CNL-15-018, Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report

From kanterella
(Redirected from ML15030A485)
Jump to navigation Jump to search
Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report
ML15030A485
Person / Time
Site: Browns Ferry, Watts Bar, Sequoyah  Tennessee Valley Authority icon.png
Issue date: 01/30/2015
From: James Shea
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
CNL-15-018
Download: ML15030A485 (20)


Text

Tennessee Valley Authority, 1101 Market Street. Chattanooga, Tennessee 37402 CNL-15-018 January 30, 2015 10 CFR 50.4 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington , D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296 Sequoyah Nuclear Plant, Units 1 and 2 Facility Operating License Nos. DPR-77 and DPR-79 NRC Docket Nos. 50-327 and 50-328 Watts Bar Nuclear Plant, Unit 1 Facility Operating License No. NPF-90 NRC Docket No. 50-390

Subject:

The Tennessee Valley Authority (TVA) Nuclear Power Gro up Commercial Grade Dedication Recovery Project - January 2015 Status Report

Reference:

1. TVA letter to NRC, "Additional Information Regarding March 28, 2013, Public Meeting With NRC Regarding The Tennessee Valley Authority's (TVA)

Commercial Grade Dedication Recovery Project," dated April 30, 2013 (ML13123A163)

2. TVA letter to NRC, 'The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project Plan - July 2013 Status Report," dated July 31 , 2013 (Ml13220A102)
3. TVA letter to NRC, "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - October 2013 Status Report," dated October 31, 2013(ML13309A747)
4. TVA letter to NRC, "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2014 Status Report," dated January 31 , 2014(ML14038A139)

Nuclear Regulatory Commission CNL-15-018 Page 2 January 30, 2015

5. TVA letter to NRC, "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - April 2014 Status Report," dated April 30, 2014(ML14126A843)
6. TVA letter to NRC, "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - July 2014 Status Report, " dated July 31 , 2014(ML14212A748)
7. TVA letter to NRC, "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - October 2014 Status Report," dated October 31 , 2014(ML14304A724)

The purpose of this letter is to provide the Nuclear Regulatory Commission (NRC) staff with the January 2015 Commercial Grade Dedication (CGD) Recovery Project Status Report. Previous status reports were provided in References 2 through 7.

In Enclosure 2 of the Reference 1 letter, TVA provided the NRC with a TVA Nuclear Power Group CGD Recovery Project Action Plan Summary that included two commitments. In Commitment 1, TVA committed to complete a comprehensive evaluation of commercial grade dedicated items installed between September 1995 and November 2011 for the operating fleet, and correct any identified deficiencies by December 31 , 2014. In Commitment 2 , TVA committed to provide the NRC with periodic written updates regarding progress of the project by the last day of July, October, January, and April of each year until the project is completed, beginning with the first written report to be filed by July 31, 2013.

On December 15, 2014, TVA representatives from Engineering and Licensing contacted the NRC staff via telephone to discuss TVA's plans to formally change the completion date for the CGD Recovery Project commitment in the next update, scheduled for the end of January 2015, and acknowledged that TVA will continue with quarterly updates until the CGD Project is completed. As discussed, the completion date for the CGD Recovery Project is now May 31 , 2015.

During the December 15, 2014, telephone conversation , a TVA representative explained that of "the 218 remaining Catalog Identifiers (CATIDs), 172 have associated reports that will be finalized by December 31 , 2014, documenting acceptance and that there are 46 CATIDs that are still being evaluated from a seismic critical characteristic perspective. "

No issues have been identified that resulted in declaring plant equipment to be inoperable.

The enclosure to this letter provides the TVA Nuclear Power Group CGD Recovery Project -

January 2015 Status Report.

Nuclear Regulatory Commission CNL-15-018 Page 3 January 30, 2015 There are no new regulatory commitments contained in this letter. Should you have any questions, please contact Tom Hess at (423) 751 -3487.

y,

. Shea v President, Nuclear Licensing

Enclosure:

Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report

Nuclear Regulatory Commission CNL-15-018 Page 4 January 30, 2015 cc (Enclosure):

NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant NRC Senior Resident Inspector - Sequoyah Nuclear Plant NRC Senior Resident Inspector - Watts Bar Nuclear Plant NRR Project Manager - Browns Ferry Nuclear Plant NRR Project Manager - Sequoyah Nuclear Plant NRR Project Manager - Watts Bar Nuclear Plant

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report INTRODUCTION:

During a public meeting with the Nuclear Regulatory Comm ission (NRC) staff on March 28, 2013, TVA described a broad set of actions being taken by the TVA Nuclear Power Group (NPG) to address commercial grade dedication (CGD) program issues identified by the NRC in Watts Bar Unit 2 construction-related Integrated Inspection Report 05000391/2011607, dated September 30, 2011 , and Integrated Inspection Report 05000391/2011610, dated February 3, 2012. To further address commercial grade dedication program issues, TVA made a commitment to complete a comprehensive evaluation of commercial grade dedication items installed between September 1995 and November 2011 for the operating fleet, and correct any identified deficiencies by December 31 , 2014. On December 15, 2014, TVA representatives from Engineering and Licensing contacted the NRC staff via telephone to discuss TVA's plans to formally change the completion date for the CGD Recovery Project commitment in the next update, scheduled for the end of January 2015, and acknowledged that TVA will continue with quarterly updates until the CGD Project is completed. As discussed, the completion date for the CGD Recovery Project is now May 31 , 2015.

In a letter to the NRC dated July 1, 2013,1 TVA informed the staff that TVA Nuclear Power Group Commercial Grade Dedication Recovery Project Plan was approved for implementation and briefly described the plan. The CGD Recovery Project Plan describes the evaluation process being used to determine whether an adequate basis exists, is documented, and provides reasonable assurance that a commercial grade item to be used as a basic component will perform its intended safety function. The plan establishes the scope of the project, identifies the number of specific items that must be evaluated, and describes the grouping of items for evaluation by type, supplier, and time frame of procurement. The plan also describes documentation that TVA will generate during the evaluation process for items that are installed and/or currently in inventory; for items that are obsolete and through regular preventive maintenance are no longer installed in safety related applications; and for inventory items that have not been purchased or installed since Part 21 , Reporting of Defects and Noncompliance, of Title 10 of the Code of Federal Regulations (1 OCFR) was amended in 1995.

From April 2013 to April 2014, the CGD Recovery Project Team identified 22,340 unique Catalog Identifiers (CATIDs) that have been generated for CGD items across the TVA Nuclear Power Group Fleet since September 1995. Of this population , 17,343 unique CATIDs have been identified to be either not purchased or not installed. Therefore, the remaining 4 ,997 unique CATIDs have been either purchased or installed in a TVA nuclear plant and require evaluation, as described in the CGD Recovery Project Plan.

The CGD Recovery Project is evaluating the unique CATIDs in groups where possible. In many cases, several CGD packages have been generated for the same unique CATID due to the number of years of plant operations under evaluation.

The status provided below documents the progress to date based on accounting for the applicable number of unique CATIDs.

1 TVA letter to NRC , "The Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project Plan ," dated July 1, 2013(Ml13189A133)

E 1 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PROGRESS TO DATE:

As of April 4, 2014, the TVA CGD Recovery Project Weekly Report indicated that from a population of 17,343 CATIDs that were either not purchased or not installed, all 17,343 CATIDs have been verified via an additional data search.to not exist in inventory or in the operating units. This completes the verification and documentation of CATIDs that were either not purchased or not installed.

As of January 15, 2015, from a population of 4,997 CATI Os that were purchased and are either in inventory or installed, 4973 CATIDs have been assessed against project plan review criteria ,

including the critical characteristics for acceptance (CCA), and were found to be acceptable.

However, preliminary results for 148 seismic CATIDs are acceptable pending final validation of installed locations and/or component configuration. The remaining 24 CATIDs have been assessed against project plan review criteria , including the CCA, and were found to be acceptable with the exception of seismic CCA information.

During the effort to evaluate commercially dedicated parts against the applicable CCA, an additional gap was identified where critical characteristics to confirm seismic qualification/suitability were not adequately documented. This gap can be characterized as failing to adequately document the equipment seismic/structural qualification of the replacement items in accordance with TVA Nuclear Engineering Department seismic procedures and design standards. The assessment of seismic CCA information for seismic sensitive CATIDs is ongoing. Additional actions and resources are being applied to address the additional scope of seismic CCA information.

Based on progress made to date, the TVA Nuclear Power Group Commercial Grade Dedication Recovery Project is on track to meet the extended May 31 , 2015, commitment date for project completion.

UPDATE ON PREVIOUSLY IDENTIFIED ISSUES:

The status of previously identified testing failures is summarized in the Table below. A testing failure is initially documented in a Service Request (SR), then further documented and evaluated in a Problem Evaluation Report (PER), under the corrective action program.

PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

July31 , 2013 SR 755044 CAE345C Overload Failed current carrying Purchased new heaters for Closed (PER 762570) Heaters due to incorrect test testing to revised criteria.

current All items passed testinq.

July 31 , 2013 SR 755092 BKG441M 1-1/4 Inch Failed dimensional test Used three point Closed (PER 762593) Copper - use of single measurement technique &

Couplings measurement point additional analyses to accept Items.

E 2 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SRJPER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

October 31 , PER 793398 BDH517E Fuses Failed current clearing Based on EPRI TR- Closed 2013 PER 826788 20A, 250V testing by 25% longer 017218, Revision 1, Time Delay than criteria Guideline for Sampling in the Commercial-Grade Jtem Acceptance Process.

the remaining inventory was scrapped . No record of safety related (SR) application was identified.

However, if installed in SR application, the 25% longer clearing time would not degrade the component function during accident scenarios. PER 885910 to address additional 10 CFR 21 considerations.

October 31 , PER 794799 BXA282G Pressure Failed acceptance Defective pressure switch Closed 2013 PER821184 Switch criteria for was scrapped. PER configuration, 885910 to address operating response. additional 10 CFR 21 repeatability, and considerations.

weiqht October 31 , PER 793399 CKA398K Brass Failed threading Installed fitting acceptable Closed 2013 PER 821992 Tubing Tee testing based on completed Fittings conditional dedication .

PER 885910 to address additional 10 CFR 21 considerations.

October 31 , PER 784385 CKJ806N Hydraulic Failed flash point test Revised flash point criteria Closed 2013 PER 793529 Fluid to lower value. Material PER 828658 acceptable for end use aoolications.

January 31 , PER 827195 CRE543B Breather Failed testing criteria Material dispositioned as Closed 2014 Caps for material type acceptable with no effect on ooerabilitv.

January 31 , PER 827194 CRF195B Vent Caps Failed testing criteria Material dispositioned as Closed 2014 for material and acceptable with no effect dimension on operability. Additional dimensional inspection desiqnated for this item.

January 31 , PER 821151 BJV743J Overload Failed testing criteria Failed criteria Closed 2014 Heaters for resistance and inconsequential to overload dimensions heater operation. Pre-installation testing verifies proper operation. PER 885910 to address additional 10 CFR 21 considerations.

E 3of16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

January 31, PER 826067 BVT390J Cable Failed testing criteria Deficient parts would have Closed 2014 Splices for wire size been self-revealing during dimensions installation . Material will be scrapped. PER 887333 to address additional 10 CFR 21 considerations.

January 31, PER 826791 AWT096Y Fuses Failed testing criteria 1 of 30 fuses tested did not Closed 2014 0.125A for current carrying meet current carrying capacity capability - fuse opened before thermal stability was reached. If installed, this fuse would have likely fa iled during normal operation and/or surveillance testing.

PER 885910 to address additional 10 CFR 21 considerations.

January 31, PER 828735 BAG502L Fuses Failed testing criteria Test results reviewed and Closed 2014 1.6A for current clearing accurate. No record of time safety-related (SR) application was identified.

Work orders initiated to replace non safety-related applications. Remaining inventory scrapped per EPRI TR-017218, Revision 1, guidance. PER 932364 to address additional 10 CFR 21 considerations.

January 31, PER 830725 BVC946R Terminal Failed testing criteria Based on new information, Closed 2014 Lugs for material type item meets manufacturer's specifications.

Manufacturing process involves copper barrel material and brass spade materi al. Mixed material manufacturing was not apparent based on initial review of product data sheets. New PER 905272 was generated to review test results and revise procurement documents to correct material type.

January 31 , PER 830726 BYB188W Terminal Failed testing criteria Test method revised based Closed 2014 Lugs for material type on manufacturer's specifications. Material retested and verified to meet criteria. Material acceptable to revised packaQe.

E 4of16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

January 31 , PER 8238 13 BYM865Q Terminal Failed testing criteria Revised material attributes Closed 2014 Lugs for material type for copper concentration and item found acceotable.

January 31, PER 8251 15 CFF597C Polyethylene Failed testing criteria Retested tubing to proper Closed 2014 Tubing for pressure integrity test pressure and found acceptable.

January 31, PER 826424 BYL2968 Insulating Failed testing criteria Initial criteria not critical. Closed 2014 Tape for tensile strength Revised criteria and retested for tape thickness and di-electric strength .

Item found acceptable.

January 31 , PER 820855 CCA611R Pulley Failed testing criteria Incorrect material specified Closed 2014 Bushings for material type based on current manufacturing. Material acceptable to originally supplied material type.

January 31 , PER 825131 BQX704E Mandrel Pop Failed testing criteria Incorrect material specified Closed 2014 Rivets for material type for mandrel. Revised material type and tested additional samples for acceptance.

January 31, PER 823816 CPV360D Cable Failed testing criteria Package revised to test Closed 2014 Splices for material type material to the applicable ASTM standard versus providing minimum copper content for material type.

Material tested to more specific criteri a and found acceptable.

January 31, PER 828659 CEH294T Pressure Failed testing criteria Incorrect data sheet in Closed 2014 Switch for weight package. Revised package to include correct data sheet.

January 31, PER 823818 BRN013X Resistors Failed testing criteri a Incorrect dimensional Closed 2014 for dimensions tolerances applied.

Revised CGD package and amended dimensional test report for acceptance.

January 31, PER 824184 CFP436V Brass Failed testing criteria Revised criteria to brass Closed 2014 Tubing for material type alloy. A brass alloy plus Unions pressure testing supported acceptance.

January 31, PER 821083 CGX850P Brass Failed testing criteria Revised criteria to brass Closed 2014 Tubing for material type alloy. A brass alloy plus Unions pressure testing supported acceptance.

E 5 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SRJPER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

April 30, 2014 PER 845971 CFB485C HFA Relay Failed seismic criteria Evaluate and document Closed resolution of the non-conformance of 18 HFA relays. An additional relay from the lot tested to application specific criteria and passed seismic criteria , resolving the non-conformance issue. '

April 30, 2014 PER 842727 BVT503M Resistor Failed dimensional Error occurred when Closed criteria selecting the critical characteristic dimension for resistor length and lead length. Resistors passed revised criteria.

April 30, 2014 PER 842713 BLA3520 30Amp Failed current clearing Expanded sample testing Closed Fuse time per EPRI TR-0172 18, Revision 1, resulted in acceptance of the fuse lot.

April 30, 2014 PER 842712 BLA345A 200Amp Failed current clearing Expanded sample testing Closed Fuse time. per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

April 30, 2014 PER 842728 CFD755Y 35 Amp fuse Failed current clearing Incorrect criteria initially Closed time specified . PEG Package revised. Additional testing provided acceptable results.

April30, 2014 PER 842703 BWA522 1.8 Failed leakage current Expanded sample testing Closed w microfarad and working voltage per EPRI TR-017218, Capacitor Revision 1, resulted in acceptance of the capacitor lot.

April 30, 2014 PER 853916 CAC064M Resistor Failed dimensional Incorrect tolerance revised. Closed criteria Test report amended resulting in acceptance of the resistor lot.

April 30, 2014 PER 842702 APD135T Access Failed dimensional Dimensional criteria revised Closed Valve criteria based on end use considerations. Re-inspection of entire lot to revised criteria resulted in acceptance of the lot.

April 30, 201 4 PER 860042 ADM954A 35Amp Failed current clearing No material installed. Closed Fuses time Remaining material scrapped to prevent issue to the plant. PER 887333 to address additional 10 CFR 21 considerations.

E 6 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

April 30, 2014 PER 845579 BLN398N #22 AWG to Failed measurement Inspection verified a mixed Closed

  1. 14 AWG indicating a mixed bin bin of material. 100%

Splice (reducing 22 AWG to inspection performed to 14 AWG splice and remove deficient material non-reducing 14 AWG and scrap. Remaining to 14 AWG splice material sent to lab for mixed together) physical inspection.

PER 885910 to address additional 10 CFR 21 considerations.

April 30, 2014 PER 842128 CVD369R Exhaust Failed volumetric flow 10CFR21 Failure Closed Valves rate criteria Reportability was evaluated and determined that conditions identified in PER 887333 are not reportable.

No operability impact exists for the four valves (1 -FCV-001-0004, -0011 , -0022, and -0029) since CATID CVD369R was never installed April 30, 2014 PER 862599 CFM395R Sleeve Failed dimensional Incorrect dimensional Closed Fitting criteria tolerances specified and dimensions recorded beyond significant digits.

Material re-inspected to correct dimensional tolerances and accepted.

PER 932364 to address additional 10 CFR 21 considerations.

April 30, 2014 PER 844628 CAA979N Overload Failed contact The failure occurred during Closed Relay resistance - open testing and failed as "open" circuit contact, therefore, the relay is no longer viable for use.

This condition would be self revealing during the installation and testing process. Initially, a quantity of 10 relays from the lot of 19 were tested, with one resulting failure. Based on the one fai lure, the entire lot will be tested. PER 932364 to address additional 10 CFR 21 considerations.

April 30, 2014 PER 841713 CGJ609B Resistor Failed dimensional The resistor length and Closed PER 892013 criteria lead length dimensional deficiencies were found acceptable.

E 7 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

April 30, 2014 PER 848255 BYL400P 8 Amp Fuse Failed dimensional Material found acceptable Closed criteria based on new tolerance information. CGD documents revised and material accepted. PER 885910 to address additional 10 CFR 21 considerations.

April 30, 2014 PER 845243 CBB278A Resistor Failed power rating of The resistors are normally Closed resistor used in panel light indicators, where the resistors drop the circuit voltage to a value appropriate for the indicating lamp. Failed lots were scrapped and one lot found acceptable.

Procurement documents found acceptable for future purchases. PER 887333 to address additional 10 CFR 21 considerations.

April 30, 2014 PER 867205 BVA247Y 7.5 Amp Failed current clearing Expanded sample testing, Closed Fuse time per EPRI TR-017218-R1 ,

resulted in an additional fuse failing acceptance criteria. PER 891992 was issued to document and evaluate issue. Issue history evaluated for installed applications.

Inventory material not acceptable and scrapped .

Tes ting criteria and procurement documents determined to be acceptable for new procurement.

April 30, 2014 PER 867221 BDL448P 700 Amp Failed current clearing New acceptance criteria Closed Fuse time established based on UL 248-1. Expanded sample testing per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

April 30, 2014 PER 867220 BYF689H 15Amp Failed current clearing Expanded sample testing Closed Fuse time per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

E 8 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES In itial Status SR/PER CATID Item Failure Disposition Status Report Date Num ber Description Description (Open/

Closed)

April 30, 2014 PER 863778 BYV699G 0.5 Amp Failed current clearing Inventory material not Closed Fuse time acceptable and scrapped .

Tes ting criteria and procurement documents determined to be acceptable for new procurement. PER 885910 to address additional 10 CFR 21 considerations.

July 31, 2014 PER 842729 CHB326L Check Valve Failed material type Host component Closed determined to be QA-3 and material downgraded and scrapped.

July 31, 2014 PER 882 147 BLR987K 4 Amp Fuse Failed current clearing Initial fai lure due to Closed time incorrect criteria.

Additional sample testing to revised criteria resulted in acceptable results.

July 31, 2014 PER 899140 ARB566W 200 Amp Failed current carrying Material not acceptable for Closed Fuse capacity plant use. History search identified no material installed in safety related components.

July 31 , 2014 PER 896388 CGJ885H Resistor Failed resistance and Material not acceptable for Closed power rating plant use and scrapped .

No changes identified for procurement documents.

July 31, 2014 PER 882153 CFJ418P 10Amp Failed dimensional Fuse diameter measuring Closed PER 901153 Fuse criteria 0.001" too small requires final review and materi al disposition.

July 31 , 2014 PER 882164 CBT088Q 1 Amp Fuse Failed dimensional History search identified no Closed PER 899964 criteria materi al installed in safety related components. No changes required to procurement documents.

July 31 , 2014 PER 8821 41 ADM954A 35Amp Failed current clearing PER 932364 addressed 10 Closed PER 899965 (SON Fuse time CFR 21 considerations and Site) determined to NOT be reportable. History search identified no material installed in safety related components. No changes required to procurement documents.

July 31, 2014 PER 880803 CDC572Q 50Amp Failed voltage rating Expanded sample testing Closed Fuse per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

E 9of16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed)

July 31, 2014 PER 880819 BLA425C 1 Amp Fuse Failed current carrying Expanded sample testing Closed capacity and cracked per EPRI TR-017218, ferrules Revision 1, resulted in acceptance of the fuse lot.

Material with cracked ferrules dispositioned to be scrapped.

July 31, 2014 PER 882129 BLA414H 1.25 Amp Failed current clearing Expanded sample resulted Closed PER 898433 Fuse time in additional material failure. Material has been scrapped. Procurement documents have been cancelled and Item is desiQnated as obsolete.

July 31 , 2014 PER 900197 BYL598T 30Amp Failed dimensional Fuse diameter measuring Closed (BFN Site) Fuse criteria 0.001" too large requires final review and material disposition . Based on review and application of revised tolerance, the material is acceptable July 31 , 2014 PER 885235 BKY581W 1 Amp Fuse Failed current clearing Expanded sample resulted Closed PER 896391 time in additional material failure. Material not acceptable for plant use and scrapped. No changes identified for procurement documents.

July 31 , 2014 PER 895583 AEY065C 1.25Amp Failed current clearing History search identified no Closed Fuse time material installed in safety related components. No changes required to procurement documents.

July 31 , 2014 PER 882169 BHQ577Y 0.25 Amp Failed current clearing Expanded sample testing Closed Fuse time per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

July 31 , 2014 PER 882149 BRE028R 20Amp Failed current clearing Expanded sample testing Closed Fuse time per EPRI TR-017218, Revision 1. resulted in acceptance of the fuse lot.

July 31 , 2014 PER 882150 CET176J 1.6Amp Failed current clearing Expanded sample testing Closed Fuse time per EPRI TR-017218, Revision 1. resulted in acceptance of the fuse lot.

July 31, 2014 PER 882168 BBR516K 5 Amp Fuse Failed current carrying Expanded sample testing Closed capacity per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

E 10 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SRIPER CATID Item Failure Disposition Status Report Date Number Description Description (Open/

Closed\

July 31, 2014 PER 885242 CJD815L 60Amp Failed current carrying Expanded sample testing Closed PER 900219 Fuse capacity and per EPRl TR-017218, commercial failure Revision 1, resulted in acceptance of the fuse lot.

Remaining PER actions to review procurement requirements and dispositions failed material from a commercial perspective.

July 31 , 2014 PER 895584 CHQ955H 1100 Amp Failed current clearing History search identified no Closed Fuse time material installed in safety related components. PER 956198 identifies CGD testing and procurement documents acceptable.

July 31 , 2014 PER 885244 BKY793D 60Amp Failed current clearing Material not acceptable for Closed PER 896395 Fuse time plant use and scrapped.

No changes identified for procurement documents.

July 31 , 2014 PER 880809 BTI498Q 50Amp Failed voltage rating Expanded sample testing Closed Fuse per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

July 31, 2014 PER 888324 BEE283N 30Amp Failed current carrying Material not acceptable for Closed PER 912990 Fuse capacity plant use. History search identified no material installed in safety related components. No changes required to procurement documents.

July 31 , 2014 PER 899963 BYL598T 30Amp Failed current carrying PER 932364 addressed 1O Closed (SQN Fuse capacity and CFR 21 considerations and Site) dimensional criteria determined to NOT be reportable. History search identified no material installed in safety related components. PER 966136 for Procurement Engineering to enhance CGD criteria.

July 31 , 2014 PER 886874 CEP098J 30Amp Failed current carrying Expanded sample testing Closed Fuse capacity per EPRI TR-017218, Revision 1, resulted in acceptance of the fuse lot.

October 31 , PER 920903 ADM954A 35Amp Failed current carrying Material not acceptable for Closed 2014 (BFN Site) Fuses capacity plant use and scrapped.

No material installed in safetv-related applications.

October 31 , PER 920910 CME546X 2.25 Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use in safety related applications and scrapped.

No material installed in safety-related aoolications.

E 11 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report PREVIOUSLY IDENTIFIED TESTING FAIL URES Initial Sta tus SR/PER CATID Item Failure Disposition Status Report Date Num ber Des cription Description (Open/

Closed}

October 31 , PER 924650 CEN006Q 1.6Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use in safety related applications and scrapped.

No material installed in safety-related aoolications.

October 31, PER 924138 BLA422J 12Amp Failed current carrying History search identified no Closed 2014 Fuses capacity materi al installed in safety related components.

Re-test of inventory material prior to acceptance and release from Hold status as a conservative measure.

October 31 , PER 925152 CFN093V 7 Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use in safety related applications and scrapped.

No material installed in Safety Related aoolications.

October 31 , PER 918351 BLD150M 10amp Failed current carrying Passing material lots Closed 2014 fuses capacity accepted. Failed lots scrapped. Fuses installed in Safety Related applications evaluated as acceptable.

October 31 , PER 924148 CPA432M 3600 µF Incorrect dimensional Items re-inspected to Closed 2014 Capacitors criteria revised criteria. One of 10 Items failed and Scrapped.

All remaining items acceptable. Installed Safety Related applications acceptable.

October 31, PER 926791 BPQ794H 8Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use and recommended to be scrapped.

No material installed in Safety Related aoolications.

October 31 , PER 926998 CAA223F 6.25Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use and scrapped.

No material installed in Safety Related applications. Procurement documents in Cancelled status.

October 31 , PER 937329 BLD276K 8Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use in safety related applications and scrapped.

No material installed in Safety Related applications. Procurement documents acceptable.

E 12 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 20 15 Status Report PREVIOUSLY IDENTIFIED TESTING FAILURES Initial Status SR/PER CATID Item Failure Disposition Status Report Date Num ber Description Description (Open/

Clos ed}

October 31 , PER 940584 BAV418F 2.5Amp Failed current carrying Material not acceptable for Closed 2014 Fuses capacity plant use in safety related applications and recommended to be scrapped.

Issued material not installed in Safety Related aoolications.

October 31, PER 937330 CAA069M 4Amp Failed current carrying Material from fai led lot sent Closed 201 4 Fuses capacity for additional testing.

Material in passed lot found acceptable No material installed in Safety Related aoolications.

October 31 , PER 922302 CB0738P 0.10 µF Failed capacitance Material identified as failed. Open 2014 Capacitors criteria Remaining actions include review of laboratory report, disposition material and verify issue history.

October 31, PER 922301 AFM357G 10 amp fuse Failed capacitance Material identified as failed . Open 2014 criteria Remaining actions include review of laboratory report, disposition material and verify issue history.

October 31 , PER 937305 ACM855J 2Amp Failed capacitance No material installed in Open 2014 Fuses criteria safety-related applications.

Material identified as failed.

Remaining actions include review of laboratory report and disposition material.

October 31, PER 940682 BYE634G 25 Amp Failed capacitance No material installed in Open 2014 Fuses criteri a safety-related applications.

Material identified as failed.

Remaining actions include review of laboratory report and disposition material.

October 31 , PER 940658 BVN393M 15Amp Failed capacitance Material installed in safety- Open 2014 Fuses criteria related applications evaluated. Material identified as failed.

Remaining actions include review of laboratory report and disposition material.

E 13 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report RECENTLY IDENTIFIED ISSUES:

The following testing failures were recently identified and entered into the corrective action program:

Problem Evaluation Report 953283 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 40 amp fuses (CATID AEM751J) . The current clearing time acceptance criterion specifies that with a test circuit consisting of 200 amps (+10/-0%). fuse shall blow in no less than 10 seconds. Of one fuse tested against current clearing time acceptance criteria, one fuse destructively tested failed to meet the testing acceptance criteria by clearing early at 2.5 seconds. A review of previously issued inventory was performed, identifying fuses issued for safety-related applications from the failed material lot. Review of the installed location concluded that operability is maintained. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

Problem Evaluation Report 953270 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 2 amp fuses (CATID BBN835J). The current clearing time acceptance criterion specifies that with a test circuit consisting of 1O amps

(+10/-0%), fuse shall blow in no less than 8 seconds. Of four fuses tested against current clearing time acceptance criteria, one fuse destructively tested failed to meet the testing acceptance criteria by clearing at 7.65 seconds. A review of previously issued inventory was performed. identifying fuses issued for safety-related applications from the failed material lot.

Review of the installed locations concluded that operability is maintained and fuses are both functional and not degraded/non-conforming . This condition will be further evaluated , as described in the CGD Recovery Project Plan.

Problem Evaluation Report 959240 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 45 amp fuses (CATID BKY962G). The current clearing time acceptance criterion specifies that with a test circuit consisting of 225 amps (+10/-0%). fuse shall blow in no less than 10 seconds. Of 14 fuses tested against current clearing time acceptance criteria , one fuse destructively tested failed to meet the testing acceptance criteria by clearing at 0.27 seconds. A review of inventory was performed, identifying no fuses were issued for safety-related applications from the failed material lot.

Review by operations concluded that operability is not affected. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

Problem Evaluation Report 963444 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 60 amp fuse (CATID BFJ723R). The current clearing time acceptance criterion specifies that with a test circuit consisting of 300 amps (+1 0/-0%), fuse shall blow in no less than 10 seconds. Of one fuse tested against current clearing time acceptance criteria, one fuse destructively tested failed to meet the testing acceptance criteria by clearing at 9.25 seconds. A review of previously issued inventory was performed, identifying no fuses were issued for safety-related applications from the failed material lot. Review by operations concluded no operability concerns. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

Problem Evaluation Report 963436 was generated to identify and address failure of critical characteristic testing criteria for current carrying capacity of 4 amp fuses (CATID BVA249T).

E 14 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report The current carrying capacity test applies 4 amps (+ 10/-0%) until the fuse is thermally stable.

Temperature stabilization has occurred when no individual temperature rise reading of four consecutives readings taken at 5 minute intervals exceeds the average reading of these four readings by more than 2 degrees Celsius. An acceptable test shows the fuse is intact and no signs of breakdown or deterioration. Of 25 fuses initially tested for current carrying capacity, one fuse failed to meet the acceptance criteria by opening during testing. A review of previously issued inventory was performed , identifying no fuses were issued for safety-related applications from the failed material lot. Review by operations concluded no operability concerns. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

Problem Evaluation Report 956205 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 15 amp fuses (CATID BBJ158P). The current clearing time acceptance criterion specifies that with a test circuit consisting of 30 amps

(+10/-0%), fuse shall blow in no greater than 240 seconds. Of five fuses tested against current clearing time acceptance criteria , three fuses destructively tested failed to meet the testing acceptance criteria by clearing at 342.93, 242.15 and 252.97 seconds. A review of inventory was performed, identifying no fuses were issued for safety-related applications from the failed material lot. Review by operations concluded that operability is not affected. This item is closed. The condition was evaluated and determined not to be reportable.

Problem Evaluation Report 968055 was generated to identify and address failure of critical characteristic testing criteria for voltage rating and current clearing tests of 1600 amp (CATID CAE073A), 1200 amp (CATID CHG399Y), 2000 amp (CATID CGT041L) and 2500 amp (CATID CGT119J) high current fuses. The voltage rating acceptance criterion specifies applying 100%

rated voltage (600 VAC) for 15 minutes to the cleared (opened) fuse from the previous overload tests. The fuse successfully passes given no re-establishment of current or any indication of a tendency to re-strike. For CATI D's CAE073A, CHG399Y and CGT041 L, all but one cleared fuse experienced a restrike when rated voltage was applied. For CATID CGT119J, failure of critical characteristic testing criteria for current clearing time of 2500 amp fuses. The current clearing time acceptance criterion specifies that with a test circuit consisting of 3750 amps

(+10/-0%), fuse shall blow in no greater than 240 minutes. The single fuse failed to clear by 84 minutes, when the equipment was secured due to thermal overload. For these tests, lab conditions, equipment limitations and restraints, the observed results were predicted outcomes; therefore, this condition will be further evaluated, as described in the CGD Recovery Project Plan to determine appropriate testing or procurement strategy.

Problem Evaluation Report 965252 was generated to identify and address failure of critical characteristic testing criteria for voltage rating of 1 amp (CATID CQH798A) and 450 amp (CATID CJN746Y) high voltage fuses. The voltage rating acceptance criterion specifies applying 100% rated voltage (5500 VAC) for 15 minutes to the cleared (opened) fuse from the previous overload tests. The fuses successfully pass given no re-establishment of current or any indication of a tendency to re-strike. All cleared fuses experienced a restrike when rated voltage was applied. For these tests, lab conditions, equipment limitations and restraints, the observed results were predicted outcomes; therefore, this condition will be further evaluated, as described in the CGD Recovery Project Plan to determine appropriate testing or procurement strategy.

E 15 of 16 CNL-15-018

ENCLOSURE Tennessee Valley Authority (TVA) Nuclear Power Group Commercial Grade Dedication Recovery Project - January 2015 Status Report Problem Evaluation Report 963720 was generated to identify and address failure of critical characteristic testing criteria for dimensions and configuration of a fitting , tubing cap nut (CATID AXM024C) . The nuts failed the Hex Height dimension (0.435" to 0.445") by measuring larger than the tolerance at 0.466", 0.467", 0.468" and 0.471". All four nuts failed the configuration verification by exhibiting a sharp edge trapezoidal cross section vs. a domed cap appearance.

A review of previously issued inventory was performed, identifying tubing cap nuts issued for safety-related applications from the failed material lot. Review of the installed location concluded that operability is maintained. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

Problem Evaluation Report 965852 was generated to identify and address failure of critical characteristic testing criteria for current clearing time of 700 amp high current fuse (CATID CQM152W). The current clearing time acceptance criterion specifies that with a test circuit consisting of 1050 amps (+10/-0%), fuse shall blow in no greater than 240 minutes. Of one fuse tested against current clearing time acceptance criteria, one fuse destructively tested failed to meet the testing acceptance criteria by failing to clear in 270 minutes. As a result of the fuse not clearing, the voltage rating test could not be performed. A review of inventory was performed, identifying no fuses were issued for safety-related applications from the failed material lot.

Review by operations concluded that operability is not affected. This condition will be further evaluated, as described in the CGD Recovery Project Plan.

E 16 of 16 CNL-15-018