ACRS MEETING WITH THE U S NUCLEAR THE U.S. NUCLEAR REGULATORY COMMISSION June 4, 2009
OVERVIEW MARIO V. BONACA
Accomplishments Since our last meeting with the Commission on November 7, 2008, we issued 16 Reports Topics included:
C t i t
id t
3
- Containment accident pressure credit issue
- Selected Chapters of the ESBWR design certification application
- Vogtle early site permit application and limited work authorization
- Technical basis for revising 10 CFR 50.46(b) loss-of-coolant 4
10 CFR 50.46(b) loss of coolant embrittlement criteria for fuel cladding materials
- Pressurized thermal shock rule
- Regulatory Guide on managing the safety/security interface
- Regulatory Guide on cyber security programs for nuclear facilities 5
- Options to revise NRC regulations based on ICRP recommendations
License Renewal Since November 2008:
Completed review of the Vogtle license renewal application Performed interim review of four applications (Beaver Valley, Indian Point, Three Mile Island 6
Indian Point, Three Mile Island Unit 1, and Susquehanna)
Performed interim review of the NIST research reactor
Discussed with the staff the status of license renewal activities, interim staff guidance, and implementation of the recommendations from the self assessment 7
- Will perform final review of six applications, including NIST research reactor, during CY2009
- Will review updates to the GALL Report and license renewal guidance documents 8
guidance documents
Extended Power Uprates We have expressed concerns with credit for containment accident pressure associated with EPUs in our February 16, 2007, and March 18, 2009, reports 9
reports We will review the Browns Ferry Unit 1 EPU after receiving the complete safety evaluation report
Browns Ferry Units 2 and 3 EPU application review has been deferred by the staff at the request of TVA. ACRS will review this application after receiving the complete safety 10 receiving the complete safety evaluation report.
New Plant Activities Completed review of the SER Chapters for the ESBWR design certification application
- Provided six interim letters on 20 Chapters 11 on 20 Chapters
- Will review the resolution of open items and the ACRS issues and the final SER
Completed review of the early site permit application and limited work authorization for the Vogtle plant Reviewing topical reports associated with the US-APWR 12 associated with the US APWR design Reviewing revisions to the AP1000 Design Control Document
Review of the SER on the EPR design certification application will start in July 2009 Review of the SER on North Anna COL application, referencing 13 ESBWR design will begin in June 2009
Will continue to interact with the NRO staff to establish schedule for review of design certification and COL applications to ensure timely completion of ACRS review 14
Ongoing/Future Activities Advanced reactor research plan Combined license applications 15 pp Design certification applications Digital instrumentation and control systems
Extended power uprates Fire protection High-burnup fuel and cladding issues Human reliability analysis 16 License renewal applications New fuel designs and materials Next generation nuclear plant (NGNP) project Pellet clad interaction failure under EPU conditions
Research quality assessment Revisions to regulatory guides and SRPs Risk-Informing the regulations Safeguards and security matters Safety culture 17 Safety culture Safety research program report Seismic issues
State-of-the-Art Reactor Consequence Analyses (SOARCA) Project Sump strainer issues TRACE code applicability to new reactors 18 new reactors Waste management, radiation protection, decommissioning, and materials issues Watts Bar Unit 2 operating license
Crediting Containment Accident Pressure in the 19 NPSH Calculations William J. Shack
NPSH Margin z Satisfactory performance of the ECCS and containment heat removal system pumps requires adequate NPSH margin z RG 1.1: Emergency core cooling 20 g
y g
and containment heat removal systems should be designed so that adequate NPSH is provided to system pumps assuming no increase in containment pressure from an accident
z To maintain defense in depth, it is desirable that ECCS function not depend on containment integrity, so that an unexpected loss of containment integrity not lead Defense in Depth/Additional Safety Margin 21 containment integrity not lead automatically to core melt z Intent of RG 1.1 is to ensure that this independence of the ECCS function be maintained consistently for all reactors
z Sump strainer blockage is a complex issue. Difficult to provide a demonstrably conservative answer. Desirable to maintain margin to address uncertainties 22
Extended Power Uprates For some plants, demonstrating adequate NPSH for EPU operation would require:
-Credit for all of the predicted 23 containment accident pressure
-Reliance on operator action to maintain NPSH
- Reliance on COP credit for long duration
- In some cases, pump cavitation is expected even after crediting all of the predicted accident 24 p
pressure
- NRC should seek to maintain independence of containment function and accident mitigation and additional margin for NPSH 25
ACRS MARCH 18, 2009 LETTER Intended primarily to address voluntary requests for a change in the licensing basis SRP should be revised to state that, if COP credit is granted 26 that, if COP credit is granted based on risk information, all subsequent licensing applications involving COP credit should also include risk information
Demonstrate that it is not practical to reduce or eliminate the need for COP credit by hardware changes or requalification of equipment 27 If credit for COP is granted, it should be limited in amount and duration
If operator actions are required to maintain overpressure, it must be demonstrated they can be performed reliably, and that any increase in risk is acceptably small 28
Continue to use guidance in RG-1.82 Rev. 3 and the licensing-basis analyses assumptions and methods to show that the Recommendation on Analyses and Revision of RG-1.82 29 available NPSH exceeds that needed for the ECCS and containment heat removal system pumps
If COP credit based on the licensing-basis analyses is not small and limited in duration, RG-1.82 should be revised to request additional analyses and 30 y
information that demonstrate the COP credit needed is small and limited in duration on a more realistic basis
Such information could include thermal-hydraulic analyses that reduce conservatism but account for uncertainties and PRA results that show that large COP credit is needed only for very low probability events 31 very low-probability events If operator actions are required, it should be shown they can be implemented in procedures and performed reliably and that any resulting increases in risk are small
ACRS Position on Decisionmaking
- Granting COP credit should depend on integrated decisionmaking that considers less conservative estimates of 32 the COP credit; the likelihood of scenarios that require COP credit; and the operator actions required to maintain NPSH
Conclusion Our March 18, 2009 letter is consistent with long-standing ACRS position Expect to provide technical input to the development of Revision 4 33 to RG-1.82
- Had a briefing on a draft of the staffs White Paper. While comprehensive, it did not resolve the ACRS concerns
- In the review of any particular 34 y p application for credit, the fidelity of containment and core calculations need to be taken into account
BWROG submitted and staff reviewed a more realistic methodology for evaluating COP credit ACRS awaits the staffs safety evaluation of the BWROG 35 evaluation of the BWROG methodology
Pressurized Thermal Shock Rule J. Sam Armijo
Rule Requirements This rule requires plant-specific evaluations of vessel embrittlement and flaw distributions. It also requires evaluation of new surveillance 37 evaluation of new surveillance data to ensure detection of unexpected embrittlement trends
Three Plant Study The screening limits are based upon a detailed study of the PTS challenges at three plants Medium and large LOCAs were the major contributors to the 38 the major contributors to the through-wall cracking frequency (TWCF), which is the risk metric
Generalization A generalization study evaluated the variability of PTS challenges from internal events in plants not included in the detailed study 39 The likelihood and severity of the important PTS challenges were determined to be representative of those for the entire fleet of PWRs
A bounding analysis on the effects of external events showed that their contribution to TWCF was less than that of internal events Together with the 40 Together with the generalization study on internal events, this finding provides assurance that plant-specific analyses of PTS challenges are not needed
The Committee concurs with the staffs conclusion that plant-specific evaluations of PTS challenges are not needed and that the screening criteria 41 and that the screening criteria in 10 CFR 50.61a may be applied to the entire fleet of PWRs
Recommendations To aid in the implementation of the rule, the staff should undertake an effort to verify and document the capability of NDE procedures that will be 42 NDE procedures that will be used to characterize the flaw distributions in reactor vessels
An effort is needed to plan for the most effective use of surveillance samples to ensure that any deviations from the current understanding of 43 cu e t u de sta d g o embrittlement trends in reactor vessels will be identified in a timely manner
Digital I&C Matters 44 Digital I&C Matters George E. Apostolakis
Reviewed Regulatory Guide 5.71, Cyber Security Programs For Nuclear Facilities Reviewed Digital I&C Interim Staff Guidance 5, Highly-Integrated Control Room-45 Integrated Control Room Human Factors Issues, and 6, Licensing Process
ACRS March 19, 2009 Report
- RG-5.71 on cyber security should not be published until it is revised to:
Provide a reference DI&C 46
-Provide a reference DI&C computer, communication, and network security framework that identifies assets, associated plant functions, vulnerabilities, interaction, and access pathways
- Include examples and more specific guidance on how the requirements of 10 CFR 73.54 can be met
- Ensure that the guidance distinguishes between DI&C 47 distinguishes between DI&C system and non-real-time information technology system architectures
- Address the issues of threat assessment, dependency analysis, and the use of Probabilistic risk assessment 48
ACRS April 21, 2009 Report on Digital I&C Interim Staff Guidance 5 and 6 Section 3, Crediting Manual Operator Actions in Diversity and 49 Defense-in-Depth (D3) Analyses, of ISG-5 should be revised to incorporate additional guidance on the estimation methods of the time required for operator action
Increased rigor in the supporting analyses should be required as the difference between the time available and the time required for operator action decreases 50
Draft ISG-6 should not be issued until Sections C and D are revised to specify that sufficient design detail be provided to ensure deterministic behavior and independence of each DI&C safety train 51
Options to Revise NRC Regulations Based on ICRP Regulations Based on ICRP Recommendations Michael T. Ryan
Staff Options No changes to existing framework Update parts of regulations, not previously revised, to conform to existing 10 CFR Part 20 concepts 53 g
p and quantities based on ICRP Publications 26 and 30 Begin to further align NRCs regulatory framework with ICRP Publication 103
ACRS endorses the staffs preferred option 3, which would begin to move toward greater alignment between 10 CFR Parts 20 and 50 and Appendix I of Part February 18, 2009 ACRS Report 54 20 and 50 and Appendix I of Part 50 with recommendations in ICRP Publication 103
ACRS concurs with the staff position that NRCs current regulatory framework continues to provide adequate protection for the health and safety of 55 workers, the public, and the environment
The staff should continue its participation in ICRP and other national and international committees and standards organizations The NRC should not develop 56 The NRC should not develop separate radiation protection regulations for plant and animal species
Progress on Recommendations of the Independent External Review Panel on the Materials Licensing Program Michael T. Ryan
- The staff has addressed each of the recommendations of the Independent External Review Panel
- The staff has developed Interim Staff Guidance for reviewing new 58 58 Staff Guidance for reviewing new license applications
- Includes more detailed information gathering and on-site applicant visits
- Staff is developing a process to integrate the National Source Tracking and the Web-Based Licensing Systems as part of the License Verification System
- Efforts are under way to i t t
ll 37 A t
59 59 integrate all 37 Agreement States into this system
- This integration will take time and resources to complete and implement
- Staff is pursuing ways to add more detail to the physical security requirements as recommended by the Panel and will be addressed in currently planned rulemakings for larger 60 60 planned rulemakings for larger sealed sources
- Adding Security with equal emphasis as Health, Safety, and Environment for materials licensees will require a change in the culture of the Agency Th A
d th A
t 61 61
- The Agency and the Agreement States share this responsibility
- The staff has plans to accomplish the objectives developed from all of the Panels recommendations
- Some short term goals have already been accomplished 62 62 y
p
- Additional progress will take time and resources
Abbreviations ACRS Advisory Committee on Reactor Safeguards BWR Boiling water reactor BWROG Boiling Water Reactor Owners Group CFR Code of Federal Regulations COL Combined license COP Containment overpressure CY Calendar year D3 Diversity and defense in depth DI&C Digital Instrumentation and Control ECCS Emergency core cooling system EPR Evolutionary Power Reactor EPU Extended power uprate ESBWR Economic Simplified Boiling Water Reactor GALL Generic Aging Lessons Learned Report ICRP International Commission on Radiological Protection ESF Engineered safety features I&C Instrumentation and control 63 ISG Interim staff guidance LOCA Loss-of-coolant accident NDE Non-destructive examination NGNP Next Generation Nuclear Plant NIST National Institute of Standards and Technology NPSH Net positive suction head NRC Nuclear Regulatory Commission NRO Office of New Reactors PRA Probabilistic risk assessment PTS Pressurized thermal shock PWR Pressurized water reactor RG Regulatory Guide SER Safety evaluation report SRP Standard Review Plan SOARCA State-of-the-Art Reactor Consequence Analyses TVA Tennessee Valley Authority TWCF Through-wall cracking frequency US-APWR United States - Advanced Pressurized Water Reactor