Subject:

ORIGEN, COMPLY and MicroShield results used for MHA and FHA calcula@ons in UFTR FSAR Chapter 13 dated March 6, 2017 Date:

Monday, March 6, 2017 at 1:42:29 PM Eastern Standard Time From:

Cronin,Dan To:

Duane Hardesty, Helvenston, Edward CC:

Shea,Brian C, Baciak,James Edward AUached are the ORIGEN, COMPLY and MicroShield results used for the MHA and FHA calcula@ons in the FSAR Chapter 13 dated March 6, 2017.

Daniel J. Cronin Licensing Engineer l University of Florida Training Reactor dcronin@u".edu l 352-294-2103 l 352-454-0424 Cell

time ag109 am241 am242m am243 cm242 cm243 cm244 cm245 cs133 eu153 gd155 i129 (days)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci) 0.00E+00 0.00E+00 3.93E-12 0.00E+00 2.31E-13 3.82E-09 5.85E-11 9.40E-11 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.08E-16 5.00E+00 0.00E+00 3.94E-12 2.72E-19 2.31E-13 6.82E-09 5.85E-11 9.40E-11 4.09E-21 0.00E+00 0.00E+00 0.00E+00 1.54E-08 1.00E+01 0.00E+00 3.94E-12 5.43E-19 2.31E-13 6.70E-09 5.85E-11 9.39E-11 8.13E-21 0.00E+00 0.00E+00 0.00E+00 3.19E-08 1.50E+01 0.00E+00 3.94E-12 8.15E-19 2.31E-13 6.56E-09 5.84E-11 9.39E-11 1.22E-20 0.00E+00 0.00E+00 0.00E+00 4.84E-08 2.00E+01 0.00E+00 3.94E-12 1.09E-18 2.31E-13 6.42E-09 5.84E-11 9.38E-11 1.62E-20 0.00E+00 0.00E+00 0.00E+00 6.49E-08 2.50E+01 0.00E+00 3.95E-12 1.36E-18 2.31E-13 6.28E-09 5.84E-11 9.38E-11 2.03E-20 0.00E+00 0.00E+00 0.00E+00 8.14E-08 3.00E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.15E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.79E-08 3.09E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.13E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.89E-08 3.18E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.10E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.27E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.08E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.36E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.06E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.46E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.03E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.55E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 6.01E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.64E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 5.99E-09 5.84E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.73E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 5.96E-09 5.83E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.82E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 5.94E-09 5.83E-11 9.37E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 3.91E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 5.92E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.00E+01 0.00E+00 3.95E-12 1.63E-18 2.31E-13 5.89E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.09E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.87E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.18E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.85E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.27E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.83E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.36E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.80E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.46E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.78E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.55E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.76E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.64E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.74E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.73E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.72E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.82E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.69E-09 5.83E-11 9.36E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 4.91E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.67E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.00E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.65E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.09E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.63E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.18E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.61E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.27E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.58E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.36E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.56E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.46E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.54E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08

5.55E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.52E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.64E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.50E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.73E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.48E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.82E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.46E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 5.91E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.43E-09 5.83E-11 9.35E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.00E+01 0.00E+00 3.96E-12 1.63E-18 2.31E-13 5.41E-09 5.83E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.897E-08 6.09E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.39E-09 5.83E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.18E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.37E-09 5.83E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.27E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.35E-09 5.83E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.36E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.33E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.46E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.31E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.55E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.29E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.64E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.27E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.73E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.25E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.82E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.23E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 6.91E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.21E-09 5.82E-11 9.34E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.00E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.19E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.09E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.17E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.18E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.15E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.27E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.13E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.36E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.11E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.46E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.09E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.55E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.07E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.64E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.05E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.73E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.03E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.82E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 5.01E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 7.91E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 4.99E-09 5.82E-11 9.33E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.00E+01 0.00E+00 3.97E-12 1.63E-18 2.31E-13 4.97E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.09E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.95E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.18E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.93E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.27E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.91E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.36E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.90E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.46E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.88E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.55E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.86E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.64E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.84E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.73E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.82E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08

8.82E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.80E-09 5.82E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 8.91E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.78E-09 5.81E-11 9.32E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.00E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.76E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.09E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.75E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.18E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.73E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.27E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.71E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.36E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.69E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.46E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.67E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.55E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.66E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.64E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.64E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.73E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.62E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.82E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.60E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 9.91E+01 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.58E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.00E+02 0.00E+00 3.98E-12 1.63E-18 2.31E-13 4.57E-09 5.81E-11 9.31E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.01E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.55E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.02E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.53E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.03E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.51E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.04E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.50E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.05E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.48E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.06E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.46E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.06E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.44E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.07E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.43E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.08E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.41E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.09E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.39E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.10E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.38E-09 5.81E-11 9.30E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.11E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.36E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.12E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.34E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.13E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.33E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.14E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.31E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.15E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.29E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.16E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.28E-09 5.81E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.16E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.26E-09 5.80E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.17E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.24E-09 5.80E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.18E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.23E-09 5.80E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.19E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.21E-09 5.80E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08 1.20E+02 0.00E+00 3.99E-12 1.63E-18 2.31E-13 4.19E-09 5.80E-11 9.29E-11 2.43E-20 0.00E+00 0.00E+00 0.00E+00 9.90E-08

time i130 i131 i132 i133 i135 kr85 kr85m kr88 mo95 nd143 nd145 o16 (days)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci) 0.00E+00 9.76E-23 1.58E-22 3.12E-20 3.13E-20 2.27E-06 2.10E-24 1.02E-20 4.75E-18 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.00E+00 9.86E-03 4.70E+01 1.37E+02 3.13E+02 2.96E+02 1.47E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.00E+01 9.88E-03 7.90E+01 1.84E+02 3.19E+02 2.96E+02 3.00E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.50E+01 9.88E-03 9.98E+01 2.00E+02 3.19E+02 2.96E+02 4.53E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.00E+01 9.88E-03 1.13E+02 2.05E+02 3.19E+02 2.96E+02 6.06E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 2.50E+01 9.88E-03 1.22E+02 2.07E+02 3.19E+02 2.96E+02 7.58E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.00E+01 9.88E-03 1.28E+02 2.08E+02 3.19E+02 2.96E+02 9.11E-02 6.32E+01 1.66E+02 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.09E+01 2.92E-03 1.19E+02 1.71E+02 1.58E+02 2.96E+01 9.17E-02 2.19E+00 8.06E-01 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.18E+01 8.58E-04 1.11E+02 1.41E+02 7.65E+01 2.96E+00 9.17E-02 7.48E-02 3.93E-03 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.27E+01 2.52E-04 1.03E+02 1.16E+02 3.70E+01 2.96E-01 9.17E-02 2.56E-03 2.22E-05 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.36E+01 7.42E-05 9.50E+01 9.50E+01 1.79E+01 2.97E-02 9.17E-02 8.86E-05 3.13E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.46E+01 2.18E-05 8.79E+01 7.80E+01 8.64E+00 2.97E-03 9.16E-02 4.16E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.55E+01 6.42E-06 8.13E+01 6.41E+01 4.17E+00 3.03E-04 9.16E-02 1.27E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.64E+01 1.89E-06 7.52E+01 5.26E+01 2.02E+00 3.52E-05 9.16E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.73E+01 5.56E-07 6.95E+01 4.32E+01 9.75E-01 8.40E-06 9.16E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.82E+01 1.64E-07 6.43E+01 3.55E+01 4.71E-01 5.73E-06 9.16E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 3.91E+01 4.83E-08 5.94E+01 2.92E+01 2.28E-01 5.46E-06 9.16E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.00E+01 1.43E-08 5.49E+01 2.40E+01 1.10E-01 5.43E-06 9.16E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.09E+01 4.35E-09 5.08E+01 1.97E+01 5.32E-02 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.18E+01 1.41E-09 4.70E+01 1.62E+01 2.57E-02 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.27E+01 5.43E-10 4.34E+01 1.33E+01 1.24E-02 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.36E+01 2.89E-10 4.01E+01 1.09E+01 6.01E-03 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.46E+01 2.14E-10 3.71E+01 8.97E+00 2.91E-03 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.55E+01 1.92E-10 3.43E+01 7.37E+00 1.41E-03 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.64E+01 1.85E-10 3.17E+01 6.05E+00 6.84E-04 5.43E-06 9.15E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.73E+01 1.84E-10 2.93E+01 4.97E+00 3.34E-04 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.82E+01 1.83E-10 2.71E+01 4.08E+00 1.64E-04 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.91E+01 1.83E-10 2.50E+01 3.35E+00 8.25E-05 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.00E+01 1.83E-10 2.32E+01 2.76E+00 4.30E-05 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.09E+01 1.83E-10 2.14E+01 2.26E+00 2.38E-05 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00

5.18E+01 1.83E-10 1.98E+01 1.86E+00 1.46E-05 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.27E+01 1.83E-10 1.83E+01 1.53E+00 1.01E-05 5.43E-06 9.14E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.36E+01 1.83E-10 1.69E+01 1.25E+00 7.97E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.46E+01 1.83E-10 1.56E+01 1.03E+00 6.93E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.55E+01 1.83E-10 1.45E+01 8.47E-01 6.43E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.64E+01 1.83E-10 1.34E+01 6.95E-01 6.18E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.73E+01 1.83E-10 1.24E+01 5.71E-01 6.07E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.82E+01 1.83E-10 1.14E+01 4.69E-01 6.01E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 5.91E+01 1.83E-10 1.06E+01 3.85E-01 5.98E-06 5.43E-06 9.13E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.00E+01 1.827E-10 9.755E+00 3.166E-01 5.967E-06 5.427E-06 9.123E-02 1.168E-06 3.036E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.09E+01 1.83E-10 9.02E+00 2.60E-01 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.18E+01 1.83E-10 8.34E+00 2.14E-01 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.27E+01 1.83E-10 7.71E+00 1.76E-01 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.36E+01 1.83E-10 7.13E+00 1.44E-01 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.46E+01 1.83E-10 6.59E+00 1.18E-01 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.55E+01 1.83E-10 6.09E+00 9.73E-02 5.96E-06 5.43E-06 9.12E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.64E+01 1.83E-10 5.63E+00 7.99E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.73E+01 1.83E-10 5.20E+00 6.57E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.82E+01 1.83E-10 4.81E+00 5.39E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 6.91E+01 1.83E-10 4.45E+00 4.43E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.00E+01 1.83E-10 4.11E+00 3.64E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.09E+01 1.83E-10 3.80E+00 2.99E-02 5.96E-06 5.43E-06 9.11E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.18E+01 1.83E-10 3.51E+00 2.46E-02 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.27E+01 1.83E-10 3.25E+00 2.02E-02 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.36E+01 1.83E-10 3.00E+00 1.66E-02 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.46E+01 1.83E-10 2.78E+00 1.36E-02 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.55E+01 1.83E-10 2.57E+00 1.12E-02 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.64E+01 1.83E-10 2.37E+00 9.19E-03 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.73E+01 1.83E-10 2.19E+00 7.55E-03 5.96E-06 5.43E-06 9.10E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.82E+01 1.83E-10 2.03E+00 6.20E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 7.91E+01 1.83E-10 1.87E+00 5.10E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.00E+01 1.83E-10 1.73E+00 4.19E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.09E+01 1.83E-10 1.60E+00 3.44E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.18E+01 1.83E-10 1.48E+00 2.83E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.27E+01 1.83E-10 1.37E+00 2.32E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.36E+01 1.83E-10 1.27E+00 1.91E-03 5.96E-06 5.43E-06 9.09E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00

8.46E+01 1.83E-10 1.17E+00 1.57E-03 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.55E+01 1.83E-10 1.08E+00 1.29E-03 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.64E+01 1.83E-10 1.00E+00 1.06E-03 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.73E+01 1.83E-10 9.24E-01 8.71E-04 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.82E+01 1.83E-10 8.54E-01 7.16E-04 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 8.91E+01 1.83E-10 7.90E-01 5.89E-04 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.00E+01 1.83E-10 7.30E-01 4.85E-04 5.96E-06 5.43E-06 9.08E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.09E+01 1.83E-10 6.75E-01 3.99E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.18E+01 1.83E-10 6.24E-01 3.28E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.27E+01 1.83E-10 5.77E-01 2.70E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.36E+01 1.83E-10 5.33E-01 2.23E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.46E+01 1.83E-10 4.93E-01 1.84E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.55E+01 1.83E-10 4.56E-01 1.52E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.64E+01 1.83E-10 4.21E-01 1.25E-04 5.96E-06 5.43E-06 9.07E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.73E+01 1.83E-10 3.89E-01 1.03E-04 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.82E+01 1.83E-10 3.60E-01 8.56E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 9.91E+01 1.83E-10 3.33E-01 7.10E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.00E+02 1.83E-10 3.08E-01 5.90E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.01E+02 1.83E-10 2.84E-01 4.92E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.02E+02 1.83E-10 2.63E-01 4.10E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.03E+02 1.83E-10 2.43E-01 3.44E-05 5.96E-06 5.43E-06 9.06E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.04E+02 1.83E-10 2.25E-01 2.89E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.05E+02 1.83E-10 2.08E-01 2.44E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.06E+02 1.83E-10 1.92E-01 2.07E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.06E+02 1.83E-10 1.78E-01 1.77E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.07E+02 1.83E-10 1.64E-01 1.52E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.08E+02 1.83E-10 1.52E-01 1.32E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.09E+02 1.83E-10 1.40E-01 1.15E-05 5.96E-06 5.43E-06 9.05E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.10E+02 1.83E-10 1.30E-01 1.01E-05 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.11E+02 1.83E-10 1.20E-01 8.98E-06 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.12E+02 1.83E-10 1.11E-01 8.04E-06 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.13E+02 1.83E-10 1.02E-01 7.28E-06 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.14E+02 1.83E-10 9.47E-02 6.65E-06 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.15E+02 1.83E-10 8.75E-02 6.13E-06 5.96E-06 5.43E-06 9.04E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.16E+02 1.83E-10 8.09E-02 5.71E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.16E+02 1.83E-10 7.48E-02 5.36E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00

1.17E+02 1.83E-10 6.91E-02 5.08E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.18E+02 1.83E-10 6.39E-02 4.84E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.19E+02 1.83E-10 5.91E-02 4.65E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.20E+02 1.83E-10 5.46E-02 4.49E-06 5.96E-06 5.43E-06 9.03E-02 1.17E-06 3.04E-06 0.00E+00 0.00E+00 0.00E+00 0.00E+00 time pm147 pu238 pu239 pu240 pu241 pu242 pu243 rh103 ru101 sm147 sm149 sm150 (days)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci) 0.00E+00 6.49E-10 1.94E-11 7.06E-14 2.59E-13 1.19E-10 4.54E-15 0.00E+00 0.00E+00 0.00E+00 1.61E-20 0.00E+00 0.00E+00 5.00E+00 5.48E-02 2.05E-11 4.09E-05 9.49E-12 1.19E-10 5.32E-15 7.57E-15 0.00E+00 0.00E+00 1.68E-15 0.00E+00 0.00E+00 1.00E+01 1.99E-01 2.57E-11 1.17E-04 4.66E-11 1.19E-10 5.32E-15 7.59E-15 0.00E+00 0.00E+00 1.25E-14 0.00E+00 0.00E+00 1.50E+01 4.08E-01 3.97E-11 2.01E-04 1.17E-10 1.19E-10 5.32E-15 7.64E-15 0.00E+00 0.00E+00 3.92E-14 0.00E+00 0.00E+00 2.00E+01 6.64E-01 6.62E-11 2.87E-04 2.22E-10 1.19E-10 5.32E-15 7.64E-15 0.00E+00 0.00E+00 8.69E-14 0.00E+00 0.00E+00 2.50E+01 9.54E-01 1.07E-10 3.73E-04 3.61E-10 1.19E-10 5.32E-15 7.67E-15 0.00E+00 0.00E+00 1.59E-13 0.00E+00 0.00E+00 3.00E+01 1.27E+00 1.64E-10 4.59E-04 5.35E-10 1.19E-10 5.32E-15 7.66E-15 0.00E+00 0.00E+00 2.58E-13 0.00E+00 0.00E+00 3.09E+01 1.33E+00 1.75E-10 4.73E-04 5.35E-10 1.19E-10 5.32E-15 3.62E-16 0.00E+00 0.00E+00 2.79E-13 0.00E+00 0.00E+00 3.18E+01 1.38E+00 1.82E-10 4.83E-04 5.35E-10 1.19E-10 5.32E-15 1.71E-17 0.00E+00 0.00E+00 3.01E-13 0.00E+00 0.00E+00 3.27E+01 1.43E+00 1.88E-10 4.91E-04 5.35E-10 1.19E-10 5.32E-15 8.10E-19 0.00E+00 0.00E+00 3.24E-13 0.00E+00 0.00E+00 3.36E+01 1.48E+00 1.92E-10 4.98E-04 5.35E-10 1.19E-10 5.32E-15 3.84E-20 0.00E+00 0.00E+00 3.48E-13 0.00E+00 0.00E+00 3.46E+01 1.52E+00 1.95E-10 5.02E-04 5.35E-10 1.19E-10 5.32E-15 1.95E-21 0.00E+00 0.00E+00 3.72E-13 0.00E+00 0.00E+00 3.55E+01 1.57E+00 1.98E-10 5.06E-04 5.35E-10 1.19E-10 5.32E-15 2.24E-22 0.00E+00 0.00E+00 3.98E-13 0.00E+00 0.00E+00 3.64E+01 1.61E+00 2.00E-10 5.09E-04 5.35E-10 1.19E-10 5.32E-15 1.44E-22 0.00E+00 0.00E+00 4.23E-13 0.00E+00 0.00E+00 3.73E+01 1.64E+00 2.01E-10 5.11E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 4.50E-13 0.00E+00 0.00E+00 3.82E+01 1.68E+00 2.02E-10 5.13E-04 5.35E-10 1.19E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 4.77E-13 0.00E+00 0.00E+00 3.91E+01 1.71E+00 2.03E-10 5.14E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 5.04E-13 0.00E+00 0.00E+00 4.00E+01 1.74E+00 2.04E-10 5.15E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 5.33E-13 0.00E+00 0.00E+00 4.09E+01 1.77E+00 2.04E-10 5.16E-04 5.35E-10 1.19E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 5.61E-13 0.00E+00 0.00E+00 4.18E+01 1.80E+00 2.04E-10 5.16E-04 5.35E-10 1.19E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 5.90E-13 0.00E+00 0.00E+00 4.27E+01 1.83E+00 2.05E-10 5.17E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 6.20E-13 0.00E+00 0.00E+00 4.36E+01 1.85E+00 2.05E-10 5.17E-04 5.35E-10 1.19E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 6.50E-13 0.00E+00 0.00E+00 4.46E+01 1.88E+00 2.05E-10 5.17E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 6.80E-13 0.00E+00 0.00E+00 4.55E+01 1.90E+00 2.05E-10 5.17E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 7.11E-13 0.00E+00 0.00E+00 4.64E+01 1.92E+00 2.06E-10 5.17E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 7.42E-13 0.00E+00 0.00E+00 4.73E+01 1.94E+00 2.06E-10 5.18E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 7.73E-13 0.00E+00 0.00E+00

4.82E+01 1.96E+00 2.06E-10 5.18E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 8.05E-13 0.00E+00 0.00E+00 4.91E+01 1.97E+00 2.06E-10 5.18E-04 5.35E-10 1.19E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 8.37E-13 0.00E+00 0.00E+00 5.00E+01 1.99E+00 2.06E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 8.69E-13 0.00E+00 0.00E+00 5.09E+01 2.00E+00 2.06E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 9.02E-13 0.00E+00 0.00E+00 5.18E+01 2.02E+00 2.06E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 9.34E-13 0.00E+00 0.00E+00 5.27E+01 2.03E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 9.67E-13 0.00E+00 0.00E+00 5.36E+01 2.04E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.00E-12 0.00E+00 0.00E+00 5.46E+01 2.06E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.03E-12 0.00E+00 0.00E+00 5.55E+01 2.07E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.07E-12 0.00E+00 0.00E+00 5.64E+01 2.08E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.10E-12 0.00E+00 0.00E+00 5.73E+01 2.09E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 1.14E-12 0.00E+00 0.00E+00 5.82E+01 2.10E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.17E-12 0.00E+00 0.00E+00 5.91E+01 2.10E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.20E-12 0.00E+00 0.00E+00 6.00E+01 2.11E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.24E-12 0.00E+00 0.00E+00 6.09E+01 2.12E+00 2.07E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.27E-12 0.00E+00 0.00E+00 6.18E+01 2.13E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.31E-12 0.00E+00 0.00E+00 6.27E+01 2.13E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 1.34E-12 0.00E+00 0.00E+00 6.36E+01 2.14E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.38E-12 0.00E+00 0.00E+00 6.46E+01 2.14E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.41E-12 0.00E+00 0.00E+00 6.55E+01 2.15E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.45E-12 0.00E+00 0.00E+00 6.64E+01 2.15E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.48E-12 0.00E+00 0.00E+00 6.73E+01 2.16E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 1.52E-12 0.00E+00 0.00E+00 6.82E+01 2.16E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.55E-12 0.00E+00 0.00E+00 6.91E+01 2.17E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.41E-22 0.00E+00 0.00E+00 1.59E-12 0.00E+00 0.00E+00 7.00E+01 2.17E+00 2.08E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.37E-22 0.00E+00 0.00E+00 1.62E-12 0.00E+00 0.00E+00 7.09E+01 2.17E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.66E-12 0.00E+00 0.00E+00 7.18E+01 2.18E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.69E-12 0.00E+00 0.00E+00 7.27E+01 2.18E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.73E-12 0.00E+00 0.00E+00 7.36E+01 2.18E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.76E-12 0.00E+00 0.00E+00 7.46E+01 2.18E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.80E-12 0.00E+00 0.00E+00 7.55E+01 2.19E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 1.83E-12 0.00E+00 0.00E+00 7.64E+01 2.19E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.87E-12 0.00E+00 0.00E+00 7.73E+01 2.19E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.91E-12 0.00E+00 0.00E+00 7.82E+01 2.19E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.94E-12 0.00E+00 0.00E+00 7.91E+01 2.19E+00 2.09E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 1.98E-12 0.00E+00 0.00E+00 8.00E+01 2.19E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.01E-12 0.00E+00 0.00E+00

8.09E+01 2.19E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.05E-12 0.00E+00 0.00E+00 8.18E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.08E-12 0.00E+00 0.00E+00 8.27E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.12E-12 0.00E+00 0.00E+00 8.36E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.16E-12 0.00E+00 0.00E+00 8.46E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.19E-12 0.00E+00 0.00E+00 8.55E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.23E-12 0.00E+00 0.00E+00 8.64E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.26E-12 0.00E+00 0.00E+00 8.73E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.41E-22 0.00E+00 0.00E+00 2.30E-12 0.00E+00 0.00E+00 8.82E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.33E-12 0.00E+00 0.00E+00 8.91E+01 2.20E+00 2.10E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 2.37E-12 0.00E+00 0.00E+00 9.00E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.41E-12 0.00E+00 0.00E+00 9.09E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.44E-12 0.00E+00 0.00E+00 9.18E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.48E-12 0.00E+00 0.00E+00 9.27E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.51E-12 0.00E+00 0.00E+00 9.36E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 2.55E-12 0.00E+00 0.00E+00 9.46E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 2.58E-12 0.00E+00 0.00E+00 9.55E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.62E-12 0.00E+00 0.00E+00 9.64E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.66E-12 0.00E+00 0.00E+00 9.73E+01 2.20E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.69E-12 0.00E+00 0.00E+00 9.82E+01 2.19E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 2.73E-12 0.00E+00 0.00E+00 9.91E+01 2.19E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.76E-12 0.00E+00 0.00E+00 1.00E+02 2.19E+00 2.11E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.80E-12 0.00E+00 0.00E+00 1.01E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.83E-12 0.00E+00 0.00E+00 1.02E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.87E-12 0.00E+00 0.00E+00 1.03E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.91E-12 0.00E+00 0.00E+00 1.04E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 2.94E-12 0.00E+00 0.00E+00 1.05E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 2.98E-12 0.00E+00 0.00E+00 1.06E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 3.01E-12 0.00E+00 0.00E+00 1.06E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 3.05E-12 0.00E+00 0.00E+00 1.07E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.37E-22 0.00E+00 0.00E+00 3.08E-12 0.00E+00 0.00E+00 1.08E+02 2.19E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.12E-12 0.00E+00 0.00E+00 1.09E+02 2.18E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 3.16E-12 0.00E+00 0.00E+00 1.10E+02 2.18E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 3.19E-12 0.00E+00 0.00E+00 1.11E+02 2.18E+00 2.12E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.23E-12 0.00E+00 0.00E+00 1.12E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.37E-22 0.00E+00 0.00E+00 3.26E-12 0.00E+00 0.00E+00 1.13E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.18E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 3.30E-12 0.00E+00 0.00E+00

1.14E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.40E-22 0.00E+00 0.00E+00 3.33E-12 0.00E+00 0.00E+00 1.15E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.37E-12 0.00E+00 0.00E+00 1.16E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.40E-12 0.00E+00 0.00E+00 1.16E+02 2.18E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 3.44E-12 0.00E+00 0.00E+00 1.17E+02 2.17E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.47E-12 0.00E+00 0.00E+00 1.18E+02 2.17E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 3.51E-12 0.00E+00 0.00E+00 1.19E+02 2.17E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.38E-22 0.00E+00 0.00E+00 3.55E-12 0.00E+00 0.00E+00 1.20E+02 2.17E+00 2.13E-10 5.18E-04 5.35E-10 1.17E-10 5.32E-15 1.39E-22 0.00E+00 0.00E+00 3.58E-12 0.00E+00 0.00E+00 time sm151 sm152 tc99 u234 u235 u236 u238 xe131 xe133 xe133m xe135 xe135m (days)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci)

(Ci) 0.00E+00 5.69E+00 0.00E+00 8.06E-15 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.19E-07 2.83E-22 1.63E-06 5.46E-18 5.00E+00 5.69E+00 0.00E+00 5.01E-06 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.23E+02 2.31E+00 3.08E+02 3.75E+01 1.00E+01 5.69E+00 0.00E+00 1.57E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.18E+02 3.20E+00 3.08E+02 3.75E+01 1.50E+01 5.69E+00 0.00E+00 2.79E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.69E+02 3.39E+00 3.08E+02 3.75E+01 2.00E+01 5.69E+00 0.00E+00 4.06E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.94E+02 3.43E+00 3.08E+02 3.75E+01 2.50E+01 5.70E+00 0.00E+00 5.35E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.08E+02 3.43E+00 3.08E+02 3.75E+01 3.00E+01 5.70E+00 0.00E+00 6.64E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.15E+02 3.44E+00 3.08E+02 3.75E+01 3.09E+01 5.70E+00 0.00E+00 6.86E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.05E+02 3.17E+00 1.28E+02 3.04E+00 3.18E+01 5.70E+00 0.00E+00 7.04E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.84E+02 2.67E+00 3.14E+01 3.04E-01 3.27E+01 5.70E+00 0.00E+00 7.18E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.58E+02 2.14E+00 6.69E+00 3.04E-02 3.36E+01 5.70E+00 0.00E+00 7.30E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.32E+02 1.67E+00 1.35E+00 3.04E-03 3.46E+01 5.70E+00 0.00E+00 7.39E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.07E+02 1.29E+00 2.65E-01 3.05E-04 3.55E+01 5.70E+00 0.00E+00 7.46E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.84E+02 9.79E-01 5.13E-02 3.12E-05 3.64E+01 5.70E+00 0.00E+00 7.52E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.64E+02 7.42E-01 9.88E-03 3.75E-06 3.73E+01 5.70E+00 0.00E+00 7.57E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.46E+02 5.60E-01 1.90E-03 1.01E-06 3.82E+01 5.70E+00 0.00E+00 7.60E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.29E+02 4.22E-01 3.68E-04 7.31E-07 3.91E+01 5.70E+00 0.00E+00 7.63E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.15E+02 3.17E-01 7.51E-05 7.03E-07 4.00E+01 5.70E+00 0.00E+00 7.65E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.02E+02 2.38E-01 1.89E-05 7.01E-07 4.09E+01 5.70E+00 0.00E+00 7.67E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 9.03E+01 1.79E-01 8.20E-06 7.00E-07 4.18E+01 5.70E+00 0.00E+00 7.69E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 8.01E+01 1.34E-01 6.15E-06 7.00E-07 4.27E+01 5.70E+00 0.00E+00 7.70E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 7.10E+01 1.01E-01 5.75E-06 7.00E-07 4.36E+01 5.70E+00 0.00E+00 7.71E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.30E+01 7.56E-02 5.68E-06 7.00E-07

4.46E+01 5.70E+00 0.00E+00 7.71E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.59E+01 5.67E-02 5.66E-06 7.00E-07 4.55E+01 5.70E+00 0.00E+00 7.72E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.95E+01 4.25E-02 5.66E-06 7.00E-07 4.64E+01 5.70E+00 0.00E+00 7.72E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.39E+01 3.19E-02 5.66E-06 7.00E-07 4.73E+01 5.70E+00 0.00E+00 7.73E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.90E+01 2.39E-02 5.66E-06 7.00E-07 4.82E+01 5.70E+00 0.00E+00 7.73E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.46E+01 1.79E-02 5.66E-06 7.00E-07 4.91E+01 5.70E+00 0.00E+00 7.73E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.06E+01 1.35E-02 5.66E-06 7.00E-07 5.00E+01 5.70E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.72E+01 1.01E-02 5.66E-06 7.00E-07 5.09E+01 5.70E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.41E+01 7.57E-03 5.66E-06 7.00E-07 5.18E+01 5.70E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.14E+01 5.68E-03 5.66E-06 7.00E-07 5.27E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.90E+01 4.26E-03 5.66E-06 7.00E-07 5.36E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.68E+01 3.19E-03 5.66E-06 7.00E-07 5.46E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.49E+01 2.39E-03 5.66E-06 7.00E-07 5.55E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.32E+01 1.80E-03 5.66E-06 7.00E-07 5.64E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.17E+01 1.35E-03 5.66E-06 7.00E-07 5.73E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.04E+01 1.01E-03 5.66E-06 7.00E-07 5.82E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 9.21E+00 7.58E-04 5.66E-06 7.00E-07 5.91E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 8.17E+00 5.68E-04 5.66E-06 7.00E-07 6.00E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 7.245E+00 4.261E-04 5.661E-06 7.003E-07 6.09E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.43E+00 3.20E-04 5.66E-06 7.00E-07 6.18E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.70E+00 2.40E-04 5.66E-06 7.00E-07 6.27E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.05E+00 1.80E-04 5.66E-06 7.00E-07 6.36E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.48E+00 1.35E-04 5.66E-06 7.00E-07 6.46E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.97E+00 1.01E-04 5.66E-06 7.00E-07 6.55E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.52E+00 7.59E-05 5.66E-06 7.00E-07 6.64E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.12E+00 5.69E-05 5.66E-06 7.00E-07 6.73E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.77E+00 4.27E-05 5.66E-06 7.00E-07 6.82E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.46E+00 3.20E-05 5.66E-06 7.00E-07 6.91E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.18E+00 2.40E-05 5.66E-06 7.00E-07 7.00E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.93E+00 1.81E-05 5.66E-06 7.00E-07 7.09E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.71E+00 1.36E-05 5.66E-06 7.00E-07 7.18E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.52E+00 1.02E-05 5.66E-06 7.00E-07 7.27E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.35E+00 7.65E-06 5.66E-06 7.00E-07 7.36E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.19E+00 5.75E-06 5.66E-06 7.00E-07 7.46E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.06E+00 4.33E-06 5.66E-06 7.00E-07 7.55E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 9.39E-01 3.26E-06 5.66E-06 7.00E-07 7.64E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 8.33E-01 2.46E-06 5.66E-06 7.00E-07

7.73E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 7.39E-01 1.86E-06 5.66E-06 7.00E-07 7.82E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.55E-01 1.41E-06 5.66E-06 7.00E-07 7.91E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.81E-01 1.08E-06 5.66E-06 7.00E-07 8.00E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.15E-01 8.23E-07 5.66E-06 7.00E-07 8.09E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.57E-01 6.33E-07 5.66E-06 7.00E-07 8.18E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.05E-01 4.91E-07 5.66E-06 7.00E-07 8.27E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.59E-01 3.84E-07 5.66E-06 7.00E-07 8.36E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.18E-01 3.04E-07 5.66E-06 7.00E-07 8.46E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.82E-01 2.44E-07 5.66E-06 7.00E-07 8.55E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.50E-01 1.99E-07 5.66E-06 7.00E-07 8.64E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.22E-01 1.65E-07 5.66E-06 7.00E-07 8.73E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.97E-01 1.40E-07 5.66E-06 7.00E-07 8.82E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.75E-01 1.21E-07 5.66E-06 7.00E-07 8.91E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.55E-01 1.07E-07 5.66E-06 7.00E-07 9.00E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.37E-01 9.58E-08 5.66E-06 7.00E-07 9.09E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.22E-01 8.78E-08 5.66E-06 7.00E-07 9.18E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.08E-01 8.18E-08 5.66E-06 7.00E-07 9.27E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 9.57E-02 7.73E-08 5.66E-06 7.00E-07 9.36E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 8.49E-02 7.39E-08 5.66E-06 7.00E-07 9.46E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 7.53E-02 7.13E-08 5.66E-06 7.00E-07 9.55E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.68E-02 6.94E-08 5.66E-06 7.00E-07 9.64E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.92E-02 6.80E-08 5.66E-06 7.00E-07 9.73E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.25E-02 6.70E-08 5.66E-06 7.00E-07 9.82E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.66E-02 6.62E-08 5.66E-06 7.00E-07 9.91E+01 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.13E-02 6.56E-08 5.66E-06 7.00E-07 1.00E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.66E-02 6.51E-08 5.66E-06 7.00E-07 1.01E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.25E-02 6.48E-08 5.66E-06 7.00E-07 1.02E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.88E-02 6.45E-08 5.66E-06 7.00E-07 1.03E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.55E-02 6.43E-08 5.66E-06 7.00E-07 1.04E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.26E-02 6.42E-08 5.66E-06 7.00E-07 1.05E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.01E-02 6.41E-08 5.66E-06 7.00E-07 1.06E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.78E-02 6.40E-08 5.66E-06 7.00E-07 1.06E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.58E-02 6.39E-08 5.66E-06 7.00E-07 1.07E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.40E-02 6.39E-08 5.66E-06 7.00E-07 1.08E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.24E-02 6.38E-08 5.66E-06 7.00E-07 1.09E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 1.10E-02 6.38E-08 5.66E-06 7.00E-07

1.10E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 9.76E-03 6.38E-08 5.66E-06 7.00E-07 1.11E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 8.66E-03 6.38E-08 5.66E-06 7.00E-07 1.12E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 7.68E-03 6.38E-08 5.66E-06 7.00E-07 1.13E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.81E-03 6.38E-08 5.66E-06 7.00E-07 1.14E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 6.04E-03 6.38E-08 5.66E-06 7.00E-07 1.15E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 5.36E-03 6.38E-08 5.66E-06 7.00E-07 1.16E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.75E-03 6.38E-08 5.66E-06 7.00E-07 1.16E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 4.21E-03 6.38E-08 5.66E-06 7.00E-07 1.17E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.74E-03 6.38E-08 5.66E-06 7.00E-07 1.18E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 3.31E-03 6.38E-08 5.66E-06 7.00E-07 1.19E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.94E-03 6.38E-08 5.66E-06 7.00E-07 1.20E+02 5.69E+00 0.00E+00 7.74E-05 1.01E+01 4.26E-01 6.70E-02 2.69E-01 0.00E+00 2.61E-03 6.38E-08 5.66E-06 7.00E-07 1

COMPLY: V1.6. 2/23/2017 12:14 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE - V1.6.

Prepared by:

UFTR UFTR Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

COMPLY: V1.6. 2/23/2017 12:14 FHA Feb 2017 SCREENING LEVEL 3 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

KR-85 1.750E-04 KR-85M 2.241E-09 KR-88 5.825E-09 I-129 D 4.748E-11 I-130 D 8.764E-14 I-131 D 4.679E-03 I-132 D 1.519E-04 I-133 D 2.862E-09 I-135 D 2.603E-09 XE-133 1.390E-02 XE-133M 8.176E-07 XE-135 1.086E-08 XE-135M 1.344E-09 Release height 9 meters.

Building height 8 meters.

The source and receptor are not on the same building.

Distance from the source to the receptor is 10 meters.

Building width 19 meters.

Default mean wind speed used (2.0 m/sec).

Distance from the SOURCE to the FARM producing VEGETABLES is 1350 meters.

Distance from the SOURCE to the FARM producing MILK and MEAT is 2700 meters.

NOTES:

Input parameters outside the "normal" range:

None.

COMPLY: V1.6. 2/23/2017 12:14 RESULTS:

Effective dose equivalent: 0.5 mrem/yr.

Effective dose equivalent: 0.5 mrem/yr due to Iodine.

      • Comply at level 3.

This facility is in COMPLIANCE.

It may or may not be EXEMPT from reporting to the EPA.

You may contact your regional EPA office for more information.

                    • END OF COMPLIANCE REPORT **********

COMPLY: V1.6. 2/23/2017 2:48 40 CFR Part 61 National Emission Standards for Hazardous Air Pollutants REPORT ON COMPLIANCE WITH THE CLEAN AIR ACT LIMITS FOR RADIONUCLIDE EMISSIONS FROM THE COMPLY CODE - V1.6.

Prepared by:

UFTR Prepared for:

U.S. Environmental Protection Agency Office of Radiation and Indoor Air Washington, DC 20460

COMPLY: V1.6. 2/23/2017 2:48 MHA Feb 2017 SCREENING LEVEL 3 DATA ENTERED:

Release Rate Nuclide (curies/YEAR)

KR-85 2.451E-03 KR-85M 3.138E-08 KR-88 8.156E-08 I-129 D 6.647E-10 I-130 D 1.227E-12 I-131 D 6.551E-02 I-132 D 2.126E-03 I-133 D 4.007E-08 I-135 D 3.645E-08 XE-133 1.946E-01 XE-133M 1.145E-05 XE-135 1.521E-07 XE-135M 1.881E-08 Release height 9 meters.

Building height 8 meters.

The source and receptor are not on the same building.

Distance from the source to the receptor is 10 meters.

Building width 19 meters.

Default mean wind speed used (2.0 m/sec).

Distance from the SOURCE to the FARM producing VEGETABLES is 1350 meters.

Distance from the SOURCE to the FARM producing MILK and MEAT is 2700 meters.

NOTES:

Input parameters outside the "normal" range:

None.

COMPLY: V1.6. 2/23/2017 2:48 RESULTS:

Effective dose equivalent: 7.3 mrem/yr.

Effective dose equivalent: 7.3 mrem/yr due to Iodine.

      • Failed at level 3.

This facility is NOT in COMPLIANCE (1).

Please send this report to your regional EPA office.

You may contact your regional EPA office to determine further action.

(1) You may comply at a higher level.

                    • END OF COMPLIANCE REPORT **********

MicroShield 9.07 Microsoft (9.07-0000)

Date By Checked Filename Run Date Run Time Duration Rectangular_sourceFHA.msd February 24, 2017 9:28:03 AM 00:00:00 Project Info Case Title gaseous_source1 Description Case 1 Geometry 13 - Rectangular Volume Source Dimensions Length 1.2e+3 cm (40 ft 0.0 in)

Width 914.4 cm (30 ft)

Height 914.4 cm (30 ft)

Dose Points A

X Y

Z

  1. 1 1.2e+3 cm (41 ft 0.0 in) 457.2 cm (15 ft) 457.2 cm (15 ft)
  1. 2 1.6e+3 cm (51 ft) 457.2 cm (15 ft) 457.2 cm (15 ft)

Shields Shield N Dimension Material Density Source 3.60e+04 ft³ Air

.00122 Shield 1 1.0 ft Concrete 2.35 Air Gap Air

.00122 Source Input: Grouping Method - Standard Indices Number of Groups: 25 Lower Energy Cutoff:.015 Photons <.015: Included Library: Grove Nuclide Ci Bq

µCi/cm³ Bq/cm³ I-129 1.8990e-010 7.0263e+000 1.8628e-013 6.8925e-009 I-130 3.5060e-013 1.2972e-002 3.4393e-016 1.2725e-011 I-131 1.8720e-002 6.9264e+008 1.8364e-005 6.7945e-001 I-132 6.0750e-004 2.2478e+007 5.9594e-007 2.2050e-002 I-133 1.1450e-008 4.2365e+002 1.1232e-011 4.1558e-007 I-135 1.0410e-008 3.8517e+002 1.0212e-011 3.7784e-007 Kr-85 1.7500e-004 6.4750e+006 1.7167e-007 6.3517e-003 Kr-85m 2.2410e-009 8.2917e+001 2.1983e-012 8.1339e-008 Kr-88 5.8250e-009 2.1553e+002 5.7141e-012 2.1142e-007 Xe-133 1.3900e-002 5.1430e+008 1.3635e-005 5.0451e-001 Xe-133m 8.1760e-007 3.0251e+004 8.0204e-010 2.9675e-005 Xe-135 1.0860e-008 4.0182e+002 1.0653e-011 3.9417e-007 Xe-135m 1.3440e-009 4.9728e+001 1.3184e-012 4.8781e-008 Buildup: The material reference is Shield 1 Integration Parameters X Direction 10 Y Direction 20 Z Direction 20 Page 1 of 2 Case Summary of gaseous_source1 2/24/17 file:///C:/Program%20Files%20(x86)/MicroShield%209/Examples/CaseFiles/HTML/Rectang...

Results - Dose Point # 1 - (41.001,15,15) ft Energy (MeV)

Activity (Photons/sec)

Fluence Rate MeV/cm²/sec No Buildup Fluence Rate MeV/cm²/sec With Buildup Exposure Rate mR/hr No Buildup Exposure Rate mR/hr With Buildup Absorbed Dose Rate mrad/hr No Buildup Absorbed Dose Rate mrad/hr With Buildup Absorbed Dose Rate mGy/hr No Buildup Absorbed Dose Rate mGy/hr With Buildup 0.015 3.541e+07 1.373e-255 1.484e-27 1.177e-256 1.273e-28 1.028e-256 1.111e-28 1.028e-258 1.111e-30 0.03 2.796e+08 1.452e-37 4.076e-26 1.439e-39 4.040e-28 1.256e-39 3.527e-28 1.256e-41 3.527e-30 0.04 5.284e-01 5.412e-28 2.195e-27 2.393e-30 9.709e-30 2.090e-30 8.476e-30 2.090e-32 8.476e-32 0.08 2.069e+08 3.191e-07 7.908e-06 5.049e-10 1.251e-08 4.408e-10 1.092e-08 4.408e-12 1.092e-10 0.1 4.251e-01 8.001e-15 2.963e-13 1.224e-17 4.532e-16 1.069e-17 3.957e-16 1.069e-19 3.957e-18 0.15 5.332e+04 1.577e-08 7.773e-07 2.596e-11 1.280e-09 2.266e-11 1.117e-09 2.266e-13 1.117e-11 0.2 2.235e+06 2.787e-06 1.332e-04 4.920e-09 2.351e-07 4.295e-09 2.052e-07 4.295e-11 2.052e-09 0.3 4.581e+07 3.437e-04 1.229e-02 6.520e-07 2.332e-05 5.692e-07 2.036e-05 5.692e-09 2.036e-07 0.4 5.627e+08 1.396e-02 3.678e-01 2.721e-05 7.166e-04 2.375e-05 6.256e-04 2.375e-07 6.256e-06 0.5 7.863e+06 4.778e-04 9.656e-03 9.379e-07 1.895e-05 8.188e-07 1.655e-05 8.188e-09 1.655e-07 0.6 8.053e+07 9.949e-03 1.605e-01 1.942e-05 3.134e-04 1.695e-05 2.736e-04 1.695e-07 2.736e-06 0.8 3.380e+07 1.233e-02 1.406e-01 2.345e-05 2.674e-04 2.047e-05 2.334e-04 2.047e-07 2.334e-06 1.0 6.586e+06 5.384e-03 4.729e-02 9.925e-06 8.716e-05 8.665e-06 7.609e-05 8.665e-08 7.609e-07 1.5 3.467e+06 1.126e-02 6.394e-02 1.894e-05 1.076e-04 1.653e-05 9.391e-05 1.653e-07 9.391e-07 2.0 7.389e+05 5.819e-03 2.550e-02 8.999e-06 3.943e-05 7.856e-06 3.442e-05 7.856e-08 3.442e-07 3.0 1.663e+00 3.968e-08 1.268e-07 5.383e-11 1.720e-10 4.700e-11 1.501e-10 4.700e-13 1.501e-12 Totals 1.266e+09 5.952e-02 8.277e-01 1.095e-04 1.574e-03 9.562e-05 1.374e-03 9.562e-07 1.374e-05 Results - Dose Point # 2 - (51,15,15) ft Energy (MeV)

Activity (Photons/sec)

Fluence Rate MeV/cm²/sec No Buildup Fluence Rate MeV/cm²/sec With Buildup Exposure Rate mR/hr No Buildup Exposure Rate mR/hr With Buildup Absorbed Dose Rate mrad/hr No Buildup Absorbed Dose Rate mrad/hr With Buildup Absorbed Dose Rate mGy/hr No Buildup Absorbed Dose Rate mGy/hr With Buildup 0.015 3.541e+07 7.773e-256 5.670e-28 6.667e-257 4.864e-29 5.820e-257 4.246e-29 5.820e-259 4.246e-31 0.03 2.796e+08 1.264e-37 1.558e-26 1.253e-39 1.544e-28 1.094e-39 1.348e-28 1.094e-41 1.348e-30 0.04 5.284e-01 4.805e-28 1.950e-27 2.125e-30 8.623e-30 1.855e-30 7.528e-30 1.855e-32 7.528e-32 0.08 2.069e+08 2.715e-07 6.704e-06 4.296e-10 1.061e-08 3.751e-10 9.261e-09 3.751e-12 9.261e-11 0.1 4.251e-01 6.712e-15 2.467e-13 1.027e-17 3.774e-16 8.964e-18 3.295e-16 8.964e-20 3.295e-18 0.15 5.332e+04 1.298e-08 6.305e-07 2.138e-11 1.038e-09 1.866e-11 9.063e-10 1.866e-13 9.063e-12 0.2 2.235e+06 2.270e-06 1.063e-04 4.006e-09 1.876e-07 3.497e-09 1.638e-07 3.497e-11 1.638e-09 0.3 4.581e+07 2.754e-04 9.594e-03 5.223e-07 1.820e-05 4.560e-07 1.589e-05 4.560e-09 1.589e-07 0.4 5.627e+08 1.104e-02 2.823e-01 2.151e-05 5.500e-04 1.878e-05 4.802e-04 1.878e-07 4.802e-06 0.5 7.863e+06 3.734e-04 7.309e-03 7.330e-07 1.435e-05 6.399e-07 1.253e-05 6.399e-09 1.253e-07 0.6 8.053e+07 7.696e-03 1.200e-01 1.502e-05 2.343e-04 1.311e-05 2.045e-04 1.311e-07 2.045e-06 0.8 3.380e+07 9.365e-03 1.030e-01 1.781e-05 1.959e-04 1.555e-05 1.710e-04 1.555e-07 1.710e-06 1.0 6.586e+06 4.026e-03 3.405e-02 7.422e-06 6.276e-05 6.479e-06 5.479e-05 6.479e-08 5.479e-07 1.5 3.467e+06 8.148e-03 4.442e-02 1.371e-05 7.474e-05 1.197e-05 6.525e-05 1.197e-07 6.525e-07 2.0 7.389e+05 4.109e-03 1.725e-02 6.354e-06 2.668e-05 5.547e-06 2.329e-05 5.547e-08 2.329e-07 3.0 1.663e+00 2.702e-08 8.259e-08 3.665e-11 1.120e-10 3.200e-11 9.782e-11 3.200e-13 9.782e-13 Totals 1.266e+09 4.503e-02 6.180e-01 8.309e-05 1.177e-03 7.254e-05 1.028e-03 7.254e-07 1.028e-05 Page 2 of 2 Case Summary of gaseous_source1 2/24/17 file:///C:/Program%20Files%20(x86)/MicroShield%209/Examples/CaseFiles/HTML/Rectang...

MicroShield 9.07 Microsoft (9.07-0000)

Date By Checked Filename Run Date Run Time Duration Rectangular_sourceMHA.msd February 24, 2017 9:00:13 AM 00:00:00 Project Info Case Title gaseous_source1 Description Case 1 Geometry 13 - Rectangular Volume Source Dimensions Length 1.2e+3 cm (40 ft 0.0 in)

Width 914.4 cm (30 ft)

Height 914.4 cm (30 ft)

Dose Points A

X Y

Z

  1. 1 1.2e+3 cm (41 ft 0.0 in) 457.2 cm (15 ft) 457.2 cm (15 ft)
  1. 2 1.6e+3 cm (51 ft) 457.2 cm (15 ft) 457.2 cm (15 ft)

Shields Shield N Dimension Material Density Source 3.60e+04 ft³ Air

.00122 Shield 1 1.0 ft Concrete 2.35 Air Gap Air

.00122 Source Input: Grouping Method - Standard Indices Number of Groups: 25 Lower Energy Cutoff:.015 Photons <.015: Included Library: Grove Nuclide Ci Bq

µCi/cm³ Bq/cm³ I-129 2.6590e-009 9.8383e+001 2.6084e-012 9.6510e-008 I-130 4.9080e-012 1.8160e-001 4.8146e-015 1.7814e-010 I-131 2.6200e-001 9.6940e+009 2.5701e-004 9.5095e+000 I-132 8.5050e-003 3.1469e+008 8.3431e-006 3.0869e-001 I-133 1.6030e-007 5.9311e+003 1.5725e-010 5.8182e-006 I-135 1.4580e-007 5.3946e+003 1.4302e-010 5.2919e-006 Kr-85 2.4510e-003 9.0687e+007 2.4043e-006 8.8961e-002 Kr-85m 3.1380e-008 1.1611e+003 3.0783e-011 1.1390e-006 Kr-88 8.1560e-008 3.0177e+003 8.0007e-011 2.9603e-006 Xe-133 1.9460e-001 7.2002e+009 1.9090e-004 7.0631e+000 Xe-133m 1.1450e-005 4.2365e+005 1.1232e-008 4.1558e-004 Xe-135 1.5210e-007 5.6277e+003 1.4920e-010 5.5206e-006 Xe-135m 1.8810e-008 6.9597e+002 1.8452e-011 6.8272e-007 Buildup: The material reference is Shield 1 Integration Parameters X Direction 10 Y Direction 20 Z Direction 20 Page 1 of 2 Case Summary of gaseous_source1 2/24/17 file:///C:/Program%20Files%20(x86)/MicroShield%209/Examples/CaseFiles/HTML/Rectang...

Results - Dose Point # 1 - (41.001,15,15) ft Energy (MeV)

Activity (Photons/sec)

Fluence Rate MeV/cm²/sec No Buildup Fluence Rate MeV/cm²/sec With Buildup Exposure Rate mR/hr No Buildup Exposure Rate mR/hr With Buildup Absorbed Dose Rate mrad/hr No Buildup Absorbed Dose Rate mrad/hr With Buildup Absorbed Dose Rate mGy/hr No Buildup Absorbed Dose Rate mGy/hr With Buildup 0.015 4.958e+08 1.922e-254 2.077e-26 1.648e-255 1.781e-27 1.439e-255 1.555e-27 1.439e-257 1.555e-29 0.03 3.915e+09 2.033e-36 5.707e-25 2.015e-38 5.656e-27 1.759e-38 4.937e-27 1.759e-40 4.937e-29 0.04 7.398e+00 7.578e-27 3.074e-26 3.351e-29 1.359e-28 2.926e-29 1.187e-28 2.926e-31 1.187e-30 0.08 2.896e+09 4.467e-06 1.107e-04 7.068e-09 1.752e-07 6.171e-09 1.529e-07 6.171e-11 1.529e-09 0.1 5.952e+00 1.120e-13 4.148e-12 1.714e-16 6.346e-15 1.496e-16 5.540e-15 1.496e-18 5.540e-17 0.15 7.464e+05 2.207e-07 1.088e-05 3.635e-10 1.792e-08 3.173e-10 1.564e-08 3.173e-12 1.564e-10 0.2 3.128e+07 3.901e-05 1.864e-03 6.886e-08 3.290e-06 6.011e-08 2.872e-06 6.011e-10 2.872e-08 0.3 6.412e+08 4.811e-03 1.720e-01 9.125e-06 3.264e-04 7.966e-06 2.849e-04 7.966e-08 2.849e-06 0.4 7.875e+09 1.954e-01 5.147e+00 3.808e-04 1.003e-02 3.324e-04 8.755e-03 3.324e-06 8.755e-05 0.5 1.101e+08 6.689e-03 1.352e-01 1.313e-05 2.653e-04 1.146e-05 2.316e-04 1.146e-07 2.316e-06 0.6 1.127e+09 1.393e-01 2.247e+00 2.718e-04 4.386e-03 2.373e-04 3.829e-03 2.373e-06 3.829e-05 0.8 4.731e+08 1.726e-01 1.968e+00 3.283e-04 3.743e-03 2.866e-04 3.268e-03 2.866e-06 3.268e-05 1.0 9.221e+07 7.538e-02 6.620e-01 1.390e-04 1.220e-03 1.213e-04 1.065e-03 1.213e-06 1.065e-05 1.5 4.854e+07 1.576e-01 8.951e-01 2.651e-04 1.506e-03 2.314e-04 1.315e-03 2.314e-06 1.315e-05 2.0 1.035e+07 8.147e-02 3.570e-01 1.260e-04 5.520e-04 1.100e-04 4.819e-04 1.100e-06 4.819e-06 3.0 2.328e+01 5.556e-07 1.775e-06 7.538e-10 2.408e-09 6.580e-10 2.102e-09 6.580e-12 2.102e-11 Totals 1.772e+10 8.332e-01 1.159e+01 1.533e-03 2.203e-02 1.339e-03 1.923e-02 1.339e-05 1.923e-04 Results - Dose Point # 2 - (51,15,15) ft Energy (MeV)

Activity (Photons/sec)

Fluence Rate MeV/cm²/sec No Buildup Fluence Rate MeV/cm²/sec With Buildup Exposure Rate mR/hr No Buildup Exposure Rate mR/hr With Buildup Absorbed Dose Rate mrad/hr No Buildup Absorbed Dose Rate mrad/hr With Buildup Absorbed Dose Rate mGy/hr No Buildup Absorbed Dose Rate mGy/hr With Buildup 0.015 4.958e+08 1.088e-254 7.938e-27 9.334e-256 6.809e-28 8.148e-256 5.944e-28 8.148e-258 5.944e-30 0.03 3.915e+09 1.770e-36 2.181e-25 1.754e-38 2.162e-27 1.531e-38 1.887e-27 1.531e-40 1.887e-29 0.04 7.398e+00 6.729e-27 2.730e-26 2.976e-29 1.207e-28 2.598e-29 1.054e-28 2.598e-31 1.054e-30 0.08 2.896e+09 3.801e-06 9.385e-05 6.015e-09 1.485e-07 5.251e-09 1.297e-07 5.251e-11 1.297e-09 0.1 5.952e+00 9.398e-14 3.454e-12 1.438e-16 5.284e-15 1.255e-16 4.613e-15 1.255e-18 4.613e-17 0.15 7.464e+05 1.817e-07 8.826e-06 2.993e-10 1.453e-08 2.612e-10 1.269e-08 2.612e-12 1.269e-10 0.2 3.128e+07 3.177e-05 1.488e-03 5.607e-08 2.626e-06 4.895e-08 2.292e-06 4.895e-10 2.292e-08 0.3 6.412e+08 3.854e-03 1.343e-01 7.310e-06 2.547e-04 6.382e-06 2.224e-04 6.382e-08 2.224e-06 0.4 7.875e+09 1.545e-01 3.951e+00 3.011e-04 7.698e-03 2.628e-04 6.720e-03 2.628e-06 6.720e-05 0.5 1.101e+08 5.228e-03 1.023e-01 1.026e-05 2.008e-04 8.958e-06 1.753e-04 8.958e-08 1.753e-06 0.6 1.127e+09 1.077e-01 1.680e+00 2.103e-04 3.279e-03 1.836e-04 2.863e-03 1.836e-06 2.863e-05 0.8 4.731e+08 1.311e-01 1.442e+00 2.494e-04 2.742e-03 2.177e-04 2.394e-03 2.177e-06 2.394e-05 1.0 9.221e+07 5.637e-02 4.767e-01 1.039e-04 8.786e-04 9.071e-05 7.671e-04 9.071e-07 7.671e-06 1.5 4.854e+07 1.141e-01 6.219e-01 1.919e-04 1.046e-03 1.675e-04 9.135e-04 1.675e-06 9.135e-06 2.0 1.035e+07 5.752e-02 2.415e-01 8.895e-05 3.735e-04 7.765e-05 3.260e-04 7.765e-07 3.260e-06 3.0 2.328e+01 3.783e-07 1.156e-06 5.132e-10 1.569e-09 4.480e-10 1.370e-09 4.480e-12 1.370e-11 Totals 1.772e+10 6.304e-01 8.651e+00 1.163e-03 1.648e-02 1.015e-03 1.438e-02 1.015e-05 1.438e-04 Page 2 of 2 Case Summary of gaseous_source1 2/24/17 file:///C:/Program%20Files%20(x86)/MicroShield%209/Examples/CaseFiles/HTML/Rectang...