05000298/LER-2016-008, Regarding Purchase and Installation of Incorrect Actuator Results in a Condition Prohibited by Technical Specifications
| ML17025A072 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 01/05/2017 |
| From: | Higginbotham K Nebraska Public Power District (NPPD) |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NLS2017001 LER 16-008-00 | |
| Download: ML17025A072 (4) | |
| Event date: | |
|---|---|
| Report date: | |
| Reporting criterion: | 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(ii) 10 CFR 50.73(a)(2)(ix)(A) 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 2982016008R00 - NRC Website | |
text
H Nebraska Public Power District Alwa)'s there when )'OU need us NLS2017001 January 5, 2017 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555-0001
Subject:
Licensee Event Report No. 2016-008-00 Cooper Nuclear Station, Docket No. 50-298, DPR-46
Dear Sir or Madam:
The purpose of this correspondence is to forward Licensee Event Report 2016-008-00.
There are no new commitments contained in this letter.
Sincerely, K6~bofuam Vice President Nuclear-Chief Nuclear Officer
/jo Attachment: Licensee Event Report 2016-008-00 cc:
Regional Administrator w/attachment USNRC - Region IV Cooper Project Manager w/attachment USNRC - NRR Plant Licensing Branch IV Senior Resident Inspector w/attachment USNRC-CNS SRAB Administrator w/attachment NPG Distribution w/attachment INPO Records Center w/attachment via ICES entry SORC Chairman w/attachment CNS Records w/attachment COOPER NUCLEAR STATION P.O. Box 98 /Brownville, NE 68321-0098 Telephone: (402) 825-3811 /Fax: (402) 825-5211 www.nppd.com
NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BYOMB: NO. 3150-0104 EXPIRES: 10/31/2018 (11-2015)
, the NRG may not conduct or sponsor, and a person is not required to respond to, the information collection.
- 3. PAGE Cooper Nuclear Station 05000298 1of3
- 4. TITLE Purchase and Installation of Incorrect Actuator Results in a Condition Prohibited by Technical Specifications
- 5. EVENT DATE
- 6. LER NUMBER
- 7. REPORT DATE
- 8. OTHER FACILITIES INVOLVED YEAR 'SEQUENTIAL' REV FACILITY NAME DOCKET MONTH DAY YEAR NO.
MONTH DAY YEAR 05000 NUMBER FACILITY NAME DOCKET 11 08 2016 2016 -
008 -
00 01 05 2017 05000
- 9. OPERATING MODE
- 11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)
D 20.2201(b)
D 20.2203(a)(3)(i)
D 50. 73(a)(2)(ii)(A)
D 50.73(a)(2)(viii)(A) 1 D 20.2201(d)
D 20.2203(a)(3)(ii) 0 50.73(a)(2)(ii)(B)
D 50.73(a)(2)(viii)(B)
D 20.2203(a)(1)
D, 20.2203(a)(4)
D 50.73(a)(2)(ii)
D 50.73(a)(2)(ix)(A)
D 20.2203(a)(2)(i)
D 50.36(c)(1 )(i)(A)
D 50. 73(a)(2)(iv)(A)
D 50. 73(a)(2)(x)
D 20.2203(a)(2)(ii) 0 50.36(c)(1 )(ii)(A)
D 50.73(a)(2)(v)(A)
D 73.71(a)(4)
- 10. POWER LEVEL D 20.2203(a)(2)(iii)
D 50.36(c)(2)
D 50.73(a)(2)(v)(B)
D 73.71(a)(5)
D 20.2203(a)(2)(iv)
D 50.46(a)(3)(ii)
D 50.73(a)(2)(v)(C)
D 73.77(a)(1) 010 D 20.2203(a)(2)(v) 0 50. 73(a)(2)(i)(A)
D 50. 73(a)(2)(v)(D)
D 73.77(a)(2)(i)
D 20.2203(a)(2)(vi)
~ 50. 73(a)(2)(i)(B)
D 50. 73(a)(2)(vii)
D 73. 77(a)(2)(ii) 0 50.73(a)(2)(i)(C) 0 OTHER Specify in Abstract below or in =
PLANT STATUS SEQUENTIAL NUMBER
- - 008 REV NO.
- - 00 Cooper Nuclear Station (CNS) was in Mode 1, Power Operation, at approximately 10 percent power, at the time of the event.
BACKGROUND The Reactor Core Isolation Cooling (RCIC) [EllS:BN] system provides makeup water to the reactor pressure vessel (RPV) [EllS:RPV] following an RPV isolation in order to prevent the release of radioactive materials to the environs as a result of inadequate core cooling.
The RCIC system consists of a steam driven turbine-pump unit [EllS:TRB, P], piping, and valves [EllS:V]
to provide steam to the turbine, as well as piping and valves to transfer water from the suction sources to the core via the Feedwater [EllS:SJ] system line, where the coolant is distributed within the RPV. The RCIC system pump supply is normally aligned to the Emergency Condensate Storage Tanks. The pump discharge is normally isolated and valve operation is required to align in either RPV injection mode or test return mode. Upon receipt of an initiation signal, the RCIC turbine accelerates to provide a specified pump flow. As the RCIC flow increases, the turbine control valve (EllS:FCV] is automatically adjusted to maintain the required design flow.
RCIC is required to be operable during Modes 1, 2 and 3 with reactor steam dome pressure > 150 psig, since RCIC is the primary non-emergency core cooling system water source for core cooling when the RPV is isolated and pressurized.
RCIC-AOV-PCV23 is a 1" pressure controlled globe valve located on the RCIC pump discharge line to the RCIC lube oil cooler. This valve has an air operated actuator which regulates the pressure of the cooling water based on the output of its controller, RCIC-PC-23. The valve works as a pressure reducing orifice to maintain the pressure in the lube oil cooling line below 60 psig to prevent over pressurizing the cooling circuit. Upon a loss of air to the valve operator a spring within the actuator will force the valve open. The actuator includes a travel stop, which is designed to prevent over-pressurization of the cooling circuit by limiting the distance the valve can open.
EVENT DESCRIPTION
On November 8, 2016, at 11 :27 hours, CNS Operators declared RCIC inoperable for surveillance testing and entered Technical Specification (TS) Limiting Condition for Operation (LCO) 3.5.3, Condition A.
Subsequently at 11 :41 hours, Operations declared RCIC inoperable due to a water leak from the lube oiler cooler lower flange.
During investigation it was determined that valve RCIC-AOV-PCV23, which was replaced during Refueling Outage 29, was full open causing excessive cooling water pressure to the lube oil cooler. Initial examination revealed that the actuator was supplied with a_ closed travel stop instead of the required open travel stop. This travel stop prevents over-pressurization of the cooling circuit by limiting the opening stroke distance of RCIC-AOV-PCV23. The purchase order for the replacement valve and actuator did not contain a part description stating a travel stop was required.
NRG FORM 366 (06-2016)
NRC FORM 366 (11-2015)
U.S. NUCLEAR REGULATORY COMMISSION LICENSEE EVENT REPORT (LER)
(See Page 2 for required number of digits/characters for each block)
(See NUREG-1022, R 3 for instruction and guidance for completing this form http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1022/r3/)
Page 3of3 APPROVED BYOMB: NO. 3150-0104 EXPIRES: 10/31/2018 Estimated burden per response to comply with this mandatory collection request: 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />.
Reported lessons learned are incorporated into the licensing process and fed back to industry. Send comments regarding burden estimate to the FOIA, Privacy and Information Collections Branch (T-5 F53), U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail to lnfocollects.Resource@nrc.gov, and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington, DC 20503. If a means used to impose an infonmation collection does not display a currently valid OMB control number, the NRG may not conduct or sponsor, and a person is not required to respond to, the information collection.
- 3. LER NUMBER YEAR SEQUENTIAL REV Cooper Nuclear Station 298 NUMBER NO.
05000-2016
- - 008
- - 00 NARRATIVE The work order was revised to fabricate and install an open travel stop. On November 10, 2016, following valve modification, RCIC passed surveillance testing, was declared operable, and TS LCO 3.5.3, Condition A, was exited.
BASIS FOR REPORT This event is reportable in accordance with 10 CFR 50.73(a)(2)(i)(B) as any operation or condition which was prohibited by Technical Specifications, because RCIC was inoperable during the entry into the Mode of Applicability.
SAFETY SIGNIFICANCE
There were no actual safety consequences associated with this event. The potential safety consequences of this event were minimal due to the limited duration the condition existed and all Emergency Core Cooling Systems remained operable or available throughout the event. The RGIC system is designed to inject water into the reactor vessel during isolated conditions and is not considered an Emergency Core Cooling System. The total duration of inoperability, including the time prior to discovery of the condition was less than the 14 day Technical Specification Completion Time. During the time period of inoperability, Emergency Core Cooling Systems (High Pressure Coolant Injection, Automatic Depressurization System, Core Spray, and Low Pressure Coolant Injection) were operable or available and would have adequately responded to reactor vessel isolation and design basis events.
CAUSE
The root cause evaluation determined that the correct air operated valve was not purchased because the material master purchase order text and associated drawing didn't detail the requirement of an open travel stop.
CORRECTIVE ACTIONS
To prevent recurrence, CNS will revise the material master purchase order text to state that the valve includes a travel stop in the open direction to limit valve travel. In addition, the drawing will be modified to show the correct travel stop with a note emphasizing the design function of the travel stop.
PREVIOUS EVENTS There have been no events reported in the past three years related to RCIC being declared inoperable.
NRC FORM 366 (06-2016)