SDM B 3.1.1 McGuire Units 1 and 2 B 3.1.1-1 Revision No. 115 B 3.1 REACTIVITY CONTROL SYSTEMS B 3.1.1 SHUTDOWN MARGIN (SDM)

BASES BACKGROUND According to GDC 26 (Ref. 1), the reactivity control systems must be redundant and capable of holding the reactor core subcritical when shut down under cold conditions. Maintenance of the SDM ensures that postulated reactivity events will not damage the fuel.

SDM requirements provide sufficient reactivity margin to ensure that acceptable fuel design limits will not be exceeded for normal shutdown and anticipated operational occurrences (AOOs). As such, the SDM defines the degree of subcriticality that would be obtained immediately following the insertion or trip of all shutdown and control rods, assuming that the single rod cluster control assembly of highest reactivity worth is fully withdrawn. However, with all rod cluster control assemblies verified fully inserted by two independent means, it is not necessary to account for a stuck rod cluster control assembly in the shutdown margin calculation.

The system design requires that two independent reactivity control systems be provided, and that one of these systems be capable of maintaining the core subcritical under cold conditions. These requirements are provided by the use of movable control assemblies and soluble boric acid in the Reactor Coolant System (RCS). The Rod Control System can compensate for the reactivity effects of the fuel and water temperature changes accompanying power level changes over the range from full load to no load. In addition, the Rod Control System, together with the boration system, provides the SDM during power operation and is capable of making the core subcritical rapidly enough to prevent exceeding acceptable fuel damage limits, assuming that the rod of highest reactivity worth remains fully withdrawn. The soluble boron system can compensate for fuel depletion during operation and all xenon burnout reactivity changes and maintain the reactor subcritical under cold conditions.

During power operation, SDM control is ensured by operating with the shutdown banks fully withdrawn and the control banks within the limits of LCO 3.1.6, "Control Bank Insertion Limits." When the unit is in the shutdown and refueling modes, the SDM requirements are met by means of adjustments to the RCS boron concentration.

SDM B 3.1.1 BASES McGuire Units 1 and 2 B 3.1.1-2 Revision No. 115 APPLICABLE The minimum required SDM is assumed as an initial condition in safety SAFETY ANALYSES analyses. The safety analysis (Ref. 2) establishes an SDM that ensures specified acceptable fuel design limits are not exceeded for normal operation and AOOs, with the assumption of the highest worth rod stuck out on a reactor trip.

The acceptance criteria for the SDM requirements are that specified acceptable fuel design limits are maintained. This is done by ensuring that:

a.

The reactor can eventually be made subcritical from all operating conditions, transients, and Design Basis Events;

b.

The reactivity transients associated with postulated accident conditions are controllable within acceptable limits (departure from nucleate boiling ratio (DNBR), fuel centerline temperature limits for AOOs, and 280 cal/gm energy deposition for the rod ejection accident); and

c.

The reactor will be maintained sufficiently subcritical to preclude inadvertent criticality in the shutdown condition.

One limiting accident for the SDM requirements is based on a main steam line break (MSLB) in Mode 2, as described in the accident analysis (Ref. 2). The increased steam flow resulting from a pipe break in the main steam system causes an increased energy removal from the affected steam generator (SG), and consequently the RCS. This results in a reduction of the reactor coolant temperature. The resultant coolant shrinkage causes a reduction in pressure. In the presence of a negative moderator temperature coefficient, this cooldown causes an increase in core reactivity. As RCS temperature decreases, the severity of an MSLB decreases. The most limiting MSLB, with respect to potential fuel damage before a reactor trip occurs, is a break of a main steam line upstream of the Main Steam Isolation Valve initiated at the end of core life. The positive reactivity addition from the moderator temperature decrease will terminate when the affected SG boils dry, thus terminating RCS heat removal and cooldown. Following the MSLB, a post-trip return-to-power may occur; however, no fuel damage occurs as a result of the post-trip return-to-power, and THERMAL POWER does not violate the Safety Limit (SL) requirement of SL 2.1.1.

A potentially more limiting MSLB accident could occur for a steam line break outside containment when in Mode 3 with the low pressurizer pressure signal for safety injection actuation blocked. In this scenario, feedwater would not automatically isolate and the peak heat fluxes associated with the return-to-power may increase to values significantly

SDM B 3.1.1 BASES McGuire Units 1 and 2 B 3.1.1-3 Revision No. 115 APPLICABLE SAFETY ANALYSES (continued) greater than those in the accident analysis (Ref. 2). Therefore, when safety injection is blocked, administrative controls on boron concentration are required to prevent a return-to-power following a steam line break.

In addition to the limiting MSLB transient, the SDM requirement must also protect against:

a.

Inadvertent boron dilution;

b.

An uncontrolled rod withdrawal from subcritical or low power condition; and

c.

Rod ejection.

Each of these events is discussed below.

In the boron dilution analysis, the required SDM defines the reactivity difference between an initial subcritical boron concentration and the corresponding critical boron concentration. These values, in conjunction with the configuration of the RCS and the assumed dilution flow rate, directly affect the results of the analysis. This event is most limiting at the beginning of core life, when critical boron concentrations are highest.

Depending on the system initial conditions and reactivity insertion rate, the uncontrolled rod withdrawal transient is terminated by either a high power level trip or a high pressurizer pressure trip. In all cases, power level, RCS pressure, linear heat rate, and the DNBR do not exceed allowable limits.

The ejection of a control rod rapidly adds reactivity to the reactor core, causing both the core power level and heat flux to increase with corresponding increases in reactor coolant temperatures and pressure.

The ejection of a rod also produces a time dependent redistribution of core power. SDM satisfies Criterion 2 of 10 CFR 50.36 (Ref. 3). Even though it is not directly observed from the control room, SDM is considered an initial condition process variable because it is periodically monitored to ensure that the unit is operating within the bounds of accident analysis assumptions.

Transients which are made less severe by the rapid insertion of control rod negative reactivity are also affected by the magnitude of the SDM limit. This is because the safety analyses assume a change in the rate of insertion of this negative reactivity when the SDM limit is reached. While the SDM is less than the limit value, the negative reactivity from the

SDM B 3.1.1 BASES McGuire Units 1 and 2 B 3.1.1-4 Revision No. 115 APPLICABLE SAFETY ANALYSES (continued) control rods is assumed to be inserted as quickly as the rod worth vs.

time curves shown in Reference 5. When the SDM limit value is reached, the rate of negative reactivity insertion is decreased so that it is only fast enough to compensate for any positive reactivity insertion, e.g., from the cooling of the fuel and moderator (which normally have negative temperature coefficients). This methodology is conservative in that it does not take credit in the safety analyses, even temporarily, for a SDM greater than the limit value.

LCO SDM is a core design condition that can be ensured during operation through control rod positioning (control and shutdown banks) and through the soluble boron concentration.

The MSLB (Ref. 2) and the boron dilution (Ref. 4) accidents are the most limiting analyses that establish the SDM value of the LCO. For MSLB accidents, if the LCO is violated, there is a potential to exceed the DNBR limit and to exceed 10 CFR 100, "Reactor Site Criteria," limits (Ref. 5).

For the boron dilution accident, if the LCO is violated, the minimum required time assumed for operator action to terminate dilution may no longer be applicable.

APPLICABILITY In MODE 2 with keff < 1.0 and in MODES 3, 4, and 5, the SDM requirements are applicable to provide sufficient negative reactivity to meet the assumptions of the safety analyses discussed above. In MODE 6, the shutdown reactivity requirements are given in LCO 3.9.1, "Boron Concentration." In MODES 1 and 2 with keff 1.0, SDM is ensured by complying with LCO 3.1.5, "Shutdown Bank Insertion Limits,"

and LCO 3.1.6.

ACTIONS A.1 If the SDM requirements are not met, boration must be initiated promptly.

A Completion Time of 15 minutes is adequate for an operator to correctly align and start the required systems and components. It is assumed that boration will be continued until the SDM requirements are met.

In the determination of the required combination of boration flow rate and boron concentration, there is no unique requirement that must be satisfied. Since it is imperative to raise the boron concentration of the RCS as soon as possible, the boron concentration should be a highly concentrated solution, such as that normally found in the boric acid

SDM B 3.1.1 BASES McGuire Units 1 and 2 B 3.1.1-5 Revision No. 115 ACTIONS (continued) storage tank, or the refueling water storage tank. The operator should borate with the best source available for the plant conditions.

In determining the boration flow rate, the time in core life must be considered. For instance, the most difficult time in core life to increase the RCS boron concentration is at the beginning of cycle when the boron concentration may approach or exceed 2000 ppm. Using its normal makeup path, the Chemical and Volume Control System (CVCS) is capable of inserting negative reactivity at a rate of approximately 30 pcm/min when the RCS boron concentration is 1000 ppm and approximately 35 pcm/min when the RCS boron concentration is 100 ppm. If the emergency boration path is used, the CVCS is capable of inserting negative reactivity at the rate of 65 pcm/min when the RCS boron concentration is 1000 ppm and 75 pcm/min when the RCS boron concentration is 100 ppm. Therefore, if SDM had to be increased by 1%

k/k or 1000 pcm, normal makeup path at 1000 ppm could restore SDM in approximately 33 minutes. At 100 ppm, SDM could be restored in approximately 29 minutes. In the emergency boration mode at 1000 ppm, the 1% k/k could be restored in approximately 15 minutes. With RCS boron concentration at 100 ppm, SDM could be increased by 1000 pcm in approximately 13 minutes using emergency boration. These boration parameters represent typical values and are provided for the purpose of offering a specific example.

SURVEILLANCE SR 3.1.1.1 REQUIREMENTS In MODES 1 and 2 with keff 1.0, SDM is verified by observing that the requirements of LCO 3.1.5 and LCO 3.1.6 are met. In the event that a rod is known to be untrippable, however, SDM verification must account for the worth of the untrippable rod as well as another rod of maximum worth.

In MODE 2 with keff < 1.0 and MODES 3, 4, and 5, SDM is verified by performing a reactivity balance calculation, considering the listed reactivity effects:

a.

RCS boron concentration;

b.

Control bank position;

c.

RCS average temperature;

d.

Fuel burnup based on gross thermal energy generation;

e.

Xenon concentration;

SDM B 3.1.1 BASES McGuire Units 1 and 2 B 3.1.1-6 Revision No. 115 SURVEILLANCE REQUIREMENTS (continued)

f.

Samarium concentration; and

g.

Isothermal temperature coefficient (ITC).

Using the ITC accounts for Doppler reactivity in this calculation because the reactor is subcritical, and the fuel temperature will be changing at the same rate as the RCS.

The Surveillance Frequency is based on operating experience, equipment reliability, and plant risk and is controlled under the Surveillance Frequency Control Program.

REFERENCES

1.

10 CFR 50, Appendix A, GDC 26.

2.

UFSAR, Section 15.1.5.

3.

10 CFR 50.36, Technical Specifications, (c)(2)(ii).

4.

UFSAR, Section 15.4.6.

5.

10 CFR 100.