Text

File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_1.mxd; Date: 06/26/2014; User: Serkan Bozkurt, LCIExtent of Plate 1 P a c i f i c O c e a n!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!J J J J J J J J J J J J QsQsQsQsQsQsQsQsQsQsQs QsQsQs Tmo TmoTmo TmoTmoTmo TmoTmoTmo Tmo TmoTmoTmoTmoTmo TmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmo TmoTmoTmoTmo Ks KsKs KsKsKs Ks KsKsKsKsKsKsKs KsKsKs KsKsKsKs KsKsKsKsQswQswQswQswQswQswQswQswQswQswQsw QswKJfKJf KJfKJfKJfKJf KJfKJfKJfKJfKJfKJfKJfKJfmKJfmKJfmKJfm KJfm KJfmKJfmKJfmKJfmKJfm KJfmKJfmKJfm KJfm KJfmKJfm KJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfm KJfm KJfmKJfmKJfmKJfm KJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmafafaf afQuQuQcsQcsQcsQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmTmmTmmTmmTmmTmmTmmTmm TmmTmmTmmTmmTmm Tmm TmmTmmTmpmTmpm TmpmTmpm Tmpm TmpmTmpm TmpmTmpm Tmpm TmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpe TmpeTmpe Tmpe TmpeTmpe TmpeTmpeTmpeTmpe TmpeKJfoQalQalQalQalQalQalQalQalQalQal QalQalQalQalQalQalQalQal QalQal QalQal QalQalQalQalQalQal QalQalQalQalQalQalQalQalTppg TppgTppg TppgTppgTppg TppsTppsTpps TppsTppsTppsTppsTppsTppb TppbTppb TppbTppbTppb TppbTppbTovTov TovTovTovTov TovTov TovTovTovTovTov TovTov TovTovTovTovTov Tov Tov TmodTmodTmodTmodTmodTmod TmodTmodTmodchchchch ch chchchchchchQtQtQtQt QtQt QtQtQtQt s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s QcQcQcQcQcQcQcTmrTmrTmr TmrTmrTmrTmr TmrTmrTmr TmrTmrTmrQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoaQoa QoaQoa QafQafQafQafQafQafQafQafQafQafQafgwgwgw gwgwgwgwgwgwgwmvmvmvKJfmvKJfmvKJfmv KJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmv KJfmvKJfmvKJfmvKJfmvKJfmvKJfmv QeQeQeQeQeQeQeQe QeQeQeQeQeQeQeQeQeQeQe KJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfg KJfgKJfgKJfgKJfgKJfgKJfgTomTomTomTom TomTomTom Tom TomTom Tom Tom TomTom TomTomTom TomTomTomTomTomTocf Qls QlsQlsQls QlsQls Qls Qls QlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQls QlsQls Qls Qls QlsQlsQlsQlsQls QlsQlsQls Qls QlsQlsQls QlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQlsQls QlsQlsQlsQlsQlsQls Qls QlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQls QlsQls QlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQls QlsQlsQlsQlsQlsQlsQlsQlsQlsQls QlsQlsQls QlsQlsQlsQlsQlsQls chch smvmvTomTom s sgwch Tomch bsmvQal Qls ch Qls gwchch Qls Qls s mvmvschbs bsch QalQls ch ch mv sgw QlsbschTom ch Qalch KJfmKJfmgwsh chgw s ch gwch s KJfmvmv chch smv s sch s sch s chch Qls ch bsmv KJfchbsQal Qls Qal TovQls KJmf mv Qalch ch Qls gw bsQls Tmrmvchmv chsc cgchgwtovgw cgmv Qls ch Qlsch mvmv schchchch mvgwgw ch sch gw KJfmQls Qal s chmv s mv Qls ch sQalQalQalQs Qu QlsQls TppsQalQls Qls Tmo Qls QswQs Qls Tmo Qaf QlsTmpm chmvmvKjfmmv s Tom s mvgw ch KJfmQlsgw s sTmpm TmrQlsQlsQlsQalKJfgTmpeTmpe ch shmvch sQlsQls Tov TmrTovmvchQafTmrQalQls Qls Qm Qls Qm mvTmoQlsTmrch QlsQlsgwTppgTmpeQtQtTmmKsTmm mvgwch s s sQesTmodTmr TovTmrQsshTovKJfm^

_MorroBayEsteroBaySan LuisObispo BayEdna fault zone DCPP L u i s B a y f a u l t z o n eShoreline fault zoneMorroRockPoint Buchon faultPismo synclineLos Osos fault zoneSanPismo syncline204 W204 N112-140 C B F E D AC'BF'E'D'AA'B'AvilaBeachBaywood-LosOsosGoldtreeLos OsosMorroBayPismoBeachPort SanLuisSan LuisObispoLagunaLakeLos Osos fault zoneSan Miguelito fault zoneShoreline fault zoneLos Osos fault zoneEdna fault zone400060008000100001400016000180002000022000 02000600080001000012000160002400026000280003000032000204 04000 0200040006000800010000120001400016000180002000022000240002600028000 02000400060008000100001200014000160001800020000220002400026000280003000032000340003600038000PointBuchonPointSan Luis 02000400060007571 020008000100001200014000160005445334250492856444554363739751922546857473225802421373129452620411915545268447689504051724416324845426444296714 7361831485237523852301023541930212245474542576231454568505556565047293247 939361458546464776660786560762731484351574369635352356551615250757462517361373835571738664055555145444757505553374063306423424430456036374636674532503231355648305529454625464145323018188441424844406536444434212010155115773846522434352820201718181723473614667066805643475224644830434036705418283429415255483876434847604179244057 0200040006000800010000120001000012000140001600018000 0200040006000800010000120008085 020004000600053 7 984 02000400060001000012000 0200040006000 020004000600080001000012000140008080707475856580707080656020272048603880335565405535723035423557304070554545504525643017354836352122255356202040362740 85550154549258547353540462447857650263045555046702335503040104542643187232650702036305025427585301587854035456510401583253027 745706030153710255210405055502550704550436220505245504545603560554567805545404574254070604065524060407538555045854047354530395051224070502935505055333045376560405139263730632330424132375050455840322954633047557031454040488065652544455046404140656850486336406045477848303147455035604860456547444550544742553950347053505045583265456035704560564556654070565251554065506548254555707542504648614553456555304835504850457546454530364135404531353555556050303065444550604831453525665025605542675565501032655550356550623545756025752545405534454970455065356546355325343555301565304560453565406060453260408020285072455035326576457548363542305058406545555130 86550705530326865358560438535604840 51152403580403548604730724255351035284052 93018454015263730125040455040305050504010255835103032654555756560354840603040455022255580231526708060202035254540254530403015403045105030354225623037201635104015603545224820705010254480 85015357025755045152575242540495236243229457235255430506025244025346829455520 53260606535207035204555456225653025406022455525405535322536306525351555252521351230474535203510185025458080303022322535501240203125201520457015654732152125251835505545252530502029306040353538504035674526507085605025208048603065454053364745557072352158366020352530656080608080857270556080807065604085 0200040006000800010000120001400016000180002000022000Old See Canyon 1Maino-Gonzales 1Pecho 1Spooner 1BassiCoreHole 1Honolulu-Tidewater 1Montadoro 1Townsend-Gunter 1Townsend-Peterson 1Sousa 1CCWPechoS&T newLOCSD -SB deepCCW -SB#1LOCSD -Ferrell #2LOCSD -10th newLOCSD -PalisadesUSGS -Palisades113207117114138-149118121150105103-104141-142 S141-142 N-120°40'-120°40'-120°45'-120°45'-120°50'-120°50'-120°55'-120°55'35°20'35°20'35°15'35°15'35°10'35°10'Geologic Map SourcesComposite DEM, version 7 (DCPP Geodatabase, 2013)Base Image:- Cleath & Associates, 2005, Sea Water Intrusion Assessment and Lower Aquifer Source Investigation of the Los Osos Valley Ground Water Basin, San Luis Obispo County, California, unpublished consulting report prepared for the Los Osos Community Services District, October 2005. - Fugro William Lettis & Associates, 2009, Unpublished field maps from coastline mapping at Diablo Canyon Power Plant site, scale 1:2400 to 1:1200.- Fugro William Lettis & Associates, 2010, Unpublished field maps from coastline mapping, Rattlesnake Creek to the Diablo Canyon Power Plant, scales include 1:1200, 1:2400, and 1:4800.

- Fugro William Lettis & Associates, 2011, Transmittal and Documentation of GIS Shape Files of Landslides, Landslide Susceptibility, and Liquefaction Susceptibility for HAZUS Input to Diablo Canyon Power Plant Evacuation Plan, Letter Report and Data CD, dated February 18, 2011.- Hall, C.A., 1973a, Geologic Map of the Morro Bay South and Port San Luis Quadrangles, California, U.S. Geological Survey Misc. Field Studies Map FM-511, scale 1:24,000.

- Hall, C.A., 1973b, Geology of the Arroyo Grande 15' Quadrangle, California, California Division of Mines and Geology Map Sheet 24, scale 1:48,000.- Hall, C.A., and Prior, S.W., 1975, Geologic Map of the Cayucos-San Luis Obispo Region, San Luis Obispo County, California, U.S. Geological Survey Misc. Field Studies Map MF-686 (two sheets), scale 1:24,000.- Hall, C.A. Jr., Ernst, W.G., Prior, S.W., and Wiese, J.W., 1979, Geologic Map of the San Luis Obispo-San Simeon Region, California, U.S. Geological Survey Misc. Investigation Series Map I-1097 (three sheets), scale 1:48,000.

- Hanson, K.L., Wesling, J.R., Lettis, W.R., Kelson, K.I., and Mezger, L., 1994. Correlation, ages, and uplift rates of Quaternary marine terraces, south-central California, in Alterman, I.B., McMullen, R.B., Cluff, L.S., and Slemmons, D.B. (Editors), Seismotectonics of the Central California Coast Range: Geological Society of America Special Paper 292. p. 45-72 and Plate Z.- Jahns, R.H., and others, 1973, Geology of the Diablo Canyon Power Plant Site, San Luis Obispo County, California, unpublished(?) map for Pacific Gas & Electric Company, iterations of map used in PG&E (1974) FSAR for Units 1 and 2, approximate scale 1:500.- Lettis, W.R., and Hall, N.T., 1994, Los Osos fault zone, San Luis Obispo County, California, in Alterman, I.B., McMullen, R.B., Cluff, L.S., and Slemmons, D.B., eds., Seismotectonics of the Central California Coast Ranges, Geol. Soc. Am. Special Paper 292, p.73-102 and Plate 5.

- Pacific Gas and Electric Company (PG&E), 1974, Units 1 and 2 Diablo Canyon Power Plant, Final Safety Analysis Report, Update 20, U.S. Nuclear Regulatory Commission Docket Nos. 50-275 and 50-323, Figures 2.5-5, 2.5-6, 2.5-8, and 2.5-12. Also includes: Earth Science Associates, 1974, Geologic Map of the Morro Bay South and Point San Luis Quadrangles, San Luis Obispo County, California: and Adjacent Offshore Area, Plate VIII, Appendix 2.5D, scale 1:24,000.

- Pacific Gas and Electric Company (PG&E), 1990, Response to Question GSG Q16, Diablo Canyon Long Term Seismic Program, Diablo Canyon Power Plant, U.S. Nuclear Regulatory Commission Docket No. 50-275 and No. 50-323, Plate GSG Q16-1.- Pacific Gas and Electric Company (PG&E), 2004, Final Safety Analysis Report of the Diablo Canyon Independent Spent Fuel Storage Installation, U.S. Nuclear Regulatory Commission Docket No. 72-26, Figures 2-6.6, 2.6-7, and 2.6-8.

- Pacific Gas and Electric Company (PG&E), 2011, Report on the Analysis of the Shoreline Fault Zone, Central Coastal California, Report to the U.S. Nuclear Regulatory Commission, January 2011. http://www.pge.com/myhome/edusafety/systemworks/dcpp/shorelinereport/.- Pacific Gas and Electric Company (PG&E), 2012, DCPP 3D/2D Seismic-Reflection Investigation of Structures Associated with the Northern Shoreline Seismicity Sublineament of the Point Buchon Region, PG&E Geosciences Department Technical Report Number GEO.DCPP.TR.12.01, December 2012.- Pacific Gas and Electric Company (PG&E), 2014, Interpretation of Seismic Reflection Data, Point Buchon to San Simeon Point, PG&E Geosciences Department Technical Report Number GEO.DCPP.TR.14.05, expected June 2014.- Wiegers, M.O., 2009, Geologic Map of the Morro Bay South 7.5' Quadrangle, San Luis Obispo County, California: A Digital Database, Version 1.0, scale 1:24,000.

- Wiegers, M.O., 2010, Geologic Map of the San Luis Obispo 7.5' Quadrangle, San Luis Obispo County, California: A Digital Database, Version 1.0, scale 1:24,000.- William Lettis & Associates, 1996, Unpublished geology compilation map produced for the DCPP Dry Cask Facility, Geologic/Geotechnical Siting Study, Plate 1 dated February 1996, scale 1:2400.- William Lettis & Associates, 1998, Unpublished geologic map for the PG&E Diablo Canyon Power Plant Dry Cask Storage Facility Siting Study, prepared in April and May 1998 with revisions in May 1998 and February 2001, scale 1:2400.Extent ofPlate 2µMap Scale:1:32,000WGS 84 / UTM Zone 10NMap Projection:

0 1 2mi.0 2 4kmPLATE 1:Geologic Map of theIrish Hills and Adjacent AreaONSHORE SEISMIC INTERPRETATION PROJECTMontana de OroState ParkPacific Gas and Electric Company File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_6_Line_141_142_Vibe_North_South.mxd; Date: 06/26/2014; User: Jereme Chandler, LCI

!!!!!!!!!!!!!!!141-142 S141-142 N75334250492856444554363739751922546857473225802421373129452620411915545268447689504051724462314545685055656076273148435157436963535235655161525075373835571738664055555145444757505553374063306423424430456036374636313556483055293018846680564347522464483043403670541828342941554860794057808553 970847570272055405535723035423040363030878345435045674045254050404740355037605844656042704552555053456530504850454645404560504855505565655550355062756045557045506553605565456060453250404520504550352065767535425058405551 865705532686535856043854840 511522240806047723510284052 930351840152637125040455040405025351032651640605023152660202515104215372015222010258035754515703646453245506062254730453035124070556085 020004000600080001000012000 02000400060008000100001200014000Honolulu-Tidewater 1TmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoKsKsKsKsafafQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQmQmQmQmQmQmTmmTmmTmmTmmTmmTmpmTmpmTmpmTmpmTmpeTmpeTmpeTmpeTmpeQalQalQalQalQalQalQalQalQalQalQalQalQalQalKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmTovTovTovTovTovTovTovTovTmodTmodTmodTmodTmodchchchchch s s s s s s s s s s s s s s s s s s s s s sQcQcQcQcQcQcTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrQoaQoaQoaQoaQoaQoaQoaQafKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvQeKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgQalQe-120°48'-120°48'-120°50'-120°46'-120°44'35°18'35°11'-120°46'-120°44'35°18'35°16'35°16'35°14'35°14'35°11'(a) Geologic Strip Map(b) Vibroseis Line 141-142 North and South Seismic Reflection Profile

^_DCPPLocation Map1:24,000Scale: 02,0004,0006,000ft 01,0002,000 mµNotes: - 2011 3D Arb straight south 141-142 IEEE uninterpreted 05.08.2014 and 2011 3D Arb straight north 141-142 IEEE uninterpreted 05.08.2014.

- See Figures 5-9 and 5-10 for an uninterpreted image of the seismic reflection line.

- Horizontal offsets are shown along a topographic profile above the seismic line.- Horizons are mapped as solid where confident, dashed where uncertain, and queried where poorly constrained.EXPLANATIONFault: solid where well located,dashed where approximately locatedTop of Monterey FormationTop of Obispo FormationTop of Mesozoic basementTmmTmoKJfHorizontal distance alongseismic line, 2,000 ft incrementPLATE 6(a) Geologic Strip Map and (b) VibroseisLine 141-142 North and SouthSeismic Reflection Profile2011 ONSIPPacific Gas and Electric CompanyArrows marking offset ortruncated reflectors File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_5_Line_112_140_AWD.mxd; Date: 06/26/2014; User: Jereme Chandler, LCIPort SanLuisPointSan Luis 71 56 56 50 47 29 32 47 9 39 36 14 58 54 64 64 77 66 60 78 31 48 43 51 57 43 69 63 53 52 35 65 51 61 52 50 75 74 62 51 73 61 55 55 51 45 44 47 57 50 55 53 37 40 63 30 64 23 44 45 60 36 67 45 32 50 32 31 35 56 48 30 55 29 30 18 18 85 80 74 85 65 80 70 85 45 45 50 45 25 64 55 40 36 27 50 15 49 25 70 20 46 24 85 55 50 70 23 10 45 64 87 23 50 42 15 40 35 45 65 10 40 30 7 70 60 15 25 52 40 10 40 50 55 25 50 45 50 62 45 40 45 45 60 35 55 45 40 70 40 52 40 55 40 35 45 55 65 40 51 30 50 40 47 55 80 65 75 44 45 50 40 65 50 45 78 46 30 50 60 45 45 50 50 70 50 60 40 70 52 40 50 65 70 50 45 55 50 50 45 75 50 40 45 55 30 45 50 60 48 55 50 25 60 42 55 65 55 65 50 62 45 25 45 34 45 70 45 35 34 60 55 30 45 40 60 45 28 45 50 35 32 65 75 42 30 50 40 8 65 32 85 511 52 22 72 35 10 40 9 30 35 40 15 26 12 40 40 50 32 65 40 60 50 15 80 72 70Honolulu-Tidewater 1QalQsQsQsQsQsQsQsQsQsTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoKsKsKsKsKsKsKsKsKsKsKsKsKsQswQswKJfKJfKJfKJfKJfQuQuQuQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQmQmQmQmQmQmQmQmTmmTmmTmmTmmTmmTmpmTmpmTmpeTmpeKJfoQalQalQalQalQalQalQalQalQalQalQalQalQalQalQalKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmTppgTppgTppgTppgTppgTppsTppsTppsTppsTppsTppsTppsTppsTppbTppbTppbTppbTppbTppbTovTovTovQt s s s sTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrKJfg 0200040006000800010000120001400016000180002000022000240002600028000-120°48'-120°46'-120°46'-120°44'35°14'35°14'35°11'35°11'35°10'35°10'(a) Geologic Strip Map(b) AWD Line 112-140 Seismic Reflection Profile

^_DCPPLocation Map1:24,000Scale: 02,0004,0006,000ft 01,0002,000 mµMap projection and scale: WGS 84 / UTM Zone 10N,1:24,000EXPLANATIONFault: solid where well located,dashed where approximately locatedHorizontal distance alongseismic line, 2,000 ft incrementTop of Monterey FormationTop of Obispo FormationTop of Mesozoic basementTmmTmoKJfNotes:- Preferred Formation Picks Explanation (Geologic Mapping Project Report, Appendix E)

- Tmpm = Miguelito Member of the Pismo Formation

- Tmm = Monterey Formation

- Tmo = Obispo Formation- Tmr = Rincon Formation - Line QA_bpfagc_dwf 112-140 AWD fbm psdm 1 mix depth notvfagc ieee.

- See Figure 5-7 for an uninterpreted image of the seismic reflection line.

- Horizontal offsets are shown along a topographic profile above the seismic line.

- Horizons are mapped as solid where confident, dashed where uncertain, and queried where poorly constrained.PLATE 5(a) Geologic Strip Map and (b) AWDLine 112-140 Seismic Reflection Profile112-140Base of Cretaceous Sandstone(poorly constrained)2011 ONSIPPacific Gas and Electric CompanyArrows marking offset ortruncated reflectors File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_4_Line_204_Vibe_West.mxd; Date: 06/26/2014; User: Jereme Chandler, LCI204PointBuchon1831485237523852301023541930456037463645462546414532414248444065364444342120101551157738465224343528202017181817234736144847 7853535403548304255352840605218455037483012504550403054505050401050255835103032654555754560163548304045252225558023268060205020357025354540652545304030403045105030354225623037352016351040156035452248705010254420 85015357025457550302575245025404952362432297235255430502524404525346829455520 53260606535207035204555452565302540602245552540553532253630652540352515552530252135123060453520243510185025808030223225502031252015204515654732152125251835504525253050202930706040353538505040356745265070856050252080486030654540Maino-Gonzales 1Pecho 1Spooner 1Montadoro 1QsTmoTmoTmoTmoTmoTmoTmoTmoTmoQswQswQswQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQmQmQmQmQmQmQmQmTmmTmmTmmTmmTmmTmmTmmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpeQalQalQalQalQalQalQalQalQalQalQalQalQalQalQalQalKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmTovTovTovTovTovTovQtQt s s s s s s s s s s s sTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvQeQeQeQeQeQeQeQeQeQeKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfg 0200040006000800010000120001400016000180002000022000-120°48'-120°48'-120°50'-120°50'-120°52'-120°52'-120°54'-120°54'35°18'35°16'35°16'(a) Geologic Strip Map(b) Vibe Line 204 West Seismic Reflection Profile

^_DCPPLocation Map1:24,000Scale: 02,0004,0006,000ft 01,0002,000 mµMap projection and scale: WGS 84 / UTM Zone 10N,1:24,000Notes: - Trimmed_204_west_2D_beam_50K_vibeonly_

poly_sl_stackagc_IEEE_uninterpMay13.

- See Figure 5-5 for an uninterpreted image of the seismic reflection line.- Horizontal offsets are shown along a topographic profile above the seismic line.

- Horizons are mapped as solid where confident, dashed where uncertain, and queried where poorly constrained.EXPLANATIONFault: solid where well located,dashed where approximately locatedTop of Monterey FormationTop of Obispo FormationTop of Rincon FormationTop of Mesozoic basementTmmTmoTmrKJfHorizontal distance alongseismic line, 2,000 ft increment2011 ONSIPPacific Gas and Electric CompanyPLATE 4(a) Geologic Strip Map and (b) Vibe Line204 West Seismic Reflection ProfileArrows marking offset ortruncated reflectors File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_3_Line_204_AWD.mxd; Date: 06/26/2014; User: Jereme Chandler, LCI204PointBuchon48523752523037463645462546414532414248444065364444342120101551157738465224343528202017181817234736484724 785303054505058353065455575456016354830404525222555802326806020502035702535454065254530403015403045105030354225623037352016351040156035452248705010254420 8501535702545755030152575245025404952362432297235255430502524404525346829455520 53260606535207035204555452565302540602245552540553532253630652540352515552530252135123060453520243510185025808030223225502031252015204515654732152125251835504525253050202930706040353538505040356745265070856050252080486030654540Maino-Gonzales 1Pecho 1Montadoro 1QsTmoTmoTmoTmoTmoTmoTmoTmoQswQswQlsQlsQlsQlsQlsQlsQlsQlsQlsQlsQmQmQmQmQmQmQmTmmTmmTmmTmmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpeTmpeQalQalQalQalQalQalQalQalQalQalQalQalQalQalQalKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmKJfmTovTovTovTovTovTovQtQt s s s s s s s s s s s s s sTmrTmrTmrTmrTmrTmrTmrTmrTmrTmrKJfmvKJfmvKJfmvKJfmvKJfmvKJfmvQeQeQeQeQeQeQeQeQeQeKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfgKJfg 0200040006000800010000120001400016000180002000022000-120°48'-120°48'-120°50'-120°50'-120°52'-120°52'-120°54'-120°54'35°16'35°16'(a) Geologic Strip Map(b) AWD Line 204 Seismic Reflection Profile

^_DCPPLocation Map1:24,000Scale: 02,0004,0006,0008,000ft 01,0002,0003,000 mµNotes:- Line 204_AWD_FBM_psdm_1_mix_depth_tvfagc.sgy.

- See Figure 5-4 for an uninterpreted image of the seismic reflection line.

- Horizontal offsets are shown along a topographic profile above the seismic line.- Horizons are mapped as solid where confident, dashed where uncertain, and queried where poorly constrained.EXPLANATIONFault: solid where well located,dashed where approximately locatedTop of Monterey FormationTop of Obispo FormationTop of Rincon FormationTop of Mesozoic basementTmmTmoTmrKJfHorizontal distance alongseismic line, 2,000 ft increment2011 ONSIPPacific Gas and Electric CompanyPLATE 3(a) Geologic Strip Map and (b) AWDLine 204 Seismic Reflection ProfileMap projection and scale: WGS 84 / UTM Zone 10N,1:24,000Arrows marking offset ortruncated reflectors File path: S:\1005\034\QA_GIS\7_1_6_Report_Figures\Draft Report Figures\Plate_2_Line_103_104_AWD.mxd; Date: 06/26/2014; User: Jereme Chandler, LCI103-104PointBuchon5445333216324845426444296714 73618314852375238523010235419302122454745425741424844406536444434212010155115773846522434352820201718181723473614705418283429415255488080656042202730687048706460553880335770553235653515304565608072454536453030353540354830423560504830305450505058654555756035484525255580805020357045406525454030403045503035256230351610403545704420 85015704530257550255229352554456829455560357045452565304060455525405535326525403515552525213512303520243510185025302232252031252015154732152125182520293850502660252048302035253065DCPPMaino-Gonzales 1Pecho 1Spooner 1Montadoro 1CCWPechoS&T newQsQsTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoTmoKsKsKsQswQswQswQswQswQswQswQswQswQswQswQswQswQswQswQswQswKJfKJfafQlsQlsQlsQlsQlsQlsQlsQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmQmTmmTmmTmmTmmTmmTmmTmmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpmTmpeTmpeQalQalQalQalQalQalQalQalQalTmodTmodTmodTmodTmodTmodTmodTmodTmodQtQtTmrQafQafQafQeQeQeQeQeQeQeQeQeQes 02000400060008000100001200014000160001800020000220002400026000280003000032000340003600038000-120°54'-120°52'-120°52'35°20'35°20'35°18'35°18'35°16'35°16'35°14'35°14'35°11'35°11'(a) Geologic Strip Map(b) AWD Line 103-104 Seismic Reflection Profile

^_DCPPLocation Map1:24,000Scale: 02,0004,0006,000ft 01,0002,000 mµProjected parallelto axis of Anticline

²EXPLANATIONFault: solid where well located,dashed where approximately locatedTop of Monterey FormationTop of Obispo FormationTop of Rincon FormationTop of Mesozoic basementTmmTmoTmrKJfNotes:- Line 103-104_AWD_FBM_psdm_1_mix_depth_tvfagc.

- See Figure 5-2 for an uninterpreted image of the seismic reflection line.

- Horizontal offsets are shown along a topographic profile above the seismic line.

- Horizons are mapped as solid where confident, dashed where uncertain, and queried where poorly constrained.Horizontal distance alongseismic line, 2,000 ft incrementMap projection and scale: WGS 84 / UTM Zone 10N,1:24,000PLATE 2(a) Geologic Strip Map and (b) AWDLine 103-104 Seismic Reflection Profile2011 ONSIPPacific Gas and Electric CompanyArrows marking offset ortruncated reflectors