PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINAT ION ~ECURITY AGREEMENT.

ES-401 Site-Specific SRO Written Examination Cover Sheet Form ES-401-8 U.S. Nuclear Regulatory Commission Site-Specific SRO Written Examination Applicant Information Name:

Date:

Facility/Unit: Turkey Point Units 3 and 4 Region:

II Reactor Type:

w Start Time:

Finish Time:

Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination, you must a9hieve a final grade of at least 80.00 percent overall, with 70.00 percent or better on the SRO-only items if given in conjunction with the RO exam; SRO-only exams given alone require a final grade of 80.00 percent to pass. You have 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to complete the combined examination.

Applicant Certification All work done on this examination is my own. I have neither given nor received aid.

Applicant's Signature Results RO/SRO-Only/Total Examination Values I

I -- Points Applicant's Score I

I Points Applicant's Grade I

I -- Percent This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN'~ 2015 LOIT (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 1 Given the following conditions:

Unit 3 is operating at 100% power with all systems in automatic.

Which ONE of the following completes the statement below?

Raising ____ will result in a lower final steady state RCP #1 Seal leakoff flow.

A.

Reactor Coolant Drain Tank pressure B.

Volume Control Tank pressure C.

Reactor Coolant Pump Standpipe level D.

Letdown flow This information is controlled by PTN's 2015 torr (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN's 2015 I.OH (1.-15-1) NRC EXAMINAT ION SECURITY AGREEMENT.

QUESTION 2 Given the following conditions:

Unit 4 is in MODE 5.

The Pressurizer is solid with OMS in low pressure operation.

48 RHR loop is in operation.

RCS pressure control is in manual.

Subsequently:

Operator manually lowers demand on TC-4-144A, Letdown Temperature Controller.

Which ONE of the following identifies the plant response with no additional operator action?

A.

NRHX CCW flow decreases.

B.

Shutdown Margin increases.

C.

RCS pressure decreases.

D.

RCS temperature increases.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) r*1N's 2015 LOIT (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 3 Given the following conditions:

Letdown flow is 105 gpm.

Which ONE of the following completes the statement below?

In accordance with 3-0P-047, CVCS-Charging and Letdown, before removing a letdown orifice from service, PCV-3-145, Low Pressure Letdown Controller demand is (1) to maintain pressure at (2) on Pl-3-145.

A.

(1) raised (2) 150 psig B.

(1) raised (2) 300 psig

c.

(1) lowered (2) 150 psig

0.

(1) lowered (2) 300 psig This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by Pl N's 2015 LOrl (L-15-1) NRC EXAMINATION SECURITY AGREEM~: NT.

QUESTION 4 Given the following conditions:

Unit 3 is in MODE 4.

RCS pressure is 370 psig.

Crew prepares to place RHR in service.

MOV-3-750, Loop 3C RHR Pump Suction Stop Valve, is open.

MOV-3-8628, RHR Suction from RWST, is open.

Subsequently:

RCS pressure rises to 475 psig.

MOV-3-751, Loop 3C RHR Pump Suction Stop Valve, will not open.

Which ONE of the following completes the statements below?

MOV-3-751 (1) prevented from opening by RCS pressure.

MOV-3-751 (2) prevented from opening by MOV-3-8628.

A.

(1) is (2) is not

8.

(1) is not (2) is not C.

(1) is (2) is D.

(1) is not (2) is This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 20151.011 (L-15-1) NRC EXAMINA'l ION ~ ECURITY AGREEMEN r.

QUESTION 5 Given the following conditions:

A large break LOCA has occurred on Unit 3.

The 38 4kV Bus is faulted and locked-out.

The crew is performing actions of 3-EOP-E-1, Loss of Reactor or Secondary Coolant.

Conditions are met to isolate the SI Accumulators.

Which ONE of the following completes the statement below and identifies the Accumulator Isolation Valves capable of being closed?

MOV-3-865A and (1)

, Accumulator Discharge Isolation valves, can be closed from

~-

A.

(1) MOV-3-8658 (2) VPB B.

(1) MOV-3-865C (2) VPB

c.

(1) MOV-3-8658 (2) MCC using pushbutton D.

(1) MOV-3-865C (2) MCC using pushbutton This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 20151.0rl (1.-15-1) NRC EXAMINATION SECURITY AGR~: E M E N'I'.

QUESTION 6 Which ONE of the following completes the statements below regarding the operation of the Pressurizer Relief Tank?

PCV-3-473, Nitrogen Regulator, is set to maintain PRT pressure at (1) psig.

PCV-3-473 (2) automatically isolate on a Containment Isolation Phase A.

A.

(1) 6 - 8 (2) will

8.

(1)10-12 (2) will C.

(1) 6-8 (2) will NOT D.

(1)10-12 (2) will NOT This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOl"I (L-15-1) NRC EXAMINAT ION SECURITY AGREEMEN*1.

QUESTION 7 Given the following conditions:

Unit 3 is in MODE 4.

TCV-3-143, UD Demineralizer Divert Valve, is aligned to AUTO.

RHR is in service.

Subsequently:

Annunciator A3/5, L TON DEMIN HI TEMP/FLOW DIVERTED, alarms.

Fl-3-620, local NRHX CCW flow is reading 90 gpm.

Which ONE of the following completes the following statements below?

The LTDN DEMIN HI TEMP alarm setpoint is (1)

In accordance with 3-ARP-097.CR.A, A3/5, the RCO must manually adjust Letdown Temperature.

A.

(1) 135°F (2) TC-3-144A, UD Temp Controller B.

(1)135°F (2) HCV-3-142, RHR Ltdn to eves

c.

(1) 125°F (2) TC-3-144A, UD Temp Controller D.

(1)125°F (2) HCV-3-142, RHR Ltdn to eves (2) to restore This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN ' ~ 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 8 Which ONE of the following identifies the power supply to the Spray Valve Controller for PCV-3-4558, Pressurizer Spray Valve, Loop B?

REFERENCE PROVIDED A.

3001 B.

3023 C.

3P06 D.

3P08 This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by P'I N's 20151.01'1" (1.-15-1) NRC EXAMINAT ION SECURITY AGRH.MEN I.

QUESTION 9 Given the following conditions:

Unit 4 is raising power with Main Generator output at 200 MW.

l&C is performing 4-SMl-086.01, Turbine Emergency Trip Header Pressure Channel Calibration of PS-4-3629.

After discovering PS-4-3629 is calibrated to 45 psig, l&C suspends 4-SMl-086.01 for lunch and leaves work as is.

Subsequently:

Prior to restart l&C verifies PS-4-3630, Turbine Emergency Trip Header Pressure Switch, is tripped prior to recommencing work.

Which of the following completes the sentence below?

The Turbine Emergency Trip Header Pressure Switches are expected to be set at (1)

Continue with (2)

A.

(1) 45 psig (2) 4-EOP-E-O, Reactor Trip or Safety Injection B.

(1) 45 psig (2) 4-GOP-301, Hot Standby to Power Operation C.

(1) 1000 psig (2) 4-GOP-301, Hot Standby to Power Operation D.

(1) 1000 psig (2) 4-EOP-E-O, Reactor Trip or Safety Injection This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOrl' (L-15-1) NRC EXAMINATION SECVRl'I Y AGREEMENT.

QUESTION 10 Given the following conditions:

Unit 4 is at 7% power.

Pressurizer Pressure Channel PT-4-457 fails high.

PT-4-457 is removed from service in accordance with 4-0NOP-049.1, Deviation or Failure of Safety Related or Reactor Protection Channels.

Which ONE of the choices below completes the follow statements?

At Power Trips Blocked light on VPA is (1) for current plant conditions.

With PT-4-457 removed from service, a Safety Injection (2) occur with a subsequent loss of 4P06.

A (1) NOT lit (2) will NOT B.

(1) NOT lit (2) will C.

(1) lit (2) will NOT

0.

(1) lit (2) will This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 ton (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 11 Given the following conditions:

Unit 4 is at 50% power.

PT-4-494, C SIG Pressure Transmitter Channel II, fails high.

The bi-stables for the failed channel are tripped in accordance with 4-0NOP-049.1, Deviation or Failure of Safety Related or Reactor Protection Channels.

Subsequently:

PT-4-495, C SIG Pressure Transmitter Channel Ill, fails low.

Which ONE of the following describes how the plant will respond and why?

An automatic Safety Injection will (1)

Loop C Lo Stm Pressure inputs to the actuation logic are indicating a header pressure 100 psig (2)

S/G pressure.

A.

( 1 ) occur because 2/3 (2) greater than B.

(1) occur because 2/3 (2) less than C.

(1) NOT occur because only 113 (2) greater than D.

(1) NOT occur because only 1/3 (2) less than This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOl'I (1.-15-1) NRC EXAMINATION SECURl"I Y AGREEMEN.I.

QUESTION 12 Given the following plant conditions:

Unit 3 is operating at 100% power.

The breaker to 3A Vital MCC has tripped OPEN.

Which ONE of the following components has lost power?

A.

38 Auxiliary Building Exhaust Fan B.

3A Main Steam Penetration Cooling Fan C.

3A Normal Containment Cooler Fan D.

38 CROM Cooler Fan This information is controlled by PTN's 2015 LOIT (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (1.- 15-1) NRC EXAMINATION SECURI l'Y AGREEMEN"I.

QUESTION 13 Given the following conditions:

Unit 4 is at 100% power.

Subsequently:

A fault occurs on the 4C SG inside containment.

A Reactor Trip and Safety injection occur.

4C SG completely depressurizes.

The Pressurizer is empty.

Containment temperature is 197°F and lowering.

Containment pressure is 15 psig and lowering.

The plant conditions are stabilized.

Which ONE of the following identifies the instrumentation which is NOT designed to operate under the given conditions?

A.

Particulate/Gas Monitors, R-11/R-12 B.

4C SG Pressure Transmitters, PT-4-494/495/496 C.

Pressurizer Level Transmitters, L T-4-459/460/461 D.

4C SG Level Transmitters - Narrow range, LT-4-494/495/496 This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 I.Ori (L-15-1) NRC EXAMINAT ION SECURITY AGREEMEN I.

QUESTION 14 Given the following conditions:

A Unit 3 Reactor Trip and Safety Injection occurs.

RCS pressure is 1000 psig and stable.

RCS subcooling is 45°F.

Containment pressure rises to 16 psig and continues to slowly rise.

Annunciator H5/2, CNTMT ISOLATION ACTIVATED, is in alarm.

The crew is performing 3-EOP-E-O, Reactor Trip or Safety Injection.

The RCO is checking Containment Spray requirements IAW Attachment 3.

Which ONE of the following describes the NEXT required operator action(s) in accordance with ?

A.

Manually initiate Containment Spray using ONLY the Containment Spray pushbuttons.

B.

Manually start the Containment Spray Pumps and open Containment Spray Isolation Valves.

C.

Verify SI is reset. Verify SI Amber Lights on VPB are ALL BRIGHT.

D.

Verify SI is reset and stop ALL RCPs.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN's 20151.01'1 (1.-15-1) NRC EXAMINAT ION SECURIT Y AGREEM ENT.

QUESTION 15 Given the following conditions:

Unit 4 is at 100% power.

Subsequently:

A Reactor trip occurs.

The crew is performing Immediate Operator Actions of 4-EOP-E-O, Reactor Trip or Safety Injection.

The BOP attempts to manually close MSR Main Steam Stop Supply Valves, but the position indications are NOT lit.

Which ONE of the following is required NEXT in accordance with 4-EOP-E-O?

A.

Manually trip the turbine.

B.

Close Main Steamline Isolation and Bypass valves.

C.

Continue verification of MSR Purge valve closure.

D.

Continue verification of Reheater Timing valve closure.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PT N's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMEN I.

QUESTION 16 Given the following conditions:

Unit 3 Reactor power is stable at 8%.

The RCO is manually controlling SG levels at 50%.

Subsequently:

The Unit Supervisor directs raising power to 30%.

During Turbine load increase, the Turbine Control valves opened rapidly.

Reactor power increases to 14%.

All SG level deviations are in alarm.

Which ONE of the following completes the following statements?

The initial SG level deviation alarms occur because SG narrow range levels indicate 5% _ill than programmed level. The RCO (2) required to throttle the Main Feedwater Control valves to maintain SIG levels.

A.

(1) less (2) is B.

(1) greater (2) is

c.

(1) less (2) is NOT D.

(1) greater (2) is NOT This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOl'I (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 17 Given the following:

Unit 4 is at 60% power.

Subsequently:

A Condensate header rupture occurs.

Both Main Feedwater Pumps trip.

After 10 seconds, SG levels are 30% narrow range and lowering.

Which ONE of the following completes the following statements?

An automatic Reactor Trip setpoint (1) currently exceeded. AFW Pumps (2) running.

A.

(1) is (2) are B.

(1) is (2) are NOT

c.

(1) is NOT (2) are.

D.

(1) is NOT (2) are NOT.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PT N's 20151.01'1 (L-15-1) NRC EXAMINA l"ION SECURITY AGREEMEN'I.

QUESTION 18 Given the following conditions:

Unit 3 is increasing power following a refueling outage.

Unit 3 experiences a Reactor trip from 25% power.

The crew completes 3-EOP-E-O, Reactor Trip and Safety Injection, and enters 3-EOP-ES-0.1, Reactor Trip Response.

Pressurizer level is 14% and slowly decreasing.

All Steam Generator Narrow Range levels are between 12% and 15% and slowly rising.

Steam Generators pressures are approximately 990 psig and slowly decreasing.

Tavg is 544°F and slowly decreasing.

RCS pressure is 2125 psig and slowly decreasing.

Which ONE of the following identifies the crew's initial required response in accordance with 3-EOP-ES-0.1 to address the conditions above?

A.

Establish Emergency Boration.

B.

Reduce Auxiliary Feedwater Flow.

C.

Close MSIVs and bypass valves.

D.

Initiate a Safety Injection and return to 3-EOP-E-O.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PT N's 20 IS ton (1.-15-1) NRC EXAMINA'l ION SEC URI l'Y AGREEl\\U:N'I.

QUESTION 19 Given the following conditions:

The Auxiliary Feedwater (AFW) system receives an auto-start signal.

A AFW Pump governor malfunctions and AFW Turbine speed rises.

Which ONE of the following describes the effect of this event?

The A AFW Pump trips on over-speed at (1)

The Train 1 AFW Flow Control Valves will (2)

A.

(1) 5900 rpm (2) remain throttled B.

(1) 5900 rpm (2) fully open C.

(1) 6500 rpm (2) remain throttled D.

(1) 6500 rpm (2) fully open This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOH (L-15-1) NRC EXAMINAT ION SECURI l'Y AGREEMEN"I.

QUESTION 20 Given the following plant conditions:

Unit 3 is in MODE 1.

Unit 4 is in MODE 1.

A lightning strike damages the Unit 3 Startup Transformer.

Which ONE of the following statements correctly describes the required response in accordance with TS 3.8.1.1?

Within one hour, the Unit 3 crew (1) required to demonstrate the OPERABILITY of the Unit 4 Startup Transformer and (2) required to demonstrate the OPERABILITY of the Unit 3 EDGs.

A (1) is (2) is B.

(1) is not (2) is C.

(1) is (2) is not D.

(1) is not (2) is not This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 20151.0IT (L-15-1) NRC EXAMINATION SECURITY AGRn.MEN"I.

QUESTION 21 Which ONE of the following describes the effect of placing the yellow NORMAL/ISOLATE switch to ISOLATE on the 4B HHSI Pump breaker cubicle?

A.

Enables the pump's control switch on the 4KV Breaker cubicle door.

8.

Aligns backup fuses into the 4B HHSI Pump control circuit.

C.

Allows local starts at the SI Pump Room.

D.

Disables all 4B HHSI Pump Breaker protective trip signals.

This information is controlled by l'TN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN ' ~ 201 5 LOIT (L-15-1) NRC EXAMINA'l ION SECURrl V AGREEMEN'I.

QUESTION 22 Given the following conditions:

The 3A RHR Pump is started.

After the pump starts, DC control power is lost.

Which ONE of the following completes the following sentence?

The 3A RHR Pump Breaker 3AA15 ___ _

A.

can NOT be tripped remotely.

The breaker's blue light is extinguished.

B.

can be tripped remotely.

The breaker's blue light is extinguished.

C.

can NOT be tripped remotely.

The breaker's blue light is on.

D.

can be tripped remotely.

The breaker's blue light is on.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h) PTN' s 2015 LOI I (L-15-1) NRC EXAMINATION SECURITY AGREEMEN'I.

QUESTION 23 Given the following conditions:

The 4A EOG is running in parallel with 4A 4KV bus.

The 4A EOG is running at 2800 KW The Varmeter on the 4A EOG Generator Control Panel 4C12A is reading 500 KVAR out.

Subsequently:

The operator locally positions the Voltage Regulator Switch at the 4A EOG Generator Control Panel 4C12A to LOWER.

Which ONE of the following predicts the initial behavior of EOG parameters?

A.

( 1 ) VARs increase (2) current and temperature lower 8.

( 1 ) VARs decrease (2) current and temperature lower C.

( 1 ) VARs increase (2) current and temperature rise 0.

( 1) VARs decrease (2) current and temperature rise This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOI I' (L-15-1) RC EXAMINA"l ION SECURI l'Y AGREEMEN"I.

QUESTION 24 Given the following conditions:

A bus fault has caused 125 VDC Electrical Distribution Bus 3D01 to de-energize.

Which ONE of the following plant components will be directly affected by this loss of DC power?

A.

Loss of Train 2 Feedwater Isolation capability B.

Loss of all 3D Switchgear control power C.

Loss C AFW Pump control and protection D.

Loss of 3A EDG DC power This information is controlled by PTN's 2015 LOIT (L-15-I) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (1.-15-1) NRC EXAMINA rlON SECURITY AGREEMEN I.

QUESTION 25 Given the following conditions:

Unit 3 and 4 are at 100% power Liquid release is in progress IAW O-NOP-061.11C, Controlled Liquid Release From Monitor Tank A.

Subsequently:

Annunciator H1/4, PRMS HI RADIATION, alarms.

Annunciator H1/6, PRMS CHANNEL FAILURE, alarms.

Unit 3 RCO reports no indications are available for Process Radiation Monitor R-18 due to no power.

Which ONE of the following describes the initial required response?

A.

Enter the applicable TS Action Statement.

B.

Enter 3-0NOP-067, Radioactive Effluent Release.

C.

Direct Chemistry to sample effluent in accordance with ODCM.

D.

Direct Chemistry to sample effluent in accordance with 3-ARP-097.CR.H, H1/6.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 I.Ori (L-15-1) NRC EXAMINATION SECURITY AGRU:MEN'I, QUESTION 26 Given the following conditions:

Units 3 and 4 are at 100% power with a normal electrical alignment.

3A and 3B ICW Pumps are running.

Subsequently:

Annunciator 13/4, TRAVELING SCREEN GENERAL TROUBLE, alarms Annunciator 14/2, ICWP A/B/C TRIP, alarms Annunciator 14/4, ICW HEADER A/B LO PRESS, alarms Ultimate Heat Sink Temperature on Tl-3/4-3605 is 96°F.

3A1and3A2 Traveling Screen Wash Pumps are ON.

3A ICW Pump RED light is lit.

Which ONE of the following completes the statement below?

In accordance with 3-ARP-097.CR.I, the RCO (1) start the 3C ICW pump and refer to (2) to address the given conditions?

A.

(1) will (2) 3-0NOP-011.1, Intake Canal Low Level or High Temperature B.

(1) will NOT (2) 3-0NOP-011.1, Intake Canal Low Level or High Temperature C.

(1) will (2) 3-0NOP-019, Intake Cooling Water Malfunction D.

(1) will NOT (2) 3-0NOP-019, Intake Cooling Water Malfunction This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by l'TN's 2015 LOI I (1.-15-1) NRC l*.:\\Al\\llNATION SECURITY AGREE Ml~ NT.

QUESTION 27 Given the following conditions:

Units 3 and 4 are at 100% power.

The 4CM Instrument Air compressor is out for maintenance.

3CM is running in LEAD, 3CD is in LAG, 4CD is in STANDBY-LAG.

The Instrument Air systems are cross-tied.

Subsequently:

Unit 4 Annunciators 16/1, INSTR AIR SYSTEM HI TEMP/LO PRESS, alarms.

Which ONE of the following identifies (1) the setpoint at which CV-4-1605, UNIT 4 Instrument Air Crosstie Isolation Control Valve, closes to protect Unit 4 and (2) the minimum pressure on Pl-4-1444, INST AIR PRESS, if it cannot be maintained, when a Unit 4 Reactor Trip is required per O-ONOP-013, Loss of Instrument Air?

A.

(1) 80 psig (2) 60 psig B.

(1) 80 psig (2) 65 psig C.

(1) 90 psig (2) 60 psig D.

(1) 90 psig (2) 65 psig This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h) r *1N's 201 5 LOI I' (L-15-1) NRC EXAMINATION SECURI l'Y AGREEM EN"I.

QUESTION 28 Given the following conditions:

Unit 3 is in MODE 1.

An emergent Containment Entry is in progress to investigate RCS leakage.

O-ADM-009, Containment Entries When Containment Integrity Is Established, is in effect.

NOTES TS LCO 3.6.1.3 is Containment Air Locks.

Which ONE of the following completes the following statements?

TS LCO 3.6.1.3 (1) satisfied with a single Personnel Hatch door open for transit.

In accordance with O-ADM-009, the RCO (2) required to log the status of Personnel Hatch Inner and Outer Door indication from VPB.

A.

(1) is not (2) is not B.

(1) is (2) is not C.

(1) is (2) is D.

(1) is not (2) is This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOIT (1.-15-1) NRC EXAMINAI ION SECURITY ACREEMEN'I.

QUESTION 29 Given the following conditions:

Unit 3 is in a refueling outage.

The Upper Internals Assembly is being lifted out of the Reactor Vessel to set into the lower cavity.

Subsequently:

84/1, SOURCE RANGE HI FLUX AT SHUTDOWN, alanTis.

The Source Range high flux alarm (1) initiate a containment evacuation alarm.

If flux continues to increase, 84/1 (2) require the operators to initiate Emergency 8oration.

A (1) will (2) does

8.

(1) will (2) does NOT

c.

(1) will NOT (2) does D.

(1) will NOT (2) does NOT This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 ton (L-15-1)

RC EXAMINAI ION SECURI rv AGREEMENT.

QUESTION 30 Given the following conditions:

Unit 4 is in MODE 5.

Letdown is in service.

The RCS is solid.

A plant cooldown and depressurization is in progress.

Which ONE of the following describes the action to lower RCS pressure?

A Raise the setpoint of HCV-4-142, RHR LID to eves.

B.

Raise the setpoint of PCV-4-145, Low Pressure L TON Controller.

C.

Lower the setpoint of HCV-4-142, RHR LID to eves.

D.

Lower the setpoint of PCV-4-145, Low Pressure LTDN Controller.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN's 2015 LOI I' (L-15-1) NRC EXAMINAT ION SECURITY ACREEMEN'I.

QUESTION 31 Given the following conditions:

Unit 3 trips due to Loss of Offsite Power.

3A and 38 EDGs energize their respective 4KV buses.

3-EOP-ES-0.2, Natural Circulation Cooldown, is being implemented.

Automatic SI is blocked in accordance with 3-EOP-ES-0.2.

Subsequently during the cooldown:

Average CET temperature is 586°F and rising.

RCS pressure is 1335 psig and rapidly lowering.

Pressurizer level is 11 % and lowering.

Which ONE of the following actions is required in accordance with 3-EOP-ES-0.2?

A Verify PORVs are closed.

B.

Initiate SI and Phase A C.

Start all available Charging Pumps.

D.

Energize all Pressurizer heaters.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOI r (L-15-1) NRC EXAMINATION SECURITY ACREEM EN I.

QUESTION 32 Given the following conditions:

A Unit 3 Reactor Startup is in progress.

Power level is 1 x 1 o-8 amps.

Subsequently:

120V Vital Instrument Panel 3P07 is lost.

Which ONE of the following completes the following statement?

A Reactor Trip occurs due to the loss of (1)

, and as power lowers below 10E-10 amps_

Lfl._ will energize.

A.

(1) IR Nl-35 (2) SR Nl-31 B.

(1) IR Nl-35 (2) SR Nl-32 C.

(1) IR Nl-36 (2) SR Nl-31 D.

(1) IR Nl-36 (2) SR Nl-32 This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PT N ' ~ 2015 LOI'!' (1.-15-1) NRC EXAMINATION SECURITY AGREEMEN'I.

QUESTION 33 Given the following conditions:

Unit 4 is in MODE 6.

The crew has commenced rod unlatching.

Subsequently:

Annunciator 14/6, CNTMT SUMP HI LEVEL, alarms.

Reactor Cavity water level is 56 feet and lowering.

Bubbles are rising around the outside of the Reactor Vessel.

R-11, Containment Air Particulate Monitor, is in alarm Which ONE of the following completes the following statements based on the given conditions?

Containment Purge Isolation valves (1) required to be closed in accordance with 4-0NOP-033.2, Refueling Cavity Seal Failure.

Normal Containment Coolers are _

_..(2~) __ secured.

A.

(1) are (2) automatically B.

(1) are NOT (2) manually

c.

(1) are (2) manually

0.

(1) are NOT (2) automatically This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOl"I (L-15-1) NRC EXAMINAT ION SECURITY AGREEMENT.

QUESTION 34 Given the following conditions:

A Unit 3 startup is in progress.

The crew prepares to synch the Main Generator to the grid.

Rod Control is in Manual.

Steam Dumps to Condenser Mode Selector Switch is in Manual.

Tavg is 550°F.

Tref is 548°F.

Power Level is 7%.

Subsequently:

The Turbine trips.

Which ONE of the following completes the following sentence for the initial plant response to the Turbine trip?

The Condenser Steam Dumps will __ _

A.

modulate open on the Turbine trip program 8.

quick open on the Turbine trip program C.

quick open on the Steam Header pressure D.

modulate open on the Steam Header pressure This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN'~ 2015 LOI I' (l.-15-1) NRC EXAM I NA rt ON SECURrt Y AGREEMEN*1.

QUESTION 35 Given the following conditions:

Unit 3 is at 100% power Subsequently:

BOP manually trips the Turbine due to high vibration.

Which ONE of the following identifies how secondary system parameters respond?

PT-3-447, Turbine Inlet Pressure, (1) and Condenser Steam Dumps will reduce RCS temperature (2)

A.

(1) lowers (2) to no load Tavg B.

(1) rises (2) to no load Tavg C.

(1) lowers (2) to 5°F of program D.

(1) rises (2) to 5°F of program This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOrl' (L-15-1) NRC EXAMINA l'ION SECURITY AGREEMtNT.

QUESTION 36 Given the following conditions:

Unit 4 is at 100% power.

Main Condenser vacuum is lowering.

The crew enters 4-0NOP-014, Main Condenser Loss of Vacuum.

Which ONE of the following describes ( 1) the initial required action and (2) radiation monitoring capabilities?

A.

( 1 ) Place the Steam Jet Air Ejector Hogging Jet in service.

(2) SJAE SPING is not OPERABLE.

B.

( 1) Place the Steam Jet Air Ejector Hogging Jet in service.

(2) SJAE SPING is OPERABLE.

C.

(1) Place the Standby Steam Jet Air Ejector in service.

(2) SJAE SPING is not OPERABLE.

D.

(1) Place the Standby Steam Jet Air Ejector in service.

(2) SJAE SPING is OPERABLE.

This information is controlled by PTN's 2015 LOIT (L-15*1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOI I (L-15-1) NRC EXAMINA l"ION SECURITY AGREEMEN r.

QUESTION 37 Which ONE of the following is a condition which causes X6/2, RADWASTE BLDG PANEL C46 TROUBLE, to alarm in the Control Room?

A.

Spent Resin Storage Tank High Level B.

Waste Monitor Tank A High Level C.

Reactor Coolant Drain Tank Unit 3 High Level D.

Waste Liquid High Radiation This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h) PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURl"I Y AGREEMENT.

QUESTION 38 Given the following conditions:

Unit 3 startup is in progress per 3-GOP-301, Hot Standby to Power Operation.

Unit 3 is at 25% power and stable.

RCS Boron Concentration is 127 4 ppm.

Turbine is in wr.N Control with the following Control Valve positions:

CV-UL (#1)

CV-LL (#3)

Subsequently:

3%

CV-UR (#2) 14.5% CV-LR (#4) 3%

14.5%

CV-3-1606, A S/G Atmospheric Steam Dump fails open.

Which ONE of the following identifies the INITIAL response of the plant as result of this failure, with no operator action?

A.

Main Generator electrical output will remain constant at 25% with the Turbine in wr.N control.

8.

Reactor Coolant Hot Leg temperature, as read on TR-3-413, rises and results in a decrease in subcooling.

C.

The Turbine Control valves, CV-LL and CV-LR, move to maintain constant Turbine Inlet Pressure.

D.

Reactor Coolant Cold Leg temperature, as read on TR-3-410, lowers and results in a Reactor power rise.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (1. 1) NR EXAMINATION SEC RITY AGREEMEN I.

QUESTION 39 Given the following plant conditions:

Unit 3 trips from 100% power on a spurious SI actuation.

Crew enters 3-EOP-E-O, Reactor Trip or Safety Injection.

RCS pressure is 2150 psig and recovering.

RCS Tavg stabilizes at 535°F.

Which ONE of the following correctly completes the following statement?

To ensure adequate Shutdown Margin, a minimum boration rate of

{1) is required until Shutdown Margin is verified.

From the time of the trip, with no operator action, Shutdown Margin will be

{2) after eighteen (18) hours.

A.

(1) 20 gpm (2) higher B.

(1) 45 gpm (2) higher

c.

(1) 20 gpm (2) lower D.

(1) 45 gpm (2) lower This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENl.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOl"I (1.-15-1) NRC EXAMINAT ION SECURI I Y AGREEMEN"I.

QUESTION 40 Given the following conditions:

A loss of all AC power occurs on Unit 3.

The crew enters 3-EOP-ECA-0.0, Loss of All AC Power.

Pressurizer level is 5% and lowering.

Containment Sump level is rising.

The crew prepares to depressurize the SGs.

Which ONE of the following actions (1) ensures natural circulation or reflux boiling cooling is sufficient and (2) lists the applicable recovery procedure after power is restored?

A.

(1) Verify total AFW flow between 400 and 450 gpm.

(2) 3-EOP-ECA-0.1, Loss of All Power Recovery Without SI Required B.

(1) Maintain >7% Narrow Range Level in at least one SG.

(2) 3-EOP-ECA-0.1, Loss of All Power Recovery Without SI Required C.

(1) Verify total AFW flow between 400 and 450 gpm.

(2) 3-EOP-ECA-0.2, Loss of All Power Recovery With SI Required D.

(1) Maintain >7% Narrow Range Level in at least one SG.

(2) 3-EOP-ECA-0.2, Loss of All Power Recovery With SI Required This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOIT (L-15-1) NRC EXAMINAI ION SECURITY AGREEM EN I.

QUESTION 41 Given the following conditions:

Unit 3 Reactor trips and Safety Injection actuates.

3A 4KV Bus is de-energized due to an overcurrent condition.

All RCPs are tripped in accordance with the Fold-Out page.

The crew is performing Attachment 3 of 3-EOP-E-O, Reactor Trip or Safety Injection.

All other safeguards equipment functions normally.

Which ONE of the following completes the following statement?

In accordance with Attachment 3 of 3-EOP-E-O, the RCO _

_..(....:...1 )...___manually start the Normal Containment Coolers.

The 3B ECC (2) automatically start.

A.

(1) will (2) will B.

(1) will (2) will NOT C.

(1) will NOT (2) will NOT D.

(1) will NOT (2) will This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h) PT N's 2015 l.OIT (1.-15-1) NRC EXAM I NA l'ION SECURI I'\\ AGREEMENT.

QUESTION 42 Given the following conditions:

Unit 4 is at 38% power and stable.

4C Loop RCS Flow Meters are: 86%, 89%, and 91 %.

4C RCP motor frame vibration is 3 mils.

4C RCP Oil Reservoir level W' below normal.

Which ONE of the following identifies the crew response in accordance with 4-0NOP-041.1, Reactor Coolant Pump Off-Normal, to the given conditions?

A.

No actions required to trip 4C RCP or Reactor or reduce load.

8.

A Reactor trip and 4C RCP trip are required.

C.

A Reactor trip is required and 4C RCP trip is NOT required.

D.

A Fast Load Reduction is required.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (1.-15-1) NRC l'XAMINATION SECURITY AGREEMEN I.

QUESTION 43 Given the following conditions:

Unit 3 is at 100% power with 3A Charging Pump running.

HCV-3-121, Charging Flow To Regen Heat Exchanger, is throttled.

Subsequently:

Annunciator A6/5, RCP LABYRINTH SEAL LO LlP, alarms.

Annunciator A5/1, CHARGING PUMP A TRIP, alarms.

3C Charging Pump is started in accordance with 3-0NOP-047.1, Loss of Charging Flow.

The RCO balances Charging and Letdown flows, and establishes a stable VCT level.

RCP Seal Injection flows are 4 to 5 gpm.

Which ONE of the following completes the following sentence?

IAW 3-0NOP-041.01, Reactor Coolant Pump Off-Normal, the first action to address the given conditions is __ _

A.

locally throttle open 3-297A/B/C RCP Seal Injection Valves B.

manually raise 3C Charging pump speed C.

manually throttle closed HCV-3-121

0.

manually throttle open HCV-3-121 This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN'~ 20151.0ff (L-15-1) NRC EXAMINATION SECURrl Y AGREEMENT.

QUESTION 44 Given the following conditions:

Unit 3 is in MODE 4 in 3-GOP-305, Hot Standby to Cold Shutdown.

Unit 3 is cooling down with the 3B RHR loop in accordance with 3-0P-050, Residual Heat Removal System.

3A CCW Heat Exchanger is out of service for maintenance with required pumps in pull-to-lock.

Subsequently:

The 3B CCW pump breaker trips on motor overload, causing an electrical transient resulting in a momentary loss of the 3B 4KV Bus.

3B 4KV Bus power is restored on the 3B EOG.

Which ONE of the following completes the statement below?

Shutdown cooling is restored when 3B RHR pump A.

( 1 ) auto starts from the sequencer (2) auto starts from the sequencer B.

(1) is manually started (2) auto starts from the sequencer C.

(1) auto starts from the sequencer (2) is manually started D.

(1) is manually started (2) is manually started (1) and 3C CCW Pump (2)

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 20151.0rl (1.-15-1) NRC FXAMINATION SECURITY AGREEMENT.

QUESTION 45 Given the following conditions:

Unit 4 is at 80% power.

48 Steam Generator Feed Pump's breaker trips.

Subsequently PC-4-444J, Pressurizer Pressure Controller, does not respond in automatic.

Which ONE of the following completes the sentences below?

PC-4-444J's output is required to be initially (1) in accordance with 4-0NOP-041.5 Pressurizer Pressure Control Malfunction. PORV (2) may be operated by controller PC-4-444J.

A.

(1) raised (2) PCV-4-455C B.

(1) raised (2) PCV-4-456 C.

(1) lowered (2) PCV-4-456 D.

(1) lowered (2) PCV-4-455C This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 Lon (1.-15-1) NRC EXAMINA'l ION SECURI rv AGREEMENT.

QUESTION 46 Given the following conditions:

Unit 3 experiences an Anticipated Transient without Scram (ATWS).

3-EOP-FR-S.1, Response To Nuclear Power Generation/ATWS is in progress.

The RCO is initiating Emergency Boration.

Neither 3A nor 3B Boric Acid Pumps starts.

Which ONE of the following describes the required response to initiate Emergency Boration?

A.

Open MOV-3-350, Emergency Boration Valve.

B.

Close LCV-3-115C, VCT Outlet to Charging Pump Suction.

C.

Close FCV-3-113B, Blender to Charging Pump.

D.

Open 3-356, Manual Emergency Boration Valve.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 I.Ori (L-IS-1) NRC EXAMIN,\\TION SECURITY AGREEMENT.

QUESTION 47 Given the following conditions:

A SGTR occurs on 38 S/G.

3-EOP-E-3, Steam Generator Tube Rupture is in progress.

A cooldown is commenced to target temperature.

Subsequently:

RCS Subcooling lowers to 14 °F with no other accidents in progress.

Which ONE of the following identifies whether or not the RCPs should be secured and why?

A.

Trip the Reactor Coolant Pumps to minimize the potential for RCP damage when an RCS depressurization is initiated.

8.

Trip the Reactor Coolant Pump on the affected loop to minimize RCS inventory loss.

C.

Keep the Reactor Coolant Pumps running to prevent the automatic opening of the SOTA.

D.

Keep the Reactor Coolant Pumps running because a controlled RCS cooldown is in progress.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PT N's 2015 LOIT (1.-15-1) NRC EXAM I NA l'ION S ~. CURl'I Y AGREEMENT.

QUESTION 48 Given the following conditions:

Unit 3 is at 100% power.

3A EOG is out of service for maintenance.

A fault on the Unit 3 Startup Transformer generates a Transformer Lockout and a 3B 4KV Bus Lockout which do not reset.

3-EOP-ECA-0.0, Loss of All AC Power, is in progress.

Which ONE of the following statements identifies (1) the preferred source of power restoration in accordance with 3-EOP-ECA-0.0 and (2) the design basis battery duration?

A.

(1) 3C 4KV Bus (2) 30 minutes B.

(1) 3C 4KV Bus (2) 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> C.

(1) Unit 4 Startup Transformer (2) 30 minutes D.

(1) Unit 4 Startup Transformer (2) 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) f>TN ' ~ 2015 I.Orr (1.-15-1) NRC EXAMINA'l ION SECURITY AGREEMENT.

QUESTION 49 Given the following conditions:

Unit 3 is at 3% power while performing a reactor startup.

Vital Instrument Panel 3P06 loses power.

3-0NOP-003.6, Loss of 120V Vital Instrument Panel 3P06, is in progress.

Which ONE of the following completes the statements below?

The Pressurizer Control Heaters _(1)_. 3-0NOP-003.6 directs the reduction of Charging flow to reduce the PRZ fill rate to prevent _(2)_.

A.

( 1 ) remain on (2) lifting a PRZ PORV B.

( 1) de-energize (2) lifting a PRZ PORV

c.

( 1 ) remain on (2) a High PRZ level trip

0.

( 1 ) de-energize (2) a High PRZ level trip This information is controlled by f>TN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controll('d by PTN' ~ 201 5 LOI I (L-15-1) NRC EXAMINA"l ION ~ECURl"I Y AGREEMl' N r.

QUESTION 50 Given the following conditions:

Unit 3 is in MODE 3.

Vital 480V MCC 3B is out of service.

Subsequently:

Vital DC Bus 3D23 loses power due to a fault on the bus.

The crew is restoring power to DC Bus 3D23 in accordance with 3-0NOP-003.5, Loss of DC Bus 3D23 and 3D23A (3B).

The fault has been isolated.

Which ONE of the following identifies (1) the battery charger that is still OPERABLE and (2) the expected battery charger voltage?

A.

(1) 3B1 (2) 120 volts B.

(1) 3B1 (2) 135 volts C.

(1) 3B2 (2) 135 volts D.

(1) 3B2 (2) 120 volts This information is ('Ontroll('d by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by rTN's 20 IS t orr (1.-15-1) NRC EXAM I NA rt ON SECURITY AGREEMENT.

QUESTION 51 Given the following conditions:

Unit 3 is operating at 95% power.

ICW Header pressure is 8 psig on Pl-3-1619 and Pl-3-1620.

3A 1 and 3A2 Traveling Screen Differential pressures are 12. 7 inches water on R-3-2300 TWS DP Recorder.

TPCW Discharge pressure is 98 psig Pl-3-1468.

CCW Header Supply pressure is 105 psig on Pl-3-640.

Which ONE of the following procedures is required to be entered?

A.

3-0NOP-019, Intake Cooling Water Malfunction B.

3-0NOP-030, Component Cooling Water Malfunction C.

3-0NOP-008, Turbine Plant Cooling Water Malfunction D.

3-0NOP-011, Screen Wash System/Intake Malfunction This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b~ PTN's 2015 I.OH (1.-15-1) NRC EXAMINArlON SECURITY AGREEMENT.

QUESTION 52 Given the following conditions:

Unit 3 is at 95% power.

The TCS MVARs are oscillating.

The Switchyard voltage is stable.

Voltage Regulator Selector Switch is ON.

Subsequently:

The crew enters 3-0NOP-090, Abnormal Generator MW/MVAR Oscillation.

The U3 Turbine Operator reports the Minimum Excitation Module #5 light is lit.

Which ONE of the following describes the operator's response to stabilize the Main Generator?

A.

Raise voltage using the Main Generator AC Voltage Regulator.

B.

Raise voltage using the Main Generator DC Voltage Regulator.

C.

Lower voltage using the Main Generator AC Voltage Regulator.

D.

Lower voltage using the Main Generator DC Voltage Regulator.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h~ PTN"s 2015 I.Ori (L-15-1) NRC EXAMINArlON SECURITY AGREEMENT.

QUESTION 53 Given the following conditions:

3-EOP-ECA-1.2, LOCA Outside Containment, has been entered.

The crew closed MOV-3-744A & B, RHR Discharge to Cold Leg Isolation Valves.

The leak is between the 3B RHR Heat Exchanger and 3-HCV-758, RHR HX Outlet Flow Control Valve.

Which ONE of the following completes the following statement?

In accordance with 3-EOP-ECA-1.2, isolation of the LOCA outside containment can be verified based on (1)

Local operator actions (2) for Alternate RHR to be available for plant cooldown.

A.

(1) increasing RCS pressure (2) are required B.

(1) increasing RCS pressure (2) are NOT required C.

(1) decreasing Auxiliary Building radiation (2) are required D.

(1) decreasing Auxiliary Building radiation (2) are NOT required This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) rTN's 20151.011 (L-15-1) NRC EXAMINAT ION SECURITY AGREE MENT.

QUESTION 54 Given the following conditions:

The Reactor trips due to a loss of offsite power.

A loss of all feedwater occurs.

3-EOP-FR-H.1, Loss of Secondary Heat Sink, is in progress.

A source of feedwater is NOT restored.

The crew is establishing RCS bleed and feed when only one Pressurizer PORV opens.

Which ONE of the following correctly completes the statement below?

Based on these plant conditions, the RCS bleed path is

{1) and the crew should

{2)

, while continuing efforts to re-establish a source of feedwater to the SGs.

A.

(1) adequate (2) depressurize SGs to less than 360 psig B.

(1) adequate (2) open all RCS Vents C.

(1) inadequate (2) depressurize SGs to less than 360 psig 0.

(1) inadequate (2) open all RCS Vents This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b~ PTN' ~ 20151.0n (t-15-1) NRC EXAMINATION SECURI rv AGREEMEN I.

QUESTION 55 Given the following conditions:

Unit 3 trips from 100% power due to a 3A 4KV Bus lockout.

Post trip, a large break LOCA develops.

While performing 3-EOP-ES-1.3, Transfer To Cold Leg Recirculation, 38 RHR Pump trips and cannot be restarted.

Containment pressure peaked at 22 psig and is now 18 psig.

2 Emergency Containment Coolers are running.

RWST level is at 55,000 gallons.

Which ONE of the following completes the statements below?

The Containment Spray Pumps must be operated in accordance with (1)

(2)

Containment Spray Pump(s) is/are required to be operating.

NOTE 3-EOP-FR-Z.1, Response to High Containment Pressure 3-EOP-ECA-1.1, Loss of Emergency Coolant Recirculation A.

(1) 3-EOP-FR-Z.1 (2) One B.

(1) 3-EOP-FR-Z.1 (2) Zero

c.

(1) 3-EOP-ECA-1.1 (2) One D.

(1) 3-EOP-ECA-1.1 (2) Zero This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b)' PTN's 2015 I.Ori' (1.-15-1) NRC EXAMINATION SEC Rl"I Y ACRE ~-M E N ' I QUESTION 56 Given the following conditions:

3-EOP-ECA-2.1, Uncontrolled Depressurization of All Steam Generators, is in progress.

RCS temperature decreases from 547°F to 422°F in the last hour.

The crew adjusts AFW flow.

SG NR levels are all off-scale low.

3A SG Safety Valve reseats.

Which ONE of the following describes the AFW flow requirement and the action for the next procedure transition?

A.

AFW flow is at a minimum of 50 gpm per SG.

Immediately transition to 3-EOP-E-2, Faulted SG Isolation.

B.

AFW flow is at a minimum of 400 gpm per SG.

Immediately transition to 3-EOP-E-2, Faulted SG Isolation.

C.

AFW flow is at a minimum of 50 gpm per SG.

When 3A SG pressure rises, transition to 3-EOP-E-2, Faulted SG Isolation.

D.

AFW flow is at a minimum of 400 gpm per SG.

When 3A SG pressure rises, transition to 3-EOP-E-2, Faulted SG Isolation.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by r *1 N'~ 2015 LOI I (L-15-1) NRC EXAM I NA l'ION SECURITY AGREEMEN'I.

QUESTION 57 Given the following conditions:

Unit 4 is at 50% steady state power.

Tavg is matched with Tref at 562°F.

Automatic VCT makeup is in progress.

TCS is in MW control at 410 MW.

The Rod Motion Control Selector Switch is placed in AUTO after moving Control Bank D to 161 steps.

The Axial Flux Difference is -3 when the Rod Motion Control Selector Switch is placed in AUTO.

Subsequently, a few minutes later:

Unit 4 is at 51% and increasing.

Tavg is 3°F higher than Tref.

TCS is in MW control at 412 MW with Turbine Control Valves closing.

The Axial Flux Difference is -0.5 and trending more positive.

Which ONE of the following completes the following statement?

The conditions identified above are due to a(n)

(1) and the applicable ONOP will subsequently (2) to restore Tavg.

A

( 1 ) inadvertent dilution (2) adjust turbine load B.

(1) continuous rod withdrawal (2) adjust turbine load C.

(1) inadvertent dilution (2) insert control rods D.

(1) continuous rod withdrawal (2) insert control rods This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 20151.0rt (1.-15-1) NRC EXAMINATION SECURITY AGREEMEN I".

QUESTION 58 Given the following conditions:

Loss of Offsite Power occurs on Unit 3.

3A and 38 EDGs are powering the 3A and 38 4KV Buses.

3-EOP-ES-0.4, Natural Circulation Cooldown with Steam Void in Vessel (Without RVLMS) is in progress.

RCS pressure is 1635 psig.

Pressurizer level is 30%.

Prior to depressurizing the RCS, Pressurizer PORV PCV-3-456 fails open.

Which ONE of the following identifies the reason for the initial rapidly increasing Pressurizer level during this event?

A.

The steam space in the Pressurizer collapses allowing more makeup to be injected immediately into the RCS by the HHSI Pumps.

B.

Pressurizer level reference legs flash which results in an increase in indicated level.

C.

Safety Injection Accumulators inject into the RCS which increases Pressurizer level.

D.

Reactor upper head region voiding occurs which results in mass transfer from the Reactor Head to the Pressurizer.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 201 5 LOl'I (L-15-1) NRC EXAMINAl'ION SECURITY AGREEMEN I.

QUESTION 59 Given the following conditions:

Unit 3 is at 100% power.

Subsequently:

E5/3, CONDENSER LO VACUUM, alarms.

Crew enters 3-0NOP-014, Main Condenser Loss of Vacuum.

The Crew commences a Fast Load Reduction IAW 3-GOP-100, Fast Load Reduction.

Operators are evaluating Annunciator B8/1, ROD BANK LO LIMIT which has alarmed.

Which ONE of the following describes NEXT action required by 3-GOP-100?

A.

Place Control Rods in Manual.

B.

Borate the RCS at least 16 gpm.

C.

Slow or stop the load reduction.

D.

Trip the Reactor and enter 3-EOP-E-O.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PT N's 20 IS t on (1.-1!'-I) NRC ~. XAMINAT ION SECURI rv AGREE MEN I.

QUESTION 60 Given the following conditions:

Waste Gas Decay Tank D contains high-activity gas.

Waste Gas Decay Tank D Relief Valve develops a flange leak that is slowly dispersing into the Aux Bldg.

R-14, Plant Vent Gas Monitor, alarms.

Crew.enters 3-0NOP-067, Radioactive Effluent Release.

Which ONE of the following identifies the plant response to an R-14 alarm, if any occurs?

A.

Aux Bldg Exhaust Fans trip.

B.

Aux Bldg Supply Fans trip.

C.

No effect on Aux Bldg or Control Room Ventilation.

D.

Control Room Ventilation shifts to recirculation mode.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PT N's 2015 I.Ori (1.-15-1) NRC EXAMINA'l ION SECURITY AGREEMENT.

QUESTION 61 Given the following conditions:

  • A fire was confirmed in the Cable Spreading Room that was affecting plant equipment.
  • The crew is implementing O-ONOP-105, Control Room Evacuation.
  • All emergency safeguards equipment operates as required.

Which ONE of the following identifies the EDG operation in accordance with O-ONOP-105?

At the point when Control of Shutdown Systems is established, the _____ _

A.

3A EDG will remain loaded

8.

48 EDG will remain loaded C.

3A EDG will need to be shutdown D.

48 EDG will need to be shutdown This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) P'I N'~ 2015 LOl"I (L-15-1) NRC EXAMINA.l ION SECURITY AGREEMEN I.

QUESTION 62 Given the following conditions:

Unit 3 is currently at 100% preparing for a shutdown due to high RCS Activity levels.

Subsequently:

A RCS leak of 50 gpm continues to increase inside containment.

Which ONE of the following identifies which process radiation monitors will show a continued elevated trend after an automatic safety injection actuation?

NOTE R-3-11 Containment Air Particulate R-3-12 Containment Air Gas R-14 Plant Stack Gas A.

R-3-11 Yes, R-3-12 Yes, R-14 Yes B.

R-3-11 Yes, R-3-12 Yes, R-14 No C.

R-3-11 No, R-3-12 No, R-14 Yes D.

R-3-11 No, R-3-12 No, R-14 No This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 ton (L-15-1) NRC l~ XAMlNA rt ON SECURI rv AGREEMEN I.

QUESTION 63 Given the following conditions:

Unit 3 experiences a Safety Injection.

Total AFW flow is throttled to 450 gpm.

The crew transitions from 3-EOP-E-O, Reactor Trip or Safety Injection, to 3-EOP-E-1, Loss of Reactor or Secondary Coolant.

The crew is determining SI Termination criteria with the following:

Containment temperature is 165°F and slowly decreasing.

Pressurizer level is 17% and rising.

RCS subcooling is 58°F and stable.

RCS pressure is 1550 psig and stable.

SG Levels are 5% and rising.

Which ONE of the following identifies the correct operator response and the reason?

A.

Terminate SI since all criteria is satisfied.

B.

Do NOT terminate SI since RCS pressure is too low.

C.

Do NOT terminate SI since SG levels are too low.

D.

Do NOT terminate SI since PZR level is too low.

This information is controlled b)' PTN' s 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 I.Orr (1.-15-1) NRC EXAMINATION SECURITY AGRH.MENT.

QUESTION 64 Given the following conditions:

Unit 3 experiences a major Steam Line Break inside containment concurrent with a Loss of Off-Site Power.

3A and 3B 4KV Buses are powered from the Emergency Diesel Generators.

Containment Pressure Hi signal is actuated.

Containment Temperature is 193°F.

The crew is performing 3-EOP-FR-P.1, Response to Imminent Pressurized Thermal Shock.

Both HHSI and RHR Pumps have been stopped and placed in AUTO.

3A Charging Pump is running with 40 gpm Charging flow.

Letdown is unavailable.

Which ONE of the following is (1) the preferred method to depressurize the plant and (2) the earliest allowable CET subcooling temperature to terminate the depressurization?

A.

(1) Use Auxiliary Spray (2) 28°F B.

(1) Use Auxiliary Spray (2) 82°F C.

(1) Open one Pressurizer PORV (2) 28°F D.

( 1) Open one Pressurizer PORV (2) 82°F This information is controlled by rTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN'~ 20151.0rf (L-15-1) NRC EXAMIN,\\'1 ION SECURI I Y AGREEMENT.

QUESTION 65 Given the following conditions:

Unit 4 Reactor trips due to a loss of offsite power.

The crew performs 4-EOP-ES-0.3, Natural Circulation Cooldown with Steam Void in Vessel (With RVLMS).

Subsequently:

Train 4A RVLMS fails.

Pressurizer level is 6% and lowering rapidly.

Which ONE of the following identifies the required procedural response?

A.

Remain in 4-EOP-ES-0.3, Natural Circulation Cooldown with Steam Void in Vessel (With RVLMS).

B.

Transition to 4-EOP-E-1, Loss of Reactor or Secondary Coolant.

C.

Transition to 4-EOP-ES-0.0, Rediagnosis.

D.

Transition to 4-EOP-E-O, Reactor Trip or Safety Injection.

This information is controlled by PTN's 2015 LOrr (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by P"I N"' 2015 LOI I (L-15-1) NRC EXAMINA I ION SECURITY AGREEMENT.

QUESTION 66 Which ONE of the following identifies the required reviews prior to assuming the Unit 3 RCO responsibility in accordance with O-ADM-202, Shift Relief and Turnover?

A.

Check LMS for quals, review eSOMs for clearances, and review Schedule of Plant Checks and Surveillances (Red Book).

B.

Review TSA log book (TCC Index), review Schedule of Plant Checks and Surveillances (Red Book), and perform a Minimum Equipment List check.

C.

Check Watchstander Out of Service Book, review eSOMs for clearances, and perform a Minimum Equipment List check.

D.

Check Watchstander Out of Service Book, review TSA log book (TCC Index), and review Annunciator Status Log.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) r *1N's 20151.011 (1.-15-1) NRC EXAMINAT ION SECURITY AGREEM EN"I.

QUESTION 67 Which ONE of the following completes the following statements?

The Tech Spec minimum required Spent Fuel Pool water level is (1)

While raising the fuel assembly in the Spent Fuel Pool, the Bridge Crane hoist stops when the load limit of (2) lbs. has been reached.

A.

(1) 57' (2) 2075 B.

(1) 56'10" (2) 2075

c.

(1) 57' (2) 4000 D.

(1) 56'10" (2) 4000 This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h) r T N's 2015 I.Ori (1.-15-1) NRC EXAM I NA I ION SECURIT Y ACREEMEN I.

QUESTION 68 Which ONE of the following identifies the individual(s) who may enter a Guarded Area per OP-AA-102-1003, Guarded Equipment, without requesting permission from the Control Room and first completing OP-AA-102-1003-F01, Protected/Guarded Equipment Work Approval Form?

A Security Officer performing official rounds (1) required to obtain permission.

A Maintenance Supervisor performing a walkdown of a jobsite for an upcoming high risk activity (2) required to obtain permission.

A.

(1) is not (2) is not B.

(1) is not (2) is C.

(1) is (2) is not D.

(1) is (2) is This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy r* 1N'~2015 LOff (1.-15-1) NRC EXAM I NA I ION SECURITY AGREEMl>N r.

QUESTION 69 Given the following plant conditions:

Unit 4 is in MODE 5.

4A RHR loop is in operation.

Which ONE of the following is a criterion for the RCS Loop Filled requirement of O-ADM-051, Outage Risk Assessment and Control?

A.

48 RCP is operating.

8.

Reactor Coolant System pressure is 50 psig.

C.

Unit 4 Steam Generator Wide Range levels are greater than 10%.

D.

Unit 4 Steam Generator Narrow Range levels are greater than 10%.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINAT ION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b} PTN's 2015 LOn (1.-15-1) NRC EXAM I NA l"ION SECURI I Y AGREEMENT.

QUESTION 70 Given the following conditions:

Unit 3 is in MODE 6 with a core onload and containment purge in progress.

The refueling crew is lowering an irradiated fuel assembly into the core, when the assembly is inadvertently dropped.

Annunciators X4/1, ARMS HI RADIATION, and H1/4, PRMS HI RADIATION, are lit.

The crew verifies that R-3-12, Containment Gas Monitor, and Rl-3-14028, Unit 3 Containment Operating Floor, are in alarm.

No other annunciators have been received.

As a result of this event:

A.

8.
c.

D.

( 1) The Containment Evacuation Alarm will be...J1L initiated.

(2) A Control Ventilation Isolation will be __QL_ initiated.

( 1) automatically (2) automatically (1) manually (2) automatically

( 1) automatically (2) manually (1) manually (2) manually This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by rTN's 20151.0rl (L-15-1) NRC EXAMINAT ION SECURI t'Y AGREEMEN I.

QUESTION 71 Given the following conditions:

Unit 3 has just entered MODE 5 for a refueling outage.

All equipment is in a normal alignment for plant conditions.

A containment purge has been initiated using the Unit 4 Purge Supply and Exhaust Fans.

Subsequently:

Containment Radiation Monitor R-3-11, Containment Air Particulate Monitor, alarms.

The crew enters 3-0NOP-067, Radioactive Effluent Release Which ONE of the following identifies the required actions in accordance with 3-0NOP-067?

A.

(1) Check that Unit 4 Purge Supply and Exhaust Fans automatically trip (2) Verify that TS-002, TSC EMER VENT AUTO INITIATE Switch is in INHIBIT B.

(1) Manually stop the U4 Purge Supply and Exhaust Fans (2) Verify that TS-002, TSC EMER VENT AUTO INITIATE Switch is in ENABLE C.

(1) Check that Unit 4 Purge Supply and Exhaust Fans automatically trip (2) Verify that TS-002, TSC EMER VENT AUTO INITIATE Switch is in ENABLE D.

(1) Manually stop the U4 Purge Supply and Exhaust Fans (2) Verify that TS-002, TSC EMER VENT AUTO INITIATE Switch is in INHIBIT This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 72 Given the following conditions:

Unit 3 RCS temperature is 150°F.

Time to boil in the RCS of 35 minutes.

38 RHR pump is Inoperable.

Subsequently, The 3A RHR pump trips and cannot be restarted.

The crew enters 3-0NOP-050, Loss of RHR.

Which ONE of the following completes the statements below?

Containment Closure is required to be completed in (1) minutes, in accordance with 3-0NOP-050.

The equipment hatch is required to be closed with (2) bolts, in accordance with O-ADM-051, Outage Risk Assessment and Control.

A.

(1) 30 (2) four B.

(1) 30 (2) eight

c.

(1) 35 (2) four D.

(1) 35 (2) eight This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h~ rT N' ~ 2015 I.Ori (L-15-1) NRC EXAMINATION SECURI rv AGREEMEN'I.

QUESTION 73 Given the following conditions:

Alignment is complete for Unit 3 hot leg recirculation in accordance with 3-EOP-ES-1.4, Transfer to Hot Leg Recirculation.

Plant conditions are stabilized for the accident in progress.

The highest Critical Safety Function Status Tree (CSFST) is a yellow path on Inventory.

Which ONE of the following identifies the CSFST monitoring requirement in accordance with 3-EOP-F-O, Critical Safety Function Status Trees?

A.

Monitor continuously.

B.

Monitored every 10 to 20 minutes.

C.

Suspend monitoring since conditions are stable.

D.

Suspend monitoring immediately after completing 3-EOP-ES-1.4.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h} PTN's 20151.0IT (1.-15-1) NRC t:XAMINATION SECURI I Y AGREEMENT.

QUESTION 74 Given the following conditions:

Unit 3 is at 100% power.

Work is ongoing in the Unit 3 480V Load Center Rooms.

The foreman requests the fire door between A & B and C & D Load Centers be opened to allow better air circulation for the worker's comfort.

A Fire Protection Impairment has NOT been issued.

In response to the foreman's request, which ONE of the following identifies the policy concerning the propping open of fire doors in accordance with O-ADM-016, Fire Protection Program?

A May be open without compensatory actions as long as work is ongoing.

B.

May be open if an hourly roving fire watch is provided.

C.

Cannot be opened solely for comfort of personnel.

D.

Cannot be opened for more than 30 minutes.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PT N's 2015 Lorr (1.-15-1) NRC E: \\MINAT ION SECURI rv AGREEM EN I.

QUESTION 75 Given the following conditions:

Unit 3 is at 100% power.

Subsequently:

Unit 3 experiences an accident with the following conditions:

Pressure AFW Flow S/GA S/GB S/GC S/GA S/GB S/GC 950 psig and lowering 290 psig and lowering 940 psig and lowering NR Level 21.5 % and lowering 80.3 % and rising 18.6 % and lowering 260 gpm 340 gpm 230 gpm WR Level 55.8% and lowering 55.9% and rising 54.5% and lowering Containment pressure:

21.5 psig and rising Containment Sump level:

36.2 inches and rising Pressurizer pressure:

127 4 psig and lowering Pressurizer level:

1 % and lowering All safeguards equipment is operating as expected.

Based on the indicated parameters, which ONE of the following identifies the initial transition from 3-EOP-E-O,Reactor Trip or Safety Injection?

A.

3-EOP-FR-Z.1, Response To High Containment Pressure B.

3-EOP-E-1, Loss of Reactor or Secondary Coolant C.

3-EOP-E-2, Faulted Steam Generator D.

3-EOP-E-3, Steam Generator Tube Rupture This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN 20151.0ff (L-15-1) NRC EXAMINAl"ION ~ ECURI TY AGREEMENT.

QUESTION 76 Maintaining containment pressure at greater than or equal to the LCO lower pressure limits ensures that

( 1 )

The Tech Spec 336 hour0.00389 days <br />0.0933 hours <br />5.555556e-4 weeks <br />1.27848e-4 months <br /> per calendar year time limit for containment average air temperature between 120 °F and 125 °F (2) allowed to be extended to credit times when containment temperatures are lower.

A.

(1) ECCS systems will have sufficient net positive suction head during the recirculation phase of a design basis accident (2) is NOT B.

(1) ECCS systems will have sufficient net positive suction head during the recirculation phase of a design basis accident.

(2) is C.

(1) the containment structure is prevented from exceeding its design negative differential pressure limit (2) is NOT

0.

(1) the containment structure is prevented from exceeding its design negative differential pressure limit (2) is This information is controlled by PTN's 2015 LOIT (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by rTN's 20151.0n (1.-15-1) NRC EXAMINATION s~:cuRI f'Y AGRH MEN I.

QUESTION 77 Given the following conditions:

Unit 3 is at 100% power.

The following annunciators are lit:

X4/1 ARMS HI Radiation H1/4 PRMS HI Radiation STA reports that for the last 20 minutes the radiation monitors have been reading as follows:

Plant Vent SPING RAD-6304 is in alarm at 2.9E-1 µCi/cc.

Containment Mezzanine Area Radiation Monitor Rl-3-14018 is in alarm at 15 mr/hr.

Letdown Radiation Monitor R-3-20 is in alarm at 255 mr/hr.

U3 Main Steam Line Radiation Monitor MSL-3-6426A is in alarm at 2.6E+2 µCi/cc.

Which ONE of the following is the event classification in accordance with O-EPIP-20101, Duties of the Emergency Coordinator?

REFERENCE PROVIDED A.

Unusual Event B.

Alert C.

Site Area Emergency D.

General Emergency This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 20151.01'1 (l.* 15-1) NRC ~- \\'.A MIN A ! ION SEC Rl'I '\\ AGREEMENT.

QUESTION 78 Given the following conditions:

Unit 3 is at 100% power.

An equalizing charge is in progress on the 3B battery in accordance with O-PME-003.16.

The Common HVAC Unit (E16D) and the North DC Equipment/Inverter Room HVAC Unit (E16E) in the DC Equipment and Inverter Rooms have failed.

DC Equipment and Inverter Rooms and electrolyte temperatures are at 100°F.

O-ONOP-025.3 is in progress.

Which ONE of the following completes the statements below?

The Vital Batteries 3A, 3B, 4A, and 4B and Spare Battery D52 are (1)

. The Shift Manager (2) required to invoke 1 OCFR50.54(x) and (y).

NOTE O-PME-003.16, Individual Cell Equalizing Charge for Vital Batteries 3A, 3B, 4A, and 4B and Spare Battery D52 O-ONOP-025.3, DC Equipment and Inverter Rooms Supplemental Cooling A.

(1) OPERABLE (2) is NOT B.

(1) OPERABLE (2) is C.

(1) NOT OPERABLE (2) is NOT D.

(1) NOT OPERABLE (2) is This information is controlled b) PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PT N's 2015 LOI I (L-15-1) NRC EXAMINATION SECURIT\\' AGREEMEN I.

QUESTION 79 Given the following conditions:

Unit 3 is at 100% power.

3A and 3C ICW Pumps are operating.

Subsequently:

Annunciator 1-4/4, ICW HEADER A/B LO PRESS, alarms.

ICW Header Pressure Indicators, Pl-3-1619 and Pl-3-1620, indicate O psig.

The crew enters 3-0NOP-019, Intake Cooling Water Malfunction.

A pipe break on the 3A ICW /CCW Basket Strainer is isolated.

Which ONE of the following identifies if TS LCO 3.0.3 is met and if a plant shutdown is required to comply with TS after the 3A ICW/CCW Basket Strainer is isolated?

Prior to leak isolation, TS LCO 3.0.3 action(s) __

..... (_1 ~> __ required.

After the 3A ICW/CCW Basket Strainer leak is isolated and repairs are estimated to be completed in 5 days, the Unit __

_.(=2.._) __ in a TS shutdown action statement.

A (1) are (2) is B.

(1) are (2) is NOT C.

(1) are NOT (2) is D.

(1) are NOT (2) is NOT This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled h} PTN's 2015 LOrl' (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 80 Given the following conditions:

Unit 3 was at 100% power with high activity in the RCS when a loss of coolant accident occurs inside Containment.

MOV-3-381, RCP Seal Water Return and Excess Letdown Isolation fails to isolate.

MOV-3-6386, RCP Seal Return Isolation fails to isolate.

MOV-3-626, RCP Thermal Barrier CCW Outlet fails to isolate.

RP reports elevated dose rates in the Auxiliary Building.

The Plant Vent Stack radiation Monitor R-14 has risen from pre-event value of 300 cpm to current value of 6000 cpm.

Which ONE of the following choices identifies the minimum action required to isolate the Containment penetrations and if a release is in progress in accordance with O-EPIP-20134, Offsite Notifications and Protective Action Recommendation?

A.

  • close MOV-3-381 and MOV-3-626.

No Release B.

close MOV-3-381 and MOV-3-626.

Release

c.
  • close MOV-3-6386 and MOV-3-381.

No Release D.

close MOV-3-6386 and MOV-3-381.

  • Release This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) Pl"N'~ 2015 LOIT (l.-15-1) NRC EXAMINA.l ION SECURI I' AGREEMEN'I.

QUESTION 81 Given the following conditions:

Unit 3 is in MODE 2.

A 2 gpm pinhole leak on the piping is discovered upstream of the first off RCS valve, 3-9548, RCS Hot Leg Sample Valve.

3-9548 is closed.

Which ONE of the following states the required Tech Spec actions in accordance TS LCO 3.4.6.2, Reactor Coolant System Operational Leakage?

REFERENCE PROVIDED A.

No Technical Specification actions are required.

8.

Isolate the sample line with 1 valve within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> AND no further Technical Specification actions are required.

C.

Place Unit 3 in at least MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> AND be in MODE 5 within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

D.

Isolate the sample line with 2 valves within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> AND no further Technical Specification actions are required.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN's 2015 LOrl (L-15-1) NRC EXAMINA I ION SECURITY AGREEMENT.

QUESTION 82 Given the following conditions:

Unit 3 is operating at 100% power.

3-0SP-059.10, Determination of Quadrant Power Tilt Ratio is complete.

The Quadrant Power Tilt Ratio (QPTR) is 1.08.

Which ONE of the following completes the statements below?

Power is required to be lowered to (1) within two hours.

The Technical Specification action requires that the QUADRANT POWER TILT RATIO be calculated at least once (2) until either the QUADRANT POWER TILT RA TIO is reduced to within its limit, or THERMAL POWER is reduced to less than 50% of RATED THERMAL POWER.

A.

(1) 76 %

(2) per hour

8.

(1) 76 %

(2) every two hours C.

(1) 82 %

(2) per hour D.

(1) 82 %

(2) every two hours This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN ' ~ 20151.0rl (1.-15-1) NRC ~.. ' \\MINA'l ION SECURIT\\ \\GREEMENT.

QUESTION 83 Given the following conditions:

Unit 4 is at 100% power.

4C Steam Generator tube leakage is 20 gpd.

Slowdown radiation monitor R-4-19 is Inoperable.

Which ONE of the following completes the statements below?

In accordance with the Offsite Dose Calculation Manual (ODCM), blowdown operations (1) with R-4-19 Inoperable.

R-4-19 inoperability affects the automatic isolation of (2)

A.

(1) are not permitted (2) CV-4-6275A/S/C, Slowdown Isolation Valves S.

(1) may continue with periodic grab samples (2) CV-4-6275A/S/C, Slowdown Isolation Valves C.

(1) are not permitted (2) FCV-4-6278A/S/C, Slowdown Flow Control Valves D.

(1) may continue with periodic grab samples (2) FCV-4-6278A/S/C, Slowdown Flow Control Valves This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN's 2015 LOH (L-15-1) NRC E\\'.AMINA l'ION SECURITY AGREEMEN I.

QUESTION 84 Given the following conditions:

Unit 3 is at 100% power.

Unit 4 is at 10% power.

B AFW Pump is OOS for repairs.

Subsequently:

The switchyard is de-energized during severe weather.

All emergency buses are powered from their respective EDGs.

C AFW Pump trips on start.

MOV-3-1405 fails to automatically open.

The crew completed the reading of 3-EOP-E-O, Rx Trip or Safety Injection, Foldout Page.

Which ONE of the following completes the information below regarding the action to perform and why?

The Unit Supervisor __

.._{ 1

...... l __ to start A AFW Pump and establish 340 gpm AFW flow to Unit 3 to minimize --~<~2~> __

NOTE MOV-3-1405, 3C Stm Supply To Aux Feedwater Pumps AFSS-3-006/007, AFW Steam Supply Cross-connect valves A.

(1) directs manually opening MOV-3-1405 (2) thermal stress due to excessive cooldown

8.

(1) must direct realigning AFSS-3-006 and 007 (2) the effects of an RCS heatup to prevent opening PZR PORVs C.

( 1) directs manually opening MOV-3-1405 (2) the effects of an RCS heatup to prevent opening PZR PORVs D.

(1) must direct realigning AFSS-3-006 and 007 (2) thermal stress due to excessive cooldown This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) r *1N's 2015 1.0l'r (L-15-1) NRC' EXAMINAT ION SECURIT\\ AGRU*:MEN I.

QUESTION 85 Given the following conditions:

Unit 3 is MODE 4, on RHR.

Subsequently:

Pressurizer level is off-scale low.

Annunciator H6/2, RHR HX HI/LO FLOW, alarms.

R-3-11, Containment Air Particulate Monitor, is in alarm.

The crew enters the appropriate off normal procedure.

A leak is discovered downstream of RHR Discharge To Cold Leg Isolation Valves, MOV-4-744A and MOV-4-7448.

Which ONE of the following completes the statements below?

The steps containing the operator actions to isolate the leak are in (1)

The ONOP will (2) during leak isolation.

A.

(1) 3-0NOP-041.3, Excessive Reactor Coolant System Leakage (2) stop the RHR pumps

8.

(1) 3-0NOP-041.3, Excessive Reactor Coolant System Leakage (2) NOT stop the RHR pumps C.

(1) 3-0NOP-041.7, Shutdown LOCA [Mode 3(Less than 1000 psig) or Mode 4]

(2) stop the RHR pumps D.

(1) 3-0NOP-041.7, Shutdown LOCA [Mode 3(Less than 1000 psig) or Mode 4]

(2) NOT stop the RHR pumps This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 201 5 1.011 (1.-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 86 Given the following conditions:

Unit 3 is at 95% power.

3A CCW Pump is OOS for maintenance.

38 CCW Pump tripped.

3C CCW Pump is running.

The Unit Supervisor reviews DCS - RCP Detailed Data Summary (see attached).

Which ONE of the following identifies the earliest notification requirement, if any, for the given plant conditions after the crew has completed initial actions?

REFERENCE PROVIDED A.

No notifications are required.

B.

15 minute to the State and Counties.

C.

4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to the Nuclear Regulatory Commission Operations Center (NRCOC).

D.

8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> to the Nuclear Regulatory Commission Operations Center (NRCOC).

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b} rTN's 20151.01'1 (1.-15-1) NRC EXAl\\llNA I ION SECURITY AGREEMEN I.

QUESTION 87 Given the following conditions:

Unit 3 is at 100% power.

Subsequently:

The Reactor fails to automatically trip on low SG levels following the loss of 3A SGFP.

3-EOP-FR-S.1, Response to Nuclear Power Generation/A TWS, is in progress.

Annunciator B9/4, ROD CONTROL URGENT FAILURE, alarms.

Local actions to trip the reactor are unsuccessful.

3B Boric Acid Transfer pump is running.

Prior to manipulation, MOV-3-350, Emergency Boration Valve, position red and green lights are found NOT lit.

CET temperature is 1250°F and rising.

Which ONE of the following identifies (1) the required action and (2) whether PARS are required for this event?

REFERENCE PROVIDED A.

(1) Closing LCV-3-114B, Blender Flow to VCT.

(2) PARS required.

B.

(1) Opening 3-356, Manual Emergency Boration valve (2) PARS NOT required.

C.

(1) Closing LCV-3-114B, Blender Flow to VCT.

(2) PARS NOT required.

D.

(1) Opening 3-356, Manual Emergency Boration valve.

(2) PARS required.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by r *1 N' ~ 20 I 5 ton (L-15-1) NRC EX,\\l\\llNATION SECURrl' AGREEMENT.

QUESTION 88 Given the following conditions:

Unit 4 is in MODE 3 The switchyard lost power 18 minutes earlier and remains de-energized.

4A EDG is running and its output breaker red light is lit.

4B EDG is running and its output breaker green light is lit.

4B RCP has no light indication.

The station blackout tie permissive blue light is off.

The Unit Supervisor enters 4-0NOP-004.3, Loss of 4B 4KV Bus, and has verified that control room evacuation is not required.

Which ONE of the following identifies the whether Attachment 1, 4B 4KV Bus Stripping, is required in accordance with 4-0NOP-004.3 and the correct Emergency Classification?

REFERENCE PROVIDED A.

ls NOT Alert B.

Is

  • Alert
c.

Is Unusual Event D.

ls NOT Unusual Event This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOI I (L-15-1) NRC EXAMINA I ION SECURITY AGREEMEN'I.

QUESTION 89 Given the following conditions:

Unit 3 is at 100% power.

I 5/4, TPCW HI TEMP/LO PRESS, alarms.

POV-3-4882, ICW to TPCW Heat Exchanger, is found closed.

The crew enters 3-0NOP-019, Intake Cooling Water Malfunction.

Subsequently:

Action is taken to locally open POV-3-4882 with the handwheel.

Which ONE of the following identifies the following Technical Specification requirements?

When POV-3-4882 is locally opened, Unit 3 -~(_1 )..___ a 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> action statement.

POV-3-4882 has an instrument air accumulator designed to maintain the valve position for (2) hours.

A.

(1} enters (2) two B.

(1} enters (2) four

c.

( 1 } does NOT enter (2) two D.

( 1 } does NOT enter (2) four This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PrN ' ~ ZOIS LOl'I (L-15-1) NRC EXAMINATION SECURITY AGREEJ\\IEN'I.

QUESTION 90 Given the following conditions:

A safety injection has occurred due to lowering pressurizer level and pressure.

3-EOP-E-O, Reactor Trip or Safety Injection, is in progress Containment radiation parameters are normal.

R-14, Plant Vent, and Rl-3-14158, Aux Bldg North N/S Corridor, are in alarm.

Which ONE of the following identifies the first transition out of 3-EOP-E-O based on the given conditions and the action to be taken?

(1) is entered and isolating (2) is the first action taken.

A.

(1) 3-EOP-ECA-1.1, Loss of Emergency Coolant Recirculation (2) MOV-3-869, Safety Injection Hot Leg Isolation B.

(1) 3-EOP-ECA-1.2, LOCA Outside Containment (2) MOV-3-869, Safety Injection Hot Leg Isolation C.

( 1) 3-EOP-ECA-1.1, Loss of Emergency Coolant Recirculation (2) MOV-3-750/751, RHR Suction Stop valves D.

(1) 3-EOP-ECA-1.2, LOCA Outside Containment (2) MOV-3-750/751, RHR Suction Stop valves This information is controlled by PTN's ZOIS LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 20151.01"1 (L-15-1) NRC EXAMINATION SECURl'I Y AGREEMENT.

QUESTION 91 Given the following conditions:

The Control Room is evacuated due to smoke and a fire in a cable tray.

Unit Supervisor is performing Attachment 13, Unit Supervisor from O-ONOP-105.

Unit 3 RO initiates an Emergency Boration.

All CROM Fans are running.

The Unit 3 RCO starts Attachment 22, Unit 3 Cool Down from ASP.

Containment temperature is 185°F.

Core Exit Thermocouple (CET} temps are at 700°F.

Reactor Coolant System (RCS) pressure is 2220 psig.

Which ONE of the following strategies does the Unit Supervisor next direct to mitigate the given conditions?

O-ONOP-105, Control Room Evacuation 3-EOP-FR-C.2, Response to Degraded Core Cooling A.

Continue in O-ONOP-105, and then direct dumping steam while maintaining 20% to 50% corrected SIG levels.

B.

Continue in O-ONOP-105, and then direct a RCS depressurization to allow ECCS Accumulator injection.

C.

Immediately tran&ition to 3-EOP-FR-C.2, and then direct dumping steam while maintaining 20% to 50% corrected SIG levels.

D.

Immediately transition to 3-EOP-FR-C.2, and then direct a RCS depressurization to allow ECCS Accumulator injection.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PT N' ' 2015 LOI I (l.* 15-1) NRC EXAMINAT ION SECURrn \\GREEMEN'I.

QUESTION 92 Given the following conditions:

A Unit 4 Steam Generator Tube Rupture occurs.

Due to equipment failures, the crew is performing actions contained in 4-EOP-ECA-3.2, SGTR With Loss Of Reactor Coolant - Saturated Recovery Desired.

All CSF Status Trees are GREEN with the exception of the following:

o Core Cooling - YELLOW path for 4-EOP-FR-C.3, Response To Saturated Core Cooling o

Inventory - YELLOW path for 4-EOP-FR-1.2, Response To Low Pressurizer Level Which ONE of the following describes the required implementation of procedures for this event, and the reason?

A.

4-EOP-ECA-3.2 directs steps to be performed in accordance with 4-EOP-FR-1.2 to restore the Inventory.

8.

4-EOP-ECA-3.2 directs steps to be performed in accordance with 4-EOP-FR-C.3 to restore the Core Cooling.

C.

Remain in 4-EOP-ECA-3.2. The actions contained in 4-EOP-FR-C.3 and 4-EOP-FR-1.2 conflict with 4-EOP-ECA-3.2 actions.

D.

Remain in 4-EOP-ECA-3.2. Implementation of YELLOW Path procedures is not allowed when using Emergency Contingency Action procedures.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) PTN's 2015 LOl'I (1.-15-1) NRC 1-.XAMINATION SECURI l'Y AGR E l~ Ml<:NT.

QUESTION 93 Given the following conditions:

During a 3-EOP-ES-0.3 cooldown, RVLMS indicates the Plenum is less than 40%.

NOTE 3-EOP-ES-0.3, Natural Circulation Cooldown With Steam Void In Vessel (With RVLMS) 3-EOP-FR-1.3, Response To Voids In The Reactor Vessel Which ONE of the following is the required strategy and the basis?

--~<~1

..... ) __ is used to re-pressurize the RCS. The basis for this action is __

_.(.:2.1....) __

A.

( 1 ) 3-EOP-FR-1.3 (2) to prevent the void from expanding into the S/G U-tubes 8.

(1) 3-EOP-FR-1.3 (2) to raise CET subcooling to greater than 19°F to collapse the void C.

(1) 3-EOP-ES-0.3 (2) to prevent the void from expanding into the S/G U-tubes D.

(1) 3-EOP-ES-0.3 (2) to raise CET subcooling to greater than 19°F to collapse the void This information is controlled by PTN' s 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) r*1N's 2015 LOH (L-15-1) NRC EXAMINATION SECURITY AGREFMENT.

QUESTION 94 Given the following conditions:

Unit 3 is in MODE 3 following a refueling outage.

3-0SP-202.1, Safety Injection/Residual Heat Removal Flowpath Verification, Attachment 2 is in progress.

Prior to exceeding 380°F, the Shift Manager is verifying that the preceding steps of 3-GOP-503, Cold Shutdown to Hot Standby, are complete prior to signing the Shift Manager Verification Point.

Which ONE of the following identifies whether subsequent 3-GOP-503 procedure steps, past the Shift Manager Verification Point, may be performed?

A.

Steps may NOT be performed until 3-0SP-202.1, Attachment 2 is complete.

B.

Steps may NOT be performed without the Plant General Manager concurrence.

C.

Steps may be performed if they will not heat the RCS temperature above 380°F.

D.

Steps may be performed if they does not affect the Sl/RHR Flowpath verification.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOI I' (L-15-1) NRC EXAM I NA I ION SECURI I Y AGREEl\\IENT.

QUESTION 95 Which ONE of the following completes the statements below?

The Emergency Coordinator (EC) is responsible to ensure the NRC is notified within (1) minutes of declaration of an emergency.

The Emergency Coordinator (EC) task of making Offsite Protection Action Recommendations (PARS)

(2) be delegated to the TSC Operations Manager.

A.

(1) 15 (2) can NOT B.

(1) 15 (2) can C.

(1) 60 (2) can NOT D.

(1) 60 (2) can This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled hy PTN' ~ 20151.011 (1.-15-1) NRC F.XAMIN \\ TION "iECURITY AGREEl\\IEN'I.

QUESTION 96 Given the following conditions:

Unit 4 is in MODE 3, following a spurious trip.

The A AFW Pump fails during the trip.

The AFW system has NOT been re-aligned.

Which ONE of the following identifies if a MODE change is allowed or required, and why?

REFERENCE PROVIDED A.

Entry into MODE 1 and 2 is allowed, with no restrictions.

B.

Entry into MODE 1 *and 2 is allowed. Restore the A AFW pump to Operable within 30 days, or place the unit in MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in MODE 4 within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

C.

Entry into MODE 2 is not allowed. Restore the A AFW pump to Operable within 30 days, or place the unit in MODE 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in MODE 4 within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

D.

Entry into MODE 2 is not allowed. Restore the A AFW pump to Operable within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, or place the unit in MODE 3 within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in MODE 4 within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by r *1N's 2015 LOI I (L-15-1) NRC EXAMINA"l ION SECURITY AGREEM ENT.

QUESTION 97 Given the following conditions:

Unit 4 is in a refueling outage.

A Control Room annunciator is to be defeated for a clearance order on equipment required to be operable for the current plant conditions.

In accordance with O-ADM-219, Annunciator Response Procedure Usage, which ONE of the choices below completes the following:

O-OSP-200.5, Attachment 1, Defeated/Out-Of-Service Annunciator Checklist, retained in the Equipment Out of Service Index.

The applicable portions of O-OSP-200.5, Miscellaneous Tests, and Operating Evolutions, for Defeated/Out-Of-Service Annunciators must be completed ____ _

A.

is NOT; within ONE hour B.

is NOT; prior to defeating the annunciator C.

is; within ONE hour D.

is; prior to defeating the annunciator This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOI I (L-15-1) NRC EXAMINATION SECURITY AGREEMEN'I,

QUESTION 98 Given the following conditions:

An Emergency Response Team is being briefed on a mission to rescue a worker who has suffered a sprained ankle.

Radiation Protection estimates each team member will receive a total dose (TEDE) of 11 rem and a thyroid dose of 6 rem while performing this rescue.

In accordance with O-EPIP-20111, Re-entry, which ONE of the following correctly describes (1) the estimated dose as compared to the Emergency Worker Exposure TEDE limit and (2) the guidance for issuing Potassium Iodide (Kl) to the team members?

A.

(1) is within the Emergency Worker Exposure TEDE limit; (2) Kl should be issued to prevent iodine absorption B.

(1) is within the Emergency Worker Exposure TEDE limit; (2) Kl should NOT be issued C.

(1) exceeds the Emergency Worker Exposure TEDE limit; (2) Kl should NOT be issued D.

( 1) exceeds the Emergency Worker Exposure TEDE limit; (2) Kl should be issued to prevent iodine absorption This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled b) P'I N 2015 LOrI (L-15-1) NRC EXAMINATION SECURITY AGREEMEN'I.

QUESTION 99 Given the following plant conditions:

Annunciator C4/4 PZR HI PRESS TRIP alarms and is confirmed valid Unit 3 reactor is at 100%

CETs are 1225 °F and rising.

Which ONE of the following completes the statements below?

In accordance with 3-FRP-S.1, Response to Nuclear Power Generations/ATWS, the crew unsuccessfully tried tripping the reactor by opening the

( 1 )

The Unit Supervisor is required to transition to (2)

A.

( 1 ) 3A and 38 motor generator input and output breakers (2) SACRG-1, Severe Accident Control Room Guideline Initial Response 8.

(1) 3A and 38 motor generator input and output breakers (2) 3-EOP-FR-C.1, Response to Inadequate Core Cooling C.

(1) feeder breakers to 3A and 30 480V Load Centers (2) SACRG-1, Severe Accident Control Room Guideline Initial Response 0.

(1) feeder breakers to 3A and 30 480V Load Centers (2) 3-EOP-FR-C.1, Response to Inadequate Core Cooling This information is controlled by PTN's 2015 LOIT (L-15-I) NRC EXAMINATION SECURITY AGREEMENT.

PTN L-15-1 NRC EXAM This information is controlled by PTN's 2015 LOff (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

QUESTION 100 The following plant conditions exist:

A SITE AREA EMERGENCY was declared 37 minutes ago.

The emergency response facilities are NOT activated.

The communicator has made the notification to the State and NRC.

Conditions are stabilized and the event no longer meets the emergency action level criteria.

Who is responsible for de-escalation of the classification?

A.

Recovery Manager B.

Emergency Coordinator C.

Nuclear Division Duty Officer D.

Emergency Control Officer This information is controlled by PTN's 2015 LOIT (L-15-1) NRC EXAMINATION SECURITY AGREEMENT.

.,!ocl

~

'ete' TURKEY POINT PLANT

~,.."' i\\O Sl 1

s NUCLEAR TRAINING

'J. E ttO '.' ~t,C L.. ;~y l~I DEPARTMENT

'1-n

~-

l=PL KEV

~

NAME: fTN L-/S-/ f1'Rc 5a111 -Si2<D 1..

2

~

NJ!!

00~

3..

SOC. SEC. #:

~

66 4

C..s.h. w_6-I I..

B6 5..

DEPT: I /1'.l i~

DEPT. SUPV.

L6 6

96 7..

DATE:

02 } '3_/_j_.5_

S6 8

v6 9

EXAM TITLE: P,-J\\J L :;--1_ A/i c :E"&iyv\\ - Sib

~

£6 10

£ X C{M ke\\J l6 11 fli.

EXAM NO.:

.. ~6 12

~

I 06 13..

TOTAL POINTS: _

/OCJ

._ 6B 14 BB 15..

I hereby certify that I will take the exam and abide by the rules of LB 16

~

conduct provided by the proctor.

99 17 N//1-iJ'!r SB 18

~

179 19 Student's Signature Date

£9 20

~

lB 21

~

LB 22..

OB 23 -

Student signature below certifies that the graded exam has been

~ 6L reviewed:

24

_,, BL 25 -

/I} ',4-

~

LL 26 -

Student's Signature Date 9L 27..

SL 28

~

49 PL 29 *

£L 30

_.. GL 31 ca Grader's Name:

_j}/11 LL 32

~

OL 33 Score:

69 34 NIA

~

B9 35 ~

L9 36..

Pflnt Signature Date 49 99 37 S9 38 49

~

pg 39..

~

£9 40

~

(;9 41 QC Grader's Name:

L9 t 42 -

IV/A-

~

09 43 Score:

Ct 6S 44

/\\) j4 BS 45 49 LS 46..

Print Signature Date 9S lE 47 SS 48 Njg PS 49

~

RAR IE#:

£S 50

~

~

ZS.. LS i- 04 J. '- 'l>c~ 'A' CUt\\d '(,' l\\.CC e\\> teJ U.5 ~rr-ect

~

ea

  • io..w \\>C.5t-t)l.ww\\ C'()\\"V'\\W-.Sv.. t, A3>4