I I H I G I I I I I I 'E I Ie B ----------------------
1 8 7 6 FS-H-Z8 FS-H-29 FS-H-30 2FS-V113 2FS-V124 2FS-V141 6" 6" 6" 2FS-Vl11A FROM 2FS-V110A 12" 18" 12" PIV #51 1302 231 SH.1 (F 1)
... l ..
.. --.. -.. -----... -.. BLDG 42 2FS-V626 FROM 2FS-Vl10B 302-231 SH.' (0-1) 8 " 12" 2FS-V123 "'" PIV #58 1'"" 6" 2FS-V114 FS-H-33 FS-H-31 10" 12" 2FS-V118 6" FS-H-32 2FS-V116 6" 2F$-Vl 22 2FS-V138 10" '" 2FS-V140 PlY #154 12" 2FS-V12S4 12" " 2FS-V119 PlY #55 1"
...... --'2."---.. 10."-IPI")62 6" 0 2FS-V1304 (BURIED) BLDG 43 'C7 2FS-V129 '" PlY #60 12" 2FS-Vl061 2FS-V170 12" 18" 12" 6" h:' 6" 6" /' 2FS-V169 ,/ 2FS-V144 I 2FS-V621 WAREHOUSE
- 2 2FS-V121 FS-H-34 6" 2FS-V134 FS-H-39 FS-H-38 2FS-\f135 2FS-V112B 6" PlY #54 / 7 "'" 2FS-V130 PlY #61 6" 2FS-V133 12" FS -H-36 2FS-V131 6" FS-H-37 2FS-V127 2FS-V1D52 6" 2FS-V128 10" 12" 6 5 14 12" I WASTE HNDLG & PKG FACILITY 2FS-V1284 2FS-V1285 FS-H-35 FS-V505 6" 2FS-V1272 4" 2FS-V1273 . 2FS-V1274 RESPIRATOR CLEANING FACILITY 12" 5 TO DRAIN HEADER 4 DRAIN 2FS-V1055
-TRIM VALVE SCHEMATIC DETAil " FS-V506 4" FS-V522 FLAMMABLE LIQUIDS STORAGE BUILDING 6" ..n FS-H-41 2FS-Vl056 2FS-Vl054 2FS-Vl053 6" J" . 2FS-Vl055 2FS-V1268 WAREHOUSE ADMIN #3 BLDG '------4 3 2FS-T-6 ; NO 3 14 302-003 302-002 2 1 DESCRIPllON 14 VARIES REVISED TO INCORPORATE ECR-09-00207 REV. 1. DRAIN RETARDING CHAMBER (UNTAGGED)
DELUGE VALVE 2FS-V1529 2FS-V1268 2FS-V1528
__ 2FS-V673 TO DRAIN HEADER 2" u DRAIN STRAINER (UNTAGGED) 2c;>-V1268
-TRIM VALVE SCHEMATIC DETAil 2rS-V1826 TO DRAIN HEADER WATER ALARM "WTOR STRAINER 3/4" u DRAIN 2FS-V1274
-TRIM VALVE SCHEMATIC DETAil NOTES 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CON1ROLLED BY GMS2. 4.
& EQUIPMENT NUMBERS Will HAVE 5. FOR ADDITIONAL NOlES AND lEGEND SEE 302-231 H G F I E o e COMPONENT
& SYSTEM INDEX SYMBOLS INSTRUMENTAll0N I I THIS IS A COMPUTER Ex I t'lOT REVlSE IT MANUALLY Nuclear ,Y FIRE SERVICE WATER FLOW DIAGRAM A 2 I I H I G I I I I I I 'E I Ie B ----------------------
1 8 7 6 FS-H-Z8 FS-H-29 FS-H-30 2FS-V113 2FS-V124 2FS-V141 6" 6" 6" 2FS-Vl11A FROM 2FS-V110A 12" 18" 12" PIV #51 1302 231 SH.1 (F 1)
... l ..
.. --.. -.. -----... -.. BLDG 42 2FS-V626 FROM 2FS-Vl10B 302-231 SH.' (0-1) 8 " 12" 2FS-V123 "'" PIV #58 1'"" 6" 2FS-V114 FS-H-33 FS-H-31 10" 12" 2FS-V118 6" FS-H-32 2FS-V116 6" 2F$-Vl 22 2FS-V138 10" '" 2FS-V140 PlY #154 12" 2FS-V12S4 12" " 2FS-V119 PlY #55 1"
...... --'2."---.. 10."-IPI")62 6" 0 2FS-V1304 (BURIED) BLDG 43 'C7 2FS-V129 '" PlY #60 12" 2FS-Vl061 2FS-V170 12" 18" 12" 6" h:' 6" 6" /' 2FS-V169 ,/ 2FS-V144 I 2FS-V621 WAREHOUSE
- 2 2FS-V121 FS-H-34 6" 2FS-V134 FS-H-39 FS-H-38 2FS-\f135 2FS-V112B 6" PlY #54 / 7 "'" 2FS-V130 PlY #61 6" 2FS-V133 12" FS -H-36 2FS-V131 6" FS-H-37 2FS-V127 2FS-V1D52 6" 2FS-V128 10" 12" 6 5 14 12" I WASTE HNDLG & PKG FACILITY 2FS-V1284 2FS-V1285 FS-H-35 FS-V505 6" 2FS-V1272 4" 2FS-V1273 . 2FS-V1274 RESPIRATOR CLEANING FACILITY 12" 5 TO DRAIN HEADER 4 DRAIN 2FS-V1055
-TRIM VALVE SCHEMATIC DETAil " FS-V506 4" FS-V522 FLAMMABLE LIQUIDS STORAGE BUILDING 6" ..n FS-H-41 2FS-Vl056 2FS-Vl054 2FS-Vl053 6" J" . 2FS-Vl055 2FS-V1268 WAREHOUSE ADMIN #3 BLDG '------4 3 2FS-T-6 ; NO 3 14 302-003 302-002 2 1 DESCRIPllON 14 VARIES REVISED TO INCORPORATE ECR-09-00207 REV. 1. DRAIN RETARDING CHAMBER (UNTAGGED)
DELUGE VALVE 2FS-V1529 2FS-V1268 2FS-V1528
__ 2FS-V673 TO DRAIN HEADER 2" u DRAIN STRAINER (UNTAGGED) 2c;>-V1268
-TRIM VALVE SCHEMATIC DETAil 2rS-V1826 TO DRAIN HEADER WATER ALARM "WTOR STRAINER 3/4" u DRAIN 2FS-V1274
-TRIM VALVE SCHEMATIC DETAil NOTES 1. VALVE POSITIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.
- 2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES ARE NOMINAL AND FOR REFERENCE ONLY. ACTUAL DATA CON1ROLLED BY GMS2. 4.
& EQUIPMENT NUMBERS Will HAVE 5. FOR ADDITIONAL NOlES AND lEGEND SEE 302-231 H G F I E o e COMPONENT
& SYSTEM INDEX SYMBOLS INSTRUMENTAll0N I I THIS IS A COMPUTER Ex I t'lOT REVlSE IT MANUALLY Nuclear ,Y FIRE SERVICE WATER FLOW DIAGRAM A 2