APPENDIX A SUPPLEMENTAL FIGURES

DCPPGSI-85-201PointSalUninterpreted(b)InterpretedFigure extentHosgri FaultNear Top Neogene UnconformityEarly Late Pliocene UnconformityTop Miocene UnconformityEXPLANATIONSeafloorFile Path: N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\mxd\Figure_A-1_GSILine_1985_201.mxd; Date: 07/27/2014; User: Bryan Bergkamp, Fugro; Rev. 3A-11980 GSI Line 201,Offshore Point SalOFFSHORE LESS STUDIESFigurePacific Gas and Electric Company DCPPW-22-79-2024Uninterpreted(b)InterpretedFigure extentHosgri FaultNear Top Neogene UnconformityEarly Late Pliocene UnconformityTop Miocene UnconformityEXPLANATIONSeafloorFile Path: N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\mxd\Figure_A-2_W-22-79-2024.mxd; Date: 07/27/2014; User: Bryan Bergkamp, Fugro; Rev. 3PointSalA-21979 Line W-22-2024,Offshore Point SalOFFSHORE LESS STUDIESFigurePacific Gas and Electric Company Pacific Gas and Electric CompanyFigure13701020PointSalInterpreted Inline 1370Interpreted Inline 1020Figure extentInlines 1370 and 1020 Showing Structure and Stratigraphy East and West of HFZ, Offshore Point SalA-3OFFSHORE LESS STUDIES(b)(a)EXPLANATIONNote: See Figure 6-27 for line location.SeafloorH10 unconformityH30 unconformityFaultChannel F marginsEarly Late Pliocene/ Near TopNeogene unconf. (ELP/NTN)Channel A marginsFile Path: N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\mxd\Figure_A-3_Line1370_1020.mxd; Date: 07/27/2014; User: Bryan Bergkamp, Fugro; Rev. 3 Pt. SalGSI 1985 Line SM-201 Showing Regional Structure Between HFZ and Casmalia Faults,OFFSHORE LESS STUDIESPacific Gas and Electric CompanyFigure extent 600.0 700.0 800.0 900.0 1000.01100.0 SP:0.000 0.250 0.500 0.750 1.000 1.250EXPLANATION Mapped inactive fault splay (Fugro Consultants, 2014)Top of bedrockTop Upper Pleistocene deposits(a) Uninterpreted (b) Interpreted2,000 m 600.0 700.0 800.0 900.0 1000.01100.0 SP:0.000 0.250 0.500 0.750 1.000 1.250Offshore Point Sal SW NE SW NEHosgri fault zone Mapped active fault splay (Fugro Consultants, 2014)Casmalia fault zoneA-4 FigureFilePath:N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\pdf\Figure-G-3-SM201.pdf;Date:07/17/2014;User:RobertDame,Fugro;Rev.3 Santa Maria River ValleyOFFSHORE LESS STUDIESPacific Gas and Electric CompanyLine SM-5A, Onshore Nipomo Mesa andEXPLANATION Mapped fault splay 2500.0 5000.0 7500.0 10000.0VibroseisLineSM-5A 12500.0 15000.0 SP: 0.200 0.400 0.600 0.800 1.000 1.200 1.400 1.600 1.800 2.000 2.200 2.400 2.600 2.8002,500m2,500m SE NW 2500.0 5000.0 7500.0 10000.0VibroseisLineSM-5A 12500.0 15000.0 SP: 0.200 0.400 0.600 0.800 1.000 1.200 1.400 1.600 1.800 2.000 2.200 2.400 2.600 2.800 SE NWOceanofault(b) Interpreted(a) UninterpretedTwo-WayTravelTime(Seconds)Two-WayTravelTime(Seconds)SantaMariaRiverfaultUnnamedfaultTop of bedrock Line SM-5AApproximate figure extentA-5 FigureFilePath:N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\pdf\Figure-G-5-SM-5A.pdf;Date:07/17/2014;User:RobertDame,Fugro;Rev.3Unnamedfault Point Sal Point San Luis Bedrock surface Bedrock surface Shoreline fault plane Shoreline fault plane Note: See Figures 7-22 and 7-24 for strandline locations and depth converted grid.

Bedrock channel I Bedrock channel IPacificGasandElectricCompanyFigure OFFSHORE LESS STUDIES A-6 File path: N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\ai\Figure_A-6_3D_Pa leoshoreline.ai; Date: 07/27/2014; User: Bryan Bergkamp, Fugro; Rev.3 3D Perspective View of Paleoshoreline and Bedrock Surface, San Luis Obispo Bay seconds Southern Extent Shoreline Fault nearGuadalupe, San Luis Obispo BayOFFSHORE LESS STUDIESA-7Pacific Gas and Electric Company FigureMap projection and scale: WGS 84 / UTM10NNote:TIFF image showing Guadalupe Oil Field Top Sisquoc Structure originally published by the California Division of Oil, Gas, and Geothermal Resources (1992).Santa Barbara CountySan Luis Obispo CountyShoreline faultCasmalia fault zoneApproximate extent of Figure G-8Guadalupe Oil FieldSouth Pecho faultFilePath:N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\pdf\Figure-G-7-Guadalupe.pdf;Date:07/17/2014;User:RobertDame,Fugro;Rev.3 Shoreline fault zonefault zoneSouth PechoPlan and Perspective View of Top ofSisquoc Formation and Shoreline FaultOFFSHORE LESS STUDIESA-8Pacific Gas and Electric Company Figurenear Guadalupe, San Luis Obispo BayMap projection and scale: WGS 84 / UTM10NNote:TIFF image showing Guadalupe Oil Field Top Sisquoc Structure originally published by the California Division of Oil, Gas, and Geothermal Resources (1992).B)Legend Fault (Dashed where Inferred)B)Onshore Oil/Gas Well County Boundary 260 0 2 60 0B)2700B)B)2800 20 90 0300 3100 2300B)24 002500 3000 0290B)B)2800B)2700(a) Plan view of top of Sisquoc Formation near Guadalupe(b) 3D perspective view of top of Sisquoc Formation near GuadalupeShoreline fault zoneFilePath:N:\Projects\04_2013\04_7922_4500_PGESeismicDataInterpretation\Outputs\2014_04_20_LESSStudiesRev3\pdf\Figure-G-8.pdf;Date:07/17/2014;User:RobertDame,Fugro;Rev.3