ML15188A125

From kanterella
Jump to navigation Jump to search
Dead River Watershed - Based Plan 2008, Part 7 of 25
ML15188A125
Person / Time
Site: Zion  File:ZionSolutions icon.png
(DPR-039, DPR-048)
Issue date: 09/30/2008
From:
Lake County Stormwater Management Commission
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML15188A105 List:
References
ZS-2015-0084
Download: ML15188A125 (17)


Text

225 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N FIGURE 5.6 SUBWATERSHED MANAGEMENT UNIT 3C Legend This map is provided for general locational information only. Map features have been derived from various sources, each of which has its own scale and accuracy. The locations of all features are approximate.

Lake County Stormwater Management Commission September, 2007 DATA SOURCES:

Lake County Stormwater Management Lake County Department of Information And Technology, GIS & Mapping Division Forest Preserve State Park Watershed Boundary SMU Boundary Point Discharges Hydraulic Structures Priority Green Infrastructure Areas Subbasin Boundary Stream Reach Critical Stream Reach Critical Subbasins ADID Wetlands Regional Storage Critical Region Wetlands Detention Basins Instream Problem Areas Action Recommendations Subwatershed Management Unit 1.0.1 152 52 10 2

KC1 KC1 FPAI Site 20-07 Wadsworth Rd.

R Sheridan Rd.

rid n S

d R

e idid Sh S

N o

N r

t h

t Bra n

c h

B u

B l

u l

l C

r C

e r

ek e

wk Golf wk Golf Thunderhaw nderhaw Club Forest Pre Club serve ve Lewis Ave.

e R

S dann R Sheridan R rid n S

d e

Sh idd S

BL28 BL27 BL26 BL20 BL08 BL21 BL19 BL09 BL10 BL07 BL24 BL23 BL22 BL17 BL18 BL15 BL14 BL11 BL04 BL06 20-06 0-05 20-02 20-04 20-07 4

2 48 22 69 61 57 64 64 43 73 2

3c 3b 3B.13.1-7 3B.14.1-2 3B.0.2-3 3B.0.7 70 70 34 34 46 46 41 41 47 47 43 43 32 32 48 48 49 49 30 30 27 27 55 55 56 56 57 57 58 58 45 45 40 40 78 78 39 39 28 28 29 29 3A.27.8 3A.27.4 3A.27.7 3A.27.5 3A.0.1 3A.25.1-3 3A.26.1-4 3A.27.1-2 3A.27.3 3A.25.5 3A.26.6 3A.27.9 3A.26.5 3C.20.7 3C.24.2 3C.24.1 3C.21.6 3C.21.5 3C.21.4 3C.21.4 3C.20.11 3C.20.9 3.18.3 3B.17.7-8 3B.17.6 3B.17.5 3B.17.9 3B.0.4 3B.16.8 3B.16.7 3B.13.8 3B.15.6-7 3B.15.11 3B.15.10 3B.14.3 3B.13.12 2.28.9 2.28.12 2.28.10 2.28.8 2.28.7 2.28.12 2.28.6 2.28.1,2,5 3C.8.9 3C.7.9 3C.8.7 3C.8.8 3C.8.11 3C.8.7 3C.8.12 3C.8.13 3C.0.4 3A.27.6 3A.27.11 3A.27.10 3C.10.3 3C.10.4 3C.9.12 3C.11.4 3C.11.5 3B.15.9 3C.9.10 3C.9.11 3C.9.6 2.0.4 2.0.1 2.0.1 2.0.1 2.28.3-4 1.0 1.0.26 1.0.2 1.0.23 1.0.24 1.0.27 1.0.8 1.0.3 1.0.22 1.0.21 2.0.6 2.0.7 3C.0.15 3C.0.16 3B.0.20 3B.0.21 3B.0.9 3B.0.10 3B.0.19 3B.0.5 4.0.9 3B.0.12 3B.0.13 3B.0.8 3B.0.15 3B.17.1-4 3B.16.5-6 3B.18.1-2 3C.0.14 3C.0.5 3C.0.3 3C.0.1 3C.21.4 3C.11.1-3 3C.10.1-2 3C.9.1-4 3C.8.6 3C.20.1 3C.21.7-8 3C.20.1-4 3C.0.17 3C.0.2 3C.0.13 3C.0.12 3C.0.11 3A.0.6 3A.0.10 3A.0.5 3A.0.4 3A.0.3 3A.0.2 3C.0.10 3C.23.1 3A.0.16 3A.0.15 3A.27.1 3C.0.8 3C.0.9 3C.0.4 3C.21.1-2 3C.7.1-4 3C.7.5 3C.0.7 3C.0.9 1.0.15 1.6.1-2 1.0.9 1.0.14 5.0.4-5 5.0.3 5.0.2 5 4 3 5.4.1-2 Glen Forest Trib Lyons Woods ve Forest Preserv rerest Preserv BL04 20-0-06 06 43 43 4

3 73 73 73 733 73 5.0.4-5 5.0.3 5.0.3 5.0.2 5

.2 5 4 3 5.4.1-2 9

29 29 29 29 0.9 4.00 Beach Rd.

a d

Beach Rd a

d North Ave.

h A outh t

B Bu lll Cr C

e r

k Wi W li sl o n A ve n

u e

Tr T ibi.

Be B

uth t

B ou BL17 BL1 BL18 B

BL15 B

5 B

BL14 0-055 05 20-044 04 69 61 577 57 57 5

3b Bu 3B.13.1-7 1

3 1-3B.14.1-2 B

3B.14.1 1

3B.0.2-2-33

-3 7

3B.0.77 0

4 34 34 344 34 3

46 46 46 46 46 3

43 43 43 43 43 4

32 32 32 3

48 48 48 48 48 4

3.18.3 3B.17.7-88 17 3B.

3B.17.6 3

1 3B. 7.5 1

3B 3B.17.9 3B.

3B 17 9 B.0

.0.4 3BB 4

3B.16.8 6

3B.16.7 3B.16.7 3B.13.8 1

3B.15.6-7 3

1 11 15..

3B.11 B

Cr Cr 5.10 5

0 10 3B.11 B 15 3B.14.3 3B 14 3 B 14 3 3

3B.13.12 3

3B.15.9 1

3 0.20 3B.0.20 0.20 3B.0.21 0

3 3B.0.9 B.0.10 B.0.10 3B 3B 0 1 3B.0.19 3B.0.5 3B.0 3B.0.12 0 1 3B.0.133 1

B

.88 B.

3B.

B..0.

0 3

3B 3B.0.15 3B.17.1-4 B.16.5-6

-6

-6

.16.5

.16.5 3

6.5 3

2 3B.18.1-2 1-2 33rd St.t e

e e

t T

r T

i b

i u

tat r

y r

BL27 B

BL26 B

20-0-077 07 4

48 488 48 48 48 8

78 78 78 78 78 788 78 78 78 7

3A.27.8 2

3A.27.4 3A.27.7 A

3A.27.55 A

3A.0.11 3A.25.1-3 5

3A.26.1-4 6

3A.27.1-2 7

3A.27.3 3A 27 3 3A.25.5 3A.

A.25.5 A.

3A 3A 3A 3A.26.6

.6 3A.26..

3A.27.9 2

3A.26.5 A

3A.27.6 7 6 2

A 2 A

3A 2 A

3A.27.11 7

A 3A 27 10 7

A 3A.27.10 3A.0.6 3A.0.10 A 0 10 A

3A.0.5 3A.0.4 3A.0.4 3A.0.3 0

3A.0.2 3A.0.16 3A.0.15 3A.27.1 3A.2.1 29th St.

S 2

h BL28 2

2 2

5 55 55 55 5

6 56 56 56 5

57 57 57 5

2.28.9 2 288 9 2.28.12 1

2 2.28.10 8

2.28.8 8

2.28.7 2 28 7 2.288.12 8 1 2.28.6 2

2.28.1,2,5 2.

2.0.4 0

2.0.1 2.

1

.1 0

2.

1 0

2.0.1 1

0.

0 2.0.

0 2.0.1 2.28.3-4 2.228.3 4 2

6 2.0..6

.6 2.0.7 2.0.

ILLIN LI STA STA Dead River BL BL06 BL06 27 27 58 58 58 58 58 40 40 40 39 39 39 39 8

28 28 28 28 28 28 28 28 28 1.0 1.0.26 1.0.2

.0 1.0.23 3 1.0.24 1.0 7

0.27 0

7 1.0.8 1.0.3 1.0.22 1.0.21 1.0.15 1 0 15 1.6.1-

-2 1.0.99 0

1.

9 1.0.14 Yorkhouse Rd.

s k

d B 6 B

4 9.10 9.10 3C.20.10 3C.20.8 3C.20.6 3C.20.5 3C.19.6 3C.19.5 3C.8.6 3C.8.10 3C.8.4-5 3C.8.1-3 3C.0.9 3C.8.14 3C.0.4 3C.9.5 3C.9.7 3C.9.9 3C.9.8 3C.11.7 3C.19.7 3C.22.2 3C.22.1 3C.0.6 3C.11.8-9 3C.11.10

226 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N Legend This map is provided for general locational information only. Map features have been derived from various sources, each of which has its own scale and accuracy. The locations of all features are approximate.

Lake County Stormwater Management Commission September, 2007 DATA SOURCES:

Lake County Stormwater Management Lake County Department of Information And Technology, GIS & Mapping Division Forest Preserve State Park Watershed Boundary SMU Boundary Point Discharges Hydraulic Structures Priority Green Infrastructure Areas Subbasin Boundary Stream Reach Critical Stream Reach Critical Subbasins ADID Wetlands Regional Storage Critical Region Wetlands Detention Basins Instream Problem Areas Action Recommendations Subwatershed Management Unit 1.0.1 152 52 10 2

KC1 KC1 FPAI Site 20-07 anchard Rd.

Rd rd R rd Rd.

d.

ha n

R.

21 21 BL03 BL05 BL06 BL02 BL01 0-05 5

40 5

4 28 28 17 17 8

29 29 5.2.5 5.2.8 5.2.10 5.2.4 5.2.7 5.2.6 1.1.6 1.1.1-3 1.1.5 5.2.12 5.3.1-2 4.0.4 4.0.6 1.0.23 1.0.8 1.0.22 1.0.21 3B.0.21 3B.0.9 3B.0.19 3B.0.5 4.0.9 4.0.8 5.0.7 5.0.8 5.0.6 1.0.4 1.1.4 1.0.15 1.0.10 1.6.1-2 1.0.13 5.4.1-2 od Ave.

Greenwo wood Ave.

wood Ave.

r nwoo Bll Glen Forest Trib Lyons Woods ve Forest Preserv e

es Forest P Forest Preserv 21 21 2

BL03 L

BL02 5555 5

8 5.2.5 5.2 5.2.8 5.2.10 5 2 10 5.2.4 5

5.2.7 2.6 2

5.2 6 5 2 5.2.6 5.

5.2.12 5.

2 5.3.1-2 5.0.7 0.8 5.00 5.0.6 5.4.1-2 North Ave.

h A 0-055 05 3B.0.21 0

3 3B.0.9 0 1 3B.0.19 3B.0.5 3B.0 S BEACH BEA ILLINOIS LI TE PARK E PA STATE STA BL BL06 BL06 BL01 8

28 28 28 28 28 28 28 28 28 1.1.6 1.1.1-3 1.1.5

.5 1.0.23 1.0.8 1.0.22 1.0.21 1.0.4 1.1.4 1.0.15 1 0 15 1.0.10 1.6.1-

-2 1.0.13 alaa 4.0.1 4.5.5 4.5.3 4.0.2 4.5.1-2 4.5.4 4.0.7 FIGURE 5.7 SUBWATERSHED MANAGEMENT UNIT 4

227 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N Legend This map is provided for general locational information only. Map features have been derived from various sources, each of which has its own scale and accuracy. The locations of all features are approximate.

Lake County Stormwater Management Commission September, 2007 DATA SOURCES:

Lake County Stormwater Management Lake County Department of Information And Technology, GIS & Mapping Division Forest Preserve State Park Watershed Boundary SMU Boundary Point Discharges Hydraulic Structures Priority Green Infrastructure Areas Subbasin Boundary Stream Reach Critical Stream Reach Critical Subbasins ADID Wetlands Regional Storage Critical Region Wetlands Detention Basins Instream Problem Areas Action Recommendations Subwatershed Management Unit 1.0.1 152 52 10 2

KC1 KC1 FPAI Site 20-07 od Ave.

Greenwo wood Ave.

wood Ave.

r nwoo Bl Glen Forest Trib Lyons Woods ve Forest Preserv e

es Forest P Forest Preserv 21 21 BL04 BL03 BL05 BL06 BL02 BL01 20-06 21-04 0-05 43 43 73 73 35 35 39 39 40 14 14 13 13 5

4 3B.14.1-2 30 30 27 27 28 28 23 23 18 18 17 17 6

3 10 10 8

87 87 22 22 29 29 5.2.5 5.2.8 5.2.10 5.2.4 5.0.1 5.2.7 5.2.6 5.2.9 1.1.6 1.1.1-1.1.5 5.2.12 5.3.1-2 4.0.4 4.0.6 1.0.8 1.0.3 1

1 3B.0.21 3B.0.9 3B.0.19 3B.0.5 4.0.9 4.0.8 5.0.7 5.0.8 5.0.6 5.0.11 5.0.10 5.0.9 1.0.15 1.6.1-2 5.0.4-5 5.0.3 5.0.2 5.4.3 5.4.1-2 anchard Rd.

an Rd rd R rd Rd.

d.

ha n

R.

BL005 0

BLL0 0

400 400 400 4

17 17 17 17 299 29 29 29 4.0.4 4.0.6 0.9 4.00 4.0.8 0

0 30 30 30 North Ave.

h A 0-055 05 b.

3B.14.1-2 B

3B.14.1 1

3B.0.21 0

3 3B.0.9 0 1 3B.0.19 3B.0.5 3B.0 E

WAUKE AU AUKEGANN EG RLAND A

MOOR OR BL BL06 BL06 BL01 27 27 8

28 28 28 28 28 28 28 28 28 6

1.1.6 1.1.1-1.1.5

.5 1.0.8 1.0.3 1

1 1.0.15 1 0 15 1.6.1-

-2 Sunset Ave.

n McAree Rd.

d A

Glen Flora Ave.

v a

Fl 21-1-04 04 alaa 5.2.11 5.2.1-2 FIGURE 5.8 SUBWATERSHED MANAGEMENT UNIT 5

228 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N Amstuz Expressway A

xpressway pre pre pre pre res resswa re y

way ressway BL02 BL01 40 14 13 76 11 11 10 10 75 75 5

6 6

3 8

87 87 5.2.8 5.2.10 5.2.4 5.0.1 5.2.7 5.2.6 1.1.6 1.1.1-3 1.1.5 5.2.12 5.0.11 1.0.4 1.1.4 1.0.10 1.0.13 6.0.1 6.0.2 6.0.4-5 od Ave.

Greenwo wood Ave.

wood Ave.

r nwoo BL02 4

14 14 1

13 13 5

3 8

87 87 87 5.2.8 5.2.10 5 2 10 5.2.4 5

5.0.1 0.1 5.2.7 2.6 2

5.2 6 5 2 5.2.6 5.

5.2.12 5.

2 1

1 5.0.1 5.0.1 5 0 11 5 0 1 0

1 5 0 1 0

5.0.11 0

400 400 400 E

WAUKE AU AUKEGAN N

EG RLANDS A

MOOR OR BL01 76 6

1.1.6 1.1.1-3 1.1.5

.5 1.0.4 1.1.4 1.0.10 1.0.13 a Ave.

v a

Legend This map is provided for general locational information only. Map features have been derived from various sources, each of which has its own scale and accuracy. The locations of all features are approximate.

Lake County Stormwater Management Commission September, 2007 DATA SOURCES:

Lake County Stormwater Management Lake County Department of Information And Technology, GIS & Mapping Division Forest Preserve State Park Watershed Boundary SMU Boundary Point Discharges Hydraulic Structures Priority Green Infrastructure Areas Subbasin Boundary Stream Reach Critical Stream Reach Critical Subbasins ADID Wetlands Regional Storage Critical Region Wetlands Detention Basins Instream Problem Areas Action Recommendations Subwatershed Management Unit 1.0.1 152 52 10 2

KC1 KC1 FPAI Site 20-07 FIGURE 5.9 SUBWATERSHED MANAGEMENT UNIT 6

229 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N 5.4 INFORMATION AND EDUCATION PLAN A watershed-based plan must include a strategy to inform and educate the public and stakeholders about watershed issues and to encourage them to take positive action, to support watershed plan implementation, to improve private land management, to become involved in watershed stewardship activities, and to change behavior that may be impacting watershed resources. Because many watershed problems result from individual actions and the solutions are often voluntary practices, ef fective public involvement and participation promote the adoption of management practices, help activate the implementation of the watershed-based plan, and encourage changes in behavior that will help improve watershed resources. Furthermore, the general public is often unaware of the environmental impact of day-to-day activities on environmental resources. An understanding of watershed issues and how individual activities can play a role in protecting water quality and other resources helps provide the motivation and basis for changing behavior.

There are a limited number of known education programs occurring within or near the watershed area, though there does appear to be a number of individuals and organizations actively involved in environmental issues, such as the Illinois Dunesland Preservation Society

, the W aukegan Harbor Citizens Advisory Group, and volunteers involved with restoration and management in Illinois Beach State Park. These groups, whether through a dedicated education initiative or general public outreach and participation in the community, are engaged in an education and information campaign. A few programs, as reported by watershed stakeholders, include the following:

The W aukegan Harbor Citizens Advisory Group is involved with educating local residents about issues related to the Waukegan Harbor Area of Concern. The group conducts meetings and tours in support of this goal.

A new summer environmental day camp for area 5th grade students is currently in development for Bowen Park in Waukegan. This program will focus on life, earth, and watershed science and will use the nearby ravine as a living laboratory to connect children with nature.

Within Bowman Park, the Chicago Botanic Garden and the United States Forest Service are initiating a program to train volunteers to help monitor amphibians within the park boundary.

At Zion Benton Township High School, Larry Anglada teaches an environmental curriculum to students that includes water resources and aquatic biology.

Area churches are taking on an environmental education role with technical support from Chicago Wilderness.

It is clear from the limited programs focused on environmental education that additional ef forts are needed. This section of the Action Plan includes an identi f cation of the target audiences and partner organizations, a brief description of evaluating the information and education plan, and speci f c action recommendations for conducting the information and educationi campaign, which are presented in Table XX.

A general overall strategy for information, education, and public involvement to address watershed topics and issues is included in Appendix I, along with a list of resources for conducting the education campaign.

Watershed organizations that may be tasked with coordinating and guiding actions within the Dead River watershed should consider developing a separate education committee to help build and implement a more detailed information and education campaign.

5.4.1 TARGET AUDIENCES To d ef ne the audience for educational outreach, contacts should be made with individuals, organizations, and decision-makers within the watershed community to determine their level of understanding of watershed issues and needs for further education and outreach. The intent is to include both existing partners, as well as stakeholders that previously have not been participants, and to be responsive to their needs for information as well as their motivations.

The primary target audiences for this plan are (1) residents and other landowners, (2) land and resource managers and organizations, (3) government off cials and agencies, and (4) developers and contractors. More specif cally, potential target audiences include the following, abbreviations are USEPA watershed-based plan element #5:

public information and education plan.

230 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N 5 prioritized action plan keyed to the education tables:

1.

Residents, other landowners, and visitors Riparian residents and landowners (RR)

Non-riparian residents and landowners (NR)

Homeowner associations (HOA)

General public and visitors (GP)

Businesses and institutions (BI)

2.

Land and resource managers and organizations Land and resource managers, including farmers, golf course superintendents, facility managers, and site stewards (LM)

Organizations, committees, land trusts, professional associations, agencies, and special interest groups interested in the future and management of watershed resources (OG)

3. Government off cials and agencies Local governments, including municipalities, townships, counties, state, health departments, park districts, forest preserve districts, port authorities, and transportation departments that manage land within the watershed (LG)
  • Schools (S)
4.

Developers and contractors Developers and homebuilders (DH)

Consultants and contractors (architects, engineers, planners, landscapers, lawn care) working in the watershed (CC)

The various target audiences will need to hear dif ferent messages or the same message in different ways (and with different emphasis) through a variety of delivery mechanisms, as determined by this plan and through the initial contact with target audiences mentioned above.

A number of strategies for crafting and delivering messages for watershed information and education are provided below. Single issue messages tend to be simple and effective, though messages can also be crafted to address multiple issues such as the link between hydrology and stream health.

5.4.2 PARTNER ORGANIZATIONS Organizations that will be responsible for implementing the watershed plan recommendations can also help implement the information and education strategy as well as be target audiences. Each partner should couple plan implementation efforts with parallel efforts to inform and educate.

Beach Park Drainage District (BPDD)

Chicago Metropolitan Agency for Planning (CMAP)

Corporate and Business Landowners (CBL)

Developers & Homebuilders (DH)

Federal / Illinois Emergency Management Agency (FEMA/

IEMA)

Golf Courses (GC)

Illinois Department of Natural Resources (IDNR) (includes Winthrop Harbor)

IDNR Coastal Management Program (CMP)

Illinois / Lake County Departments of Transportation (DOT)

Illinois Environmental Protection Agency (IEPA)

Lake County Forest Preserve District (LCFPD)

Lake County Health Department (LCHD)

Lake County Planning, Building, and Development (PBD)

Lake County Stormwater Management Commission (SMC)

Lake Michigan Watershed Ecosystem Partnership (LMWEP)

Municipalities (all departments) (M)

National Audubon Society (NAS)

Natural Resources Conservation Service (NRCS)

Soil and Water Conservation Districts (SWCD)

Parks and Recreation Districts and Departments (PD)

Private Residential Landowners and Homeowners Associations (HOA)

North Shore Sanitary District (NSSD)

Townships (T)

Taskforce on Waukegan Neighborhoods (TOWN)

U.S. Army Corps of Engineers (USACE)

U.S. Department of Agriculture (USDA)

U.S. Environmental Protection Agency (USEPA)

U.S. Fish and Wildlife Service (USFWS)

Waukegan Harbor Citizens Advisory Group (WHCAG)

231 T H E D E A D R IV E R l WAT E R S H E D - B A S E D P LA N 5.4.3 EVALUATING THE OUTREACH PLAN Evaluation provides a feedback mechanism for ongoing improvement of your outreach ef fort and for assessing whether the ef fort is successful. It also builds support for further funding. The following ideas should be customized to particular needs of the party responsible for implementing the information and education campaign. For a number of these evaluation strategies, baseline information should be collected before the outreach activities begin and checked periodically throughout the outreach campaign to help measure progress and effectiveness.

Actual reduction in impairment of water quality in the Dead River is perhaps the best indicator of outreach effectiveness.

While it is dif f cult to attribute water quality improvement to specif c outreach strategy programs or actions, there is little doubt that increased understanding and involvement in the watershed is essential to watershed improvement. Speci f c information on monitoring and evaluating an education strategy are identif ed below.

5.4.4 INFORMATION AND EDUCATION STRATEGY FOR DEAD RIVER WATERSHED The Information and Education Strategy tables on the next pages outline a general approach for providing education and outreach to watershed stakeholders.

The table is organized by major Issues and Goals (dark green rows), and by topic area within each of the Issue and Goal categories.

Different strategies may be appropriate for dif ferent scales, e.g., a watershed wide storm drain stenciling campaign or a targeted one-on-one outreach campaign for streamside landowners and residents. The table includes the following information and a key to the table is included at the end.

Issue and Goal: the table is organized around major watershed issues and goals.

Topic: a number of educational topics are recommended for each issue and goal.

Target Audiences: indicates the primary audiences who need to hear the message or receive the information delivered. See the table footnote for explanations and acronyms.

Messages: suggests a number of messages to be disseminated to address the topic, issue, and goal.

Delivery Mechanism / Format: suggests the means by which the message should be distributed.

Anticipated Behavioral Changes / Outcomes: indicates the desired outcome that will result when a message is properly distributed to the target audience.

Evaluation Indicators: suggests means by which progress in implementing the Information and Education Strategy can be measured.

Lead + Partners: recommends the primary parties that should be responsible for crafting and delivering the messages. See the table footnote for explanations and acronyms.

Schedule: indicates the time frame for implementing the recommendation. See the table footnote for explanations and acronyms.

Priority: indicates the relative importance of getting that particular message delivered. See the table footnote for explanations and acronyms.

Status: this column is intentionally blank so that progress can be monitored within the table.

232 ISSUE:

Limited public understanding about watershed resources and the impact of human activities.

GOAL:

Educate the public about general watershed issues.

Topic Target Audiences Messages Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status General watershed awareness GP A

  • You live in a watershed, the area of land where all water drains to a single body of water, in this case, Lake Michigan.
  • Rain falling on your property picks up pollutants found there and carries them to the stream and Lake Michigan. You can manage your property to reduce these pollutants and improve water resources.
  • Help us keep your/our stream clean! YOUR actions impact the stream.
  • Everyone can contribute to solutions, no matter how small the action.
  • Messages in community newsletters.
  • Simple public interest radio and newspaper advertisements.
  • Additional signage at stream crossings.
  • Post paper watershed maps in community buildings, government buildings, schools, and libraries.
  • Landowners, residents, and the general public participate in watershed activities and events.
  • The general public requests additional information, maps, materials, etc.
  • Number of participants in watershed events and activities.
  • Number of requests for additional information, maps, materials, etc SMC M

NRCS LCSWCD LCFPD LCHD AGL CMP TOWN LMWEP PD Short to Long term Medium Table 5.16 Information and Education Plan

233 ISSUE:

Stream restoration and management are needed to improve water quality and restore habitat.

GOAL:

Restore and manage the stream system to protect and enhance stream and riparian health, function, and conveyance as part of a watershed green infrastructure system.

Topic Target Audiences Messages - organize these messages by target audience Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status Stream restoration RR HOA BI

  • Improving the natural habitat features of the stream channel, stabilizing streambanks, and restoring the riparian buffer can bring f sh and other native species back.
  • Eroding streambanks contribute silt and sediment to the stream, impairing water quality, degrading aquatic habitat, and threaten property and infrastructure.
  • Distribute stream management and restoration guidebooks and other print materials.
  • Hold riparian landowner training workshops.
  • Provide stream restoration stewardship and volunteer opportunities.
  • Simple public interest messages on radio.
  • Riparian landowners replace hardscape armoring with bioengineering practices
  • Riparian landowners actively restore stream habitat features.
  • Number of riparian landowners reached / attending workshops.
  • Number of stream restoration and stabilization projects.
  • Participation in volunteer stream restoration events.
  • Requests for assistance or funding for restoration projects.
  • Number of reaches in the High or Moderate streambank erosion category.

SMC M

BPDD NRCS LCSWCD LCFPD LCHD GC IDNR IEPA LMWEP Short to Long term High LM LG CC

  • Bioengineering practices, which use deep-rooted plants and other "soft" solutions to stabilize eroding streambanks, are more effective than rip rap, concrete, and other "hardscape" solutions, and are less detrimental to the stream channel and habitat.
  • Hardscape solutions are strongest when installed and get weaker over time, while bioengineering practices are weakest when installed and get stronger over time.
  • Distribute technical stream restoration and stabilization manuals.
  • Hold technical restoration training workshops.
  • Install stream restoration

/ stabilization demonstration projects.

  • Provide list of funding and technical assistance sources.
  • Land managers and local governments stabilize streambanks with bioengineering practices
  • Number of streambank stabilization projects.
  • Number of reaches in the High or Moderate streambank erosion category.

SMC M

BPDD NRCS LCSWCD LCFPD LCHD GC IDNR IEPA LMWEP Short to Long term High Stream management RR HOA BI LM CC

  • You can improve water quality, stabilize streambanks, reduce erosion, and provide wildlife habitat by maintaining a minimum 30' native riparian buffer along the stream.
  • Invasive and exotic plants can crowd out native plant communities and should be removed and replaced with deep-rooted, native riparian plant species.
  • Save time and money: dont mow to the edge of the creek.
  • Beautify your property: plant native plants and wildf owers along the stream.
  • Landowners are responsible for maintaining the stream on his/her property. You can improve water quality, reduce erosion, and improve the appearance of the stream by keeping garbage, debris, and yard waste away from the stream and its banks.
  • Rooftop and footing drains that discharge water from your property to the stream cause streambank erosion.

Instead, direct this water into rain gardens or rain barrels.

  • Removing creek obstructions and log jams can help reduce erosion and prevent local f ooding problems.
  • Distribute stream management guidelines and other print materials.
  • Hold riparian landowner training workshops on riparian zone management.
  • Publish articles in community newsletters.
  • Provide stream management volunteer opportunities.
  • Install informational signage at stream crossings.
  • Simple public interest messages on radio.
  • Website.
  • Riparian landowners actively manage stream and riparian zone and establish native buffers.
  • Riparian landowners stop dumping branches and other yard waste in and along the stream.
  • Landowners reduce activities that worsen streambank erosion such as rooftop drains, mowing to the edge of the stream, and dumping yard waste.
  • Number of riparian landowners reached through workshops.
  • Number of stream management volunteers.
  • Linear feet of riparian buffer actively managed.
  • Requests for assistance or funding for restoration projects.

SMC M

BPDD NRCS LCSWCD LCFPD LCHD GC IDNR IEPA LMWEP Short to Long term High Table 5.16 Information and Education Plan (continued)

234 ISSUE:

Stormwater runoff contributes to impaired water quality, eroding streambanks, and f ooding.

GOAL:

Improve stormwater management to enhance water quality and reduce erosion and f ood damage.

Topic Target Audiences Messages - organize these messages by target audience Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status Stormwater management RR NR HOA BI LM

  • You can help reduce ravine and streambank erosion and improve water quality by reducing the amount of stormwater leaving your property and entering the stream or storm sewer.
  • You can install stormwater BMPs to f lter and inf ltrate stormwater runoff.
  • Minimize the impact of installed drains (e.g., f exible corrugated plastic pipes), on your property by directing them into a rain garden or other on-site inf ltration BMP.
  • Distribute stormwater management how-to materials such as rain garden guides.
  • Hold property owner training presentations and workshops on stormwater management.
  • Landowners voluntarily act to reduce the rate and volume of stormwater being discharged to ravines and/or stream channels.
  • Landowners stabilize erosion around infrastructure on their property, and report infrastructure problems to the proper authorities.
  • Number of landowners and land managers reached.
  • Number of drain retrof t projects.
  • Number of on-site inf ltration projects for roof and site runoff.

SMC M

BPDD HOA LCPBD IEPA LMWEP TOWN Short to Long term High LG LM BI HOA

  • You can maintain the conveyance capacity of the stream, reduce erosion, and improve water and habitat quality by repairing and maintaining failing, impaired, or obstructed stormwater outfalls, culverts, and channels.
  • You can retrof t detention basins and drainage swales to help improve water quality and inf ltrate water into the ground.
  • Meet with landowners, municipalities, and others who manage these stormwater features.
  • Hold training presentations and workshops on stormwater infrastructure management.
  • Stormwater infrastructure managers and municipalities monitor, maintain, and repair the conveyance system and structures on a regular basis.
  • Stormwater infrastructure managers and municipalities actively manage and retrof t detention basins and swales with deep rooted vegetation and other measures to help improve water quality.
  • Number of swale and detention basin retrof t projects.
  • Number of new detention basins and swales using BMPs.

SMC M

BPDD HOA LCPBD IEPA LMWEP TOWN Short to Long term High Table 5.16 Information and Education Plan (continued)

235 ISSUE:

The watershed experiences f ood risk and f ood damage.

GOAL:

Reduce f ood damage and prevent increased f ooding to protect public and private property and investments.

Topic Target Audiences Messages Delivery Mechanism Anticipated Behavioral Changes / Outcome Evaluation Measure Partners Schedule Priority Status Floodproof ng and f ood risk awareness RR NR HOA BI

  • Landowners in and near the f oodplain should be aware of f ood risk and the importance of f ood insurance.
  • Landowners can protect their property and mitigate f ood losses and/or f ood damage through buyouts and f ood proof ng techniques.
  • Landowners can call on a variety of local and county agencies for f ood response assistance.
  • Excess water has to go somewhere: your basement or the f oodplain?
  • Flooding is expensive.
  • Distribute print information to landowners with property in or near f oodplain or f ood problem areas.
  • Hold workshops for landowners on f oodproof ng and f ood awareness.
  • Website
  • Floodplain insurance held by all who need it.
  • At risk structures are f ood-proofed.
  • Number of f ood prone property owners reached.
  • Number of structures insured, f ood proofed, or removed from the f oodplain or f ood prone areas.

FEMA LCPBD IEMA M

BPDD SMC Medium term Medium DH LG

  • Avoid developing within the f oodplain or f oodprone areas, which exposes property and infrastructure to f ood damage risk.
  • Development of the watershed has resulted in an increase in runoff volume and the expansion of the f oodplain, thereby exposing a greater area to risk of f ood damage.
  • Protect the natural drainage system as green infrastructure to prevent f ooding
  • Hold training sessions for municipalities and the development community on the importance of preserving the natural drainage system and the risks and costs associated with developing within the f oodplain or f oodprone areas.
  • Creation of an incentive program to preserve existing f oodplain as open space in perpetuity.
  • Floodplains are preserved by local ordinances.
  • Number of f oodplain preservation ordinances and/or incentive programs.
  • Acres of f oodplain and f ood prone areas preserved.

FEMA LCPBD IEMA M

BPDD SMC Medium term Medium Runoff rate and volume control RR NR HOA BI LM DH LG

  • Watershed problems associated with excessive stormwater runoff rate and volume can be addressed by using conservation development practices and stormwater BMPs.
  • Hold training workshops and presentations on stormwater BMPs, low impact (LID), and conservation development design.
  • Install stormwater BMP demonstration projects.
  • Provide model stormwater BMP standards and ordinances.
  • Municipalities require stormwater runoff volume and rate control BMPs in new development.
  • Increase in voluntary retrof ts of developed areas to reduce runoff rate and volume.
  • Number of participants in workshops and presentations.
  • Number of requests for BMP information / assistance.
  • Number of Section 319 or WMB funding requests for BMPs.
  • Number of developments using stormwater management BMPs or LID techniques.

SMC LCPBD M

BPDD LCSWCD Short term Medium Sanitary system problems RR NR BI HOA

  • Poor sanitary system design, stormwater inf ltration into sanitary sewers, and cross connections between the two have led to sewer backups into buildings.
  • Building owners should install one-way f ow valves in sewer drains, which prevent backups, until the larger infrastructure problems can be solved.
  • Landowners inspect their sanitary sewer lines and correct any I&I problems on their property.
  • Distribute print information to property owners in areas where sanitary sewer backups occur.
  • Building owners install one-way valves in sewer drains.
  • Number of property owners reached.
  • Number of system / drain protection projects.

NSSD LCPBD M

BPDD Short term Medium LG

  • Local governments and the North Shore Sanitary District inspect sanitary sewer lines and interceptors and correct any I&I problems within their systems.
  • Presentations to municipal and agency off cials regarding the impact of cross connections and techniques for f xing problems.
  • Local governments and other responsible parties identify, plan, and correct inf ltration, inf ow, cross connections, and poor designs that have resulted in backups.
  • Number of infrastructure remediation projects completed.

NSSD LCPBD M

BPDD Long term Medium Table 5.16 Information and Education Plan (continued)

236 ISSUE:

A complete and interconnected green infrastructure network is important for protecting watershed resources and natural hydrology.

GOAL:

Protect, restore, and enhance a green infrastructure network of terrestrial and aquatic resources including streams, riparian corridors, wetlands, f oodplains, ravines, depressional areas, and upland resources.

Topic Target Audiences Messages Delivery Mechanism Anticipated Behavioral Changes / Outcome Evaluation Measure Partners Schedule Priority Status Green infrastructure planning and implementation RR NR GP LM LG

  • An interconnected system of open spaces, natural areas, wetlands, f oodplains, streams, and stream buffers can help maintain the hydrologic and biologic health of the watershed.
  • A preserved green infrastructure system is essential for preserving and restoring the health of Lake Michigan.
  • Protected green infrastructure can increase property values for nearby landowners.
  • Preserving natural drainage and storage areas, f oodplains, wetlands, and riparian corridors helps to prevent f ashy stream systems that cause erosion, absorbs excess stormwater, and reduces the risk of f ooding.
  • Provide watershed tours to exhibit green infrastructure elements.
  • Presentations on green infrastructure at community and board meetings.
  • Host land preservation workshops for landowners.
  • Distribute electronic and paper maps that show the green infrastructure system coverage.
  • Voluntary landowner preservation and restoration of green infrastructure elements through integration into private and public development, permanent conservation easements, and/or integration into land management plans.
  • Number of attendees at watershed tours and events.
  • Number of residents and others reached at community meetings.
  • Number of acres of green infrastructure protected.

M SMC LCPBD LCFPD PD CMAP LMWEP IDNR BPDD BCN CW OLP Long term High LM LG OG

  • Everyone needs to do their part and collaborate on preserving green infrastructure important to the health of the watershed. Local governments, park districts, and the forest preserve district are essential partners in the effort to protect green infrastructure elements.
  • Presentations on green infrastructure at board meetings.
  • Provide conservation design

/ Low Impact Development standards to local governments and the development community.

  • Distribute electronic and paper maps that show the green infrastructure system coverage.
  • Communities convey the message to landowners

& developers during the development review & permitting processes.

  • Local governments adopt and incorporate the Green Infrastructure Plan into their Comprehensive Plans.
  • Long term preservation of corridors through easements and acquisition.
  • Communities include green infrastructure preservation in their capital and public works budgets.
  • Communities develop incentives for developers

& landowners to preserve green infrastructure during site design &

development.

  • Number of local governments adopting the Green Infrastructure Plan.
  • Number of communities adopting conservation design

/ Low Impact Development standards.

  • Number of local government off cials and staff reached at community meetings.
  • Number of acres of green infrastructure protected.

M SMC LCPBD LCFPD PD CMAP LMWEP IDNR BPDD BCN CW OLP Long term High Table 5.16 Information and Education Plan (continued)

237 ISSUE:

The watershed contains unique natural resources in need of preservation, restoration and management.

GOAL:

Preserve, restore, and enhance terrestrial and aquatic natural resources.

Topic Target Audiences Messages Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status Natural area

/ wetland management &

restoration GP LM LG S

  • The ecological health of the unique system of wetlands, dunes, and panes found in Illinois Beach State Park and Spring Bluff Forest Preserve, some of which are found nowhere else on earth, depends on the interest and participation of watershed residents and stakeholders in the restoration and management of these systems.
  • Every landowner and land manager can contribute to the ecological and biological quality of the watershed by planting native species, restoring small or large areas of land to native habitat, and restoring the stream corridor and riparian buffer.
  • The watershed contains some of the last remaining undeveloped Lake Michigan lakeshore in Illinois, which supports a host of species including the migratory routes of numerous bird species. The lakeshore deserves continued preservation and improved management to restore this unique resource.
  • Develop electronic media and printed advertisements.
  • Provide natural area tours to exhibit the unique resources.
  • Host natural area restoration and stewardship outings.
  • Install demonstration restoration projects.
  • Deliver presentations at community meetings, garden clubs, and libraries.
  • Distribute a watershed ecology report card.
  • Increased awareness of unique watershed resources and actions to improve them.
  • Increased volunteer involvement in restoration and management activities, both by landowners on private property and by the public in publicly held natural areas.
  • Number of participants in watershed tours and presentations.
  • Number of volunteers participating in restoration events in IBSP, forest preserves, and parks.

SMC LCFPD IDNR CMP LMWEP PD BCN CW OLP DPS NAS USFWS LCPBD Short to Long term Medium to Low RR HOA LM LG

  • Watershed ravines support unique and valuable ecosystems and provide important watershed functions that are being been degraded by encroaching development, stormwater discharge, inappropriate management of edges and slopes, and dumping of yard waste and other debris.
  • Landowners should set development back from ravine edges by a 50 foot, native buffer and restore a healthy layer of ground vegetation within ravines to help stabilize ravine slopes, reduce erosion, and protect property and infrastructure.
  • Host ravine restoration and stewardship outings.
  • Install demonstration ravine restoration projects.
  • Distribute ravine management guidelines and directly contact ravine-side landowners and residents about appropriate practices for these sensitive resources.
  • Ravine-side landowners voluntarily take appropriate management actions such as removing roof and footing drains from the ravines, installing and managing stabilizing ground vegetation, and avoiding land use activities that hasten ravine erosion.
  • Number of participants in ravine restoration events.
  • Number of ravine-side landowners and land managers contacted about proper ravine management.
  • Number of in-ravine plastic pipe discharge points removed or remediated and removed from Action Plan.

SMC LCFPD IDNR LMWEP PD NRCS SWCD CW OLP LCPBD M

Short to Long term High Table 5.16 Information and Education Plan (continued)

238 ISSUE:

Land use and human activity throughout the watershed are degrading water quality in the stream and Lake Michigan.

GOAL:

Improve water quality in streams, lakes, and wetlands by reducing the impacts of land use and development, land management, and modif ed hydrology.

Topic Target Audiences Messages Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status Yard and landscape management RR NR HOA BI LM LG CC

  • Better turf and landscape management practices, which contribute organic matter, nutrients, pet waste, fertilizers, and pesticides to the stream, can improve water quality, reduce landscape maintenance costs, and increase prof tability.
  • Using phosphorous-free fertilizers minimizes nutrient loading to the stream.
  • Pick up animal waste before it can be washed into the stream.
  • Lawn chemicals are killing our streams and rivers.
  • Excessive application of chemicals and fertilizers wastes money.
  • Yard waste smothers benef cial vegetation along the stream.
  • Distribute yard and landscape management guidelines and other print materials.
  • Hold workshops for landowners, land managers, and landscape contractors.
  • Install demonstration natural landscaping projects.
  • Produce advertisements, public service announcements, and cable access spots.
  • Post billboards and posters.
  • Hold presentations at community and HOA meetings.
  • Landowners reduce fertilizer and pesticide application.
  • Landowners dispose of yard waste properly through mulching or bagging.
  • Landowners properly dispose of pet waste.
  • Landscape companies adopt environmentally-friendly management practices.
  • Number of people attending workshops and presentations.
  • Number of demonstration natural landscaping projects.
  • Number of landscape companies adopting environmentally-friendly practices.
  • Number of public reached through media, billboards, and advertisements (i.e.,

circulation).

M IEPA LCHD BPDD GC LCSWCD LMWEP PRL TOWN Short term High Golf course and agricultural land management LM LG

  • Smarter agricultural and golf course management practices can improve water quality and save money.
  • Agricultural operations should plant cover crops and use conservation tillage.
  • Organic agricultural growing operations improve water quality by reducing the input of most detrimental chemicals.
  • Stream and pond buffers with deep rooted vegetation can reduce migration of pollutants to the stream and reduce streambank erosion.
  • Managing goose populations can reduce contribution of animal waste to the stream.
  • Distribute NRCS / SWCD and golf course management guidelines and other print materials, and directly contact agricultural and golf course land owners / managers regarding management practices.
  • Work with Audubon International and strive for Audubon certif cation on golf courses, using Thunderhawk Golf Course as a model..
  • Voluntary installation of stormwater BMPs such as f lter strips.
  • Reduction in the amount of fertilizers and pesticides used.
  • Onsite water resources are buffered with natural vegetation.
  • Number of agricultural and golf course operations / acres using conservation and water quality improvement practices.
  • Number of Audubon certif ed courses.
  • Length and width of stream buffer on agricultural lands and golf courses.

NRCS LCSWCD LCFPD PD AI GC Medium term Medium Urban pollutants /

stormwater BMPs RR NR HOA BI LM LG CC OG S

  • Pollutants such as automotive chemicals, fertilizers, and pet waste collect on urban surfaces and rainwater runoff washes them into the stream, your drinking water, and your swimming beaches.
  • Filtration and inf ltration practices installed on your property can help remove runoff pollutants before they enter the stream, watershed wetlands, and Lake Michigan.
  • Natural vegetation and BMPs can be installed virtually anywhere to help clean urban pollutants form our streams, wetlands, and Lake Michigan.
  • Distribute BMP guidelines to residents, landowners, local governments, consultants, contractors, developers, and homebuilders.
  • Conduct training workshops and deliver presentations at community and professional association meetings.
  • Articles in community newsletters.
  • Install and publicize BMP demonstration projects.
  • New development and redevelopment incorporates stormwater BMPs.
  • Local governments will adopt and enforce stormwater BMP guidelines and standards to reduce runoff and improve water quality.
  • Landowners and developers voluntarily retrof t existing development with stormwater BMPs.
  • Watershed residents reduce the release of urban pollutants into the landscape.
  • Number of communities adopting and enforcing BMP standards and guidelines.
  • Number of participants in educational workshops and meetings.
  • Number of new developments using stormwater BMPs.
  • Number of BMP retrof t projects.

M SMC IEPA LCHD LMWEP Short term Medium Table 5.16 Information and Education Plan (continued)

239 Road, parking lot, and runway management HOA BI LG WA DOTs

  • Runoff from roads, parking lots, and runways impairs water quality by carrying pollutants, including metals and automotive f uids, to the stream.
  • Installing permeable paving practices instead of conventional concrete or asphalt can improve water quality.
  • High chlorides are considered a pollutant of concern in the stream. Chloride levels are increasing in recent years as a consequence of road salt applications.
  • Improved highway and parking lot maintenance, regular sweeping, and lower salt application, can improve water quality.
  • Directly contact departments of transportation and public works departments through one-on-one contact, presentations, and workshops.
  • Distribute print materials to public works departments.
  • Improved highway and parking lot maintenance practices (e.g., use of alternative seal coating products, use of alternative deicing products or procedures).
  • Number of transportation and public works departments reached through contact, workshops and presentations.
  • Number of public works and highway departments adopting environmentally-friendly practices.

DOT IEPA M

Medium term L

Construction site erosion DH LG CC

  • Erosion from construction sites (and other sources) impairs aquatic life habitat in the stream, Illinois Beach State Park, and Lake Michigan.
  • Appropriate and cost-effective soil erosion and sediment control (SESC) measures can reduce the sediment input to the stream.
  • If you see a problem development site, call your local engineer.
  • Provide direct outreach, workshops, and presentations to municipalities regarding erosion control practices, standards, and enforcement.
  • Distribute print materials to developers and homebuilders working in the watershed.
  • Implement Certif ed Erosion Control Specialist programs
  • Improved soil erosion and sediment control measures that reduce the f ow of sediment to streams, lakes, and wetlands.
  • Municipalities enforce and regularly inspect SESC practices.
  • Number of municipalities reached and number of participants in workshops and presentations.

M LCPBD NRCS LCSWCD IEPA Short term Medium Waste and dumping RR NR HOA BI LM LG CC S

  • Dumping of inappropriate substances into the stream or storm sewer seriously impairs water quality.
  • Burning of leaves in ditches or stream corridors contributes pollution to the stream.
  • If you see someone dumping garbage or other waste call your municipality.
  • Hold watershed events such as stream clean ups and storm drain stenciling.
  • Distribute print advertising and door hangers.
  • Publish informational pieces in village newsletters.
  • Reduced dumping into the stream corridor or storm sewer system.
  • Less debris and garbage within the stream corridor.
  • Volunteer participation in stream clean up and stenciling events.
  • Residents properly dispose of household chemicals and f uids in collection centers
  • Number of participants in watershed events.
  • Number of reports of debris dumping..

M Short term H

ISSUE:

Land use and human activity throughout the watershed are degrading water quality in the stream and Lake Michigan. (continued)

GOAL:

Improve water quality in streams, lakes, and wetlands by reducing the impacts of land use and development, land management, and modif ed hydrology.

Table 5.16 Information and Education Plan (continued)

240 Audiences Lead & Partner Organizations A

All audiences AGL Alliance for the Great Lakes LCSWCD Lake County Soil and Water Conservation District BI Businesses and institutions AI Audubon International LCPWD Lake County Public Water District CC Consultants and contractors BPDD Beach Park Drainage District LMWEP Lake Michigan Watershed Ecosystem Partnership DH Developers and homebuilders BCN Bird Conservation Network M

Municipalities (all departments)

DOT Departments of Transportation CMAP Chicago Metropolitan Agency for Planning NAS National Audubon Society GP General public and visitors CW Chicago Wilderness NOAA National Oceanographic and Atmospheric Administration HOA Homeowners associations CBL Corporate and Business Landowners OLP Open Lands Project LG Local governments DH Developers and Homebuilders PD Parks and Recreation Departments LM Land and resource managers DPS Dunesland Preservation Society PRL Private Residential Landowners and Homeowners Associations NR non-riparian residents and landowners FEMA Federal / Illinois Emergency Management Agency NSSD North Shore Sanitary District OG Organizations, committees, and special interests GC Golf Courses TOWN Taskforce on Waukegan Neighborhoods RR Riparian residents and landowners IDNR Illinois Department of Natural Resources T

Townships S

Schools CMP IDNR Coastal Management Program USACE U.S. Army Corps of Engineers WA Waukegan Airport DOT Illinois / Lake County Departments of Transportation USDA U.S. Department of Agriculture IEPA Illinois Environmental Protection Agency NRCS USDA Natural Resources Conservation Service Abbreviations IISG Illinois-Indiana Sea Grant USEPA U.S. Environmental Protection Agency BMP Best Management Practice LCFPD Lake County Forest Preserve District USFWS U.S. Fish and Wildlife Service WPC Watershed Planning Committee LCHD Lake County Health Department WHCAG Waukegan Harbor Citizens Advisory Group LID Low Impact Development LCPBD Lake County Planning, Building, and Development WPA Waukegan Port Authority WMB Watershed Management Board SMC Lake County Stormwater Management Commission YCC Youth Conservation Corps HOA Homeowners Association Schedule Short 0-5 years Meduim 5-10 years Long 10+ years ISSUE:

Development within the watershed will further degrade watershed resources.

GOAL:

Future watershed development uses conservation and Low Impact Development practices.

Topic Target Audiences Messages Delivery Mechanism / Format Anticipated Behavioral Changes / Outcome Evaluation Indicators Partners Schedule Priority Status Low Impact Development HOA DH LG CC

  • Local government and developer commitment to better development approaches, such as Low Impact Development, is important to maintaining the integrity of watershed resources.
  • Distribute guidelines and model ordinances to local governments and developers working in the watershed.
  • Conduct training workshops and deliver presentations at community meetings and professional association meetings.
  • New development uses Low Impact Development practices that protect on-and off-site water resources.
  • Local governments adopt and enforce Low Impact Development standards and guidelines.
  • Developers incorporate conservation design principles into site and stormwater design.
  • Number of municipalities adopting and enforcing conservation design standards and guidelines.
  • Number of participants in workshops and meetings.
  • Number of new developments using LID practices.

SMC LCPBD CMAP LMWEP Medium term Medium Table 5.16 Information and Education Plan (continued)

241