3/4 6-1 AMENDMENT NO. 58

 (DRN 02-912) 3/4.6 CONTAINMENT SYSTEMS 3/4.6.1 PRIMARY CONTAINMENT CONTAINMENT LEAKAGE

 (DRN 02-912)

The Containment Leakage Paths identified on Table 3.6-1 are the Secondary Containment Bypass Leakage paths applicable to Technical Specification 3.6.1.2.

3/4 6-2 AMENDMENT NO. 24, 29, 40 TABLE 3.6-1 CONTAINMENT LEAKAGE PATHS PENETRATION NO SYSTEM NAME VALVE TAG NO.

TEST TYPE 7

Demineralized Water PMUMVAAA151 Bypass/Type C PMUMVAAA152 8

Station Air SA MVAAA908 Bypass/Type C SA MVAAA909 SA ISV9082 SA MVAAA9085 9

Instrument Air IA MVAAA909 Bypass/Type C IA MVAAA910 10 Containment CAPMVAAA103 Type C Atmospheric Purge CAPMVAAA104 11 Containment CAPMVAAA204 Type C Atmospheric Purge CAPMVAAA203 12 Containment Vacuum CVRMVAAA101 Type C Relief CVRMVAAA102 13 Containment Vacuum CVRMVAAA201 Type C Relief CVRMVAAA202 14 Nitrogen Gas NG MVAAA157 Bypass/Type C NG MVAAA158 23 Component Cooling Water CC MVAAA641 Bypass/Type C CC MVAAA644 24 Component Cooling Water CC MVAAA713 Bypass/Type C CC MVAAA710 CCMVAAA7102 Type C

3/4 6-3 AMENDMENT NO. 40,42,55,79, 121 TABLE 3.6-1 (Continued)

CONTAINMENT LEAKAGE PATHS PENETRATION NO.

SYSTEM NAME VALVE TAG NO.

TEST TYPE 25 Fuel Transfer Containment Blind Flange Bypass/Type B

& Fuel Handling Building 26 Chemical & Volume Control CVCMVAAA109 Bypass/Type C Letdown Line CVCMVAAA103 CVCMVAAA1081 Type C 28 Sampling Line from Reactor PSLMVAAA107 Bypass/Type C Coolant Line PSLMVAAA105 29 Sampling Line from PSLMVAAA204 Bypass/Type C Pressurizer Surge Line PSLMVAAA203 30 Sampling Line from PSLMVAAA304 Bypass/Type C Pressurizer Steam Space PSLMVAAA303 31 Waste Management from GWMMVAAA105 Bypass/Type C Containment Vent Header GWMMVAAA104

 (DRN 03-1542, Am. 79; EC-14765, Am. 121) 40 SDC Suction from RCS SI MVAAA405B & SI MVAAA4052B Bypass/Type C SI MVAAA406B Bypass/Type C SI MVAAA407B Bypass/Type C 41 SDC Suction from RCS SI MVAAA405A & SI MVAAA4052A Bypass/Type C SI MVAAA406A Bypass/Type C SI MVAAA407A Bypass/Type C

 (DRN 03-1542, Am. 79; EC-14765, Am. 121)

 (DRN 02-0736, Am. 55) 42 Containment Sump Pump SP MVAAA106 Bypass/Type C Discharge/Post Accident SP MVAAA105 Sample Return SP MVAAA1051 Type C 43 Boron Management Reactor BM MVAAA110 Bypass/Type C Drain Tank Outlet BM MVAAA109 BM MVAAA1091 Type C

 (DRN 02-0736, Am. 55)

Controlled Bleedoff RC MVAAA6061 Type C

3/4 6-4 AMENDMENT NO. 11,2,55 TABLE 3.6-1 (Continued)

CONTAINMENT LEAKAGE PATHS PENETRATION NO SYSTEM NAME VALVE TAG NO.

TEST TYPE 45 CARS Makeup to Containment CARMVAAA101B Bypass/Type C CARMVAAA102B 46 CARS Makeup to Containment CARMVAAA101A Bypass/Type C CARMVAAA102A 47 CARS Exhaust from Containment CARMVAAA202B Bypass/Type C CARMVAAA201B Containment Pressure Exhaust CARMVAAA200B 48 CARS Exhaust from Containmentt CARMVAAA202A Bypass/Type C CARMVAAA201A 49 Containment Atmosphere ARMISV0110 Type C Monitoring Inlet and ARMISV0109 Outlet ARMMVAAA104 ARMISV0103 51 Refueling Cavity FS MVAAA405 Bypass/Type C Purification Inlet FS MVAAA406 53 CVR Non Essential Monitoring Line CVRISV0400 Type C CVRISV0401 Containment Leakage Rate Test LRTMVAAA0400 Type C Connection CVR Essential Instrument Line The CVR Essential line will Bypass/Type C be leak tested from inside containment to its termination point in the instrument cabinet.

 (DRN 02-0736) 59 Safety Injection System SI MVAAA344 Bypass/Type C from SI Tank to Refueling SI MVAAA343 Water Storage Pool SI MVAAA3434 Type C

 (DRN 02-0736) 60 Fire Protection System FP MVAAA601A Bypass/Type C to Reactor Building FP MVAAA602A 61 Fire Protection System FP MVAAA601B Bypass/Type C to Reactor Building FP MVAAA602B

3/4 6-5 AMENDMENT 12 64 TABLE 3.6-1 (Continued)

CONTAINMENT LEAKAGE PATHS PENETRATION NO.

SYSTEM NAME VALVE TAG NO.

TEST TYPE 62 Water from Refueling FS MVAAA416 Bypass/Type C Cavity to RWSP FS MVAAA415 63 Containment Leakage Rate LRTMVAAA109 Bypass/Type C Test Connection Blind Flange 65 Containment Leakage Rate LRTMVAAA202 Type C Test Connection and LRTMVAAA204 CVR Essential Instrument Line The CVR Essential line will be leak tested from inside containment to its termination point in the instrument cabinet Bypass/Type C 66 Hydrogen Analyzer Supply HRAISV0110A Type C and Return HRAISV0109A HRAISV0126A HRAMVAAA128A 67 Hydrogen Analyzer Supply HRAISV0110B Type C and Return HRAISV0109B HRAISV0126B HRAMVAAA128B 71 Demineralized Water CMUMVAAA244 Bypass/Type C CMUMVAAA245 Escape Lock NA Bypass/Type B Personnel Lock NA Type B Electrical NA Type B Penetrations Equipment Hatch NA Type B Expansion Bellows Various Type B 1,2,3,4,25,32,33,43

3/4 6-5a AMENDMENT 12, 64, 99

¨(DRN 04-1244, Am. 99)

THIS PAGE NOT USED (DRN 04-1244, Am. 99)

3/4 6-6 AMENDMENT NO. 02, 58

 (DRN 02-912)

CONTAINMENT SYSTEMS 3/4.6.3 CONTAINMENT ISOLATION VALVES

 (DRN 02-912)

The Containment Isolation Valves listed on Table 3.6-2 are the valves that are applicable to Technical Specification 3.6.3.

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-7 AMENDMENT NO. 48, 55, 98, 101, 104 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP ARM ISV0103 Containment Atmosphere Monitor 49 X

ARM ISV0109 Containment Atmosphere Monitor 49 X

ARM ISV0110 Containment Atmosphere Monitor 49 X

ARM MVAAA104 Containment Atmosphere Monitor 49 X

(DRN 05-39, Am. 98,; 05-1070, Am 104)

BD MVAAA102A Steam Generator Blowdown 5

X(9)

X(9)

BD MVAAA102B Steam Generator Blowdown 6

X(9)

X(9)

(DRN 05-39, Am 98,; 05-1070, Am 104)

BD MVAAA103A Steam Generator Blowdown 5

X X

BD MVAAA103B Steam Generator Blowdown 6

X X

(DRN 02-0736)

BM MVAAA109 Reactor Drain Tank Outlet 43 X

BM MVAAA110 Reactor Drain Tank Outlet 43 X

BM MVAAA1091 Relief Valve(6) 43

(DRN 02-0736)

(DRN 05-998, Am. 101)

CAP MVAAA103 Containment Purge Inlet 10 X

X X

(DRN 05-998, Am. 101)

CAP MVAAA1032 Penetration #10 Leak Rate Test Connection 10 X

CAP MVAAA104 Containment Purge Inlet 10 X

X X

CAP MVAAA203 Containment Purge Outlet 11 X

X X

CAP MVAAA2032 Penetration #11 Leak Rate Test Connection 11 X

CAP MVAAA204 Containment Purge Outlet 11 X

X X

CAR MVAAA101A CARS Makeup 46 X

CAR MVAAA101B CARS Makeup 45 X

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-8 Amendment No. 48, 104 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP CAR MVAAA102A CARS Makeup 46 X

(DRN 05-1070, Am. 104)

CAR MVAAA102B CARS Makeup 45 X

(DRN 05-1070, Am. 104)

CAR MVAAA200B Containment Pressure Exhaust 47 X

X CAR MVAAA201A CARS Exhaust 48 X

CAR MVAAA201B CARS Exhaust 47 X

CAR MVAAA202A CARS Exhaust 48 X

CAR MVAAA202B CARS Exhaust 47 X

X CC MVAAA641 CCW to RCPs and CEDM Cooler 23 X

X(5)

CC MVAAA644 CCW to RCPs and CEDM Cooler 23 X

CC MVAAA710 CCW from RCPs and CEDM Cooler 24 X

X(5)

CC MVAAA7102 Relief Valve(6) 24 CC MVAAA713 CCW from RCPs and CEDM Cooler 24 X

X(5)

CC MVAAA807A CCW to Containment Fan Cooler Units 18 X (4)

X (open)

CC MVAAA807B CCW to Containment Fan Cooler Units 15 X (4)

X (open)

CC MVAAA808A CCW to Containment Fan Cooler Units 20 X (4)

X (open)

CC MVAAA808B CCW to Containment Fan Cooler Units 21 X (4)

X (open)

CC MVAAA822A CCW from Containment Fan Cooler Units 19 X (4)

X (open)

CC MVAAA822B CCW from Containment Fan Cooler Units 22 X (4)

X (open)

CC MVAAA823A CCW from Containment Fan Cooler Units 17 X (4)

X (open)

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-9 Amendment No. 48, 104 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP CC MVAAA823B CCW from Containment Fan Cooler Units 16 X (4)

X (open)

CMU MVAAA244 Demineralizer Water 71 X

CMU MVAAA245 Demineralized Water 71 X

CS ISV0129A Containment Spray 34A & B X

CS ISV0129B Containment Spray 35A & B X

CS MVAAA125A Containment Spray 34A & B X (4)

X (open)

CS MVAAA125B Containment Spray 35A & B X (4)

X (open)

CS MVAAA128A Containment Spray 34A & B X

CS MVAAA128B Containment Spray 35A & B X

CVC ISV0216A CVCS Auxiliary Spray 27 X

CVC ISV0216B CVCS Auxiliary Spray 27 X

CVC ISV0218A CVCS Charging Line 27 X(4)

CVC ISV0218B CVCS Charging Line 27 X(4)

CVC MVAAA103 CVCS Letdown 26 X

X CVC MVAAA1081 Relief Valve(6) 26 CVC MVAAA109 CVCS Letdown 26 X

CVC MVAAA209 CVCS Charging Line 27 X(4)

CVC MVAAA219 CVCS Charging Line (relief function) 27 X

CVC MVAAA401 RCP Bleedoff 44 X

CVR ISV0400 Containment Vacuum Relief Instrument Line 53 X

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-10 Amendment No. 48 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP CVR ISV0401 Containment Vacuum Relief Instrument Line 53 X

CVR MVAAA101 Vacuum Relief 12 X

X (open

)

CVR MVAAA102 Vacuum Relief 12 X

CVR MVAAA201 Vacuum Relief 13 X

X (open

)

CVR MVAAA202 Vacuum Relief 13 X

CVR MVAAA301A CVR Essential Instrument Line 53 X

CVR MVAAA301B CVR Essential Instrument Line 65 X

CVR MVAAA302A Containment Vacuum Relief Essential Instrument Line Excess Flow 53 X

CVR MVAAA302B Containment Vacuum Relief Essential Instrument Line Excess Flow 65 X

EFW MVAAA228A Emergency Feedwater 3

X(2)

(close)

X (open)

EFW MVAAA228B Emergency Feedwater 4

X(2)

(close)

X (open)

EFW MVAAA229A Emergency Feedwater 3

X(2)

(close)

X (open)

EFW MVAAA229B Emergency Feedwater 4

X(2)

(close)

X (open)

FP MVAAA601A Containment Fire Water Header 60 X

FP MVAAA601B Containment Fire Water Header 61 X

FP MVAAA602A Containment Fire Water Header 60 X

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-11 Amendment No. 48 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP FP MVAAA602B Containment Fire Water Header 61 X

FS MVAAA405 Refueling Cavity Purification Inlet 51 X

FS MVAAA406 Refueling Cavity Purification Inlet 51 X

FS MVAAA415 Refueling Cavity Drain 62 X

FS MVAAA416 Refueling Cavity Drain 62 X

GWM MVAAA104 Waste Gas Vent Header 31 X

GWM MVAAA105 Waste Gas Vent Header 31 X

HRA ISV0109A Hydrogen Analyzer 66 X (3)

X(8)

HRA ISV0109B Hydrogen Analyzer 67 X (3)

X(8)

HRA ISV0110A Hydrogen Analyzer 66 X (3)

X(8)

HRA ISV0110B Hydrogen Analyzer 67 X (3)

X(8)

HRA ISV0126A Hydrogen Analyzer 66 X (3)

X(8)

HRA ISV0126B Hydrogen Analyzer 67 X (3)

X(8)

HRA MVAAA128A Hydrogen Analyzer 66 X

HRA MVAAA128B Hydrogen Analyzer 67 X

IA MVAAA909 Instrument Air 9

X IA MVAAA910 Instrument Air 9

X

(DRN 05-880, Am.100)

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES

(DRN 05-880, Am. 100) 3/4 6-12 AMENDMENT NO. 48, 81, 99, 100 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP LRT MVAAA109 ILRT Connection 63 X

LRT MVAAA110 ILRT Connection 63 X

LRT MVAAA201 ILRT Test Connection 65 X

LRT MVAAA2011 ILRT Test Connection 65 X

LRT MVAAA202 ILRT Test Connection 65 X

LRT MVAAA203 ILRT Test Connection 65 X

LRT MVAAA2031 ILRT Test Connection 65 X

LRT MVAAA204 ILRT Test Connection 65 X

LRT MVAAA400 LLRT Test Connection 53 X

(DRN 04-1244, Am. 99)

(DRN 04-1244, Am. 99)

MS MVAAA119A Main Steam Drain 1

X MS MVAAA119B Main Steam Drain 2

X MS MVAAA120A Main Steam Drain 1

X MS MVAAA120B Main Steam Drain 2

X MS MVAAA1244A MSIV Bypass 1

X MS MVAAA1244B MSIV Bypass 2

X

(DRN 03-1738, Am. 81)

(DRN 03-1738, Am. 81)

MS MVAAA401A Steam to Emergency Steam Generator Feed Pump Turbine 1

X (4)

X (open)

MS MVAAA401B Steam to Emergency Steam Generator Feed Pump Turbine 2

X (4)

X (open)

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-13 Amendment No. 48 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP NG MVAAA157 Nitrogen Supply 14 X

NG MVAAA158 Containment N2 Supply 14 X

NG MVAAA412A Main Steam N2 Blanket 1

X NG MVAAA412B Main Steam N2 Blanket 2

X PMU MVAAA151 Demineralizer Water 7

X PMU MVAAA152 Demineralized Water 7

X PSL MVAAA105 RCS Sample 28 X

PSL MVAAA107 RCS Sample 28 X

PSL MVAAA203 Pressurizer Surge Line Sample 29 X

PSL MVAAA204 Pressurizer Surge Line Sample 29 X

PSL MVAAA303 Pressurizer Steam Space Sample 30 X

PSL MVAAA304 Pressurizer Steam Space Sample 30 X

RC MVAAA606 RCP Bleedoff 44 X

RC MVAAA6061 Relief Valve(6) 44 SA ISV9082 Station Air / Instrument Air 8

X SA MVAAA908 Station Air 8

X SA MVAAA9085 Station Air / Instrument Air 8

X SA MVAAA909 Station Air 8

X

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-14 AMENDMENT NO. 48, 68 ACTUATION SIGNALS(1)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP SI MVAAA138A SI from LPSI Pump A to Loop 2B 39 X (4)

X (open)

SI MVAAA138B SI from LPSI Pump B to Loop 1B 37 X (4)

X (open)

SI MVAAA139A SI from LPSI Pump A to Loop 2A 38 X (4)

X (open)

SI MVAAA139B SI from LPSI Pump B to Loop 1A 36 X (4)

X (open)

 (DRN 02-1405)

SI MVAAA14023A

 (DRN 02-1405)

SI from LPSI Pump A to Loop 2B 39 X

X X

SI MVAAA142A SI from LPSI Pump A to Loop 2B 39 X

SI MVAAA142B SI from LPSI Pump B to Loop 1B 37 X

SI MVAAA143A SI from LPSI Pump A to Loop 2A 38 X

SI MVAAA143B SI from LPSI Pump B to Loop 1A 36 X

SI MVAAA225A SI from HPSI A to Loop 1A 55 X (4)

X (open)

SI MVAAA225B SI from HPSI B to Loop 1A 55 X (4)

X (open)

SI MVAAA226A SI from HPSI A to Loop 1B 56 X (4)

X (open)

SI MVAAA226B SI from HPSI B to Loop 1B 56 X (4)

X (open)

SI MVAAA227A SI from HPSI A to Loop 2A 57 X (4)

X (open)

SI MVAAA227B SI from HPSI B to Loop 2A 57 X (4)

X (open)

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-15 AMENDMENT NO. 48, 55, 79, 102, 121 ACTUATION SIGNALS(1)

 (DRN 02-0736, Am. 55)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP SI MVAAA228A SI from HPSI A to Loop 2B 58 X (4)

X (open)

SI MVAAA228B SI from HPSI B to Loop 2B 58 X (4)

X (open)

SI MVAAA241 SIS from HPSI Loop 1A 55 X

(DRN 04-1140, Am. 102)

SI MVAAA2411 SI MVAAA241 Bypass Valve 55 X

(DRN 04-1140, Am. 102)

SI MVAAA242 SIS from HPSI Loop 1B 56 X

(DRN 04-1140, Am. 102)

SI MVAAA2421 SI MVAAA242 Bypass Valve 56 X

(DRN 04-1140, Am. 102)

SI MVAAA243 SIS from HPSI Loop 2A 57 X

(DRN 04-1140, Am. 102)

SI MVAAA2431 SI MVAAA243 Bypass Valve 57 X

(DRN 04-1140, Am. 102)

SI MVAAA244 SIS from HPSI Loop 2B 58 X

(DRN 04-1140, Am. 102)

SI MVAAA2441 SI MVAAA244 Bypass Valve 58 X

(DRN 04-1140, Am. 102)

SI MVAAA343 SIT Drain to RWSP 59 X

SI MVAAA3434 Relief Valve(6) 59 SI MVAAA344 SIT Drain to RWSP 59 X

SI MVAAA405A Shutdown Cooling 41 X

SI MVAAA405B Shutdown Cooling 40 X

 (DRN 03-1542, Am. 79; EC-14765, Am. 121)

SI MVAAA4052A Shutdown Cooling 41 X

SI MVAAA4052B Shutdown Cooling 40 X

SI MVAAA406A Shutdown Cooling Relief Valve 41 SI MVAAA406B Shutdown Cooling Relief Valve 40

 (DRN 03-1542, Am. 79l EC-14765, Am. 121)

 (DRN 02-0736, Am. 55)

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-16 AMENDMENT NO. 48, 55, 57, 98, 102 ACTUATION SIGNALS(1)

 (DRN 02-0736, Am. 55)

VALVE NUMBER FUNCTION Penetration Number CIAS CPIS Manual /

Remote Manual Check Valve SIAS MSIS CSAS EFAS RAS HDP CADP SI MVAAA407A Shutdown Cooling 41 X

SI MVAAA407B Shutdown Cooling 40 X

SI MVAAA506A SI Hot Leg Injection 69 X

SI MVAAA506B SI Hot Leg Injection 70 X

SI MVAAA510A SI Hot Leg Injection 69 X

(DRN 04-1140, Am. 102)

SI MVAAA5101A SI MVAAA510A Bypass Valve 69 X

(DRN 04-1140, Am. 102)

SI MVAAA510B SI Hot Leg Injection 70 X

(DRN 04-1140, Am. 102)

SI MVAAA5101B SI MVAAA510B Bypass Valve 70 X

(DRN 04-1140, Am. 102)

SI MVAAA602A SI from SIS Sump 32 X(7)

(close)

X (open)

SI MVAAA602B SI from SIS Sump 33 X(7)

(close)

X (open)

SP MVAAA105 Containment Sump Pump Discharge 42 X

SP MVAAA1051 Relief Valve(6) 42 SP MVAAA106

(DRN 02-0736, Am. 55)

Containment Sump Pump Discharge 42 X

SSL MVAAA301A Main Steam Sample 1

X(2)

SSL MVAAA301B Main Steam Sample 2

X(2)

(DRN 02-819; 05-39, Am. 98)

SSL MVAAA8004A Steam Generator 1 Blowdown Sample 52 X(9)

SSL MVAAA8004B Steam Generator 2 Blowdown Sample 68 X(9)

(DRN 02-819; 05-39, Am. 98)

SSL MVAAA8006A Steam Generator 1 Blowdown Sample 52 X

SSL MVAAA8006B Steam Generator 2 Blowdown Sample 68 X

TABLE 3.6-2 CONTAINMENT ISOLATION VALVES 3/4 6-17 AMENDMENT NO. 48, 55, 76, 77, 98 TABLE NOTATIONS (1)

Actuation Signals:

MSIS -

Main Steam Isolation Signal SIAS Safety Injection Actuation Signal HDP High Differential Pressure Between Containment and Annulus RAS Recirculation Actuation Signal CSAS -

Containment Spray Actuation Signal EFAS -

Emergency Feedwater Actuation Signal CIAS Containment Isolation Actuation Signal CADP -

Containment-Ambient Differential Pressure Signal CPIS - Containment Purge Isolation Signal (Class 1E Radiation Monitors)

(2)

Valve does not receive CIAS, however a MSIS is considered a containment isolation signal for the purposes of actuation mode.

(3)

Manual Override Provided - CIAS is available but not credited for automatic isolation.

(4)

Containment Isolation Valves whose safety function is to open / remain open post accident are also capable of being closed for containment isolation should that system no longer be required to operate post accident.

(5)

A CSAS is considered a containment isolation signal for the purpose of actuation mode

(DRN 02-0736, Am. 55)

(6)

Relief valve lifts to protect against overpressurization of the penetration.

(DRN 02-0736, Am. 55)

(DRN 02-1809, Am. 76)

(7)

Valve does not receive CIAS, since the valve does not have an automatic containment isolation function. The valve, normally closed, receives a SIAS to close to allow suction from the RWSP. The valve under normal conditions may be opened or closed manually. The valve opens on a RAS to allow suction from the SI sump. After RAS initiation, the valve may be closed remotely and manually to isolate any postulated Emergency Core Cooling System (ECCS) passive leakage.

(DRN 02-1809, Am. 76)

(DRN 03-667, Am. 77)

(8)

The opening of locked or sealed closed containment isolation valves or deactivated automatic containment isolation valves on an intermittent basis under administrative control includes the following considerations:



Stationing an operator, who is in constant communication with the control room, at the valve controls.



Instructing this operator to close these valves in an accident situation.



Assuring that environmental conditions will not preclude access to close the valves and that this action will prevent the release of radioactivity outside the containment.

(DRN 03-667, Am. 77)

(DRN 05-39, Am. 98)

(9)

Valve is not credited for Containment Isolation safety function. Valve receives actuation signal(s) to isolate to prevent inventory loss degrading Steam Generator heat removal and release of radioactivity outside of containment. Tech Spec 3.6.3 is entered if this valve is declared inoperable.

(DRN 05-39, Am. 98)

(DRN 04-972, Am 90) 3/4 6-18 AMENDMENT NO. 90, 91

(DRN 04-972, Am. 90)

(DRN 04-972, Am 90) 3/4.6 CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS MONITORING HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containment hydrogen analyzers shall be OPERABLE.

APPLICABILITY:

MODE 1 and 2.

ACTION:

(DRN 04-1191, Am. 91)

a.

With one containment hydrogen analyzer inoperable, restore the inoperable analyzer to OPERABLE status within 30 days or enter TRM LCO 3.0.3.

b.

With both containment hydrogen analyzers inoperable, restore at least one analyzer to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> and comply with the requirements of ACTION a., or enter TRM LCO 3.0.3.

(DRN 04-1191, Am. 91)

SURVEILLANCE REQUIREMENTS 4.6.4.1 At least once per 31 days each Hydrogen Analyzer shall be demonstrated OPERABLE by performing a CHANNEL CALIBRATION using sample gases containing a nominal:

a.

Zero volume percent hydrogen, balance nitrogen.

b.

9.5 volume percent hydrogen, balance nitrogen.

(DRN 04-972, Am. 90)