E-1 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N appendix E - detention basin inventory This table presents a summary of the detention basin inventory conducted by the Lake County Stormwater Management Commission. The data in this table is mapped in Chapter 3. This table includes the following information: watershed, basin identif cation number, whether the basin was built before or after the adoption of the Watershed Development Ordinance, active storage volume (if available), and the problems or issues identif ed during the basin inventory.
Watershed Basin Number Pre WDO?
Active storage volume (cu ft) / Not Detention Basin (NCB) / Not Assessed (NA)
Create wet or wetland basin Plant side slopes with native vegetation Improve and expand buffer Inlet / outlet clean out or replacement Stabilize / regrade shoreline Address algae /
nutrients Address turbidity /
sedimentation Remove concrete channels Debris, garbage, and/
or woody vegetation removal DR 1
525,490 ft cu X
X X
X X
X DR 2
23,000 ft cu X
X X
X X
DR 3
X NDB / 65,050ft cu DR 4
X NA DR 5
X 12,168 ft cu X
X X
DR 6
X 19,724 ft cu X
X X
X X
DR 7
X 24,924 ft cu X
X X
X X
DR 8
X 140,310 ft cu X
X DR 37 X
103,136 ft cu X
X X
X DR 38 X
31,724 ft cu X
X X
DR 39 X
40,285 ft cu X
X DR 41 X
121,713 ft cu X
X X
X DR 42 X
189,361 ft cu X
X X
X DR 44 X
16,704 ft cu X
DR 45 X
45,028 ft cu X
X DR 46 X
10,668 ft cu X
X DR 47 X
151,908 ft cu X
DR 50 X
4,036 ft cu X
X DR 53 X
28,708 ft cu X
X DR 54 X
20,948 ft cu X
X X
X DR 55 X
NA DR 56 X
60,096 ft cu X
X DR 57 X
230,984 ft cu DR 58 X
237,952 ft cu X
DR 59 X
282,819 ft cu X
DR 60 X
248,767 ft cu X
DR 61 X
73,134 ft cu X
X X
X
E-2 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N appendix E - detention basin inventory results
- Storage for detention basins numbered in the 200s were estimated based on basin dimensions and an assumed two-foot depth.
DR 62 X
20,185 ft cu X
X X
DR 63 X
400,052 ft cu X
DR 64 X
85,264 ft cu X
X X
X DR 65 X
167,319 ft cu X
X X
DR 66 X
314,268 X
X DR 67 X
23,526 X
X X
X X
DR 68 X
22,112 X
X DR 70 X
NA DR 71 300,320 X
X DR 72 110,360 X
X X
DR 73 X
X DR 74 319,150 X
X X
X DR 75 NA DR 76 NA DR 112 106,049 DR 113 NA DR 114 NA DR 203 X
NA / 184,593 DR 205 X
NDB / 14,807 DR 206 X
NA / 48,578 DR 207 X
NA / 267,929 DR 208 36,518 X
X X
DR 209 50,187 X
X X
X DR 210 89,330 DR 211 X
NDB / 15,734 DR 212 X
14,388 X
X X
DR 213 X
NDB / 15,105 DR 214 X
NDB / 11,249 DR 215 NA / 112,280 DR 216 NA / 128,705 DR 221 X
NA / 97,710 DR 228 X
22,151 X
X X
Watershed Basin Number Pre WDO?
Active storage volume (cu ft) / Not Detention Basin (NCB) / Not Assessed (NA)
Create wet or wetland basin Plant side slopes with native vegetation Improve and expand buffer Inlet / outlet clean out or replacement Stabilize / regrade shoreline Address algae /
nutrients Address turbidity /
sedimentation Remove concrete channels Debris, garbage, and/
or woody vegetation removal
E-3 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N DR 229 X
NDB / 17,169 DR 230 X
NA / 52,429 DR 231 X
NDB / 73,073 DR 232 X
5745 X
X X
DR 233 X
NA / 33,060 DR 234 X
NA / 214,901 DR 235 X
NDB / 90,542 DR 236 X
NDB / 52,365 DR 237 X
NDB / 105,232 DR 238 NDB / 13,600 DR 239 X
NA / 82,689 DR 240 X
NA / 12,495 Watershed Basin Number Pre WDO?
Active storage volume (cu ft) / Not Detention Basin (NCB) / Not Assessed (NA)
Create wet or wetland basin Plant side slopes with native vegetation Improve and expand buffer Inlet / outlet clean out or replacement Stabilize / regrade shoreline Address algae /
nutrients Address turbidity /
sedimentation Remove concrete channels Debris, garbage, and/
or woody vegetation removal
- Storage for detention basins numbered in the 200s were estimated based on basin dimensions and an assumed two-foot depth.