I I H G F E D c B A FROM INDUSTRIAL COOLER AH-C-18 302-845(F-5) 8 RB-V2 "!!.' 3/8" OD WATER c1ii PUMPS ES AH-P-2A & 28 IM 302-845(G-5 8 8" 7 ,-----RB-V3A 6" t" DRAIN RB-V8A 302-848 (F=2fl 6" 8" I 6" 1" VENT V9 4" 6" I 1" .A.
DRAIN 6 REACTOR COMPARTMENT COOLING COILS L .A.RB-V11
- 1" DR ---------RB---7 6 5 1N VENT RR-V23A 1" VENT RR-V25A 1" VENT RR-V238 1" VENT RR-V25B t" VENT RR-V23C 1" VENT RR-V25C 5 l#jll 1#412 --RB 1D 1 2 4 ES 12" M .. RR-V3A RR-V14A y ES 12" M RR-V38 RR-V14B y 12" RR-V3C RR-V14C y 'i' 4 3 12" 20" 12" VENT RR-V13 16" VENT RR-V16 RR-V4D 16" 3 2 REVISIONS
""' OESCRIPTION 14 IVARIESIREVISED TO INCORPORATE ECR-14-00031 REV. 2 7 1 RR-1 V27A I 2" I I 12* RR-P-1A R.B. EMERGENCY COOLING PUMPS L SERVICE WAlER SCREEN AND PUMP HOUSE -----------------
RR-P-18 __ _J NOTES: 5* EF-V5 EF-V4 TO EFP SUCTION 302-082 (D-8 TO EF-V3 1. VALVE POSITION SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE 14 4. SPECTACLE FLANGE IS NORMALLY IN THE OPEN POSITION.
H G F E D c I "' 0 I Cod File Nome ; 302611 R14 302-003 302-002 302-001 DWG. NO. COMPONENT
& SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM REFERENCES 2 CAUTION THIS DRAWING IS ALSO BEING REVISED BY ECR-13-00556
!!! THIS IS A COMPUTER GENERATED DRA'MNG DO NOT REVISE IT MANUALLY Exelon. Nuclear I"""""'""-'" ";!."I REACTOR BLDG NORMAL & ":l!r:£,;;;l hhr EMERGENCY COOLING WATER SYS DESIGtl w DlllE FLOW DIAGRAM TMl-1 302-611 14 NONE w I A I I H G F E D c B A FROM INDUSTRIAL COOLER AH-C-18 302-845(F-5) 8 RB-V2 "!!.' 3/8" OD WATER c1ii PUMPS ES AH-P-2A & 28 IM 302-845(G-5 8 8" 7 ,-----RB-V3A 6" t" DRAIN RB-V8A 302-848 (F=2fl 6" 8" I 6" 1" VENT V9 4" 6" I 1" .A.
DRAIN 6 REACTOR COMPARTMENT COOLING COILS L .A.RB-V11
- 1" DR ---------RB---7 6 5 1N VENT RR-V23A 1" VENT RR-V25A 1" VENT RR-V238 1" VENT RR-V25B t" VENT RR-V23C 1" VENT RR-V25C 5 l#jll 1#412 --RB 1D 1 2 4 ES 12" M .. RR-V3A RR-V14A y ES 12" M RR-V38 RR-V14B y 12" RR-V3C RR-V14C y 'i' 4 3 12" 20" 12" VENT RR-V13 16" VENT RR-V16 RR-V4D 16" 3 2 REVISIONS
""' OESCRIPTION 14 IVARIESIREVISED TO INCORPORATE ECR-14-00031 REV. 2 7 1 RR-1 V27A I 2" I I 12* RR-P-1A R.B. EMERGENCY COOLING PUMPS L SERVICE WAlER SCREEN AND PUMP HOUSE -----------------
RR-P-18 __ _J NOTES: 5* EF-V5 EF-V4 TO EFP SUCTION 302-082 (D-8 TO EF-V3 1. VALVE POSITION SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE 14 4. SPECTACLE FLANGE IS NORMALLY IN THE OPEN POSITION.
H G F E D c I "' 0 I Cod File Nome ; 302611 R14 302-003 302-002 302-001 DWG. NO. COMPONENT
& SYS ID INDEX SYMBOLS INSTRUMENTATION SYMBOLS FLOW DIAGRAM REFERENCES 2 CAUTION THIS DRAWING IS ALSO BEING REVISED BY ECR-13-00556
!!! THIS IS A COMPUTER GENERATED DRA'MNG DO NOT REVISE IT MANUALLY Exelon. Nuclear I"""""'""-'" ";!."I REACTOR BLDG NORMAL & ":l!r:£,;;;l hhr EMERGENCY COOLING WATER SYS DESIGtl w DlllE FLOW DIAGRAM TMl-1 302-611 14 NONE w I A