{{#Wiki_filter:,--------G 10 3 r .. 02-590 (C-7) 1 TO 12" VENT HDR.-PT5 1/2" TO SPENT RESIN TANK 302-691 (F-1 BLEED TANK 302-690 (E-6) rn woL.=-072 PRESSURIZER LOOP 302-671 (H-4' RETURN r FROM LITHIUM HYDROXIDE PUMP b, SEE DWG. 302-671 G-4 1/2" ,..-. DI I 302 670 (E 6) ).---FROM HYDRAZINE PUMP r 1/2" ,..-. .302-670 (E-6) ' ' I ' I c B A L __ _ FROM BORIC ACID 302-670 (D-3 FROM DEBORATING DEMIN I 302-692 (C-10) t: IE> MU-V49 10 MU-V211 3" OUTSIDE 2 1/2' 3/8" S-111 MU-V166A 9 MU-V6A (NOTE 12) --0 .-1 2 1/2" L ___ _ MU-V8 MU-V54A ._ ' 3/4" ._' 3/4" MU-V9 MU-V166B (NOTE 13) MU-V115 MU-V204A I SEE NOTE 3 I I 3" 2 1/2" 9 1" 2 1/2" 8 SIGHT GLASS Fl-285 4 TO VENT HOR. 302-690 (C-7) 7 3/4" S-1 I S-11 MU-V105 ! ! z"__, 4" 2 1/2" MU-V6B MLI-V70B (NOTE 12) 2 1/2" F.C. --0 -1 2 1/2" 1 MU-V110 MU-V204B I SEE NOTE 3 I MAKEUP & PURIFICATION ,... ..,. FILTERS 2 1/2" MU-V150 S-1 S-11 :t .. MU-V55A 2 1/2" ¥ ' ------:-1 3/4" I I I * ' I FLUSHING ] ,... v'1s2 !__£, CONN MU-DELAY s: :::i 3/4 CALIBRATION TAP MU-V161A _...__ RM L1; MU-V151 CALIBRATION ) 1/2" TAP MU-V1618 MU-V160B MU-V57A 2 1/2 rolro :b'.: g y 6 MU-V109B MU-V98 2 1/2" 1 1/2 I MU-V99 2 1/2" BLOCK ORIFICE 1: rMU1\ E.D. F.C. ,f MU-V978 MU-V5 (NOTE 9) R 2 F.D. TO VENT HDR. PT-6 302-690 (C-7 Fl 142 L SIGHT [t> GLASS 3/4" MU-V109A RB 4" I" cW ' =i5 e :::ou ml 1" 25g:; 'f g 2" 4" MU-V101B 4" 3" 1 1/2" 4"
"+i MU-V104 SEE NOTE 3 ' -----4"---------, I MU-V48 I I I DRAIN :Lr I MU-V47 I 4" MU-V46I MAKEUP I S-111 S-1 ,1, I 1" TANK I I MU-T-1 I I MU-RV-1 (SEE NOTE 16) I SEE NOTE 3 I 1" I L
_____ _________ _J 3/4" MU-V225 1" rt> i 1Mu-v 226 N-3 s-11 j c,s-11 TO VENT HOR. PT-6 I 2 ,. 2., GP-150-2A GP-150-ZR < 302 690 (c 7) I i 8 7 302-694 (G-5) TO WASTE GAS COMPRESSOR 1" 6 5 ,--- 1" 0 I 1" 5 AUX. BLOG. SUMP 302-719 (C-4) 4 MU-V26 (NOTE 10) ISO. TEST 3/4" S-1 I S-111 RB I LETDOWN COOLER MU-C-18 ' I ' g DRAIN 302-719 (0-8) NOTES 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. 4. SYSTEM DESIGN BASIS -SEISMIC CLASS I. 5. VALVES MU-V1 THRU 39 BY B & W. 7.
ERECTION ONLY) INSTRUMENTS & INSTRUMENT LINES -CLASS C OPEN ENO VENTS & DRAINS COMMERCIALLY CLEAN @ RESIN ADD -SEE DWG, 302-670 (0 RECLAIMED WATER -SEE DWG. 302-670 @ NUCLEAR SERVICES -SEE OWG. 302-610 8. VENT CONNECTIONS ARE CAPPED WHEN VENT RIGS NOT IN PLACE. 9. SEE OWG. 302279 SHS.1&11 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 10.SEE DWG. 302279 SH.2 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 11.SEE DWG. 302279 SH.3 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 12.SEE DWG. 302279 SHA FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 13.SEE DWG. 302279 SH.9 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 14.SEE DWG. 302279 SH.10 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 15.SEE DWG. 302279 SH.1 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 16.SEE DWG. 302661 FOR ADDITIONAL SYSTEM PIPING TO THE MAKE-UP TANK. 4 3 MU-V138 3/4" 3 TO VENT HDR. 302-694 (G.:.6) 1 1/2 2 VENT _3/4" MU-V154 2 1/2" MU-V113 MU-V96D 302-003 302-002 302-001 MU-V178D 1" COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 2 1 47 IC,D,E-21 REVISED TO INCORPORATE ECR-13-00237 REV. 1 1R.C.SYSTEM LOOP"B" 302-650 (A-3) COLD LEG MU-V184A R.C. PUMP A MU-V183A SEAL # 2 SEAL INLET PRESSURE MU-V184B R.C. PUMP B MU-V183B SEAL # 2 SEAL INLET PRESSURE l" MU-V184C R.C. PUMP c MU-V183C SEAL 2 SEAL 1" MU-V184D R.C. PUMP D <Rll> MU-V183D SEAL # 2 SEAL INLET PRESSURE MU-V176A R.C. PUMP 302-650 CONTROLLED E3LEEDOFF MU-V176B R.C. PUMP B 302-650 (B-7) CONTROLLED BLEEDOFF MU-V176C 302-650 (8-4 CONTROLLED BLEEDOFF 1"_11/2"[[!ill R.C. PUMP D 302-650 (D-4) MU-V177D MU-V330 CONTROLLED BLEEDOFF D c w R j Cad FOeName:302660 R47 I§ Do I ExelonlP NOT RE\'lSE IT MANUALLY Nuclear MAKEUP & PURIFICATION FLOW DIAGRAM I A 302-660 I 47 SCALE: NONE _ _______ _J ,--------G 10 3 r .. 02-590 (C-7) 1 TO 12" VENT HDR.-PT5 1/2" TO SPENT RESIN TANK 302-691 (F-1 BLEED TANK 302-690 (E-6) rn woL.=-072 PRESSURIZER LOOP 302-671 (H-4' RETURN r FROM LITHIUM HYDROXIDE PUMP b, SEE DWG. 302-671 G-4 1/2" ,..-. DI I 302 670 (E 6) ).---FROM HYDRAZINE PUMP r 1/2" ,..-. .302-670 (E-6) ' ' I ' I c B A L __ _ FROM BORIC ACID 302-670 (D-3 FROM DEBORATING DEMIN I 302-692 (C-10) t: IE> MU-V49 10 MU-V211 3" OUTSIDE 2 1/2' 3/8" S-111 MU-V166A 9 MU-V6A (NOTE 12) --0 .-1 2 1/2" L ___ _ MU-V8 MU-V54A ._ ' 3/4" ._' 3/4" MU-V9 MU-V166B (NOTE 13) MU-V115 MU-V204A I SEE NOTE 3 I I 3" 2 1/2" 9 1" 2 1/2" 8 SIGHT GLASS Fl-285 4 TO VENT HOR. 302-690 (C-7) 7 3/4" S-1 I S-11 MU-V105 ! ! z"__, 4" 2 1/2" MU-V6B MLI-V70B (NOTE 12) 2 1/2" F.C. --0 -1 2 1/2" 1 MU-V110 MU-V204B I SEE NOTE 3 I MAKEUP & PURIFICATION ,... ..,. FILTERS 2 1/2" MU-V150 S-1 S-11 :t .. MU-V55A 2 1/2" ¥ ' ------:-1 3/4" I I I * ' I FLUSHING ] ,... v'1s2 !__£, CONN MU-DELAY s: :::i 3/4 CALIBRATION TAP MU-V161A _...__ RM L1; MU-V151 CALIBRATION ) 1/2" TAP MU-V1618 MU-V160B MU-V57A 2 1/2 rolro :b'.: g y 6 MU-V109B MU-V98 2 1/2" 1 1/2 I MU-V99 2 1/2" BLOCK ORIFICE 1: rMU1\ E.D. F.C. ,f MU-V978 MU-V5 (NOTE 9) R 2 F.D. TO VENT HDR. PT-6 302-690 (C-7 Fl 142 L SIGHT [t> GLASS 3/4" MU-V109A RB 4" I" cW ' =i5 e :::ou ml 1" 25g:; 'f g 2" 4" MU-V101B 4" 3" 1 1/2" 4"
"+i MU-V104 SEE NOTE 3 ' -----4"---------, I MU-V48 I I I DRAIN :Lr I MU-V47 I 4" MU-V46I MAKEUP I S-111 S-1 ,1, I 1" TANK I I MU-T-1 I I MU-RV-1 (SEE NOTE 16) I SEE NOTE 3 I 1" I L
_____ _________ _J 3/4" MU-V225 1" rt> i 1Mu-v 226 N-3 s-11 j c,s-11 TO VENT HOR. PT-6 I 2 ,. 2., GP-150-2A GP-150-ZR < 302 690 (c 7) I i 8 7 302-694 (G-5) TO WASTE GAS COMPRESSOR 1" 6 5 ,--- 1" 0 I 1" 5 AUX. BLOG. SUMP 302-719 (C-4) 4 MU-V26 (NOTE 10) ISO. TEST 3/4" S-1 I S-111 RB I LETDOWN COOLER MU-C-18 ' I ' g DRAIN 302-719 (0-8) NOTES 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. 4. SYSTEM DESIGN BASIS -SEISMIC CLASS I. 5. VALVES MU-V1 THRU 39 BY B & W. 7.
ERECTION ONLY) INSTRUMENTS & INSTRUMENT LINES -CLASS C OPEN ENO VENTS & DRAINS COMMERCIALLY CLEAN @ RESIN ADD -SEE DWG, 302-670 (0 RECLAIMED WATER -SEE DWG. 302-670 @ NUCLEAR SERVICES -SEE OWG. 302-610 8. VENT CONNECTIONS ARE CAPPED WHEN VENT RIGS NOT IN PLACE. 9. SEE OWG. 302279 SHS.1&11 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 10.SEE DWG. 302279 SH.2 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 11.SEE DWG. 302279 SH.3 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 12.SEE DWG. 302279 SHA FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 13.SEE DWG. 302279 SH.9 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 14.SEE DWG. 302279 SH.10 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 15.SEE DWG. 302279 SH.1 FOR INSTRUMENT AIR DETAILS TO VALVE OPERATOR 16.SEE DWG. 302661 FOR ADDITIONAL SYSTEM PIPING TO THE MAKE-UP TANK. 4 3 MU-V138 3/4" 3 TO VENT HDR. 302-694 (G.:.6) 1 1/2 2 VENT _3/4" MU-V154 2 1/2" MU-V113 MU-V96D 302-003 302-002 302-001 MU-V178D 1" COMPONENT & SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM 2 1 47 IC,D,E-21 REVISED TO INCORPORATE ECR-13-00237 REV. 1 1R.C.SYSTEM LOOP"B" 302-650 (A-3) COLD LEG MU-V184A R.C. PUMP A MU-V183A SEAL # 2 SEAL INLET PRESSURE MU-V184B R.C. PUMP B MU-V183B SEAL # 2 SEAL INLET PRESSURE l" MU-V184C R.C. PUMP c MU-V183C SEAL 2 SEAL 1" MU-V184D R.C. PUMP D <Rll> MU-V183D SEAL # 2 SEAL INLET PRESSURE MU-V176A R.C. PUMP 302-650 CONTROLLED E3LEEDOFF MU-V176B R.C. PUMP B 302-650 (B-7) CONTROLLED BLEEDOFF MU-V176C 302-650 (8-4 CONTROLLED BLEEDOFF 1"_11/2"[[!ill R.C. PUMP D 302-650 (D-4) MU-V177D MU-V330 CONTROLLED BLEEDOFF D c w R j Cad FOeName:302660 R47 I§ Do I ExelonlP NOT RE\'lSE IT MANUALLY Nuclear MAKEUP & PURIFICATION FLOW DIAGRAM I A 302-660 I 47 SCALE: NONE _ _______ _J}}