ML16130A272

From kanterella
Jump to navigation Jump to search
302003, Sheet Na, Rev 039, Component and System Identification Index
ML16130A272
Person / Time
Site: Crane 
(DPR-050)
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16130A272 (1)


Text

1-----------------------------------------------------------------------------------------------------------------------------------,

8 I

7 I

6 I

5 4

I 3

I 2

I 1

H G

F I

'E I jo I

I c

!e I

I I

IA SYSTEM S/PRE AH AH AH AH AH AH AH AH AH AH VENTILATION-REACTOR, AUXIWARY AND FUEL HANDLING BUILDINGS VENTILATION-REACTOR, AUXILUARY AND FUEL HANDLING BUILDINGS ESF VENTILATION SYSTEM "A" FUEL HANDLING AREA ESF VENTILATION SYSTEM "B" FUEL HANDLING AREA VENTILATION-AUXILUARY AND FUEL HANDLING BUILDINGS VENTILATION-AUXILLIARY AND FUEL HANDLING BUILDINGS VENTILATION-CONTROL BUILDING AND MACHINE SHOP VENTILATION-CONTROL BUILDING AND MACHINE SHOP VENTILATION-SERVICE BUILDING VENTILATION TURBINE BUILDINGS AND OUT BUILDINGS AH VENTILATION-PROCESSING CENTER AH HEATING VENTILATION AND AIR CONDITIONING-OPERATIONS SUPPORT FACILITY AH HEATING VENTILATION AND AIR CONDITIONING-OPERATIONS SUPPORT FACILITY AH STA. BLACKOUT DIESEL GEN. H & V FOR EG-Y-4 AS AUXILLIARY STEAM AS AUXILLIARY STEAM UNITS 1 & 2 CROSS CONNECT BS REACTOR BUILDING SPRAY CA CHEMICAL ADDITION CA CHEMICAL ADDITION CA LIQUID SAMPLING CA POST ACCIDENT REACTOR COOLANT SAMPLING CA GAS SAMPLING CC CHEMICAL CLEANING-TURBINE PLANT CC OSTG CHEMICAL CLEANING CF CORE FLOORING CH CHILLED WATER-SERVICE BUILDING CH CHILLED WATER-CONTROL BUILDING CL CIRCULATING WATER BIOCIDE AND CHEMICAL FEED CL COOLING WATER CHLORINATION UNITS 1 AND 2 CM CONTAINMENT ATMOSPHERE POST ACCIDENT SAMPLING CD CONDENSATE CD MISCELLANEOUS CONDENSATE DRAINS CD POWDEX WASTE PROCESSING STATION AND DRUMMING STATION CD TURBINE BUILDING SUMP WATER STORAGE CD POWDEX CONDENSATE FILTER UNITS CD FEEDPUMP SHAFT SEALS AND LEAKOFF CD CONDENSATE SEAL WATER Fl DIAG 302-831 302-832 302-833 SH 1 302-833 SH 2

  • 302-840 302-841 302-842 SH t 302-842 SH 2 302-843 302-844 302-849 302-851 302-852 302-881 302-051 302-052 3D2-712 302-669 302-670 302-671 302-673 302-675 302-190 302-196 302-711 302-846 302-847 302-173 302-174 302-721 302-101 302-102 302-106 302-159 302-172 302-281 302-352 CO POWDEX CONDENSATE FILTER UNITS 302-172 CW CIRCULATING WATER 302-201 CW CONDENSER CLEANING 302-204 DC DECAY HEAT CLOSED CYCLE-COOLING WATER 302-645 OF DIESEL FUEL OIL TO "ups" DIESEL GENERATOR AND DIESEL FUEL OIL 302-284 TO SUBSTATION DIESEL A &: B.

OF EMERGENCY DIESEL GENERATOR SERVICES-DIESEL FUEL 302-351 OF STA.BLACKOUT DIESEL GEN.DIESEL FUEL SYS FOR EG-Y-4 DH DECAY HEAT REMOVAL DH DECAY HEAT REMOVAL MOTOR AND PUMP REMOTE OILING DO DOMESTIC WATER SEWAGE TREATMENT PLANT DO DOMESTIC WATER HEADERS AND END USERS DO DOMESTIC WATER HEADERS AND END USERS DO DOMESTIC WATER UNITS I &: II HEADERS AND END USERS DO DOMESTIC WATER UNITS I &: II HEADERS AND END USERS DO DOMESTIC WATER UNIT II HEADERS AND END USERS DO DOMESTIC WATER OPERATIONS SUPPORT FACILITY DO DOMESTIC WATER INDUSTRIAL WASTE TREATMENT BUILDING OR DECAY HEAT RIVER WATER SYSTEM DR DECAY HEAT RIVER WATER PUMOS LUBRICATION SYSTEM OW DEMINERALIZED WATER SYSTEM EFW EMERGENCY FEEDWATER EG EMERGENCY DIESEL GENERATOR SERVICES AIR SYSTEM EG EMERGENCY DIESEL GENERATOR SERVICES LUBE OIL-FUEL OIL AIR START EG DIESEL GENERATOR SVCS.-LUBE Oil, FUEL OIL, AIR START EG EMERGENCY DIESEL GENERATOR JACKET AND AIR COOLER COOLANT SYSTEM GEAR BOX LUBE OIL SYSTEM EG STA.BLACKOUT DIESEL GEN. INST. & STARTING AIR FOR EG-Y-4 EG STA.BLACKOUT DIESEL GEN. LUBE OIL SYS. FOR EG-Y-4 EG STA.BLACKOUT DIESEL GEN. JACKET COOLANT SYS.

EHC TURBINE EHC SYSTEM EHC TURBINE EHC SYSTEM EHC TURBINE EHC SYSTEM EX H.P. TURBINE EXTRACTION STEAM EX L.P. TURBINE EXTRACTION STEAM EX L.P. EXTRACTION STEAM SECONDARY PERFORMANCE MONITORING FB PENETRATION FLUID BLOCK FO AUXILLIARY BOILER FUEL Oil FO FUEL OIL UNLOADING STATIONS TO STORAGE TANKS FS FIRE SERVICE WATER YARD HEADER AND OUT BLDG END USERS FS FIRE SERVICE WATER IN PLANT HEADER AND END USERS FS FIRE SERVICE WATER FS FIRE SERVICE WATER MISC. SCHEMATIC DETAILS FS FIRE PROTECTION SERVICE WATER SYSTEM OPERATIONS SUPPORT FS FIRE PROTECTION HALON SYSTEM SUPPORT FACILITY FS FIRE SERVICE WATER UNIT II HEADERS FS STA.BLACKOUT DIESEL GEN.COOL WTR.SYS.FOR EG-Y-4 FS

  • CHARCOAL SPRAY SYSTEM REACTOR BUILDING FS OPERATIONAL SCHEMATIC FIRE PROTECTION FW FEEDWATER FW FEEDWATER INSTRUMENTATION FX FLEX FEEDWATER SYSTEM FX FLEX RCS & SPENT FUEL MAKE-UP SYSTEM GS TURBINE GLAND STEAM & DRAINS GSC GENERATOR STATOR COOLANT SYSTEM GW GLYCOL WATER OPERATIONS SUPPORT FACILITY GW GLYCOL WATER OPERATIONS SUPPORT FACILITY HD FEEDWATER HEATER DRAINS HG GENERATOR HYRDOGEN GAS AND VENTS HM POST ACCIDENT MONITORING CONTAINMENT HYDROGEN HM NUCLEAR PLANT H2 SUPPLY HP HYDROGEN PURGE DISCHARGE SYSTEM HP RADIATION MONITORING & SAMPLE PANEL DETAIL HR HYDROGEN RECOMBINER HV FEEDWATER HEATER VENTS RELIEFS AND MISCELLANOUS DRAINS IA INSTRUMENT AIR INTERMEDIA.TE BUILDING HEADERS ANO END USERS IA INSTRUMENT AIR INTERMEDIATE BUILDING HEADERS ANO END USERS IA INSTRUMENT AIR FLOW DIA.TURBINE BLOG.INSTRUMENT AJR COMP.

IA INSTRUMENT & STATION SERVICE AIR IA BACKUP INSTRUMENT AIR IA EFW & MS 2 HOUR BACKUP INSTRUMENT AIR IA INSTRUMENT AIR TURBINE AND OUT BUILDING HEADERS IA INSTRUMENT AIR 2 HOUR BACKUP INSTRUMENT AIR CHARGING COMPRESSOR 8

7 302-355 302-640 302-641 302-153 302-158 SH 1 302-158 SH 2 302-15B SH 3 302-158 SH 4 302-15B SH 5 302-160 302-166 302-202 302-203 302-163 302-082 302-351 302-284 302-353 302-.354 302-356 302-358 302-359 302-302 SH 1 302-302 SH 2 302-302 SH 3 302-041 302-042 302-043 302-705 302-283 302-283 302-231 SH 1 302-231 SH 2 302-231 SH 3 302-231 SH 4 302-232 302-233 302-234 302-357 302-848 M232 302-081 302-032 302-083 302-663 302-141 302-304 302-834 302-835 302-111 302-301 302-674 302-720 302-721 302-730 302-722 302-112 302-268 302-269 302-270 302-271 302-272 302-273 302-275 302-276 39 6

S/PRE IA IA IA IA IA IA IA IA IA IA SYSTEM INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR AUXILUARY BUILDING HEADERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IC INTERMEDIATE COOLING IW INDUSTRIAL WASTE TREATMENT SYSTEM IW INDUSTRIAL WASTE FILTER SYSTEM IW INDUSTRIAL WASTE TREATMENT SYS/FILTER SYS-JNST & SERV. AIR SUPPLY IWT CYQE MAKEUP DEMINERAl..IZERS SHT 1

!WT CYQE MAKEUP DEMINERALIZERS SHT 2 LO FEED PUMP TURBINE "A" DRIVE TURBINE LUBE OIL SYSTEM LO FEED PUMP TURBINE "B" DRIVE TURBINE WBE Oil SYSTEM LO TURBINE LUBE OIL PURIFICATION & TRANSFER SYSTEMSTEM LO MAIN TURBINE-GENERATOR LUBE OIL SYSTEM LO MAlN TURBINE-GENERATOR LUBE Oil SYSTEM LO MAIN TURBINE-GENERATOR LUBE OIL SYSTEM LR CONTAINMENT VESSEL LEAK RATE TEST MO MOISTURE SEPERATOR MS MAIN STEAM MS MAIN STEAM TO RELIEF VAlVE POST SUPPORTS MS MAIN STEAM INSTRUMENTATION MS MAIN STEAM MISCELLEANOUS TRAPS MU MAKEUP & PURIFICATION MU MAKEUP & PURIFICATION NI NITROGEN BLANKETING FOR FEEDWATER HEATERS NI NUQEAR PLANT NITROGEN SUPPLY & HYDROGEN SUPPLY NI OSTG l.P. NITROGEN MANIFOLDS NR NUCLEAR SERVICES RIVER WATER NR NUCLEAR SERVICES LUBRICATION SYSTEM NS NUCLEAR SERVICES CLOSED CYCLE COOLING WATER PC PENETRATION COOLING-REACTOR BUILDING PG GENERATOR GAS & VENTS PP PENETRATION PRESSURIZATION QUADRANTS I ANO II PP PENETRATION PRESSURIZATION QUADRANTS Ill AND IV RB INDUSTRIAL COOLER SYSTEM RC REACTOR COOLANT SYSTEM SH 1 RC REACTOR COOLANT SYSTEM SH 2 RC REACTOR COOLANT PUMP MOTOR LUBE Oil SYSTEM RR REACTOR BUILDING EMERGENCY COOLING RR REACTOR BUILDING EMERGENCY COOLING LUBRICATION SYSTEM RR REACTOR BUILDING EMERGENCY COOLING WATER STSTEM F.D.

SA STATION SERVICE AIR SC SECONDARY SERVICES COOLING SYSTEM CLOSED CYCLE TURBINE BUILDING SUMP WATER STORAGE FL DIAG 302-277 SH 1 302-277 SH 2 302-277 SH 3 302-277 SH 4 302-277 SH 5 302-277 SH 6 302-277 SH 7 302-277 SH 8 302-277 SH 9 302-277 SH 10 302-277 SH 11 302-277 SH 12 302-277 SH 13 302-278 302-279 SH 1 302-279 SH 2 302-279 SH 3 302-279 SH 4 302-279 SH 5 302-279 SH 6 302-279 SH 7 302-279 SH 8 302-279 SH 9 302-279 SH 10 302-279 SH 11 302-620 302-166 302-167 302-168 302-162 302-163 302-280 SH 1 302-2BO SH 2 302-291 302-305 302-306 302-307 302-725 302-111 302-011 302-012 302-032 302-121 302-660 302-661 302-198 302-720 302-723 302-202 302-203 302-610 302-708 302-301 302-706 302-707 302-845 3D2-650 302-651 302-652 302-202 302-203 302-611 302-271 302-221 302-159 SD SD SD SD SUMP DRAINS TO INDUSTRIAL WASTE TREATMENT 302-165 AIR TUNNEL INTERMEDIATE BLDG & CIRCULATING WATER HOUSE SUMPS 302-352 OSTG SECONDARY SIDE PORTABLE RECIRC. SYSTEM 302-718 SD SUMP PUMP & DRAINAGE SYS REACTOR AND AUX BLDG SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SF SPENT FUEL COOLING SYSTEM SF SPENT FUEL AND FUEL TRANSFER CANAL LEAK DETECTION SO GENERATOR SEAL Oil SYSTEM SO SHAFT SEALING SYSTEM SR SECONDARY SERVICE RIVER WATER SR SECONDARY SERVICE LUBRICATION SYSTEM SS SAMPLING AUXILLIARY BOILER SS TURBINE PLANT SAMPLING SS TURBINE PL.ANT SAMPLING VA CONDENSER AIR REMOVAL SW SCREEN HOUSE VENT-RIVER WATER SW SCREEN WASH AND SLUICE SYSTEM 10 MAIN TURBINE STOP & CONTROL VALVE DRAINS ID FEED PUMP TURBINE DRAINS TI-JS MAIN TURBINE EXHAUST HOOD SPRAY SYSTEM FLOW DIAGRAM VA CONDENSER AIR REMOVAL VA MAIN/AUX.COND.AIR REMOVAL MAIN VAC.PMP.LUBE Oil CLG.,AUX.VAC.PMP.SEAL WTR.CLG.

VT DECAY HEAT AND CORE FLOOD CHECK VALVE TEST SYSTEM WDG WASTE DISPOSAL GAS WDG WASTE GAS COMPRESSORS 302-719 302-151 302-152 302-153 302-630 302-728 302-301 302-303 302-202 302-203 302-175 302-181 302-182 302-131 302-202 302-203 302-011 3D2-121 302-308 302-131 302-132 302-713 302-694 302-696 WDL WDL WDL WOL WOL WOL WT WT WT WT WT WT LIQUID WASTE DISPOSAL-R.C. BLEED TKS & MISC WASTE COLLECTION 302-690 LIQUID WASTE DISPOSAL-FILTER DEMINERALIZERS 302-691 LIQUID WASTE DISPOSAL-WASTE OIL TRANSFER/RECJRC SYSTEM 302-692 LIQUID WASTE DISPOSAL-SPENT RESIN COLLECTION 302-693 LIQUID WASTE EVAPORATORS.REACTOR COOLANT AND MISC WASTE 302-695 SUMP PUMP AND DRAINAGE SYSTE~ (REACTOR AND AUXILLIARY BLDGS) 302-719 CYCLE MAKEUP PRETREATMENT & FILTERED WATER 302-161 CYCLE MAKEUP DEMINERALIZERS SH 1 CYCLE MAKEUP OEMINERALIZERS SH 2 CONDENSATE CHEMICAL FEED CIRCULATING WATER-ACID ADDITION AUXILLIARY BOILER-CHEMICAL FEED WT FILTERED WATER-PRETREATMENT BUILDING WT FILTERED WATER-INDUSTRIAL WASTE TREATMENT BUILDING WT FILTERED WATER-UNITS I & II HEADERS ANO END USERS COMPOSITE STARTUP 5

302-162 302-163 302-171 302-173 302-175 302-161 302-166 302-169 302-031 NO.

DWG. NO.

TillE REFERENCES 4

3 L-----------------------------------------------------------------------------------------------------

REV1SIONS REV I ZONE 39 IN/A !REVISED TO INCORPORATE ECR-14-00032 REV. 2 COMPONENT ABBREVATIONS w

CRANE, HOISTS, MONORAILS, ELEVA TORS AND MECHANICAL TRANSPORTATION BOILER COOLER OR HEAT EXCHANGER DRAIN EXHAUSTER OR FAN FILTER GAS ANALYZER STEAM "GENERATOR FEED WATER HEATER

. DEMINERALIZER LUSE. OIL CONOJTIONE~

MIXER MANIFOLD PUMP OR COMPRESSOR DRYER RELIEF VALl/F.

SAMPLE OR STRAINER TANK TURSI NE VALVE Y

MlSCELLEANOUS BAILER, WASTE DRUMMING EQUIPMENT, SPENT FUEL STORAGE RACKS.

EVAPORATOR ES DENOTES ENGINEERED SAFEGUARD SP DENOTES SECONDARY PLANT EXAMPLE

~

LETTERS USED TO DESIGNATE SYSTEM LETTERS USED TO DESIGNATE COMPONENT NUMBER TO DESIGNATE SIMILAR COMPONENTS x

~(L IN SYSTEM LETTER TO DESIGNATE A,B OR C LOOP IF REQUIRED LETTER TO DESIGNATE IDENTICAL COMPONENTS IF NOTES:

MORE THAN ONE HD-V2B WOULD BE HEATER DRAIN

~~~?N VALVE (V) NUMBER 2 (2) ON B FEED WATER Cad File Nome :302003-R39 H

G F

E D

c II

~

0 1--~~~~~~~~~~~---1~

2 THIS IS A COMPUTER GENERATED DRAW"ING DO NOT REVISE IT MANUALLY Exelon.

Nuclear COMPONENT & SYSTEM IDENTIFICATION INDEX TMl-1 302-003 SHEET I"*

NIA 39 SCALE: NfA z

)>

A I,.

I I

I


. ~--~_J-

1-----------------------------------------------------------------------------------------------------------------------------------,

8 I

7 I

6 I

5 4

I 3

I 2

I 1

H G

F I

'E I jo I

I c

!e I

I I

IA SYSTEM S/PRE AH AH AH AH AH AH AH AH AH AH VENTILATION-REACTOR, AUXIWARY AND FUEL HANDLING BUILDINGS VENTILATION-REACTOR, AUXILUARY AND FUEL HANDLING BUILDINGS ESF VENTILATION SYSTEM "A" FUEL HANDLING AREA ESF VENTILATION SYSTEM "B" FUEL HANDLING AREA VENTILATION-AUXILUARY AND FUEL HANDLING BUILDINGS VENTILATION-AUXILLIARY AND FUEL HANDLING BUILDINGS VENTILATION-CONTROL BUILDING AND MACHINE SHOP VENTILATION-CONTROL BUILDING AND MACHINE SHOP VENTILATION-SERVICE BUILDING VENTILATION TURBINE BUILDINGS AND OUT BUILDINGS AH VENTILATION-PROCESSING CENTER AH HEATING VENTILATION AND AIR CONDITIONING-OPERATIONS SUPPORT FACILITY AH HEATING VENTILATION AND AIR CONDITIONING-OPERATIONS SUPPORT FACILITY AH STA. BLACKOUT DIESEL GEN. H & V FOR EG-Y-4 AS AUXILLIARY STEAM AS AUXILLIARY STEAM UNITS 1 & 2 CROSS CONNECT BS REACTOR BUILDING SPRAY CA CHEMICAL ADDITION CA CHEMICAL ADDITION CA LIQUID SAMPLING CA POST ACCIDENT REACTOR COOLANT SAMPLING CA GAS SAMPLING CC CHEMICAL CLEANING-TURBINE PLANT CC OSTG CHEMICAL CLEANING CF CORE FLOORING CH CHILLED WATER-SERVICE BUILDING CH CHILLED WATER-CONTROL BUILDING CL CIRCULATING WATER BIOCIDE AND CHEMICAL FEED CL COOLING WATER CHLORINATION UNITS 1 AND 2 CM CONTAINMENT ATMOSPHERE POST ACCIDENT SAMPLING CD CONDENSATE CD MISCELLANEOUS CONDENSATE DRAINS CD POWDEX WASTE PROCESSING STATION AND DRUMMING STATION CD TURBINE BUILDING SUMP WATER STORAGE CD POWDEX CONDENSATE FILTER UNITS CD FEEDPUMP SHAFT SEALS AND LEAKOFF CD CONDENSATE SEAL WATER Fl DIAG 302-831 302-832 302-833 SH 1 302-833 SH 2

  • 302-840 302-841 302-842 SH t 302-842 SH 2 302-843 302-844 302-849 302-851 302-852 302-881 302-051 302-052 3D2-712 302-669 302-670 302-671 302-673 302-675 302-190 302-196 302-711 302-846 302-847 302-173 302-174 302-721 302-101 302-102 302-106 302-159 302-172 302-281 302-352 CO POWDEX CONDENSATE FILTER UNITS 302-172 CW CIRCULATING WATER 302-201 CW CONDENSER CLEANING 302-204 DC DECAY HEAT CLOSED CYCLE-COOLING WATER 302-645 OF DIESEL FUEL OIL TO "ups" DIESEL GENERATOR AND DIESEL FUEL OIL 302-284 TO SUBSTATION DIESEL A &: B.

OF EMERGENCY DIESEL GENERATOR SERVICES-DIESEL FUEL 302-351 OF STA.BLACKOUT DIESEL GEN.DIESEL FUEL SYS FOR EG-Y-4 DH DECAY HEAT REMOVAL DH DECAY HEAT REMOVAL MOTOR AND PUMP REMOTE OILING DO DOMESTIC WATER SEWAGE TREATMENT PLANT DO DOMESTIC WATER HEADERS AND END USERS DO DOMESTIC WATER HEADERS AND END USERS DO DOMESTIC WATER UNITS I &: II HEADERS AND END USERS DO DOMESTIC WATER UNITS I &: II HEADERS AND END USERS DO DOMESTIC WATER UNIT II HEADERS AND END USERS DO DOMESTIC WATER OPERATIONS SUPPORT FACILITY DO DOMESTIC WATER INDUSTRIAL WASTE TREATMENT BUILDING OR DECAY HEAT RIVER WATER SYSTEM DR DECAY HEAT RIVER WATER PUMOS LUBRICATION SYSTEM OW DEMINERALIZED WATER SYSTEM EFW EMERGENCY FEEDWATER EG EMERGENCY DIESEL GENERATOR SERVICES AIR SYSTEM EG EMERGENCY DIESEL GENERATOR SERVICES LUBE OIL-FUEL OIL AIR START EG DIESEL GENERATOR SVCS.-LUBE Oil, FUEL OIL, AIR START EG EMERGENCY DIESEL GENERATOR JACKET AND AIR COOLER COOLANT SYSTEM GEAR BOX LUBE OIL SYSTEM EG STA.BLACKOUT DIESEL GEN. INST. & STARTING AIR FOR EG-Y-4 EG STA.BLACKOUT DIESEL GEN. LUBE OIL SYS. FOR EG-Y-4 EG STA.BLACKOUT DIESEL GEN. JACKET COOLANT SYS.

EHC TURBINE EHC SYSTEM EHC TURBINE EHC SYSTEM EHC TURBINE EHC SYSTEM EX H.P. TURBINE EXTRACTION STEAM EX L.P. TURBINE EXTRACTION STEAM EX L.P. EXTRACTION STEAM SECONDARY PERFORMANCE MONITORING FB PENETRATION FLUID BLOCK FO AUXILLIARY BOILER FUEL Oil FO FUEL OIL UNLOADING STATIONS TO STORAGE TANKS FS FIRE SERVICE WATER YARD HEADER AND OUT BLDG END USERS FS FIRE SERVICE WATER IN PLANT HEADER AND END USERS FS FIRE SERVICE WATER FS FIRE SERVICE WATER MISC. SCHEMATIC DETAILS FS FIRE PROTECTION SERVICE WATER SYSTEM OPERATIONS SUPPORT FS FIRE PROTECTION HALON SYSTEM SUPPORT FACILITY FS FIRE SERVICE WATER UNIT II HEADERS FS STA.BLACKOUT DIESEL GEN.COOL WTR.SYS.FOR EG-Y-4 FS

  • CHARCOAL SPRAY SYSTEM REACTOR BUILDING FS OPERATIONAL SCHEMATIC FIRE PROTECTION FW FEEDWATER FW FEEDWATER INSTRUMENTATION FX FLEX FEEDWATER SYSTEM FX FLEX RCS & SPENT FUEL MAKE-UP SYSTEM GS TURBINE GLAND STEAM & DRAINS GSC GENERATOR STATOR COOLANT SYSTEM GW GLYCOL WATER OPERATIONS SUPPORT FACILITY GW GLYCOL WATER OPERATIONS SUPPORT FACILITY HD FEEDWATER HEATER DRAINS HG GENERATOR HYRDOGEN GAS AND VENTS HM POST ACCIDENT MONITORING CONTAINMENT HYDROGEN HM NUCLEAR PLANT H2 SUPPLY HP HYDROGEN PURGE DISCHARGE SYSTEM HP RADIATION MONITORING & SAMPLE PANEL DETAIL HR HYDROGEN RECOMBINER HV FEEDWATER HEATER VENTS RELIEFS AND MISCELLANOUS DRAINS IA INSTRUMENT AIR INTERMEDIA.TE BUILDING HEADERS ANO END USERS IA INSTRUMENT AIR INTERMEDIATE BUILDING HEADERS ANO END USERS IA INSTRUMENT AIR FLOW DIA.TURBINE BLOG.INSTRUMENT AJR COMP.

IA INSTRUMENT & STATION SERVICE AIR IA BACKUP INSTRUMENT AIR IA EFW & MS 2 HOUR BACKUP INSTRUMENT AIR IA INSTRUMENT AIR TURBINE AND OUT BUILDING HEADERS IA INSTRUMENT AIR 2 HOUR BACKUP INSTRUMENT AIR CHARGING COMPRESSOR 8

7 302-355 302-640 302-641 302-153 302-158 SH 1 302-158 SH 2 302-15B SH 3 302-158 SH 4 302-15B SH 5 302-160 302-166 302-202 302-203 302-163 302-082 302-351 302-284 302-353 302-.354 302-356 302-358 302-359 302-302 SH 1 302-302 SH 2 302-302 SH 3 302-041 302-042 302-043 302-705 302-283 302-283 302-231 SH 1 302-231 SH 2 302-231 SH 3 302-231 SH 4 302-232 302-233 302-234 302-357 302-848 M232 302-081 302-032 302-083 302-663 302-141 302-304 302-834 302-835 302-111 302-301 302-674 302-720 302-721 302-730 302-722 302-112 302-268 302-269 302-270 302-271 302-272 302-273 302-275 302-276 39 6

S/PRE IA IA IA IA IA IA IA IA IA IA SYSTEM INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR TURBINE BUILDING END USERS IA INSTRUMENT AIR AUXILUARY BUILDING HEADERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IA INSTRUMENT AIR AUXILLIARY BUILDING END USERS IC INTERMEDIATE COOLING IW INDUSTRIAL WASTE TREATMENT SYSTEM IW INDUSTRIAL WASTE FILTER SYSTEM IW INDUSTRIAL WASTE TREATMENT SYS/FILTER SYS-JNST & SERV. AIR SUPPLY IWT CYQE MAKEUP DEMINERAl..IZERS SHT 1

!WT CYQE MAKEUP DEMINERALIZERS SHT 2 LO FEED PUMP TURBINE "A" DRIVE TURBINE LUBE OIL SYSTEM LO FEED PUMP TURBINE "B" DRIVE TURBINE WBE Oil SYSTEM LO TURBINE LUBE OIL PURIFICATION & TRANSFER SYSTEMSTEM LO MAIN TURBINE-GENERATOR LUBE OIL SYSTEM LO MAlN TURBINE-GENERATOR LUBE Oil SYSTEM LO MAIN TURBINE-GENERATOR LUBE OIL SYSTEM LR CONTAINMENT VESSEL LEAK RATE TEST MO MOISTURE SEPERATOR MS MAIN STEAM MS MAIN STEAM TO RELIEF VAlVE POST SUPPORTS MS MAIN STEAM INSTRUMENTATION MS MAIN STEAM MISCELLEANOUS TRAPS MU MAKEUP & PURIFICATION MU MAKEUP & PURIFICATION NI NITROGEN BLANKETING FOR FEEDWATER HEATERS NI NUQEAR PLANT NITROGEN SUPPLY & HYDROGEN SUPPLY NI OSTG l.P. NITROGEN MANIFOLDS NR NUCLEAR SERVICES RIVER WATER NR NUCLEAR SERVICES LUBRICATION SYSTEM NS NUCLEAR SERVICES CLOSED CYCLE COOLING WATER PC PENETRATION COOLING-REACTOR BUILDING PG GENERATOR GAS & VENTS PP PENETRATION PRESSURIZATION QUADRANTS I ANO II PP PENETRATION PRESSURIZATION QUADRANTS Ill AND IV RB INDUSTRIAL COOLER SYSTEM RC REACTOR COOLANT SYSTEM SH 1 RC REACTOR COOLANT SYSTEM SH 2 RC REACTOR COOLANT PUMP MOTOR LUBE Oil SYSTEM RR REACTOR BUILDING EMERGENCY COOLING RR REACTOR BUILDING EMERGENCY COOLING LUBRICATION SYSTEM RR REACTOR BUILDING EMERGENCY COOLING WATER STSTEM F.D.

SA STATION SERVICE AIR SC SECONDARY SERVICES COOLING SYSTEM CLOSED CYCLE TURBINE BUILDING SUMP WATER STORAGE FL DIAG 302-277 SH 1 302-277 SH 2 302-277 SH 3 302-277 SH 4 302-277 SH 5 302-277 SH 6 302-277 SH 7 302-277 SH 8 302-277 SH 9 302-277 SH 10 302-277 SH 11 302-277 SH 12 302-277 SH 13 302-278 302-279 SH 1 302-279 SH 2 302-279 SH 3 302-279 SH 4 302-279 SH 5 302-279 SH 6 302-279 SH 7 302-279 SH 8 302-279 SH 9 302-279 SH 10 302-279 SH 11 302-620 302-166 302-167 302-168 302-162 302-163 302-280 SH 1 302-2BO SH 2 302-291 302-305 302-306 302-307 302-725 302-111 302-011 302-012 302-032 302-121 302-660 302-661 302-198 302-720 302-723 302-202 302-203 302-610 302-708 302-301 302-706 302-707 302-845 3D2-650 302-651 302-652 302-202 302-203 302-611 302-271 302-221 302-159 SD SD SD SD SUMP DRAINS TO INDUSTRIAL WASTE TREATMENT 302-165 AIR TUNNEL INTERMEDIATE BLDG & CIRCULATING WATER HOUSE SUMPS 302-352 OSTG SECONDARY SIDE PORTABLE RECIRC. SYSTEM 302-718 SD SUMP PUMP & DRAINAGE SYS REACTOR AND AUX BLDG SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SE SEWAGE TREATMENT PLANT-PLANT UPGRADING & EXPANSION SF SPENT FUEL COOLING SYSTEM SF SPENT FUEL AND FUEL TRANSFER CANAL LEAK DETECTION SO GENERATOR SEAL Oil SYSTEM SO SHAFT SEALING SYSTEM SR SECONDARY SERVICE RIVER WATER SR SECONDARY SERVICE LUBRICATION SYSTEM SS SAMPLING AUXILLIARY BOILER SS TURBINE PLANT SAMPLING SS TURBINE PL.ANT SAMPLING VA CONDENSER AIR REMOVAL SW SCREEN HOUSE VENT-RIVER WATER SW SCREEN WASH AND SLUICE SYSTEM 10 MAIN TURBINE STOP & CONTROL VALVE DRAINS ID FEED PUMP TURBINE DRAINS TI-JS MAIN TURBINE EXHAUST HOOD SPRAY SYSTEM FLOW DIAGRAM VA CONDENSER AIR REMOVAL VA MAIN/AUX.COND.AIR REMOVAL MAIN VAC.PMP.LUBE Oil CLG.,AUX.VAC.PMP.SEAL WTR.CLG.

VT DECAY HEAT AND CORE FLOOD CHECK VALVE TEST SYSTEM WDG WASTE DISPOSAL GAS WDG WASTE GAS COMPRESSORS 302-719 302-151 302-152 302-153 302-630 302-728 302-301 302-303 302-202 302-203 302-175 302-181 302-182 302-131 302-202 302-203 302-011 3D2-121 302-308 302-131 302-132 302-713 302-694 302-696 WDL WDL WDL WOL WOL WOL WT WT WT WT WT WT LIQUID WASTE DISPOSAL-R.C. BLEED TKS & MISC WASTE COLLECTION 302-690 LIQUID WASTE DISPOSAL-FILTER DEMINERALIZERS 302-691 LIQUID WASTE DISPOSAL-WASTE OIL TRANSFER/RECJRC SYSTEM 302-692 LIQUID WASTE DISPOSAL-SPENT RESIN COLLECTION 302-693 LIQUID WASTE EVAPORATORS.REACTOR COOLANT AND MISC WASTE 302-695 SUMP PUMP AND DRAINAGE SYSTE~ (REACTOR AND AUXILLIARY BLDGS) 302-719 CYCLE MAKEUP PRETREATMENT & FILTERED WATER 302-161 CYCLE MAKEUP DEMINERALIZERS SH 1 CYCLE MAKEUP OEMINERALIZERS SH 2 CONDENSATE CHEMICAL FEED CIRCULATING WATER-ACID ADDITION AUXILLIARY BOILER-CHEMICAL FEED WT FILTERED WATER-PRETREATMENT BUILDING WT FILTERED WATER-INDUSTRIAL WASTE TREATMENT BUILDING WT FILTERED WATER-UNITS I & II HEADERS ANO END USERS COMPOSITE STARTUP 5

302-162 302-163 302-171 302-173 302-175 302-161 302-166 302-169 302-031 NO.

DWG. NO.

TillE REFERENCES 4

3 L-----------------------------------------------------------------------------------------------------

REV1SIONS REV I ZONE 39 IN/A !REVISED TO INCORPORATE ECR-14-00032 REV. 2 COMPONENT ABBREVATIONS w

CRANE, HOISTS, MONORAILS, ELEVA TORS AND MECHANICAL TRANSPORTATION BOILER COOLER OR HEAT EXCHANGER DRAIN EXHAUSTER OR FAN FILTER GAS ANALYZER STEAM "GENERATOR FEED WATER HEATER

. DEMINERALIZER LUSE. OIL CONOJTIONE~

MIXER MANIFOLD PUMP OR COMPRESSOR DRYER RELIEF VALl/F.

SAMPLE OR STRAINER TANK TURSI NE VALVE Y

MlSCELLEANOUS BAILER, WASTE DRUMMING EQUIPMENT, SPENT FUEL STORAGE RACKS.

EVAPORATOR ES DENOTES ENGINEERED SAFEGUARD SP DENOTES SECONDARY PLANT EXAMPLE

~

LETTERS USED TO DESIGNATE SYSTEM LETTERS USED TO DESIGNATE COMPONENT NUMBER TO DESIGNATE SIMILAR COMPONENTS x

~(L IN SYSTEM LETTER TO DESIGNATE A,B OR C LOOP IF REQUIRED LETTER TO DESIGNATE IDENTICAL COMPONENTS IF NOTES:

MORE THAN ONE HD-V2B WOULD BE HEATER DRAIN

~~~?N VALVE (V) NUMBER 2 (2) ON B FEED WATER Cad File Nome :302003-R39 H

G F

E D

c II

~

0 1--~~~~~~~~~~~---1~

2 THIS IS A COMPUTER GENERATED DRAW"ING DO NOT REVISE IT MANUALLY Exelon.

Nuclear COMPONENT & SYSTEM IDENTIFICATION INDEX TMl-1 302-003 SHEET I"*

NIA 39 SCALE: NfA z

)>

A I,.

I I

I


. ~--~_J-