supervisor) if this has already been done or calls Chemistry directly.

If any CEA is moved greater than 7.5 inches in modes 1 or 2, then within one hour TS SR 3.1.4.1 should be performed.

D D

B.2 - ENSURE desired regulating group (1,2,3,4,5) is selected.

B.3 - Ensure the desired CEA in the group is selected.

NOTE Ensures Group 4 is selected.

Any CEA in Group 4 can be selected.

Rev. 2 Page 5of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT ST AND ARD (shaded = CRITICAL STEP)

To prevent challenging CEA interlocks, Manual Sequential should not be used for CEA withdrawal ifthe CEAs are in an abnormal alignment for ASI control PER Section 6.16, ASI CONTROL USING REGULATING CEAs (i.e. groups 1,2 and/or 3 partially inserted), until the associated groups are at the upper computer stop.

CUE:

If candidate asks US (Unit Supervisor) if Manual Sequential or Manual Group should be used, ask the applicant his recommendation, then direct candidate to perform step as recommended.

0 B.4 - SELECT AND DEPRESS one of the following mode control pushbuttons:

MANUAL SEQUENTIAL MANUAL GROUP MANUAL INDIVIDUAL 0

B.5 - IF necessary to bypass CMI, THEN REFER to Section 6.8, USE OF Determines step is NOT Applicable CEA MOTION INHIBIT BYPASS.

NOTE Group sequencing must be accomplished by the Reactor Operator when Plant Computer, OR DAS Bis OOS....

Unit-1 CEA-18 will NOT move whilejumpered PER ECP-15-000409.

CAUTION RAISE/HOLD/LOWER switch operation should be accomplished with positive...

Withdraw and insert CEAs only in a deliberate and carefully controlled manner...

Primary plant anomalies caused by second lant transients are rarel, if ever,...

0 B.6 - INSERT OR WITHDRAW selected CEA(s) using the RAISE/HOLD/LOWER switch while observing the following limits.

Rev. 2 Page 6of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 D

D ELEMENT D

a. - IF withdrawing CEA(s) in Manual Group OR Manual Sequential Mode, THEN STOP withdrawal at Upper Computer Stop OR a maximum height of 130.5 inches when computer is NOT available.

D

b. - IF inserting CEA(s) in Manual Group OR Manual Sequential Mode, THEN STOP insertion at Lower Computer Stop or a minimum height of 6.0 inches when computer is NOT available.

B. 7 - ENSURE at least 5 seconds has elapsed once CEA motion is completed.

B.8 - IF other CEA manipulations are desired, THEN REPEAT steps 1 through 7.

D OP-2.6.7.S - Raise Reactor power to approximately 1 % by LRNI AND PERFORM the following:

1. CHECK ALL WRNI channels indicating less than 2%.

STANDARD (shaded = CRITICAL STEP)

Determines step is NOT Applicable.

Determines step is NOT Applicable.

After stopping CEA motion candidate should ensure at least 5 seconds has elapsed before movement initiated again.

Candidate may or may not use additional CEA movements to achieve desired SUR.

CUE:

Once a stable SUR is achieved and power is rising toward 1 % the dropped CEA malfunction will be entered. Once the candidate recognizes and announces the dropped CEA to Control Room, ask the candidate to recommend a course of action and direct candidate to perform action recommended.

BEGIN ALTERNATE PATH D

AOP-lB IV.A-CONTROL CEA MOVEMENT AND STABILIZE THE UNIT D

A. I - IF the CEAs are moving without operator action, THEN ensure the CEDS Determines step is NOT Applicable.

Control System is turned off.

Rev. 2 Page 7of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CAUTION If CEA misalignment causes power to be reduced, power shall not be raised until the CEA is within it alignment requirements or until Reactor Engineering is consulted.

CAUTION Do NOT use CEAs to control RCS temperature.

CUE:

Inform candidate that the CRO will perform this step.

0 A.2 - Maintain Tcold on programmed value by performing ANY of the following actions as applicable:

0 Adjust Turbine Load 0

Adjust TBV s or ADV s 0

Initiate boration 0

A.3 - Verify Pressurizer pressure is between 2225 and 2275 psia, and trending toward 2250 psia.

0 A.4 - Verify position of ALL CEAs using reed switch position indication.

Requests CRO to perform this step.

(No change in temperature is expected since below POAH).

Verifies pressure is ~2250 psia.

Verifies all CEAs using CEAPDS indication. Recognizes only 1 CEA is misaligned.

CUE:

IF NRRHO 1 & NRRH02 trends are not working use pointer to indicate that reactivity is negative on these trend screen to reinforce that reactor is subcritical.

0 A.5 - IF the CEA malfunction causes a critical reactor to become subcritical, THEN perform the following:

CAUTION The affected CEA(s) should not be inserted/withdrawn until ALL unaffected Regulating CEAs are inserted.

0 A.5.a-Fully insert ALL unaffected Regulating CEAs.

0 01-42 Sect. 6.7 REGULATING CEA OPERATION Refers to OI-42 Section 6.7 REGULATING CEA OPERATION or properly performs all steps necessary to insert Regulating CEAs.

Rev. 2 Page 8of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

If asked by candidate if Chemistry has been informed, tell them this notification has already been completed.

0 B.1 - IF CEAs are inserted less than 130 inches. THEN INFORM Chemistry to ensure requirements of CP-204, SPECIFICATION AND SURVEILLANCE PRIMARY SYSTEMS, related to C0-58 are met.

NOTE Either asks US if this has already been done or calls Chemistry directly.

If any CEA is moved greater than 7.5 inches in modes 1 or 2, then within one hour TS SR 3.1.4.1 should be performed.

0 0

B.2 - ENSURE desired regulating group

( 1,2,3,4,5) is selected.

B.3 - Ensure the desired CEA in the group is selected.

NOTE Ensures Group 4 is selected.

Any CEA in Group 4 can be selected.

To prevent challenging CEA interlocks, Manual Sequential should not be used for CEA withdrawal ifthe CEAs are in an abnormal alignment for ASI control PER Section 6.16, ASI CONTROL USING REGULATING CEAs (i.e. groups 1,2 and/or 3 partially inserted), until the associated froups are at the upper computer stop.

CUE:

If candidate asks US (Unit Supervisor) if Manual Sequential or Manual Group should be used, ask the applicant his recommendation, then direct candidate to perform step as recommended.

0 B.4 - SELECT AND DEPRESS one of the following mode control pushbuttons:

MANUAL SEQUENTIAL MANUAL GROUP MANUAL INDIVIDUAL 0

B.5 - IF necessary to bypass CMI, THEN REFER to Section 6.8, USE OF Determines step is applicable.

CEA MOTION INHIBIT BYPASS.

Rev. 2 Page 9of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP) 0 OI-42 Section 6.8 USE OF CEA MOTION INHIBIT (CMI) BYPASS.

NOTE D

CMI MAY be bypassed to more than one CEA group at a time.

D Steps 1 and 2 will bypass CMI to selected group and apply CMI to all other groups.

0 CEA MOTION INHIBIT BYPASS annunciator on 1 (2)C05 will alarm.

D B.1 - DEPRESS GROUP BYPASS pushbutton(s) on CEDS Control Panel for the CEA groups(s) needing alignment.

0 B.2 - DEPRESS AND HOLD MOTION INHIBIT BYPASS pushbutton on CEDS Control Panel.

D B.3 - WHEN at least 5 seconds have elapsed, THEN INITIATE group OR Individual CEA Motion.

Waits at least 5 seconds before inserting Regulating CEAs.

D OI-42 Section 6.7 REGULATING CEA OPERATION NOTE Group sequencing must be accomplished by the Reactor Operator when Plant Computer, OR DAS Bis OOS....

Unit-1 CEA-18 will NOT move whilejumpered PER ECP-15-000409.

CAUTION RAISE/HOLD/LOWER switch operation should be accomplished with positive...

Withdraw and insert CEAs only in a deliberate and carefully controlled manner...

Primary plant anomalies caused by secondary plant transients are rarely, if ever,...

Rev. 2 Page 10of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

Once CEA insertion has begun the evaluator can terminate the JPM.

0 B.6 - INSERT OR WITHDRAW selected CEA( s) using the RAISE/HOLD/LOWER switch while observing the following limits.

TERMINATING CUE: The JPM is complete when Regulating CEAs are being inserted to comply with AOP-IB. No further actions are required. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev.2 Page 11of13

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULATOR-1 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: -----------------------~

Result:

SAT UNSAT Examiner's Signature and Date:

Rev.2 Page 12of13

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. U-1 is currently performing a startup IA W OP-2 Section 6.7
2. Critical data was just taken with power at::::::} x 104 %.
3. You are performing the duties of the Reactor Operator.

Initiating Cue:

Form ES-C-1 You have been directed to raise reactor power to:::::: 1 % power IA W OP-2 Step 6.7.S Rev. 2 Page 13of13

APPLICANT: ___

CALVERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM SIMULATOR-2 Rev. 3

Rev. 1 Rev2 Rev 3 Update procedures since last given in 2011 Incorporate comments from validations.

Incorporate comments from NRC Rev. 3 Page 2 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Task

Title:

Override shut a PORV Job Performance Measure Sim-2 (Alt Path)

Task Number: 064.035 Override shut a PORV KIA

Reference:

002.A2.01 (4.3, 4.4)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: IZJ Simulator: IZJ Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit 1 is stable in Mode 4.
2. Temperature band of250°F +/-10° established and controlled by CRO.
3. Pressure band of 400 psia +/-10 psia established and controlled by RO.
4. All General Precautions and Initial Conditions are met.
5. You are performing duties of the Reactor Operator.

Initiating Cue:

The Unit Supervisor directs you to align Low Pressure Pressurizer control IA W OI-1 H Sect. 6.3.

Task Standard:

The candidate will diagnose that the PORV is open due to equipment malfunction and shut the associated PORV block valve and secure RCP's if required.

Rev.

Page 3 of

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room
2. ALM-1C06, RCS Control Alarm Manual
3. 0 I-1 H Pressurizer Pressure Control Time critical task:

No Validation Time:

10 minutes Setup:

1.

Reset to IC-275.

2.
3.
4.
5.

Override 1-PI-103-1to1533# (PIC06_1PI103 l_MT to 1533) on Event 1.

Override PORV 402 handswitch (P1C06_1HS1402) to "manopen on Event 1.

Override PORV HS not in auto alarm (P 1 C06 _ E23 _ L TON) to OFF at time zero.

Ensure PZR level deviation is <4".

6.
7.
8.
9.
10.

Insert PORV MPT keys 47 & 48 in panel.

Insert SIT outlet valve keys 25-28 in panel.

Insert PORV Block MOV keys 45 & 46 in panel.

Place all PZR Heaters in Off.

Place simulator in run when candidate is ready to start.

11. Initiate Event 1 when directed by the examiner.

Rev. 3 Page 4 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: ---

0 OI-lH Section 6.3 LOW PRESSURE PRESSURIZER CONTROL.

0 B.1 - IF controlling U-1 pressure, THEN PERFORM the following:

0

a. - ENSURE PRESSURIZER SPRAY VL V CONTROLLER, 1-HIC-100 is in MANUAL with zero output.

0

b. - CYCLE Pressurizer Heaters while lowering Pressurizer level to maintain pressure.

0

c. - CHECK deviation less than 4 inches between Pressurizer level and STANDARD (shaded= CRITICAL STEP)

Determines step is applicable.

Verifies that 1-HIC-100 is in manual with 0% or negative output.

No action required at this time due to current RCS pressure.

programmed setpoint using 1-L T-Checks deviation is <4".

1 lOX and 1-LT-1 lOY as read on PZR LVL recorder 1-LR-110.

0

d. - IF the deviation between Pressurizer level and Pressurizer programmed setpoint is greater than 4 inches...

0

e. - PLACE the selected Pressurizer Pressure Controller 11 PZR PRESS CONTR CHAN X, 1-PIC-lOOX OR 11 PZR PRESS CONTR CHAN Y, 1-PIC-lOOY, in MANUAL with 50% output signal.

Determines step is NOT applicable.

Rev. 3 Page 5 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT ST AND ARD (shaded = CRITICAL STEP)

NOTE IF Pressurizer Backup Heaters are used they will remain energized.

0 F. - PLACE one bank of Proportional Heaters in AUTO AND IF necessary to maintain Pressurizer pressure at the desired pressure, THEN PLACE the additional bank of Pressurizer Proportional Heaters in AUTO IF necessary to maintain Pressurizer pressure at the desired pressure, THEN PLACE additional banks of Pressurizer Backup Heaters in AUTO CUE:

Initiate Event 1 to cause faulted PORV It is acceptable to place additional bank of proportional heaters in AUTO and to place any B/U heater banks in AUTO if candidate feels this is necessary to control pressure.

BEGIN ALTERNATE PATH 0

Locates the 1 C06 alarm manual and refers to E-21.

0

1. - The PORVs are energized.

0

1. - PERFORM the following:

0

a. - IF reactor trip occurs, THEN IMPLEMENT EOP-0, Post-Trip Immediate Actions.

Locates 1 C06 ARM and refers to E-21.

The candidate determines the step is applicable since PORV 402 is open with red light lit.

The candidate determines the reactor is shut down and step is NOT applicable.

CUE: The shift manager will contact the electric shop.

0 D

D

b. - NOTIFY the electric shop to verify the trip status of the PORV thermal overloads to ensure PORV operability. [B0034]
c. - IF the PORVs are in NORMAL, THEN:...
d. - IF the PORVs are in MPT ENABLE, THEN:

Candidate informs US of step and is informed that the Shift Manager will call electric shop.

The candidate determines PORVs are in variable MPT and step is NOT applicable.

The candidate determines PORVs are in variable MPT and step is applicable.

Rev. 3 Page 6 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 CUE:

ELEMENT D (1) -TRIP any RCPs operating in the NON-OPERATING AREA of the RCP curve.

The candidate may perform step (2) since there is no actual high pressure condition, these actions will be unsuccessful in shutting the PORV.

D (2) - WHEN the cause of the high pressure condition has been corrected, THEN: [B0064]

D (3) - IF a PORV fails to shut or is open due to a failed transmitter, THEN SHUT the applicable PORV Block, 1-RC-403-MOV or 1-RC-405-MOV.

Candidate determines the PORV is open due to equipment malfunction and not high RCS pressure.

Determines step is NOT applicable.

CUE:

The CRO will perform step 1.d.(4).

D (4) - DRAIN the PORV discharge piping to the Quench Tank as follows:

US informs the candidate that the CRO will perform this step.

D

e. - MONITOR computer points T106, T107, and Tl OS for leak-off Candidate uses plant computer to monitor leak-off temperatures.

temperatures.

Terminating Cue: This JPM is complete when the candidate isolates the open PORV flow path. No further actions are required. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev. 3 Page 7 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULATOR-2 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): ______________________ _

Applicant Response: ________________________ _

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 3 Page 8 of9

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. Unit 1 is stable in Mode 4.
2. Temperature band of 250°F +/-10° established and controlled by CRO.
3. Pressure band of 400 psi a +/-10 psi a established and controlled by RO.
4. All General Precautions and Initial Conditions are met.
5. You are performing duties of the Reactor Operator.

Initiating Cue:

Form ES-C-1 The Unit Supervisor directs you to align Low Pressure Pressurizer control IA W 01-lH Sect. 6.3.

Rev. 3 Page 9 of9

APPLICANT: ----

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM SIMULATOR-3 Rev. 2

Rev.O Rev 1 Rev2 New JPM.

Incorporate comments from validation.

Incorporate comments from NRC.

Rev.2 Page 2of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-3 (Alt Path)

Task

Title:

Depressurize RCS to fill PZR in EOP-5.

Task Number: 202.015 Respond to RCS leakage exceeding capacity of one charging pump, modes 1 & 2.

KIA

Reference:

010.A4.01 (3.7,3.5)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: [8]

Simulator: [8]

Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-1 has experienced a LOCA from 100% power.
2. Unit-1 has tripped, EOP-0 has been completed and EOP-5 has been implemented.
3. You are performing the duties of the Reactor Operator.

Initiating Cue:

You have been directed to perform EOP-5 Step K and L. Maintain a subcooling band between 30 and 60 degrees.

Task Standard:

Initiate Aux Spray to depressurize RCS and throttle HPSI flow to control Pressurizer level.

Rev. 2 Page 3 oflO

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room Time critical task:

No Validation Time:

20 minutes Setup:

1. Reset simulator to IC-34 U-lat 100% Power MOC.
2. RCS leak of 700 gpm (rcs002 to 700gpm) at Time Zero.
3. Trip Reactor and complete EOP-0.
4. Ensure SIAS initiates.
5. Manually insert CIS with panel pushbuttons.
6. Secure all RCP's.
7. Control plant until subcooling ::::::50°F.
8. Ensure key 41 inserted in Aux Spray CV.
9. Ensure Key 20 inserted in 1-HS-2080A.
10. IC-272 will perform steps 1-7
11. Prepared to modify rcs002 to 10,000 gpm once throttling complete.

Rev.2 Page 4of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded = CRITICAL STEP)

TIME START:

D EOP-5 Step K DEPRESSURIZE THE RCS TO REDUCE SUBCOOLING AND MAINTAIN PRESSURIZER LEVEL NOTE If rapid pressure excursions due to RCS inventory or temperature changes have occurred, consider the RCS solid.

D 1 - IF a bubble exists in the Pressurizer OR the Reactor Vessel Head, THEN maintain subcooling as low as possible AND within the following limits:

  • Between 30 and 140° based on CET temperatures.
  • RCS pressure greater than the NPSH limits PER ATTACHMENT (1 ), RCS PRESSURE TEMPERATURE LIMITS.

D 1.a - Lower subcooling by ANY of the following methods:

D

( 1) - De-energize Pressurizer HTR(s).

D (2) - IF ALL RCPs are operating, THEN...

CUE: I CRO will control the cooldown rate.

D (3) - Lower the RCS cooldown rate.

D (4)- IF the overpressurization is due to HPSI/Charging flow AND HPSI throttle criteria are met...

Subcooling band of 30-60° subcooling, is given, critical task will only require maintaining between 30-140° subcooling per the procedure step.

Ensures all Pressurizer HTR( s) are de-energized.

Determines step is NOT applicable.

CRO will control the cooldown rate.

Determines step is NOT applicable.

Rev.2 Page 5of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

D (5)- Initiate AUX SPRAY as follows:

Determines step is applicable.

D (a) - Place the l-IA-2080-MOV CIS OVERRIDE switch, 1-HS-2080A, in OVERRIDE.

D (b)-Open the IA CNTMT ISOL valve, 1-IA-2080-MOV.

Places 1-HS-2080A in OVERRIDE.

Verifies 1-IA-2080-MOV is open.

CAUTION If the difference between the PZR WTR TEMP and CHG OUT TEMP is greater than 400°, then TRM 15.4.2 must be complied with.

CUE:

When directed by candidate to enter TRM 15.4.2, acknowledge report.

D ( c) - Record the following information:

PZR WTR TEMP (1-TI-101).

Records the temperatures and directs US to enter TRM 15.4.2.

CHG OUT TEMP (1-TI-229).

D (d)-Open the AUX SPRAY valve, l-CVC-517-CV.

0 (e)- Operate the LOOP CHG valves as necessary to adjust AUX SPRAY flow:

  • 1-CVC-518-CV
  • l-CVC-519-CV D (f) - Shift the PRESSURIZER SPRAY VL V CONTROLLER, Shifts 1-HIC-100 to Manual.

l-HIC-100, to MANUAL.

D (g) - Shut the PRZR SPRAY VL Vs by adjusting the output of 1-HIC-100 to 0%:

Places 1-HIC-100 output to 0%.

1-RC-1 OOE-CV 1-RC-lOOF-CV Rev.2 Page 6of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT D (h) - Maintain the pressurizer cooldown rate less than 200°F/hour.

ST AND ARD (shaded = CRITICAL STEP)

Monitors PZR cooldown rate to ensure

<200°F/hour.

CUE:

When HPSI throttling criteria is achieved the candidate should re-open Loop Chg valve(s) to slow the depressurization and prevent overfill of PZR. Step (e) above allows operation of these valves to control Aux Spray Flow.

0 EOP-5 Step LEV ALUA TE THE NEED FOR HPSI OR LPSI THROTTLING/TERMINATION 0

1. - IF HPSI PPs are operating AND ALL of the following conditions can be maintained:

At least 30° subcooling based on CET temperatures.

Pressurizer level greater than 101 inches { 141 }.

At least ONE S/G available for heat removal.

S/G level greater than (-) 170 inches.

Capable of being supplied with feed water.

Capable of being steamed.

Reactor Vessel level above the top of the hot leg.

THEN HPSI flow may be reduced by throttling the HPSI HDR valves, or stopping the HPSI PPs one at a time, as desired, to maintain the following:

RCS subcooling between 30 and l 40°F based on CET temperatures.

Pressurizer level between 101 inches

{ 141 } and 180 inches { 190}.

When all HPSI throttling criteria is met the candidate should secure 1 HPSI pump and shut 3 HPSI header valves and throttle the 4th to control subcooling and PZR level.

Other methods of throttling are acceptable as long as subcooling and PZR level are controlled.

Rev.2 Page 7of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

IF asked by candidate if stopping LPSI PPs is desired, then ask for a recommendation and direct his recommendation.

D

2. - IF pressurizer pressure is greater than 200 PSIA and constant OR rising, THEN the operating LPSI PPs may be stopped.

Candidate may or may not secure LPSI PPs.

When evaluator has determined that candidate has control of subcooling and PZR CUE:

level, direct simulator driver to increase RCS leak to 10,000 gpm.

IF CSAS actuates inform the candidate that the CRO will verify CSAS.

BEGIN ALTERNATE PATH D

3. - IF HPSI or LPSI throttle criteria can NOT be maintained after the pumps are throttled or secured, THEN restart the appropriate pumps AND restore full flow.

TERMINATING CUE: The JPM is complete when 11 & 13 HPSI, 11 & 12 LPSI are running and all 8 HPSI Header Valves are full open. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev.2 Page 8of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULA TOR-3 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: ------------------------~

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 2 Page 9of10

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. Unit-1 has experienced a LOCA from 100% power.

Form ES-C-1

2. Unit-1 has tripped, EOP-0 has been completed and EOP-5 has been implemented.
3. You are performing the duties of the Reactor Operator.

Initiating Cue:

You have been directed to perform EOP-5 Step K and L. Maintain a subcooling band between 30 and 60 degrees.

Rev. 2 Page 10of10

APPLICANT: ----

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SIMULATOR-4 Rev. 2

Rev.O Rev. 1 Rev. 1 New JPM.

Incorporate comments from validation.

Incorporate comments from NRC.

Rev. 2 Page 2of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-4 (Alt Path)

Task

Title:

Restore from loss of SRW Pump.

Task Number: 202.065 Respond to loss of Service Water in mode 1 or 2.

KIA

Reference:

076.A4.01 (2.9,2.9)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: ~

Simulator: ~

Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. U-1 is operating at 100% power MOC.
2. 11, 12, & 14 CAC Emergency Outlet Valves were opened for additional cooling.
3. All 3 SR W pumps are running due to summer seasonal high temperatures.
4. All General Precautions and Initial Conditions are met.
5. You are performing duties of Control Room Operator.

Initiating Cue:

You have been directed to restore Service Water to normal 2 pump lineup ( 11 & 12), now that temperatures have returned to normal IA W OI-15 Sect.6.2.B.10.

Task Standard:

Restore SR W System to normal lineup and upon loss of 11 SR W Pump restore a Service Water Pump to 11 header.

Rev. 2 Page 3of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room Time critical task:

No Validation Time:

15 minutes Setup:

1. Reset simulator to IC-34 U-1 at 100% Power MOC.
2. Open 11, 12, &14 CAC 8" Valvesl-SRW-1582-CV, 1585-CV, & 1593-CV.
3. Start 13 SR W Pump.
4. Loss of 11 SRW pump (srw003_01) on Event 1.
5. Shut 13 SRW pump to 12 SRW header valves (l-srw-119 & 1-srw-124) on Event 2.
6. Open 13 SRW pump to 11 SRW header valves ( 1-srw-117 & 1-srw-122 on Event 3.
7. Ensure orange tags hanging for 13 SR W PP aligned to 12 header.

Rev. 2 Page 4of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: ----

0 OI-15 Section 6.2 NORMAL OPERATIONS D

B.10. - WHEN additional cooling is NOT STANDARD (shaded= CRITICAL STEP) required, THEN restore system to normal Determines step is appliocable.

as follows:

D B.2.1 O.a - SHUT valves that were opened in step 5.a D

B.10.b-IF running, THEN stop the third SRWPP.

CUE:

Once 13 SR W pump is secured initiate Event 1 to trip 11 Service Water Pump.

Direct candidate to diagnose cause of alarm.

Direct candidate to recommend procedure, including proper section.

BEGIN ALTERNATE PATH D

1C13 alarm Window K-04 11 SR W HDR PRESS LO and K15 SRW PPS SIAS BLOCKED AUTO START.

Candidate determines 11 SR W pump has tripped. Candidate recommends AOP-7B Section V MODES 1 OR 2.

CUE:

After candidate recommends AOP-7B, direct candidate to perform AOP-7B Section V.

When candidate startsSection V.A inform him that the RO will perform step A.

D A. - DETERMINE IF A REACTOR TRIP IS REQUIRED.

Candidate informed the RO will perform this section.

Rev. 2 Page 5of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP) 0 B-REDUCESRWHEATLOAD.

Determines this section is applicable.

NOTE Reducing Main Generator Reactive Load will reduce Main Generator heating CAUTION Reducing Reactive Load on Unit 1 may cause Unit 2 Main Generator or DG limits to be exceeded.

CAUTION Rapid changes in Main Generator Reactive Load require coordination with the SO-TSO to minimize Electric System perturbations and alarms.

CUE:

When candidate calls SO-TSO to request reducing VARS on U-1 grant permission to do so.

0 B.1 -IF the Main Generator is paralleled, THEN coordinate with the SO-TSO to reduce the Main Generator MV ARS to zero.

0 B.2 - IF lB DG is affected by loss of its associated SRW header, THEN with the SM/US permission, shutdown the DG Determines step is NOT applicable.

PER the appropriate procedure being used at the time of event initiation.

CUE:

When/If candidate suggests a power reduction PER OP-3, tell him it is not required at this time.

0 B.3 Commence power reduction PER OP-3, NORMAL POWER OPERATION, as required.

0 C -ATTEMPT TO RESTORE SRW FLOW.

0 C.1. -IF the loss ofSRW is due to a system leak or rupture, THEN PROCEED to step D (page 13 ).

Determines step is NOT applicable.

Determines step is NOT applicable.

(SRW Head tank levels normal)

Rev.2 Page 6of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 CUE:

CUE:

ELEMENT D C.2. - IF an operating SR W PP has failed, THEN perform the following actions.

STANDARD (shaded= CRITICAL STEP)

Determines step is applicable.

D

a. - Place the handswitch for the failed SRW pp in PULL TO LOCK.

Takes 11 SRW pp HS to PTL.

D

b. - IF a Saltwater header is removed from service, THEN PROCEED to step C.2.d (pagelO).

D

c. - IF the backup SR W PP is available, THEN ensure that the backup SRW PP is mechanically aligned to the affected header.

D c.l -IF 13 SRW PP needs to be ali ned to 11 SRW header,...

D (1)- Place the handswitch for 13 SRW PP in PULL TO LOCK.

Determines step is NOT applicable.

Determines step is applicable.

Determines step is applicable.

When candidate calls TBO to lock shut 12 SR W Header valves initiate Event 2 and inform candidate step is complete after 2 minute delay.

D (2)-Lock shut 13 SRW Suction and Discharge valves to 11 SRW Header.

1-SRW-119 1-SRW-120 1-SRW-123 1-SRW-124 Contacts the Turbine Building watch and directs locking shut 11 SR W Header valves.

When candidate calls TBO to lock open 11 SR W Header valves initiate Event 3 and inform candidate step is complete after 2 minute delay.

D (3)-Lock open 13 SRW Suction and Discharge valves to 11 SRW Header.

1-SRW-117 1-SRW-118 1-SRW-121 1-SRW-122 Contacts the Turbine Building watch and directs locking open 11 SR W Header valves.

Rev. 2 Page 7of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT 0

c.2-IF 13 SRW PP needs to be aligned to 12 SRW Header, THEN perform the following actions.

0

d. -IF 13 SRW PP is the backup SRW PP, AND POWER is NOT available to 13 SR W PP....

STANDARD (shaded= CRITICAL STEP)

Determines step is NOT applicable.

Determines step is NOT applicable.

CAUTION Starting a backup SRW PP without determining the cause of the failure could initiate a common mode failure 0

e. - Start the backup SR W PP 0

C.3 - IF the affected HDR PRESS is greater than or equal to 80 psig, THEN PROCEED to step C.7 (Page 12).

0 C.7 - WHEN BOTH HDR PRESSs are greater than 80 psig, AND component temperatures are stable or lowering, THEN restore plant systems to normal.

Determines step is applicable.

Candidate should check both board indications and the plant computer to verify temperatures are restoring.

TERMINATING CUE: The JPM is complete when 11 SRW header press is >80 psig and candidate is checking temperatures to be stable or lowering. No further actions are required.

The evaluator is expected to end the JPM.

TIME STOP: ---

Rev. 2 Page 8of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULATOR-4 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response:------------------------

Result:

SAT UNSAT Examiner's Signature and Date: -------------------- Rev. 2 Page 9of10

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. U-1 is operating at 100% power MOC.

Form ES-C-1

2. 11, 12, & 14 CAC Emergency Outlet Valves were opened for additional cooling.
3. All 3 SR W pumps are running due to summer seasonal high temperatures.
4. All General Precautions and Initial Conditions are met.
5. You are performing duties of Control Room Operator.

Initiating Cue:

You have been directed to restore Service Water to normal 2 pump lineup (11 & 12), now that temperatures have returned to normal IAW 01-15 Sect.6.2.B.10.

Rev. 2 Page 10of10

APPLICANT: ----

CALVERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM SIMULATOR-5 Rev. 3

Rev. 1 Rev. 2 Rev 3 Update procedures since last used in 2011.

Incorporate comments from validation.

Incorporate comments from NRC.

Rev. 3 Page 2 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-5 Task

Title:

Respond to a faulted SIG.

Task Number: 201.065 Identify, Isolate and Confirm the affected Steam Generator.

KIA

Reference:

035.A2.01 (4.5,4.6)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: ~

Simulator: ~

Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. U-1 was operating at 100% power MOC.
2. A plant transient and manual Reactor trip occurred 20 minutes ago.
3. EOP-4 has been implemented.
4.

11 SIG has been isolated IA W Step H 1 & 2.

5. You are performing the duties of the extra Licensed Operator.

Initiating Cue:

The CRS directs you to verify the most affected SIG was isolated IA W EOP-4 Step H.3.

Task Standard:

Determines wrong SIG was isolated, restores feeding and steaming to 11 SIG, and isolates 12 SIG.

Rev. 3 Page 3 of9

Appendix C Job Performance Measure Worksheet Form ES-C-I Evaluation Criteria:

I. All critical steps completed (denoted by shading).

2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room Time critical task:

No Validation Time:

15 minutes Setup:

1. Reset simulator to IC-34 U-I at I 00% Power MOC.
2. Place an off-normal pink ring next to the 'I I Steam Generator' sign (under 11 S/G level safety channels).
3. Enter following malfunctions at time zero:

a)

MS010_02 IO% leak, I2 Steam generator rupture in containment.

b)

AFW006-0I, Failure of AFAS block.

c)

AFW006-02, Failure of AF AS block.

d)

AFW006-03, Failure of AF AS block.

e)

AFW006-04, Failure of AF AS block.

4. Place simulator in Run.
5. When containment pressure high pre-trip alarm actuates, manually trip the unit.
6. Stop all RCPs.
7. Isolate Letdown.
8. Insert malfunction to trip 13 AFW pump.
9. Isolate I I SIG per EOP-4 step H.
10. IC-273 performs I-9 Rev. 3 Page 4 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: -----

D H.3 - Verify the most affected SIG was isolated by checking the following:

SIG pressure lower for the affected SIG.

SIG level lowering for the affected SIG and stabilized for the unaffected SIG.

RCS loop Tcold lower in the affected loop.

D 3.1 - IF the wrong SIG was isolated, THEN perform the following actions:

STANDARD (shaded= CRITICAL STEP)

Determines step is applicable.

CAUTION Severe waterhammer may result if Main Feedwater is restored after it has been stopped for greater than 80 minutes.

CUE:

When candidate orders TBO to align 11 ADV control back to Control Room, wait 5 minutes then report complete.

D

a. - Restore feeding and steaming capability to the least affected S/G.

The candidate will at a minimum:

Restore Steaming:

I. Direct the TBO to transfer control of 11 ADV to the control room (Align 11 SIG Hand Transfer Valves to POSITION I) or direct manual operation.

Restore feeding:

l-AFW-4522-CV (13 AFW PP) l-AFW-4523-CV (13 AFW PP)

Rev. 3 Page 5 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 D

CUE:

ELEMENT STANDARD (shaded= CRITICAL STEP)

H.2 - Isolate the affected S/G.

D

a. - IF 11 S/G is the affected S/G, Determines step is NOT applicable.

THEN isolate 11 S/G by performing the following actions:

D

b. - IF 12 S/G is the affected S/G, THEN isolate 12 S/G by performing Determines step is applicable.

the following actions:

When candidate orders TBO to align 12 ADV control to 1C43, wait 5 minutes then report complete.

D (1) - Shut 12 ADV using the Hand Transfer Valves on the West wall of the Unit 1 45 ft Switchgear Room as follows:

(a) IF 12 ADV was locally operated, THEN remove the manual override.

(b) Verify 12 ADV controller, 1-HC-4056B, at 1 C43 is set at 0% output.

( c) Align 12 S/G Hand Transfer Valves to 1 C43 (POSITION 2):

1-HV-3939A

  • 1-HV-3939B D

(2) - Verify 12 SG FW ISOL valve 1-FW-4517-MOV, is shut.

D (3)- Verify 12 MSIV BYP valve, 1-MS-4052-MOV, is shut.

Candidate directs the TBO to 'Align 12 ADV to 1 C43 with a zero percent output' or similar.

The candidate may alternatively direct EOP-4 step numbers.

Verifies 1-FW-4517-MOV is shut.

(Valve may be shut at this point due to ESF AS actuations)

Verifies 1-MS-4052-MOV is shut.

Rev. 3 Page 6 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT 0

(4) - Shut 12 S/G BID valves:

1-BD-4012-CV l-BD-4013-CV 0

(5)- Shut 12 SG AFW STM SUPP

& BYPASS valves, 1-MS-4071-CV and l-MS-4071A-CV.

0

( 6) - Shut 12 S/G AFW BLOCK valves by placing the handswitches in SHUT:

0 0

l-AFW-4530-CV 1-AFW-4531-CV l-AFW-4532-CV l-AFW-4533-CV (7) - Shut the MS UPSTREAM DRN ISOL VL VS by placing handswitch 1-HS-6622 in CLOSE.

(8) - Observe locally, the S/G Safety Valves are NOT leaking.

Checks l-HS-6622 in close.

(valve closed from isolation of 11 S/G)

Candidate directs an operator to check for leaking S/G safety valves.

TERMINATING CUE: This JPM is complete when the operator determines the wrong S/G was isolated, restores feeding and steaming to 11 S/G, and isolates 12 S/G. The evaluator is expected to end this JPM.

TIME STOP: ---

Rev. 3 Page 7 of9

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULATOR-5 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response:


~

Result:

SAT UNSAT Examiner's Signature and Date:

Rev. 3 Page 8 of9

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. U-1 was operating at 100% power MOC.
2. A plant transient and manual Reactor trip occurred 20 minutes ago.
3. EOP-4 has been implemented.
4. 11 S/G has been isolated IA W Step H 1 & 2.
5. You are performing the duties of the extra Licensed Operator.

Initiating Cue:

Form ES-C-1 The CRS directs you to verify the most affected S/G was isolated IA W EOP-4 Step H.3.

Rev. 3 Page 9 of9

APPLICANT: ----

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM SIMULATOR-6 Rev. 1

Rev. 0 New JPM Rev. 1 Incorporated comments from validation.

Rev. 1 Page 2of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-6 Task

Title:

Shift 13 IRU Power Supply.

Task Number: 004.012 Transfer power supplies.

KIA

Reference:

027.A4.01 (3.3, 3.3)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance:~

Simulator: ~

Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit 1 is at 100 % power MOC.
2. Maintenance completed on breaker 52-1121, 13 IRU 1lB480V breaker.
3. All General Precautions and Initial Conditions are met.
4. You are performing duties as the Control Room Operator.

Initiating Cue:

The US directs shifting 13 IRU tol lB 480V bus IAW OI-5B Section 6.3 and perform a breaker operation check IA W OI-5B Section 6.1 as PMOT.

Task Standard:

The candidate will shift power supplies for 13 IRU, then start and stop 13 IRU.

Rev. 1 Page 3of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room Time critical task:

No Validation Time:

10 minutes Setup:

1.

Reset to IC-34

2.

Place simulator in run

3.

Ensure 13 IRU is aligned to 14B 480V bus.

Rev. 1 Page 4of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START: ---

0 OI-5B Section 6.3 SHIFTING 13 CONTAINMENT IODINE REMOVAL UNIT POWER SUPPLY FROM 14B 480V BUS TO 11 B 480V BUS.

STANDARD (shaded= CRITICAL STEP)

D Identifies correct section of procedure to use.

NOTE The preferred lineup for 13 CNTMT Iodine Removal Unit is 1 lB 480V Bus.

CUE:

Candidate should notify US to enter Tech Spec LCO 3.6.8. Acknowledge report and confirm entering TS.

D B.1. -IF plant is in Mode 1,2,3,4, THEN ENTER TS 3.6.8.

D B.2 - PLACE 13 IODINE FIL T FAN handswitch 1-HS-5297 in PULL-TO-LOCK at lClO, AND CHECK that "13 CNTMT FIL T SIAS BLOCK AUTO START" alarm is present on 1 C09 D B.3 - PLACE 14 BUS DISC IODINE FILT 13 keyswitch 1-HS-5297B in OPEN at lClO AND REMOVE key.

D B.4 - CHECK 14 BUS green light is off above 13 IODINE FILT FAN handswitch.

D B.5 -INSERT key from step 3 in 11 BUS DISC IODINE FILT 13 keyswitch 1-HS-5297A at lClO AND PLACE keyswitch to CLOSE.

D Notifies US to enter TS 3.6.8.

D Places 1-HS-5297 in PTL and checks alarm at 1 C09.

NOTE Fan handswitches spring return to "normal" from either START or STOP. The "normal" position is unmarked and lies between START and STOP on each handswitch.

Rev. I Page 5of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

D B.6-PLACE 13 IODINE FILT FAN handswitch in normal, AND CHECK the following:

  • "13 CNTMT FIL T SIAS D

Place 13 IRU Handswitch in normal BLOCKED AUTO START" and verifies alarm clears and green alarm is clear.

light is lit.

11 BUS green light is on above 13 IODINE FILT FAN handswitch.

D Does NOT exit TS 3.6.8 until after D B.7 -IF plant is in Mode 1,2,3,4, the breaker Op Check performed as THEN EXIT TS 3.6.8.

PMOT.

D OI-5B Section 6.1 MANUAL D

Identifies correct section of OPERATION OF CONTAINMENT procedure to use.

IODINE REMOVAL UNITS.

CAUTION Containment Iodine Removal Unit operation is undesirable whenever paint fumes are present in containment, due to the effect these have on the charcoal filters.

CUE:

IF candidate asks if any painting has taken place in containment tell him that U-1 has been at 100% power for past 3 months.

D B.1 - IF paint fumes are present from Minor Painting PER MN-3-100, D

Determines this step is NOT Safety Related and Controlled Protective Coatings, THEN applicable.

CONSIDER NOT running any Containment Iodine Removal Unit.

D B.2 - IF paint fumes are present from Major Painting PER MN-3-100, Safety Related and Controlled D

Determines this step is NOT Protective Coatings, THEN applicable.

DECLARE any Containment Iodine Removal Unit to be started inoperable, PER TS 3.6.8.

NOTE Fan handswitches spring return to "normal" from either START or STOP. The "normal" position is unmarked and lies between START and STOP on each handswitch.

Rev. 1 Page 6of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT D B.3 - MOMENTARILY PLACE handswitch for selected unit in START, AND ENSURE that it returns to normal when released:

13 IODINE FILT FAN (at lClO)...... l-HS-5297 D B.4 - CHECK that red light is on above selected fan handswitch (indicating that fan is energized).

D Checks red light is lit.

CUE:

When candidate prepares to log in service time to Charcoal Filter log inform candidate that extra licensed operator will take care of the logging requirement.

D B.5 - RECORD date and time filter was started in the Charcoal Filter Log for unit placed in service.

NOTE D

Candidate ensures date and time is logged in Charcoal Filter log.

Fan handswitches spring return to "normal" from either START or STOP. The "normal" position is unmarked and lies between START and STOP on each handswitch.

D C.1 - MOMENTARILY PLACE handswitch for selected unit in STOP, AND ENSUREthat it returns to normal when released:

13 IODINE FILT FAN (at lClO)...... l-HS-5297 D C.2 - CHECK that green light is on above selected fan handswitch.

(indicating that fan is de-energized).

D Checks green light is lit.

Rev. 1 Page 7of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

When candidate prepares to log in service time to Charcoal Filter log inform candidate that extra licensed operator will take care of the logging requirement.

D C.3 - RECORD date and time filter D

Candidate ensures date and time is was started in the Charcoal Filter Log logged in Charcoal Filter log.

for unit placed in service.

D C.4 - IF any units just secured were operated while paint fumes were D

Determines this step is NOT present from Major Painting, THEN DIRECT that charcoal filters be applicable.

tested PER TS 3.6.8 on any affected units.

CUE:

When notified to exit TS LCO 3.6.8 acknowledge the report D Exit TS LCO 3.6.8 once PMOT is D

Notify US to exit TS LCO 3.6.8 completed when PMOT completed SAT.

Terminating Cue: This JPM is complete when the candidate shifts power supply and performs breaker operation check for 13 IRU. The candidate is expected to end the JPM.

TIME STOP:

Rev. 1 Page 8of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULATOR-6 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): ______________________ _

Applicant Response: ________________________ _

Result:

SAT UNSAT Examiner's Signature and Date:


~

Rev. 1 Page 9of10

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. Unit 1 is at 100 % power MOC.

Form ES-C-1

2. Maintenance completed on breaker 52-1121, 13 IRU l lB 480V breaker.
3. All General Precautions and Initial Conditions are met.
4. You are performing duties as the Control Room Operator.

Initiating Cue:

The US directs shifting 13 IRU tol lB 480V bus IAW OI-5B Section 6.3 and perform a breaker operation check IA W OI-5B Section 6.1 as PMOT.

Rev. 1 Page 10of10

APPLICANT: ___

CALVERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM SIMULATOR-7 Rev. 2

Rev. 0 Rev. 1 Rev.2 NewJPM Incorporate comments from validation Incorporate comments from NRC.

Rev.2 Page 2of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Sim-7 Task

Title:

Energize a 480V Load Center.

Task Number: 005/006.002 Energize double ended load center from a service transformer.

KIA

Reference:

062.A4.01 (3.3, 3.1)

Method of Testing:

Simulated Performance: D Classroom: D Read to the examinee:

Actual Performance: fZ!

Simulator: fZ!

Plant: D I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit 1 is at 100 % MOC.
2. Maintenance/Testing completed on U440-13A.
3. 11 CEDM MG set is tagged out for maintenance.
4. General Precautions and Initial Conditions are met.
5. All required briefs have been performed.
6. You are performing duties as the Control Room Operator.

Initiating Cue:

The US directs energizing 13A 480V bus from its service transformer IA W appropriate procedures.

Task Standard:

The candidate will properly energize bus from its service transformer and open tie breaker.

Rev.2 Page 3of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Control Room
2. OI-27D-1 Station Power 480 Volt System Time critical task:

No Validation Time:

15 minutes Setup:

1.

Reset to IC-34.

2.

Place simulator in run.

3.

Shut 13A-13B Bus Tie Breaker using 1-CS-1312.

4.

Open 13A 480V Bus Feeder breaker using 1-CS-1301, with "off normal" pink ring on HIS.

5.

Open U440-13A 4KV feeder using 1-CS-152-1310, with "off normal" pink ring on HIS.

6.

Remote Function LOAD_ ON_ 11 to open at time zero.

Rev. 2 Page 4 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT TIME START:

D OI-27C Section 6.12 ENERGIZING A 4160/480/V TRANSFORMER.

D B.1 -Momentarily PLACE the 4160/480V transformer feeder breaker control switch in the CLOSE position.

STANDARD (shaded= CRITICAL STEP)

Identifies correct section of procedure to use.

CUE:

IF candidate calls TBO to check on transformer, report that transformer appears

normal, D B.2 - OBSERVE breaker CLOSED indication.

D OI-27D-1 Section 6.7 - ENERGIZING A DOUBLE ENDED LOAD CENTER FROM ITS ASSOCIATED SERVICE TRANSFORMER.

CAUTION Observes red light lit for breaker 152-1310.

Identifies correct section of procedure to use.

Attempts should NOT be made to re-energize a bus if a fault is suspected.

D B.1. - IF power is NOT available, THEN REFER to OI-27C, 4.16KV SYSTEM.

D B.2 - CHECK the associated transformer supply breaker is SHUT AND all alarms clear on that transformer.

D B.3 - CLOSE the normal feeder breaker with the control switch.

D B.4-VERIFY normal breaker closed indication.

NOTE Determines step is NOT applicable.

Checks breaker 152-1310, previously shut in OI-27C is shut.

Checks red light is on.

There are two bus tie breakers between Load Centers 15 and 25.

Rev. 2 Page 5 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT 0 B.5 - VERIFY OPEN the bus tie breaker(s).

0 B.6 - Verify potential indicating light is illuminated.

0 B.7 -IF bus voltage is NOT between 445 and 510 volts on each phase, THEN REFER to OI-28, OPERATION OF 500 KV SWITCHYARD.

NOTE Checks white light on.

Determines step is NOT applicable.

Total current drawn must be maintained less than 1200 amps.

CUE:

Inform candidate that no loads were shed when tying the busses and no Control Manipulation Form (now known as an Abnormal Component Position Sheet) was generated.

0 B.8 - RESTORE_loads which may have been shed while the Load Center was tied.

0 B.8.a - Close out the associated Control Manipulation Form.

Determines step is NOT applicable.

Determines step is NOT applicable.

Terminating Cue: This JPM is complete when the candidate energizes 13A 480V Bus from normal feed with tie breaker opened. The candidate is expected to end the JPM.

TIME STOP: ---

Rev.2 Page 6 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure SIMULA TOR-7 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: ________________________ _

Result:

SAT UNSAT Examiner's Signature and Date: ____________________ _

Rev. 2 Page 7 of8

Appendix C Initial Conditions:

1. Unit 1 is at 100 % MOC.

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

2. Maintenance/Testing completed on U440-13A.
3. 11 CEDM MG set is tagged out for maintenance.
4. General Precautions and Initial Conditions are met.
5. All required briefs have been performed.
6. You are performing duties as the Control Room Operator.

Initiating Cue:

Form ES-C-1 The US directs energizing 13A 480V bus from its service transformer IA W appropriate procedures.

Rev. 2 Page 8of8

~......-----------------.

APPLICANT: ----

CALVERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM Plant-1 Rev. 0

I Rev. 0 I New JPM.

Rev.O Page 2of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Plant-1 Task

Title:

Control Steam Flow from ADV's locally.

Task Number: 204.097 KIA

Reference:

039.A2.04 (3.4,3.7)

Method of Testing:

Simulated Performance: C8J Classroom: D Read to the examinee:

Actual Performance: D Simulator: D Plant: C8J I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-1 was at 100% power.
2. 11 Atmospheric Dump Valve has failed open.
3. Control Room staff has implemented AOP-7K Overcooling Event.
4. Manual operation of 1C03 ADV Controller did not shut the ADV.
5. You are performing the duties of an extra licensed operator.

Initiating Cue:

You have been directed to shut 11 ADV in controlled fashion from 1 C43 IA W AOP-7K, Step D.3, contact Control Room prior to any local operation.

Task Standard:

Correctly takes local control of 11 ADV and shuts it in a controlled manner as directed by the Control Room.

Rev. 0 Page 3 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Plant Time critical task:

No Validation Time:

15 minutes Setup:

1. None Rev.O Page 4 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT AOP-7K Overcooling Event.

D.3 -IF an ADV has failed, THEN perform ANY of the following as necessary.

D.3 1st Bullet - Shut any failed open ADV's by shifting ATMOSPHERIC STEAM DUMP CONT, 1-HIC-4056 to MANUAL and adjusting as necessary.

D.3 2nd Bullet - Locally shut the affected ADV isolation valve:

D.3 2nd Bullet - Shut the affected ADV from 1C43.

a. - IF 11 ADV is affected, THEN shut 11 ADV using the Hand Transfer Valves on the West wall of the U-1 45 ft Switchgear Room as follows:

STANDARD (shaded = CRITICAL STEP)

Determines step is NOT applicable.

(already performed by Control Room Staff).

Determines step is NOT applicable.

Determines step is applicable based on Initiating Cue.

Determines step is applicable.

CUE:

Control Room directs controller to be initially set at 100% during transfer allowing controlled shutting of 11 ADV.

When student simulates moving lever to right to raise output use a pointing device to show output rising.

a.l - Verify 11 ADV controller, 1-HC-4056A at 1C43 is set as necessary to perform a controlled recovery.

Rev.0 Page 5of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 CUE:

ELEMENT STANDARD (shaded= CRITICAL STEP)

When student simulates opening Hand Transfer box cover hand, show him a picture of the valves inside and have him simulate operation on the picture.

D a.2 - Align 11 S/G Hand Transfer Valves to 1C43 (Position 2).

1-HV-3938A 1-HV-3938B Control Room directs 11 ADV position of;:::66% initially.

CUE:

When student simulates moving lever to left to lower output use a pointing device to show output lowering.

D a.3 - Adjust 11 ADV controller, 1-HIC-4056A as necessary.

Control Room directs 11 ADV position of;:::33% after approx 30 seconds.

CUE:

When student simulates moving lever to left to lower output use a pointing device to show output lowering.

D a.3 - Adjust 11 ADV controller, 1-HIC-4056A as necessary.

Control Room directs 11 ADV position of 0% after approx 30 seconds.

CUE:

When student simulates moving lever to left to lower output use a pointing device to show output lowering.

D a.3 - Adjust 11 ADV controller, 1-HIC-4056A as necessary.

TERMINATING CUE: The JPM is complete when 11 ADV is shut. No further actions are required. The operator is expected to end the JPM.

TIME STOP: ---

Rev.O Page 6of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure IN-PLANT-1 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: -----------------

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response:-------------------------

Result:

SAT UNSAT Examiner's Signature and Date: ---------------------

Rev.O Page 7 of8

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET

1. Unit-I was at 100% power.
2. 11 Atmospheric Dump Valve has failed open.
3. Control Room staff has implemented AOP-7K Overcooling Event.
4. Manual operation of 1C03 ADV Controller did not shut the ADV.
5. You are performing the duties of an extra licensed operator.

Initiating Cue:

Form ES-C-1 You have been directed to shut 11 ADV in controlled fashion from 1 C43 IA W AOP-7K, Step D.3, contact Control Room prior to any local operation.

Rev. 0 Page 8 of8

APPLICANT: ___

CALVERT CLIFFS NUCLEAR POWER PLANT 2017NRC Initial Licensed Operator Exam JPM Plant-2 Rev. I

Rev. 0 New JPM.

Rev. 1 Integrate OTPS comments Rev. 1 Page 2 of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Plant-2 Task

Title:

Locally control AFW flow during EOP-7.

Task Number: 204.097 KIA

Reference:

E06 EAl.1 (4.0, 3.9)

Method of Testing:

Simulated Performance: IZ!

Classroom: 0 Read to the examinee:

Actual Performance: 0 Simulator: 0 Plant: IZ!

I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. Unit-2 was at 100% power.
2. A Station Blackout has occurred.
3. Control Room staff has implemented EOP-7 Station Blackout
4. 22 AFW Pump is running, supplying water to S/G's.
5. AFW flow control valves are beginning to fail open.
6. You are performing the duties of an extra licensed operator.

Initiating Cue:

You have been directed to locally control AFW flow IA W EOP-7 Step F.2.c.

Task Standard:

Correctly takes local control of22 AFW PP speed.

Rev. 1 Page 3of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Plant Time critical task:

No Validation Time:

15 minutes Setup:

I. None Rev. 1 Page 4of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

D EOP-7 Station Blackout NOTE:

The AFW Air Accumulators are designed for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of available air:

WARNING The use of N2 to operate AFW may result in the depletion of oxygen levels in some rooms due to system venting.

D F.2.c - When the S/G FLOW CONTR valves begin to fail OPEN, THEN align Liquid N2 System to supply SG FLOW CONTR valves by opening the following valves located in SRW Room.

CUE:

When candidate simulates opening O-N2-107, give feedback that handwheel rotates counter-clockwise until it stops.

CUE:

N2 SUPPLY TO U-2 AFW AMP AIR SYS B/U ISOLATION VAL VE, O-N2-107 (located SR W RM upper level, overhead of air amplifier).

AFW AMPLIFIER AIR SYSTEMN2 BACKUP SUPPLY VAL VE, 2-IA-390 (located SRW RM lower level, west of 21 SR W PP).

CUE:

Inform student he is the assigned operator.

D F.2.d-Assign an operator to locally control AFW discharge pressure locally Acknowledges he is the assigned operator.

as follows:

CUE:

When student contacts control room to establish communication, acknowledge that communication is established.

D d.(1 ). - Establish communications between the operator and the control room.

Verifies communications established with the control room.

Rev. 1 Page 5of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT 0

d.(2) - Isolate the Instrument Air to the Turbine Governor.

22AFWPP STANDARD (shaded= CRITICAL STEP)

CUE:

When candidate simulates shutting O-IA-509 & 510, give feedback that handwheel rotates clockwise until it stops.

2-AFW-3987 I/PA ISOL, 2-IA-509.

2-AFW-3987 I/PB ISOL, 2-IA-510.

CUE:

Filters are just upstream of the controllers, straight ahead after going in door. The filter drain is the small petcock on bottom of filter.

0 CUE:

0 When candidate simulates opening petcock, give feedback that handwheel rotates clockwise until it stops and air flow noise is heard, which slowly stops.

d.(3)- Open the filter drains on controllers to allow local control.

If student calls the control room for the S/G press and AFW PP discharge pressure then inform him S/G press is 870 psia and AFW discharge press is 1050 psia.

If student looks at gauges in AFW PP room then indicate 870 psia for S/G Press (Steam Inlet Press) and I 050 psia for AFW discharge pressure.

d.(4)-Adjust 22 AFW PP governor control knob to maintain discharge pressure at least 100 PSI greater than S/G pressure.

Student either locates the following gauges and recognizes >I 00 psia or asks control room for pressures:

22 AFW PP Discharge Pressure 2-MS-4502-PI S/G Pressure (Steam Inlet Press) 2-MS-3988-PI.

TERMINATING CUE: The JPM is complete when student has local control of 22 AFW PP speed and recognizes > 100 psid. The evaluator is expected to end the JPM.

TIME STOP: ---

Rev. 1 Page 6of8

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure IN-PLANT-2 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: _______________ _

Time to Complete:

Follow up Question(s): -----------------------

Applicant Response: ~----------------------~

Result:

SAT UNSAT Examiner's Signature and Date:

~-------------------

Rev. 1 Page 7 of8

Appendix C Job Performance Measure Worksheet EXAMINEE'S CUE SHEET Initial Conditions:

1. Unit-2 was at 100% power.
2. A Station Blackout has occurred.
3. Control Room staff has implemented EOP-7 Station Blackout
4. 22 AFW Pump is running, supplying water to S/G's.
5. AFW flow control valves are beginning to fail open.
6. You are performing the duties of an extra licensed operator.

Initiating Cue:

You have been directed to locally control AFW flow IAW EOP-7 Step F.2.c.

Form ES-C-1 Rev. 1 Page 8of8

APPLICANT: ___

CAL VERT CLIFFS NUCLEAR POWER PLANT 2017 NRC Initial Licensed Operator Exam JPM Plant-3 Rev. 2

Rev. 1 Updated with procedure changes since 2011 exam Rev. 2 Integrated OTPS comments Rev. 2 Page 2of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Facility: Calvert Cliffs 1 & 2 Job Performance Measure Plant-3 Task

Title:

Fill the SRW and CC head tanks during loss of AC power.

Task Number: 011.025, 015.008 KIA

Reference:

008.A4.07 (2.9, 2.9)

Method of Testing:

Simulated Performance: ~

Classroom: D Read to the examinee:

Actual Performance: D Simulator: D Plant: ~

I will explain the initial conditions, which steps to simulate or discuss, and provide initiating cues. When you complete the task successfully, the objective for this job performance measure will be satisfied.

Initial Conditions:

1. A severe fire has resulted in Control Room evacuation. AOP-9A has been implemented.
2. You are performing the duties of the Unit-2 ABO.

Initiating Cue:

You have just completed Step CH, ESTABLISH SALTWATER FLOW THROUGH THE COMPONENT COOLING HEAT EXCHANGERS which directs you to "Go to the 69' Aux Building to perform Step CI".

Task Standard:

Correctly aligns makeup to the Service Water and Component Cooling Head Tanks.

Rev.2 Page 3of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Evaluation Criteria:

1. All critical steps completed (denoted by shading).
2. All sequential steps completed in order.
3. All time-critical steps completed within allotted time.
4. JPM completed within validated time. Completion time may exceed the validated time if satisfactory progress is being made.

Critical Step Basis:

Critical steps are those that when not performed correctly, in the proper sequence, and/or at the proper time, will prevent the system from functioning properly or preclude successful completion of the task.

General

References:

1. Procedures and manuals normally available in Plant
2. AOP-9A, CONTROL ROOM EVACUATION AND SAFE SHUTDOWN DUE TO A SEVERE CONTROL ROOM FIRE Time critical task:

No Validation Time:

20 minutes Setup:

1. None Rev. 2 Page 4of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 CUE D

D CUE D

CUE:

ELEMENT STANDARD (shaded= CRITICAL STEP)

You have just completed Step CH, ESTABLISH SALTWATER FLOW THROUGH THE COMPONENT COOLING HEAT EXCHANGERS which directs you to "Go to the 69' Aux Building to perform Step CI".

Locate AOP-9A, Step CI Same as element Candidate proceeds to the Unit 2 69' Same as element 2C43 notifies you that makeup has been restored to fill the Service Water and Component Cooling Head Tanks.

When candidate simulates opening 2-CD-145, give feedback that handwheel rotates counter-clockwise until it stops.

CH.1 - WHEN notified that makeup has been restored to fill the Service Water and Component Cooling Head Tanks, Simulates opening 2-CD-145.

THEN:

Open Component Cooling Head Tank Condensate Supply, 2-CD-145.

When candidate simulates opening 2-CD-144, give feedback that handwheel rotates counter-clockwise until it stops.

Open SRW Head Tank Condensate Supply, 2-CD-144.

Simulates opening 2-CD-144.

Rev. 2 Page 5of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT ST AND ARD (shaded= CRITICAL STEP)

CUE:

The component cooling head tank level is below the sight glass.

When candidate simulates opening 2-CC-108, give feedback that handwheel rotates counter-clockwise until it stops.

When candidate simulates shutting 2-CC-107, give feedback that handwheel rotates clockwise until it stops.

D CH.2 - Operate, as necessary, to maintain level indication for the CUE:

D Component Cooling and Service Water Head Tanks:

a. - Component Cooling Head Tank
  • (1) - Open Component Cooling Head Tank Makeup Bypass, 2-CC-Simulates shutting 2-CC-107.

108.

  • (2) - Shut 2-CC-3820-CV Inlet Isol, 2-CC-107.

CC Head tank level is rising and after ~2 minutes simulate that the level is midway in sightglass.

When candidate simulates shutting 2-CC-108, give feedback that handwheel rotates -

clockwise until it stops.

When candidate simulates opening 2-CC-107, give feedback that handwheel rotates counter-clockwise until it stops.

CH.2 - Operate, as necessary, to maintain level indication for the Component Cooling and Service Water Head Tanks:

a. - Component Cooling Head Tank
  • (1) - Open Component Cooling Head Tank Makeup Bypass, 2-CC-Simulates opening 2-CC-107.

108.

  • (2) - Shut 2-CC-3820-CV Inlet Isol, 2-CC-107.

Rev. 2 Page 6of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 ELEMENT STANDARD (shaded= CRITICAL STEP)

CUE:

21 SRW head tank level is normal, 22 SRW head tank level is below the sight glass.

0 CH.2 - Operate, as necessary, to maintain level indication for the Component Cooling and Service Water Head Tanks:

b. - 21 Service Water Heat Tank Determines this step is NOT applicable

CUE:

When candidate simulates opening 2-SR W-114, give feedback that handwheel rotates counter-clockwise until it stops.

When candidate simulates shutting 2-SRW-112, give feedback that handwheel rotates clockwise until it stops.

0 CH.2 - Operate, as necessary, to maintain level indication for the Component Cooling and Service Water Head Tanks:

b. - 22 Service Water Heat Tank

(2) - Shut 22 Service Water Head Tank LCV Inlet Isol, 2-SRW-112.

Simulates shutting 2-SRW-112.

Rev.2 Page 7of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 CUE:

0 0

ELEMENT STANDARD (shaded= CRITICAL STEP) 22 SR W Head tank level is rising and after ::::::2 minutes simulate that the level is midway in sightglass.

When candidate simulates shutting 2-SR W-114, give feedback that handwheel rotates -

clockwise until it stops.

When candidate simulates opening 2-SRW-112, give feedback that handwheel rotates counter-clockwise until it stops.

CH.2 - Operate, as necessary, to maintain level indication for the Component Cooling and Service Water Head Tanks:

b. - 22 Service Water Heat Tank

(2) - Shut 22 Service Water Head Tank LCV Inlet Isol, 2-SRW-112.

CH.3 - Periodically monitor Component Cooling and Service Water Head Tanks levels and fill as necessary.

Simulates opening 2-SR W-112.

Student should voice that this step is continuously applicable.

TERMINATING CUE: This JPM is complete when the Component Cooling and 22 Service Water Head Tanks are in the normal band. No further actions are required. The evaluator is expected to end the JPM TIME STOP: ---

Rev. 2 Page 8of10

Appendix C Job Performance Measure Worksheet Form ES-C-1 Verification of Completion Job Performance Measure IN-PLANT-3 Examinee:

NRC Examiner:

Date Performed:

Facility Evaluator:

Number of Attempts: ________________ _

Time to Complete:

Follow up Question(s): ______________________ _

Applicant Response: ________________________ _

Result:

SAT UNSAT Examiner's Signature and Date: ---------------------

Rev.2 Page 9of10

Appendix C Initial Conditions:

Job Performance Measure Worksheet EXAMINEE'S CUE SHEET Form ES-C-1

1. A severe fire has resulted in Control Room evacuation. AOP-9A has been implemented.
2. You are performing the duties of the Unit-2 ABO.

Initiating Cue:

You have just completed Step CH, ESTABLISH SALTWATER FLOW THROUGH THE COMPONENT COOLING HEAT EXCHANGERS which directs you to "Go to the 69' Aux Building to perform Step CI".

Rev. 2 Page 10of10