MONTHYEARML24040A0722024-02-13013 February 2024 Energy Solution Feb 13 Pubic Meeting Slides on TMI-2 Decommissioning ML20178A4202020-06-30030 June 2020 NEI Slides for June 30, 2020, Public Meeting on COVID-19 Response ML20170B0212020-06-23023 June 2020 NRC Pre-Submittal Meeting Byron Unit 2 One-Time Deferral of Reactor Pressure Vessel Head Penetration Nozzle (Rpvhpn) Inspections ML20169A5592020-06-16016 June 2020 Steam Generator License Amendment Request Pre-Submittal Meeting (NRC) - Byron Unit 2 LAR for One-Time Deferral of Steam Generator Inspections (Rev 1) ML20163A6552020-06-16016 June 2020 6-16-20 Byron Unit 2 Steam Generator License Amendment Request Pre-Submittal Meeting (NRC) - Byron Unit 2 LAR for One-Time Deferral of Steam Generator Inspections ML19157A0542019-06-0606 June 2019 Joint Annual Assessment Meeting (Webinar) for Pennsylvania Power Plants - NRC Presentation Slides ML19161A2572019-06-0404 June 2019 BWR Fleet Msv/Srv - Testing Frequency Relief Request NRC Pre-Application Meeting June 4, 2019 ML19151A6602019-05-31031 May 2019 BWR Fleet Mssv/Srv Testing Frequency Relief Request NRC Pre-Application Meeting June 4, 2019 ML19022A2002019-01-23023 January 2019 Request for Use of ASME Code Case N-879 for Exelon Nuclear Power Plants ML18347B3142018-12-19019 December 2018 Bwrvip/Asme Relief Request Discussion December 19, 2018 ML18334A2162018-11-30030 November 2018 Presentation Slides: Exelon BWR MSIV (Boiling-Water Reactor - Main Steam Isolation Valve) Leakage Optimization for NRC Pre-Submittal Meeting of December 6, 2018 ML18319A1272018-11-19019 November 2018 Slides for 11/19/18 Public Meeting - Exelon Fleet LAR for Common Language for TS 5.7 High Radiation Areas ML17142A2382017-05-25025 May 2017 OEDO-17-00280 - Briefing Package for Drop-In Visit on June 9, 2017, by Senior Management of Exelon Generation Company, LLC with Chairman Svinicki, Commissioner Baran, and Commissioner Burns ML16077A1562016-03-22022 March 2016 Fleet: Pre-application Teleconference with Exelon to Discuss a Potential License Amendment Request Regarding Operating Training Standards ML16075A3292016-03-16016 March 2016 OEDO-16-00165 - Briefing Package for Drop-In Visit on March 23, 2016, by Senior Management of Exelon Generation Company, LLC with the NRC Executive Director for Operations ML15327A0812015-11-0909 November 2015 Fall 2015 Outage Call Regarding the Steam Generator Tube Inservice Inspections - Slides ML15238B6272015-08-26026 August 2015 Case Study Overview ML14300A5452014-10-30030 October 2014 10/30/2014, Meeting Slide with NRC Regarding GL 2004-02 Close Out for Three Mile Island, Unit 1 ML13262A1492013-09-19019 September 2013 Enclosure 3- NRC Presentation Handout ML13262A1172013-08-28028 August 2013 Enclosure 4 - Scott Portzline Presentation ML12262A3352012-09-13013 September 2012 9.13.2012 TMI Alert Presentation Nreg 0654 Public Mtg ML1208701402012-03-27027 March 2012 Licensee Slides for Exelon Fleet Pre-Submittal Public Meeting 4-10-12 Licensed Operator Eligibility Requirements LAR ML12262A4762012-02-22022 February 2012 TMI Alert Portzline Presentation NUREG-0654 Public Mtg ML1202501052012-01-25025 January 2012 Licensee Slides for 1/26/12 Meeting Three Mile Island, Unit 1 - Summary of Tube to Tube Wear Identified During T1R19 (Fall 2011) ML1115901302011-06-0808 June 2011 NRC Slides - TMI Public Meeting, June 7, 2011 ML11090A0872011-04-0505 April 2011 Fire (a)(4) Tabletop Pilot Method and Results ML1007802632010-01-25025 January 2010 Presentation - Health Physics Society Mid-Year Meeting ML1007805052009-12-23023 December 2009 Executive Team Daily Brief ML1007805442009-12-0202 December 2009 Executive Team Daily Brief ML1007805412009-11-27027 November 2009 Executive Team Daily Brief ML1007805402009-11-25025 November 2009 Executive Team Daily Brief ML1007805062009-11-24024 November 2009 Executive Team Daily Brief ML0929406112009-11-0202 November 2009 Summary of Category 1 Public Meeting with Exelon to Discuss Proposed Control Rod Drive Control System License Amendment Request ML0919803632009-08-20020 August 2009 Summary of Licensing Counterparts Meeting with Exelon Generation Company, to Discuss Licensing Practices and Processes ML0913906312009-06-0404 June 2009 ACRS Meeting with the U.S. Nuclear Regulatory Commission, - June 4, 2009, Slides ML0910702242009-04-17017 April 2009 Riv Regional Administrator Presentation at Texas A&M University March 30, 2009, Three Mile Island - Impact on Safety Perspectives and Safety Belief ML0907508342009-03-16016 March 2009 Meeting Slides, Three Mile Island Annual Assessment Meeting 2008 Reactor Oversight Process ML0906302662009-02-24024 February 2009 02/24/2009 Three Mile Island Nuclear Station, Unit 1, Dseis Meeting Presentation Slides Preliminary Results of the Three Mile Island Nuclear Station, Unit 1 License Renewal Environmental Review. ML0906302652009-02-24024 February 2009 Dseis Meeting Handouts ML0826712092008-09-23023 September 2008 TMI Pre-Application Meeting - Control Rod Drive Control System Upgrade and Elimination of Axial Power Shaping Rods ML0812007842008-06-0202 June 2008 Meeting Slides, Nrc/Exelon Licensing Counterparts Meeting. ML0813301852008-05-0101 May 2008 License Renewal Environmental Scoping Meeting Handouts and Slides ML0813301832008-05-0101 May 2008 License Renewal Environmental Scoping Meeting Written Comments ML0807906742008-03-19019 March 2008 Slides, NRC Annual Performance Assessment of Three Mile Island - 2007 Reactor Oversight Program. ML0806700982008-03-0404 March 2008 License Renewal Process Overview Three Mile Island Unit 1 Public Meeting Handout 03/04/2008 ML0735507162007-12-21021 December 2007 TMI Refueling Outage Performance Summary ML0726404902007-08-14014 August 2007 TMI Intro ML0726404922007-08-14014 August 2007 TMI Tritium Update 08/07 - Slide Presentation ML0713701672007-04-30030 April 2007 Enclosure 2 (Slides) - 04/30/2007 Summary of Meeting with Amergen Energy Co., LLC, Regarding License Amendment Request Relating to the Insertion of New Area High Thermal Performance Fuel in the TMI-1 Reactor ML0710901582007-04-19019 April 2007 Aam Final Slides for Reactor Oversight Program 2006-07 Public Meeting 04/11/07 2024-02-13
[Table view] Category:Slides and Viewgraphs
MONTHYEARML24040A0722024-02-13013 February 2024 Energy Solution Feb 13 Pubic Meeting Slides on TMI-2 Decommissioning ML22301A1402022-10-28028 October 2022 1993 TMI Event - Jure Kutlesa, Security Specialist ML20178A4202020-06-30030 June 2020 NEI Slides for June 30, 2020, Public Meeting on COVID-19 Response ML20170B0212020-06-23023 June 2020 NRC Pre-Submittal Meeting Byron Unit 2 One-Time Deferral of Reactor Pressure Vessel Head Penetration Nozzle (Rpvhpn) Inspections ML20163A6552020-06-16016 June 2020 6-16-20 Byron Unit 2 Steam Generator License Amendment Request Pre-Submittal Meeting (NRC) - Byron Unit 2 LAR for One-Time Deferral of Steam Generator Inspections ML20169A5592020-06-16016 June 2020 Steam Generator License Amendment Request Pre-Submittal Meeting (NRC) - Byron Unit 2 LAR for One-Time Deferral of Steam Generator Inspections (Rev 1) ML20050H0232020-02-20020 February 2020 Presentation Slides for Meeting to Discuss Environmental Regulatory Approach to TMI-2 Decommissioning ML19157A0542019-06-0606 June 2019 Joint Annual Assessment Meeting (Webinar) for Pennsylvania Power Plants - NRC Presentation Slides ML18347B3142018-12-19019 December 2018 Bwrvip/Asme Relief Request Discussion December 19, 2018 ML18334A2162018-11-30030 November 2018 Presentation Slides: Exelon BWR MSIV (Boiling-Water Reactor - Main Steam Isolation Valve) Leakage Optimization for NRC Pre-Submittal Meeting of December 6, 2018 ML18319A1272018-11-19019 November 2018 Slides for 11/19/18 Public Meeting - Exelon Fleet LAR for Common Language for TS 5.7 High Radiation Areas ML16077A1562016-03-22022 March 2016 Fleet: Pre-application Teleconference with Exelon to Discuss a Potential License Amendment Request Regarding Operating Training Standards ML16070A1152016-03-11011 March 2016 Efforts to Improve Rulemaking Tracking and Reporting ML16006A2882016-01-0606 January 2016 Significant Operational Experience: 7 Major Industry Events with Regulatory Implications ML15327A0812015-11-0909 November 2015 Fall 2015 Outage Call Regarding the Steam Generator Tube Inservice Inspections - Slides ML14304A7832014-11-14014 November 2014 Public Meeting with the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC Regarding Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Wate ML14300A5452014-10-30030 October 2014 10/30/2014, Meeting Slide with NRC Regarding GL 2004-02 Close Out for Three Mile Island, Unit 1 ML13262A1492013-09-19019 September 2013 Enclosure 3- NRC Presentation Handout ML13262A1172013-08-28028 August 2013 Enclosure 4 - Scott Portzline Presentation ML12262A3352012-09-13013 September 2012 9.13.2012 TMI Alert Presentation Nreg 0654 Public Mtg ML12116A0482012-04-25025 April 2012 Aam ROP-12 Slides ML1208701402012-03-27027 March 2012 Licensee Slides for Exelon Fleet Pre-Submittal Public Meeting 4-10-12 Licensed Operator Eligibility Requirements LAR ML12262A4762012-02-22022 February 2012 TMI Alert Portzline Presentation NUREG-0654 Public Mtg ML1202501052012-01-25025 January 2012 Licensee Slides for 1/26/12 Meeting Three Mile Island, Unit 1 - Summary of Tube to Tube Wear Identified During T1R19 (Fall 2011) ML11221A3262011-08-0101 August 2011 521- R326C B&W Tech Cross Training - Chapter 18 Three Mile Island ML1115901302011-06-0808 June 2011 NRC Slides - TMI Public Meeting, June 7, 2011 ML13197A0522011-04-19019 April 2011 FOIA/PA-2011-0118, FOIA/PA-2011-0119, FOIA/PA-2011-0120 - Resp 111 - Partial, Group Letter Bt. Part 5 of 7 ML1007802632010-01-25025 January 2010 Presentation - Health Physics Society Mid-Year Meeting ML1007703672009-12-0707 December 2009 E-mail from J. White of USNRC to D. Screnci and J. Hawkins of USNRC, Regarding TMI NRC Slides.Ppt ML0929400522009-10-22022 October 2009 Meeting Power Uprate Meeting Slides ML0913906312009-06-0404 June 2009 ACRS Meeting with the U.S. Nuclear Regulatory Commission, - June 4, 2009, Slides ML0910702242009-04-17017 April 2009 Riv Regional Administrator Presentation at Texas A&M University March 30, 2009, Three Mile Island - Impact on Safety Perspectives and Safety Belief ML0907508342009-03-16016 March 2009 Meeting Slides, Three Mile Island Annual Assessment Meeting 2008 Reactor Oversight Process ML11216A2452008-12-0202 December 2008 0523 - R504P - Westinghouse Advanced Technology - 07.4 - Core Damaging Events ML0828805412008-10-14014 October 2008 Herbaceous Wetlands ML0826712092008-09-23023 September 2008 TMI Pre-Application Meeting - Control Rod Drive Control System Upgrade and Elimination of Axial Power Shaping Rods ML0812007842008-06-0202 June 2008 Meeting Slides, Nrc/Exelon Licensing Counterparts Meeting. ML0813301852008-05-0101 May 2008 License Renewal Environmental Scoping Meeting Handouts and Slides ML0813301832008-05-0101 May 2008 License Renewal Environmental Scoping Meeting Written Comments ML0807906742008-03-19019 March 2008 Slides, NRC Annual Performance Assessment of Three Mile Island - 2007 Reactor Oversight Program. ML0806700982008-03-0404 March 2008 License Renewal Process Overview Three Mile Island Unit 1 Public Meeting Handout 03/04/2008 ML0802501172008-01-15015 January 2008 1/15/2008 Slides from Drop-in Visit Exelon/Amergen ML0726404902007-08-14014 August 2007 TMI Intro ML0726404922007-08-14014 August 2007 TMI Tritium Update 08/07 - Slide Presentation ML0713701672007-04-30030 April 2007 Enclosure 2 (Slides) - 04/30/2007 Summary of Meeting with Amergen Energy Co., LLC, Regarding License Amendment Request Relating to the Insertion of New Area High Thermal Performance Fuel in the TMI-1 Reactor ML0710901582007-04-19019 April 2007 Aam Final Slides for Reactor Oversight Program 2006-07 Public Meeting 04/11/07 ML0726404942007-03-28028 March 2007 Unit 2 Accident - Presentation Slides ML0708513862007-03-26026 March 2007 Annual Assessment Slides for ROP 2006-07 Public Meeting on 4-11-07 ML0716601022007-03-20020 March 2007 Slides to Counterparts Meeting with Exelon to Discuss Current and Planned Licensing Activities and Process - Correction ML0607508032006-03-22022 March 2006 NRC Slide Presentation for Public Meeting Ref: Three Mile Island, Unit 1 Annual Assessment Performance CY2005 2024-02-13
[Table view] |
Text
TMI T1R21 SG Tube In-service Inspection NRC Call Tim Heindl Steam Generator Program Engineer November 9,, 2015
Agenda Design Overview of TMI-1 Enhanced Once-Through Steam Generator (EOTSG)
T1R21 Steam Generator (SG) Inspection Overview SG Tube Inspection Discussion Points Q&A Acquisition Status:
A OTSG - Acquired 86.0%, Analyzed 82.9%
B OTSG - Acquired q 96.0%,, Analyzed y 95.8%
TMI-1 EOTSG Overview PRIMARY INLET Tube Information Number of Tubes: 15,597 Tube Material: Alloy 690TT Nominal OD: 0.625 inch Nominal Thickness: 0.037 inch Tube Length: 673.375 inch STEAM OUTLET UPPER SHROUD Support Information TSP Material: SA 240 type 410M SS TSP Thickness: 1.18 LOWER MAIN SHROUD TSPs Trefoil broached (15th TSP drilled on periphery) FEEDWATER HEADER Tubes hydraulically expanded full length of the TS Normal Operating Parameters NOP (Primary) = 2,155 psig The image cannot be display ed. Your computer may not hav e enough memory to open the image, or the image may hav e been corrupted. Restart y our computer, and then open the file again. If the red x still appears, y ou may hav e to delete the image and then insert it again.
NOPD = 1271 psid THot = 603oF OUTLET NOZZLES
T1R21 Steam Generator Inspections Inspection Scope:
100% full-length inspection (bobbin probe) 2-Tube Periphery for Loose Parts (combo array probe) TTS to 01S Diagnostic Di ti EExams anddTTube b Pl Plugging i as needed d d Other Actions Taken:
Revised plant heat-up procedures to equalize temperatures to mitigate wear Met with NRC Region I & Site Residents to achieve alignment on inspection scenarios/strategy
- 1. Primary-to-Secondary Leakage No observable primary-to-secondary leakage (PSL) during Cycle 20.
RM-A-5/15 monitor PSLR Continuously.
No observable trends.
- 2. Secondary Side Pressure Tests There were no secondary side pressure tests performed during T1R21.
A drip or bubble test was not required due to the absence of existing primary primary-to-secondary to secondary leakage leakage.
- 3. EPRI Guideline Exceptions TMI-1 has not taken any exceptions or deviations from the EPRI SGMP Guidelines.
- 4. Detailed Scope Evaluation
- 100% full length exam of both OTSGs with bobbin probe
- 2-tube periphery array combo probe exam from TTS to 01S
- All bobbin I codes, PLPs, new DNG /DNT >=
DNGs/DNTs > 1.0V 1 0V examined i d withith array probe
- Deepest 20 TTW indications in both OTSGs examined with array probe and sample of new and repeat indications for flaw characterization.
characterization
- No expansion criteria due to 100%
base scope exam.
- 5. Summary of Inspection Results Tube-to-Tube Wear TSP Wear A B A B Number of New 6 6 2023 2132 Number of Repeat 105 276 2502 3282 Total Indications 111 282 4525 5414 Avg.
g Growth Rate 0.19%/EFPY
/ 0.31%/EFPY
/ 0.54%/EFPY
/ 0.83%/EFPY
/
95th Percentile 1.06%/EFPY 1.06%/EFPY 3.17%/EFPY 4.23%/EFPY Largest New 10% 10% 33% 35%
Largest Repeat 20% 17% 24% 64%
Location of Largest Flaw 70-100 22-63 137-1 2-4
A OTSG TSP Wear Distribution B OTSG TSP Wear Distribution
- 6. Repair/Plugging Plans All tubes repaired will be mechanically roll plugged and stabilized in accordance with stabilization criteria.
All tubes with indications 40% through-wall (TW) will be plugged per Tech Specs.
A total of 25 tubes are currently 40% the Tech Spec Plugging Limit Limit.
The team has developed p a base p plugging gg g strategygy which provides a 99% POS in the W-axis.
- 7. In-situ Pressure Test / Tube Pulls There are currently zero indications that exceed the Condition Monitoring limit (e.g., no in situ pressure testing is required).
required)
- 8. Loose Parts Inspections performed to detect loose parts:
- Two (2) tube periphery with array probe - Approximately 902 tubes/SG Loose parts detected to date:
- NONE Loose parts removal plan/damage:
- N/A - No loose parts to date 9 Secondary Inspections/Maintenance 9.
No secondary inspections or maintenance planned for T1R21 steam generator inspections Perform sludge mapping with ECT
- 10. Unexpected or Unusual Results There are no unexpected or unusual results from the T1R21 eddy current inspections.
T1R20 Operational Assessment Prediction:
- Median deepest projected indication is 69% TW
- Upper 95th value, max projected depth is 77% TW
- Number of New Flaws Predicted: 3,000 in B OTSG Results of the T1R21 inspection are within the previous OA projections and bounded by T1R20 results.
- 11. Schedule A OTSG - Acquired 86.0%, Analyzed 82.9%
B OTSG - Acquired 96.0%, Analyzed 95.8%
Expected to complete eddy current inspections 11/10 @
02:00 Tube Plugging gg g ((as needed)) window is 11/10/15 - 11/13/15